Provn Of Hard Standing Near Basic Ground Shed And Special Repairs To Bldg No T-26 At Lekhapani Mil Stn Under Ge Lekhapani Provn Of Hard Standing Near Basic Ground Shed And Special Repairs To Bldg No T-26 At Lekhapani Mil Stn Under Ge Lekhapani
Tender Overview
Project Description
Provn Of Hard Standing Near Basic Ground Shed And Special Repairs To Bldg No T-26 At Lekhapani Mil Stn Under Ge Lekhapani Provn Of Hard Standing Near Basic Ground Shed And Special Repairs To Bldg No T-26 At Lekhapani Mil Stn Under Ge Lekhapani
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Aug-2022 | AMENDMENT8665 | BOQ | 31-Aug-2022 |
| 2 | 31-Aug-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 07-Sep-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavationnot exceeding 30cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation getting out soft/ loose soil complete all as specified and directed. |
| 3 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm of soft loose soil complete all as specified and directed. |
| 4 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 5 | M&L Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolledusing power roller Exc 8 tonne and not exc 10 tonne to a true surface complete all as specified and directed. |
| 6 | Rolling and consolidating formation surfaces in cutting using power roller Exc 8 tonne and not exc 10 tonne to a true surface complete all as specified and directed. |
| 7 | Excavating in post holes (or similar holes) each n exc 0.5 cum by demolition of PCC floor of thickness overall 30cm and earth work in hard/dense soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,complete allasspecified and directed |
| 8 | M&L PCC (1:4:8), type D-2, (using 40mm graded stoneaggregates)as in foundations, filling, mass concrete etccomplete all as specified and directed. |
| 9 | M&L for providing RCC (1:1.5:3) type A-1 (using 20mmgradedstone aggregate) as in beams, cantilevers, bressumers, lintels over 1.5m span etc complete including necessary from work all as specified and directed. |
| 10 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers,. Shelves including supports, overhangs, etc.also splays between floors and beams, etc complete all as specified and directed. |
| 11 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. |
| 12 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM (1:6 ) complete all as specified and directd. |
| 13 | All as per Item No.12 above but except brickscomplete all as specified and directed |
| 14 | M&L Brick work with sub class old size \"B\" bricks, straight or curved on plan, exc 6m mean radius, built in CM (1:4)as in half brick complete all as specified and directed. |
| 15 | S&F Providing 30mm thick precast louvres and jallies of type B-0 (1:2:4) (12.5mm graded aggregate) set and jointed in cement mortar (1:4) complete all as specified and directed. |
| 16 | M&L PCC ( 1:3:6 ), type C-2 (using 40 mm gradedstone aggregate), as infoundations,filling msass concrete and sub base of floor,etc complete all as specified and as directed. |
| 17 | M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 18 | M&L Factory made chamfered edge cement concrete paver block with grey cement and no pigments any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade.manufactured with table vibratoy method using PU mould laid in required coloured and pattern laid over sand bed complete all as specified and directed by eng-in-charge. Note:-Sand bed shall be measured and paid separately |
| 19 | M&L Factory made chamfered edge cement concrete coloured paver block with grey cement andpigments any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade.manufactured with table vibratoy method using PU mould laid in required coloured and pattern laid over sand bed complete all as specified and directed by eng-in-charge. Note:-Sand bed shall be measured and paid separately |
| 20 | M&L Providing PCC (1:2:4) type B-1(using 20mm graded stone aggegate) as in copings including necessary form work complete all as specified and directed. |
| 21 | M&L for Providing machine pressed precast cement concrete (1:2:4) type B-1,(using 20mm graded stone aggegate) and set in CM (1:4) as in kerb stone slightlyrounded or chamfered on edgescomplete all as specified and directed. |
| 22 | Dismantling of Plain or corrugated steel sheet in roof coveringcomplete all as specified &directed. |
| 23 | M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 24 | M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 25 | Dismantiling timber 40 Sq.cm and over in section , in any position complete all as specified and directed. |
| 26 | Dismantling timber fillets, rails, posts, rafters, purlins, etc in unframed work under 40 Sqcm in section in any position complete all as specified and directed. |
| 27 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
| 28 | Fixing only Mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed. Note : Steel Obtained from the Dismantling shall be cleaned all the rusted surfaces and fabricated as per the site requirement and as directed by the Engr-in-Charge. |
| 29 | M&L Preparing old steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and as directed. |
| 30 | S&F Mild Steel work in tubular column including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St.-310 complete all as specified and directed. |
| 31 | S&F Mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923-1979 grade St-310 complete all as specified and directed. |
| 32 | S&F Rolled mild steel Plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachmentconforming to Fe:410-W(Gde-E-250) quality-A complete all as specified and directed. |
| 33 | M&L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, orscrewed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, longbut length of bolt exc 5cm but n exc 10cm long complete all as specified and as directed. |
| 34 | Taking down chowkhat n exc 1.5 sqmeach including making good dismantled portion in cement mortar 1:3 and cement concrete (1:2:4) complete all as specified and directed. |
| 35 | S&F pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., complete all as specified and as directed |
| 36 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as directed. |
| 37 | M&L TMTbars 10mm dia and over, cut to length, bent to shaperequired, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia orsecuring with clips complete all as specified and directed. |
| 38 | All as per Item No.37 above but TMTbars 6 to 8mm dia complete all as specified and directed. |
| 39 | All as per Item No.37 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 40 | M&L Rendering15mm thickin CM (1:4 ) on fair faces of brick work or concrete surfaces including finishingsurfaces complete all as specified and as directed. |
| 41 | M&L Rendering10mm thick CM (1:6) on fair faces of brick work or concrete surfaces including finishingsurfaces even and smoothwithout using extra cement complete all as specified & as directed. |
| 42 | M&L Preparation of newly plastered surface of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 43 | M&L Preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. |
| 44 | M&L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc, andbrushing neat cement slurry with 3.0 kg of cement per sq. metre complete all as specified and directedcomplete all as directed. |
| 45 | M & L for 75 mm thick PCC ( 1:2:4 ), type B-1 (using 20 mm gradedcrushed stone aggregate), as infloor finished even and smooth without using extra cement complete all as specified and as directed. |
| 46 | S&F 35 mm thick second class hard wood glazed and skelton door shutters ( factory made), open rebated and prepared to receive glass, guaze etc (without sash bars )edges of framing plain, chamfered or rounded fitted withcut and mitred beads for securing glass, etc.size of members of shutters as specified in SSR Part-1,section 8,clause 8.24 (a) complete fixed to frames all as specified and as directed. |
| 47 | S&F 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides andfixed to chowkats complete all as specified & directed. |
| 48 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified anddirected. |
| 49 | S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 50 | S & F for 200mmsize, aluminium anodised , barrel tower bolts of extruded section of ISI Mark and fixed completeall as specified and as directed. |
| 51 | S & F 150mm size aluminium handles, cast type, anodized(ISI Mark) and fixed complete all as specified and as directed. |
| 52 | M&L PCC (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) as fillingin pressed steel frames complete all as specified and directed. |
| 53 | M&L Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 54 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 55 | M&L for 75 mm thick PCC (1:3:6) type C-2, (using 40 mm gradedcrushed stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic filing in proportion of bitumen and sand 1:2 complete as specified and directed. |
| 56 | Taking down copper/aluminium point wiring, (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 57 | M & Lfor point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 2x1.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC casing & caping terminated in PVC boxsurface mounted of suitable size for fixing of switches, sockets, fan regulators etc for One light point controled by one one way 5 Amp switch complete all specified and as directed |
| 58 | All as per item No. 57 above but One fan point controlled by one , one way 5 Amp switch complete all specified and as directed. |
| 59 | All as per item No. 57above but One 5 pin socket outlet 05 Amp on independent board complete all specified and as directed. |
| 60 | All as per item No. 57 above but One 5 pin socket outlet 05 Amp on same board with other switches complete all specified and as directed. |
| 61 | All as per item No 57 here-in-before for one 15 Amps socket outlet but using 2.5 sq mm,copper conductor with 2.5 sq mm,PVC insulated single core cable for earth continuity conductor complete all specified and as directed. |
| 62 | S&F LED tube light fitting 4 ft. 1 x 18 watt with 230 volts, with bipin holder connector block, LED retrofit tube rod etc complete with all accessories internally pre-wired and fixed to walls/ceiling with screw on round PVC blocks including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 63 | S&F Ceiling fans complete with blades, down rods, electronicregulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 64 | S&F Fan regulators electronic stepped typecomplete all as specified and as directed. |
| 65 | S&F Switch piano flush type, 6 amps, 230V AC,single pole, one way complete all as specified and directed.. |
| 66 | S&F Switch socket combination multipurpose suitable for 2 pin and 3 pin 6 amp flush type complete all as specified and directed.. |
| 67 | S&F Switch socket combination multipurpose suitable for 2 in 1 , 3 pin 5 & 15amps flush type complete all as specified and directed. |
| 68 | S&F Socket outlet type 2 in 1 3/5 pin 5 Amps with other switchescomplete all as specified and as directed. |
| 69 | S&F Ceiling rose, 3 terminals, surface bakelite,PVC/Polycarbonate complete all as specified and directed. |
| 70 | M & L Sub main wiring complete with 2 runs of 6 sq mm,single core,PVC insulated,unsheathed cable,1100 volts grade,multi standard with copper conductor drawn through and including PVC casing caping and accessories on surface wall/floors/concealed etc. with one run of PVC insulated 6 sq mm copper conductor for earth continuity conductor including taking down old un serviceablewiring all as specified and directed.Note :- Threeruns of 6 Sqmm cable one run of casing capingshall be measured as one unit length. |
| 71 | S & F MCB SP 6to 32 Amps 240 volts complete all as specified and directed.. |
| 72 | S & F MCB SPN 6 Amps to 32 Amps 240 volts complete all as specified and directed. |
| 73 | S&F Single pole and neutral DB wall mounting type,240 Volts,8 Way with 200 Amps rated bus bar,double door suitable for fixing MCB\"s including connecting etc and taking down U/S DB ,main switch complete all as specified and directed. |
| 74 | M&L Earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways and testing on completion completeall as specified and directed. |
| 75 | S&F LED bldg security light fitting 48W watt with 230 Volts with IP 66.High Impact resistance complete with all accessories internally pre-wired and fixed to walls complete all as specified and directed. |
| 76 | Supply, lay and testing of cable XLPE Insulated screened PVC bedded galvanized steel strip or wire armored electric power cables(heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core laying in trenches/walls,etc complete all as specified and directed. |
| 77 | M&L for sand cushioning with a layer of sand 8cm thick before laying of cable and 10 cm thick after laying of cable in trenches complete all as specified and directed.Note: Only punned thickness shall be measured for payment purpose. |
| 78 | M&L Brick protection using old size sub class ‘B’new bricks, laid flat dry but jointed, laid length wiseperpendicular to theaxis of cable complete all as specified and directed. |
| 79 | S&F 40 mm dia GI tubing (light grade) complete with all fittings (ISI Marked) laid in trenches/fixed on pole/wall complete including taking down old unsv GI pipe complete all as specified and directed. |
| 80 | S & F Fan hooks made of MS clamp deformed to proper shape including nut & bolts and drilling/cutting roof as required at site and fixing fan hook with existing steel reinforcementcomplete all as specified and directed. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender