}

Rate Contract For Upkeep / Maintenance Of 66-33 / 11 Kv Receiving Stations Along With Their 66 / 33 Kv Lines And Fabrication & Handling Of Material Of Divisional Store Under The Jurisdiction Of Sub Transmission Division, Jpdcl, Kathua For The , kathua-Jammu And Kashmir

Power Development Department has published Rate Contract For Upkeep / Maintenance Of 66-33 / 11 Kv Receiving Stations Along With Their 66 / 33 Kv Lines And Fabrication & Handling Of Material Of Divisional Store Under The Jurisdiction Of Sub Transmission Division, Jpdcl, Kathua For The . Submission Date for this Tender is 27-08-2022. Coats and Jackets Tenders in kathua Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

33521713
Rate Contract For Upkeep / Maintenance Of 66-33 / 11 Kv Receiving Stations Along With Their 66 / 33 Kv Lines And Fabrication & Handling Of Material Of Divisional Store Under The Jurisdiction Of Sub Transmission Division, Jpdcl, Kathua For The
Open Tender
Indian
Jammu And Kashmir
kathua
27-08-2022

Tender Details

Rate Contract For Upkeep / Maintenance Of 66-33 / 11 Kv Receiving Stations Along With Their 66 / 33 Kv Lines And Fabrication & Handling Of Material Of Divisional Store Under The Jurisdiction Of Sub Transmission Division, Jpdcl, Kathua For The Year 2022-23 Or Till The Next Contract.- 1 Erection Of 16 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 2 Erection Of 13 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 3 Erection Of 11 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 4 Erection Of 11 Mtr Long Pcc Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 5 Erection Of 9 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 6 Erection Of 9 Mtr Long Pcc Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 7 Painting Of 16 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 8 Painting Of 13 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 9 Painting Of 11 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 10 Painting Of 09 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 11 Cement Bottoming In 1:2:4 Mix Including Excavation And Form Work As Per Rec Standards. ( 16 / 13 / 11 / 9 Mtr Long Poles ( Complete Job ) 12 Fixing Of Galvanisedspiral Earthing Of Swg No. 8, G.I Wire Of 115 Turns Confirming To Rec-J1 Construction Standard, ( J1 ) 13 Fixing Of 66 / 33Kv Galvanised Guy Set ( Guy Wire, Guy Rods, Turn Buckle Plate , Guy Insulators ) Confirming To Is 2141 / 1979 Or The Latest Version Thereof Including Digging Of Pits & Refilling 14 Collection Of Snapped Acsr Cond. And Re-Stringing, Tensioning , Binding Of Acsr Conductor, ( 100Mm2 Acsr Conductor ) 15 Collection Of Snapped Acsr Cond. And Re-Stringing, Tensioning , Binding Of Acsr Conductor, ( 150Mm2 Acsr Conductor ) 16 Collection Of Snapped Acsr Cond. And Re-Stringing, Tensioning , Binding Of Acsr Conductor, ( 200Mm2 Acsr Conductor ) 17 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 16 Mtr. Long ) Up To Distance Of 50 Mtr 18 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 13 Mtr. Long ) Up To Distance Of 50 Mtr 19 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) Up To Distance Of 50 Mtr 20 Dismantling Of Pcc Pole Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) Up To Distance Of 50 Mtr 21 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) Up To Distance Of 50 Mtr 22 Dismantling Of Pcc Pole Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) Up To Distance Of 50 Mtr 23 Dismantling Of Three / Four Pole Structure, Opening Of Channels, Crossarms, Angles ( Complete Job. ) 24 Dismantling Of Two Pole Structure, Opening Of Channels, Crossarms, Angles ( Complete Job. ) 25 Straightening Of Tilted Steel Tubular Pole ( 16 Mtr. Long ) 26 Straightening Of Tilted Steel Tubular Pole ( 13 Mtr. Long ) 27 Straighteningof Tilted Steel Tubular Pole ( 11 Mtr. Long ) 28 Straighteningof Tilted Pcc Pole ( 11 Mtr. Long ) 29 Straighteningof Tilted Steel Tubular Pole ( 9 Mtr. Long ) 30 Straighteningof Tilted Pcc Pole ( 9 Mtr. Long ) 31 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 16 Mtr. Long ) Up To Distance Of 50 Mtr 32 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 13 Mtr. Long ) Up To Distance Of 50 Mtr 33 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) 34 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) Up To Distance Of 50 Mtr 35 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 16 Mtr. Long ) 36 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 13 Mtr. Long ) 37 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) 38 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) 39 Extra Carriage From Dumping Site, ( 16 Mtr. Long ) Up To Site Of Work 1St 100 Mtr 40 Extra Carriage From Dumping Site, ( 13 Mtr. Long ) Up To Site Of Work Ist 100 Mtr 41 Extra Carriage From Dumping Site, ( 11 Mtr. Long ) Up To Site Of Work Ist 100 Mtr 42 Extra Carriage From Dumping Site, ( 9 Mtr. Long ) Up To Site Of Work Ist 100 Mtr 43 Unloading Of Steel Of Sorts , ( Steel ) 44 Loading Of Steel Of Sorts , ( Steel ) 45 Unloadingof Conductor Reels, ( 100Mm² / 150Mm² / 200Mm² Acsr Conductor ) 46 Loadingof Conductor Reels, ( 100Mm² / 150Mm² / 200Mm² Acsr Conductor ) 47 Fixing Of 66-33 Kvdiscinsulator ( 70 Kn ) 2008 Standards, ( Porcelain ) 48 Fixing Of 66-33 Kv Disc Fitting ( 70 Kn ) 2008 Standards, ( Polymer ) 49 Fixing Of 66-33 Kv Insulators ( 10 Kn ) Standards, ( Porcelain ) 50 Fixing Of 66-33 Kv Pin Insulators ( 10 Kn ) Suitable For 100 / 150 / 200Mm² Acsr Conductor. 51 Replacement / Fixing Of 66-33 Kvtension Fittings ( Socket & Ball Type Or T&C Type ) For Acsr 52 Replacement / Fixing Of 66-33 Kv Tension Fittings ( Socket & Ball Type Or T&C Type ) For Acsr 150M² 53 Replacement / Fixing Of 66-33 Kv Tension Fittings ( Socket & Ball Type Or T&C Type ) For Acsr 200M² 54 Straighteningof X-Arms Of Different Sizes ( 100X50x50x6 Mm Channel Iron, 50X50x6mm Angle Iron ) Duly Painted With One Coat Of Red-Oxide And Two Coats Of Silver Paint Fixing With Different Sizes And Sorts Of Nuts, Bolts And Washers, ( Channel Iron X-Arms, Angle Iron-X-Arms, Pole Tops ) 55 Straighteningof Angle Ironof Different Sizes ( 65X65x6 Mm Channel Iron, 50X50x6mm Angle Iron 56 Repair And Re-Erection Of Cradle For Guard Netting With Gi Wire 8No Including Wire Binding, Cutting / Bending Of Gi Wireas Per Rec Standards 57 Branch Cutting, 66- 33 Kv Lines 58 Removing Of Wild Climbers / Vegetation Around 66 / 33 Kv Poles 59 Removing Of Wild Climbers / Vegetation Around 66 / 33 Kv Tower 60 Removing Of Wild Climbers From Top Of 66-33 Kv Lines. 61 Removing Of Wild Climbers From Peak, Cage, Cross Arm Of 66-33 Kv Old Tower Line 62 Patrolling Of 66 / 33 Kv Line ( Routine / Under Fault ) 63 Tightening Of Loose Guys 64 Dismantling & Re-Erection Of Damaged Guys Including Digging Of Pit & Refilling The Same 65 Replacement Of Damaged Disc Insulator In Tension String 66 Replacement Of Cross Arms Of Sizes 100X50x6 67 Replacement Of Angle Iron Of Sizes ( 65X65x6, 50X50x6 ) 68 Replacement Of Pin Insulator On Four / Three / Double Pole Structure 69 Replacement Of Pin Insulator On Single Pole Structure 70 Replacement Of Worn-Out / Damaged Jumper Of 66-33 Kv Towerlines 71 Replacement Of Disc Insulator, Suspension Fitting Of 66-33 Kv Towerlines 72 Replacement Of Worn-Out / Loose / Damaged Jumper Of 66-33 Kv Lines ( Sets Of3 Nos ) 73 Local Earthing Of 66 / 33 Kv Lines By Way Of Using Discharge / Earth Rods At Faulty Site To Avoid Accident Due To Any Induction While Working On Line. 74 Tightening / Restringing Of Loose Acsr Dog 100 Mm2 75 Tightening / Restringing Of Loose Acsr Wolf 150 Mm2 76 Tightening / Restringing Of Loose Acsr Panther200 Mm2 77 Dismantling & Re-Erection Of Acsr Dog 100Mm2 Including Collection Of Dismantled Conductor , Making Of Small Bundles And Its Carriage 78 Dismantling & Re-Erection Of Acsr Wolf 150Mm2 Including Collection Of Dismantled Conductor , Making Of Small Bundles And Its Carriage 79 Dismantling & Re-Erection Of Acsr Panther 200Mm2 Including Collection Of Dismantled Conductor , Making Of Small Bundles And Its Carriage 80 Dismantling Of Stay Sets Complete 81 Upkeep / Maintenance Of 66-33 / 11 Kv Receiving Sub Stations A ) Routine Maintenance Of 66 Kv Outdoor Sf6 By Way Of Tightening Of Loose Nuts And Bolts, Greasing / Lubrication Of Movable Parts, Checking The Movable Alignment Of Different Phases, Cleaning Of Insulating Chambers, Etc 82 33 Kv Vcb Repairs & Renovationby Way Of B ) Setting Of Mechanical Assembly / Replacement Of Damaged Spring / Repair Of Locking & Charging System 83 C ) Replacement Of Tripping Coil / Closing Coil 84 D ) Replacement Of Damaged Vacuum Interrupter 85 E ) Replacement Ofbushing Including Clamps 86 66 Kv C&R Panel: Replacement Of Different EquipmentSa ) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch , Selector Switchidentification Of Panel Wiring Faults & Its Rectification 87 33 Kv C&R Panel: Replacement Of Different EquipmentSa ) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch , Selector Switchidentification Of Panel Wiring Faults & Its Rectification 88 B ) Replacement Of Different Relays - Mitnumerical Relay / Electro-Mechanical Relay / Master Trip Relay / Differential Relay / Auxiliary Relay Etc. 89 Installation, Testing, Commissioning Of 66-33 Kv Control Relay Panels ( Complete Job ) 90 Complete Testing Of Relays Setting Of Testing Kit, Interconnection Between Various Points Of Panel With Respect Tosecondary Injection Key On Various Current Taps, Recording The Observation Thereof. All Modifications Necessary To Achieve Desired Results. 91 Control Cable Replacement Of Damagedcontrol Cables Of All Typesincluding Binding With Pvc Belts / Binding Wire, Peeling Of Insulation And Fixing Of Proper Size Thimble Connecting The Cable After Identification Of Each Core To Both Ends I.E. Panel To Cts / Panel Topts / Panel To Breaker And Making Functional Of 33 Kv Outdoor Breakers, Protection , Alarms, Annunciation ( Complete Job ) 92 Upkeep Of Earthing Of Aux. Transformer 93 Upkeep Of Earthing Of Power Transformer 94 Upkeep Of Earthing Of 66 / 33 / 11 Kv La 95 Providing Of Extra Earthing For Improvement Purpose ( Complete Job ) 96 Upkeep Of Earth Mat Of Out Door Yard 97 Replacement Of Damaged Earth Mesh In Sub-Station As Per Approved Map & Design. 98 Excavation Of Trenches Of 0.6 Mtr Depth And 2.0 Mtr Wide Mtr In Normal Soil / Hard Soil 99 Repairing / Laying Of Ms Flat And Ms Rod In Deep Excavated Trench And Welding Of Ms Flat & Ms Rod With Mesh. 100 Repairing Of Earthing With Spikes Of Ms Rod 20Mm, 3 Mtr In Length As Per Rec Drawing 101 66-33 / 11 Kv Power Transformera ) Opening Of Transformer Tank Top Cover To Prevent Oil Leakage From Top ( If Required To Facilitate Maintenance Of Transformer After Removing The Required Accessories ) , , Draining / Re-Filling Of Required Oil, Change Of Gaskets Of Valves / Radiators / BuchholzS Relay Radiators Valves Of Power Transformer Of Capacity: 3.15 Mva To 20 Mva 102 B ) Replacement Of Silica Gel 103 C ) General Inspection By Through Inspection Of Each Individual Parts, Ratio Test By Applying Voltage On Hv Side And Measuring Lv Voltage On Various Tap Positions, Checking Of Buchholz Relay, Surge Relay Conservator, Sensors, Measurement Of 1R-Value Dialectic Strength Of Oil, Cleaning Of Power Transformer Etc 104 D ) Replacement Of Any One Of The Following I.E. Temperature Indicators, Gas Operated BuchholzS Relay, Oil Temperature Indicator, Winding Temperature Indicator Etc 105 E ) Preventing Of Leakage By Changing Main Gaskets After Removing The Old Gasket, Replacement Of Hv / Lv Busing & Bush Rod, Ring And Rubber Washers ( Complete Job To Prevent Leakages ) 106 F ) Cleaning Of Scale Deposited Over The Body And Radiators Of The Power Transformer With Thinner / Detergent And De-Rusting In Perfect Manner. ( Routine Work ) 107 G ) Cleaning Of Lv / Hv Bushings Of Power Transformer ( Routine Work ) 108 H ) Replacement Of Bus Bars Ofpower Transformer 109 I ) Replacement Of Lv / Hv Clamps Of Power Transformer 110 Oil Topping Of Power Transformer 10 Mva To 20 Mva 111 Oil Topping Of Power Transformer 4 Mva To 6.3 Mva 112 Oil Topping Of Power Transformer 3.15 Mva 113 Recording Of Ir Values Of Transformers 114 Installation, Testing And Commissing Of Power Transformer 66-33 / 11 Kv Installation Of Lv / Hv Bus Bars With Proper Care, Of Transformer For Any Leakagecommissioning Of Power Of Transformers By Applying Low Voltageapproximately Equal To Impedance Voltage On Hv Side And Short Circuiting The Lv Terminals, Energizing The Transformer By Applying Required Primary Voltage To It & Keeping The Transformer On No Load To Observe The Behaviour Of Transformer, Setting On 25% Of The Load On The Transformer For A Period Of At Test 6 Hours And Observation Of Oil Including Temperature, Increase The Transformer Is Fully Loaded And Topping Of Oil.A ) 20 Mva 115 B ) 10 Mva 116 C ) 6.3 Mva 117 D ) Upto 5 Mva 118 Checking And Tightening Of Jumpers, Droppers In 66 / 33 Kv Outdoor Yard 119 Replacement Of T / Pg Clamps 120 Replacement Of Disc Insulators Including Its Hardware. 121 66 / 33 Kv La & 11 Kv Stn. Type Lareplacement Of 66 Kv, 33 Kv & 11 Kv Lightening Arrestor Including Jumpering And Earth Connecting In All Respect. A ) 66 Kv La 122 B ) 33 Kv La 123 B ) 11 Kv La 124 Separate Pipe Earthing / G.I Rod Earthingas Per Rec Drawing 125 Replacement Of Pipe Earthing / Rod Earthing With New One 126 Installation, Testing And Commissioning, Replacement Of 66 Kv Isolators 127 Installation, Testing And Commissioning, Replacement Of 33 Kv Isolators 128 Replacement Of11 Kv Isolators 129 Repair & Renovationof 66 / 33 Kv And 11 Kv Isolators Including Setting Right Its Alignment For Proper Operation, Lubrication / Greasing Of Jaws, Bearings OperatingS Handle Etc ( Complete Job ) 130 Replacement Of Worn-Out / Heated Pad Clamp / Isolator Clamps Of 66 / 33 / 11 Kv Isolator By Way Of Dismantling. Drilling Of Holes On New And Fixing ( Complete Job ) 131 Repair & Renovationof Isolator Jaws 66 / 33 Kv And 11 Kv Isolators. ( Complete Job ) 132 Replacement Of Post Insulator / Tendon Pipes / Operating Box By Way Of Dimentalling, Necessary Fabrication Where Ever Required For Proper Operation Of 66 / 33 / 11 Kv Isolators. 133 66-33 Kv Ctsinstallation, Testing And Commissioning Of 66-33 Kv Cts ( Of All Ratios ) Complete Job 134 66-33 Kv Ctsrepairs & Renovation Of 66 / 33 Kv Cts By Way Of Replacing Shorting Strips, Connecting Rod, Transformer Oil, Damaged Insulator ( CtS Of All Ratios ) 135 Replacement Of 66 Kv Outdoor Type Ct Of Different Ratio And Dismantling Of Damaged Ct ( CtS Of All Ratios ) 136 Replacement Of 33 Kv Outdoor Type Ct Of Different Ratio And Dismantling Of Damaged Ct ( CtS Of All Ratios ) 137 Oil Topping Of 66 / 33 Kv Ct & Pt By Way Of Opening Of Top Cover And Refixing With New Gaskets If Necessary And Preventing Of Oil Leakages If Any. ( Complete Job ) 138 66-33 Kv Ptsinstallation, Testing And Commissioning Of 66-33 Kv Pts ( Complete Job ) 139 66 Kv Ptsreplacement Of 66 Kv Outdoor Type Pt And Dismantling Of Damaged Pt, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure. 140 33 Kv Ptsreplacement Of 66 Kv Outdoor Type Pt And Dismantling Of Damaged Pt, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure 141 66 Kv Post Insulatorreplacement Of 66 Kv Post Insulatorand Dismantling Of Damaged Pi, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure. 142 33 Kv Post Insulatorreplacement Of 33 Kv Post Insulatorand Dismantling Of Damaged Pi, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure. 143 Cleaning Of Porcelain Bushing, Tightening Ofpt / Ct Clamps, Derusting & Painting Of Body Of 66 / 33 Kv Pts & Cts 144 Tightening Of Nuts & Bolts, Replacement Of Oval Thread Bolts, Chipping By Way Of Welding To The Bolts After Tightening In A Single Bay 145 Painting With Mix Red Oxide Paint Two Coats Of Approved Make On Steel Works After Cleaning With Wire Brush / Sand Paper 146 Painting Of Steel Structure Erected In Outdoor Yard With Aluminium Paint Two Coats With Approved Brand Andfixture To Given An Even Surface 147 Battery Banka ) Repair & Maintenance Of Battery Set Including Maintaining Specific Gravity, Electrolyte Level, Cleaning, Checking, Tightening Of Battery Terminals In All Respects It Includes Measuring Voltage Of Each Battery. 148 B ) Tightening Of All Nut And Bolts, Replacement Of Damaged Battery Cells 149 C ) Installation, Testing And Commissioning Of Battery Bank ( Complete Job ) 150 Battery Chargerrepair / Renovation Battery Charger For Proper Functioning By Way Of Replacement Of Rectifier Unit, Ammeter, Voltmeter, Mcb, Cooling Fan, Led Indications, Buzzer Alarms For Ov / Uv Etc ( Complete Job ) 151 Repair And Maintenance Of Dc Board, Identification Of Fault In Respect Of Cableand Its Replacement, Replacement Of Damaged Mccb, Kit Kat, Bus Bar & Other Allied Job. 152 Repair And Maintenance Of Ac Board, Identification Of Fault In Respect Of Cableand Its Replacement, Replacement Of Damaged Mccb, Kit Kat, Bus Bar & Other Allied Job. 153 Installation, Testing And Commissioning Of Battery Charger ( Complete Job ) 154 Deweeding Of Vegetation In Outdoor Yardremoving Of Stone Metal, Deweeding Of Unwanted Vegetation, Spreading Of Stone Metal Collected Earlier For Removal Of Vegetation, Levelling The Area With Existing Stone Metal 155 Providing Of Additional Stone Metal And Its Carriage And Laying In Outdoor Yard, This Including Breaking Of Stones Complete Job. 156 Cleaning Of Control Room, Removing Dirt & Dust From The Panels, Walls, Cleaning Of Fixtures ( For One Bank ) 157 Painting Of Internal / External Walls And Roof By Approved Brand Of Oil Based Distemper 158 Painting Of Door And Window Panels Of Control Room By Approved Brand Of Paint 159 Repairs & Renovation Of 11 Kv Vcb, By Way Of Replacement Of A ) Grid-Spout Assembly 160 B ) Replacement Of Damaged Cts Of Different Ratio Testing The Ct With The Help Of Primary Injection Set Fixing In Pannel, Fixing The Secondary Connection After Assessing The Load ( Complete Job ) 161 C ) Thorough Checking Of Control Wiring Circuits, Replacement Of Damaged Wire If Any, Replacement Of Terminal Plates, Tripping Circuits, Close / Trip Switch, Ammeter Switch, Replacement Of Voltmeter & Ammeter . 162 D ) Replacement Of 11 Kv Damaged Pt 163 E ) Replacement Of Blown Fuses, Checking The Pt Terminal With Respect Of 11 Kv Bus Bar Complete Job. 164 F ) Replacement Of Trip / Close Coil 165 G ) Replacement Of Trivector Meter On 11 / 33 / 66 Kv Panels 166 Installation, Testing And Commissioning , Replacement Of Lt Cabele 167 11 Kv Power Cables / 33 Kv Power Cables / 66 Kv Power Cablesa ) Identification Of Damaged Portion Of Cable, Tracing Of Cable, Remove Cable From Trench, Carriage And Laying Of Cable ( Complete Job ) Including Cleaning Of Cable Trenches. 168 B ) Replacement Of Damaged Cable Of Sizes 169 Replacementof Termination Kits Of Different Sizes, Connecting The Cable With Panel And Outgoing Structures After Crimping Of Lugs Fixing With Nuts And Bolts, Checking Of Earth Point, Connecting The Earthing Point Of Cable With Existing Earthing System A ) 11 Kv Indoor Termination Kit ( 1-Phase / 3 Phase ) 170 B ) 11 Kv Outdoor Termination Kit ( 1-Phase / 3 Phase ) 171 C ) 33 Kv Indoor Termination Kit ( Single Phase ) 172 D ) 33 Kv Outdoor Termination Kit ( Three Phase ) 173 E ) 33 Kv Indoor Termination Kit ( Three Phase ) 174 F ) 33 Kv Outdoor Termination Kit ( Single Phase ) 175 G ) 66 Kv Indoor Termination Kit ( Single Phase ) 176 H ) 66 Kv Outdoor Termination Kit ( Single Phase ) 177 Improvement Of Earthing System In Control Room By Way Of Replacement Of Earthing Risers From Earthing Point To Panel / Checking Of All Welding Points / Re-Welding Of Lose Connection, Laying Of Fresh / Additional Earth-Mat Strip To Improve The Existing Earthing System ( Complete One Panel Set ) 178 Checking Of Ir Values 179 De-Watering Of Receiving Station To Avoid Water Logging. 180 Repairing Of Electrical Circuits For Improvement Of Control Room Immunination, Power Points Etc ( Complete Job ) 181 Installation, Testing, Commissiing For Replacement Of Aux. Transformer At Receiving Station 182 On Site Repairing Of Aux Transformer For Missing Phase, Lt Strip, Lt Bush Rod, Lt Bush Cup, Ht Bush Rod Etc ( Complete Job ) 183 Transport Charges For Carriage Of T&P, Men & Material On Urgent Basis During Power Breakdown And Restoration Of System. ( Auto Carrier ) Aditional 1Km @ 90 / Per Km 184 Replacement Of Out Door Yard Lights Including Wiring System And Fixing Oflamps On Fixtures. 185 Marking Of EquipmentS, Sign Boards By Way Of Painting / Fixing Of Pvc Plates For Demarcation Of Different Equipment To Avoid Mishandling. 186 Replacement / Repair / Fixing Of Ceiling Fans At Receiving Station. 187 Replacement / Repair / Fixing Of Cooling Fans On Radiators Of Power Transformer To Avoid Heating. 188 Flash In 66Kv, 33 Kv & 11 Kv Panels Due To Overloading Moisture, Cleaning Of Carbonized Panel By Petrol / Cotton Cloth, Replacement Of Damaged / Worn-Out Lugs, Post Insulator, Bakelite Sheet, Arcing Chamber Panel Heaters Etc. 189 Repair Of Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Areas 2.5 Sqm Meters And Under Including Cutting The Patch In Proper Shape And Preparing And Plastering The Surface Of The Walls Complete Incl. Disposal Of Rubbish To The Dumping Ground Within 50 M Leada ) With Cement Mortar 1:4 ( 1 Cement : 4 Fine / Coarse Sand ) 190 Cutting Of Large Tree Branches Falling Over 66 / 33 Lines And Coming Into The Corridor To Avoid Damages / Faults / Conductor Snapping. 191 Cleaning Of Cable Duct, Removing Of Duct Covers And Placing Back After Cleaning The Duct Including Disposal Of Rubbish Up To 50 Mtr Lead 192 Replacing Sand Store Slabs In Roofing, Laid Incement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including Necessary Repairs And Cement Painting With Same Mortar Complete, Including Disposal Of Rubbish To Dumping Ground Within 50 Meters Of Lead 193 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chow Khats, Holdfast Etc. Complete And Stacking With 50 Mtr Lead 194 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel T-Sections, Joints Mitred And Welded, Including Fixing Of Necessary But Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer ( Cc 1:3:6 ) 195 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Mtr 196 Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) 62 Mm Thick 197 Roof Top Treatment To Prevent Water Leakage Of Control Room 198 Repairing Of Receiving Station Mesh Fencing / Chain Link Mesh Fencing Height Upto 8Ft 199 Watering Of Earth Pits 200 Cleaning Of Acdc, Dbdc Board, Rtcc, Charger, Battery Bank, Solar Batteries, Other Alike Small Equipments ( Complete Job ) 201 Cleaning Of 66 / 33 Kv Crp Using Vacuum Cleaner From Inside With Proper Care, From Outside With Thinner / Varnish And Making 66 / 33 Kv Crp Vermic Proof. 