Special Repair / Replacement Of Ber Summer Appliances And Provision Of Three Phase Electric Supply For Phosphating Plant At Bathinda Under Ge ( U ) Bathinda., bathinda-Punjab

Military Engineer Services-MES has published Special Repair / Replacement Of Ber Summer Appliances And Provision Of Three Phase Electric Supply For Phosphating Plant At Bathinda Under Ge ( U ) Bathinda.. Submission Date for this Tender is 19-09-2022. Air Conditioner Tenders in bathinda Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

33577664
Corrigendum : Special Repair / Replacement Of Ber Summer Appliances And Provision Of Three Phase Electric Supply For Phosphating Plant At Bathinda Under Ge ( U ) Bathinda.
Open Tender
Indian
Punjab
bathinda
19-09-2022

Tender Details

Special Repair / Replacement Of Ber Summer Appliances And Provision Of Three Phase Electric Supply For Phosphating Plant At Bathinda Under Ge ( U ) Bathinda.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Aug-2022 CORRIGENDUM NO 1 BOQ 12-09-2022
2 30-Aug-2022 CORRIGENDUM NO 2 BOQ 12-09-2022
3 12-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 52000.0 /-
Tender Value
INR 26 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR / REPLACEMENT OF BER SUMMER APPLIANCES AND PROVISION OF THREE PHASE ELECTRIC SUPPLY FOR PHOSPHATING PLANT AT BATHINDA UNDER GE (U) BATHINDA.
Sl. No. Item Description
1SCHEDULE A PART I Supply, installing , testing and commissioning of split typeAC 1.5 tonne (indoor / out door unit with copper tubes of evaporator and condensor complete) cooling capacity not less than 5000 K Cal/ hour (Minimum) with 5 star BEE rating 2022, inverter technology, cordless remote control unit and with in built air ioniser and plazma filter for batter indoor air quality with stand for outdoor unit, 230 Volt, 50 Hz, single Phasecomplete all as per maunfacturer instructionand direced by Engineer-in-Charge. Note:- Copper pipe, insulation material, PVC clamps , outdoor unit stand and water pipe for condensate as per requirement will be arranged by the contractor and the cost of the same are included in this item and nothing shall be paid extra on this account.
2Supply, installing , testing and commissioning of split typeAC 2 tonne (indoor / out door unit with copper tubes of evaporator and condensor complete) cooling capacity not less than 5000 K Cal/ hour (Minimum) with 5 star BEE rating 2022, inverter technology, cordless remote control unit and with in built air ioniser and plazma filter for batter indoor air quality with stand for outdoor unit, 230 Volt, 50 Hz, single Phasecomplete all as per maunfacturer instructionand direced by Engineer-in-Charge. Note:- Copper pipe, insulation material, PVC clamps , outdoor unit stand and water pipe for condensate as per requirement will be arranged by the contractor and the cost of the same are included in this item and nothing shall be paid extra on this account.
3Supply, installing , testing and commissioning of refrigerator electric driven (Single phase, 230 Volts, 50 Hz) of capacity 310 litres (Minimum) double door, 3 star rating including all built in accessories complete all as directed.
4Supply, installing , testing and commissioning of refrigerator electric driven (Single phase, 230 Volts, 50 Hz) of capacity 165 litres (Minimum) double door, 3 star rating including all built in accessories complete all as directed.
5Supply, installing , testing and commissioning of deep freezerelectric driven (Single phase, 230 Volts, 50 Hz) with hard top single door, storage capacity 300 litres (Minimum)including all built in accessories complete all as directed.
6Supply, installing , testing and commissioning of water cooler fully stainless steel,electric driven (Single phase, 230 Volts, 50 Hz) having approximatestorage capacity 80 litres and normal cooling capacity of 40 litres per hour complete all as directed.
7Supply, installing , testing and commissioning of water cooler fully stainless steel,electric driven (Single phase, 230 Volts, 50 Hz) having approximatestorage capacity 120 litres and normal cooling capacity of 60 litres per hour complete all as directed.
8Supply, installing , testing and commissioning of water cooler fully stainless steel,electric driven (Single phase, 230 Volts, 50 Hz) having approximatestorage capacity 150 litres and normal cooling capacity of 150 litres per hour complete all as directed.
9SCHEDULE A PART II Excavationin trenches not exceeding 1.5 metre wide and not exceeding 1.5 metrein depth for foundation, laying of cables or pipes (where provided)and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed .
10Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / underroads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened,bedded, galvanised steel strip or wire armourd cable(heavy duty) 1100 volt gradewith aluminium conductor having cross sectional area 95 Sqmm3.5 coreconforming to IS-7098 (Part-I -1988) complete allas specified and as directed.
11All as per serial item No 10 above butsectional area 25 Sq mm 4 core.
12M&L for sand cushioning with coarse sand in trenches for protection of underground electric cable, spread to uniform 23 cm thickness and punned down gently to 18 cm complete all as directed.
13Supply and laying un-reinforced precast concrete cable cover, Class LV, Type 1, Flat size 250mm x 150mm x 40mm complete all as specified and directed.
14Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all specified anddirected.
15Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all specified and as directed.
16Supply and laying or fixingGI tubing light grade 80 mm dia for cable protection including fittingunder road / across the drain or nallah / laid in trench complete all as specified and directed by Engineer-in charge .
17Material and labour for making the hole under road and hard standingfor laying and incluidnginserting Galvanised steel light grade pipe up to 150 mm dia including all fittings as required at siteby mechanical drill system or Auger system and making the surface good as per existing surface completed all as specified and directed by Engineer-in-Charge. Note : Galvanised steel light grade pipeshall be paid under respective items.
18Cutting road, demolition of concrete (Un reiforced) in ground floor and paving thickness not exceeding 15 cm (below or above ground level), taking out oldLT under ground cable of any size any description and old pipe, relaying the taking out old serviceable cable and pipe from this job or new cable and pipe in lieu of old unserviceable cable and pipe including material and labour for PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate for making good and matching the existing surface complete all as directed. Note: (a). New GI pipe and UG cable if required shall be measured and paid separately under respective items.
19Supply, fabricating, installation, testing , commissioning and electrically connecting LTpanel Board of size 140cm x 100cm x 60 Cm , 415 volts, factory made dust proof vermin for out door type made out of CRCA sheet 3.15 mm thick except inner sheath of 2 mm, machine pressed both side opening in two halves ,LT Panel internally and externallyshall bepainted with epoxy powder coating paint with 7 tank process for treatment of degreasing, pickling & two coats primer, before being given the stove epoxy finish ,with rubber beading including aluminium bus bar of 250 amp capacity 4 strip mounted on porcelain insulator bus bar chamber shall be provided with inspection covers , each MCCB /cubical switch shall have be indipendent opening panel shall be mounted on angle iron frame and legs made from angle of size 40mm x 40mm x 5mm frame including lifting arrangement and legs duly spray painted internally and externally with two coats of synthetic enamel paint over one coat of red oxide primer , Legsembeading and grouting in PCC (1:2:4) type B1using 20 mm graded crushed stone aggregate in foundationincluding necessay earth work, all connections / control wiring incoming / outgoing with suitable size of PVC insulated copper conductor cable of 1100 / 650 volt gradeincluding Danger Notice stickercomprising of following accessories and testing complete all as directed. (a) MCCB 4 pole200 Amp , 415 volts ,rating with breaking capacity25 KA,adjustable thermal and magnetic setting 50 HzIcs =100% of Icu Ics =100% of Icu - 01 No.(Incomminging) (b) MCCB 4 pole100 Amp , 415 volts ,rating with breaking capacity16 KA,adjustable thermal and magnetic setting 50 HzIcs =100% of Icu Ics =100% of Icu - 03 No.(out going) (c) Digital Volt meter 0-500 Vol with in built selector switch- 01 No(d)Digital Amp meter 0-200 Amp with in built selector switch & CTs of suitable ratio - 01 No(e)Indicator lamp R,Y,B = 01 Setof three (f) Complete panel wiring with tagging and double layer of rubber bidding all as specified.
20Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm burieddirectly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including 32 x 6 mmGI strip upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etcRCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate)including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion and including demolition of old existing one complete all as specified and shown on plate No 3 of SSR Part-I 2009.