Military Engineer Services-MES has published Repair / Maint Of Window, Split Type Acs And Other Summer / Cooling Appliances At Af Stn Gorkhpur.. Submission Date for this Tender is 09-09-2022. Air Conditioner Tenders in gorakhpur Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 02-Sep-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-09-2022 |
Sl. No. | Item Description |
1 | Servicing of window type AC of capacity 1.5/2.0 ton of any make/ model including removing the AC and cleaning, oiling, servicing and checking for proper functioning and re-fixing at site complete all as specified and directed. Note:- Spare parts will be measured and paid separately |
2 | Servicing of split type AC of capacity 1.5/2.0 ton of any make/ model including removing the AC and cleaning, oiling, servicing and checking for proper functioning and re-fixing at site complete all as specified and directed. Note:- Spare parts will be measured and paid separately |
3 | Checking of window / split AC / water cooler / desert cooler, taking out unserviceable parts like wise relay, compressor, blade, motor,gas leakage, condenser coil, capacitor, thermostat, filter, PCB, wiring etc and all mechanical accessories in day to day and making it serviceable in all respect with replacement of any major part but including minor repairs adhesive cable and other connected accessories by providing sufficient and skilled manpower, work shall also include to check & removal of leakage in window / split AC / water cooler / deep freezer as and when directed complete all as specified and directed. The scope also include complete checking ofwindow/ split/ summer appliances. Note:- (a) The rate quoted by the contractor for Each job is deemed to be included all minor repairs. (b) The contractor or his representative will take complaint from MES complaint register through MES Job card. (c) The contractor will made separate items register with location and signature of user. (d) The contractor will maintain complete detail of JOB card and items involved with date and user signature. (e) The ladder and T&P as required will be provided by the contractor(f)Risk Factor will be on the contractor"s ends. |
4 | Dismantling of window / Split type 1.5 ton Air conditioner and replacing the burnt sealed compressor (Rotary Type) unit by new sealed compressor including all other works such as cleaning and gas charging and re-fixing at sitecomplete all as specified and directed. |
5 | Supply only in replacement condenser coil for 1.5 ton window type A.C. complete all as specified and directed. |
6 | Supply only in replacement relay for 1.5/2.0 ton window / split type A.C. complete all as specified and directed. Make:- Microtech / Renutron |
7 | Supply only in replacement overload protector for 1.5/2.0 ton window / split type A.C. complete all as specified and directed. Make:- Microtech / Renutron |
8 | Supply only in replacement starting capacitor 100-120 MFD, for 1.5/2.0 ton window / split type A.C. complete all as specified and directed. Make:- Teslla or equivalent |
9 | Supply only in replacement running capacitor 36 MFD, for 1.5/2.0 ton window / split type A.C. complete all as specified and directed. Make:- LG / Voltas / Carrier |
10 | Supply only in replacement running capacitor 45 MFD, for 1.5/2.0 ton window / split type A.C. complete all as specified and directed. Make:- LG / Voltas / Carrier |
11 | Supply only in replacement thermostat switch, for 1.5 /2.0 ton window / split type A.C. complete all as specified and directed. |
12 | Supply only in replacement air filter for 1.5/2.0 ton window type A.C. complete all as specified and directed. Make:- LG / Voltas / Carrier |
13 | Supply only in replacement air filter for 1.5/2.0 ton split type A.C. complete all as specified and directed. Make:- LG / Voltas / Carrier |
14 | Taking down electronic circuit board (PCB) of window / split type A.C. 1.5/2.0 ton for repairs and fixing the same after repair complete all as specified and directed. |
15 | S&F in replacement electronic circuit board (PCB) of window / splittype A.C. 1.5/2.0 ton complete all as specified and directed. |
16 | Supply only in replacement wiring kit for 1.5/2.0 ton window type A.C. complete all as specified and directed. |
17 | Supply only in replacement capacitor 4/6 mfd complete all as specified and directed. |
18 | M&L for rewinding of blower motor for 1.5 ton A.C. with superior quality of super enameled copper wire of appropriate sizes in existing weight and gauge including replacement of bush / bearing complete all as specified and directed. |
19 | All as per item No. 18 above but inner unit of split type AC. |
20 | Supply only blower motor for inner unit of 1.5 ton A.C. with superior quality of super enameled copper wire complete all as specified and directed. |
21 | Supply only fan motor for outer unit of 1.5 ton A.C. with superior quality of super enameled copper wire complete all as specified and directed. |
22 | M&L for gas charging in window type A.C. unitof 1.5/2.0 ton capacity using refrigerant gas as per standard practice after flushing, vacuuming including detecting leakage, rectification of leakage, commissioning and testing upto sufficient pressure complete all as specified and directed. |
23 | All as per item No. 22 above but for split type A.C. unitof 1.5/2.0 ton capacity. |
24 | S&F in replacement of sheet metal enclosure with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified. |
25 | S&F in replacement of copper tubing 1/2" heavy duty complete all as specified and directed. |
26 | S&F in replacement of copper tubing 1/4" heavy duty complete all as specified and directed. |
27 | S&F in replacement of copper tubing 5/8" heavy duty complete all as specified and directed. |
28 | S&F in replacement of PVC insulated & sheathed flexible 3 core copper cable of 4 Sqmm complete all as specified and directed. |
29 | S&F in replacement of PVC insulated & sheathed flexible 3 core copper cable of 6 Sqmm complete all as specified and directed. |
30 | Supply only in replacement of new remote control for split / window type AC 1.5 ton/2.0 ton capacity with battery complete all as specified and directed. |
31 | S&F in replacement of new brasmetic hand shut off valve for split type AC complete all as specified and directed. |
32 | Installation / re-installation only split type A.C. electrically driven, 230/250 Volt, AC 50 Hz capacity 1.5/2.0 ton with high wall mounted type fan coil unit (FCU) to be fitted in wall with rowl plug including making holes for inlet / outlet in the wall and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including S&F of unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed. |
33 | S&F in replacement auto swing motor for window/split type AC 1.5/2.0 ton complete all as specified and directed. |
34 | S&F in replacement fan blower set for 1.5 ton split type AC (as per sample) complete all as specified and directed. |
35 | M&L for replacement of unserviceable sealed unit of water cooler with new sealed unit for 200 SF 40/40 litre capacity of water coolers complete all as specified and directed. Make: Kirloskar / Tecumsaw |
36 | All as per item No. 35 above but for 300 SF 80/80 litre capacity of water cooler. |
37 | Supply only in replacement relay assembly for 200 SF 40/40 litre capacity of water cooler complete all as specified and directed. Make: Microtech / Sriram |
38 | All as per item No. 37 above but for 300 SF 80/80 litre capacity of water cooler. |
39 | Supply only in replacement overload protector for 200 SF 40/40 litre capacity of water cooler complete all as specified and directed. Make: Kirloskar / Tecumsaw |
40 | All as per item No. 39 above but for 300 SF 80/80 litre capacity of water cooler. |
41 | Supply only in replacement starting capacitor for 200 SF 40/40 litre capacity of water cooler complete all as specified and directed. Make: Usha / Teslla / Universal / Blue star / Gulmerg |
42 | All as per item No. 41 above but for 300 SF 80/80 litre capacity of water cooler. |
43 | Supply only in replacement running capacitor for 200 SF 40/40 litre capacity of water cooler complete all as specified and directed. Make: Usha / Teslla / Universal / Blue star / Gulmerg |
44 | All as per item No. 43 above but for 300 SF 80/80 litre capacity of water cooler. |
45 | Supply only in replacement thermostat switch for water cooler complete all as specified and directed. Make: Indofoss or equivalent of specified make |
46 | S&F in replacement of chromium plated push cock, self closing, spring loaded type 15 mm dia, with water waste tray for water coolerscomplete all as specified and directed. |
47 | M&L for gas charging in water cooler by using refrigerant gas as per standard practice after proper flushing vacuuming detecting leakage, commissioning and testing complete for 200 SF 40/40 litre capacity of water cooler complete all as specified and directed. |
48 | All as per item No. 47 above but for 300 SF 80/80 litre capacity of water cooler. |
49 | M&L for repair to refrigerator 165 to 190 litre capacity complete by cleaning of system properly with CTC, charging refrigerant gas including replacement of unserviceable sealed unit (Compressor) of refrigerator with new sealed unit, complete all as specified and directed. Make: Kirloskar / Tecumsaw |
50 | All as per item No. 49 above but for 210 to 315 litre capacity of refrigerator. |
51 | S&F in replacement of box type relay for any make and capacity of refrigerator complete all as specified and directed. Make: Microtech / Renutrol |
52 | S&F in replacement condensing coil for 165 to 190 litre capacity of refrigerator complete all as specified and directed. |
53 | All as per item No. 52 above but for 210 to 315 litre capacity of refrigerator. |
54 | Supply only in replacement condensing coil for 200 SF 40/40 litre capacity of water cooler complete all as specified and directed. Make: Usha / Teslla / Universal / Blue star / Gulmerg |
55 | All as per item No. 54 above but for 300 SF 80/80 litre capacity of water cooler. |
56 | M&L for gas charging by using refrigerant gas as per standard practice after proper flushing vacuuming detecting leakage, commissioning and testing complete for 165 to 190 litre capacity of refrigerator complete all as specified and directed. |
57 | All as per item No. 56 above but for 210 to 315 litre capacity of refrigerator. |
58 | All as per item No. 56 above but for 180 to 310 litre capacity of Deep fridge. |
59 | S&F in replacement vertical water lifting pump, single phase, 1/7 HP or any HP suitable for desert coolers complete all as specified and directed. Make: Summerking / Summer cool / MEI / Crompton |
60 | S&F in replacement fan motor, single phase, 1/7 HP or any HP suitable for desert coolers complete all as specified and directed. Make: Summerking / Summer cool / MEI / Crompton |
61 | S&F in replacement wood wool pad for desert cooler of suitable size with connected access complete all as specified and directed. (one set of 3 nos) |
62 | M&L for rewinding of 5 KVA main transformer of voltage stabilizer using superior quality of super enameled copper wire of core matching size complete with varnishing dying and refixed in stabilizer complete all as specified and directed. |
63 | All as per item No. 62 above but for 4 KVA. |
64 | S&F in replacement of PCB matching size of voltage stabilizer 5/4 KVA of single phase operation in AC supply complete all as specified and directed. |
65 | S&F in replacement of TDR for voltage stabilizer 4/5 KVA complete all as specified and directed. |
66 | S&F in replacement of voltmeter 0-300 volt for voltage stabilizer 4/5 KVA complete all as specified and directed. |
67 | S&F in replacement of MCB SP 20A for voltage stabilizer 4/5 KVA complete all as specified and directed. |
68 | S&F in replacement of thermostat for any make and capacity of refrigerator complete all as specified and directed. Make: Microtech/Renutrol |
69 | S&Fin replacement of switch Assembly 5A as per sample complete all as specified and directed. |
70 | S&Fin replacement of plug top 5A/15A as per sample complete all as specified and directed. |
71 | S&F in replacement of push cock CP 15 mm dia for water cooler complete all as specified and directed. |