Purchase Of Equipment To Instrumentation Engineering Department Equipment For Instrumentation Engineering Lab Through Mhrd- 1 Hart Communicator With Configurator - Experimental Setup Documenting Process Calibrator Required To Familiarize Hart Communicato
Tender Overview
Project Description
Purchase Of Equipment To Instrumentation Engineering Department Equipment For Instrumentation Engineering Lab Through Mhrd- 1 Hart Communicator With Configurator - Experimental Setup Documenting Process Calibrator Required To Familiarize Hart Communicator Calibrator. Provides Sourcing / Simulation Signals Like Dc Voltage , Dc Current, Resistance, Frequency So That Transmitters Can Be Calibrated. Determines Type, Manufacturer, Model Tag Id With Hart Protocol Devices. Provides High Accuracy Measurement Mode To Measure Dc Voltage, Ac Voltage, Dc Current, Resistance And Frequency From Different Type Of Transmitters And Sensors For Calibration * Simultaneously Source &Measure Capabilities * Maintain And Calibrate Hart Transmitters * Sourcing Function Of Calibration I. Thermocouple Transmitter Ii. Rtd Transmitter * Dc Voltage Output To Calibrate Thermocouple Transmitter * Dc Current Output To Calibrate ( 4-20 ) Ma Devices * Resistance To Calibrate Rtd Transmitter * Frequency Is To Calibrate Frequency Devices Including Experiment Manuals And Documents 2 Smart Temperature Transmitter Calibration Set Up For Thermocouple Sensor ( To Calibrate Smart Temperature Transmitter For Different Ranges Of Temperature Using Tc Sensor And Perform A. Basic Setup B. Calibration ) The Setup Must Include The Following: 1.Smart Temperature Transmitter For T / C 2.Suitable Thermocouple Sensor Ranginng Room Temp. To 200 Degree Celcius 3. A Liquid Tempearture Bath ( Upto 200 Deg C , Closed Loop Control With Scr ) 4. The Smart Transmitter Must Be Compatible With Item-1 Communicator 5.Experiment Manuals And Documents 3 Smart Temperature Transmitter Calibration Set Up For Rtd Sensor ( To Calibrate Smart Temperature Transmitter For Different Ranges Of Temperature Using Rtd Sensor And Perform A. Basic Setup B. Calibration ) The Setup Must Include The Following: 1.Smart Temperature Transmitter For Rtd 2.Suitable Rtd Sensor 3. A Liquid Tempearture Bath ( Upto 200 Deg C , Closed Loop Control With Scr ) 4. The Smart Transmitter Must Be Compatible With Item-1 Communicator 5.Experiment Manuals And Documents 4 Smart Displacer Type Level Transmitter Calibration Set Up ( To Calibrate Smart Displacer Type Level Transmitter For Different Ranges Of Level And Performance ) The Setup Must Include The Following: 1.Smart Displacer Level Transmitter With Displacer. 2. Suitablepneumatic Test Pump Can Be Directly Connected To The Refference Proof. 3. The Smart Transmitter Must Be Compatible With Item-1 Communicator 4.Calibration Procedure Ready For Dry / Wet Calibration 5.Weight For Dry Calibration Should Be Provided 6.Experiment Manuals And Documents 5 Smart Differential Pressure Transmitter ( Dpt ) Calibration Set Up ( To Calibrate Smart Differential Pressure Transmitter For Different Ranges Of Differential Pressure And Performance& To Calibrate Smart Dp Type Level Transmitter For Different Ranges Of Dp And Performance ) The Setup Must Include The Following: 1.Smart Dp Transmitter 2. One Pressure Source 0.1 To 20 Bar Of Range Dp Range 10-1000Mmhz And Low Range 1-100Mbar 3. The Smart Transmitter Must Be Compatible With Item-1 Communicator 4. Suitable Pneumatic Test Pump ( Used For Testing & Calibration, 600 Psi Max Pressure ) 5.Experiment Manuals And Documents 6 Smart Pressure Transmitter Calibration Set Up : ( To Calibrate Smart Pressure Transmitter For Different Ranges Pressure And Performance ) The Setup Must Include The Following: 1.Smart Pressure Transmitter ( 0-10Bar ) 2.Experiment Manuals And Documents 3. The Smart Transmitter Must Be Compatible With Item-1 Communicator 4.Experiment Manuals And Documents 7 Smart Control Valve With Positionerset Up ( To Perform Control Valve Stroke Test Using 4-20Ma Source / Calibrate Control Valve Positioner Using 4-20Ma Source ) 1.One Linear Characteristics Control Valve With 15Mm Stroke 3 / 4 Sizewith Smart Positioner For Stroking 2.One Air Compressor ( 0-.07 ) Bar Range, Portable For Control Valve Air Input Supply With ( 0-10 ) Bar Pressure Gauge For Indication 3.Motor : Single Phase Suitable 4.One Safety Valve With Gauge 5.One Air Supply Regulator To Regulate The Control Valve Input Air Supply 6.Experiment Manuals And Documents 7. The Smart Positioner Must Be Compatible With Item-1 Communicator 8 Regulated Dualvariable Dual Power Supply ( -30 - 0-32V Dc Variable, 2 A ) 9 Multiprocess Control Trainer Setup: The Setup Must Include The Following: 1. Pressure Transmitter Mounted / Flow Transmitter ( Dpt ) With Rotameter Mounted Across The Pipe Line To Sence The Flow Of Water. 2. Tempature Sensor Of ( Rtd ) Type Mounted At The Outlet Of The Heater. 3. An Industrial Type Heater As A Heat Souce. 4. Fhp Pump For Water Circulation. 5. Ss Storage Tank Of 15 Litres Capacity. 6. Power Driver Provided To Vary The Pump Speed And Heater Power. 7. Orifice Plate For Pressure Drop Measurement. 8. Bourdon Tube Pressure Guage Is Provided To Measure The Tank Pressure. 9. Power Drive To Drive The Pump And Heater. 10. Usb / Serial Port For Data Aquisition And Necesary Software For Controlling The Process.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-Aug-2022 | IMPORTANT NOTICE | Other | 30-Aug-2022 |
| 2 | 29-Aug-2022 | CANCELLATION OF TENDER | Other | 30-Aug-2022 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Completed