202 Cleaning Of 11 Kv Panel Using Vacuum Cleaner From Inside With Proper Care, From Outside With Thinner / Varnish And Making It Vermic Proof To Avoid Rodent Faults. 203 Erection Of Channel Cross Arm Of Size 100X50x 6Mm , 10 Feet Long And Above Including Fixing Of Ms Flat Iron Clamps With Required Size Of Bolts Including Punching Of Bolts Complete 204 Erection Of Channel Cross Arm Of Size 100X50x 6Mm Up To 09 Feet Long Including Fixing Of Ms Flat Clamps With Required Size Of Bolts Including Punching Of Bolts Complete 205 Erection Of Angle Iron Braces Of Size 65X65x6 Mm, Fixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Cross Section Typeabove Up To 14Longcomplete 206 Erection Of Angle Iron Braces Of Size 65X65x6 Mm Along With Belts Of Same Size , Fixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Cross Section Type 6 And Above Upto 10Longcomplete 207 Erection Of Angle Iron Belts Of Size 50X50x 6 Mm Along With Belts Of Same Size , Fixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Cross Section Type Upto 10 Long 208 Erection Of Angle Ironof Size 65X65x6 Mmfixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Crossection Typeabove11 Long Complete For Guardnetting. 209 Flat Iron Ties 50X6 Mm Size 1 Feet Long Along With Fixing With Cross Arms 210 Erection Of 66 Kv Disc Insulator ( Polymer Type ) With Tension Fittings Including Punching Of Locking Pinscomplete 211 Erection Of 33 Kv Disc Insulator ( Polymer Type ) With Tension Fittings Including Punching Of Locking Pinscomplete 212 Erection Of 66 Kv Pin Insulator With Pins3 Nos On Top Of Cross Arm Including Fixing Of Ms Flat Ties To Rest It On , Punching Of Base Bolt / Locking Pin Complete 213 Erection Of 33 Kv Pin Insulator With Pins3 Nos On Top Of Cross Arm Including Fixing Of Ms Flat Ties To Rest It On , Punching Of Base Bolt / Locking Pin Complete 214 Erection Of Guy Rodincluding Digging Of Pit , Disposal Of Excavated Soil , Refilling Of Excavated Pits In Layers Of Stone Boulders And Fine Soil Including Fixing , Adjusting Properly Turn Buckle, Anchor Plate And Staining Screw Complete 215 Carriage At Site , Un-Bundling , Laying And Stringing Of Acsr Dog Conductor Including Making Of Small Bundles Of Conductor As Per Site Requirement, Cutting In Required Span Lengths Complete ( As Per Rec Standard ) 216 Erection Of Anti Climbing Devices At St Pole Along With Fixing / Cutting / Bending Of Barbed Wire, Fixing With Clamps 217 Erection Of Danger Plates 218 Route / Temp Path Clearance By Way Of Cleaning Bushes And Vegetation & Making Temp. Pathcutting & Filling For Carriage Of Line Material ( 400 Mx1mx0.2M ) = 80 Cum 219 Watch And Ward Of The Material And T&P Round The Clock I.E. 3 Shifts, Rate Of 1 Lab For 1 Shift 220 Route Clearance For Corridor Of 5 M 221 Installation, Testing And Commissioning Of 11Kv Panel Board With Vcb Incomer ( One No. ) 222 Installation, Testing And Commissioning Of 11Kv Panel Board With Vcb Outgoing ( One No. ) 223 Setting Of Stubs With Templates After Positioning And Leveling Of Templates Excluding Cost Of Foundations 224 Handling And Fabrication Of Material In Divisional Store, Fabrication Of Angle Iron Braces / Belts / Guard Netting Angles, Fencing Posts Etc From Angle Iron Of Sizes 225 Fabrication Of Guy Rods Complete Including Turn Buckle, Staining Screw, Anchor Plate, Thereading Of Guys And Staining Screw 226 Fabrication Of Channel Cross Arms Of Sorts From Ms Channel Of Sizes , Making Holes As Per Requirement, Punching Of Members And Numbering On Each Member, Grinding Of Sharp Edges And Uneven Surface Of Memebers And Painting Of Members With Red Oxide Paint. 227 Fabrication Of Ties, Clampsfrom Ms Flat ( Suitable For 9 Mts, 11Mts, 13Mts & 16 Mts Poles ) 228 Fabrication Of Earthing Plates , Cable Duct Coversfrom Ms Plate As Per Rec Drawings 229 Fabrication Of Earthing Spikes From Ms Tor Steel Of Sorts As Per Rec Drawings 230 Fabrication Of St Poles By Way Of Drilling Of Extra Holes 231 Fabrication Of Foundation Boltsfrom Ms Tor Steel Of Sorts Including Threading As Per Rec Drawings 232 Fabrication Of Earthing Pipe From Gi Pipe And Welding Of Earthing Plateas Per Rec Drawings 233 Fabrication Of Column Structures, Beam Structure, Isolator Structures, La , Ct, Pt And Pi Structures As Per Rec Drawings 234 Shifting Of Channel / Angle / Flat Iron At And Average Distance Of 50Mtr From Unloading Site To Site Of Stacking And Stacked Properly. 235 Shifting Of Channel / Angle / Flat Iron / Fabricated Material At And Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking . 236 Unloading Of Pcc Poles 9 / 8 Mts . 237 Unloading Of Pcc Poles 11 Mts . 238 Unloading Of Pcc Poles 13 Mts . 239 Dragging / Shifting Of Pcc / St Pole At And Average Istance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satacking 240 Shifting Of Old / New Acsr Conductor At And Average Distance Of 50Mtr For Unloading Site To Site Of Stacking And Stacked Properlyand Also For Making Space For Other Store Material And Its Stacking .. 241 Unloading Of 11Kv Vcb Pannels ( 1+3 ) 242 Unloading Of 11Kv Vcb Pannels ( 1+4 ) . 243 Unloading Of 11Kv Vcb Pannels ( 1+5 ) . 244 Unloading Of 11Kv Vcb Pannels Ok / Damaged ( 1No ) . 245 Unloading Ofac Board / Dc Board / Battery Bank / Battery Charger 246 Unloading Of 33 / 66 Kv Vcb / C&R Pannel . 247 Shifting / Draggingof 11 / 33 / 66Kv Panel At An Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking Also For Making Space For Other Store Material And Its Stacking . 248 Unloading Of Xlpe Cable 120 / 185 Mm² . 249 Unloading Of Xlpe Cable 240 / 300 Mm² . 250 Unloading Of Xlpe Cable 400 / 630 Mm² . 251 Shifting Of Xlpe Cable All Sizes At An Average Distance Of 50Mtr From Unloading Site To Site Of Stacking And Stacked Properly Also For Making Space For Other Store Material And Its Stacking ... 252 Unloading Of 66 / 33 / 11 Kv Cable Kits Of Different Sizes 253 Shifting Of 66 / 33 / 11 Cable Kits Of All Sizes At An Average Distance Of 50Mtr From Unloading Site To Site Of Stacking And Stacked Properly Also For Making Space For Other Store Material And Its Stacking ... 254 Unloading Of Guy / Gi Wire / Barbed Wire Including Carriage Towards Stacking Site And Stacked Porperly. 255 Unloading Of 11Kv New / Damaged Distributiontransformer. 256 Dragging Of 11Kv Transformer At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satacking 257 Unloading Oftransformer Oil Barrels. 258 Dragging Oftransformer Oil Old / New Barrel At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satacking Also For Making Space For Other Store Material And Its Stacking .. 259 Unloading Ofms Angle, Ms Channel, Ms Flate , Tar Steel 260 Unloading Of Hardware Items Such As Nuts And Bolts , Clamps Of Sorts, Washers, Welding Rods, Old Sarees, Chain Link Mesh, Pipe Etc . 261 Shifting Ofhardware Items Such As Nuts And Bolts , Clamps Of Sorts, Washers, Welding Rods, Old Sarees, Chain Link Mesh, Pipe Etc At An Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking . 262 Unloading Of 33 / 11 Kv Disc Insulators. 263 Unloading Of 33 Kv Disc Fittings 264 Shiftingof 33 / 11Kv Disc Insulator At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satackingalso For Making Space For Other Store Material And Its Stacking .. . 265 Unloading Of 33 / 11 Kv Pin Insulators / Guy Insulator / G.I Pin. 266 Shiftingof 33 / 11Kv Pin Insulator / Guy / G.I Pinsat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking. 267 Unloading Of Cement. 268 Shiftingofcement / Cement Block At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking ... 269 Unloading Of 33 Kv Ct / Ptunit . 270 Shifting Of 33 Kv Ct / Pt At An Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking . 271 Unloading Of 11 Kv Ct / Ptunit Includingcarriage Towards Stacking Site And Stacked Porperly. 272 Shiftingof 11 Kv Ct / Ptat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 273 Unloading Of 33 Kv Isolators. 274 Shiftingof 33Kv Issolatorsat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satackingand Also For Making Space For Other Store Material And Its Stacking . . 275 Unloading Of 33 / 66 Kv Las. 276 Shiftingof 33 / 66Kv Lasat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking . 277 Unloading Of 11 Kv Las / Go / Hg / Issolator . 278 Shiftingof 11 Kv Las / Go / Hg / Issolator At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 279 Unloading Of Pvc Cable / Control Cable Of Different Sizeincludingcarriage Towards Stacking Site And Stacked Porperly. 280 Unloading Of Al Paint / Red Oxide Paint / Black Paintincludingcarriage Towards Stacking Site And Stacked Porperly. 281 Unloading Of 66Kvct / Pt / Isolator . 282 Shiftingof 66 Kv Ct / Pt / Isolator At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 283 Unloading Of T&P Items Like Drilling Machine, Chainpully , Pully Lifting Machine , Hand Drill Machine, Al Ladder, Welding Set, Tool Kit, Crimping Tooletc 284 Dismantling Of Old 11Kv Isolator Including Allied Equipments 285 Installation Of 11Kv Isolators 286 Shiftingof T&P / Testing / Safetyequipments At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 287 Unloading Of Filter Plant Heavy Duty 288 Shiftingof Filter Plantat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking . 289 Loading Of Pcc Poles 9 / 8 Mtr 290 Loading Of Pcc Poles 11 Mtr 291 Loading Of Pcc Poles 13 Mtr 292 Loading Of Cement 293 Loading Of 11 Kv Vcb 1+3 Pannels 294 Loading Of 11 Kv Vcb 1+4 Pannels 295 Loading Of 11 Kv Vcb 1+5 Pannels 296 Loading Of 11 Kv Vcb 1 Pannel Ok / Damage 297 Loading Of Ac Board / Dc Board / Battery Charger / Battery Bank 298 Loading Of 33Kv Vcb 299 Loading Of 33Kv C&R Pannels 300 Loading Of Xlpe Cable 120 / 185 Mm² 301 Loading Of Xlpe Cable 240 / 300Mm² 302 Loading Of Xlpe Cable 400 / 630 Mm² 303 Loading Of Cable Kits Of Different Sizes 304 Loading Of Guy / Gi Wire / Barber Wire 305 Loading Of 11 Kv Distributiontransformer 306 Loading Of Transformer Oil Barrels 307 Loading Of Ms Angle Iron Braces, Ms Channel Cross Arms, Guy Rod, Earthing Spikes, Ms Flate 308 Loading Of Hardware Items Such As Nuts And Bolts, Clamps Of Sorts, Washers, Welding Rods, Old Sarees, Chain Link Mesh, Pipe 309 Loading Of 33 / 11Kv Disc Insulator 310 Loading Of 33 Kv Disc Fitting 311 Loading Of 33 / 11 Kv Pin Insulator / Guy Insulator / G.I Pin 312 Loading Of 33 Kv Isolator 313 Loading Of 33 Kv La 314 Loading Of 11Kv Isolators 315 Loading Of Pvc Cable / Control Cable Of Different Size Includingcarriage From Stacked Site. 316 Loading Ofal Paint / Red Oxide Paint / Black Paint 317 Loading Of66kvct / Pt / Isolator 318 Loading Of66kvc&R Pannel 319 Loading Of66kv Vcb Breaker Sf6 320 Loading Of66kv La 321 Loading Offilter Plant Heavy Duty 322 Carriageof Fabrication Column Structures, Beam Structure, Isolator Structures, La , Ct, Pt And Pi Structures Etc Towards Stacking Site And Stacked Properly 323 Loading Offabrication Column Structures, Beam Structure, Isolator Structures, La , Ct, Pt And Pi Structures Etcincludingcarriage From Stacked Site. 324 Loading Of 33 Kv Ct / Pt Units 325 Loading Of 11 Kv Ct / Pt Units 326 Loading Of T&P Items Like Drilling Machine, Chainpully , Pully Lifting Machine , Hand Drill Machine, Al Ladder, Welding Set, Tool Kit, Crimping Tooletc Units 327 Loading Of Testing Equipments Like Meggar, Earth Resitivitytester , Oil Testing Machine, Search Light, Turn Ratio Meter , Multimeter Etc Units 328 Loading Of Safetyequipments Like Safety Belts, Safety Shoes, Fire Extinguisher, Hand Gloves, Yard Lights , Led Bulbs , Rubber Mat , Etcunits 329 Shifting Of Allied Materials For Making Space For Porper Stacking Of Material 330 Carriageof Fabrication Material From Fabrication Site Towardsstacking Site And Proper Stacking Of Material. 331 Repair Of Store Shed By Way Of Replacement Of Damaged Cgi Sheets, Repair Of Cgi Sheets By Way Of Welding, Replacememt Of Hooks, Nuts And Bolts, Tightening Of Nuts Bolts And Hooks And Welding . 332 Collection Andcarriage Of T&P Items To Working Site And Back Crriage Of T&P After Job 333 Replacement Of Damaged Glass Panes 334 Replacement Of Damaged 66 / 33Kv PiS 335 Checking / Measuring / Inspection / Meggering Ofxlpe Cable / Control Cable By Way Of Unreal And After Work Agian Rereelingon Drum 336 Checking / Measuring / Inspection Ofacsr Conductorby Way Of Unreal And After Work Agian Re-Reelingon Drum 337 Complete Testing / Inspection Of Pannels Including Relay Testing , Interconnection, Charging Polarity Etc During Issue / Receipt / Verification. 338 Prototype Erection Of Gantry / Beam / Ct / Pt / Isolator Sturcture 339 Charges For Providing Highly Skilled Electrician / Fitter / Welder / Mason / Painter 340 Charges For Providingskilled Electrician / Fitter / Welder / Mason / Painter 341 Charges For Providingunskilled Labour

Key Value

Document Fees
INR 1000 /-
EMD
INR 100000.0 /-
Tender Value
INR 50 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail