Certain Repairs / Replacement And Maintenance Of Street And Solar Light Poles, Feeder Pillar, Lt Ug Cable, Apfc Panel And Allied Works At Ins Dwarka Okha Under Ge Navy Porbandar, porbandar-Gujarat

Military Engineer Services-MES has published Certain Repairs / Replacement And Maintenance Of Street And Solar Light Poles, Feeder Pillar, Lt Ug Cable, Apfc Panel And Allied Works At Ins Dwarka Okha Under Ge Navy Porbandar. Submission Date for this Tender is 20-09-2022. Feeder Pillar Tenders in porbandar Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

33618407
Corrigendum : Certain Repairs / Replacement And Maintenance Of Street And Solar Light Poles, Feeder Pillar, Lt Ug Cable, Apfc Panel And Allied Works At Ins Dwarka Okha Under Ge Navy Porbandar
Open Tender
Indian
Gujarat
porbandar
20-09-2022

Tender Details

Certain Repairs / Replacement And Maintenance Of Street And Solar Light Poles, Feeder Pillar, Lt Ug Cable, Apfc Panel And Allied Works At Ins Dwarka Okha Under Ge Navy Porbandar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Sep-2022 Corrigendum BOQ 13-09-2022
2 13-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 76000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: CERTAIN REPAIRS / REPLACEMENT AND MAINTENANCE OF STREET AND SOLAR LIGHT POLES, FEEDER PILLER, LT UG CABLE, APFC PANEL AND ALLIED WORKS AT INS DWARKA OKHA UNDER GE NAVY PORBANDAR
Sl. No. Item Description
1PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundation of poles complete all as specified and directed.
2PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in foundation of poles complete all as specified and directed.
3PCC 1:2:4 type B-1 using (20mm graded crushed stone aggregate)in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, Benching, kneelers, apex stones, bed plates, kerbs, saucer drain(including finishing top surface of drain even and smooth without using extra cement), water troughs and the like including weathering, slightly rounded or chamfered angles and throating,and similar work including use & waste of necessary form work complete all as specified and as directed.
4Steel tubular swaged poles swan neck type complete with cast iron base plate, finial taper plug, Cap, mild steel bolts, nuts,screw, etc. type 410 SP-31(9.0 meters long) erected in vertical position embedded in PCC foundation strips 30cm wide each up to 1.5 Mtr height from top of coping fixed in repair / replacement complete all as specifiedand directed. Note :- Earth work, PCC for foundation and coping shall be measured and paid for separately.
5Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom,class 10 including removing old PCC pole fixed in repair / replacement complete all as specified and directed by Engr-in-charge.
6Painting to Prestressed concrete pole 9.0 meters long with two coats of synthetic enamel paint complete all as directed and specified.
7Painting to Steel tubular 9.0 meters long with one coat of rex oxide on pole and two coats of synthetic enamel paint complete all as directed and specified.
8Material and labour for numbering of pole no. using radium sticker of superier quality with back of Black round and fonts with white in colourcomplete all as specified and directed by Engineer-in-Charge.
9Pole street light bracket fabricated out of GI Tubing light grade 40 mm bore Bend to the shape as directed and of length 1.5mtr complete with mounting MS clamp of flat iron of suitable size 02 Nos incl nut bolts Etc of suitable size fixed in repair / replacement complete all as specified and directed by Engr In charge
10Hot press moulded SMC junction box 240mm x 130mm x 95mm (inside dimension) fixed with left side hinges and cable terminals with one number 6 Amp SP MCB fixed to pole with clamp nuts,bolts etc complete all as specified anddirected by Engineer-in-charge.
11Timer switches Digital type programmable for street light connected to contactor fixed in repair / replacement complete all as specified and directed.
12Power contactor 3 pole MCX-04suitable for street light connected to timerfixed in repair / replacement complete all as specified and as directed.
13MCB SPN 6-32 Amps,10 KA breaking capacity suitable for 230 V,50 Hz for lighting and other domestic load fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
14MCB TPN 32 Amps,10 KA breaking capacity suitable for 230 V,50 Hz for lighting and other domestic load fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
15MCB TPN 40 Amps,10 KA breaking capacity suitable for 230 V,50 Hz for lighting and other domestic load fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
16Building street light fitting 25W LED lamp 240 volts 50 Hz made up of pressure die-cast aluminium housing with high power LED as lighting source and lensseparate driver compartment with IP65 protection including taking down the u/s street light fittings fixed in repair / replacement complete all as specified and as directed.
17Solar street lights includingcleaning of solar panel, filling of distilled water for battery,charging battary and making servicable fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
18Battery 12 volts 80 AH capacity suitable of solar light fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
19LED Solar street light fitting 15 Watt including in built, lithium ion battery, solar panel, charge controller with dusk down sensor fixed in repair / replacement complete all as specified and directed.
20Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Glvanized earth plate connected with GI earth strip 25x4mm by means oflug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 32 mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover, fixed in repairs, including testing on completion complete all as specified and directed.
21LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp IP 65/66 protection complete in pole / post / wall position by connecting the electrical connection and tightening the nut,bolts and clamps and fixed in repair / replacement complete all as specified and directed.
22Flood light LED luminaire white 150 watt IP-65 flood light with highlighting architecturel facade highmast/basket ball court/squach court/batmittan court light fixed in repair / replacement complete all as specified and directed.
23Integral LED aviation luminaire light comprising of aluminium housing with polycarbonate enclosure complete in highmast light in position by connecting the electrical connection and tightening the nut,bolts and clamps fixed in repair / replacement complete all as specified and directed.
24Supply only Lug aluminium suitable cable size of 16 to 50 sqmm complete all as specified and directed Engineer-in-Charge.
25Supply only Lug aluminium suitable cable size of 70 to 150 sqmm complete all as specified and directed Engineer-in-Charge.
26Decorative gate light moon (opal) type made up of high grade unbreakeble polycarbonate material suitable for retrofit B22 base and 60 mm pole dia with 7 watt LED lamp fixed in repair / replacement complete all as specified and direcred by Engineer-in-Charge.
27Decorative gate light Lexo (Prismatic) made up of high grade unbreakeble polycorbonate material suitable B22 Base and 60 mm pole dia with 10 watt LED lamp fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
28New generation post top energy saving environmental friendly,long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LED as light sourse Coral (opal) - IP65 suitable for pole dia 76 mm with 25 watt LED lamp fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
29Garden light BGBOM 650 9W LED Bollards lightDie cast aluminium graphite grey powder coated GI Pipe Housing ,Mushroom shape opal acrylic diffuser if fixed in die-cast aluminium base for pleasant light output,LED mounted on die-cast aluminium base,IP-65, 240 Volt,Luminaire is provided with base plate and fixing holes for directely mounting on the concrete pedestal including including taking down the u/s street light fittings fixed in repair / replacement complete all as specified and as directed.
30Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, pipe line, cable,etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
31Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm deep as in soil complete all as specified and directed.
32Removing excavated material (soil/ rock) to distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point,complete all as specified and directed.
33Fine dry river sand cushion in trenches for cable protection with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Note :- Only compacted thickness will be measured and paid.
34Unreinforced precast concrete cable cover, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200Kg, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
35Galvanised tubing light grade 40 mm nominal bore for passing of cable, fixed to poles / walls / laying under floor/ roads complete with and including fittings, clamps nut boltsas required fixed in repair / replacement complete all as specified and as directed.
36Galvanised tubing light grade 50 mm nominal bore for passing of cable, fixed to poles / walls / laying under floor/ roads complete with and including fittings, clamps nut boltsas required fixed in repair / replacement complete all as specified and as directed.
37Galvanised tubing light grade 80 mm nominal bore for passing of cable, fixed to poles / walls / laying under floor/ roads complete with and including fittings, clamps nut boltsas required fixed in repair / replacement complete all as specified and as directed.
38Supply, install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric undergroundpower cablewith stranded aluminium conductor cross sectional area 16 sqmm 4 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
39Supply, install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric undergroundpower cablewith stranded aluminium conductor cross sectional area 25 sqmm 4 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
40Supply, install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric undergroundpower cablewith stranded aluminium conductor cross sectional area 50 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
41Supply, install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric undergroundpower cablewith stranded aluminium conductor cross sectional area 70 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
42Supply, install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric undergroundpower cablewith stranded aluminium conductor cross sectional area 95 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
43Supply, install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric undergroundpower cablewith stranded aluminium conductor cross sectional area 120 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
44Weather proof flat twin core 6 sqmm multistrand aluminium conductor cable fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
45Weather proof flat twin core 10 sqmm multistrand aluminium conductor cable fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
46PVC insulated 3 core 1.5 sqmm multistranded Copper conductor on pole for security light fromjunction boxto street light fititng including making necessary hole on surface of pole for insertion of 3 core pvc cable inside the pole upto street light fitting fixed in repair / replacement complete all as specified and directed.
47PVC insulated 3 core 2.5 sqmm multistranded Copper conductor on pole for security light fromjunction boxto street light fititng including making necessary hole on surface of pole for insertion of 3 core pvc cable inside the pole upto street light fitting fixed in repair / replacement complete all as specified and directed.
48PVC insulated 3 core 4.0 sqmm multistranded Copper conductor on pole for security light fromjunction boxto street light fititng including making necessary hole on surface of pole for insertion of 3 core pvc cable inside the pole upto street light fitting fixed in repair / replacement complete all as specified and directed.
49MCCB 4 pole 63 Amps, breaking capacity 25 KA, 415 Volts fixed thermal & magnetic releases, (Conforms to IEC:60947-II / IS:13947-II) fixed in repairs complete all as specified and as directed by Engineer-in-charge.
50MCCB 4 pole 100 Amps, breaking capacity 25 KA, 415 Volts, fixed thermal & magnetic releases, (Conforms to IEC:60947-II / IS:13947-II) fixed in repairs complete all as specified and as directed by Engineer-in-charge.
51MCCB 4 pole 160 Amps, breaking capacity 36 KA, 415 Volts, fixed thermal & magnetic releases, (Conforms to IEC:60947-II / IS:13947-II) fixed in repairs complete all as specified and as directed by Engineer-in-charge.
52MCCB 4 pole 250 Amps, breaking capacity 25 KA, 415 Volts, fixed thermal & magnetic releases, (Conforms to IEC:60947-II / IS:13947-II) fixed in repairs complete all as specified and as directed by Engineer-in-charge.
53MCCB 4 pole 400 Amps, breaking capacity 36 KA, 415 Volts, fixed thermal & magnetic releases, (Conforms to IEC:60947-II / IS:13947-II) fixed in repairs complete all as specified and as directed by Engineer-in-charge.
54Cable jointing kit for 1100 V (Earthed)grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 sqmm to 16 sqmm complete all as specified and directed Engr-in-Charge.
55Cable jointing kit for 1100 V (Earthed)grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified and directed Engr-in-Charge.
56Cable jointing kit for 1100 V (Earthed)grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 sqmm complete all as specified and directed Engr-in-Charge.
57LED Solar street light fitting 15 Watt with inbuilt solar charge controller with street light bracket suitable size including taking down the u/s solar light fittings fixed in repair / replacement compleate all as specified and as directed.
58MCB SPN 6-32Amps,10 KA breaking capacity 230 V,50 Hz for lighting and other domestic load fixed in repair / replacement complete all as specified and directed by Engineer - in - Charge.
59415V 10KA 63 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
60415V 10KA 40 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
61Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Galvanised earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 15mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion complete all as specified and directed.
62Onload change over switch 315 Amp four pole changeover, 415 Vac, 50 Hzby connecting the electrical connection andfixing on panal with nut, bolt, clamps fixed in repair / replacement complete all as specified and as directed by Engr-in-Charge.
63Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, CPRI approved manufactures having bus bar chamber with insulated Copper bus bar four wire system, colour coded for each phase of rating as per under for phase and neutral, insulated on epoxy type insulators. The panel shall be dust and vermin proof, IP-54 class protection and made 3.00 mm of outer body and inner body 2.00 mm thickCRCA MS sheet , powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm)including grouting of panel 30 cm above ground level by providing 60 cm long angle iron frame of size 40x40x5mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm fixed in repair / replacement complete all as specified and directed including the following accessories:- Make :- CPRI approved
64INCOMING :- (i)Thermal magnetic MCCB 4 pole,250 Amps 36 KA -01 No (ii) Copper bus bar 400 Amps with insulator-04 Nos (iii) Digital Voltmeter inbuilt selector switch, three phase Class 1= 01 No. (iv) Digital Ammeter square dial CT operated 96mmx96mm, three phase Class 1= 01 No (v) Instrument control fuses and indication lamp LED Type set of three– one setOUTGOING :- (i)Thermal magnetic MCCB 4 Pole 160 Amps 25 KA-02 Nos (ii) Thermal magneticMCCB 4 Pole ,100 Amps 25 KA-02 No (iii) Thermal magnetic MCCB 4 Pole 63 Amp 16 KA - 02 No(1 No for Spare) (iv)MCB TPN 63A- 04 Nos (v) Indication lamp LED Type set of three – one set
65Taking out panel door with old broken hinges and supply and fix with new MS hinges medium weight of 75mm long fix to panel & panel door with suitable nut & bolt /welding and Painting of LT panel with two coats of synthetic enamel paint of existing colour complete exc 5 sqm n exec 10 sqm complete all as specified and directed.
66Panel mounted volt meter digital type 3 phase as per existing fixed in repair / replacement complete all as specied and directed
67Panel mounted Ammeter digital type 3 phase as per existing fixed in repair / replacement complete all as specied and directed