The Work Of Installing Poles And Cables Etc. At Dholabhata Area.- 1 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Unarmoured / Armoured Aluminium Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Works In Existing Rcc / H, ajmer-Rajasthan

Department Of Local Bodies has published The Work Of Installing Poles And Cables Etc. At Dholabhata Area.- 1 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Unarmoured / Armoured Aluminium Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Works In Existing Rcc / H. Submission Date for this Tender is 06-09-2022. Cutting Crimping and Punching Tools Tenders in ajmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

33561804
The Work Of Installing Poles And Cables Etc. At Dholabhata Area.- 1 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Unarmoured / Armoured Aluminium Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Works In Existing Rcc / H
Open Tender
Indian
Rajasthan
ajmer
06-09-2022

Tender Details

The Work Of Installing Poles And Cables Etc. At Dholabhata Area.- 1 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Unarmoured / Armoured Aluminium Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Works In Existing Rcc / Hume / Stoneware / Pvc Pipe / Open Duct / Cable Trench With Filling Of Excavated Earth In Trench , On Existing Cable Trays Or On Surface Etc. Including Making Necessary Connection, Testing Etc. As Required Of Size And As Per Points ( A ) , ( B ) , ( C ) , Mentioned Below:- ( A ) Material :- H4- Grade Aluminium Conductor Of Purity >99.6 % & As Per Is:1554 P-I / Is :7098 P – I ( B ) Conductor Shall Have Electrolytic Aluminium Confirming To Is 8130, Is 3975-1999 For Armouring Of Cables In Armoured Cable Items , Is 5831 For Sheath, Is 10810 ( Part 0 To 64 ) For Testing Procedures. ( C ) Oem Must Have Iso 9001 & 14001 Certifications For Qualityassuarance & Its Own In House Nabl Lab Setup For All Testingfacilities For Cables . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All Above As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr. Armoured Cable10.0 Sq.Mm 4 Core 2 Supply & Laying Following Size B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Accessories Like Bend, Socket Etc. For Laying Earth Conductor / Strip / Cable In Ground / Surface / Recess As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr 50 Mm Dia. 3 80 Mm Dai 4 32 Mm Dia Hdpe Pipe Pn 6 ( Class Pe-80 5 Earth Work In Excavation For Roadway, Including Trimming Bottom And Side Slopes In Accordance With Requirement Of Line, Grades And Cross Sections, Including Disposal Of Surplus Material With All Lift And Lead Upto 1000 Metre As Per Mort&H Specification Clause 301. In Ordinary Rock 6 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection With Gi / Cu Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 8 Swg G.I. ( Hot Dipped ) Wire 7 Supply And Erection Of M.S. Galvanized Octagonal Pole ( As Per Bsen 40-3-3:2003 / Bsen 10025 / Is 2062 Is:875 Part-1 – 2015 / For Ms Plate For Base Flange ) Of Following Length And Dimension As Per Table P-01 With Base Plate On The Cement Concrete Foundation Of M- 20 Grade ( 1:1.5:3 ) As Per Is 456 / Is 2911. With The Help Of Anchorbolts Of Grade 6.8 ( Is: 1367 P Iii ) . The Pole Shall Have Aweatherproof Flush Door And Locking Arrangements. Complete In All Respect. All As Per Pre Approved By Engineer In Charge. Foradditional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr .Octagonal Ms Poles Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. ( See Table P -01 For Specs. ) 8 Mtr. 8 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works Withisi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wireshould Be Made From 99.99% Purity Copper, Class 5 Stranding Inacc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm ) Forless Chances Of Oxidization And Higher Silver Content For Gives Betterconductivity , Insulation Pvc Type A Or C , Flame Retardant As Per Is10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , Inexisting Surface Or Recessed Pvc / Ms Conduit / Casing Cappingincluding All As Per Pre Approved By Engineer In Charge, Makingconnections, Etc. As Required. Oem Must Have Its Own In Housenabl Lab Setup For All Testing Facilities For Wires. For Additionaltechnical Parameters Of Products / Work , Refer Annexure AAttached With This Bsr . 2 X 1.5 Sq.Mm 9 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centring And Shuttering - All Work Upto Plinth Level :1:5:10 ( 1 Cement : 5 Fine / Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) 10 Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka ( B / C Tripping Characteristic As Per Type Of Load And Site Requirement ) 4Kv Impulse Withstandvoltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheets, Min. Operation 20, 000 Upto 32 A Rating And 10, 000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Single Pole Mcb6 A To 32 A Rating

Key Value

Document Fees
INR 1000 /-
EMD
INR 92000.0 /-
Tender Value
INR 45.95 Lakhs /-

BOQ Items

Name of Work :/kksykHkkVk {ks= esa iksy o dscy bR;kfn yxkus dk dk;Z
Sl. No. Item Description
1Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. Armoured Cable10.0 Sq.mm 4 core
2Supply & Laying following size" B " class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR 50 mm dia.
380 mm dai
432 mm dia HDPE pipe PN 6 (class PE-80
5Earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of line, grades and cross sections, including disposal of surplus material with all lift and lead upto 1000 metre as per MoRT&H specification clause 301. In ordinary rock
6Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 8 SWG G.I. ( Hot Dipped ) Wire
7Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for base flange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M- 20 grade (1:1.5:3) as per IS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ). The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure "A" attached with this BSR .Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. (See Table P -01 for specs.) 8 Mtr.
8Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works withISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wireshould be made from 99.99% purity copper, class 5 stranding inacc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) forless chances of oxidization and higher silver content for gives betterconductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,makingconnections, etc. as required. OEM Must have its own in houseNABL lab setup for all testing facilities for wires. For additionaltechnical parameters of products/ work , refer Annexure "A"attached with this BSR . 2 x 1.5 sq.mm
9Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level :1:5:10 (1 cement : 5 fine/ coarse sand : 10 graded stone aggregate 40 mm nominal size)
10Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Single pole MCB6 A to 32 A rating
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail