Military Engineer Services-MES has published Special Repair To Renewal/Replacement Of Earthing Pit, Lightening Arrester, Sewage Pump, Submersible Pump, Mono Block Pump And Allied Services At Air Force Station Kalaikunda Under Ge (Af) Kalaikunda. Submission Date for this Tender is 08-09-2022. Electrification Work Tenders in kalaikunda West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

33511652
Corrigendum : Special Repair To Renewal/Replacement Of Earthing Pit, Lightening Arrester, Sewage Pump, Submersible Pump, Mono Block Pump And Allied Services At Air Force Station Kalaikunda Under Ge (Af) Kalaikunda
Open Tender
Indian
West Bengal
kalaikunda
08-09-2022

Tender Details

Special Repair To Renewal/Replacement Of Earthing Pit, Lightening Arrester, Sewage Pump, Submersible Pump, Mono Block Pump And Allied Services At Air Force Station Kalaikunda Under Ge (Af) Kalaikunda

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 73600.0 /-
Tender Value
INR 36.80 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR TO RENEWAL/REPLACEMENT OF EARTHING PIT,LIGHTENING ARRESTER ,SEWAGE PUMP ,SUBMERSIBLE PUMP,MONO BLOCK PUMP AND ALLIED SERVICES AT AIR FORCE STATION KALAIKUNDA UNDER GE (AF) KALAIKUNDA
Sl. No. Item Description
1Taking down old unserviceable GI/Copper earth plateincluding all fitting and fixture from soft and hard soilwith and including demolition of exiisting earthing pit and making good disturbed atany location as directed byEngineer -in- charge.
2Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (3 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately.
3Note : (i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 3 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance. (ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate. (iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. (v) Contractor has to submit test report of earthing after completing the earthing. (vi) Bentonite clay should be Conf to IS 6186: 1986.(NOTE: (vii)The cost ofCopper strip of size 20X3 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. (viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (viiii) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (ix) Cost includes removal of excavated soil upto a distance of 100 mtrs.
4Taking out old unserviceable GI/aluminium/copper earth strip or for relaying/ refixing the same existing strip by providing procline insulatorsof any size and type in any height and any location as directed by Engineer In charge.
5Supply and fixing copper strip of size 20 x 3mm as earth continuity conductor or main earthing lead fixed on "V" typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip)
6Supply and fixing copper strip of size 32 x 6mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator 10 BM heavy duty ( ceramic bus bar supportinsulator off whitecolour of min size of 36 mm width x 60 mm length with 36 mmwidth bus bar mounting base) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer all as specified and directed by Engr in Charge.Note : Insulators shallbe provided on every 50 cm. (Minimum 2 x insulators shall be provided in every 1 x metre of strip deemed to be included in quoated rates)
7Supply and fixing copper strip of size 50 x6 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulators, 10 BM heavy duty ( ceramic bus bar supportinsulator off whitecolour of min size of(ceramic bus bar supportinsulator off whitecolour of min size of 50 mm width x 70 mm length with 50 mmwidth bus bar mounting base) saddleto wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for earthing etc. as required 50x 6 mm copper strip brazingto each joints and connected with by providingbrass nut bolts and washer all as specified and directed by Engr in Charge. (Minimum 2 x insulators shall be provided in every 1 x metre of strip deemed to be included in quoated rates)
8Supply and fixing aluminium strip of size 25 x 3 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulators, 4 BM,heavy duty(ceramic bus bar supportinsulator off whitecolour ofsuitable size for mounting strip of 20 mm wide x 3 min thick)) saddleto wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as requiredand connected with by providingbrass nut bolts and washer all as specified and directed by Engr in Charge.Note : Insulators shall be provided on every 50 centimeter. (Minimum 2 x insulators shall be provided in every 1 x metre of strip deemed to be included in quoated rates)
9Material & labour for Refixing of existing serviceable copper / aluminium / GI striptaking outout under BOQ serial item No. 3 above here in before , on top of "V" typeprocelain insulator ( ceramic bus bar supportinsulator off whitecolour ofsuitable sizefor mounting of insulator) fixing strip on insulator with brass nuts and bolt ,screws, aluminium cleats etc.( Procelain insulator if replaced shall be measured separetly) duly straightened properlyand fixingin neat dressed manner as directed by Engineer in charge. Note: (i) Proclelain insulator shall bemeasured and paid seperately under relevant item
10Material & labour for porcelin insulater 10 BM heavy duty (ceramic bus bar supportinsulator off whitecolour of min size of 50 mm width x 70 mm length with 50 mmwidth bus bar mounting base for fixing strip of widthabove 32 mm to 50 mm fixing on wall for supporting the copper stripincludingsuitable size brassnuts andbolts, washers,drilling hole on wall to fix porcelain insulator , fixing insulator by providing steel screws etc complete all as specified and directed by Engineer-in-charge.( Note : Cost of brass nut bolt and washer and steel screw for fixing insulator isdeemed to be included in unit rate of item).
11Material & labour for porcelin insulater4 BM heavy duty (ceramic bus bar supportinsulator off whitecolour of min size of 36 mm width x 60 mm length with 36 mmwidth bus bar mounting base for fixing strip of width up to 32 mmfixing on wall for supporting the copper strip of size 20 x 3 mm and up to 32 mm width includingsuitable size brassnuts andbolts, washers,drilling hole on wall to fix porcelain insulator , fixing insulator by providing steel screws etc complete all as specified and directed by Engineer-in-charge. ( Note : Cost of brass nut bolt and washer and steel screw for fixing insulator isdeemed to be included in unit rate of item).
12Material & labour for carrying out brazing workof copper earth strip joints,after removing the nut bolt, scraping and cleaning the strip surface all as specified by Engr-in-charge. Note : Size of earth strip is 20 x 3 mm to 25 x 3.15 mm
13Supply & Fixing for thermoplastic(polycarbonate) junction box for test point without terminal block of dimension 130 x 180 x 77 mm IP 66 halogen free and weather proof including four hexagonal anticorrosive screws for out door installation including taking down unserviceable one complete all as specified and directed by Engineer-in-charge Make : Hensel- Cat part No. KF 0600 H or as equivalent in Sintex.
14M&L in repair for Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed incl 3 Nos 8mm dia 25mm long hexagonal head screws for fixing strips to test point including necessary fixing arrangement to fix test point terminal block in junction box with andincluding taking down unserviceable one complete all as specified and directed.
15Supply & Fixing hexagonal head brass nut bolt and washer (Bolt size not less than30 mm long from under side of head to endand not less than 6 mm dia) as specified and directed by Engr-in -charge.
16Supply & Fixing hexagonal head brass nut bolt and washer (Bolt size not less than50 mm long from under side of head to endand not less than 7 mm dia) as specified and directed by Engr-in -charge.
17Taking down old broken and damaged earth pit chamber and M & L for construction ofnew earth pit chamber of brick workwith plaster in outer and inner surface , copping of of PCC 1:2:4 Type A-1. Earth pit shall be ofsize 600 x 600 x600 mm embedded in ground below GL 150 mm withopenable cover made up of MS sheetofminimum 2.8 mm thicknessfixed in angle iron frameand handle including GI funnel and wire mesh , including paintingthe complete pit withtwo coat of synthetic enamel paint as per colour codeapproved by EIC and all as specified and directed
18Material & labour GItubing medium grade 40mm borefor fixing the air termination rods on top of pipe with necessary clamping arrangement and other fitting required.The GI pipe shall beembedded in PCC bed blocks andtied with Stainless steel wire rope for free stand alone of pipe compete all as directed. Note:- PCC bed blocks shall be measured and paid saperately under relevant item of BOQ.
19Materials and Labour for plain cement concrete (1:3:6) Type C-2 using 40 mm graded aggregate in foundations, filling and mass concrete with andincluding demolition of existingcomplete all as specified and directed.
20Materials and Labour for plain cement concrete (1:3:6) type C1 using 20 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary from work with andincluding demolition of existingcomplete all as specified and directed.
21Materials and Labour for brick work with Sub Class ‘B’ bricks straight or curved on plan exceeding 6M mean radius built in cement mortar (1:4), complete all as specified and directed.
22Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:4) on fair faces of brick work or concrete surface in walls,complete all as specified and directed.
23M & L in repairAir termination, single pointed, aluminium rod 12mm dia and 300mm long complete fixed on wall/roof including fitting and fixingarrangement all as specified and directed..
24M & L in repair Air termination, single pointed, copper rod 12mm dia and 300 mm long complete fixed on wall/roof including fittings andfixing arrangement all as specified and directed..
25Supply and fixing stainless steel wire rope PVC insulatedof minimum thickness 6 mm for holding GI pipe of 50/ 40 mm dia to stand straight vertical mounted with lightening arrester spike with and including taking out unserviceablecomplete all specified and directed by Engineer -in-charge
26Supply and fixing stainless steel wire rope clamp grip for rope clamping "U" with nut bolts washer etc all as specified and directed by Engineer -in-charge
27Supply and laying of UPVCpipe of pressure rating 10 kgf/sq.cm of size 25 mm dia for protection of copper earth strips with and including taking out unserviceable completeallas specified and directed
28Material & labourin repairsPVC insulated, Single coreflexible copper conductorcable, 1100 Volt, Conf to IS 694, ISI markedof size 70 Sqmm including fixing it ontower of 40 mtr heightby providing GI stripclamp and also by using Heavy duty PVC tyefrom LA at top of tower to earthing pit on ground, and any other locations like on wall or laying on floor by providing saddles, including connecting terminals by providingcopper lugs, brass nut and bolt with washer of suitable size as per site requirement to connect the cable including taking down unserviceabledeterioted aluminiumcomplete all as specified and directed by Engineer in Charge.
29Supply and fixing Brass Copper lightening arrester 9.2 mm diameter and 915 mm in length with 5 spikes and base plate 8.5 x 8.5 cm for building protection coverage of 45 degress from the top point 1.85 m all as specified and directed by Engineer in Charge.
30Material & labour for fabrication of display board for earth pit nos, lacation and periodical test results for power circuit earthing, machinary earthing ,lighteningconductor earthing, made of MS sheet 3.0 mm thick sheet, rectangular welding on angle iron of 25 x25 x4 mm of 600 mm height from ground level 30 cmincluding fixing in PCC 1:2:4 with 20 cm X 20 cm X 20 cm (below ground level) grade aggregate foundation to be carried outat different location technical area/domestic area . Dimention of board shall be 30 cm X 25 cm. or any other dimention not more than 0.075 sq mtr of MS BoardThe instruction shall be written black painted board in white letters not less than 2 " size for all type of boards complete all as specified and dierected by the Engineer -in-charge including taking down unsv one. Note : (a)All necessary MS sheet, aluminium screws and PCC works minimum M15 grade etc are deemed to be inclusive the rate quoted by the contractor (b) The matter to be write on board shall becollected from Engineer-in-charge..
31M&L for Advanceencapsulated compound based Marconite compoundearthing maintenance free , with copper electrode of 88 mm dia (strip in pipe technology upgradedearthing system conforming IS 3043. The outer copper pipe shall be of 88 mm dia or manufacturer instruction and inner copper strip shall be of 25 x 3 mm respectively of3 mtrs long withterminal size 50 x 6 mm. The annular space between the pipe and strip to be filled up with Compactfill (CF) (Crystalline Conductive) mixture. The job includesexcavation of pit in any type of hard dense soil/ disinterigated rocky strataof size 1000 mm x 1000 mm x 3050 mm depth and taking out all excavated soil, lowering and placing copper electrode in centre of pit andfilling ofback fill marconite compoundhaving excellent moisture retaining capacity in sourrounding of electrode in300 mm dia all around the electrode( Min 4 bags of 25 Kg each ofMarconite back fill compound per pit per unit to be fill or more quantity of BFC if required to achive less than one ohms). The remaining portion of earth pit to be filled with agriculture soil / back cotton soil free from stones etcto be bring from out side defence land . The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:2:4) typeB1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. NOTE: 1) The quantity of BFC indicated above is generally for normal/good soils.In case the soil resistivity is high , the quantity of BFC should be increased & cost of the same is deemed to be inclusive in the quoted rates. 2). If the desired earth resistance not obtained the earthing shall be re-done by contractor without any extra cost to Govt . 3). Removal of excavated soil and filling of agriculture soil brought from out side defence land shall be included in the overall rate quoted.
32Make : Copper electrode : True Power Earthing Pvt Ltd. Model No. 88MTPPC ( 3 MTR Long, 88 mm dia) Product code CE -E-003 or equivelant make. Back fill compound : Marconite : Product of Carbon International Ltd. UK."Marconite"electrically conductive aggregate, to be used as backfillto enhance the effect of earth electrodeand suitable for rock and all type of ground conditionhaving low resistivityup to 0.001 Ohm meter, inert PH material, Corrosion free green product in bag of 25 Kg each) Note :-(i) Design of earth electrode should be of Strip -in-pipetechnology . (ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement. (iii) The earth electrode shall be CPRI approved. (iv) Contarctor has to fill pure back fill compound all around the earth electrodein 300 mm bore up to full depth of bore. (v) Copper strip will be laid below 20 cm from ground level and connecting the test point through plinth protection using HDPE pipe for protection, necessary cost of repair to plinth protection and brazing and welding deemed to be included in the item. (vi) Contarctor shall submit the test report of earthing after completing the work of earthing. (vii) Contractor shall remove and disposed off the soil excavated from boring and clear the site before completion of work. (viii) Contractor has to submit the test certificate of electrode and back fill compound before claiming the payment.
33Excavation in trenches in soft/loose or any type ofsoil n. exc 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out all excavated materials and forming bottom surface to required level gradientfor laying of water tubing complete all as specified and as directed.
34Returning filling in soft/loose soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
35Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all asspecified and directed.
36Takingupold galvanised steel water tubingmedium grade for thefollowing bore laidin trenches including all fittingcleaning of serviceable pipe and segregating for re-use and removing unserviceable pipes from site of work complete all as specified and directed by Engr-in-Charge.
37(a) 150 mm bore GI pipe complete
38(b) 100 mm bore GI pipe complete
39Takingup or down of old galvanised steel water tubingmedium grade in walls, floors or ceilings etc including all fittingcleaning of serviceable pipe and segregating for re-use and removing unserviceable pipes from site of work complete all as specified and directed by Engr-in-Charge.
40(a) 150 mm bore GI pipe complete
41(b) 100 mm bore GI pipe complete
42(c ) 65 mm GI pipe complete
43(d)50 mm GI pipe complete
44Supply and laying galvanised steel water tubingmedium grade as per IS-1239 (Part-1)2004 including all fittings conforming to IS 1239 (Part-2): 2011laid in trenches innew or old alignment complete with GI pipe clamp all as specified and as directed by Engr-in-Charge. Make: TATA/JINDAL or equivalent make as catered in PS
45(a) 150 mm bore GI pipe complete
46(b) 100 mm bore GI pipe complete
47Supply and laying galvanised steel water tubing medium grade as per IS-1239 (Part-1) 2004 including all fittings conforming to IS 1239 (Part-2): 2011and fixed complete to walls and ceilings or laid in floors innew or old alignment complete all as specified and as directed by Engr-in-Charge. Make: TATA/JINDAL or equivalent make as catered in PS
48(a) 150 mm bore GI pipe complete
49(b) 100 mm bore GI pipe complete
50(c ) 65 mm GI pipe complete
51(d)50 mm GI pipe complete
52S & F GI flange of 150mm bore pipe duly threaded and holed including leather gasket MS bolts, nuts, washer including necessarry repair to make it functional andtaking down old flange complet all as specified and as directed by Engr-in-Charge.
53S & F GI flange of 100mm bore pipe duly threaded and holed including leather gasket MS bolts, nuts, washer including necessarry repair to make it functional andtaking down old flange complet all as specified and as directed by Engr-in-Charge.
54Supply, installation, testing and commissioning of Sewage submersible(Non clogging) / Dewatering Pump of capacity 7.5 KW/ 10 HP, 3 Phase, 415 Vcomplete all as per Make :Kirloskar, Model : 7500 CW or equivalent in KSB/Crompton with and including dismantling existing pump motor set completeall as specified and as directed by Engr-in-Charge. (Note : Old unservieable pump-motor set shallbe deposited in MES Store Yard and RV submitted along with FB.)
55S & Fsubmersible pumpstarter in open execution suitable for 415V, 3ph,7.5KW, upto 10 HP with SPP feature, with relay range 14-22 amps, for submersible pump setcomplete all as per Make : C & S, Model : BE1-SPSDDX254 321X or equivalent in L&T/Siemens/Crompton including taking out old unserviceable onecomplete all as specified and as directed by Engr-in-Charge.
56S & F in repairs submersible cable flat PVC insulation of type C and having PVC sheath of type ST2, flexible conductor, FR-LSH, 3 core of size 6 sqmm complete all as specified and as directed.
57S & F for steer wire rope (SWR) of 10 sqmm PVC coated with "U" clamps for fixing pump with support beam in installation all as specified and as directed by Engr-in-Charge. Make : Usha Martin or equivalent make
58M & L in repairs for rising stem type sluice valves of nominal pressure (PN 1.6) as per IS 14846: 2000, nominal size 100 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.
59S & F flanged reflux valve (non-return) of single door, swing check type nominal pressure (PN 1.6) of preferred materials as per IS 5312 (Part 1): 2004, nominal size 100 mm complete all as specified and as directed.
60S & F in repair for Cast Iron Air valve of stainless steel float, PN-1.6 flanged type of size 100 mm dia bore as per IS :14845 complete all as specified and as directed by Engr-in-Charge.
61Supply, installation, testing and commissioning of monoblock pump set of capacity 3.73 KW/ 05 HP, 3 phase, speed 3000rpm, Dicharge range not less than 7 LPS ,415 V of size 65 x 50mm including testingcomplete all as per Make Kirloskar KDS-538+ or equivalent in KSB/Crompton complete and including dismantling existing pump set completeall as specified and as directed by Engr-in-Charge.. (Note : Old unservieable monoblock pump set shallbe deposited in MES Store Yard and RV submitted along with FB.)
62S & Fsubmersible pumpstarter in open execution suitable for 415V, 3ph,3.7KW, upto 5 HP with SPP feature, with relay range 7-10 amps, for submersible pump setcomplete all as per Make : C & S, Model : BE1-SPSDDX204 314 or equivalent in L&T/Siemens including taking out old unserviceable onecomplete all as specified and as directed by Engr-in-Charge.
63S & F in repairs submersible cable flat PVC insulation of type C and having PVC sheath of type ST2, flexible conductor, FR-LSH, 3 core of size 4 sqmm complete all as specified and as directed.
64S & F for Gun Metal foot valve of size 65mm bore, threaded type for fixing in centrifugal pump suction pipe end side all as specified and as directed by Engr-in-Charge.
65S & F Bronze horizontal non return valve of size 50mm bore, threaded type, in centrifugal pump delivery line all as specified and as directed by Engr-in-Charge. Make : Zoloto/Kirloskar/Venus/Kartar
66S & F Bronze Gate Valve, screwed type of size 50 mm all as specified and as directed by Engr-in-Charge. Make : Zoloto/Kirloskar/Venus/Kartar
67Supply, installation, testing and commissioning of suction sweeper vaccum cleaning set for swimming pool of 03 HP motor mounted on Stainless Steel trolly, Starter Kit including all mountings, 02 core wire lead 20RM, fittings with Stainless Steel Suction head 24"", Aluminum handle 4.8 RM, hose pipe 30MTR, Algae brush 10"", Wall Brush 10"", Test kit CL & PH and Deep leaf net bag including taking out old u/s completeall as specified and as directed by Engineer-in-Charge. (Note : Old U/S SSV cleaning setset to be deposited in MES Store Yard.)
68Supply, installation, testing and commissioning of Trolly mounted, Self priming Engine driven pump of capacity 10 HP, 1500 RMP, Discharge 36-12 LPS, Head (12 + 26 MTR), suction & delivery size (100mm x 100mm), Air cool, hand operated with Portable Trolly having accessories as base frame, coupling, coupling guard, foundation bolts and nuts with fuel tank without battery and Trolly MS fabricated having toe hook for dewatering/ sewage/ Waste water purposeincluding dismantling of existing unserviceable one all as specified and as directed by Engr-in-Charge. Make : Kirloskar or equivalent make (Note : Old u/s pump-motor set to be deposited in MES Store Yard.)
69S & F Rolled mild steel in purlins, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats for foundation work of pumpset etc. conforming to Fe 410-W(Gde-E- 250) quality-A all as specified and as directed by Engr-in-charge.