| 1 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 2 | Cement Concrete 1:5:10 with stone ballast of size. 40 mm guage. using mechanical mixing |
| 3 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth |
| 4 | Damp proof course 4 cm thick of cement concrete 1: 2: 4 with two coats of bitumen 20/30 penetration @ 1.65 kg per sqm laid hot and sanded. |
| 5 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 6 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 7 | Finishing walls withcement based water soluble exterior paint such as snowcem,robbiacem etc. two or more coats to give an even shade |
| 8 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. |
| 9 | Cement concrete 1:2:4 With stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type |
| 10 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position @35Kg/Sqm For outer boundary towards River Side. |
| 11 | Excavation for Roadway (By Mechanical Means)Excavation in Soil (any type) using Hydraulic Excavator CK 90 Excavation with hydraulic excavator of 0.9 cum bucket capacity including cutting trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lift and combined lead up to 60 mtr. |
| 12 | Compaction of Earth work Compaction of earth work & Preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 300-2 as per Technical clause 305 of MORT&H specifications. (In case of link roads earth work to be done by villagers) |
| 13 | Construction of granular sub-base by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MORD technical specifications |
| 14 | Grassing of grounds with doob grass including uprooting rank vegetation and weeds by digging the area to a depth of 15 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, mixing fertilizer, rough dressing and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts, planting grass roots in rows 10 cm apart in both directions, watering, weeding and maintenance till turf is formed |
| 15 | Planting seasonal flower in beds .Planting seedlings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedlings at 20cm distance from plant to plant and row to row. |
| 16 | Dismantling of brick work in cement sand mortar / lime mortar including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. & staking the serviceable material with all lifts & lead of 100 metre (By Mechanical Means) |
| 17 | Dismantling roofing Jack arch roofing excluding joists or terraced roofing |
| 18 | Dismantling cement conglomerate floors 25mm to 50mm thick without concrete base |
| 19 | Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 20 | Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 21 | Providing and laying vitrified floor tiles (600mm X 600mm)of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ). |
| 22 | Providing and laying vitrified floor tiles of(1000mm X 1000mm) different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. |
| 23 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 24 | Cement (with Dr fixit) rendering on Roof1mm thick |
| 25 | Providing and fixing mineral fibre false ceiling tiles ( NRC 0.55 to 0.6) at all heights of size 595X595x16 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for at hight upto 4 mtr. of size. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. |
| 26 | Burning old paint with blow Lamp |
| 27 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. ThenPainting two or more coatswith synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 28 | 20mm thick cement plaster 1:4 in two coat work |
| 29 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 30 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 31 | Scraping.White wash and colour wash |
| 32 | Interior Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 33 | Providing and fixing helical door spring 150mm (superior quality) including necessary screws, complete, BrassHelical Spring. |
| 34 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm X 16mm |
| 35 | Providing & fixing 100mm with Plate 150mm X 32 mm anodized aluminum Mat Finish handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in charge |
| 36 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 37 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels |
| 38 | Coldtwisteddeformed(Ribbed/TorSteelBar/TMT)BarsFe 500gradeasperIS1786-2008,forR.C.Cworks,wherenot includinginthecompleterateofRCCincludingbendingand placing in position complete |
| 39 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 40 | Structural steel work in girders or Stanchions built up of one joist / or channel section. Riveted including cutting and fixing old gusset plates bolts, Nuts, Rivets etc. complete with flange plates, head, sole plates, angle connections etc. with hoisting & erecting in position. |
| 41 | Applying priming coat with metal primer on new steel or iron work including preparation of surface and Painting two or more coats with aluminum paint to give an even shade. |
| 42 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5- 7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drillingself tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.50 mm (+ 0.05 %) thick. |
| 43 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES-:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface) |
| 44 | Wiring light point |
| 45 | Wiring 6Amp. wall socket point |
| 46 | Wiring 6Amp. Plug control comprising wall socket point |
| 47 | 12.5mm thick cement plaster 1:5 |
| 48 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 49 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. IS Code 15658(2006) |
| 50 | Precast Cement Concrete Kerb, Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications |
| 51 | Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together throughtheir entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed) |
| 52 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/ 10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plateetc, PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface): |
| 53 | Wiring fan point (Without fan box) |
| 54 | Wiring light point |
| 55 | Wiring call-bell point |
| 56 | Wiring 6Amp. wall socket point |
| 57 | Wiring 6Amp. Plug control comprising wall socket point |
| 58 | Wiring 16/20Amp. power plug control point |
| 59 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 60 | Overall size 1.5sq.mm (Un-sheathed) |
| 61 | Overall size 2.5sq.mm (Un-sheathed) |
| 62 | Overall size 4.0sq.mm (Un-sheathed) |
| 63 | Overall size 10sq.mm (Un-sheathed) |
| 64 | Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 65 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 66 | MCB Double Pole 50, 63amp. (10kA, Curve-C) |
| 67 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 68 | Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 69 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered)erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 70 | Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socketshuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 71 | Wiring Computer terminal point having 2 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. Universal Socket (shuttered) and 2Nos. 16/20Amp. switch with indicator (Modular accessories). |
| 72 | Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost ofbove material, cutting and filling up of chases (with finishing the surface):- |
| 73 | Wiring TV socket point (one module) |
| 74 | Wiring Networking socket point RJ45 (one module) |
| 75 | Supply and erection of sheet metal double door Phase segregated distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 3 Nos. shrouded neutral bars, 3 Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label, compartmentalizing each phase (separated incomer, sub incomer & outgoing) and of required no. of ways for mounting FP MCB\"s as incomer, DP/RCBO\"s/RCCB\"s as sub incomer and SP MCB\"s as outgoings in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- |
| 76 | TP&N Double Door Phase Segregated Distribution Board 8 way each |
| 77 | SP&N Double Door Distribution Board 4 way each |
| 78 | Supply and erection of switches, sockets and other accessories (flush pianoype/ modular accessories) in the existing bakelite / modular cover frame including fixing & connections and petty material etc.,:- |
| 79 | Ceiling Rose (Flush Piano type) |
| 80 | Bakelite Batten Holder (Large size) |
| 81 | Supply and erection of Concealed Metal Boxes of various sizes (1/2M, 3M, 4M, 6M, 8M, 12M, 16/18M) with brass lugs recessed in wall for mounting modular accessories including fixing and other petty material etc., including the cost of cutting and filling up of chases (with finishing the surface):- |
| 82 | Powder Coated Concealed Metal Box with Brass Lugs Six Module |
| 83 | Powder Coated Concealed Metal Box with Brass Lugs Eight Module |
| 84 | Powder Coated Concealed Metal Box with Brass Lugs Sixteen/ Eighteen Module (16/18 Module) |
| 85 | Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling). |
| 86 | Earthing with 7/12 S.W.G. (7/2.80mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I.reducing socket 50mm x 20mm (upto 14Metre in length) |
| 87 | Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface)Additional length G.I. wire 7/12 S.W.G. (7/2.80mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 88 | Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 89 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White paintedsuspension rod for ceiling fan. |
| 90 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 91 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 92 | Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed) |
| 93 | Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) |
| 94 | Supply and erection of PVC flexible pipe complete without compression glands,locking arrangement, check-nuts as required:- |
| 95 | PVC Flexible Pipe 25mm dia. |
| 96 | PVC Flexible Pipe 40mm dia. |
| 97 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 98 | Overall size 16sq.mm (4Core) Un-armoured (Loose) |
| 99 | Overall size 35sq.mm (3½ Core) Unarmoured (Loose) |
| 100 | Supply and erection of G.I. Pipe (AClass) Single arm bracket of suitable length to give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the existing surface/ wall with 2nos. MS flat clamp 25mm x 5mm, 30cm long and 4nos. fastner 10mm x 75mm long with two coats of an approved aluminium paint complete in all respect as approved by the Engineerin- charge at site:- |
| 101 | Single Arm Bracket 1 metre Long G.I. Pipe 40mm Dia. |
| 102 | Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm andurrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 103 | Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length) |
| 104 | Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) withpetty material as required etc.:- |
| 105 | Additional Length 25mm x 3mm thick Copper Tape |
| 106 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotaryhandle and relevant PWD generalspecifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 107 | MCCB Four Pole 63/80/100amp., 415volts, =25kA Fixed Magnetic and AdjustableThermal Setting |
| 108 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 109 | Double Walled Corrugated HDPE Pipe 63/ 51mm (Outer/ Inner dia.) |
| 110 | Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) |
| 111 | PVC insulated & PVC sheathed aluminium conductor cable Overall Size 10mm²(1/1.40mm) Twin Core |
| 112 | PVC insulated & PVC sheathed aluminium conductor cable Overall Size 10mm²(1/1.40mm) Twin Core |
| 113 | Supply & erection of pressure die cast aluminium housingstreet light 45wattIP66 make ofPolycab/Panasonic/Havels/Equivalentcomplete in all respects up-to the entire satisfaction of engineer-in-charge |
| 114 | Supply & erection of LEDbatten 36 wattMakeHavels/Polycab/Panasonic/Equivalent complete in all respects up-to the entire satisfaction of engineer-in-charge |
| 115 | Supply & erection ofrecessed slim panel light 15 watt Make Havels/Polycab/Panasonic/Equivalent complete in all respects up-to the entire satisfaction of engineer-in-charge |
| 116 | Supply & Erection of Exhaust Fan 12” (300mm sweep transair ) Single Phase 1400 RPMhaving MS sheet Louverof Make Crompton Havels/PolyCab/Anchor/Equivalent complete in all respects upto to the entire satisfaction of the Engineer-In-Charge |
| 117 | Supply and erection of 4 pairs CAT 6Cable in existing pipes or batten makeHavels/Polycab/Greatwhite/Equivalentin all respect upto the entire satisfaction of the Engineer Incharge |
| 118 | Supply & erection ofwall fency light 15w Make Havels/Samson/Polycab/equivalent complete in all respects up-to the entire satisfaction of engineer-in-charge |
| 119 | Supply & erection ofmirror, wash basin, vanity and bathroom light(3000k)Make Havels/Polycab/Equivalent complete in all respects up-to the entire satisfaction of engineer-in-charge |
| 120 | Supply & Erection of Bulk Head fitting Cat no LBHP 10 CDL WITH 15 Watts lampmakeHavels/Polycab/Equivalent complete in all respects up-to the entire satisfaction of engineer-in-charge |
| 121 | Supply & Erection of Bell Indicator 8way make Cona/Equivalentcomplete in all respects up-to the entire satisfaction of engineer-in-charge |
| 122 | Supply & Erection of LED wall Bed light 10 watt of Make Havels/Samson/Polycab/Equivalent complete in all respects up-to the entire satisfaction of engineer-in-charge |
| 123 | Pannel repair and other petty material , testing and other charges |