Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #33591477

Supply Installation Testing And Commissioning Of Electro Mechanical Equipments And Allied Civil Works For Wss Mazhama-2 Supply, Installation, Testing & Commissioning Of Non-Clog Pumping Unit As Per Is 5600 At Raw Water Stage. Pump: - Type Of Pump :Non–

Issued by Government Departments · budgam, Jammu And Kashmir
Tender Value
1.37 Crore
Estimated cost
Bid Submission
22 Sep 2022
0 days left
EMD
2.74 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
budgam → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Installation Testing And Commissioning Of Electro Mechanical Equipments And Allied Civil Works For Wss Mazhama-2 Supply, Installation, Testing & Commissioning Of Non-Clog Pumping Unit As Per Is 5600 At Raw Water Stage. Pump: - Type Of Pump :Non–Clogopen Wellsubmersible Vertical Pump • Solid Handling Capacity: 20Mm ( Minimum ) / As Specified.• Quality Of Water:Raw Water To Be Handled -Discharge=15000Gph-Head=29Mtrs ( Rest Technical Specifications As Per Annexure F ) 3 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. 4 S / I / T / C Of Suitable Size Of Gi Nipple For Pumping Equipment At Sr. No.01. The Nipple Shall Be Threaded One Side As Per Outlet Of Pump And Weld With Suitable Size Ms Flange As Per The Size Of The Rising Main / Pump Delivery. 5 Providing And Fitting Of 16 Sq.Mm 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size.Make: L&T / Abb / Havells Or Equivalent 6 Fabrication, Providing And Fitting Of Modular Motor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories ( Rest Technical Specifications As Per Annexure F ) 7 Providing, Fitting, Testing And Commissioning Of 50Kva Voltage Stabilizer . ( Rest Technical Specifications As Per Annexure F ) 8 Providing And Fitting Of 3.5-Core, 50Mm2xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming Tois:7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. To Be Fitted From Change Over Panel To Modular Panel. The Job Also Includes P / F Of Aluminumthimbles Of Various Sizes As Per Size Requirement Including Crimping And Tapingmake: L&T / Abb / Havells Or Equivalent 9 Providing / Supplying And Fitting Of 150Mm Dia G.I Flanged Rising Main At Site.The Pipe Shall Be Hot Dip Galvanized, Class C Confirming To Is 1239.The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make. Flanges ( As Per Is 6392 / 1997 Table: 17 ) Thickness Shall Conform Tois6392part1sttable-17.The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint. Welding Electrode Dc Arc Welding Using Welding Electrode Having Diameter Not Less Than 4Mm. Nuts And Bolts Nuts And Bolts ( Conforming To Is:1363 Part 1St ) Rubber Insertion Gaskets Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints.Make: Tata / Prakash / Surya / Jindal Or Equivalent 10 Fabrication / Providing / Fitting Of Delivery Manifold With Wash Out Arrangement Fabricated Out Of ( Class – C ) Gi Pipe 150 Mm And Welded With 22 Mm Thickms Flange As Per Table – 17 In Two Runs Of Welding . The Job Also Includes Cost On Account Of Suitable Size Nuts, Bolts And Rubber Packing In The Flanged Joints. The Job Also Includes ( 12 Mtrs ) Of Gi 150 Mm Pipe Arrangements For Fitment Of Pumping Equipment In The Sump. 11 Providing And Fitting Of Ductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) 150Mm As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approvedfordrinkingwater ) .The Valve Shall Be Compatibleforburiedapplicationsandshallbesafetoinstall In Both Horizontal And Vertical Positions. It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve.Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.Sflangesperfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shall Be Fittedwithrising Main Of The Pumping Unit Atappropriatespotsaspersiterequirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job.Make: Vag / Kirloskar / Avk Or Equivalent 12 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves 150 Mm As Per Is14846 For Regulating The Water Supply Outside The Pumping Units.The Body And Bonnent Of The Valve Shall Be Of Ductile Iron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valveshallbecompatibleforburiedapplicationsandshallbe Safe To Install In Both Horizontal And Vertical Positions It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve. The Valve Shall Be Supplied Along With Hand Wheel. Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.Sflangesperfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shallbe Fittedwithrising Main Of The Pumping Unit Atappropriatespotsaspersiterequirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job. Make: Vag / Kirloskar / Avk Or Equivalent 13 Fabrication, Providing And Fitting Of Y- Junction Having 1M Length Of Each Arm To Be Fabricated Out Of Hot Dip Galvanized G.I, C-Class Pipe. The Job Also Includes Providing And Welding Of M.S Flanges To The Ends Of Each Arm. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint By Dint Of Dc Arc Welding. The Job Further Includes Providing And Fitting Of Nuts And Bolts ( Conforming To Is:1363 Part 1St ) And Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. The Size Of The Y- Junction Is Given Below : Dia Of The Pipe=150Mm 14 Providing, Fitting, Testing And Commissioning Of Arv ( Air Release Valve ) As Per Is 14845 To Be Fitted To G.I Rising Main. The Arv Shall Have The Following Specifications: -Valve Type - Single Chamber, Single Orifice.End Connection - Flanged Ends To Is 1538 Working Temperature - 70Oc To 550 Ctest Pressure - Body / Seat 2.5 X Pnsealing Ring - Epdmconstruction -Ductile Iron With Stainless Steel Floats Coating - Epoxy With Corrosion Resistance Besides The Above Works, The Job Also Cost On Account Of P / F R.I Gasket, Nuts And Bolts Required For Installation Of Arv And Arrangement Of Gas Cutter / Welding Set At Site. Make: Vag / Kirloskar / Avk Or Equivalent 15 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded The Job Also Includes Painting Of Complete Structure In One Coat Of Red Oxide And 02 Coats Of Enamel Metal Paint.Vertical Posts = Ismc 200No. Of Vertical Posts = 02 Nos.Vertical Channel Section Each Post = 02 Nos ( Seam Welded Face To Face ) .Vertical Post Bracing = Ismc 100Sole / Matching Plates = 500X300x12 Thickheight Of Vertical Posts = 5 Msize Of Vertical Post Concrete Blocks = 600X600x900 Mm ( Depth ) Concrete Grade = M20welding Electrode = Overcord Ss Of Adore / Esab / L&T / Advanimonorail Section = Ishb 250Length Of Monorail = 5Msteel Detail :I. Ismc 200 5Mx2x2 = 20 M @ 22.3Kg / M = 446 Kgii Ismc100 0.25Mx8x2x2 = 8 M@ 9.2Kg / M = 73.60 Kgiii Plate 0.500X0.300X8 ( 12Mmthk ) = 1.20 M² ( 12Thk ) = 112.80 Kgiv Monorail Ishb250 5 M @ 51.4 Kg / M = 257Kgsv Bolts / Nuts ( L.S ) = 30Kgs Total = 919.4 Kg Say 920 Kg. 16 Providing, Installation Andtestingofmanualtypetriplespurgearchain Pulley Block Having Following Features:Gears:- The Hoist Shall Have Precision Machine Case Hardened Alloy Steel Gear Mountedonbearingsandhousedina Dustproofgearbox.Thelubrication Of Gears Should Be Of High Viscosity And Temperature For Longer Life Of Gears.Load Chain:- The Load Chain Be Made Of High Tensile Alloy Steel Having Wear Resistance And Greatest Mobility. The Chain Should Be Accurately Collaborated, Tested And Have Adequate In Built Factor Of Safety For Safer Operation.Load Chain Wheel:- The Load Chainwellshouldbedoubleballbearing Supportedandspeciallydesigned, Perfectlymachinedwheelproviding Correct Grip Of Load Chain To Makes The Hoist Most Safe And Reliable Against Any Failure. The Main Specifications Of C.P Block Are Given Below :Make = Pull Lift / Indef Or Equivalent Capacity = 2 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 M 17 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover. With 2-Core 4 Mm2 Cu ( 25 M ) Wiring As Per Site Requirement Along Withotheraccessorieslikess-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item.Make = Exide / Luminous Or Equivalent 18 Electrification Of Pump House By Way Of P / F Of:-Lighting Points In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 9 W Led Lamps With Necessary Fixtures. – 08 Jobslighting Points, Bulk Head Type In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 9 W Led Lampwith Necessary Fixtures – 06 Jobsheating Points In 2.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 16 Amp. Ss Combine- 04 Jobs5-Pin Socket Points In 1.5 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit.- 04 Jobs Indicator Pointsin 1.0 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit – 04 Jobsceiling Fan With Regulator Switch, Wiring In 1.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. And Necessary Fixtures. – 02 Jobs Distribution Board Sp & N ( Regal Grey ) With 01 No Incoming And8 Way Outgoing, Fitted With Mini Mcb “C” Series 6A -04 No For Lighting Points And 2 / 3 Pin Socket Points And Fans, 10 A – 02 No For Flood Lights, 16 Amp – 02 No For Heating Points, 63 Amp Mcb ( Mains ) – Reputed Make. The Job Also Includes Supply Of 05Kw Sine Wave Voltage Stabilizer Single Phase 90 – 270 V Input For A Constant Output Of 240 V. The Fittings Shall Be Modular Type Of Reputed Make 19 Illumination Of Premises: Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mmwide, Thickness3mmwith70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items.3 Way Terminal Connector 20 Amp.3 No Mcb 8 Amp.The Job Includes Fabrication, Providing And Fitting Of Three Arm Gi Structure At The Top Having 120° Angle Between Arms And Each Arm Having 15° Inclination With Respect To Horizontal Plane. Each Arm Should Be Of 2’ Length And Size And Shape Appropriate As Per Requirement Of The Luminary.The Job Also Includes Providing And Fitting Of Required Length Of Flexible Multi Strand 2 Mm Copper Wire From Each Terminal Connector To Each Holding Arm. The Pole Is Mounted On 1:2:4 Cement Concreting Of Size Not Less Than 2’X2’X6” ( Cost Of Concreting Not Included In The Job ) Using 04 No Anchor Bolts Of Required Size Not Less Than 7” In Length. The Complete Job Includes Earthing In Gi Electrode As Per Relevant Is Code 20 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole Vide Item No.36Having Following Specs:Input: 90-240 V 50 Hzpower Factor: >0.9Colour Temperature: 4K - 6.5Kbeam Angle: 120° - 170°Lumens: >12000Operating Temperature: -20°C To 60°Cthe Led Is Pressure Die Cast Aluminum Housing With Power Coated Finish And Having Ingress Protection Up To Ip-68.The Led Is Properly Fitted On The Arm Of The Pole And Connected To The Copper Wire As Provided Inthe High Mast Pole Make = Havells / L&T / Crompton Or Equivalent 21 Providing And Installation Of Junction Box With Dp 32 A Mcb To Serve As Main Switch For Led Lighting. The Job Includes Making Of Electric Connection To The Circuit. 22 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer With Input Voltage 70-240 V And Output 220 V. The Stabilizer Shall Be Installed And Connected To The Electric Circuit As Per Location Provided By Site In Charge. 23 Providing And Carriage Of Tool Sets Comprising Of Following Items As Mentioned Below, For Day Today Maintenance Of Electro-Mechanical Equipment’S Installedat Water Supply Scheme. The Job Shall Include Cost On Account Of Carriage / Transportation Of Tool Set To Thewater Supply Scheme. The Tools Are To Be Provided In A Strong Tool Box With Key And Lock Mention Below Of Reputed Is Makei. Open End Spanner Of Size ( 4 / 5 To 30 / 32 ) ( 01 Complete Set ) Ii. Ring Type Spanner Of Size ( 4 / 5 To 30 / 32 ) ( 01 Complete Set ) Iii. Pliers, 9 Inch: ( 01 No ) Iv. Nose Pliers 9 Inch: ( 01No ) V.Screw Driver 12 Inch & 06 Inch: ( 01 No Each ) Vi.Hammer With Wooden Handle, I Kg ( 01 No ) Vii.Pipe Wrench 12 Inch: ( 01 No ) Viii Electric Multimeter =1No Ix. Digital Multimeter – 1No. X. Digital Clamp Tester Capable To Measure Up To 400A - 1 No. Xi. Hack Saw Frame With Hack Saw Blade – 01 No. Make = Taparia / Jhalani / Everest Or Equivalent 24 Supply, Installation Of 6 Kg Co2 Type Fire Extinguisher Manufactured As Per Is: 15683 Of 2006 With Is Mark And Comply With Dgms ( Approval ) . The Co2 Extinguisher Should Be Suitable For Class B & C Fire And Also For Fire Involving Electrical Equipment. The Cylinder Used For Fire Extinguisher Shall Be Approved By Petroleum And Explosive Safety Organization ( Peso ) As Per Gas Cylinder Rules 2004 And As Per Is: 7285 Of 2004. The Body Should Bemadeof Seamless Steel ( Manganese ) Confirming To Is: 7285 With Is Mark And Should Be Provided With Squeeze Grip Nozzle And Should Be Filled With Co2 Confirming To Is: 15222 Of 2002 With Certificate.The Extinguisher Shall Be Provided With Manufactures Test Certificate And Hydraulic Test Certificate By Bis From Peso. 25 Supply , Installation , Commissioning And Creation Of Pole Mounted, Outdoor Type Electric Sub Station As Per The Technical Specifications Given Here Under-Specifications Conforming To Is: 1180 ( Part 1 ) 2014 With Latest Amendments. Type: Ht / Lt Transformer Type Of Cooling: Onan. Operating Conditions:Capacity = 63Kva ( Level-2 ) Input =11000 Voltsoutput =433 Volts Ac Supply In 3- Phase. Terminals:Input=3 No. Ht Bush Rods With Insulators, Washer, Nuts Etc. Output=4 No. Lt Bush Rods Switch Insulators, Washers, Nuts Etc.Core: The Core Shall Be Of High Permeability To Reduce Core Losses And The Strips Shall Be Of Suitable Size And Gauge.Transformer Coils:Suitable Number Of Ht And Lt Coils In Each Leg Of The Core. The Transformer Coils Shall Be Fabricated Out Of Superior Quality Aluminum Wire / Strips, Properly Wound. The Ht Transformer Is Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage, And All Leads And Lifts Involved.The Ht Transformer Shallbeofreputed Makefroman Iso Certifiedcompany As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Beprovidedwithbreatherfillwith Silica Jel Crystals, Conservator With Oil Level Indicator, Explosionvetand Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is: 1180 ( Part 1 ) 2014 With Latest Amendments.Note: The Scope Of The Work Shall Include Obtaining Of Necessaryinspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate. 26 Providing And Fitting G.I Channel / Angle / Flat Of Sizes Including Clamps ( For Transformer Bed, Taping Point , Brackets Of Poles Etc ) 27 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Of Ht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 28 Supply, Installation, Testing And Commissioning Of 11Kv Polymer Fuses Set Horn Gap 3-Phase 200 A Suitable For Vertical Installation. 29 Supply, Installation, Testing And Commissioning Of Gapless Surge Arrestor Station Class, La With Polymer Housing, Station Type. 30 Supply And Fitting Of 11 Kv Polymeric Composite Pin / Disc Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative , Creep Age Distance 320Mm 31 Supply, Installation, Erection Of 9 Mtrs Long H.T Pope Of Specifications St-410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories .Wherever Required The Job Further Includes G.I Wire Earthing Of Pole As Per Rec Standard. 32 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement. ( For Fitment Of Electric Sub Station, Poles Etc ) 33 P / F Danger Plate With Clamps 34 Providing And Fixing G.I Barbed Wire For Anti-Climbing / Anti-Climbing Devices 35 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp , Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts , 2 N0- Turn Buckle , 1.8 M Long , 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.I Stranded Wire Complete. 36 Painting Of Poles Red Oxide For 19 Poles 37 Painting Of Poles Aluminum Paint For 19 Poles 38 Providing, Laying And Fitting Of Acsr Conductor As Per Relevant Is Standard 0.5 Acsr Conductor 39 Providing And Fitting Of Anchoring Clamps Comprising Clamp Body , Plastic Wedge, Steel Bill Bracket , Straps And Buckles Or Nuts And Bolts Required For Holding Of 3 – Core , 35 Sq. Mm H.T Ab Cable. 40 P / F Of 11 Kv Cable Termination Kit For Connecting 35Sq Mm Xlpe Cable ( Abc Type ) With The Existing Ht Line Near Tapping Point And Ht Transformer. 41 Providing Andfittingofltdistributionboxforh.Ttransformerwithmccb For Incomer And Sfu For Outgoing Circuits. 42 P / I Of Earthing Station For Electric Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size : 80 Mm Dia, Length : 2000 Mmback Fill Compound : 30 Kg 43 Providing, Installation, Testing & Commissioning Of 415 ±10%V ( Output ) , 3 Phase 40Kva Air Cooled Diesel Generator Set As Per Is 8528 ( 2018 ) For Engine And Iec / Is 60034-1 For Alternator Suitably Assembled And Fitted In A Pollution Free Acoustic Enclosure / Canopy Of Required Size ( Rest Technical Specifications As Per Annexure F ) 44 Earth Work Inn Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc ( Not Exceeding 1.5M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5M, Including Getting Out Excavatedearth And Disposal Of Surplus Excavated Earth Asdirected. 45 Providing And Laying Of Soling Stone 46 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centering And Shattering. All Works Upto Plinth Level With 1:2:4 Mix ( 1 Cement, 2Cores Sand, 4 Graded Stone Aggregate 20Mm Nominal Size ) 47 Centering And Shattering Including Strutting, Propping Etc. And Removal Of From Work For Foundation, Footings, Base For Columns 48 Providing And Fitting Of L.T, 3 Core , 50Mm Sq. Capable To Work Up To 1.1 Kv , Xlpe Insulated , Galvanized Steel Strip Armored Copper Cable Conforming To Is : 7098 ( Part -1 ) 1988 With Latest Amendments To Be Fitted From D.G Set To Modular Control Panel . The Job Includes Providing And Fitting Of Suitable Rating Copper Thimbles Duly Crimped And Taped At Conductor Ends By Hydraulic Crimping Tool. The Job Includes Earth Work In Excavation Whereverrequired For Laying Of Cable Underground. Make: L&T / Abb / Havells Or Equivalent 49 A ) Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’Siv ) Single Bed Warm Blankets With One Sided Fur- 02 No’Sthe Filling Material For Mattress, Quilt And Pillow Shall Be Of Good Quality Cottonb ) The Job Also Includes Providing Of Pressure Cooker 5Ltr 02 No’S, Steel Patella ( Utensil ) 5Ltrs 02 No’S, Cooking Heater 01 No., Room Heater 01 No., Steel Buckets 10 Litre Capacity 01 No., Plastic Bucket 10 Litre Capacity With Mug 02 No’S Each, Steel Glasses 06 No’S, Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermocool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Godrej, Link Locks, 50 Providing Of 2 Kw Heat Convector For Operators For Winter Season 51 Fabrication Of 6’ X 6’ Angle Iron Bed By Way Of Providing And Fitting Of Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 52 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 No’S Including Cutting , Fixing All Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 53 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro- Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide. The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 54 Stage 2Nd 55 Supply, Installation, Testing & Commissioning Of Open Well Pumping Units As Per 14220.Pump: - • Type Of Pump:Open Wellsubmersible Pump ( Vertical ) • Quality Of Water To Be Handled :Filter Water / Raw Water-Discharge:-20000 Gph-Head:- 30 Meter ( Rest Technical Specifications As Per Annexure F ) 56 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. 57 S / I / T / C Of Suitable Size Of Gi Nipple For Pumping Equipment At Sr. No.01. The Nipple Shall Be Threaded One Side As Per Outlet Of Pump And Weld With Suitable Size Ms Flange As Per The Size Of The Rising Main / Pump Delivery. 58 Providing And Fitting Of 16 Sq.Mm 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size.Make: L&T / Abb / Havells Or Equivalent 59 Fabrication, Providing And Fitting Of Modular Motor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories ( Rest Technical Specifications As Per Annexure F 60 Providing, Fitting, Testing And Commissioning Of 50Kva Voltage Stabilizer ( Rest Technical Specifications As Per Annexure F ) . 61 Providing And Fitting Of 3.5-Core, 50Mm2xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming Tois:7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. To Be Fitted From Change Over Panel To Modular Panel. The Job Also Includes P / F Of Aluminumthimbles Of Various Sizes As Per Size Requirement Including Crimping And Tapingmake: L&T / Abb / Havells Or Equivalent 62 Providing / Supplying And Fitting Of 150Mm Dia G.I Flanged Rising Main At Site.The Pipe Shall Be Hot Dip Galvanized, Class C Confirming To Is 1239.The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make. Flanges ( As Per Is 6392 / 1997 Table: 17 ) Thickness Shall Conform Tois6392part1sttable-17.The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint. Welding Electrode Dc Arc Welding Using Welding Electrode Having Diameter Not Less Than 4Mm. Nuts And Bolts Nuts And Bolts ( Conforming To Is:1363 Part 1St ) Rubber Insertion Gaskets Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. Make: Tata / Prakash / Surya / Jindal Or Equivalent 63 Fabrication / Providing / Fitting Of Delivery Manifold With Wash Out Arrangement Fabricated Out Of ( Class – C ) Gi Pipe 150 Mm And Welded With 22 Mm Thickms Flange As Per Table – 17 In Two Runs Of Welding . The Job Also Includes Cost On Account Of Suitable Size Nuts, Bolts And Rubber Packing In The Flanged Joints. The Job Also Includes ( 12 Mtrs ) Of Gi 150 Mm Pipe Arrangements For Fitment Of Pumping Equipment In The Sump. 64 Providing And Fitting Of Ductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) 150Mm As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approvedfordrinkingwater ) .The Valve Shall Be Compatibleforburiedapplicationsandshallbesafetoinstall In Both Horizontal And Vertical Positions. It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve.Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.Sflangesperfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shall Be Fittedwithrising Main Of The Pumping Unit Atappropriatespotsaspersiterequirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job.Make: Vag / Kirloskar / Avk Or Equivalent 65 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves 150 Mm As Per Is14846 For Regulating The Water Supply Outside The Pumping Units.The Body And Bonnent Of The Valve Shall Be Of Ductile Iron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valveshallbecompatibleforburiedapplicationsandshallbe Safe To Install In Both Horizontal And Vertical Positions It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve. The Valve Shall Be Supplied Along With Hand Wheel. Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.Sflangesperfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shallbe Fittedwithrising Main Of The Pumping Unit Atappropriatespotsaspersiterequirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job. Make: Vag / Kirloskar / Avk Or Equivalent 66 Fabrication, Providing And Fitting Of Y- Junction Having 1M Length Of Each Arm To Be Fabricated Out Of Hot Dip Galvanized G.I, C-Class Pipe. The Job Also Includes Providing And Welding Of M.S Flanges To The Ends Of Each Arm. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint By Dint Of Dc Arc Welding. The Job Further Includes Providing And Fitting Of Nuts And Bolts ( Conforming To Is:1363 Part 1St ) And Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. The Size Of The Y- Junction Is Given Below : Dia Of The Pipe=150Mm 67 Providing, Fitting, Testing And Commissioning Of Arv ( Air Release Valve ) As Per Is 14845 To Be Fitted To G.I Rising Main. The Arv Shall Have The Following Specifications: -Valve Type - Single Chamber, Single Orifice.Nominal Dia=50Mmend Connection - Flanged Ends To Is 1538 Working Temperature - 70Oc To 550 Ctest Pressure - Body / Seat 2.5 X Pnsealing Ring - Epdmconstruction -Ductile Iron With Stainless Steel Floats Coating - Epoxy With Corrosion Resistance Besides The Above Works, The Job Also Cost On Account Of P / F R.I Gasket, Nuts And Bolts Required For Installation Of Arv And Arrangement Of Gas Cutter / Welding Set At Site. Make: Vag / Kirloskar / Avk Or Equivalent 68 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded The Job Also Includes Painting Of Complete Structure In One Coat Of Red Oxide And 02 Coats Of Enamel Metal Paint.Vertical Posts = Ismc 200No. Of Vertical Posts = 02 Nos.Vertical Channel Section Each Post = 02 Nos ( Seam Welded Face To Face ) .Vertical Post Bracing = Ismc 100Sole / Matching Plates = 500X300x12 Thickheight Of Vertical Posts = 5 Msize Of Vertical Post Concrete Blocks = 600X600x900 Mm ( Depth ) Concrete Grade = M20welding Electrode = Overcord Ss Of Adore / Esab / L&T / Advanimonorail Section = Ishb 250Length Of Monorail = 5Msteel Detail :I. Ismc 200 5Mx2x2 = 20 M @ 22.3Kg / M = 446 Kgii Ismc100 0.25Mx8x2x2 = 8 M@ 9.2Kg / M = 73.60 Kgiii Plate 0.500X0.300X8 ( 12Mmthk ) = 1.20 M² ( 12Thk ) = 112.80 Kgiv Monorail Ishb250 5 M @ 51.4 Kg / M = 257Kgsv Bolts / Nuts ( L.S ) = 30Kgs Total = 919.4 Kg Say 920 Kg. 69 Providing, Installation Andtestingofmanualtypetriplespurgearchain Pulley Block Having Following Features:Gears:- The Hoist Shall Have Precision Machine Case Hardened Alloy Steel Gear Mountedonbearingsandhousedina Dustproofgearbox.Thelubrication Of Gears Should Be Of High Viscosity And Temperature For Longer Life Of Gears.Load Chain:- The Load Chain Be Made Of High Tensile Alloy Steel Having Wear Resistance And Greatest Mobility. The Chain Should Be Accurately Collaborated, Tested And Have Adequate In Built Factor Of Safety For Safer Operation.Load Chain Wheel:- The Load Chainwellshouldbedoubleballbearing Supportedandspeciallydesigned, Perfectlymachinedwheelproviding Correct Grip Of Load Chain To Makes The Hoist Most Safe And Reliable Against Any Failure. The Main Specifications Of C.P Block Are Given Below :Make = Pull Lift / Indef Or Equivalentcapacity = 2 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 M 70 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover. With 2-Core 4 Mm2 Cu ( 25 M ) Wiring As Per Site Requirement Along Withotheraccessorieslikess-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item.Make = Exide / Luminous Or Equivalent 71 Electrification Of Pump House By Way Of P / F Of:-Lighting Points In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 9 W Led Lamps With Necessary Fixtures. – 08 Jobslighting Points, Bulk Head Type In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 9 W Led Lampwith Necessary Fixtures – 06 Jobsheating Points In 2.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 16 Amp. Ss Combine- 04 Jobs5-Pin Socket Points In 1.5 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit.- 04 Jobs Indicator Pointsin 1.0 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit – 04 Jobsceiling Fan With Regulator Switch, Wiring In 1.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. And Necessary Fixtures. – 02 Jobs Distribution Board Sp & N ( Regal Grey ) With 01 No Incoming And8 Way Outgoing, Fitted With Mini Mcb “C” Series 6A -04 No For Lighting Points And 2 / 3 Pin Socket Points And Fans, 10 A – 02 No For Flood Lights, 16 Amp – 02 No For Heating Points, 63 Amp Mcb ( Mains ) – Reputed Make. The Job Also Includes Supply Of 05Kw Sine Wave Voltage Stabilizer Single Phase 90 – 270 V Input For A Constant Output Of 240 V. The Fittings Shall Be Modular Type Of Reputed Make 72 Illumination Of Premises: Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mmwide, Thickness3mmwith70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items.3 Way Terminal Connector 20 Amp.3 No Mcb 8 Amp.The Job Includes Fabrication, Providing And Fitting Of Three Arm Gi Structure At The Top Having 120° Angle Between Arms And Each Arm Having 15° Inclination With Respect To Horizontal Plane. Each Arm Should Be Of 2’ Length And Size And Shape Appropriate As Per Requirement Of The Luminary.The Job Also Includes Providing And Fitting Of Required Length Of Flexible Multi Strand 2 Mm Copper Wire From Each Terminal Connector To Each Holding Arm. The Pole Is Mounted On 1:2:4 Cement Concreting Of Size Not Less Than 2’X2’X6” ( Cost Of Concreting Not Included In The Job ) Using 04 No Anchor Bolts Of Required Size Not Less Than 7” In Length. The Complete Job Includes Earthing In Gi Electrode As Per Relevant Is Code 73 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole Vide Item No.36Having Following Specs:Input: 90-240 V 50 Hzpower Factor: >0.9Colour Temperature: 4K - 6.5Kbeam Angle: 120° - 170°Lumens: >12000Operating Temperature: -20°C To 60°Cthe Led Is Pressure Die Cast Aluminum Housing With Power Coated Finish And Having Ingress Protection Up To Ip-68.The Led Is Properly Fitted On The Arm Of The Pole And Connected To The Copper Wire As Provided Inthe High Mast Pole Make = Havells / L&T / Crompton Or Equivalent 74 Providing And Installation Of Junction Box With Dp 32 A Mcb To Serve As Main Switch For Led Lighting. The Job Includes Making Of Electric Connection To The Circuit. 75 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer With Input Voltage 70-240 V And Output 220 V. The Stabilizer Shall Be Installed And Connected To The Electric Circuit As Per Location Provided By Site In Charge. 76 Providing And Carriage Of Tool Sets Comprising Of Following Items As Mentioned Below, For Day Today Maintenance Of Electro-Mechanical Equipment’S Installedat Water Supply Scheme. The Job Shall Include Cost On Account Of Carriage / Transportation Of Tool Set To Thewater Supply Scheme. The Tools Are To Be Provided In A Strong Tool Box With Key And Lock Mention Below Of Reputed Is Makei. Open End Spanner Of Size ( 4 / 5 To 30 / 32 ) ( 01 Complete Set ) Ii. Ring Type Spanner Of Size ( 4 / 5 To 30 / 32 ) ( 01 Complete Set ) Iii. Pliers, 9 Inch: ( 01 No ) Iv. Nose Pliers 9 Inch: ( 01No ) V.Screw Driver 12 Inch & 06 Inch: ( 01 No Each ) Vi.Hammer With Wooden Handle, I Kg ( 01 No ) Vii.Pipe Wrench 12 Inch: ( 01 No ) Viii Electric Multimeter =1No Ix. Digital Multimeter – 1No. X. Digital Clamp Tester Capable To Measure Up To 400A - 1 No. Xi. Hack Saw Frame With Hack Saw Blade – 01 No. Make = Taparia / Jhalani / Everest Or Equivalent 77 Supply, Installation Of 6 Kg Co2 Type Fire Extinguisher Manufactured As Per Is: 15683 Of 2006 With Is Mark And Comply With Dgms ( Approval ) . The Co2 Extinguisher Should Be Suitable For Class B & C Fire And Also For Fire Involving Electrical Equipment. The Cylinder Used For Fire Extinguisher Shall Be Approved By Petroleum And Explosive Safety Organization ( Peso ) As Per Gas Cylinder Rules 2004 And As Per Is: 7285 Of 2004. The Body Should Bemadeof Seamless Steel ( Manganese ) Confirming To Is: 7285 With Is Mark And Should Be Provided With Squeeze Grip Nozzle And Should Be Filled With Co2 Confirming To Is: 15222 Of 2002 With Certificate.The Extinguisher Shall Be Provided With Manufactures Test Certificate And Hydraulic Test Certificate By Bis From Peso. 78 Supply , Installation , Commissioning And Creation Of Pole Mounted, Outdoor Type Electric Sub Station As Per The Technical Specifications Given Here Under-Specifications Conforming To Is: 1180 ( Part 1 ) 2014 With Latest Amendments. Type: Ht / Lt Transformer Type Of Cooling: Onan. Operating Conditions:Capacity = 100Kva ( Level-2 ) Input =11000 Voltsoutput =433 Volts Ac Supply In 3- Phase. Terminals:Input=3 No. Ht Bush Rods With Insulators, Washer, Nuts Etc. Output=4 No. Lt Bush Rods Switch Insulators, Washers, Nuts Etc.Core: The Core Shall Be Of High Permeability To Reduce Core Losses And The Strips Shall Be Of Suitable Size And Gauge.Transformer Coils:Suitable Number Of Ht And Lt Coils In Each Leg Of The Core. The Transformer Coils Shall Be Fabricated Out Of Superior Quality Aluminum Wire / Strips, Properly Wound. The Ht Transformer Is Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage, And All Leads And Lifts Involved.The Ht Transformer Shallbeofreputed Makefroman Iso Certifiedcompany As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Beprovidedwithbreatherfillwith Silica Jel Crystals, Conservator With Oil Level Indicator, Explosionvetand Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is: 1180 ( Part 1 ) 2014 With Latest Amendments.Note: The Scope Of The Work Shall Include Obtaining Of Necessaryinspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate. 79 Providing And Fitting G.I Channel / Angle / Flat Of Sizes Including Clamps ( For Transformer Bed, Taping Point , Brackets Of Poles Etc ) 80 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Of Ht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 81 Supply, Installation, Testing And Commissioning Of 11Kv Polymer Fuses Set Horn Gap 3-Phase 200 A Suitable For Vertical Installation. 82 Supply, Installation, Testing And Commissioning Of Gapless Surge Arrestor Station Class, La With Polymer Housing, Station Type. 83 Supply And Fitting Of 11 Kv Polymeric Composite Pin / Disc Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative , Creep Age Distance 320Mm 84 Supply, Installation, Erection Of 9 Mtrs Long H.T Pope Of Specifications St-410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories .Wherever Required The Job Further Includes G.I Wire Earthing Of Pole As Per Rec Standard. 85 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement. ( For Fitment Of Electric Sub Station, Poles Etc ) 86 P / F Danger Plate With Clamps 87 Providing And Fixing G.I Barbed Wire For Anti-Climbing / Anti-Climbing Devices 88 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp , Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts , 2 N0- Turn Buckle , 1.8 M Long , 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.I Stranded Wire Complete. 89 Painting Of Poles Red Oxide For 03 Poles 90 Painting Of Poles Aluminum Paint For 03 Poles 91 Providing, Laying And Fitting Of Acsr Conductor As Per Relevant Is Standard 0.5 Acsr Conductor 92 Providing And Fitting Of Anchoring Clamps Comprising Clamp Body , Plastic Wedge, Steel Bill Bracket , Straps And Buckles Or Nuts And Bolts Required For Holding Of 3 – Core , 35 Sq. Mm H.T Ab Cable. 93 P / F Of 11 Kv Cable Termination Kit For Connecting 35Sq Mm Xlpe Cable ( Abc Type ) With The Existing Ht Line Near Tapping Point And Ht Transformer. 94 Providing Andfittingofltdistributionboxforh.Ttransformerwithmccb For Incomer And Sfu For Outgoing Circuits. 95 P / I Of Earthing Station For Electric Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size : 80 Mm Dia, Length : 2000 Mmback Fill Compound : 30 Kg 96 Providing, Installation, Testing & Commissioning Of 415 ±10%V ( Output ) , 3 Phase Water Cooled 50Kvadiesel Generator Set As Per Is 8528 ( 2018 ) And Iso:3046 ( 2002 ) For Engine And Iec / Is 60034-1 For Alternator Suitably Assembled And Fitted In A Pollution Free Acoustic Enclosure / Canopy Of Required Size. ( Rest Technical Specifications As Per Annexure F ) 97 Earth Work Inn Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc ( Not Exceeding 1.5M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5M, Including Getting Out Excavatedearth And Disposal Of Surplus Excavated Earth Asdirected. 98 Providing And Laying Of Soling Stone 99 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centering And Shattering. All Works Upto Plinth Level With 1:2:4 Mix ( 1 Cement, 2Cores Sand, 4 Graded Stone Aggregate 20Mm Nominal Size ) 100 Centering And Shattering Including Strutting, Propping Etc. And Removal Of From Work For Foundation, Footings, Base For Columns 101 Providing And Fitting Of L.T, 3 Core , 50Mm Sq. Capable To Work Up To 1.1 Kv , Xlpe Insulated , Galvanized Steel Strip Armored Copper Cable Conforming To Is : 7098 ( Part -1 ) 1988 With Latest Amendments To Be Fitted From D.G Set To Modular Control Panel . The Job Includes Providing And Fitting Of Suitable Rating Copper Thimbles Duly Crimped And Taped At Conductor Ends By Hydraulic Crimping Tool. The Job Includes Earth Work In Excavation Whereverrequired For Laying Of Cable Underground.Make: L&T / Abb / Havells Or Equivalent 102 A ) Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’Siv ) Single Bed Warm Blankets With One Sided Fur- 02 No’Sthe Filling Material For Mattress, Quilt And Pillow Shall Be Of Good Quality Cottonb ) The Job Also Includes Providing Of Pressure Cooker 5Ltr 02 No’S, Steel Patella ( Utensil ) 5Ltrs 02 No’S, Cooking Heater 01 No., Room Heater 01 No., Steel Buckets 10 Litre Capacity 01 No., Plastic Bucket 10 Litre Capacity With Mug 02 No’S Each, Steel Glasses 06 No’S, Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermocool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Godrej, Link Locks, 103 Providing Of 2 Kw Heat Convector For Operators For Winter Season 104 Fabrication Of 6’ X 6’ Angle Iron Bed By Way Of Providing And Fitting Of Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 105 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 No’S Including Cutting , Fixing All Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 106 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro- Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications:Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide. The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 107 Civil Works ( Operator Quarter ) 108 Earthworkinexcavationbymannualmeansintrenches Forfoundation Drains, Pipes, Cables&Thelikenotexceeding10sqmonplanincluding Disposal Of Excavated Earth Up To 50M And Lift Up To 1.5 M, Disposed Soil To Be Neatly Dressed 109 Providing &Layingof Stone Soling ( Dully Handpacked ) Includingwatering Dressing And Ramming With All Carriages Loading Un-Loading And Stacking Etccomplete 110 Providing&Layinginpositioncementconcreteofspecifiedgradeexcld.The Cost Of Centring And Shuttering All Work Upto Plinth Level ( 1:4:8 Coarse Sand 40 Mm Nominal Size Crushed Stone Agg. ) 111 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering. All Work Upto Plinth Level In 1:3:6 ( 1 Cement : 3 Coarse Sand: 6 Graded Stone Aggregate 20Mm Nominalsize ) . 112 Providing / Laying 50Mm Thick Dpc In 1:2:4 Mix Exculding Cost Of Form Work. 113 Supply Andfillinginplinthwithfine Sandunder Floorsincludingwateringraming, Consolidating And Dressing Complete. 114 P / L Of Cement Concrete Flooring 1:2:4 Finished With A Floating Coat Of Neatcement Slurry And Curing Complete 50Mm Thick 115 Brick Work With Comon Burnt Clay ( Non - Modular ) Bricks Of Classdesignation 7.5 In Foundation In Plinth Including Quarry In Cement Mortar 1:6 Mix 116 Extra For Brick Work In Superstructure Above Plinth Level Upto Floor V Level. 117 Providing / Laying Ofreinforced Cement Concrete 1:2:4 Excluding Cost Of Formworkand Reinforcementmax.Sizeof Graded Stone Agg.20Mm ( Crushed ) Nominal In Lintels, Beams And Suspended Floors. 118 Providing Wood Work In Frames Of Doors, Windows And Cw Wrought Framedand Fixed In Position With Hold Fast Lugs In 1St Class Kail Wood. 119 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors And Windows Fixing With Butt Hinges Of Required Size With Necessary Screw Excluding Panelling, Butt Hinges And Necessary Screws 35Mm Thick 1St Class Kail Wood 120 Extra For Providing Panelling Or Glazing For Panelled / Glazed Shutters. 121 Providing And Fixing Glazed Shutters 35Mm Thick For Doors And Windows. 122 Providing / Fixing Wire Gauze Shutters Using Galvinized M.S Wire Gauze Of Average Width For Aperture 1.4Mm In Both Directions With Wire Dia 0.63Mm In 1St Class Kail Wood. 123 Providing / Fixing Of Flat Iron M.S Hold Fasts. 124 Providing / Fixingm.Sgrillof Requiredpattern Inframes Ofwindows And Cw. 125 Centering Andshutteringincludingstrutting, Proppingetcandremoval Of Same 126 Foundation / Plinth And Septic Tank 127 Wallsseptic Tank 128 Beams, And Lintels, Door Opening, Main Door, Ventilator 129 Suspended Floors, Sofit, Septick Tank, Soakage Pit 130 Edges, Septick Tank, Soakage Pit 131 Steel Reinforcement For Rcc Work Including Straightining, Cutting, Bending, Placing In Position And Binding All Complete 132 20Mm Thick Cement Plaster On Rough Side Of Brick Work In Cement Motar 1:4 133 Pointing On Brick Work Or Brick Flooring With Cement Mortar 1 : 3 ( 1 Cement : 3 Fine Sand ) 134 Providing Andapplying Pop / Wall Putty 2Mm Thick Over Plaster Surface To Prepare The Surface Even And Smooth. 135 Distemperingwithoilbondwashabledistemperofapprovedbrandand Manufacture. 136 Applyingprimingcoatofreadymixedprimerofapprovedbrandand Manufacture On Wood And Wood Based Surface. 137 Painting With Synthetic Enamel Paint Of Approved Brandand Manufacture On Wood And Wood Based Surface. 138 Supplyingandfixing Rolling Shutters Of Approvedmake, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Confirming To Is:4454 Part-1 And M.S. Top Cover Of Required Thickness For Rolling Shutters. 80X1.20 Mm M.S. Laths With 1.20 Mm Thick Top Cover 139 Providing And Fixing Ball Bearing For Rolling Shutters. 140 Providing / Fixing Following Building Hardware Items Inlcuding Screws Etc. Anodized Aluminum Fittings. 141 125Mm Handles 142 200Mm Tower Bolts 143 100Mm Tower Bolts 144 250 X 16Mm Sliding Door Bolts 145 Filling Available Excavated Earth Back Into Trenches And Consolidation. 146 Providing Wood Work In Trusses, Purlins, Rafters Etc. Sawn And Fixed Inposition 1St Class Budloo Or Fir Wood 147 Providing / Fixing 300 X 32Mm 1St Class Kail Wood Eves Boarding 148 Providingcgssheetroofingwithpolynercoatedjorlhooks, Boltsand Nuts8mmdiameterewithbitumenandg.Ilimpetwashersorwithg.I Limpetwashersfilledwithwhiteleadincludingcoatofapprovedsteel Primer And 2 Coats Of Approved Paint On Overlappings Of Sheets Complete. 0.63Mm Thick With Zinc Coating Not Less Than 275 Grams / Sqm. 149 Providingridesorhipesofwidth60cmoverallwidthplaingssheets Including G.I Limpet Washers Filled With White Lead. 150 Providing M. S. Lidwith50x50x 6Mm Angle Ironframe ( 0.75X 1.00M ) Andlidof40x40x6mmframeand30x6mmdiagonalsand1mmm.S Sheet. 151 Providing / Fixing Of Wc Indian Type Orissa Pattern With P Or S Trap And Lowlevel Cistern 580 X 440Mm Size With Foot Rests Complete 152 Providing / Fixing Kitchen Sink 153 Providing / Fixing Bewelled Edge Mirror. 154 Providing / Fixing Floor Traps ( Lmr ) 155 Providing / Fixing Bends With Access Door. 156 100Mm Dia 157 75Mm Dia 158 Providing / Fixing Plain Bends 159 100Mm Dia 160 75Mm Dia 161 Providing / Fixing Double Equal Junctions 100Mm 162 Providing / Fixing Reducer 100 X 75Mm ( Lmr ) 163 Providing / Fixing Vent Pipe 75Mm 164 Providing / Fixing Cowel ( Lmr ) 165 Providing / Fixing Gratting With Jali. 166 Providing / Fixing Pvc Waist Pipe Flexible. 167 Providing / Fixing Holder Bat Clamps 168 100Mm Dia 169 75Mm Dia 170 Providing / Fixing Ball Cock ( Lmr ) 171 Providing / Fixing Pvc Manhole Covers With Frame0.30 X 0.30 172 Providing / Fixing Collars 173 100Mm Dia 174 75Mm Dia 175 Providing / Fixing Of Bib Taps C.P Brass 176 Providing / Filling Joints With Spun Yarn Cement Slurry And Cement Mortar 1:2Mix 177 100Mm Dia 178 75Mm Dia 179 Providing / Fitting Of Gi Pipes With Gi Fittings. 180 Concealed 15Mm Dia 181 In Trenches 20Mm Dia 182 Providing / Fixing Of Pvc Connection Pipe 45Mm Long. 183 Providing / Placing Of Terrace ( At All Floor Levels ) Polyethylene Water Storage Tankisi12701markedwithcoverandsuitablelockingarragementsand Makingnecessaryholesforinletoutletandoverflowpipesbutwithoutfittings And Base Support. 184 Random Rubble Stone Masonry In 1:6 Mix. 185 Random Rubble Stone Masonry In Walls Laid Dry. 186 Providing / Fixing Ceremic Glazed Tiles. 187 Carriageof Materials Bymechanicaltransportinlcludingloading And Unloading Etc Complete. 188 Stone Soling For An Average Lead Of 15Kms. 189 40Mm Stone Aggregate For An Average Lead Of 30Kms. 190 Sand & 20Mm Aggregate For An Average Lead Of 46Kms. 191 Cementfor An Average Lead Of 20Kms. 192 Steel For An Average Lead Of 20Kms. 193 Bricksfor An Average Lead Of 120Kms. 194 Carriageof Materials Uptositeofworkbymanuallabour Inlcludingloading And Unloading Etc Complete For An Average Lead Of 400Mts. 195 Stone Soling 196 40Mm Stone Aggregate. 197 Sand / 20Mm Stone Aggregate 198 Cement 199 Steel 200 Bricks 201 Civil Works ( Pump Station / Platform ) 202 Earth Work In Excavation By Mehanical Means Over Areas Exceeding 30 Cms & Upto 5 M In Depth 1.5M In Width As Well As 10 Sqm. On Plan, Disposal Of Excavated Earth Upto 1 M, Disposed Earth To Be Levelled & Neatly Dressed In All Kinds Of Soils 203 Providing & Laying Of Stone Soling ( Dully Hand Packed ) Including Watering Dressing And Ramming With All Carriages Loading Un-Loading And Stacking Etc Complete 204 Providing & Laying In Position Cement Concrete Of Specified Gradeexcld. The Cost Of Centring And Shuttering All Work Upto Plinth Level ( 1:4:8 Coarse Sand 40 Mm Nominal Size Crushed Stone Agg. ) 205 P / L In Position Specified Grade Of Reinforced Cement Cencrete ( 1:1.5:3 ) Mix Excld. The Cost Of Centring, Shuttering, Finishing And Reinforecement-All Work Upto Plinth Level. With Stone Agg. 20Mmnominal Size 206 Raft 207 Walls 208 P / L Of Reinforced Cement Concrete 1:1.5:3 Mix With 20-Mm Nominal Sizeaggregates Including Curing But Excluding Cost Of Shuttering 209 Slab 210 Beam 211 Column 212 Centering And Shuttering Incld. Strutting, Proping Etc & Removal Of Form Work For Founadtions, Footings, Bases Of Columns For Mass Concrete 213 Raft 214 Walls 215 Cloumn 216 Reinforcement For Rcc Work Incld Straightning, Cutting, Bending, Placing In Position & Binding All Complete ( Thermo-Mechanically Treated Bars ) 217 P / L 12-Mm Thick Cement Plaster In 1:3 With Floating Coat Of Neatcement ( Internal ) 218 Structural Steel Welded In Built Up Sections In Trusses, Frames, Wraught, Purlins Etc. 50X50x6mm 219 Cgi Sheet Roofing 0.63Mm Thick. 220 Providing Constructional Joint By Inserting Pgi Sheet Of 0.63Mmoverall Width Of 0.225M 221 Carriage Of Materails By Mech.Transport, From Source To Site Of Work 222 Sand / 20Mm Stone Agg. For An Avg Lead Of 46 Km 223 Cement For An Avg Lead Of 05 Km 224 Steel For An Avg Lead Of 15 Km 225 Stone Soling For An Avg. Lead Of 30 Km 226 Civil Works ( Sump ) 227 Earth Work In Excavation By Mehanical Means Over Areas Exceeding 30 Cms & Upto 5 M In Depth 1.5M In Width As Well As 10 Sqm. On Plan, Disposal Of Excavated Earth Upto 1 M, Disposed Earth To Be Levelled &Neatly Dressed In All Kinds Of Soils 228 Providing & Laying Of Stone Soling ( Dully Hand Packed ) Including Watering Dressing And Ramming With All Carriages Loading Un-Loading And Stacking Etc Complete 229 Providing & Laying In Position Cement Concrete Of Specified Grade Excld. The Cost Of Centring And Shuttering All Work Upto Plinth Level ( 1:4:8 Coarse Sand 40 Mm Nominal Size Crushed Stone Agg. ) 230 P / L In Position Specified Grade Of Reinforced Cement Cencrete ( 1:1.5:3 ) Mix Excld. The Cost Of Centring, Shuttering, Finishing And Reinforecement-All Work Upto Plinth Level. With Stone Agg. 20Mm Nominal Size 231 Raft 232 Walls 233 Centering And Shuttering Incld. Strutting, Proping Etc & Removal Of Form Work For Founadtions, Footings, Bases Of Columns For Mass Concrete 234 Raft 235 Walls Internal And External 236 Reinforcement For Rcc Work Incld Straightning, Cutting, Bending, Placing In Position & Binding All Complete ( Thermo-Mechanically Treated Bars ) 237 P / L 12-Mm Thick Cement Plaster In 1:3 With Floating Coat Of Neat Cement ( Internal ) 238 P / L 12-Mm Thick Cement Plaster In 1:4 ( External ) 239 Extra For Mixing Of Water Proofing Powder In Cement Concrete Works 240 Providing And Fixing 100-Mm Dia. Flanged Tail Pieces 241 Providing Constructional Joint By Inserting Pgi Sheet Of 0.63Mmoverall Width Of 0.225M 242 Providing And Fixing Of Lid With Angle Iron Frame And Staris To Sr 243 Providing And Fixing Of 100-Mm Dia. Sluice Valves With All Carriage Complete 244 Structural Steel Work Welded In Built Up Sections, Trusses And Framed Work, Incld. Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 245 Carriage Of Materails By Mech.Transport, From Source To Site Of Work 246 Sand / 20Mm Stone Agg. For An Avg Lead Of 15 Km 247 Cement For An Avg Lead Of 15 Km 248 Steel For An Avg Lead Of 15 Km 249 Stone Soling For An Avg. Lead Of 15 Km 250 Carriage Of Materials By Manual Labour, From Source To Site Of Work For An Average Lead Of 400M 251 Sand / Stone Agg.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Sep-2022 Corrigendum-I Date 22-Sep-2022

BOQ

Name of Work: SITC of Electro - Mechanical works for Water Supply Scheme MAZHAMA NEW BEERWAH Stage 1st& 2nd (DISTRICT - BUDGAM)
Sl. No. Item Description
1Stage 1st
2Supply, Installation, Testing & Commissioning of Non-clog Pumping Unit as per IS 5600 at Raw Water Stage. PUMP: - Type of pump :Non–clogOpen wellSubmersible Vertical Pump • Solid Handling Capacity: 20mm (Minimum)/as specified.• Quality of water:Raw water to be handled -Discharge=15000GPH-Head=29Mtrs (Rest Technical Specifications as per Annexure \"F\")
3Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts.
4S/I/T/C of suitable size of GI nipple for pumping equipment at Sr. No.01. The nipple shall be threaded one side as per outlet of pump and weld with suitable size MS flange as per the size of the rising main/ pump delivery.
5Providing and fitting of 16 Sq.mm 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size.Make: L&T/ABB/Havells or equivalent
6Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories (Rest Technical Specifications as per Annexure \"F\")
7Providing, fitting, testing and commissioning of 50KVA voltage stabilizer . (Rest Technical Specifications as per Annexure \"F\")
8Providing and Fitting of 3.5-Core, 50mm2XLPE, 1.1KV and 11KV grade Armoured Aluminum Cable of various sizes conforming toIS:7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. To be fitted from change over panel to modular panel. The job also includes P/F of Aluminumthimbles of various sizes as per size requirement including crimping and tapingMake: L&T/ABB/Havells or equivalent
9Providing/supplying and fitting of 150mm dia G.I flanged Rising Main at site.The Pipe shall be hot dip Galvanized, class C confirming to IS 1239.The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table: 17) Thickness shall conform toIS6392Part1stTable-17.The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints.Make: TATA/prakash/Surya/Jindal or equivalent
10Fabrication / Providing / Fitting of Delivery Manifold with wash out arrangement fabricated out of (Class – C) GI pipe 150 mm and welded with 22 mm thickMS flange as per Table – 17 in two runs of welding . The job also includes cost on account of suitable size nuts, bolts and rubber packing in the flanged joints. The job also includes (12 mtrs) of GI 150 mm pipe arrangements for fitment of pumping equipment in the sump.
11Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) 150mm as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approvedfordrinkingwater).The valve shall be compatibleforburiedapplicationsandshallbesafetoinstall in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve.Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shall be fittedwithRising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job.Make: VAG/Kirloskar/AVK or equivalent
12Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves 150 mm as per IS14846 for regulating the water supply outside the pumping units.The body and bonnent of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valveshallbecompatibleforburiedapplicationsandshallbe safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shallbe fittedwithrising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Make: VAG/Kirloskar/AVK or equivalent
13Fabrication, Providing and fitting of Y- junction having 1m length of each arm to be fabricated out of hot dip galvanized G.I, C-Class pipe. The job also includes Providing and welding of M.S flanges to the ends of each arm. The Thickness of flange shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint by dint of DC arc welding. The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The size of the Y- junction is given below : Dia of the Pipe=150mm
14Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. The ARV Shall have the following specifications: -Valve type - single chamber, single orifice.End connection - flanged ends to IS 1538 Working temperature - 70oc to 550 cTest pressure - body / seat 2.5 x PNSealing ring - EPDMConstruction -ductile iron with stainless steel floats Coating - epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. Make: VAG/Kirloskar/AVK or equivalent
15Fabrication of gantry mechanism by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete Welded The job also includes painting of complete Structure in one coat of red oxide and 02 coats of enamel metal paint.Vertical Posts = ISMC 200No. of vertical posts = 02 Nos.Vertical channel section each post = 02 Nos(seam welded face to face).vertical post bracing = ISMC 100Sole / Matching plates = 500x300x12 thickHeight of vertical posts = 5 Msize of vertical post concrete blocks = 600x600x900 mm(Depth)Concrete grade = M20welding Electrode = Overcord SS of Adore/ESAB/L&T/AdvaniMonorail Section = ISHB 250length of monorail = 5MSteel Detail :i. ISMC 200 5Mx2x2 = 20 M @ 22.3kg/m = 446 kgIi ISMC100 0.25Mx8x2x2 = 8 M@ 9.2kg/m = 73.60 kgiii Plate 0.500x0.300x8 (12mmthk) = 1.20 M²(12thk) = 112.80 kgIv Monorail ISHB250 5 M @ 51.4 kg/M = 257kgsV Bolts/Nuts (L.S) = 30kgs Total = 919.4 Kg say 920 Kg.
16Providing, installation andtestingofmanualtypetriplespurgearchain pulley block having following features:Gears:- The hoist shall have precision machine case Hardened alloy steel gear mountedonbearingsandhousedina dustproofgearbox.Thelubrication of gears should be of high viscosity and temperature for longer life of gears.Load Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation.Load chain wheel:- the load chainwellshouldbedoubleballbearing supportedandSpeciallydesigned,perfectlymachinedwheelproviding correct grip of load chain to makes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below :Make = Pull Lift/Indef or equivalent Capacity = 2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M
17Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. with 2-core 4 mm2 Cu ( 25 m) wiring as per site requirement along withotheraccessorieslikeSS-Combine(02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item.Make = Exide/Luminous or equivalent
18Electrification of Pump House by way of P/F of:-Lighting points in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. Switch, angle / button holder, 9 W LED lamps with necessary fixtures. – 08 jobsLighting points, bulk head type in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. switch, angle / button holder, 9 W LED lampwith necessary fixtures – 06 jobsHeating points in 2.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 16 Amp. SS combine- 04 jobs5-pin socket points in 1.5 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit.- 04 jobs Indicator pointsin 1.0 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit – 04 jobsCeiling Fan with regulator switch, wiring in 1.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. and necessary fixtures. – 02 jobs Distribution Board SP & N ( Regal Grey ) with 01 No incoming and8 way outgoing, fitted with mini MCB “C” series 6A -04 No for lighting points and 2/3 pin socket points and fans, 10 A – 02 No for flood lights, 16 Amp – 02 No for heating points, 63 Amp MCB ( Mains ) – reputed make. The job also includes supply of 05KW sine wave voltage stabilizer single phase 90 – 270 V input for a constant output of 240 V. The fittings shall be modular type of reputed make
19Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mmwide,thickness3mmwith70 Microns Zinc coating having inside arrangement for providing of power connection along with following items.3 Way Terminal Connector 20 Amp.3 No MCB 8 Amp.The job includes fabrication, providing and fitting of three arm GI structure at the top having 120° angle between arms and each arm having 15° inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary.The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” (cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code
20Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36Having following specs:Input: 90-240 V 50 HzPower Factor: >0.9Colour Temperature: 4K - 6.5KBeam Angle: 120° - 170°Lumens: >12000Operating Temperature: -20°C to 60°CThe LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68.The LED is properly fitted on the arm of the pole and connected to the copper wire as provided inthe high mast pole Make = Havells/L&T/Crompton or equivalent
21Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connection to the circuit.
22Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site in charge.
23Providing and carriage of Tool sets comprising of following items as mentioned below, for day today maintenance of Electro-Mechanical equipment’s installedat water supply scheme. The job shall include cost on account of carriage/transportation of tool set to thewater supply scheme. The tools are to be provided in a strong tool box with key and lock mention below of reputed IS makei. Open end Spanner of Size (4/5 to 30/32) (01 complete set)ii. Ring Type Spanner of Size (4/5 to 30/32) (01 complete set)iii. Pliers, 9 inch: (01 No)iv. Nose Pliers 9 inch: (01No)v.Screw Driver 12 inch & 06 Inch:( 01 No Each)vi.Hammer with wooden handle, I Kg (01 No)vii.Pipe Wrench 12 inch: (01 No)viii Electric Multimeter =1No ix. Digital multimeter – 1No. x. Digital Clamp tester capable to measure up to 400A - 1 No. xi. Hack saw frame with hack saw blade – 01 no. Make = Taparia/Jhalani /Everest or equivalent
24Supply, installation of 6 kg CO2 type fire extinguisher manufactured as per IS: 15683 of 2006 with IS mark and comply with DGMS (Approval). The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipment. The cylinder used for fire extinguisher shall be approved by petroleum and explosive safety organization (PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should bemadeof seamless steel (manganese) confirming to IS: 7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS: 15222 of 2002 with certificate.The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO.
25Supply , installation , commissioning and creation of pole mounted, outdoor type Electric Sub Station as per the technical specifications given here under-Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer Type of cooling: ONAN. Operating conditions:Capacity = 63KVA (level-2)Input =11000 voltsOutput =433 volts AC supply in 3- phase. Terminals:Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc.Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge.Transformer Coils:Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved.The HT transformer shallbeofreputed makefroman ISO certifiedcompany as per relevant standards and a test certificate shall be provided before installation. The transformer shall also beprovidedwithbreatherfillwith silica jel crystals, conservator with oil level indicator,explosionvetand adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments.NOTE: The scope of the work shall include obtaining of necessaryinspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate.
26Providing and fitting G.I Channel /Angle/ Flat of sizes including clamps ( for transformer bed, taping point , brackets of poles etc)
27Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs.
28Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation.
29Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class,LA With polymer housing, Station Type.
30Supply and fitting of 11 KV polymeric composite pin / disc insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creep age distance 320mm
31Supply, installation, erection of 9 mtrs long H.T pope of specifications ST-410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per REC standard.
32P/F of Galvanized nuts, bolts of various sizes as per site requirement. (for fitment of electric sub station, poles etc)
33P/F Danger Plate with clamps
34Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices
35Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete.
36Painting of poles Red oxide for 19 Poles
37Painting of poles Aluminum paint for 19 Poles
38Providing, Laying and fitting of ACSR Conductor as per relevant IS standard 0.5 ACSR Conductor
39Providing and fitting of Anchoring clamps comprising clamp body , plastic wedge, steel bill bracket , straps and buckles or nuts and bolts required for holding of 3 – Core , 35 Sq. mm H.T AB Cable.
40P/F of 11 KV cable termination kit for connecting 35Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and HT transformer.
41Providing andfittingofLTDistributionboxforH.TtransformerwithMCCB For incomer and SFU for outgoing circuits.
42P/I of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards.Safe earthing electrode size : 80 mm dia, Length : 2000 mmBack fill compound : 30 kg
43Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase 40kva air cooled Diesel Generator set as per IS 8528 (2018) for engine and IEC/IS 60034-1 for alternator suitably assembled and fitted in a pollution free acoustic enclosure / canopy of required size (Rest Technical Specifications as per Annexure \"F\")
44Earth work inn excavation by manual means in trenches for foundations, drains, pipes, cables etc (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding10 Sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5m, including getting out excavatedearth and disposal of surplus excavated earth asdirected.
45Providing and laying of soling stone
46Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shattering. All works upto plinth level with 1:2:4 mix (1 cement, 2cores sand, 4 graded stone aggregate 20mm nominal size)
47Centering and shattering including strutting, propping etc. and removal of from work for foundation, footings, base for columns
48Providing and fitting of L.T, 3 core , 50mm Sq. capable to work up to 1.1 KV , XLPE insulated , galvanized steel strip armored copper cable conforming to IS : 7098(part -1) 1988 With latest amendments to be fitted from D.G Set to Modular control panel . The job includes providing and fitting of suitable rating copper thimbles duly crimped and taped at conductor ends by hydraulic crimping tool. The job includes earth work in excavation whereverrequired for laying of cable underground. Make: L&T/ABB/Havells or equivalent
49a) Providing of good quality bedding for night stay/Shift consisting of: -i) Mattress with warm cover size 6\"x3\" (6Kg)- 02 No’sii) Quilt with warm cover size 5\"x8\" (6Kg)- 02 No’siii) Pillows with covers - 02 No’siv) Single bed warm blankets with one sided Fur- 02 No’sThe filling material for mattress, quilt and pillow shall be of good quality cottonb) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella (utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. The job also includes providing of thermocool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks,
50Providing of 2 KW heat convector for operators for winter season
51Fabrication of 6’ x 6’ angle iron bed by way of providing and fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded
52Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 no’s including cutting , fixing all complete including painting of the play sheet by one coat of primer and two coats of enamel paint
53Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro- mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate.
54Stage 2nd
55Supply, Installation, Testing & Commissioning of Open Well Pumping Units as per 14220.PUMP: - • Type of pump:Open wellSubmersible Pump (vertical )• Quality of Water to be handled :Filter water/Raw water-Discharge:-20000 GPH-Head:- 30 meter (Rest Technical Specifications as per Annexure \"F\")
56Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts.
57S/I/T/C of suitable size of GI nipple for pumping equipment at Sr. No.01. The nipple shall be threaded one side as per outlet of pump and weld with suitable size MS flange as per the size of the rising main/ pump delivery.
58Providing and fitting of 16 Sq.mm 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size.Make: L&T/ABB/Havells or equivalent
59Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories (Rest Technical Specifications as per Annexure \"F\"
60Providing, fitting, testing and commissioning of 50KVA voltage stabilizer(Rest Technical Specifications as per Annexure \"F\").
61Providing and Fitting of 3.5-Core, 50mm2XLPE, 1.1KV and 11KV grade Armoured Aluminum Cable of various sizes conforming toIS:7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. To be fitted from change over panel to modular panel. The job also includes P/F of Aluminumthimbles of various sizes as per size requirement including crimping and tapingMake: L&T/ABB/Havells or equivalent
62Providing/supplying and fitting of 150mm dia G.I flanged Rising Main at site.The Pipe shall be hot dip Galvanized, class C confirming to IS 1239.The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table: 17) Thickness shall conform toIS6392Part1stTable-17.The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. Make: TATA/prakash/Surya/Jindal or equivalent
63Fabrication / Providing / Fitting of Delivery Manifold with wash out arrangement fabricated out of (Class – C) GI pipe 150 mm and welded with 22 mm thickMS flange as per Table – 17 in two runs of welding . The job also includes cost on account of suitable size nuts, bolts and rubber packing in the flanged joints. The job also includes (12 mtrs) of GI 150 mm pipe arrangements for fitment of pumping equipment in the sump.
64Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) 150mm as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approvedfordrinkingwater).The valve shall be compatibleforburiedapplicationsandshallbesafetoinstall in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve.Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shall be fittedwithRising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job.Make: VAG/Kirloskar/AVK or equivalent
65Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves 150 mm as per IS14846 for regulating the water supply outside the pumping units.The body and bonnent of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valveshallbecompatibleforburiedapplicationsandshallbe safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shallbe fittedwithrising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Make: VAG/Kirloskar/AVK or equivalent
66Fabrication, Providing and fitting of Y- junction having 1m length of each arm to be fabricated out of hot dip galvanized G.I, C-Class pipe. The job also includes Providing and welding of M.S flanges to the ends of each arm. The Thickness of flange shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint by dint of DC arc welding. The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The size of the Y- junction is given below : Dia of the Pipe=150mm
67Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. The ARV Shall have the following specifications: -Valve type - single chamber, single orifice.Nominal dia=50mmEnd connection - flanged ends to IS 1538 Working temperature - 70oc to 550 cTest pressure - body / seat 2.5 x PNSealing ring - EPDMConstruction -ductile iron with stainless steel floats Coating - epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. Make: VAG/Kirloskar/AVK or equivalent
68Fabrication of gantry mechanism by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete Welded The job also includes painting of complete Structure in one coat of red oxide and 02 coats of enamel metal paint.Vertical Posts = ISMC 200No. of vertical posts = 02 Nos.Vertical channel section each post = 02 Nos(seam welded face to face).vertical post bracing = ISMC 100Sole / Matching plates = 500x300x12 thickHeight of vertical posts = 5 Msize of vertical post concrete blocks = 600x600x900 mm(Depth)Concrete grade = M20welding Electrode = Overcord SS of Adore/ESAB/L&T/AdvaniMonorail Section = ISHB 250length of monorail = 5MSteel Detail :i. ISMC 200 5Mx2x2 = 20 M @ 22.3kg/m = 446 kgIi ISMC100 0.25Mx8x2x2 = 8 M@ 9.2kg/m = 73.60 kgiii Plate 0.500x0.300x8 (12mmthk) = 1.20 M²(12thk) = 112.80 kgIv Monorail ISHB250 5 M @ 51.4 kg/M = 257kgsV Bolts/Nuts (L.S) = 30kgs Total = 919.4 Kg say 920 Kg.
69Providing, installation andtestingofmanualtypetriplespurgearchain pulley block having following features:Gears:- The hoist shall have precision machine case Hardened alloy steel gear mountedonbearingsandhousedina dustproofgearbox.Thelubrication of gears should be of high viscosity and temperature for longer life of gears.Load Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation.Load chain wheel:- the load chainwellshouldbedoubleballbearing supportedandSpeciallydesigned,perfectlymachinedwheelproviding correct grip of load chain to makes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below :Make = Pull Lift/Indef or equivalentCapacity = 2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M
70Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. with 2-core 4 mm2 Cu ( 25 m) wiring as per site requirement along withotheraccessorieslikeSS-Combine(02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item.Make = Exide/Luminous or equivalent
71Electrification of Pump House by way of P/F of:-Lighting points in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. Switch, angle / button holder, 9 W LED lamps with necessary fixtures. – 08 jobsLighting points, bulk head type in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. switch, angle / button holder, 9 W LED lampwith necessary fixtures – 06 jobsHeating points in 2.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 16 Amp. SS combine- 04 jobs5-pin socket points in 1.5 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit.- 04 jobs Indicator pointsin 1.0 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit – 04 jobsCeiling Fan with regulator switch, wiring in 1.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. and necessary fixtures. – 02 jobs Distribution Board SP & N ( Regal Grey ) with 01 No incoming and8 way outgoing, fitted with mini MCB “C” series 6A -04 No for lighting points and 2/3 pin socket points and fans, 10 A – 02 No for flood lights, 16 Amp – 02 No for heating points, 63 Amp MCB ( Mains ) – reputed make. The job also includes supply of 05KW sine wave voltage stabilizer single phase 90 – 270 V input for a constant output of 240 V. The fittings shall be modular type of reputed make
72Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mmwide,thickness3mmwith70 Microns Zinc coating having inside arrangement for providing of power connection along with following items.3 Way Terminal Connector 20 Amp.3 No MCB 8 Amp.The job includes fabrication, providing and fitting of three arm GI structure at the top having 120° angle between arms and each arm having 15° inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary.The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” (cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code
73Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36Having following specs:Input: 90-240 V 50 HzPower Factor: >0.9Colour Temperature: 4K - 6.5KBeam Angle: 120° - 170°Lumens: >12000Operating Temperature: -20°C to 60°CThe LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68.The LED is properly fitted on the arm of the pole and connected to the copper wire as provided inthe high mast pole Make = Havells/L&T/Crompton or equivalent
74Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connection to the circuit.
75Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site in charge.
76Providing and carriage of Tool sets comprising of following items as mentioned below, for day today maintenance of Electro-Mechanical equipment’s installedat water supply scheme. The job shall include cost on account of carriage/transportation of tool set to thewater supply scheme. The tools are to be provided in a strong tool box with key and lock mention below of reputed IS makei. Open end Spanner of Size (4/5 to 30/32) (01 complete set)ii. Ring Type Spanner of Size (4/5 to 30/32) (01 complete set)iii. Pliers, 9 inch: (01 No)iv. Nose Pliers 9 inch: (01No)v.Screw Driver 12 inch & 06 Inch:( 01 No Each)vi.Hammer with wooden handle, I Kg (01 No)vii.Pipe Wrench 12 inch: (01 No)viii Electric Multimeter =1No ix. Digital multimeter – 1No. x. Digital Clamp tester capable to measure up to 400A - 1 No. xi. Hack saw frame with hack saw blade – 01 no. Make = Taparia/Jhalani /Everest or equivalent
77Supply, installation of 6 kg CO2 type fire extinguisher manufactured as per IS: 15683 of 2006 with IS mark and comply with DGMS (Approval). The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipment. The cylinder used for fire extinguisher shall be approved by petroleum and explosive safety organization (PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should bemadeof seamless steel (manganese) confirming to IS: 7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS: 15222 of 2002 with certificate.The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO.
78Supply , installation , commissioning and creation of pole mounted, outdoor type Electric Sub Station as per the technical specifications given here under-Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer Type of cooling: ONAN. Operating conditions:Capacity = 100KVA (level-2)Input =11000 voltsOutput =433 volts AC supply in 3- phase. Terminals:Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc.Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge.Transformer Coils:Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved.The HT transformer shallbeofreputed makefroman ISO certifiedcompany as per relevant standards and a test certificate shall be provided before installation. The transformer shall also beprovidedwithbreatherfillwith silica jel crystals, conservator with oil level indicator,explosionvetand adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments.NOTE: The scope of the work shall include obtaining of necessaryinspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate.
79Providing and fitting G.I Channel /Angle/ Flat of sizes including clamps ( for transformer bed, taping point , brackets of poles etc)
80Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs.
81Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation.
82Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class,LA With polymer housing, Station Type.
83Supply and fitting of 11 KV polymeric composite pin / disc insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creep age distance 320mm
84Supply, installation, erection of 9 mtrs long H.T pope of specifications ST-410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per REC standard.
85P/F of Galvanized nuts, bolts of various sizes as per site requirement. (for fitment of electric sub station, poles etc)
86P/F Danger Plate with clamps
87Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices
88Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete.
89Painting of poles Red oxide for 03 Poles
90Painting of poles Aluminum paint for 03 Poles
91Providing, Laying and fitting of ACSR Conductor as per relevant IS standard 0.5 ACSR Conductor
92Providing and fitting of Anchoring clamps comprising clamp body , plastic wedge, steel bill bracket , straps and buckles or nuts and bolts required for holding of 3 – Core , 35 Sq. mm H.T AB Cable.
93P/F of 11 KV cable termination kit for connecting 35Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and HT transformer.
94Providing andfittingofLTDistributionboxforH.TtransformerwithMCCB For incomer and SFU for outgoing circuits.
95P/I of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards.Safe earthing electrode size : 80 mm dia, Length : 2000 mmBack fill compound : 30 kg
96Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase water cooled 50KVADiesel Generator set as per IS 8528 (2018) and ISO:3046(2002) for engine and IEC/IS 60034-1 for alternator suitably assembled and fitted in a pollution free acoustic enclosure / canopy of required size. (Rest Technical Specifications as per Annexure \"F\")
97Earth work inn excavation by manual means in trenches for foundations, drains, pipes, cables etc (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding10 Sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5m, including getting out excavatedearth and disposal of surplus excavated earth asdirected.
98Providing and laying of soling stone
99Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shattering. All works upto plinth level with 1:2:4 mix (1 cement, 2cores sand, 4 graded stone aggregate 20mm nominal size)
100Centering and shattering including strutting, propping etc. and removal of from work for foundation, footings, base for columns
101Providing and fitting of L.T, 3 core , 50mm Sq. capable to work up to 1.1 KV , XLPE insulated , galvanized steel strip armored copper cable conforming to IS : 7098(part -1) 1988 With latest amendments to be fitted from D.G Set to Modular control panel . The job includes providing and fitting of suitable rating copper thimbles duly crimped and taped at conductor ends by hydraulic crimping tool. The job includes earth work in excavation whereverrequired for laying of cable underground.Make: L&T/ABB/Havells or equivalent
102a) Providing of good quality bedding for night stay/Shift consisting of: -i) Mattress with warm cover size 6\"x3\" (6Kg)- 02 No’sii) Quilt with warm cover size 5\"x8\" (6Kg)- 02 No’siii) Pillows with covers - 02 No’siv) Single bed warm blankets with one sided Fur- 02 No’sThe filling material for mattress, quilt and pillow shall be of good quality cottonb) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella (utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. The job also includes providing of thermocool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks,
103Providing of 2 KW heat convector for operators for winter season
104Fabrication of 6’ x 6’ angle iron bed by way of providing and fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded
105Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 no’s including cutting , fixing all complete including painting of the play sheet by one coat of primer and two coats of enamel paint
106Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro- mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications:Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate.
107CIVIL WORKS (OPERATOR QUARTER)
108Earthworkinexcavationbymannualmeansintrenches forfoundation drains,pipes,cables&thelikenotexceeding10sqmonplanincluding disposal of excavated earth up to 50m and lift up to 1.5 m, disposed soil to be neatly dressed
109Providing &Layingof stone soling(dully handpacked)includingwatering dressing and ramming with all carriages loading un-loading and stacking etccomplete
110Providing&layinginpositioncementconcreteofspecifiedgradeexcld.The cost of centring and shuttering all work upto plinth level(1:4:8 coarse sand 40 mm nominal size crushed stone agg.)
111Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level in 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20mm nominalsize).
112Providing/Laying 50mm thick DPC in 1:2:4 mix exculding cost of form work.
113Supply andfillinginplinthwithfine sandunder floorsincludingwateringraming, consolidating and dressing complete.
114P/L of cement concrete flooring 1:2:4 finished with a floating coat of neatcement slurry and curing complete 50mm thick
115Brick work with comon burnt clay (Non - Modular) bricks of classdesignation 7.5 in foundation in plinth including quarry in cement mortar 1:6 mix
116Extra for Brick work in superstructure above plinth level upto floor V level.
117Providing / Laying ofReinforced Cement Concrete 1:2:4 excluding cost of formworkand reinforcementmax.sizeof graded stone agg.20mm(crushed) nominal in Lintels, beams and suspended floors.
118Providing wood work in frames of doors, windows and CW wrought framedand fixed in position with hold fast lugs in 1st class kail wood.
119Providing and fixing panelled or panelled and glazed shutters for doors and windows fixing with butt hinges of required size with necessary screw excluding panelling, butt hinges and necessary screws 35mm thick 1st class kail wood
120Extra for providing panelling or glazing for panelled/ glazed shutters.
121Providing and fixing glazed shutters 35mm thick for doors and windows.
122Providing / fixing wire gauze shutters using galvinized M.S wire gauze of average width for aperture 1.4mm in both directions with wire dia 0.63mm in 1st class kail wood.
123Providing/fixing of flat iron M.S hold fasts.
124Providing/FixingM.Sgrillof requiredpattern inframes ofwindows and CW.
125Centering andshutteringincludingstrutting, proppingetcandremoval of same
126Foundation/Plinth and Septic Tank
127WallsSeptic Tank
128Beams,and lintels, door opening, main door, ventilator
129Suspended Floors, Sofit, septick tank, soakage pit
130Edges, septick tank, soakage pit
131Steel reinforcement for RCC work including straightining, cutting, bending, placing in position and binding all complete
13220mm thick cement plaster on rough side of brick work in cement motar 1:4
133Pointing on brick work or brick flooring with cement mortar 1 : 3(1 cement : 3 fine sand)
134Providing andapplying POP/ wall putty 2mm thick over plaster surface to prepare the surface even and smooth.
135Distemperingwithoilbondwashabledistemperofapprovedbrandand manufacture.
136Applyingprimingcoatofreadymixedprimerofapprovedbrandand manufacture on wood and wood based surface.
137painting with synthetic enamel paint of approved brandand manufacture on wood and wood based surface.
138Supplyingandfixing rolling shutters of approvedmake, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover
139Providing and fixing ball bearing for rolling shutters.
140Providing / Fixing following building hardware items inlcuding screws etc. Anodized Aluminum fittings.
141125mm Handles
142200mm Tower Bolts
143100mm Tower Bolts
144250 x 16mm sliding door bolts
145Filling available excavated earth back into trenches and consolidation.
146Providing wood work in trusses, purlins, rafters etc. sawn and fixed inposition 1st class budloo or fir wood
147Providing/fixing 300 x 32mm 1st class kail wood eves boarding
148ProvidingCGSsheetroofingwithpolynercoatedJorLhooks,boltsand nuts8mmdiameterewithbitumenandG.IlimpetwashersorwithG.I Limpetwashersfilledwithwhiteleadincludingcoatofapprovedsteel primer and 2 coats of approved paint on overlappings of sheets complete. 0.63mm thick with zinc coating not less than 275 grams / Sqm.
149Providingridesorhipesofwidth60cmoverallwidthplainGSsheets including G.I limpet washers filled with white lead.
150Providing M. S. Lidwith50x50x 6mm Angle IronFrame (0.75x 1.00m) andlidof40x40x6mmframeand30x6mmdiagonalsand1mmM.S sheet.
151Providing/fixing of WC Indian type Orissa pattern with P or S trap and lowlevel cistern 580 x 440mm size with foot rests complete
152Providing / fixing Kitchen sink
153Providing / fixing bewelled edge mirror.
154Providing / fixing floor traps (LMR)
155Providing/fixing bends with access door.
156100mm Dia
15775mm Dia
158Providing / fixing Plain bends
159100mm Dia
16075mm Dia
161Providing / fixing double equal junctions 100mm
162Providing / fixing reducer 100 x 75mm (LMR)
163Providing / fixing vent pipe 75mm
164Providing / fixing cowel (LMR)
165Providing / fixing gratting with Jali.
166Providing / fixing PVC Waist Pipe flexible.
167Providing / fixing holder bat clamps
168100mm Dia
16975mm Dia
170Providing/fixing Ball Cock (LMR)
171Providing/fixing PVC manhole covers with frame0.30 x 0.30
172Providing / fixing Collars
173100mm Dia
17475mm Dia
175Providing/fixing of Bib Taps C.P Brass
176Providing/filling joints with spun yarn cement slurry and cement mortar 1:2mix
177100mm Dia
17875mm Dia
179Providing / fitting of GI pipes with GI fittings.
180Concealed 15mm Dia
181In trenches 20mm Dia
182Providing / fixing of PVC connection pipe 45mm long.
183Providing/Placing of terrace (at all floor levels) polyethylene water storage tankISI12701markedwithcoverandsuitablelockingarragementsand makingnecessaryholesforinletoutletandoverflowpipesbutwithoutfittings and base support.
184Random Rubble Stone masonry in 1:6 mix.
185Random Rubble Stone masonry in walls laid dry.
186Providing/fixing ceremic glazed tiles.
187Carriageof materials byMechanicalTransportinlcludingloading and unloading etc complete.
188Stone Soling for an average lead of 15Kms.
18940mm Stone Aggregate for an average lead of 30Kms.
190Sand & 20mm aggregate for an average lead of 46Kms.
191Cementfor an average lead of 20Kms.
192Steel for an average lead of 20Kms.
193Bricksfor an average lead of 120Kms.
194Carriageof materials uptositeofworkbymanuallabour inlcludingloading and unloading etc complete for an average lead of 400mts.
195Stone soling
19640mm Stone Aggregate.
197Sand/ 20mm stone aggregate
198Cement
199Steel
200Bricks
201CIVIL WORKS (PUMP STATION/PLATFORM)
202Earth work in excavation by mehanical means over areas exceeding 30 cms & upto 5 m in depth 1.5m in width as well as 10 sqm. On plan, disposal of excavated earth upto 1 m, disposed earth to be levelled & neatly dressed in all kinds of soils
203Providing & Laying of stone soling (dully hand packed)including watering dressing and ramming with all carriages loading un-loading and stacking etc complete
204Providing & laying in position cement concrete of specified gradeexcld. The cost of centring and shuttering all work upto plinth level(1:4:8 coarse sand 40 mm nominal size crushed stone agg.)
205P/L in position specified grade of reinforced cement cencrete (1:1.5:3) mix excld. the cost of centring, shuttering, finishing and reinforecement-All work upto plinth level. With stone agg. 20mmnominal size
206Raft
207Walls
208P/L of Reinforced cement concrete 1:1.5:3 mix with 20-mm nominal sizeaggregates including curing but excluding cost of shuttering
209Slab
210Beam
211Column
212Centering and shuttering incld. Strutting, proping etc & removal of form work for Founadtions, footings, bases of columns for mass concrete
213Raft
214Walls
215Cloumn
216Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all complete (Thermo-mechanically treated bars)
217P/L 12-mm thick cement plaster in 1:3 with floating coat of neatcement (internal)
218Structural steel welded in built up sections in trusses, frames, wraught,purlins etc. 50x50x6mm
219CGI sheet roofing 0.63mm thick.
220Providing constructional joint by inserting PGI sheet of 0.63mmoverall width of 0.225m
221Carriage of materails By Mech.Transport, from source to site of work
222Sand/20mm Stone Agg. for an avg lead of 46 km
223Cement for an avg lead of 05 km
224Steel for an avg lead of 15 km
225Stone soling for an avg. lead of 30 km
226CIVIL WORKS (SUMP)
227Earth work in excavation by mehanical means over areas exceeding 30 cms & upto 5 m in depth 1.5m in width as well as 10 sqm. On plan, disposal of excavated earth upto 1 m, disposed earth to be levelled &neatly dressed in all kinds of soils
228Providing & Laying of stone soling (dully hand packed)including watering dressing and ramming with all carriages loading un-loading and stacking etc complete
229Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all work upto plinth level(1:4:8 coarse sand 40 mm nominal size crushed stone agg.)
230P/L in position specified grade of reinforced cement cencrete (1:1.5:3) mix excld. the cost of centring, shuttering, finishing and reinforecement-All work upto plinth level. With stone agg. 20mm nominal size
231Raft
232Walls
233Centering and shuttering incld. Strutting, proping etc & removal of form work for Founadtions, footings, bases of columns for mass concrete
234Raft
235Walls internal and external
236Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all complete (Thermo-mechanically treated bars)
237P/L 12-mm thick cement plaster in 1:3 with floating coat of neat cement (internal)
238P/L 12-mm thick cement plaster in 1:4 (External)
239Extra for mixing of water proofing powder in cement concrete works
240Providing and fixing 100-mm dia. Flanged tail pieces
241Providing constructional joint by inserting PGI sheet of 0.63mmoverall width of 0.225m
242Providing and fixing of lid with angle iron frame and staris to SR
243Providing and fixing of 100-mm dia. Sluice valves with all carriage complete
244Structural steel work welded in built up sections, trusses and framed work, incld. cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
245Carriage of materails By Mech.Transport, from source to site of work
246Sand/20mm Stone Agg. for an avg lead of 15 km
247Cement for an avg lead of 15 km
248Steel for an avg lead of 15 km
249Stone soling for an avg. lead of 15 km
250Carriage of materials by manual labour, from source to site of work for an average lead of 400m
251Sand/Stone Agg.

AI Tender Summary

OUR REF NO 33591477
AUTHORITY Government Departments
TENDER VALUE 1.37 Crore
LAST DATE 22-09-2022
Authority
Authority Name Public Health Engineering Department
Work Description Supply Installation Testing And Commissioning Of Electro Mechanical Equipments And Allied Civil Works For Wss Mazhama-2 Supply, Installation, Testing & Commissioning Of Non-Clog Pumping Unit As Per Is 5600 At Raw Water Stage. Pump: - Type Of Pump :Non–Clogopen Wellsubmersible Vertical Pump • Solid Handling Capacity: 20Mm ( Minimum ) / As Specified.• Quality Of Water:Raw Water To Be Handled -Discharge=15000Gph-Head=29Mtrs ( Rest Technical Specifications As Per Annexure F ) 3 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. 4 S / I / T / C Of Suitable Size Of Gi Nipple For Pumping Equipment At Sr. No.01. The Nipple Shall Be Threaded One Side As Per Outlet Of Pump And Weld With Suitable Size Ms Flange As Per The Size Of The Rising Main / Pump Delivery. 5 Providing And Fitting Of 16 Sq.Mm 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size.Make: L&T / Abb / Havells Or Equivalent 6 Fabrication, Providing And Fitting Of Modular Motor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories ( Rest Technical Specifications As Per Annexure F ) 7 Providing, Fitting, Testing And Commissioning Of 50Kva Voltage Stabilizer . ( Rest Technical Specifications As Per Annexure F ) 8 Providing And Fitting Of 3.5-Core, 50Mm2xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming Tois:7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. To Be Fitted From Change Over Panel To Modular Panel. The Job Also Includes P / F Of Aluminumthimbles Of Various Sizes As Per Size Requirement Including Crimping And Tapingmake: L&T / Abb / Havells Or Equivalent 9 Providing / Supplying And Fitting Of 150Mm Dia G.I Flanged Rising Main At Site.The Pipe Shall Be Hot Dip Galvanized, Class C Confirming To Is 1239.The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make. Flanges ( As Per Is 6392 / 1997 Table: 17 ) Thickness Shall Conform Tois6392part1sttable-17.The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint. Welding Electrode Dc Arc Welding Using Welding Electrode Having Diameter Not Less Than 4Mm. Nuts And Bolts Nuts And Bolts ( Conforming To Is:1363 Part 1St ) Rubber Insertion Gaskets Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints.Make: Tata / Prakash / Surya / Jindal Or Equivalent 10 Fabrication / Providing / Fitting Of Delivery Manifold With Wash Out Arrangement Fabricated Out Of ( Class – C ) Gi Pipe 150 Mm And Welded With 22 Mm Thickms Flange As Per Table – 17 In Two Runs Of Welding . The Job Also Includes Cost On Account Of Suitable Size Nuts, Bolts And Rubber Packing In The Flanged Joints. The Job Also Includes ( 12 Mtrs ) Of Gi 150 Mm Pipe Arrangements For Fitment Of Pumping Equipment In The Sump. 11 Providing And Fitting Of Ductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) 150Mm As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approvedfordrinkingwater ) .The Valve Shall Be Compatibleforburiedapplicationsandshallbesafetoinstall In Both Horizontal And Vertical Positions. It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve.Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.Sflangesperfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shall Be Fittedwithrising Main Of The Pumping Unit Atappropriatespotsaspersiterequirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job.Make: Vag / Kirloskar / Avk Or Equivalent 12 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves 150 Mm As Per Is14846 For Regulating The Water Supply Outside The Pumping Units.The Body And Bonnent Of The Valve Shall Be Of Ductile Iron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valveshallbecompatibleforburiedapplicationsandshallbe Safe To Install In Both Horizontal And Vertical Positions It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve. The Valve Shall Be Supplied Along With Hand Wheel. Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.Sflangesperfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shallbe Fittedwithrising Main Of The Pumping Unit Atappropriatespotsaspersiterequirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job. Make: Vag / Kirloskar / Avk Or Equivalent 13 Fabrication, Providing And Fitting Of Y- Junction Having 1M Length Of Each Arm To Be Fabricated Out Of Hot Dip Galvanized G.I, C-Class Pipe. The Job Also Includes Providing And Welding Of M.S Flanges To The Ends Of Each Arm. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint By Dint Of Dc Arc Welding. The Job Further Includes Providing And Fitting Of Nuts And Bolts ( Conforming To Is:1363 Part 1St ) And Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. The Size Of The Y- Junction Is Given Below : Dia Of The Pipe=150Mm 14 Providing, Fitting, Testing And Commissioning Of Arv ( Air Release Valve ) As Per Is 14845 To Be Fitted To G.I Rising Main. The Arv Shall Have The Following Specifications: -Valve Type - Single Chamber, Single Orifice.End Connection - Flanged Ends To Is 1538 Working Temperature - 70Oc To 550 Ctest Pressure - Body / Seat 2.5 X Pnsealing Ring - Epdmconstruction -Ductile Iron With Stainless Steel Floats Coating - Epoxy With Corrosion Resistance Besides The Above Works, The Job Also Cost On Account Of P / F R.I Gasket, Nuts And Bolts Required For Installation Of Arv And Arrangement Of Gas Cutter / Welding Set At Site. Make: Vag / Kirloskar / Avk Or Equivalent 15 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded The Job Also Includes Painting Of Complete Structure In One Coat Of Red Oxide And 02 Coats Of Enamel Metal Paint.Vertical Posts = Ismc 200No. Of Vertical Posts = 02 Nos.Vertical Channel Section Each Post = 02 Nos ( Seam Welded Face To Face ) .Vertical Post Bracing = Ismc 100Sole / Matching Plates = 500X300x12 Thickheight Of Vertical Posts = 5 Msize Of Vertical Post Concrete Blocks = 600X600x900 Mm ( Depth ) Concrete Grade = M20welding Electrode = Overcord Ss Of Adore / Esab / L&T / Advanimonorail Section = Ishb 250Length Of Monorail = 5Msteel Detail :I. Ismc 200 5Mx2x2 = 20 M @ 22.3Kg / M = 446 Kgii Ismc100 0.25Mx8x2x2 = 8 M@ 9.2Kg / M = 73.60 Kgiii Plate 0.500X0.300X8 ( 12Mmthk ) = 1.20 M² ( 12Thk ) = 112.80 Kgiv Monorail Ishb250 5 M @ 51.4 Kg / M = 257Kgsv Bolts / Nuts ( L.S ) = 30Kgs Total = 919.4 Kg Say 920 Kg. 16 Providing, Installation Andtestingofmanualtypetriplespurgearchain Pulley Block Having Following Features:Gears:- The Hoist Shall Have Precision Machine Case Hardened Alloy Steel Gear Mountedonbearingsandhousedina Dustproofgearbox.Thelubrication Of Gears Should Be Of High Viscosity And Temperature For Longer Life Of Gears.Load Chain:- The Load Chain Be Made Of High Tensile Alloy Steel Having Wear Resistance And Greatest Mobility. The Chain Should Be Accurately Collaborated, Tested And Have Adequate In Built Factor Of Safety For Safer Operation.Load Chain Wheel:- The Load Chainwellshouldbedoubleballbearing Supportedandspeciallydesigned, Perfectlymachinedwheelproviding Correct Grip Of Load Chain To Makes The Hoist Most Safe And Reliable Against Any Failure. The Main Specifications Of C.P Block Are Given Below :Make = Pull Lift / Indef Or Equivalent Capacity = 2 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 M 17 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover. With 2-Core 4 Mm2 Cu ( 25 M ) Wiring As Per Site Requirement Along Withotheraccessorieslikess-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item.Make = Exide / Luminous Or Equivalent 18 Electrification Of Pump House By Way Of P / F Of:-Lighting Points In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 9 W Led Lamps With Necessary Fixtures. – 08 Jobslighting Points, Bulk Head Type In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 9 W Led Lampwith Necessary Fixtures – 06 Jobsheating Points In 2.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 16 Amp. Ss Combine- 04 Jobs5-Pin Socket Points In 1.5 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit.- 04 Jobs Indicator Pointsin 1.0 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit – 04 Jobsceiling Fan With Regulator Switch, Wiring In 1.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. And Necessary Fixtures. – 02 Jobs Distribution Board Sp & N ( Regal Grey ) With 01 No Incoming And8 Way Outgoing, Fitted With Mini Mcb “C” Series 6A -04 No For Lighting Points And 2 / 3 Pin Socket Points And Fans, 10 A – 02 No For Flood Lights, 16 Amp – 02 No For Heating Points, 63 Amp Mcb ( Mains ) – Reputed Make. The Job Also Includes Supply Of 05Kw Sine Wave Voltage Stabilizer Single Phase 90 – 270 V Input For A Constant Output Of 240 V. The Fittings Shall Be Modular Type Of Reputed Make 19 Illumination Of Premises: Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mmwide, Thickness3mmwith70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items.3 Way Terminal Connector 20 Amp.3 No Mcb 8 Amp.The Job Includes Fabrication, Providing And Fitting Of Three Arm Gi Structure At The Top Having 120° Angle Between Arms And Each Arm Having 15° Inclination With Respect To Horizontal Plane. Each Arm Should Be Of 2’ Length And Size And Shape Appropriate As Per Requirement Of The Luminary.The Job Also Includes Providing And Fitting Of Required Length Of Flexible Multi Strand 2 Mm Copper Wire From Each Terminal Connector To Each Holding Arm. The Pole Is Mounted On 1:2:4 Cement Concreting Of Size Not Less Than 2’X2’X6” ( Cost Of Concreting Not Included In The Job ) Using 04 No Anchor Bolts Of Required Size Not Less Than 7” In Length. The Complete Job Includes Earthing In Gi Electrode As Per Relevant Is Code 20 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole Vide Item No.36Having Following Specs:Input: 90-240 V 50 Hzpower Factor: >0.9Colour Temperature: 4K - 6.5Kbeam Angle: 120° - 170°Lumens: >12000Operating Temperature: -20°C To 60°Cthe Led Is Pressure Die Cast Aluminum Housing With Power Coated Finish And Having Ingress Protection Up To Ip-68.The Led Is Properly Fitted On The Arm Of The Pole And Connected To The Copper Wire As Provided Inthe High Mast Pole Make = Havells / L&T / Crompton Or Equivalent 21 Providing And Installation Of Junction Box With Dp 32 A Mcb To Serve As Main Switch For Led Lighting. The Job Includes Making Of Electric Connection To The Circuit. 22 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer With Input Voltage 70-240 V And Output 220 V. The Stabilizer Shall Be Installed And Connected To The Electric Circuit As Per Location Provided By Site In Charge. 23 Providing And Carriage Of Tool Sets Comprising Of Following Items As Mentioned Below, For Day Today Maintenance Of Electro-Mechanical Equipment’S Installedat Water Supply Scheme. The Job Shall Include Cost On Account Of Carriage / Transportation Of Tool Set To Thewater Supply Scheme. The Tools Are To Be Provided In A Strong Tool Box With Key And Lock Mention Below Of Reputed Is Makei. Open End Spanner Of Size ( 4 / 5 To 30 / 32 ) ( 01 Complete Set ) Ii. Ring Type Spanner Of Size ( 4 / 5 To 30 / 32 ) ( 01 Complete Set ) Iii. Pliers, 9 Inch: ( 01 No ) Iv. Nose Pliers 9 Inch: ( 01No ) V.Screw Driver 12 Inch & 06 Inch: ( 01 No Each ) Vi.Hammer With Wooden Handle, I Kg ( 01 No ) Vii.Pipe Wrench 12 Inch: ( 01 No ) Viii Electric Multimeter =1No Ix. Digital Multimeter – 1No. X. Digital Clamp Tester Capable To Measure Up To 400A - 1 No. Xi. Hack Saw Frame With Hack Saw Blade – 01 No. Make = Taparia / Jhalani / Everest Or Equivalent 24 Supply, Installation Of 6 Kg Co2 Type Fire Extinguisher Manufactured As Per Is: 15683 Of 2006 With Is Mark And Comply With Dgms ( Approval ) . The Co2 Extinguisher Should Be Suitable For Class B & C Fire And Also For Fire Involving Electrical Equipment. The Cylinder Used For Fire Extinguisher Shall Be Approved By Petroleum And Explosive Safety Organization ( Peso ) As Per Gas Cylinder Rules 2004 And As Per Is: 7285 Of 2004. The Body Should Bemadeof Seamless Steel ( Manganese ) Confirming To Is: 7285 With Is Mark And Should Be Provided With Squeeze Grip Nozzle And Should Be Filled With Co2 Confirming To Is: 15222 Of 2002 With Certificate.The Extinguisher Shall Be Provided With Manufactures Test Certificate And Hydraulic Test Certificate By Bis From Peso. 25 Supply , Installation , Commissioning And Creation Of Pole Mounted, Outdoor Type Electric Sub Station As Per The Technical Specifications Given Here Under-Specifications Conforming To Is: 1180 ( Part 1 ) 2014 With Latest Amendments. Type: Ht / Lt Transformer Type Of Cooling: Onan. Operating Conditions:Capacity = 63Kva ( Level-2 ) Input =11000 Voltsoutput =433 Volts Ac Supply In 3- Phase. Terminals:Input=3 No. Ht Bush Rods With Insulators, Washer, Nuts Etc. Output=4 No. Lt Bush Rods Switch Insulators, Washers, Nuts Etc.Core: The Core Shall Be Of High Permeability To Reduce Core Losses And The Strips Shall Be Of Suitable Size And Gauge.Transformer Coils:Suitable Number Of Ht And Lt Coils In Each Leg Of The Core. The Transformer Coils Shall Be Fabricated Out Of Superior Quality Aluminum Wire / Strips, Properly Wound. The Ht Transformer Is Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage, And All Leads And Lifts Involved.The Ht Transformer Shallbeofreputed Makefroman Iso Certifiedcompany As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Beprovidedwithbreatherfillwith Silica Jel Crystals, Conservator With Oil Level Indicator, Explosionvetand Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is: 1180 ( Part 1 ) 2014 With Latest Amendments.Note: The Scope Of The Work Shall Include Obtaining Of Necessaryinspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate. 26 Providing And Fitting G.I Channel / Angle / Flat Of Sizes Including Clamps ( For Transformer Bed, Taping Point , Brackets Of Poles Etc ) 27 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Of Ht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 28 Supply, Installation, Testing And Commissioning Of 11Kv Polymer Fuses Set Horn Gap 3-Phase 200 A Suitable For Vertical Installation. 29 Supply, Installation, Testing And Commissioning Of Gapless Surge Arrestor Station Class, La With Polymer Housing, Station Type. 30 Supply And Fitting Of 11 Kv Polymeric Composite Pin / Disc Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative , Creep Age Distance 320Mm 31 Supply, Installation, Erection Of 9 Mtrs Long H.T Pope Of Specifications St-410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories .Wherever Required The Job Further Includes G.I Wire Earthing Of Pole As Per Rec Standard. 32 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement. ( For Fitment Of Electric Sub Station, Poles Etc ) 33 P / F Danger Plate With Clamps 34 Providing And Fixing G.I Barbed Wire For Anti-Climbing / Anti-Climbing Devices 35 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp , Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts , 2 N0- Turn Buckle , 1.8 M Long , 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.I Stranded Wire Complete. 36 Painting Of Poles Red Oxide For 19 Poles 37 Painting Of Poles Aluminum Paint For 19 Poles 38 Providing, Laying And Fitting Of Acsr Conductor As Per Relevant Is Standard 0.5 Acsr Conductor 39 Providing And Fitting Of Anchoring Clamps Comprising Clamp Body , Plastic Wedge, Steel Bill Bracket , Straps And Buckles Or Nuts And Bolts Required For Holding Of 3 – Core , 35 Sq. Mm H.T Ab Cable. 40 P / F Of 11 Kv Cable Termination Kit For Connecting 35Sq Mm Xlpe Cable ( Abc Type ) With The Existing Ht Line Near Tapping Point And Ht Transformer. 41 Providing Andfittingofltdistributionboxforh.Ttransformerwithmccb For Incomer And Sfu For Outgoing Circuits. 42 P / I Of Earthing Station For Electric Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size : 80 Mm Dia, Length : 2000 Mmback Fill Compound : 30 Kg 43 Providing, Installation, Testing & Commissioning Of 415 ±10%V ( Output ) , 3 Phase 40Kva Air Cooled Diesel Generator Set As Per Is 8528 ( 2018 ) For Engine And Iec / Is 60034-1 For Alternator Suitably Assembled And Fitted In A Pollution Free Acoustic Enclosure / Canopy Of Required Size ( Rest Technical Specifications As Per Annexure F ) 44 Earth Work Inn Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc ( Not Exceeding 1.5M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5M, Including Getting Out Excavatedearth And Disposal Of Surplus Excavated Earth Asdirected. 45 Providing And Laying Of Soling Stone 46 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centering And Shattering. All Works Upto Plinth Level With 1:2:4 Mix ( 1 Cement, 2Cores Sand, 4 Graded Stone Aggregate 20Mm Nominal Size ) 47 Centering And Shattering Including Strutting, Propping Etc. And Removal Of From Work For Foundation, Footings, Base For Columns 48 Providing And Fitting Of L.T, 3 Core , 50Mm Sq. Capable To Work Up To 1.1 Kv , Xlpe Insulated , Galvanized Steel Strip Armored Copper Cable Conforming To Is : 7098 ( Part -1 ) 1988 With Latest Amendments To Be Fitted From D.G Set To Modular Control Panel . The Job Includes Providing And Fitting Of Suitable Rating Copper Thimbles Duly Crimped And Taped At Conductor Ends By Hydraulic Crimping Tool. The Job Includes Earth Work In Excavation Whereverrequired For Laying Of Cable Underground. Make: L&T / Abb / Havells Or Equivalent 49 A ) Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’Siv ) Single Bed Warm Blankets With One Sided Fur- 02 No’Sthe Filling Material For Mattress, Quilt And Pillow Shall Be Of Good Quality Cottonb ) The Job Also Includes Providing Of Pressure Cooker 5Ltr 02 No’S, Steel Patella ( Utensil ) 5Ltrs 02 No’S, Cooking Heater 01 No., Room Heater 01 No., Steel Buckets 10 Litre Capacity 01 No., Plastic Bucket 10 Litre Capacity With Mug 02 No’S Each, Steel Glasses 06 No’S, Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermocool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Godrej, Link Locks, 50 Providing Of 2 Kw Heat Convector For Operators For Winter Season 51 Fabrication Of 6’ X 6’ Angle Iron Bed By Way Of Providing And Fitting Of Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 52 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 No’S Including Cutting , Fixing All Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 53 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro- Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide. The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 54 Stage 2Nd 55 Supply, Installation, Testing & Commissioning Of Open Well Pumping Units As Per 14220.Pump: - • Type Of Pump:Open Wellsubmersible Pump ( Vertical ) • Quality Of Water To Be Handled :Filter Water / Raw Water-Discharge:-20000 Gph-Head:- 30 Meter ( Rest Technical Specifications As Per Annexure F ) 56 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. 57 S / I / T / C Of Suitable Size Of Gi Nipple For Pumping Equipment At Sr. No.01. The Nipple Shall Be Threaded One Side As Per Outlet Of Pump And Weld With Suitable Size Ms Flange As Per The Size Of The Rising Main / Pump Delivery. 58 Providing And Fitting Of 16 Sq.Mm 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size.Make: L&T / Abb / Havells Or Equivalent 59 Fabrication, Providing And Fitting Of Modular Motor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories ( Rest Technical Specifications As Per Annexure F 60 Providing, Fitting, Testing And Commissioning Of 50Kva Voltage Stabilizer ( Rest Technical Specifications As Per Annexure F ) . 61 Providing And Fitting Of 3.5-Core, 50Mm2xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming Tois:7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. To Be Fitted From Change Over Panel To Modular Panel. The Job Also Includes P / F Of Aluminumthimbles Of Various Sizes As Per Size Requirement Including Crimping And Tapingmake: L&T / Abb / Havells Or Equivalent 62 Providing / Supplying And Fitting Of 150Mm Dia G.I Flanged Rising Main At Site.The Pipe Shall Be Hot Dip Galvanized, Class C Confirming To Is 1239.The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make. Flanges ( As Per Is 6392 / 1997 Table: 17 ) Thickness Shall Conform Tois6392part1sttable-17.The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint. Welding Electrode Dc Arc Welding Using Welding Electrode Having Diameter Not Less Than 4Mm. Nuts And Bolts Nuts And Bolts ( Conforming To Is:1363 Part 1St ) Rubber Insertion Gaskets Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. Make: Tata / Prakash / Surya / Jindal Or Equivalent 63 Fabrication / Providing / Fitting Of Delivery Manifold With Wash Out Arrangement Fabricated Out Of ( Class – C ) Gi Pipe 150 Mm And Welded With 22 Mm Thickms Flange As Per Table – 17 In Two Runs Of Welding . The Job Also Includes Cost On Account Of Suitable Size Nuts, Bolts And Rubber Packing In The Flanged Joints. The Job Also Includes ( 12 Mtrs ) Of Gi 150 Mm Pipe Arrangements For Fitment Of Pumping Equipment In The Sump. 64 Providing And Fitting Of Ductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) 150Mm As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approvedfordrinkingwater ) .The Valve Shall Be Compatibleforburiedapplicationsandshallbesafetoinstall In Both Horizontal And Vertical Positions. It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve.Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.Sflangesperfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shall Be Fittedwithrising Main Of The Pumping Unit Atappropriatespotsaspersiterequirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job.Make: Vag / Kirloskar / Avk Or Equivalent 65 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves 150 Mm As Per Is14846 For Regulating The Water Supply Outside The Pumping Units.The Body And Bonnent Of The Valve Shall Be Of Ductile Iron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valveshallbecompatibleforburiedapplicationsandshallbe Safe To Install In Both Horizontal And Vertical Positions It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve. The Valve Shall Be Supplied Along With Hand Wheel. Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.Sflangesperfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shallbe Fittedwithrising Main Of The Pumping Unit Atappropriatespotsaspersiterequirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job. Make: Vag / Kirloskar / Avk Or Equivalent 66 Fabrication, Providing And Fitting Of Y- Junction Having 1M Length Of Each Arm To Be Fabricated Out Of Hot Dip Galvanized G.I, C-Class Pipe. The Job Also Includes Providing And Welding Of M.S Flanges To The Ends Of Each Arm. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint By Dint Of Dc Arc Welding. The Job Further Includes Providing And Fitting Of Nuts And Bolts ( Conforming To Is:1363 Part 1St ) And Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. The Size Of The Y- Junction Is Given Below : Dia Of The Pipe=150Mm 67 Providing, Fitting, Testing And Commissioning Of Arv ( Air Release Valve ) As Per Is 14845 To Be Fitted To G.I Rising Main. The Arv Shall Have The Following Specifications: -Valve Type - Single Chamber, Single Orifice.Nominal Dia=50Mmend Connection - Flanged Ends To Is 1538 Working Temperature - 70Oc To 550 Ctest Pressure - Body / Seat 2.5 X Pnsealing Ring - Epdmconstruction -Ductile Iron With Stainless Steel Floats Coating - Epoxy With Corrosion Resistance Besides The Above Works, The Job Also Cost On Account Of P / F R.I Gasket, Nuts And Bolts Required For Installation Of Arv And Arrangement Of Gas Cutter / Welding Set At Site. Make: Vag / Kirloskar / Avk Or Equivalent 68 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded The Job Also Includes Painting Of Complete Structure In One Coat Of Red Oxide And 02 Coats Of Enamel Metal Paint.Vertical Posts = Ismc 200No. Of Vertical Posts = 02 Nos.Vertical Channel Section Each Post = 02 Nos ( Seam Welded Face To Face ) .Vertical Post Bracing = Ismc 100Sole / Matching Plates = 500X300x12 Thickheight Of Vertical Posts = 5 Msize Of Vertical Post Concrete Blocks = 600X600x900 Mm ( Depth ) Concrete Grade = M20welding Electrode = Overcord Ss Of Adore / Esab / L&T / Advanimonorail Section = Ishb 250Length Of Monorail = 5Msteel Detail :I. Ismc 200 5Mx2x2 = 20 M @ 22.3Kg / M = 446 Kgii Ismc100 0.25Mx8x2x2 = 8 M@ 9.2Kg / M = 73.60 Kgiii Plate 0.500X0.300X8 ( 12Mmthk ) = 1.20 M² ( 12Thk ) = 112.80 Kgiv Monorail Ishb250 5 M @ 51.4 Kg / M = 257Kgsv Bolts / Nuts ( L.S ) = 30Kgs Total = 919.4 Kg Say 920 Kg. 69 Providing, Installation Andtestingofmanualtypetriplespurgearchain Pulley Block Having Following Features:Gears:- The Hoist Shall Have Precision Machine Case Hardened Alloy Steel Gear Mountedonbearingsandhousedina Dustproofgearbox.Thelubrication Of Gears Should Be Of High Viscosity And Temperature For Longer Life Of Gears.Load Chain:- The Load Chain Be Made Of High Tensile Alloy Steel Having Wear Resistance And Greatest Mobility. The Chain Should Be Accurately Collaborated, Tested And Have Adequate In Built Factor Of Safety For Safer Operation.Load Chain Wheel:- The Load Chainwellshouldbedoubleballbearing Supportedandspeciallydesigned, Perfectlymachinedwheelproviding Correct Grip Of Load Chain To Makes The Hoist Most Safe And Reliable Against Any Failure. The Main Specifications Of C.P Block Are Given Below :Make = Pull Lift / Indef Or Equivalentcapacity = 2 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 M 70 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover. With 2-Core 4 Mm2 Cu ( 25 M ) Wiring As Per Site Requirement Along Withotheraccessorieslikess-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item.Make = Exide / Luminous Or Equivalent 71 Electrification Of Pump House By Way Of P / F Of:-Lighting Points In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 9 W Led Lamps With Necessary Fixtures. – 08 Jobslighting Points, Bulk Head Type In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 9 W Led Lampwith Necessary Fixtures – 06 Jobsheating Points In 2.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 16 Amp. Ss Combine- 04 Jobs5-Pin Socket Points In 1.5 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit.- 04 Jobs Indicator Pointsin 1.0 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit – 04 Jobsceiling Fan With Regulator Switch, Wiring In 1.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. And Necessary Fixtures. – 02 Jobs Distribution Board Sp & N ( Regal Grey ) With 01 No Incoming And8 Way Outgoing, Fitted With Mini Mcb “C” Series 6A -04 No For Lighting Points And 2 / 3 Pin Socket Points And Fans, 10 A – 02 No For Flood Lights, 16 Amp – 02 No For Heating Points, 63 Amp Mcb ( Mains ) – Reputed Make. The Job Also Includes Supply Of 05Kw Sine Wave Voltage Stabilizer Single Phase 90 – 270 V Input For A Constant Output Of 240 V. The Fittings Shall Be Modular Type Of Reputed Make 72 Illumination Of Premises: Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mmwide, Thickness3mmwith70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items.3 Way Terminal Connector 20 Amp.3 No Mcb 8 Amp.The Job Includes Fabrication, Providing And Fitting Of Three Arm Gi Structure At The Top Having 120° Angle Between Arms And Each Arm Having 15° Inclination With Respect To Horizontal Plane. Each Arm Should Be Of 2’ Length And Size And Shape Appropriate As Per Requirement Of The Luminary.The Job Also Includes Providing And Fitting Of Required Length Of Flexible Multi Strand 2 Mm Copper Wire From Each Terminal Connector To Each Holding Arm. The Pole Is Mounted On 1:2:4 Cement Concreting Of Size Not Less Than 2’X2’X6” ( Cost Of Concreting Not Included In The Job ) Using 04 No Anchor Bolts Of Required Size Not Less Than 7” In Length. The Complete Job Includes Earthing In Gi Electrode As Per Relevant Is Code 73 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole Vide Item No.36Having Following Specs:Input: 90-240 V 50 Hzpower Factor: >0.9Colour Temperature: 4K - 6.5Kbeam Angle: 120° - 170°Lumens: >12000Operating Temperature: -20°C To 60°Cthe Led Is Pressure Die Cast Aluminum Housing With Power Coated Finish And Having Ingress Protection Up To Ip-68.The Led Is Properly Fitted On The Arm Of The Pole And Connected To The Copper Wire As Provided Inthe High Mast Pole Make = Havells / L&T / Crompton Or Equivalent 74 Providing And Installation Of Junction Box With Dp 32 A Mcb To Serve As Main Switch For Led Lighting. The Job Includes Making Of Electric Connection To The Circuit. 75 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer With Input Voltage 70-240 V And Output 220 V. The Stabilizer Shall Be Installed And Connected To The Electric Circuit As Per Location Provided By Site In Charge. 76 Providing And Carriage Of Tool Sets Comprising Of Following Items As Mentioned Below, For Day Today Maintenance Of Electro-Mechanical Equipment’S Installedat Water Supply Scheme. The Job Shall Include Cost On Account Of Carriage / Transportation Of Tool Set To Thewater Supply Scheme. The Tools Are To Be Provided In A Strong Tool Box With Key And Lock Mention Below Of Reputed Is Makei. Open End Spanner Of Size ( 4 / 5 To 30 / 32 ) ( 01 Complete Set ) Ii. Ring Type Spanner Of Size ( 4 / 5 To 30 / 32 ) ( 01 Complete Set ) Iii. Pliers, 9 Inch: ( 01 No ) Iv. Nose Pliers 9 Inch: ( 01No ) V.Screw Driver 12 Inch & 06 Inch: ( 01 No Each ) Vi.Hammer With Wooden Handle, I Kg ( 01 No ) Vii.Pipe Wrench 12 Inch: ( 01 No ) Viii Electric Multimeter =1No Ix. Digital Multimeter – 1No. X. Digital Clamp Tester Capable To Measure Up To 400A - 1 No. Xi. Hack Saw Frame With Hack Saw Blade – 01 No. Make = Taparia / Jhalani / Everest Or Equivalent 77 Supply, Installation Of 6 Kg Co2 Type Fire Extinguisher Manufactured As Per Is: 15683 Of 2006 With Is Mark And Comply With Dgms ( Approval ) . The Co2 Extinguisher Should Be Suitable For Class B & C Fire And Also For Fire Involving Electrical Equipment. The Cylinder Used For Fire Extinguisher Shall Be Approved By Petroleum And Explosive Safety Organization ( Peso ) As Per Gas Cylinder Rules 2004 And As Per Is: 7285 Of 2004. The Body Should Bemadeof Seamless Steel ( Manganese ) Confirming To Is: 7285 With Is Mark And Should Be Provided With Squeeze Grip Nozzle And Should Be Filled With Co2 Confirming To Is: 15222 Of 2002 With Certificate.The Extinguisher Shall Be Provided With Manufactures Test Certificate And Hydraulic Test Certificate By Bis From Peso. 78 Supply , Installation , Commissioning And Creation Of Pole Mounted, Outdoor Type Electric Sub Station As Per The Technical Specifications Given Here Under-Specifications Conforming To Is: 1180 ( Part 1 ) 2014 With Latest Amendments. Type: Ht / Lt Transformer Type Of Cooling: Onan. Operating Conditions:Capacity = 100Kva ( Level-2 ) Input =11000 Voltsoutput =433 Volts Ac Supply In 3- Phase. Terminals:Input=3 No. Ht Bush Rods With Insulators, Washer, Nuts Etc. Output=4 No. Lt Bush Rods Switch Insulators, Washers, Nuts Etc.Core: The Core Shall Be Of High Permeability To Reduce Core Losses And The Strips Shall Be Of Suitable Size And Gauge.Transformer Coils:Suitable Number Of Ht And Lt Coils In Each Leg Of The Core. The Transformer Coils Shall Be Fabricated Out Of Superior Quality Aluminum Wire / Strips, Properly Wound. The Ht Transformer Is Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage, And All Leads And Lifts Involved.The Ht Transformer Shallbeofreputed Makefroman Iso Certifiedcompany As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Beprovidedwithbreatherfillwith Silica Jel Crystals, Conservator With Oil Level Indicator, Explosionvetand Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is: 1180 ( Part 1 ) 2014 With Latest Amendments.Note: The Scope Of The Work Shall Include Obtaining Of Necessaryinspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate. 79 Providing And Fitting G.I Channel / Angle / Flat Of Sizes Including Clamps ( For Transformer Bed, Taping Point , Brackets Of Poles Etc ) 80 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Of Ht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 81 Supply, Installation, Testing And Commissioning Of 11Kv Polymer Fuses Set Horn Gap 3-Phase 200 A Suitable For Vertical Installation. 82 Supply, Installation, Testing And Commissioning Of Gapless Surge Arrestor Station Class, La With Polymer Housing, Station Type. 83 Supply And Fitting Of 11 Kv Polymeric Composite Pin / Disc Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative , Creep Age Distance 320Mm 84 Supply, Installation, Erection Of 9 Mtrs Long H.T Pope Of Specifications St-410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories .Wherever Required The Job Further Includes G.I Wire Earthing Of Pole As Per Rec Standard. 85 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement. ( For Fitment Of Electric Sub Station, Poles Etc ) 86 P / F Danger Plate With Clamps 87 Providing And Fixing G.I Barbed Wire For Anti-Climbing / Anti-Climbing Devices 88 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp , Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts , 2 N0- Turn Buckle , 1.8 M Long , 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.I Stranded Wire Complete. 89 Painting Of Poles Red Oxide For 03 Poles 90 Painting Of Poles Aluminum Paint For 03 Poles 91 Providing, Laying And Fitting Of Acsr Conductor As Per Relevant Is Standard 0.5 Acsr Conductor 92 Providing And Fitting Of Anchoring Clamps Comprising Clamp Body , Plastic Wedge, Steel Bill Bracket , Straps And Buckles Or Nuts And Bolts Required For Holding Of 3 – Core , 35 Sq. Mm H.T Ab Cable. 93 P / F Of 11 Kv Cable Termination Kit For Connecting 35Sq Mm Xlpe Cable ( Abc Type ) With The Existing Ht Line Near Tapping Point And Ht Transformer. 94 Providing Andfittingofltdistributionboxforh.Ttransformerwithmccb For Incomer And Sfu For Outgoing Circuits. 95 P / I Of Earthing Station For Electric Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size : 80 Mm Dia, Length : 2000 Mmback Fill Compound : 30 Kg 96 Providing, Installation, Testing & Commissioning Of 415 ±10%V ( Output ) , 3 Phase Water Cooled 50Kvadiesel Generator Set As Per Is 8528 ( 2018 ) And Iso:3046 ( 2002 ) For Engine And Iec / Is 60034-1 For Alternator Suitably Assembled And Fitted In A Pollution Free Acoustic Enclosure / Canopy Of Required Size. ( Rest Technical Specifications As Per Annexure F ) 97 Earth Work Inn Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc ( Not Exceeding 1.5M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5M, Including Getting Out Excavatedearth And Disposal Of Surplus Excavated Earth Asdirected. 98 Providing And Laying Of Soling Stone 99 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centering And Shattering. All Works Upto Plinth Level With 1:2:4 Mix ( 1 Cement, 2Cores Sand, 4 Graded Stone Aggregate 20Mm Nominal Size ) 100 Centering And Shattering Including Strutting, Propping Etc. And Removal Of From Work For Foundation, Footings, Base For Columns 101 Providing And Fitting Of L.T, 3 Core , 50Mm Sq. Capable To Work Up To 1.1 Kv , Xlpe Insulated , Galvanized Steel Strip Armored Copper Cable Conforming To Is : 7098 ( Part -1 ) 1988 With Latest Amendments To Be Fitted From D.G Set To Modular Control Panel . The Job Includes Providing And Fitting Of Suitable Rating Copper Thimbles Duly Crimped And Taped At Conductor Ends By Hydraulic Crimping Tool. The Job Includes Earth Work In Excavation Whereverrequired For Laying Of Cable Underground.Make: L&T / Abb / Havells Or Equivalent 102 A ) Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’Siv ) Single Bed Warm Blankets With One Sided Fur- 02 No’Sthe Filling Material For Mattress, Quilt And Pillow Shall Be Of Good Quality Cottonb ) The Job Also Includes Providing Of Pressure Cooker 5Ltr 02 No’S, Steel Patella ( Utensil ) 5Ltrs 02 No’S, Cooking Heater 01 No., Room Heater 01 No., Steel Buckets 10 Litre Capacity 01 No., Plastic Bucket 10 Litre Capacity With Mug 02 No’S Each, Steel Glasses 06 No’S, Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermocool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Godrej, Link Locks, 103 Providing Of 2 Kw Heat Convector For Operators For Winter Season 104 Fabrication Of 6’ X 6’ Angle Iron Bed By Way Of Providing And Fitting Of Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 105 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 No’S Including Cutting , Fixing All Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 106 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro- Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications:Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide. The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 107 Civil Works ( Operator Quarter ) 108 Earthworkinexcavationbymannualmeansintrenches Forfoundation Drains, Pipes, Cables&Thelikenotexceeding10sqmonplanincluding Disposal Of Excavated Earth Up To 50M And Lift Up To 1.5 M, Disposed Soil To Be Neatly Dressed 109 Providing &Layingof Stone Soling ( Dully Handpacked ) Includingwatering Dressing And Ramming With All Carriages Loading Un-Loading And Stacking Etccomplete 110 Providing&Layinginpositioncementconcreteofspecifiedgradeexcld.The Cost Of Centring And Shuttering All Work Upto Plinth Level ( 1:4:8 Coarse Sand 40 Mm Nominal Size Crushed Stone Agg. ) 111 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering. All Work Upto Plinth Level In 1:3:6 ( 1 Cement : 3 Coarse Sand: 6 Graded Stone Aggregate 20Mm Nominalsize ) . 112 Providing / Laying 50Mm Thick Dpc In 1:2:4 Mix Exculding Cost Of Form Work. 113 Supply Andfillinginplinthwithfine Sandunder Floorsincludingwateringraming, Consolidating And Dressing Complete. 114 P / L Of Cement Concrete Flooring 1:2:4 Finished With A Floating Coat Of Neatcement Slurry And Curing Complete 50Mm Thick 115 Brick Work With Comon Burnt Clay ( Non - Modular ) Bricks Of Classdesignation 7.5 In Foundation In Plinth Including Quarry In Cement Mortar 1:6 Mix 116 Extra For Brick Work In Superstructure Above Plinth Level Upto Floor V Level. 117 Providing / Laying Ofreinforced Cement Concrete 1:2:4 Excluding Cost Of Formworkand Reinforcementmax.Sizeof Graded Stone Agg.20Mm ( Crushed ) Nominal In Lintels, Beams And Suspended Floors. 118 Providing Wood Work In Frames Of Doors, Windows And Cw Wrought Framedand Fixed In Position With Hold Fast Lugs In 1St Class Kail Wood. 119 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors And Windows Fixing With Butt Hinges Of Required Size With Necessary Screw Excluding Panelling, Butt Hinges And Necessary Screws 35Mm Thick 1St Class Kail Wood 120 Extra For Providing Panelling Or Glazing For Panelled / Glazed Shutters. 121 Providing And Fixing Glazed Shutters 35Mm Thick For Doors And Windows. 122 Providing / Fixing Wire Gauze Shutters Using Galvinized M.S Wire Gauze Of Average Width For Aperture 1.4Mm In Both Directions With Wire Dia 0.63Mm In 1St Class Kail Wood. 123 Providing / Fixing Of Flat Iron M.S Hold Fasts. 124 Providing / Fixingm.Sgrillof Requiredpattern Inframes Ofwindows And Cw. 125 Centering Andshutteringincludingstrutting, Proppingetcandremoval Of Same 126 Foundation / Plinth And Septic Tank 127 Wallsseptic Tank 128 Beams, And Lintels, Door Opening, Main Door, Ventilator 129 Suspended Floors, Sofit, Septick Tank, Soakage Pit 130 Edges, Septick Tank, Soakage Pit 131 Steel Reinforcement For Rcc Work Including Straightining, Cutting, Bending, Placing In Position And Binding All Complete 132 20Mm Thick Cement Plaster On Rough Side Of Brick Work In Cement Motar 1:4 133 Pointing On Brick Work Or Brick Flooring With Cement Mortar 1 : 3 ( 1 Cement : 3 Fine Sand ) 134 Providing Andapplying Pop / Wall Putty 2Mm Thick Over Plaster Surface To Prepare The Surface Even And Smooth. 135 Distemperingwithoilbondwashabledistemperofapprovedbrandand Manufacture. 136 Applyingprimingcoatofreadymixedprimerofapprovedbrandand Manufacture On Wood And Wood Based Surface. 137 Painting With Synthetic Enamel Paint Of Approved Brandand Manufacture On Wood And Wood Based Surface. 138 Supplyingandfixing Rolling Shutters Of Approvedmake, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Confirming To Is:4454 Part-1 And M.S. Top Cover Of Required Thickness For Rolling Shutters. 80X1.20 Mm M.S. Laths With 1.20 Mm Thick Top Cover 139 Providing And Fixing Ball Bearing For Rolling Shutters. 140 Providing / Fixing Following Building Hardware Items Inlcuding Screws Etc. Anodized Aluminum Fittings. 141 125Mm Handles 142 200Mm Tower Bolts 143 100Mm Tower Bolts 144 250 X 16Mm Sliding Door Bolts 145 Filling Available Excavated Earth Back Into Trenches And Consolidation. 146 Providing Wood Work In Trusses, Purlins, Rafters Etc. Sawn And Fixed Inposition 1St Class Budloo Or Fir Wood 147 Providing / Fixing 300 X 32Mm 1St Class Kail Wood Eves Boarding 148 Providingcgssheetroofingwithpolynercoatedjorlhooks, Boltsand Nuts8mmdiameterewithbitumenandg.Ilimpetwashersorwithg.I Limpetwashersfilledwithwhiteleadincludingcoatofapprovedsteel Primer And 2 Coats Of Approved Paint On Overlappings Of Sheets Complete. 0.63Mm Thick With Zinc Coating Not Less Than 275 Grams / Sqm. 149 Providingridesorhipesofwidth60cmoverallwidthplaingssheets Including G.I Limpet Washers Filled With White Lead. 150 Providing M. S. Lidwith50x50x 6Mm Angle Ironframe ( 0.75X 1.00M ) Andlidof40x40x6mmframeand30x6mmdiagonalsand1mmm.S Sheet. 151 Providing / Fixing Of Wc Indian Type Orissa Pattern With P Or S Trap And Lowlevel Cistern 580 X 440Mm Size With Foot Rests Complete 152 Providing / Fixing Kitchen Sink 153 Providing / Fixing Bewelled Edge Mirror. 154 Providing / Fixing Floor Traps ( Lmr ) 155 Providing / Fixing Bends With Access Door. 156 100Mm Dia 157 75Mm Dia 158 Providing / Fixing Plain Bends 159 100Mm Dia 160 75Mm Dia 161 Providing / Fixing Double Equal Junctions 100Mm 162 Providing / Fixing Reducer 100 X 75Mm ( Lmr ) 163 Providing / Fixing Vent Pipe 75Mm 164 Providing / Fixing Cowel ( Lmr ) 165 Providing / Fixing Gratting With Jali. 166 Providing / Fixing Pvc Waist Pipe Flexible. 167 Providing / Fixing Holder Bat Clamps 168 100Mm Dia 169 75Mm Dia 170 Providing / Fixing Ball Cock ( Lmr ) 171 Providing / Fixing Pvc Manhole Covers With Frame0.30 X 0.30 172 Providing / Fixing Collars 173 100Mm Dia 174 75Mm Dia 175 Providing / Fixing Of Bib Taps C.P Brass 176 Providing / Filling Joints With Spun Yarn Cement Slurry And Cement Mortar 1:2Mix 177 100Mm Dia 178 75Mm Dia 179 Providing / Fitting Of Gi Pipes With Gi Fittings. 180 Concealed 15Mm Dia 181 In Trenches 20Mm Dia 182 Providing / Fixing Of Pvc Connection Pipe 45Mm Long. 183 Providing / Placing Of Terrace ( At All Floor Levels ) Polyethylene Water Storage Tankisi12701markedwithcoverandsuitablelockingarragementsand Makingnecessaryholesforinletoutletandoverflowpipesbutwithoutfittings And Base Support. 184 Random Rubble Stone Masonry In 1:6 Mix. 185 Random Rubble Stone Masonry In Walls Laid Dry. 186 Providing / Fixing Ceremic Glazed Tiles. 187 Carriageof Materials Bymechanicaltransportinlcludingloading And Unloading Etc Complete. 188 Stone Soling For An Average Lead Of 15Kms. 189 40Mm Stone Aggregate For An Average Lead Of 30Kms. 190 Sand & 20Mm Aggregate For An Average Lead Of 46Kms. 191 Cementfor An Average Lead Of 20Kms. 192 Steel For An Average Lead Of 20Kms. 193 Bricksfor An Average Lead Of 120Kms. 194 Carriageof Materials Uptositeofworkbymanuallabour Inlcludingloading And Unloading Etc Complete For An Average Lead Of 400Mts. 195 Stone Soling 196 40Mm Stone Aggregate. 197 Sand / 20Mm Stone Aggregate 198 Cement 199 Steel 200 Bricks 201 Civil Works ( Pump Station / Platform ) 202 Earth Work In Excavation By Mehanical Means Over Areas Exceeding 30 Cms & Upto 5 M In Depth 1.5M In Width As Well As 10 Sqm. On Plan, Disposal Of Excavated Earth Upto 1 M, Disposed Earth To Be Levelled & Neatly Dressed In All Kinds Of Soils 203 Providing & Laying Of Stone Soling ( Dully Hand Packed ) Including Watering Dressing And Ramming With All Carriages Loading Un-Loading And Stacking Etc Complete 204 Providing & Laying In Position Cement Concrete Of Specified Gradeexcld. The Cost Of Centring And Shuttering All Work Upto Plinth Level ( 1:4:8 Coarse Sand 40 Mm Nominal Size Crushed Stone Agg. ) 205 P / L In Position Specified Grade Of Reinforced Cement Cencrete ( 1:1.5:3 ) Mix Excld. The Cost Of Centring, Shuttering, Finishing And Reinforecement-All Work Upto Plinth Level. With Stone Agg. 20Mmnominal Size 206 Raft 207 Walls 208 P / L Of Reinforced Cement Concrete 1:1.5:3 Mix With 20-Mm Nominal Sizeaggregates Including Curing But Excluding Cost Of Shuttering 209 Slab 210 Beam 211 Column 212 Centering And Shuttering Incld. Strutting, Proping Etc & Removal Of Form Work For Founadtions, Footings, Bases Of Columns For Mass Concrete 213 Raft 214 Walls 215 Cloumn 216 Reinforcement For Rcc Work Incld Straightning, Cutting, Bending, Placing In Position & Binding All Complete ( Thermo-Mechanically Treated Bars ) 217 P / L 12-Mm Thick Cement Plaster In 1:3 With Floating Coat Of Neatcement ( Internal ) 218 Structural Steel Welded In Built Up Sections In Trusses, Frames, Wraught, Purlins Etc. 50X50x6mm 219 Cgi Sheet Roofing 0.63Mm Thick. 220 Providing Constructional Joint By Inserting Pgi Sheet Of 0.63Mmoverall Width Of 0.225M 221 Carriage Of Materails By Mech.Transport, From Source To Site Of Work 222 Sand / 20Mm Stone Agg. For An Avg Lead Of 46 Km 223 Cement For An Avg Lead Of 05 Km 224 Steel For An Avg Lead Of 15 Km 225 Stone Soling For An Avg. Lead Of 30 Km 226 Civil Works ( Sump ) 227 Earth Work In Excavation By Mehanical Means Over Areas Exceeding 30 Cms & Upto 5 M In Depth 1.5M In Width As Well As 10 Sqm. On Plan, Disposal Of Excavated Earth Upto 1 M, Disposed Earth To Be Levelled &Neatly Dressed In All Kinds Of Soils 228 Providing & Laying Of Stone Soling ( Dully Hand Packed ) Including Watering Dressing And Ramming With All Carriages Loading Un-Loading And Stacking Etc Complete 229 Providing & Laying In Position Cement Concrete Of Specified Grade Excld. The Cost Of Centring And Shuttering All Work Upto Plinth Level ( 1:4:8 Coarse Sand 40 Mm Nominal Size Crushed Stone Agg. ) 230 P / L In Position Specified Grade Of Reinforced Cement Cencrete ( 1:1.5:3 ) Mix Excld. The Cost Of Centring, Shuttering, Finishing And Reinforecement-All Work Upto Plinth Level. With Stone Agg. 20Mm Nominal Size 231 Raft 232 Walls 233 Centering And Shuttering Incld. Strutting, Proping Etc & Removal Of Form Work For Founadtions, Footings, Bases Of Columns For Mass Concrete 234 Raft 235 Walls Internal And External 236 Reinforcement For Rcc Work Incld Straightning, Cutting, Bending, Placing In Position & Binding All Complete ( Thermo-Mechanically Treated Bars ) 237 P / L 12-Mm Thick Cement Plaster In 1:3 With Floating Coat Of Neat Cement ( Internal ) 238 P / L 12-Mm Thick Cement Plaster In 1:4 ( External ) 239 Extra For Mixing Of Water Proofing Powder In Cement Concrete Works 240 Providing And Fixing 100-Mm Dia. Flanged Tail Pieces 241 Providing Constructional Joint By Inserting Pgi Sheet Of 0.63Mmoverall Width Of 0.225M 242 Providing And Fixing Of Lid With Angle Iron Frame And Staris To Sr 243 Providing And Fixing Of 100-Mm Dia. Sluice Valves With All Carriage Complete 244 Structural Steel Work Welded In Built Up Sections, Trusses And Framed Work, Incld. Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 245 Carriage Of Materails By Mech.Transport, From Source To Site Of Work 246 Sand / 20Mm Stone Agg. For An Avg Lead Of 15 Km 247 Cement For An Avg Lead Of 15 Km 248 Steel For An Avg Lead Of 15 Km 249 Stone Soling For An Avg. Lead Of 15 Km 250 Carriage Of Materials By Manual Labour, From Source To Site Of Work For An Average Lead Of 400M 251 Sand / Stone Agg.
Basic Detail
Tender No PHE/MRD/TS/ 68 of 08/2022
Bidding Type Tender
Location
City budgam
State Jammu And Kashmir
Key Dates
Publish Date 12 Sep 2022
Submission Date 22 Sep 2022
Open Date 23 Sep 2022
Finance
Tender Value 1.37 Crore
Tender Fee 1000
EMD 2.74 Lakhs
Exemption Not Available
Document List
965e579f-3f2e-4247-ac0b-5e008d3c842a.html
BOQ_467634.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 12, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 22, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 22, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 23, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

965e579f-3f2e-4247-ac0b-5e008d3c842a.html

xls

BOQ_467634.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender