| 1 | Purchase of Various Neruointerventional Neuroradiology, NSC on Two year Rate Contract basis |
| 2 | Super-selective high flow infusion catheters for Cerebral/SpinalAVMs (compatible with n-butyl cynoacrylates)-Flow guided |
| 3 | Super-selective high flow infusion catheters for Cerebral/SpinalAVMs (compatible with DMSO) with detachable tips: Microguidewire assisted |
| 4 | Super-selective high flow infusion catheters for Cerebral/SpinalAVMs (compatible with DMSO) without detachable tips: |
| 5 | Selective infusion micro catheters (compatible with particulate embolic agents e.g PVA particles) |
| 6 | Delivery Microcatheter |
| 7 | SPECIAL ATRAUMATIC MICROGUIDE WIRES WITH TORQUE DEVICE FOR USE WITH MICROCATHETERS: |
| 8 | SPECIAL ATRAUMATIC MICROGUIDE WIRES WITH TORQUE DEVICE FOR USE WITH MICROCATHETERS Regular Length |
| 9 | SPECIAL ATRAUMATIC MICROGUIDE WIRES WITH TORQUE DEVICE FOR USE WITH MICROCATHETERS Regular Length |
| 10 | SPECIAL ATRAUMATIC MICROGUIDE WIRES WITH TORQUE DEVICE FOR USE WITH MICROCATHETERS Extra Support Regular Length |
| 11 | SPECIAL ATRAUMATIC MICROGUIDE WIRES WITH TORQUE DEVICE FOR USE WITH MICROCATHETERS Exchange Length |
| 12 | SPECIAL ATRAUMATIC MICROGUIDE WIRES WITH TORQUE DEVICE FOR USE WITH MICROCATHETERS |
| 13 | SPECIAL MICROGUIDE WIRE DOCKING DEVICE-0.014” |
| 14 | Instant Electrothermally Detachable coils for intracranial aneurysm treatment: latest generation A-Regular sizes B-Nano sizes C-Large |
| 15 | Instant Mechanical Detachable coils for intracranial aneurysm treatment: Instant detachment Platinum coils latest generation A-Regular sizes B-Nano sizes C-Large |
| 16 | Instant electrothermally detachable Coated/Bioactive platinum coils |
| 17 | Instant Mechanical detachable coils for intracranial aneurysm treatment: Coated platinum coils |
| 18 | Instant Thermally Detachable coils with detachment sysstem length1cm-13cm |
| 19 | Instant Thermally Detachable coils with detachment sysstemlength 3cm-27cm |
| 20 | Instant Thermally Detachable coils with detachment sysstemlength 11cm-34cm |
| 21 | instant Thermally Detachable coils with detachment sysstem length 20cm-65cm |
| 22 | Pushable Coils to be used with Coil pushers |
| 23 | Catheters for Intracranial Aneurysm treatment two tip marker DMSO Compatible |
| 24 | Catheters for Intracranial Aneurysm treatment two tip marker Non DMSO Compatible |
| 25 | Selective infusion Micro catheters for deploying intracranial device: Stent |
| 26 | Selective infusion Micro catheters for deploying intracranial device: Flow diverters-0.027”, 0.044\" |
| 27 | INTERMEDIATE CATHETERS-Distal access catheters |
| 28 | 0.070”, 0.071” |
| 29 | B-0.074” |
| 30 | B-0.078” |
| 31 | 0.088” |
| 32 | Diameter: 0.086, 0.100 |
| 33 | Accessories for detaching coils: power supply, connecting cables; batteries & patient return electrodes. |
| 34 | Coil pushers |
| 35 | Poly vinyl alcohal (PVA) praticlesfor pre-operative Tumour embolization and treatment of epistaxis: |
| 36 | Detachable balloon microcatheters with detachable balloons: |
| 37 | Detachable balloons: |
| 38 | Electrolytically Detachable Intracranial Stents for stent assisted coiling of aneurysms (A- Open cell design) |
| 39 | Detachable Intracranial Stents for stent assisted coiling of aneurysms: Atleast partially retrievable B- Closed cell design |
| 40 | Electrolytically Detachable Intracranial Stents for stent assisted coiling of aneurysms:C-Completely retrievable |
| 41 | Intracranial Stents for stent assisted coiling of aneurysms D-Hybrid cell design |
| 42 | Intracranial Stents for stent assisted coiling of aneurysms closed cell Design. |
| 43 | Intracranial Stents for stenting of ICAD |
| 44 | Endoluminal embolization device 48 wire braid |
| 45 | Endoluminal embolization device 64 wire braid |
| 46 | Endoluminal embolization device 48 wire Nitinol braid |
| 47 | Endoluminal embolization device 48 hybrid nitinol wires |
| 48 | Endoluminal embolization device diameter 3.5-6mm |
| 49 | Baby sizes (endoluminal embolization device) |
| 50 | Endoluminal embolization device 48 braided wires |
| 51 | Intrasaccular Devices48 wires |
| 52 | 144-180 wires nitinol wires |
| 53 | 144 wires |
| 54 | PIGTAIL CATHETER - FDA APPROVED |
| 55 | DIAGNOSTIC CEREBRAL ANGIOGRAPHY CATHETER- FDA APPROVED |
| 56 | DIAGNOSTIC CEREBRAL ANGIOGRAPHY CATHETER- CE APPROVED |
| 57 | DIAGNOSTIC CATHETER FOR SPINAL ANGIOGRAPHY - FDA/CE APPROVED |
| 58 | Balloon tipped guiding catheter |
| 59 | Proximal Protection devices during Carotid angioplasty and stenting: |
| 60 | Distal Protection device for Carotid angioplasty and stenting: |
| 61 | PUNCTURE NEEDLE FOR VASCULAR ACCESS IN ADULTS |
| 62 | MICROPUNCTURE NEEDLE FOR VASCUALAR ACCESS IN CHILDREN |
| 63 | SHORT INTRODUCER SHEATH FOR ADULTS (Size 4Fr.-10Fr.) (Standard Length) |
| 64 | SHORT INTRODUCER SHEATHFOR PAEDIATRIC. |
| 65 | LONG INTRODUCER SHEATH (> 50 cm-<90CM) (Size 5Fr.-7Fr.) |
| 66 | LONG INTRODUCER SHEATH 80cm long |
| 67 | LONG INTRODUCER SHEATH 90cm long |
| 68 | LONG INTRODUCER SHEATH 100cm long |
| 69 | Lumen Delivery Catheter Proximal/Disatl 6fr OD with 0.070 ID |
| 70 | Lumen Delivery Catheter Proximal/Disatl 6f-5fr OD with 0.053 ID |
| 71 | Delivery assist catheter Distal OD 2.0F-2.7F. Proximal OD 2.5F-3.0F |
| 72 | HYDROPHILIC DIAGNOSTIC GUIDE WIRE -(REGULAR LENGTH, REGULAR STIFFNESS) |
| 73 | HYDROPHILIC DIAGNOSTIC GUIDE WIRE –(EXCHANGE LENGTH, REGULAR STIFFNESS) |
| 74 | HYDROPHILIC DIAGNOSTIC GUIDE WIRE -(REGULAR LENGTH, EXTRA-STIFF) |
| 75 | HYDROPHILIC DIAGNOSTIC GUIDE WIRE - (EXCHANGE LENGTH, EXTRA-STIFF) |
| 76 | PTFE COATED DIAGNOSTIC GUIDE WIRE - (REGULAR LENGTH, EXTRA-STIFF SHAFT STRENGTH) -AMPLATZ TYPE |
| 77 | ANGIOPLASTY INFLATION DEVICE- ANALOG DISPLAY |
| 78 | Extracranial Stents for use in carotid: Open cell design |
| 79 | Extracranial Stents for use in carotid: Closed cell design |
| 80 | Extracranial Stents for use in carotid: Hybrid cell design |
| 81 | Extracranial Stents for use in carotid: Dual layered |
| 82 | Balloon mounted Extracranial bare metal Stents for use in carotid & vertebral arteries & osteal lesions: A-Rapid exchange (monorail) |
| 83 | Balloon mounted Extracranial bare metal Stents for use in carotid & vertebral arteries & osteal lesions: B-Over-the-wire system |
| 84 | Intracranial Stents for treatment of atherosclerotic stenotic lesions:A-Self expandible |
| 85 | Intracranial Stents for treatment of atherosclerotic stenotic lesions of intracranial vessels: B-Balloon premounted |
| 86 | Stent-graft (covered stent) for pseudoaneurysm or fistula treatment: Monorail |
| 87 | Stent-graft (covered stent) for pseudoaneurysm or fistula treatment: Over-the-wire system |
| 88 | A-Balloon angioplasty catheters for intracranial use-: |
| 89 | Balloon angioplasty catheters for extra-cranial use:- |
| 90 | Double lument balloon for angioplasty and stent delivery |
| 91 | Occlusion balloons for flow modification/assistance for treatment of wide-neck intracranial aneurysm: Single lumen Compatible with 0.010” microguidewire |
| 92 | Occlusion balloons for flow modification/assistance for treatment of wide-neck intracranial aneurysm: Single lumen Compatible with 0.014” microguidewire |
| 93 | The single lumen remodeling balloon catheters |
| 94 | Double lumen occlusion balloons for flow modification/assistance for treatment of wide-neck intracranial aneurysm: |
| 95 | Endo-vascular snares for retrieval of intravascular foreign objects: |
| 96 | Accessories: Should contain the following items•Short and long connecting tubes with 3- ways. •Guide wire insertion needle•Guide wire Torquer for 0.007-0.018” MICROGUIDEWIRES•Guide wire Torquer for 0.025”-0.035”, 0.038” guidewires•One-way, three way stop cock•100-150 cm long extension tubing for measurement of pressures (pressure monitoring line) |
| 97 | Large bore contrast tubing (with flow regulating knob & high pressure resistant) |
| 98 | Disposable syringes |
| 99 | Luer lock three piece disposable/glass syringes |
| 100 | Luer lock three piece disposable/glass syringes having markings up to 50ml for contrast injection |
| 101 | Lypholised poppy seeds oil |
| 102 | Infusion tubing sets for arterial pressure infusion |
| 103 | Infusion tubing sets for arterial pressure infusion |
| 104 | Puncture needle for vascular access in adults |
| 105 | Micropunctureneedle for vascular access in children |
| 106 | Angioplasty Inflation Device- |
| 107 | TUOHY BORST WITH SIDE ARM (HAEMOSTATIC Y-CONNECTOR) |
| 108 | TUOHY BORST-DOUBLE WITH SIDE ARM (HAEMOSTATIC DOUBLE Y-CONNECTOR) FOR CO-AXIAL/TRI-AXIAL SYSTEMS |
| 109 | ARTERIAL PUNCURE CLOSURE DEVICES- |
| 110 | Large bore aspiration catheter for thrombectomy· 0.071 ID |
| 111 | Large bore aspiration catheter for thrombectomy · 0.068\" ID |
| 112 | Large bore aspiration catheter for thrombectomy ·0.070 ID |
| 113 | Reperfusion catheters |
| 114 | Connecting Tube |
| 115 | Collection Canister & Intermediate Tubing |
| 116 | Mechanical thrombectomy devices for Flow Restoration in Acute Ischemic Stroke |
| 117 | Mechanical thrombectomy devices for Flow Restoration in Acute Ischemic Stroke |
| 118 | Mechanical thrombectomy devices for Flow Restoration in Acute Ischemic Stroke |
| 119 | EVOH (ethylene vinyl alcohol) Suspended tantalum powder |
| 120 | EVOH (ethylene vinyl alcohol) Suspended micronized tantalum powder |
| 121 | Pure Liquid embolic agent n-hexyl cyanoacrylate monomers |
| 122 | Pure Liquid embolic agent · n-butyl cyanoacrylate (NBCA) |
| 123 | Tantalum micronised particles |