Repairs / Maint Of Lt Panels, Starters, Mcc Panels, Water Meters, Apfc Panels, Pump Sets, Motors, Dg Set, Solar Water Heaters, Solar Pannel Plates And Connected Works At Various Mes Installation At Subathu Under Ge Kasauli, subathu-Himachal Pradesh

Military Engineer Services-MES has published Repairs / Maint Of Lt Panels, Starters, Mcc Panels, Water Meters, Apfc Panels, Pump Sets, Motors, Dg Set, Solar Water Heaters, Solar Pannel Plates And Connected Works At Various Mes Installation At Subathu Under Ge Kasauli. Submission Date for this Tender is 05-09-2022. Starter Tenders in subathu Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33552081
Corrigendum : Repairs / Maint Of Lt Panels, Starters, Mcc Panels, Water Meters, Apfc Panels, Pump Sets, Motors, Dg Set, Solar Water Heaters, Solar Pannel Plates And Connected Works At Various Mes Installation At Subathu Under Ge Kasauli
Open Tender
Indian
Himachal Pradesh
subathu
05-09-2022

Tender Details

Repairs / Maint Of Lt Panels, Starters, Mcc Panels, Water Meters, Apfc Panels, Pump Sets, Motors, Dg Set, Solar Water Heaters, Solar Pannel Plates And Connected Works At Various Mes Installation At Subathu Under Ge Kasauli

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: REPAIRS/ MAINT OF LT PANELS, STARTERS, MCC PANELS, WATER METERS, APFC PANELS, PUMP SETS, MOTORS, DG SET, SOLAR WATER HEATERS, SOLAR PANNEL PLATES AND CONNECTED WORKS AT VARIOUS MES INSTALLATION AT SUBATHU UNDER GE KASAULI.
Sl. No. Item Description
1Schedule "A" Section - I
2M&L for opening up existing LT MCC panel of any capacity pump set from 05 HP to 240 HP pump set duly disconnecting all electrical connection and checking throughly all connection wiring from contactor to starter and all other relays etc and removing all defective parts and replace with new parts and replacing defective connection wire of any size and making the MCC panel in 100% serviceable condition. After sucessfully repair of MCC panel testing will be carried out upto the satisfaction of Engr-in-Charge.( Note .Spares required will be measured and paid separately under respective items. (ii) Cost of copper wire reqquired to be replace is deemed to be included in the quoted rate.(iii) The work will be carried out through authorised person only of the original manufacturer of existing make of Panel/Accessories)
3Supply & fixing in repairs Volt Meter Digital, 96 x 96 mm,0-500 Volts,Class 1, AC.
4Supply & fixing in repairs Amp Meter Digital, 96 x 96 mm,0-100 Amps,Class 1, AC.
5Supply & fixing in repairs die cast resin CT, Class 1, for digital Amp Meters. Ratio of CT- all as directed by Engineer- in-Charge.
6Taking out old & unserviceable power contactor and Supply & fix power contactor for S/D starter for 220/240 HP3 pole, 400 Amps for AC 3 rating 415 volts, 50 Hz supply including control coil, 6 fixed & 3 moving contacts, contact springs, spring retainers and arc runners complete with 2No+2NC .
7Taking out old & unserviceable power contactor and Supply & fix power contactor for S/D starter for 220/240 HP 3 pole, 265 Amps for AC 3 rating 415 volts, 50 Hz supply including control coil, 6 fixed & 3 moving contacts, contact springs, spring retainers and arc runners complete with 1 No+1NC.
8Taking out old & unserviceable power contactor and Supply & fix power contactor for S/D starter for 180 HP3 pole, 150 Amps for AC 3 rating 415 volts, 75 kW 50 Hz supply including control coil, 6 fixed & 3 moving contacts, contact springs, spring retainers and arc runners complete with 1 No+1NC.
9Taking out old & unserviceable power contactor and Supply & fixing Citation series 3 pole contactor for S/D starter for AC1 rating 300 Amps, 140 Amps for AC 3 rating 415 volts, 75 kW 50 Hz supply including control coil, 6 fixed & 3 moving contacts, contact springs, spring retainers and arc runners complete with 1 No+1NC.
10Taking out old & unserviceable power contactor and Supply & fix power contactor for S/D starter for 100/ 125 HP3 pole, 95 Amps for AC 3 rating 415 volts, 50 Hz supply including control coil, 6 fixed & 3 moving contacts, contact springs, spring retainers and arc runners complete with 1 No+1NC.
11Taking out old & unserviceable power contactor and Supply & fix power contactor for S/D starter 3 pole, 70 Amps for AC 3 rating 415 volts, 50 Hz supply,37 kw including control coil, 6 fixed & 3 moving contacts, contact springs, spring retainers and arc runners complete with 2 No+2NC Auxillary coil ( PAO P/H)
12Taking out old & unserviceable power contactor and Supply & fix power contactor for S/D starter 3 pole, 40 Amps for AC 3 rating 415 volts, 50 Hz supply,22 kw including control coil, 6 fixed & 3 moving contacts, contact springs, spring retainers and arc runners complete with 2 No+2NC Auxillary coil ( Gamber old raw water P/H)
13Taking out old & unserviceable power contactor and Supply & fix power contactor for S/D starter 3 pole, 32 Amps for AC 3 rating 415 volts, 22 kW 50 Hz supply including control coil, 1NO+1NC, contact springs, spring retainers and arc runners complete.
14Taking out old & unserviceable power contactor and Supply & fix power contactor for S/D starter 20 HP3 pole, 25 Amps for AC 3 rating 415 volts,11 kW 50 Hz supply including control coil, 1NO+1NC, contact springs, spring retainers and arc runners complete.
15Taking out old & unserviceable contactor and Supply & fixcontactor for S/D starter 7.5 HP ,3 pole,12 Amps for AC 3 rating 415 volts, 5.5 KW , 50 Hz supply including control coil, 1NO+1NC, contact springs, spring retainers and arc runners complete.
16Taking out old & unserviceable Spare Kitand Supply & fix Spare Contacts set for Freedom Contactors 400 A Contactor including control coil, 6 fixed & 3 moving contacts, contact springs, spring retainers and arc runners complete.
17Taking out old & unserviceable Spare Kitand Supply & fix Spare Contact Kit set for 265 A Contactor including control coil,6 Fixed contacts 3 Moving contacts ,12 CSK screws & washers 3 Springs Spring retainers Self tapping screws & washers 6 Arc Chute assly & screws complete.
18Taking out old & unserviceable Spare Kitand Supply & fix Spare Contact Kit set for 140 A Contactor including control coil, 6 fixed & 3 moving contacts, contact springs, spring retainers and arc runners complete.
19Taking out old & unserviceable Pneumatic Timer and Supply & fix Pneumatic Timers ,with time delay Relay-Electro Pneumatic timer of 0.05 sec to 60 sec time range complete with 1No +1NC.
20Taking out old & unserviceable Pneumatic Timer and Supply & fix Pneumatic Timers ,with time delay Relay-Electro Pneumatic timer of 0.05 sec to 60 sec time range complete with 1No +1NC.
21S&F electronic star delta Encapsulated on delay Timer Type SAS-P (Solid State output) SST00 0 1125, Voltages : 240V AC, 110V AC, 48V AC/DC, 24V AC/DC, Time Range : 1 sec. or 0.1-10 Sec. or 1-100 Sec.DQR 415/240V,110V : AC complete.
22Supply & fixing in repairsMicroprocessor based Electronic Over current Relay for protection against Motor Over current, Under current, Phase Loss, Phase Reverse, Locked Rotor, Phase Unbalance, inbuilt display type (415 volts) including 1 No CT Cl-1.0 15VA Resin Cast,
23Supply & fixing in repairsMagnetic Coilfor BCH 54contactor (400 Amp contactor) .
24Supply & fixing in repairsMagnetic Coil for BCH 15NTcontactor(150 Amp contactor)
25Supply & fixing in repairsMagnetic Coil for MCE 15L, MCE 15MO, MCE15M( 80/95 Ampscontactor) contactor.
26Supply & fixing in repairsMagnetic Coil for C4NE22contactor( 40 Amp Contactor).
27Supply & fixing in repairsControl Relay Freedom Series (2 NO + 2 NC) for AC Supply.
28Supply & fixing in repairs Auxillary front mounting contact block with 2 NO + 2 NC.
29Supply & fixing in repairsAuxillary side mounting contact block with 1 NO + 1 NC.
30S&F Push Button 22.5 mm with push knob flush type having 1 NO & 1 NCilluminated type for putting on / off the starter.
31S&F LED indicating light surge and low voltage protected 220 / 240 Volts AC, Colour R/Y/G/A for LT Panels.
32S&F MCCB 3 pole, 415 volts, AC 50 Hz, breaking capacity-36 KA, of rating 400 Amps.
33S&F MCCB 3 pole, 415 volts, AC 50 Hz, breaking capacity-36 KA, of rating 250 Amps.
34S&F MCCB 4 pole, 415 volts, AC 50 Hz, breaking capacity-36 KA, of rating 250 Amps.
35S&F MCCB 3 pole, 415 volts, AC 50 Hz, breaking capacity- 36 KA, of rating 160 Amps.
36S&F MCCB 3 Pole, 415 volts, AC 50 Hz, breaking capacity-18 KA, of rating 63 Amps.
37Supply / laid PVC insulated unsheathed multistrandedHRFR 3 x single coe ( R,Y,B) copper conductor 1100 volts gradeof size 16 sqmm passing through existing PVC/ERW conduit from starter upto pump fixed with required size of copper lugs complete all as specified and directed by Engr-in-Charge.( Note- 3 single core wire of 16 sqmm ( colour coding RYB) will be measured as one length of 1 RM).
38Dismantling complete solar water heating system ofcapacity 1000 LPDincluding hot & cold water pipes and hot water tank complete. Checking thoroughly for repair ,taking out the solar energy collector panel of solar water heating system row carefully and setting aside for re-use after repairs.Removing the glass covers carefully and setting aside at safe place for re-use and carry out following repair works- (a) Dismantling the solar panel descaling of hot water pipes by using appropriate chemicals, cleaning and washing all copper tube throughly cleaning the complete panel, making the tubes scale free, and re-assembling the panel. (b) Brazing the leaking broken copper tubes & fins with copper alloy brazing rod to make the panel water tight (c) Cleaning hot and cold water tanks. (d) replacement of worn out missing nuts bolts, washers, union sockets, flanges and screws etc .After sucessfully repair of the complete system re-fixing back in existing position and testing complete all as specified and directed. (Note:-All other materials shall be measured and paid separately under respective items).
39All as item No 37.00 above but capacity 500 ltrs.
40All as item No 37.00 above but capacity 200 ltrs.
41Supply and fixing in repairs Solar collector flat plate,cu-cu ,absorber area 2 sq.mtr,glazing-4mm with toughened glass solar energy collector panel complete of capacity 100 ltrs per daycomplete all as specified anddirected by Eng- in -charge.
42Supply and fixing in repairs solar energy collector panelglass (Collector toughened Glass) complete of capacity 100 ltrs per daycomplete all as specified anddirected by Eng- in -charge.
43Supply and fixingIn repairssolar panel gasket made out of fine rubber to make system air tight, dust, and water proof complete all as specified anddirected by Eng- in -charge.
44S & F In repairs Heavy duty Heating Element with thermostat of 3kw capacity complete of suitable size incl fixing accessories complete all as specified anddirected by Eng- in -charge.
45Supply, laying, testing and commissioning of cable LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core incl confirming to IS specification including taking out existing unserviceable cable complete all as specified and as directed.
46Supply and fixing in repairscompressed glass wool 50 mm thick between solar energy collector panel copper tubes frame and aluminium body of panel including securing it on panel by means of necessary adhesives all as directed all as specified anddirected by Eng- in -charge.
47Supply and fixing in repairsaluminium sheet cover 1mm thick to protect glass wool on solar energy collector panel, fixing with frame of solar panel by means of screws all as directed and recommended by manufacturer.
48Supply and fixing in repairs hot water tank of capacity 500 ltrs,SS-304, including provision for inlet and out let of hot water, pressure release system.Hot water tank shall be made of 5 mm thick MS sheet dulyinsulated with glass wool / rock wool / Puf, aluminium / stainless steel cladding all around the tank and heat exchanger compartment etc complete. ( Location - 2 Coy).
49Supply and fixing in repairs hot water tank of capacity 1000 ltrs, SS 304, including provision for inlet and out let of hot water, pressure release system.Hot water tank shall be made of 5 mm thick MS sheet dulyinsulated with glass wool / rock wool / Puf, aluminium / stainless steel cladding all around the tank and heat exchanger compartment etc complete. ( Location - Clk Living).
50Supply and fixing in repairssteel water tubing 25 mm bore medium grade galvanised with all fittings for transportation of hot water from hot water tank to supply point duly insulated and insulation secured with tape and covered with aluminum sheet 1 mm thick all as recommended by the manufacturer.
51Supply and fill anti freezing chemical through heat exchanger tank of solar water heating sysytem. Making the whole system water tight and testing on completion.
52Supply & Fixingcollector dead flange for solar panel as per existing make and size.
53Supply & FixingTemprature Gauge incl all fixing arrangement.
54Supply & FixingMake up Tank complete with accessories.
55Supply & FixingFlexible HDPE corrugated pipe of 40mm dia for protection of LT Cable.
56Disconnecting the electrical connections of motor, water supply to the Pump andtaking out pump after disconnecting both motor and pump mechanically 220 /240HP capacity capacity - 75 Cum at 457 metres head installed at Main Pump House Gamber and transporting the same to an authorized workshop for following repairs:- Dismantling the complete pump carefully, taking out all impellers, impeller housings, bush bearings, oil rings, shaft with keys, shaft sleeves with nuts, balancing valve, com seating bush, neck rings and bushes, coupling set, gland and gland packing, logging ring, oil filter plug, water thrower, suction and delivery covers etc all as directed by Engineer-in-Charge and recommended by the manufacturer.After repairs the pump set is to be brought back at Pump house and installed, coupled with motor.All electrical, water and mechanical connections to be re-done all as directed. Note: All spares to be replaced shall be measured and paid separately under respective items.
57Bush bearing made out of bronze for Srl Item No 55.00
58Oil ring made out of brass for Srl Item No 55.00
59Shaft sleeve made out of stainless steel 410 grade for Srl Item No 55.00
60Balancing disc made out of bronze for Srl Item No 55.00
61counter Balancing disc made out of bronze for Srl Item No 55.00
62Neck ring made out of bronze for Srl Item No 55.00
63Center guide bush made out of bronze for Srl Item No 55.00
64Set of pins and Gaskets made out of Mild Steel for Srl Item No 55.00
65Gland box made out of Cast Iron including gland box studs with nuts and washers for Srl Item No 55.00
66Gland packing made out of Gr. Cotton for Srl Item No 55.00
67Shaft Check nut made out of bronze for Srl Item No 55.00
68Metal (bronze) filling in the worn out portion of impellers, turning and grinding the metal filled portions. Balancing the impeller by means of precision lathe machine for Srl Item No 55.00
69Body boring,mashiening and grinding etc after carry out balancing and repair of impellers etc for Srl Item No 55.00
70Disconnecting the electrical connections of motor, water supply to the Pump andtaking out pump after disconnecting both motor and pump mechanically 180HP capacitycapacity - 45.5 Cum at 458 metres head installed at Main Pump House Gamber and transporting the same to an authorized workshop for following repairs:-Dismantling the complete pump carefully, taking out all impellers, impeller housings, bush bearings, oil rings, shaft with keys, shaft sleeves with nuts, balancing valve, com seating bush, neck rings and bushes, coupling set, gland and gland packing, logging ring, oil filter plug, water thrower, suction and delivery covers etc all as directed by Engineer-in-Charge and recommended by the manufacturer.After repairs the pump set is to be brought back at Pump house and installed, coupled with motor.All electrical, water and mechanical connections to be re-done all as directed. Note: All spares to be replaced shall be measured and paid separately under respective items.
71Bush bearing made out of bronze for Srl Item No 56.00
72Oil ring made out of brass for Srl Item No 56.00
73Shaft sleeve made out of stainless steel 410 grade for Srl Item No 56.00
74Balancing disc made out of bronze for Srl Item No 56.00
75counter Balancing disc made out of bronze for Srl Item No 56.00
76Neck ring made out of bronze for Srl Item No 56.00
77Center guide bush made out of bronze for Srl Item No 56.00
78Set of pins and Gaskets made out of Mild Steel for Srl Item No 56.00
79Gland box made out of Cast Iron including gland box studs with nuts and washers for Srl Item No 56.00
80Gland packing made out of Gr. Cotton for Srl Item No 56.00
81Shaft Check nut made out of bronze for Srl Item No 56.00
82Metal (bronze) filling in the worn out portion of impellers, turning and grinding the metal filled portions. Balancing the impeller by means of precision lathe machine for Srl Item No 56.00
83Shaft with keys made out of steel 410 grade for Srl Item No 56.00
84Body boring,mashiening and grinding etc after carry out balancing and repair of impellers etc for Srl Item No 56.00
85Disconnecting the electrical connections of motor, water supply to the Pump andtaking out pump after disconnecting both motor and pump mechanically 100 / 125 HP capacity capacity - 45 Cum at 315 metres head installed at Radiana Pump House Subathu and transporting the same to an authorized workshop for following repairs:- Dismantling the complete pump carefully, taking out all impellers, impeller housings, bush bearings, oil rings, shaft with keys, shaft sleeves with nuts, balancing valve, com seating bush, neck rings and bushes, coupling set, gland and gland packing, logging ring, oil filter plug, water thrower, suction and delivery covers etc all as directed by Engineer-in-Charge and recommended by the manufacturer.After repairs the pump set is to be brought back at Pump house and installed, coupled with motor.All electrical, water and mechanical connections to be re-done all as directed. Note: All spares to be replaced shall be measured and paid separately under respective items.
86Bush bearing made out of bronze for Srl Item No 57.00
87Oil ring made out of brass for Srl Item No 57.00
88Shaft sleeve made out of stainless steel 410 grade for Srl Item No 57.00
89Balancing disc made out of bronze for Srl Item No 57.00
90counter Balancing disc made out of bronze for Srl Item No 57.00
91Neck ring made out of bronze for Srl Item No 57.00
92Center guide bush made out of bronze for Srl Item No 57.00
93Set of pins and Gaskets made out of Mild Steel for Srl Item No 57.00
94Gland box made out of Cast Iron including gland box studs with nuts and washers for Srl Item No 57.00
95Gland packing made out of Gr. Cotton for Srl Item No 57.00
96Shaft Check nut made out of bronze for Srl Item No 57.00
97Metal (bronze) filling in the worn out portion of impellers, turning and grinding the metal filled portions. Balancing the impeller by means of precision lathe machine for Srl Item No 57.00
98Shaft with keys made out of steel 410 grade for Srl Item No 57.00
99Body boring,mashiening and grinding etc after carry out balancing and repair of impellers etc for Srl Item No 57.00
100All as per item No 55.00 here-in-before but for 40 HP capacity capacity - 32 Cum at 140 metres head installed at PAO Pump House SubathuDismantling the complete pump carefully, taking out all impellers, impeller housings, bush bearings, oil rings, shaft with keys, shaft sleeves with nuts, balancing valve, com seating bush, neck rings and bushes, coupling set, gland and gland packing, logging ring, oil filter plug, water thrower, suction and delivery covers etc all as directed by Engineer-in-Charge and recommended by the manufacturer.After repairs the pump set is to be brought back at Pump house and installed, coupled with motor.All electrical, water and mechanical connections to be re-done all as directed. Note: All spares to be replaced shall be measured and paid separately under respective items.
101Ball bearing made out of bronze for Srl Item No 58.00
102Shaft sleeve made out of stainless steel 410 grade for Srl Item No 58.00
103Balancing disc made out of bronze for Srl Item No 58.00
104counter Balancing disc made out of bronze for Srl Item No 58.00
105Neck ring made out of bronze for Srl Item No 58.00
106Center guide bush made out of bronze for Srl Item No 58.00
107Set of pins and Gaskets made out of Mild Steel for Srl Item No 58.00
108Gland box made out of Cast Iron including gland box studs with nuts and washers for Srl Item No 58.00
109Gland packing made out of Gr. Cotton for Srl Item No 58.00
110Shaft Check nut made out of bronze for Srl Item No 58.00
111Metal (bronze) filling in the worn out portion of impellers, turning and grinding the metal filled portions. Balancing the impeller by means of precision lathe machine for Srl Item No 58.00
112Shaft with keys made out of steel 410 grade for Srl Item No 58.00
113Body boring,mashiening and grinding etc after carry out balancing and repair of impellers etc for Srl Item No 58.00
114All as per item No 55.00 here-in-before but for25 HP capacity capacity - 45 Cum at 70 metres head installed at Duty Coy / MES Wet CanteenPump House at Subathu .
115Ball bearing made out of bronze for Srl Item No 59.00
116Shaft sleeve made out of stainless steel 410 grade for Srl Item No 59.00
117Neck ring made out of bronze for Srl Item No 59.00
118Center guide bush made out of bronze for Srl Item No 59.00
119Set of pins and Gaskets made out of Mild Steel for Srl Item No 59.00
120Gland box made out of Cast Iron including gland box studs with nuts and washers for Srl Item No 59.00
121Gland packing made out of Gr. Cotton for Srl Item No 59.00
122Shaft Check nut made out of bronze for Srl Item No 59.00
123Metal (bronze) filling in the worn out portion of impellers, turning and grinding the metal filled portions. Balancing the impeller by means of precision lathe machine for Srl Item No 59.00
124Shaft with keys made out of steel 410 grade for Srl Item No 59.00
125Gland centre guide bush for Srl Item No 59.00
126All as per item No 55.00 here-in-before but for20 / 15 HP capacity (Make-Mather & Platt / KSB / Kirloskar ) capacity - 68 Cum at 35 metres head installed at Raw Water Pump House Gamber
127Ball bearing made out of bronze for Srl Item No 60.00 ( 6310 & 6306)
128Shaft sleeve made out of stainless steel 410 grade for Srl Item No 60.00
129Neck ring made out of bronze for Srl Item No 60.00
130Center guide bush made out of bronze for Srl Item No 60.00
131Set of pins and Gaskets made out of Mild Steel for Srl Item No 60.00
132Gland box made out of Cast Iron including gland box studs with nuts and washers for Srl Item No 60.00
133Gland packing made out of Gr. Cotton for Srl Item No 60.00
134Shaft Check nut made out of bronze for Srl Item No 60.00
135Metal (bronze) filling in the worn out portion of impellers, turning and grinding the metal filled portions. Balancing the impeller by means of precision lathe machine for Srl Item No 60.00
136Shaft with keys made out of steel 410 grade for Srl Item No 60.00
137All as per item No 55.00 here-in-before but for10HP capacity capacity - 45 Cum at 35 metres head installed at Raw Water Pump House and Back Wash Plant Gamber.
138Ball bearing made out of bronze for Srl Item No 61.00
139Shaft sleeve made out of stainless steel 410 grade for Srl Item No 61.00
140Neck ring made out of bronze for Srl Item No 61.00
141Center guide bush made out of bronze for Srl Item No 61.00
142Set of pins and Gaskets made out of Mild Steel for Srl Item No 61.00
143Gland box made out of Cast Iron including gland box studs with nuts and washers for Srl Item No 61.00
144Gland packing made out of Gr. Cotton for Srl Item No 61.00
145Shaft Check nut made out of bronze for Srl Item No 61.00
146Metal (bronze) filling in the worn out portion of impellers, turning and grinding the metal filled portions. Balancing the impeller by means of precision lathe machine for Srl Item No 61.00
147Shaft with keys made out of steel 410 grade for Srl Item No 61.00
148All as per item No 55.00 here-in-before but for 7.5 HP capacitycapacity - 13 Cum at 35 metres head) installed at Capts Colony Pump House/ Chil Chakkar.
149Ball bearing made out of bronze for Srl Item No 62.00
150Shaft sleeve made out of stainless steel 410 grade for Srl Item No 62.00
151Neck ring made out of bronze for Srl Item No 62.00
152Center guide bush made out of bronze for Srl Item No 62.00
153Set of pins and Gaskets made out of Mild Steel for Srl Item No 62.00
154Gland box made out of Cast Iron including gland box studs with nuts and washers for Srl Item No 62.00
155Gland packing made out of Gr. Cotton for Srl Item No 62.00
156Shaft Check nut made out of bronze for Srl Item No 62.00
157Metal (bronze) filling in the worn out portion of impellers, turning and grinding the metal filled portions. Balancing the impeller by means of precision lathe machine for Srl Item No 62.00
158Shaft with keys made out of steel 410 grade for Srl Item No 62.00
159All as per item No 55.00 here-in-before but for 5 HP capacity capacity - 45 Cum at 25 metres head installed at High Pressure Filter Plant Pump House Gamber .
160Ball bearing made out of bronze for Srl Item No 63.00
161Shaft sleeve made out of stainless steel 410 grade for Srl Item No 63.00
162Neck ring made out of bronze for Srl Item No 63.00
163Center guide bush made out of bronze for Srl Item No 63.00
164Set of pins and Gaskets made out of Mild Steel for Srl Item No 63.00
165Gland box made out of Cast Iron including gland box studs with nuts and washers for Srl Item No 63.00
166Gland packing made out of Gr. Cotton for Srl Item No 63.00
167Shaft Check nut made out of bronze for Srl Item No 63.00
168Metal (bronze) filling in the worn out portion of impellers, turning and grinding the metal filled portions. Balancing the impeller by means of precision lathe machine for Srl Item No 63.00
169Shaft with keys made out of steel 410 grade for Srl Item No 63.00
170Disconnecting the electrical and mechanical connections of motor, and taking out motor,240 / 220 HP capacity at Radiana Pump House. Transporting the same to an authorized workshop for following repairs:-(a) Dismantling burnt AC 3 Phase, 50 Hz,motor, 240 / 220 HP taking out all coils and re-winding the motor complete with same gauge of wire and same nos of turns. Heating, Baking and varnishing the winding complete. Re-assembling the motor and fixing back in position all as directed by Engr-in-Charge and recommended by the manufacturer.
171All as per item No 64.00 here-in-before but for, 180 HP capacity
172All as per item No 64.00 here-in-before but for, 100 / 125 HP capacity
173All as per item No 64.00 here-in-before but for, 40 HP capacity
174All as per item No 64.00 here-in-before but for, 25 HP capacity.
175All as per item No 64.00 here-in-before but for, 20 HP capacity.
176All as per item No 64.00 here-in-before but for, 15 HP capacity .
177All as per item No 64.00 here-in-before but for, 7.5 to 10 HP capacity .
178All as per item No 64.00 here-in-before but for, 5 HP capacity .
179S&F Coupling set suitable for 180/ 220 / 240 HP pump set made out of Cast Iron including bolts, nuts, washers & rubber bushes.(As per existing sample)
180S&F Coupling set suitable for 100/125 HP pump set made out of Cast Iron including bolts, nuts, washers & rubber bushes.(As per existing sample)
181S&F Coupling set suitable for 25/20/15 HP pump set made out of Cast Iron including bolts, nuts, washers & rubber bushes.(As per existing sample)
182S&F Coupling set suitable for 10 / 7.5 HP pump set made out of Cast Iron including bolts, nuts, washers & rubber bushes.(As per existing sample)
183Supply only rubber bushing L150 for 20 HP pump coupling complete all as specified.
184Supply only rubber bush for 180/220/240 HP pump coupling complete all as specified.
185Supply only alum sulphate (crystal) of best quality complete all as specified.
186Supply only Aquafit (Calcium Hypo Chloride) high strength granual disinfactant for treatment of drinking water complete all as specified.
187Amount of credit of Rs. 206453.00 for retrived old material as mentioned in Schedule "A" section-II of tender document in pdf form, will be deducted offline while acceptence of tender.