Supply Installation Testing And Commissioning Of Electro Mechanical Equipments And Allied Civil Works For Wss Juhama- 1 Supply, Installation, Testing & Commissioning Of Open Well Pumping Units As Per 14220 At Filter Water Stage.Pump: -•Discharge: 5000, budgam-Jammu And Kashmir

Public Health Engineering Department-PHED has published Supply Installation Testing And Commissioning Of Electro Mechanical Equipments And Allied Civil Works For Wss Juhama- 1 Supply, Installation, Testing & Commissioning Of Open Well Pumping Units As Per 14220 At Filter Water Stage.Pump: -•Discharge: 5000. Submission Date for this Tender is 22-09-2022. Kitchen Equipment Tenders in budgam Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

33591595
Corrigendum : Supply Installation Testing And Commissioning Of Electro Mechanical Equipments And Allied Civil Works For Wss Juhama- 1 Supply, Installation, Testing & Commissioning Of Open Well Pumping Units As Per 14220 At Filter Water Stage.Pump: -•Discharge: 5000
Open Tender
Indian
Jammu And Kashmir
budgam
22-09-2022

Tender Details

Supply Installation Testing And Commissioning Of Electro Mechanical Equipments And Allied Civil Works For Wss Juhama- 1 Supply, Installation, Testing & Commissioning Of Open Well Pumping Units As Per 14220 At Filter Water Stage.Pump: -•Discharge: 5000Gphhead:78Mtrs ( Rest Technical Specifications As Per Annexure I ) 2 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. 3 S / I / T / C Of Suitable Size Of Gi Nipple For Pumping Equipment At Sr. No.01. The Nipple Shall Be Threaded One Side As Per Outlet Of Pump And Weld With Suitable Size Ms Flange As Per The Size Of The Rising Main / Pump Delive 4 Providing And Fitting Of 16 Sq.Mm 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. Make: L&T / Abb / Havells Or Equivalent 5 Fabrication, Providing And Fitting Of Modular Motor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories ( Rest Technical Specifications As Per Annexure I ) 6 Providing, Fitting, Testing And Commissioning Of 50Kva Voltage Stabilizer ( Rest Technical Specifications As Per Annexure I ) 7 Providing And Fitting Of 3.5-Core, 50Mm2 Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming Tois:7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. To Be Fitted From Change Over Panel To Modular Panel. The Job Also Includes P / F Of Aluminumthimbles Of Various Sizes As Per Size Requirement Including Crimping And Taping Make: L&T / Abb / Havells Or Equivalent 8 Providing / Supplying And Fitting Of 80Mm Dia G.I Flanged Rising Main At Site.The Pipe Shall Be Hot Dip Galvanized, Class C Confirming To Is 1239.The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make. Flanges ( As Per Is 6392 / 1997 Table: 17 ) Thickness Shall Conform Tois6392part1sttable-17.The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint. Welding Electrode Dc Arc Welding Using Welding Electrode Having Diameter Not Less Than 4Mm. Nuts And Bolts Nuts And Bolts ( Conforming To Is:1363 Part 1St ) Rubber Insertion Gaskets Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints.Make: Tata / Prakash / Surya / Jindal Or Equivalent 9 Fabrication / Providing / Fitting Of Delivery Manifold With Wash Out Arrangement Fabricated Out Of ( Class – C ) Gi Pipe 80 Mm And Welded With 18 Mm Thickms Flange As Per Table – 17 In Two Runs Of Welding . The Job Also Includes Cost On Account Of Suitable Size Nuts, Bolts And Rubber Packing In The Flanged Joints. The Job Also Includes ( 12 Mtrs ) Of Gi 80 Mm Pipe Arrangements Forfitmentincluding Bends, Reducers Etc For Fitment Of Pumping Equipment In The Sump 10 Providing And Fitting Of Ductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) 80Mm As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approvedfordrinkingwater ) .The Valve Shall Be Compatibleforburiedapplicationsandshallbesafetoinstall In Both Horizontal And Vertical Positions. It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve.Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.Sflangesperfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shall Be Fittedwithrising Main Of The Pumping Unit Atappropriatespotsaspersiterequirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job.Make: Vag / Kirloskar / Avk Or Equivalent 11 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves 80 Mm As Per Is14846 For Regulating The Water Supply Outside The Pumping Units.The Body And Bonnent Of The Valve Shall Be Of Ductile Iron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valveshallbecompatibleforburiedapplicationsandshallbe Safe To Install In Both Horizontal And Vertical Positions It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve. The Valve Shall Be Supplied Along With Hand Wheel. Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.Sflangesperfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shallbe Fittedwithrising Main Of The Pumping Unit Atappropriatespotsaspersiterequirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job.Make: Vag / Kirloskar / Avk Or Equivalent 12 Fabrication, Providing And Fitting Of Y- Junction Having 1M Length Of Each Arm To Be Fabricated Out Of Hot Dip Galvanized G.I, C-Class Pipe. The Job Also Includes Providing And Welding Of M.S Flanges To The Ends Of Each Arm. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint By Dint Of Dc Arc Welding. The Job Further Includes Providing And Fitting Of Nuts And Bolts ( Conforming To Is:1363 Part 1St ) And Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. The Size Of The Y- Junction Is Given Below : Dia Of The Pipe=80Mm ( Execution Of The Item Is Conditional To Site Requirement ) 13 Providing, Fitting, Testing And Commissioning Of Arv ( Air Release Valve ) As Per Is 14845 To Be Fitted To G.I Rising Main. The Arv Shall Have The Following Specifications: -Valve Type - Single Chamber, Single Orifice.Nominal Dia=50Mmend Connection - Flanged Ends To Is 1538 Working Temperature - 70Oc To 550 Ctest Pressure - Body / Seat 2.5 X Pnsealing Ring - Epdmconstruction -Ductile Iron With Stainless Steel Floats Coating - Epoxy With Corrosion Resistance Besides The Above Works, The Job Also Cost On Account Of P / F R.I Gasket, Nuts And Bolts Required For Installation Of Arv And Arrangement Of Gas Cutter / Welding Set At Site. Make: Vag / Kirloskar / Avk Or Equivalent 14 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded The Job Also Includes Painting Of Complete Structure In One Coat Of Red Oxide And 02 Coats Of Enamel Metal Paint.Vertical Posts=Ismc 200 No. Of Vertical Posts=02 Nos. Vertical Channel Section Each Post =02 Nos ( Seam Welded Face To Face ) . Vertical Post Bracing=Ismc 100 Sole / Matching Plates=500X300x12 Thickheight Of Vertical Posts=5 M Size Of Vertical Post Concrete Blocks=600X600x900 Mm ( Depth ) Concrete Grade=M20 Welding Electrode= Overcord Ss Of Adore / Esab / L&T / Advani Monorail Section=Ishb 250 Length Of Monorail=5M Steel Detail :Ismc 200I 5Mx2x2=20 M @ 22.3Kg / M = 446 Kgiiismc100 0.25Mx8x2x2=8 M@ 9.2Kg / M = 73.60 Kgiiiplate 0.500X0.300X8 ( 12Mmthk ) =1.20 M² ( 12Thk ) = 112.80 Kgivmonorail 5 M @ 51.4 Kg / M Ishb250=257Kgsv Bolts / Nuts ( L.S ) =30Kgs Total=919.4 Kg Say 920 Kg. 15 Providing, Installation Andtestingofmanualtypetriplespurgearchain Pulley Block Having Following Features:Gears:- The Hoist Shall Have Precision Machine Case Hardened Alloy Steel Gear Mountedonbearingsandhousedina Dustproofgearbox.Thelubrication Of Gears Should Be Of High Viscosity And Temperature For Longer Life Of Gears.Load Chain:- The Load Chain Be Made Of High Tensile Alloy Steel Having Wear Resistance And Greatest Mobility. The Chain Should Be Accurately Collaborated, Tested And Have Adequate In Built Factor Of Safety For Safer Operation.Load Chain Wheel:- The Load Chainwellshouldbedoubleballbearing Supportedandspeciallydesigned, Perfectlymachinedwheelproviding Correct Grip Of Load Chain To Makes The Hoist Most Safe And Reliable Against Any Failure. The Main Specifications Of C.P Block Are Given Below :Make = Pull Lift / Indef Or Equivalentcapacity = 2 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 M 16 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter Including Providing / Installation Of 12V, 180Ah Automotive Inverter Battery With Trolley And Cover. With 2-Core 4 Mm2 Cu ( 25 M ) Wiring As Per Site Requirement Along Withotheraccessorieslikess-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. Make = Exide / Luminous Or Equivalent 17 Electrification Of Pump House By Way Of P / F Of:-Lighting Points In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 9 W Led Lamps With Necessary Fixtures. – 08 Jobslighting Points, Bulk Head Type In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 9 W Led Lampwith Necessary Fixtures – 06 Jobsheating Points In 2.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 16 Amp. Ss Combine- 04 Jobs5-Pin Socket Points In 1.5 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit.- 04 Jobs Indicator Pointsin 1.0 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit – 04 Jobsceiling Fan With Regulator Switch, Wiring In 1.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. And Necessary Fixtures. – 02 Jobs Distribution Board Sp & N ( Regal Grey ) With 01 No Incoming And8 Way Outgoing, Fitted With Mini Mcb “C” Series 6A -04 No For Lighting Points And 2 / 3 Pin Socket Points And Fans, 10 A – 02 No For Flood Lights, 16 Amp – 02 No For Heating Points, 63 Amp Mcb ( Mains ) – Reputed Make. The Job Also Includes Supply Of 05Kw Sine Wave Voltage Stabilizer Single Phase 90 – 270 V Input For A Constant Output Of 240 V. The Fittings Shall Be Modular Type Of Reputed Make 18 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mmwide, Thickness3mmwith70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items.1 ) 3 Way Terminal Connector 20 Amp.2 ) 3 No Mcb 8 Amp.The Job Includes Fabrication, Providing And Fitting Of Three Arm Gi Structure At The Top Having 120° Angle Between Arms And Each Arm Having 15° Inclination With Respect To Horizontal Plane. Each Arm Should Be Of 2’ Length And Size And Shape Appropriate As Per Requirement Of The Luminary.The Job Also Includes Providing And Fitting Of Required Length Of Flexible Multi Strand 2 Mm Copper Wire From Each Terminal Connector To Each Holding Arm. The Pole Is Mounted On 1:2:4 Cement Concreting Of Size Not Less Than 2’X2’X6” ( Cost Of Concreting Not Included In The Job ) Using 04 No Anchor Bolts Of Required Size Not Less Than 7” In Length. The Complete Job Includes Earthing Ingi Electrode As Per Relevant Is Code 19 Providing, Installation, Testing And Commissioning Of Area Lighting120watt Led ( Street Light Type ) On Top Of Octagonal Pole Vide Item No.36Having Following Specs:Input: 90-240 V 50 Hzpower Factor: >0.9Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000Operating Temperature: -20°C To 60°Cthe Led Is Pressure Die Cast Aluminum Housing With Power Coated Finish And Having Ingress Protection Up To Ip-68.The Led Is Properly Fitted On The Arm Of The Pole And Connected To The Copperwire As Provided In The High Mast Polemake = Havells / L&T / Crompton Or Equivalent 20 Providing And Installation Of Junction Box With Dp 32 A Mcb To Serve As Main Switch For Led Lighting. The Job Includes Making Of Electric Connectionto The Circuit. 21 Providing And Carriage Of Tool Sets Comprising Of Following Items As Mentioned Below, For Day Today Maintenance Of Electro-Mechanical Equipment’S Installedat Water Supply Scheme. The Job Shall Include Cost On Account Of Carriage / Transportation Of Tool Set To Thewater Supply Scheme. The Tools Are To Be Provided In A Strong Tool Box With Key And Lock Mention Below Of Reputed Is Makei. Open End Spanner Of Size ( 4 / 5 To 30 / 32 ) ( 01 Complete Set ) Ii. Ring Type Spanner Of Size ( 4 / 5 To 30 / 32 ) ( 01 Complete Set ) Iii. Pliers, 9 Inch: ( 01 No ) Iv. Nose Pliers 9 Inch: ( 01No ) V.Screw Driver 12 Inch & 06 Inch: ( 01 No Each ) Vi.Hammer With Wooden Handle, I Kg ( 01 No ) Vii.Pipe Wrench 12 Inch: ( 01 No ) Viii Electric Multimeter =1No Ix. Digital Multimeter – 1No. X. Digital Clamp Tester Capable To Measure Up To 400A - 1 No. Xi. Hack Saw Frame With Hack Saw Blade – 01 No. Make = Taparia / Jhalani / Everest Or Equivalent 22 Supply, Installation Of 6 Kg Co2 Type Fire Extinguisher Manufactured As Per Is: 15683 Of 2006 With Is Mark And Comply With Dgms ( Approval ) . The Co2 Extinguisher Should Be Suitable For Class B & C Fire And Also For Fire Involving Electrical Equipment. The Cylinder Used For Fire Extinguisher Shall Be Approved By Petroleum And Explosive Safety Organization ( Peso ) As Per Gas Cylinder Rules 2004 And As Per Is: 7285 Of 2004. The Body Should Bemadeof Seamless Steel ( Manganese ) Confirming To Is: 7285 With Is Mark And Should Be Provided With Squeeze Grip Nozzle And Should Be Filled With Co2 Confirming To Is: 15222 Of 2002 With Certificate.The Extinguisher Shall Be Provided With Manufactures Test Certificate And Hydraulic Test Certificate By Bis From Peso. 23 Supply , Installation , Commissioning And Creation Of Pole Mounted, Outdoor Type 63Kvacapacitylevel-2 Electric Sub Station As Per The Technical Specifications Given Here Under-Specifications Conforming To Is: 1180 ( Part 1 ) 2014 With Latest Amendments. Type: Ht / Lt Transformertype Of Cooling: Onan. Operating Conditions:Input =11000 Voltsoutput =433 Volts Ac Supply In 3- Phase. Terminals:Input=3 No. Ht Bush Rods With Insulators, Washer, Nuts Etc. Output=4 No. Lt Bush Rods Switch Insulators, Washers, Nuts Etc.Core: The Core Shall Be Of High Permeability To Reduce Corelossesandthe Strips Shall Be Of Suitable Size And Gauge.Transformer Coils:Suitable Number Ofht And Lt Coils In Each Leg Ofthe Core. The Transformer Coils Shall Be Fabricated Out Of Superior Quality Aluminum Wire / Strips, Properly Wound. The Ht Transformer Is Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage, And All Leads And Lifts Involved.The Ht Transformer Shallbeofreputed Makefroman Iso Certifiedcompany As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Beprovidedwithbreatherfillwith Silica Jel Crystals, Conservator With Oil Level Indicator, Explosionvetand Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is: 1180 ( Part 1 ) 2014 With Latest Amendments.Note: The Scope Of The Work Shall Include Obtaining Of Necessaryinspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate. 24 Providing And Fitting G.I Channel / Angle / Flat Of Sizes Including Clamps ( For Transformer Bed, Taping Point , Brackets Of Poles Etc ) 25 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Of Ht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Ratedvoltage 11Kv 200A Complete As Per Is Specs ( 01 No. At Existing Tapping Point And Another At Existing Substation ) . 26 Supply, Installation, Testing And Commissioning Of 11Kv Polymer Fuses Sethorn Gap 3-Phase 200 A Suitable For Vertical Installation. 27 Supply, Installation, Testing And Commissioning Of Gapless Surge Arrestorstation Class, 10Ka, 9Kv, La With Polymer Housing, Station Type. 28 Supply And Fitting Of 11 Kv Polymeric Composite Pin / Discinsulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative , Creepage Distance 320Mm 29 Supply, Installation, Erection Of 9 Mtrs Long H.T Pole Of Specifications St-410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories .Wherever Required The Job Further Includes G.I Wire Earthing Of Pole As Per Rec Standard. 30 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement For Fitment Of Electric Substation, Poles Etc. 31 P / F Danger Plate With Clamps 32 Providing And Fixing G.I Barbed Wire For Anti-Climbing / Anti-Climbing Devices 33 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp , Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts , 2 N0- Turn Buckle , 1.8 M Long , 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.Istranded Wire Complete. 34 Painting Of Poles Red Oxide 10 No.S Poles 35 Painting Of Poles Aluminum Paint 10 Poles 36 P / L Of Acsr Conductor Of Size 0.05 As Per The Relevant Is Standard. 37 Providing And Fitting Of Anchoring Clamps Comprising Clamp Body , Plasticwedge, Steel Bill Bracket , Straps And Buckles Or Nuts And Bolts Required For Holding Of 3 – Core , 35 Sq. Mm H.T Ab Cable. 38 P / F Of 11 Kv Cable Termination Kit For Connecting 35 Sq Mm Xlpe Cable ( Abctype ) With The Existing Ht Line Near Tapping Point And Ht Transformer 39 Providing Andfittingofltdistributionboxforh.Ttransformerwithmccbfor Incomer And Sfu For Outgoing Circuits. 40 P / I Of Earthing Station For Electric Substation, Ltpanelandstabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Itemsrequired Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size : 80 Mm Dia , Length : 2000 Mmback Fill Compound : 30 Kg 41 Providing, Installation, Testing & Commissioning Of 415 ±10%V ( Output ) , 3 Phase 30Kva Air Cooled Cooled Diesel Generator Set As Per Is 8528 ( 2018 ) And Iso 3046 ( 2002 ) For Engine And Iec / Is 60034-1 For Alternator Suitably Assembled And Fitted In A Pollution Free Acoustic Enclosure / Canopy Of Required Size ( Rest Technical Specifications As Per Annexure I ) 42 Earth Work Inn Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc ( Not Exceeding 1.5M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5M, Including Getting Out Excavatedearth And Disposal Of Surplus Excavated Earth Asdirected. 43 Providing And Laying Of Soling Stone 44 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centering And Shattering. All Works Upto Plinth Level With 1:2:4 Mix ( 1 Cement, 2Cores Sand, 4 Graded Stone Aggregate 20Mm Nominal Size ) 45 Centering And Shattering Including Strutting, Propping Etc. And Removal Of From Work For Foundation, Footings, Base For Columns 46 Providing And Fitting Of L.T, 3.5Core , 50 Sqmm Cable To Work Up To 1.1 Kv , Xlpe Insulated , Galvanized Steel Strip Armored Almunium Cable Conforming To Is : 7098 ( Part -1 ) 1988 With Latest Amendments To Be Fitted From D.G Set To Modular Control Panel . The Job Includes Providing And Fitting Of Suitable Rating Copper Thimbles Duly Crimped And Taped At Conductor Ends By Hydraulic Crimping Tool. The Job Includes Earth Work In Excavation Whereverrequired For Laying Of Cable Underground.Make: L&T / Abb / Havells Or Equivalent 47 A ) Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’Siv ) Single Bed Warm Blankets With One Sided Fur- 02 No’Sthe Filling Material For Mattress, Quilt And Pillow Shall Be Of Goodquality Cottonb ) The Job Also Includes Providing Of Pressure Cooker 5Ltr 02 No’S, Steel Patella ( Utensil ) 5Ltrs 02 No’S, Cooking Heater 01 No., Room Heater 01 No., Steel Buckets 10 Litre Capacity 01 No., Plastic Bucket 10 Litre Capacity With Mug 02 No’S Each, Steel Glasses 06 No’S, Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermo- Cool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Godrej, Link Locks, 48 Providing Of 2 Kw Heat Convector For Operators For Winter Season 49 Fabrication Of 6’ X 6’ Angle Iron Bed By Way Of Providing And Fitting Of Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 50 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 No’S Including Cutting , Fixing All Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 51 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro- Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications:Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide. The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 52 Civil Works ( Sump ) 53 Earth Work In Excavation By Manual Means Over Areas Exceeding 30 Cms & Upto 5 M In Depth 1.5M In Width As Well As 10 Sqm. On Plan, Disposal Of Excavated Earth Upto 1 M, Disposed Earth To Be Levelled & Neatly Dressed ( All Kinds Of Soils ) 54 Providing & Laying Of Stone Soling ( Dully Hand Packed ) Including Watering Dressing And Ramming With All Carriages Loading Un-Loading And Stacking Etc Complete 55 Providing & Laying In Position Cement Concrete Of Specified Grade Excld. The Cost Of Centring And Shuttering All Work Upto Plinth Level ( 1:4:8 Coarse Sand 40 Mm Nominal Size Crushed Stone Agg. ) 56 P / L In Position Specified Grade Of Reinforced Cement Cencrete ( 1:1.5:3 ) Mix Excld. The Cost Of Centring, Shuttering, Finishing And Reinforecement- All Work Upto Plinth Level. With Stone Agg. 20Mm Nominal Size 57 Raft 58 Walls 59 P / L Of Reinforced Cement Concrete 1:1.5:3 Mix With 20-Mm Nominal Size Aggregates Including Curing But Excluding Cost Of Shuttering 60 Centring And Shuttering Incld. Strutting, Proping Etc & Removal Of Form Work For Founadtions, Footings, Bases Of Columns For Mass Concrete 61 Raft 62 Walls Internal And External 63 Suspended Floors 64 Edges Of Slabs 65 Reinforcement For Rcc Work Incld Straightning, Cutting, Bending, Placing In Position & Binding All Complete ( Thermo-Mechanically Treated Bars ) 66 P / L 12-Mm Thick Cement Plaster In 1:3 With Floating Coat Of Neat Cement 67 Brick Work For Superstructures In 1:6 Mix. 68 Extra For Brick Work For Superstructure. 69 Providing Wood Work For Doors And Windows ( 1St Clas Kail Wood ) . 70 Providing And Fixing Of Glazed Shutters 35Mm Thick. 71 Structural Steel Welded In Built Up Sections In Trusses, Frames, Wraught, Purlins Etc. 50X50x6mm 72 Cgi Sheet Roofing 0.63Mm Thick. 73 Finishing Walls With Water Proof Paint Applied @ 4.84Kg / 10 Sqm 74 Providing And Applying White Cement Based Putty Of Specified Thickness Of Approved Brand And Manufacture. ( 2Mm Thick ) 75 Painting With Synthetic Enamel Of Approved Brand And Manufacture ( Two Or More Coats ) . 76 Carriage Of Materails By Mech.Transport, From Source To Site Of Work 77 Sand / Stone Agg. For An Avg Lead Of 30 Km 78 Cement For An Avg Lead Of 05 Km 79 Steel For An Avg Lead Of 15 Km 80 Stone Soling For An Avg. Lead Of 30 Km

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Sep-2022 Corrigendum-I Date 22-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 95800.0 /-
Tender Value
INR 47.90 Lakhs /-