Supply Installation Testing And Commissioning Of Electro Mechanical Equipments And Allied Civil Works For Wss Dreygam- 1 Supply, Installation, Testing & Commissioning Of Open Well Pumping Units As Per 14220.Pump: -Discharge= 6000Gphhead = 73Mtrs ( Rest Technical Specifications As Per Annexure C ) 2 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. 3 S / I / T / C Of Suitable Size Of Gi Nipple For Pumping Equipment At Sr. No.01. The Nipple Shall Be Threaded One Side As Per Outlet Of Pump And Weld With Suitable Size Ms Flange As Per The Size Of The Rising Main / Pump Delive 4 Providing And Fitting Of 16 Sq.Mm 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. Make: L&T / Abb / Havells Or Equivalent 5 Fabrication, Providing And Fitting Of Modular Motor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories ( Rest Technical Specifications As Per Annexure C ) 6 Providing, Fitting, Testing And Commissioning Of 50Kva Voltage Stabilizer As Per Specifications Below:Capacity: 50Kvatype Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supply Multi Step.Type Of Regulator : Double Plate Type With Electrolytic Copper Contacts. Input Voltage : 150 Volts. ( 3 Phase ) Output Voltage : 400 ±10% Volts.Frequency : 50 ±3 C / S.Windings : Electrolytic Grade Copper Of Adequate Section, Vacuum Impregnated And Oven-Dried.Insulation : Fiber Glass Insulations To Tested Parameters. Cooling: Naturally, Oil Cooledtemp. Rise ( Max ) : 30°C Above Ambient Mounting : On Uni-Directional Wheels. Correction Rate : 30 Volts Per Step Wave Form Distortion : Virtually Nil Duty Cycle : 100% Continuous.Enclosure : Ms Sheet Enclosure In Pressed Cgr Sheet Powder Coated With Radiators. Core Laminates : High Grade, Low Eddy Loss, Grain Oriented Silicon Steel Laminations.Load : Three Phase Induction Motor Load. Load Amperes ( Continuous ) Overload In 24-Hours Operation: 10% Above Continuous Ampere Rating.The Voltage Stabilizer Shall Have T-Oil Levelindicatorgaugepreferablyglass Type Tube Or Otherwise Visible To Naked Eye. The Top Of The Container To Have A Display Panel For Housing 02 Numbers Digital Voltmeters ( 0-500V ) Along With 4-Way Selector Switch And Set Of Neon Indicators For Incoming And Outgoing Phases ( 06 No’S ) .Insulating Media ( T. Oil ) Of 11 Kva Grade To Be Provided And Filled Up To Top Level, With Dielectric Strength Of 5 Kv At 4Mm Air Gap. The T-Oil Of Specific Grade Should Be Provided In Separate Barrels And Filled At Site Up To Top Level. The Voltage Stabilizer Shall Be Accepted With Manufacturers Dully Stampedtest Certificate And Shall Have Name Plate With Specificationsmake : Ae / Servocon Or Equivalent 7 Providing And Fitting Of 3.5-Core, 50Mm2xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming Tois:7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. To Be Fitted From Change Over Panel To Modular Panel. The Job Also Includes P / F Of Aluminumthimbles Of Various Sizes As Per Size Requirement Including Crimping And Taping Make: L&T / Abb / Havells Or Equivalent 8 Providing / Supplying And Fitting Of 100Mm Dia G.I Flanged Rising Main At Site.The Pipe Shall Be Hot Dip Galvanized, Class C Confirming To Is 1239.The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make. Flanges ( As Per Is 6392 / 1997 Table: 17 ) Thickness Shall Conform Tois6392part1sttable-17.The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint. Welding Electrode Dc Arc Welding Using Welding Electrode Having Diameter Not Less Than 4Mm. Nuts And Bolts Nuts And Bolts ( Conforming To Is:1363 Part 1St ) Rubber Insertion Gaskets Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints.Make: Tata / Prakash / Surya / Jindal Or Equivalent 9 Fabrication / Providing / Fitting Of Delivery Manifold With Wash Out Arrangement Fabricated Out Of ( Class – C ) Gi Pipe 100 Mm And Welded With 18 Mm Thickms Flange As Per Table – 5 In Two Runs Of Welding . The Job Also Includes Cost On Account Of Suitable Size Nuts, Bolts And Rubber Packing In The Flanged Joints. The Job Also Includes ( 12 Mtrs ) Of Gi 80 Mm Pipe Arrangements Forfitmentincluding Bends, Reducers Etc For Fitment Of Pumping Equipment In The Sump 10 Providing And Fitting Of Ductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) 100Mm As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approvedfordrinkingwater ) .The Valve Shall Be Compatibleforburiedapplicationsandshallbesafetoinstall In Both Horizontal And Vertical Positions. It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve.Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.Sflangesperfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shall Be Fittedwithrising Main Of The Pumping Unit Atappropriatespotsaspersiterequirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job. Make: Vag / Kirloskar / Avk Or Equivalent 11 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves 100 Mm As Per Is14846 For Regulating The Water Supply Outside The Pumping Units.The Body And Bonnent Of The Valve Shall Be Of Ductile Iron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valveshallbecompatibleforburiedapplicationsandshallbe Safe To Install In Both Horizontal And Vertical Positions It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve. The Valve Shall Be Supplied Along With Hand Wheel. Cost On Account Of Nuts, Bolts, Gaskets, Etc Requiredfor The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.Sflangesperfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shallbe Fittedwithrising Main Of The Pumping Unit Atappropriatespotsaspersiterequirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job. Make: Vag / Kirloskar / Avk Or Equivalent 12 Fabrication, Providing And Fitting Of Y- Junction Having 1M Length Of Each Arm To Be Fabricated Out Of Hot Dip Galvanized G.I, C-Class Pipe. The Job Also Includes Providing And Welding Of M.S Flanges To The Ends Of Each Arm. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint By Dint Of Dc Arc Welding. The Job Further Includes Providing And Fitting Of Nuts And Bolts ( Conforming To Is:1363 Part 1St ) And Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. The Size Of The Y- Junction Is Given Below : Dia Of The Pipe=100Mm ( Execution Of The Item Is Conditional To Site Requirement ) 13 Providing, Fitting, Testing And Commissioning Of Arv ( Air Release Valve ) As Per Is 14845 To Be Fitted To G.I Rising Main. The Arv Shall Have The Following Specifications: -Valve Type - Single Chamber, Single Orifice.End Connection - Flanged Ends To Is 1538 Nominal Dia.-50Mmworking Temperature - 70Oc To 550 Ctest Pressure - Body / Seat 2.5 X Pnsealing Ring - Epdmconstruction -Ductile Iron With Stainless Steel Floats Coating - Epoxy With Corrosion Resistance Besides The Above Works, The Job Also Cost On Account Of P / F R.I Gasket, Nuts And Bolts Required For Installation Of Arv And Arrangement Of Gas Cutter / Welding Set At Site. Make: Vag / Kirloskar / Avk Or Equivalent 14 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded The Job Also Includes Painting Of Complete Structure In One Coat Of Red Oxide And 02 Coats Of Enamel Metal Paint.Vertical Posts=Ismc 200 No. Of Vertical Posts=02 Nos. Vertical Channel Section Each Post =02 Nos ( Seam Welded Face To Face ) . Vertical Post Bracing=Ismc 100 Sole / Matching Plates=500X300x12 Thickheight Of Vertical Posts=5 M Size Of Vertical Post Concrete Blocks=600X600x900 Mm ( Depth ) Concrete Grade=M20 Welding Electrode= Overcord Ss Of Adore / Esab / L&T / Advani Monorail Section=Ishb 250 Length Of Monorail=5M Steel Detail :Ismc 200I 5Mx2x2=20 M @ 22.3Kg / M = 446 Kgiiismc100 0.25Mx8x2x2=8 M@ 9.2Kg / M = 73.60 Kgiiiplate 0.500X0.300X8 ( 12Mmthk ) =1.20 M² ( 12Thk ) = 112.80 Kgivmonorail 5 M @ 51.4 Kg / M Ishb250=257Kgsv Bolts / Nuts ( L.S ) =30Kgs Total=919.4 Kg Say 920 Kg. 15 Providing, Installation Andtestingofmanualtypetriplespurgearchain Pulley Block Having Following Features:Gears:- The Hoist Shall Have Precision Machine Case Hardened Alloy Steel Gear Mountedonbearingsandhousedina Dustproofgearbox.Thelubrication Of Gears Should Be Of High Viscosity And Temperature For Longer Life Of Gears.Load Chain:- The Load Chain Be Made Of High Tensile Alloy Steel Having Wear Resistance And Greatest Mobility. The Chain Should Be Accurately Collaborated, Tested And Have Adequate In Built Factor Of Safety For Safer Operation.Load Chain Wheel:- The Load Chainwellshouldbedoubleballbearing Supportedandspeciallydesigned, Perfectlymachinedwheelproviding Correct Grip Of Load Chain To Makes The Hoist Most Safe And Reliable Against Any Failure. The Main Specifications Of C.P Block Are Given Below :Make = Pull Lift / Indef Or Equivalentcapacity = 2 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 M 16 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter Including Providing / Installation Of 12V, 180Ah Automotive Inverter Battery With Trolley And Cover. With 2-Core 4 Mm2 Cu ( 25 M ) Wiring As Per Site Requirement Along Withotheraccessorieslikess-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. Make = Exide / Luminous Or Equivalent 17 Electrification Of Pump House By Way Of P / F Of:-Lighting Points In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 9 W Led Lamps With Necessary Fixtures. – 08 Jobslighting Points, Bulk Head Type In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 9 W Led Lampwith Necessary Fixtures – 06 Jobsheating Points In 2.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 16 Amp. Ss Combine- 04 Jobs5-Pin Socket Points In 1.5 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit.- 04 Jobs Indicator Pointsin 1.0 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit – 04 Jobsceiling Fan With Regulator Switch, Wiring In 1.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. And Necessary Fixtures. – 02 Jobs Distribution Board Sp & N ( Regal Grey ) With 01 No Incoming And8 Way Outgoing, Fitted With Mini Mcb “C” Series 6A -04 No For Lighting Points And 2 / 3 Pin Socket Points And Fans, 10 A – 02 No For Flood Lights, 16 Amp – 02 No For Heating Points, 63 Amp Mcb ( Mains ) – Reputed Make. The Job Also Includes Supply Of 05Kw Sine Wave Voltage Stabilizer Single Phase 90 – 270 V Input For A Constant Output Of 240 V. The Fittings Shall Be Modular Type Of Reputed Make 18 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mmwide, Thickness3mmwith70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items.1 ) 3 Way Terminal Connector 20 Amp.2 ) 3 No Mcb 8 Amp.The Job Includes Fabrication, Providing And Fitting Of Three Arm Gi Structure At The Top Having 120° Angle Between Arms And Each Arm Having 15° Inclination With Respect To Horizontal Plane. Each Arm Should Be Of 2’ Length And Size And Shape Appropriate As Per Requirement Of The Luminary.The Job Also Includes Providing And Fitting Of Required Length Of Flexible Multi Strand 2 Mm Copper Wire From Each Terminal Connector To Each Holding Arm. The Pole Is Mounted On 1:2:4 Cement Concreting Of Size Not Less Than 2’X2’X6” ( Cost Of Concreting Not Included In The Job ) Using 04 No Anchor Bolts Of Required Size Not Less Than 7” In Length. The Complete Job Includes Earthing Ingi Electrode As Per Relevant Is Code 19 Providing, Installation, Testing And Commissioning Of Area Lighting120watt Led ( Street Light Type ) On Top Of Octagonal Pole Having Following Specs:Input: 90-240 V 50 Hzpower Factor: >0.9Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000Operating Temperature: -20°C To 60°Cthe Led Is Pressure Die Cast Aluminum Housing With Power Coated Finish And Having Ingress Protection Up To Ip-68.The Led Is Properly Fitted On The Arm Of The Pole And Connected To The Copperwire As Provided In The High Mast Pole Make = Havells / L&T / Crompton Or Equivalent 20 Providing And Installation Of Junction Box With Dp 32 A Mcb To Serve As Main Switch For Led Lighting. The Job Includes Making Of Electric Connectionto The Circuit. 21 Providing And Carriage Of Tool Sets Comprising Of Following Items As Mentioned Below, For Day Today Maintenance Of Electro-Mechanical Equipment’S Installedat Water Supply Scheme. The Job Shall Include Cost On Account Of Carriage / Transportation Of Tool Set To The Water Supply Scheme. The Tools Are To Be Provided In A Strong Tool Box With Key And Lock Mention Below Of Reputed Is Makei. Open End Spanner Of Size ( 4 / 5 To 30 / 32 ) ( 01 Complete Set ) Ii. Ring Type Spanner Of Size ( 4 / 5 To 30 / 32 ) ( 01 Complete Set ) Iii. Pliers, 9 Inch: ( 01 No ) Iv. Nose Pliers 9 Inch: ( 01No ) V.Screw Driver 12 Inch & 06 Inch: ( 01 No Each ) Vi.Hammer With Wooden Handle, I Kg ( 01 No ) Vii.Pipe Wrench 12 Inch: ( 01 No ) Viii Electric Multimeter =1No Ix. Digital Multimeter – 1No. X. Digital Clamp Tester Capable To Measure Up To 400A - 1 No. Xi. Hack Saw Frame With Hack Saw Blade – 01 No. Make = Taparia / Jhalani / Everest Or Equivalent 22 Supply, Installation Of 6 Kg Co2 Type Fire Extinguisher Manufactured As Per Is: 15683 Of 2006 With Is Mark And Comply With Dgms ( Approval ) . The Co2 Extinguisher Should Be Suitable For Class B & C Fire And Also For Fire Involving Electrical Equipment. The Cylinder Used For Fire Extinguisher Shall Be Approved By Petroleum And Explosive Safety Organization ( Peso ) As Per Gas Cylinder Rules 2004 And As Per Is: 7285 Of 2004. The Body Should Bemadeof Seamless Steel ( Manganese ) Confirming To Is: 7285 With Is Mark And Should Be Provided With Squeeze Grip Nozzle And Should Be Filled With Co2 Confirming To Is: 15222 Of 2002 With Certificate.The Extinguisher Shall Be Provided With Manufactures Test Certificate And Hydraulic Test Certificate By Bis From Peso. 23 Supply , Installation , Commissioning And Creation Of Pole Mounted, Outdoor Type 63Kvacapacitylevel-2 Electric Sub Station As Per The Technical Specifications Given Here Under-Specifications Conforming To Is: 1180 ( Part 1 ) 2014 With Latest Amendments. Type: Ht / Lt Transformertype Of Cooling: Onan. Operating Conditions:Input =11000 Voltsoutput =433 Volts Ac Supply In 3- Phase. Terminals:Input=3 No. Ht Bush Rods With Insulators, Washer, Nuts Etc. Output=4 No. Lt Bush Rods Switch Insulators, Washers, Nuts Etc.Core: The Core Shall Be Of High Permeability To Reduce Corelossesandthe Strips Shall Be Of Suitable Size And Gauge.Transformer Coils:Suitable Number Ofht And Lt Coils In Each Leg Ofthe Core. The Transformer Coils Shall Be Fabricated Out Of Superior Quality Aluminum Wire / Strips, Properly Wound. The Ht Transformer Is Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage, And All Leads And Lifts Involved.The Ht Transformer Shallbeofreputed Makefroman Iso Certifiedcompany As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Beprovidedwithbreatherfillwith Silica Jel Crystals, Conservator With Oil Level Indicator, Explosionvetand Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is: 1180 ( Part 1 ) 2014 With Latest Amendments.Note: The Scope Of The Work Shall Include Obtaining Of Necessaryinspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Onlyafter Obtaining Above Certificate. 24 Providing And Fitting G.I Channel / Angle / Flat Of Sizes Including Clamps ( For Transformer Bed, Taping Point , Brackets Of Poles Etc ) 25 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Of Ht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Ratedvoltage 11Kv 200A Complete As Per Is Specs ( 01 No. At Existing Tapping Point And Another At Existing Substation ) . 26 Supply, Installation, Testing And Commissioning Of 11Kv Polymer Fuses Sethorn Gap 3-Phase 200 A Suitable For Vertical Installation. 27 Supply, Installation, Testing And Commissioning Of Gapless Surge Arrestorstation Class, 10Ka, 9Kv, La With Polymer Housing, Station Type. 28 Supply And Fitting Of 11 Kv Polymeric Composite Pin Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative , Creepage Distance 320Mm 29 Supply, Installation, Erection Of 9 Mtrs Long H.T Pole Of Specifications St-410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories .Wherever Required The Job Further Includes G.I Wire Earthing Of Pole As Per Rec Standard. 30 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement For Fitment Of Electric Substation, Poles Etc. 31 P / F Danger Plate With Clamps 32 Providing And Fixing G.I Barbed Wire For Anti-Climbing / Anti-Climbing Devices 33 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp , Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts , 2 N0- Turn Buckle , 1.8 M Long , 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.Istranded Wire Complete. 34 Painting Of Poles Red Oxide 12 No.S Poles 35 Painting Of Poles Aluminum Paint 12 Poles 36 P / L Of Acsr Conductor Of Size 0.05 As Per The Relevant Is Standard. 37 Providing And Fitting Of Anchoring Clamps Comprising Clamp Body , Plasticwedge, Steel Bill Bracket , Straps And Buckles Or Nuts And Bolts Required For Holding Of 3 – Core , 35 Sq. Mm H.T Ab Cable. 38 P / F Of 11 Kv Cable Termination Kit For Connecting 35 Sq Mm Xlpe Cable ( Abctype ) With The Existing Ht Line Near Tapping Point And Ht Transformer 39 Providing Andfittingofltdistributionboxforh.Ttransformerwithmccbfor Incomer And Sfu For Outgoing Circuits. 40 P / I Of Earthing Station For Electric Substation, Ltpanelandstabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Itemsrequired Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size : 80 Mm Dia , Length : 2000 Mmback Fill Compound : 30 Kg 41 Providing, Installation, Testing & Commissioning Of 415 ±10%V ( Output ) , 3 Phase 50Kva Water Cooled Diesel Generator Set ( Rest Technical Specifications As Per Annexure C ) 42 Earth Work Inn Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc ( Not Exceeding 1.5M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5M, Including Getting Out Excavatedearth And Disposal Of Surplus Excavated Earth Asdirected. 43 Providing And Laying Of Soling Stone 44 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centering And Shattering. All Works Upto Plinth Level With 1:2:4 Mix ( 1 Cement, 2Cores Sand, 4 Graded Stone Aggregate 20Mm Nominal Size ) 45 Centering And Shattering Including Strutting, Propping Etc. And Removal Of From Work For Foundation, Footings, Base For Columns 46 Providing And Fitting Of L.T, 3.5 Core , 50Mm Sq. Capable To Work Up To 1.1 Kv , Xlpe Insulated , Galvanized Steel Strip Armoured Aluminium Cable Conforming To Is : 7098 ( Part -1 ) 1988 With Latest Amendments To Be Fitted From D.G Set To Modular Control Panel . The Job Includes Providing And Fitting Of Suitable Rating Copper Thimbles Duly Crimped And Taped At Conductor Ends By Hydraulic Crimping Tool. The Job Includes Earth Work In Excavation Wherever Required For Laying Of Cable Underground. Make: L&T / Abb / Havells Or Equivalent 47 A ) Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’Siv ) Single Bed Warm Blankets With One Sided Fur- 02 No’Sthe Filling Material For Mattress, Quilt And Pillow Shall Be Of Goodquality Cottonb ) The Job Also Includes Providing Of Pressure Cooker 5Ltr 02 No’S, Steel Patella ( Utensil ) 5Ltrs 02 No’S, Cooking Heater 01 No., Room Heater 01 No., Steel Buckets 10 Litre Capacity 01 No., Plastic Bucket 10 Litre Capacity With Mug 02 No’S Each, Steel Glasses 06 No’S, Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermo- Cool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Godrej, Link Locks, 48 Providing Of 2 Kw Heat Convector For Operators For Winter Season 49 Fabrication Of 6’ X 6’ Angle Iron Bed By Way Of Providing And Fitting Of Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 50 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 No’S Including Cutting , Fixing All Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 51 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro- Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications:Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide. The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 52 Civil Works Chowkidarquarter Cum Operator Room 53 Earth Work In Excavation By Mannual Means In Trenchesfor Foundation Drains, Pipes, Cables&Thelikenot Exceeding10sqmon Plan Including Disposal Of Excavated Earth Up To 50M And Lift Up To 1.5M, Disposed Soil To Be Neatly Dressed 54 Providing&Layingof Stonesoling ( Dullyhandpacked ) Including Watering Dressing And Ramming With All Carriages Loading Un-Loadingand Stacking Etc Complete 55 Providing&Layinginpositioncementconcreteofspecifiedgrade Excld. The Cost Of Centringandshutteringall Work Upto Plinthlevel ( 1:4:8 Coarse Sand 40 Mm Nominal Size Crushed Stone Agg. ) 56 Providingandlayinginposition Cementconcreteofspecifiedgrade Excludingthecostofcenteringand Shuttering.Allworkupto Plinth Levelin1:3:6 ( 1Cement:3Coarsesand:6Gradedstoneaggregate20mm Nominal Size ) . 57 Providing / Laying 50Mm Thick Dpc In 1:2:4 Mix Exculding Cost Of Formwork. 58 Supplyandfillinginplinthwithfinesandunderfloorsincludingwatering Raming, Consolidating And Dressing Complete. 59 P / L Of Cement Concrete Flooring 1:2:4 Finished With A Floating Coat Ofneat Cement Slurry And Curing Complete 50Mm Thick 60 Brickwork Withcomonburntclay ( Non-Modular ) Bricksofclass Designation7.5Infoundationinplinthincludingquarryincementmortar1:6 Mix 61 Extra For Brick Work In Superstructure Above Plinth Level Upto Floor Vlevel. 62 Providing / Layingof Reinforcedcementconcrete1:2:4Excluding Cost Of Form Work And Reinforcement Max. Size Of Graded Stone Agg.20Mm ( Crushed ) Nominal In Lintels, Beams And Suspended Floors. 63 Providing Wood Work In Framesof Doors, Windows And Cw Wroughtframed And Fixed In Position With Hold Fast Lugs In 1St Class Kail Wood. 64 Providingandfixingpanelledorpanelledandglazedshuttersfor Doorsandwindowsfixingwithbutthingesofrequiredsizewith Necessary Screw Excluding Panelling, Butt Hinges And Necessary Screws 35Mm Thick 1St Class Kail Wood. 65 Extra For Providing Panelling Or Glazing For Panelled / Glazed Shutters. 66 Providing / Fixing Wire Gauze Shutters Using Galvinized M.S Wire Gauze Of Average Width For Aperture 1.4Mm In Both Directions With Wire Dia 0.63Mm In 1St Class Kail Wood. 67 Providing And Fixing Glazed Shutters 35Mm Thick For Doors And Windows. 68 Providing / Fixing Of Flat Iron M.S Hold Fasts. 69 20Mm Thick Cement Plaster On Rough Side Of Brick Work In Cementmotar 1:4 70 15Mmthickcementplasteronfairsideofbrickworkincementmotar 1:4 71 Centering And Shuttering Including Strutting, Propping Etc Andremoval Of Same 72 Foundation / Plinth, 73 Beams , Lintels Sides And Base 74 Suspended Floors, Slab Ceiling, Room, Bath, Kitchen And Passage, Sofit, 75 Steelreinforcementforrccworkincludingstraightining, Cutting, Bending, Placing In Position And Binding All Complete. 76 Providingandapplyingpop / Wallputty2mmthickoverplastersurface To Prepare The Surface Even And Smooth. 77 Applying One Coat Of Cement Primer Of Approved Brand Andmanufacture For Exterior Surfaces. 78 Finishing Walls With Water Proofingcement Paint Of Approved Brandand Manufacture. 79 Distemperingwithoilbondwashabledistemperofapprovedbrandand Manufacture. 80 Applying Priming Coat Of Ready Mixed Primer Of Approved Brand Andmanufacture On Wood And Wood Based Surface. 81 Painting With Synthetic Enamel Paint Of Approved Brand Andmanufacture On Wood And Wood Based Surface. 82 Providing / Fixing M.S Grill Of Required Pattern In Frames Of Windowsand Cw. 83 Providing / Fixing Following Building Hardware Items Inlcuding Screwsetc. Anodized Aluminum Fittings. 84 100Mm Handles 85 125Mm Handles 86 200Mm Tower Bolts 87 100Mm Tower Bolts 88 250 X 16Mm Sliding Door Bolts 89 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 Over74mm Bed Of Dry Brick Blasts 40Mm Thick Nominal Size Well Ramed. 90 Filling Available Excavated Earth Back Into Trenches And Consolidation. 91 Providing Wood Work In Trusses, Purlins, Rafters Etc. Sawn And Fixed Inposition 1St Class Budloo Or Fir Wood 92 Providing Cgssheet Roofing With Polynercoatedjorlhooks, Bolts Andnuts8mmdiameterewithbitumenandg.Ilimpetwashersor Withg.Ilimpetwashersfilledwithwhiteleadincludingcoatof Approved Steel Primer And 2 Coats Of Approved Paint On Overlappings Of Sheets Complete. 0.63Mm Thick With Zinc Coating Not Less Than 275Grams / Sqm. 93 Providing Rides Or Hipes Of Width 60Cm Overall Width Plain Gs Sheetsincluding G.I Limpet Washers Filled With White Lead. 94 Providing / Fixing 20Mm Thick Wooden Planks Sealing Of Kail Wood. 95 Providing / Fixing 300 X 32Mm 1St Class Kail Wood Eves Boarding 96 Providingm.S.Lidwith50x 50X6mmangleironframe ( 0.75X1.00M ) And Lid Of 40 X 40 X 6Mm Frame And 30 X 6Mm Diagonals And 1Mm M.S Sheet. 97 Providing / Fixing Of Wc Indian Type Orissa Pattern With P Or S Trap Andlow Level Cistern 580 X 440Mm Size With Foot Rests Complete 98 Providing / Fixing Kitchen Sink 99 Providing / Fixing Bewelled Edge Mirror. 100 Providing / Fixing Floor Traps ( Lmr ) 101 Providing / Fixing Bends With Access Door. 102 100Mm Dia 103 75Mm Dia 104 Providing / Fixing Plain Bends 105 100Mm Dia 106 75Mm Dia 107 Providing / Fixing Double Equal Junctions 100Mm 108 Providing / Fixing Reducer 100 X 75Mm ( Lmr ) 109 Providing / Fixing Vent Pipe 75Mm 110 Providing / Fixing Cowel ( Lmr ) 111 Providing / Fixing Gratting With Jali. 112 Providing / Fixing Pvc Waist Pipe Flexible. 113 Providing / Fixing Holder Bat Clamps 114 100Mm Dia 115 75Mm Dia 116 Providing / Fixing Ball Cock ( Lmr ) 117 Providing / Fixing Pvc Manhole Covers With Frame0.30 X 0.30 118 Providing / Fixing Collars 119 100Mm Dia 120 75Mm Dia 121 Providing / Fixing Of Bib Taps C.P Brass 122 Providing / Fillingjointswithspunyarncementslurryandcementmortar 1:2 Mix 123 100Mm Dia 124 75Mm Dia 125 Providing / Fitting Of Gi Pipes With Gi Fittings. 126 Concealed 15Mm Dia 127 In Trenches 20Mm Dia 128 Providing / Fixing Of Pvc Connection Pipe 45Mm Long. 129 Providing / Placingofterrace ( Atallfloorlevels ) Polyethylenewater Storage Tank Isi 12701 Marked With Cover And Suitable Locking Arragements And Making Necessary Holes For Inlet Outlet Andoverflow Pipes But Without Fittings And Base Support. 130 Random Rubble Stone Masonry In 1:6 Mix. 131 Random Rubble Stone Masonry In Walls Laid Dry. 132 Providing / Fixing Ceremic Glazed Tiles. ( Floor / Wall ) 133 Carriage Ofmaterialsby Mechanical Transport Inlcludingloading And Unloading Etc Complete. 134 Stone Soling For An Average Lead Of 15Kms. 135 40Mm Stone Aggregate For An Average Lead Of 30Kms. 136 Sand & 20Mm Aggregate For An Average Lead Of 46Kms. 137 Cementfor An Average Lead Of 20Kms. 138 Steel For An Average Lead Of 20Kms. 139 Bricksfor An Average Lead Of 120Kms. 140 Carriage Ofmaterialsupto Site Of Work By Manual Labourinlcludingloading And Unloading Etc Complete For An Average Lead Of 400Mts. 141 Stone Soling 142 40Mm Stone Aggregate. 143 Sand / 20Mm Stone Aggregate 144 Cement 145 Steel 146 Bricks 147 Civil Works ( Construction Of Sump ) 148 Earth Work In Excavation By Manual Means Over Areas Exceeding 30 Cms & Upto 5 M In Depth 1.5M In Width As Well As 10 Sqm. On Plan, Disposal Of Excavated Earth Upto 1 M, Disposed Earth To Be Levelled & Neatly Dressed ( All Kinds Of Soils ) 149 Providing & Laying Of Stone Soling ( Dully Hand Packed ) Including Watering Dressing And Ramming With All Carriages Loading Un-Loading And Stackingetc Complete 150 Providing & Laying In Position Cement Concrete Of Specified Grade Excld. The Cost Of Centring And Shuttering All Work Upto Plinth Level ( 1:4:8 Coarse Sand 40 Mm Nominal Size Crushed Stone Agg. ) 151 P / L In Position Specified Grade Of Reinforced Cement Cencrete ( 1:1.5:3 ) Mix Excld. The Cost Of Centring, Shuttering, Finishing And Reinforecement- All Work Upto Plinth Level. With Stone Agg. 20Mm Nominal Size 152 Raft 153 Walls 154 Slab 155 Centring And Shuttering Incld. Strutting, Proping Etc & Removal Of Form Work For Founadtions, Footings, Bases Of Columns For Mass Concrete 156 Raft 157 Walls 158 Slab 159 Edges 160 Reinforcement For Rcc Work Incld Straightning, Cutting, Bending, Placing In Position & Binding All Complete ( Thermo-Mechanically Treated Bars ) 161 P / L 12-Mm Thick Cement Plaster In 1:3 162 Pumping Out Water Caused By Springs, Tidal Or River Seepage, Broken Water Mains Or Drains And The Like. 163 Structural Steel Work In Single Section Fixed With Connecting Plate Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Stee Steel Primer Completelid+Ladder 164 Close Timbering In Trenches Including Strutting, Shoring And Packing Cavities ( Wherever Required ) Complete. ( Measurements To Be Taken Of The Face Area Timbered ) . Depth Exceeding 1.5 M But Not Exceeding 3 M 165 Carriage Of Materials By Mech.Transport, From Source To Site Of Work 166 Sand / Stone Agg. For An Avg Lead Of 15 Km 167 Cement For An Avg Lead Of 15 Km 168 Stone Soling For An Avg. Lead Of 15 Km