Repairs To Internal And External Electrification Including Apfc At Vishwa Vihar Under Ge Af , marathahalli-Karnataka

Military Engineer Services-MES has published Repairs To Internal And External Electrification Including Apfc At Vishwa Vihar Under Ge Af . Submission Date for this Tender is 08-09-2022. Electrification Work Tenders in marathahalli Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

33507821
Corrigendum : Repairs To Internal And External Electrification Including Apfc At Vishwa Vihar Under Ge Af
Open Tender
Indian
Karnataka
marathahalli
08-09-2022

Tender Details

Repairs To Internal And External Electrification Including Apfc At Vishwa Vihar Under Ge Af

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Aug-2022 OTHER CORRIGENDUM2 Other 01-09-2022
2 22-Aug-2022 BOQ CORRIGENDUM_1 BOQ 01-09-2022
3 01-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 44000.0 /-
Tender Value
INR 22 Lakhs /-

BOQ Items

Name of Work:REPAIRS TO INTERNAL AND EXTERNAL ELECTRIFICATION INCLUDINGAPFC AT VISHWA VIHAR UNDER GE (AF) MARATHAHALLI
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring of any type of batten or conduit (Light, Fan, Socket or power) complete removing material from site and making good the disturbed surfaces of walls, roofs etc including two coats of white/colour washing/distempering etc to match the existing complete all as directed by EIC.
2Taking down carefully unserviceable sub main wiring of any size and type including making good the disturbed surfaces of walls, ceilings etc including two coats of white /colour washing/ distempering etc to match the existing complete all as directed by EIC.
3Taking down carefully unserviceable distribution boards/metal enclosures of any type and capacity including wooden board and making good the disturbed surfaces of walls, ceilings etc including two coats of white/colour washing/ distempering etc to match the existing complete all as directed by EIC.
4M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good towalls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbedsurfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuousearth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for One light point controlled by one, one way switch.
5All asper Item No.04 above butOne fan point controlled by one, one way switch.
6All asper Item No.04 above but one light point controlled by 2 way switch.
7All asper Item No.04 above butfor One 3 pin, 05 /06 Amps socket outlet point on same board controlled by one , one way 05/06 Amps switch
8All asper Item No.04 above butfor One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch
9All asper Item No.04 above butcapping cassingwiring One Light/fan point controlled by one, one way switch.
10All asper Item No.04 above butcapping cassing wiring for One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch
11M & L point wiring with 2.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good towalls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbedsurfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuousearth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for one 15 /16 Amps socket outlet point on independent
12All asper Item No.11above butcapping cassing wiring for One 3/5 pin, 15 /16 Amps socket outlet point on independent board with 2.5 sqmm cables.
13S &switch piano flush type, 05/06 Amps single pole, one way 240 volts complete all as specified & directed
14Supply & fixing of socket outlet 3 pin, 05/06 Amps (2-in-1 Multipurpose) flush type 240 volts complete all as specified & directed.
15Supply & fixing of socket outlet 3 pin, 15/16 Amps (2 -in-1 Multipurpose) flush type 240 voltscomplete all as specified & directed.
16Supply & fixing switch piano flush type, 15 /16 Amps single ploe, one way 240 voltsall as specified & directed
17Supply & fixing of ceiling rose surfacethree terminals complete all as specified & directed.
18Supply & fixing in repairs bell push flush type 5 Ampscomplete all as specified & directed.
19S & F in repairs Door bell AC, 230 volts, single pole in replacement of old u/s bell/ buzzer complete all as specified & directed..
20Supply & fixing in repirs Switch socket combination 2-in-1, 3 pin, 5 and 15 Amp flush type complete all as specified & directed..
21Supply & fixing Switch in repairs socket combination 2-in-1, 3 pin, 5 Amp flush typecomplete all as specified & directed..
22Supply & fixingin repairs modular switch 06 Amps 1 module complete all as specified & directed
23Supply & fixing in repairs modular switch2 way , 06 Amps 1 module complete all as specified & directed
24Supply & fixing in repairs bell push modular type 6 Amps complete all as specified & directed.
25S & F modular in repairs socket 06 Amps 2/3 pin combined 2 module complete all as specified & directed.
26Supply & fixing in repairs modular switch 16 Amps 1 modulecomplete all as specified & directed
27S & F modular in repairs socket 06/16 Amps 2/3 pin combined 2 modulecomplete all as specified & directed.
28S & F electronic in repairs fan regulator modular type, 2 module, 120Wincluding complete all as specified and directed.
29S & F in repairs electronic fan regulator stepped, socket type 40W including removing the switch board panel and making the provision for fixing the electronic type regulator and refixing the same complete all as specified and directed.
30S & F MCB DB SPN 4Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existingcomplete all as specified and directed.
31S & F MCB DB SPN 8Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existingcomplete all as specified and directed.
32S & F MCB DB SPN 12Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existingcomplete all as specified and directed.
33S & F in repairs MCB DB TPN 4Way, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existingcomplete all as specified and directed.
34S & F in repars MCCB DB VerticalTPN 8 Way"A" Frame,Including MCCB TPN 125 Amp Beaking capacity 25Ka -01 nos,Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing complete all as specified and directed.
35M & L for sub main wiring complete with two runs of 2.5 Sqmm single coreFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. (Two runs of 2.5 Sqmm single core with one run of PVC insulated solid copper conductor 2.5 Sqmm single core as earth continuity conductor and PVC conduit shall be measured as one unit)
36M & L for sub main wiring complete with three runs of 4 Sqmm single coreFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 4.0 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. (Two runs of 4.0 Sqmm single core with one run of PVC insulated solid copper conductor 4.0 Sqmm single core as earth continuity conductor and PVC conduit shall be measured as one unit)
37M & L for sub main wiring complete with two runs of 10 Sqmm single coreFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 10.0 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. (Two runs of 10.0 Sqmm single core copper conductors with one run of PVC insulated solid copper conductor 10.0 Sqmm single core as earth continuity conductor and PVC conduit shall be measured as one unit)
38Material and labour for Cutting, chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, chills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealedconduit wiring etc; and making good, cutting not exc 10 cm girth complete all as specified and directed.
39S & F MCB SPN 40Amps, "C" series, 240 V complete incl making conections all as specified and directed.
40S & F MCB SP 6-32 Amps, "C" series, 240 V complete incl making conections all as specified and directed.
41S & F MCB TPN 63 Amps incl making connections all as specified and directed.
42S & F MCB TP 63 Amps incl making connections all as specified and directed.
43S&F in repairs Lumiline LED tube withbox type fitting , 2 feet, 10 watts alongwith tube complete all as specified and directed.
44Supply and fixing in repairs LED lights fitting 1x 18W, 220V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
45S&F in repairs lumiline LED tube with box type fitting Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environment, friendly, energy efficient 4Ft of 20 Watts and making all necessary connections in the existing fittings and refixing the same back to its position complete all as specified and directed.
46Supply & Fix in repairs linear LED T8 tubular lamp 18Wwith extruded aluminium/PC body and PC diffuser complete with inbuilt driverincl making necessary connections in the existing fittings to suit the LED tube complete all as specified and directed.
47S & F in repairs LED fitting of 6 watts - Square surface mounted LED flat panel down light, PDC aluminum housing and PMMA diffuser makes it a robust Luminaire alongwith 6W LED lamp complete all as specified.
48Supply only LED lamp10 watt complete all as specified and directed.
49Supply only LED lamp5 watt complete all as specified and directed.
50S&F energy saving new generation 10W LED IP65 bulkhead luminaire with opal diffuser complete with and incl 10W LED all as specified and directed.
51Taking down ceiling fan/Exhaust fan, sealing the cable ends dismantling the fan blade kept in safe costody complete all as specified. Note: (a) Servicing and Spares will be measured and paid seperately .
52M & L for painting of ceiling fan complete, at site with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust all as specified.
53Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as specified ,and any addn/alteration /threading if required to down rod shall be done by contractor with out any extra cost.
54Labour for servicing the ceiling / exhaust fan of any make including greasing /oiling /repairs and replacing the spares such as cater pin unserviceable / rusted bolts, split pins, rubber wheel, bearing, washers, bush all as specified and directed .
55Supply only GM bush of ISI marked suitable for ceiling fan of size 1200 / 1400mm sweep.
56Supply only ball bearing suitable for ceiling fan of 1200 /1400mm sweep. Make : SKF, bearing No 6202 or equivalent in NBC.
57Replacement of old unserviceable capacitors 2.5 MFD of the fan in position as directed by Engr - in - Charge
58Replacement of old unserviceable capacitors 4.0MFD of the fan in position as directed by Engr - in - Charge
59M & L for dismantling the defective exhaust fan motor by taking out the burnt copper winding, rewinding the motor with super enamelled copper winding wire of existing gauge and weight including replacement of all insulation material, "O" rings and other petty items required for making motor functional and checking the winding leak proof complete all as specified and directed.
60M & L for dismantling the defective Ceilingfan motor by taking out the burnt copper winding, rewinding the motor with super enamelled copper winding wire of existing gauge and weight,warnishing , including replacement of all insulation material, and other petty items required for making motor functional and checking the winding leak proof complete all as specified and directed.
61M&L for straight through joints (epoxy) heat shrinkable type for UG cable including joint kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor upto 16/25 Sqmm 3.5 core complete all as specified and directed. (Make : 3M /Densons).
62All as per ser item no. 61. here-in-before but of size upto 35/50 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons).
63All as per ser item no. 61 here-in-before but of size upto 95to 150 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons).
64All as per ser item no. 61 here-in-before but of size upto 150/185 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons).
65All as per ser item no. 61 here-in-before but of size upto 240/400 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons). Note for ser item nos 61 to 65: Excavation and earth work shall be measured and paid seperately.
66M & L for Fault locating of LT UG cables by using measuring instruments and rectification of the same by using epoxy cable joints of suitable size of cables and testing the phase contuinity of the cable complete all as specified and directed. Note : Cable joint kit and Excavation/earth work shall be measured and paid seperately.
67Supply & Fix in repairs MCCB TPN 415 Volts 250 Amps rating with breaking capacity of 35 kA with adjustable thermal & magnetic release complete with making all connections as per site requirement as specified and directed.
68All as per ser item no.67 here-in-before but MCCB TPN 415 Volts 100 Amps, 25 kA complete with making all connections as specified and directed.
69All as per ser item no.67 here-in-before but MCCB TPN 415 Volts 63 Amps, 25 kA complete with making all connections as specified and directed.
70Supply and fixing in repairs four pole changeover switch disconector with advance neutral 415 volt 50 Hz 100/125 amps in sheet steel enclosure and Conforming to IS / IEC: 60947 - 3 complete all as directed. Make - L & T /Siemens/Schneider.
71Supply and fixing in repair for swich disconnector fuse unit in sheet steel enclosure TPNcurrent rating 200 Ampwith HRC Fuse including disconnecting and taking out unserviceable one complete all as directed.Make - L&T / Havells / HPL .
72Supply and erecting steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-22 (8.5 meter long) complete, Including disconnectingand taking outold damage PCC pole all as directed. (Note Excavation & Earth work andPCCfoundation/baseshall be measured and paid separately under relevant items of this BoQ)
73M & L forCross arms, bracing, supports, clamps and back plate, fabricated from structural steel sectionincluding nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .
74Dismantling and taking out servicablecross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed.
75M & L for painting the surface of post top poles of size 50mm dia and 3 mtr length by applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-charge.
76M & L forPainting ofsteel pole/PCC polewith cross arms, clamp of any length and shape for LT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia yellow circle & markingsix black & four yellow bends width 15 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height and providng three nos of Red ,Yellow & Blue of reflecting strip of 25 mm width adhesive PVC tape around the pole at suitable heightcomplete all as specified and directed.
77Excavation in trenches in soft /loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete.
78Excavating in trenchesexceeding 1.5 m wide and not exceeding 3 m depth and not less than 1.5 min depth for laying of cables & foundation of poles , stay assembly and getting out in any type of soil complete all as specified and directed .
79Returning filling including spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick each complete all as specified.
80Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified.
81Sand (Tibba) cushioning to cables with a layer of sand 8 cm deep before laying the cable and 15 cm depth after laying of cable, complete all as specified.
82Brick protection cover on cable with sub class "B" brick, laid dry and flat adjacent to each other complete all as specified.
83M & L for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed.
84All as per Srl item No 83 here in above but GI pipe of size 80 bore
85Taking up underground unservicable cable of any size from existing trench including bricks, etc and removing of materials from work site all as directed by Engr-in-charge.
86Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 400 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed.
87All as per Srl item No 86 here in above but size of cable 16 Sqmm 4 core
88All as per Srl item No 86 here in above but size of cable 10 Sqmm 2 core
89All as per Srl item No 86 here in above but size of cable 25 Sqmm 4 core
90All as per Srl item No 86 here in above but size of cable 95 Sqmm 3.5 core
91All as per Srl item No 86 here in above but size of cable 50 Sqmm 3.5 core
92S&F in repairs single pole and neutral enclosure with two pin and earth plug and socket including 1 No. MCB 20 Amp capacity complete all as specified and as directed
93Supply and fixingin repairs of 1100 Volts grade heavy duty cable 10 Sqmm 2 corewith PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulated hanger not more than 1 mtr a part including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed by Engr-in-Charge.
94Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for0.4 mpa working pressure.
95M & L for Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 5 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15cm c/c both way for cover and MS frame etc., complete all as specified.
96Material & labour for fixing of Earth continuity conductor GI strip of size 25X 4 mm with nut bolts at joints , fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles,equipments or any other indicated situation for loop earthing etc, strip fixed onwith epoxy insulatorof suitable size all as specified and directed by Engineer-in-Charge.
97S&F in repairs New generation, post-top lantern of 40 Watts, 240V, energy saving, environmental friendly, long life aestheticallydesigned with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source including making all necessary wiring, provn of suitable fitments and connecting upto control box complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
98S&F PVC Junction box of size 255X200X100mm inside dimension fixed on pole by means of mild steel clamps with hinged door,bolt and nuts, provn for cable entry for incoming and outgoing including MCB 2.5 amps-1 No and 4 way connector-1nos neccessary connection duly fixed with clamps on pole and including cable glands threaded type IP55/IP65 made of polymide with lock nut complete all as specified. Make : Sintex GSJB2520 or equivalent.
99M&L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations for electric poles, filling and mass concrete complete all as specified and directed.
100M & L for PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in coping of the LT poles including form work complete all as specified
101Supply and fixing in repairs of Endura Citylite Platinum, 45 WLED Street Light fittingpressure die cast aluminium housing, heat resistance toughened glass, IP-66 protection complete all as specified and directed.
102Supply and fixing in repairs of Endura Cityliner Neo, 72 W LED Street Light fitting pressure die cast aluminium housing, heat resistance toughened glass, IP-66 protectioncomplete all as specified and directed.
103Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
104Taking out the u/s Street light fitting driver and S&F LEDDriver unit suitable for 30 to 45 wattcapaity complete all as specified and directed Make - Bajaj /CG/Philips/Havells
105S & F in repairs IP68 LED fountain light LED pool light Led underwater light, piscina , 3W 12VAC Led landscape spot lamp LPL-A-3W-12Vincluding making connections complete all as specified and directed.
106Maintenance for APFC panel Out door/indoor Type APFC panel (In door Type) 150 (6x25) KVAR -01No,APFC panel (In door Type) 200 (6x25,4x12.5) KVAR -01No, APFC panel (In door Type)150 (4x25,4x12.5) KVAR -01No, capacitors, internal wiring,inrush current limiting coil, auxilary contactor, indicating lamps, auto-manual selector switch, MCCB ,axial flow fan and replace the unserviceable parts. The following checking will be carried outto ensure smooth and effective operation all the timeall as specified and directed. (a) Checking of the control panel,power supply, fuses ,circuits etc and tighten to any loose contact.(b)Checking of the helthiness of capacitors,contactors and APFC relays. (c)Cleaningof the panel by using blower without any distrubance/damages.(Note:- Spares will be measure and paid seperately )
107Supply only Capacitor (MPP, Heavy duty) 440 volts with inrush current limiting coil, 5 KVAR
108Supply only Capacitor (MPP,Heavy duty) 440 volts with inrush current limiting coil, 10 KVAR
109Supply only Capaitor duty contactor 7 KVAR
110Supply only Add on Auxiliary contact Block 4 NO
111Maintenance of storage type electric water heaters(Geyser) of storage capacity 25 ltrs comprising of the following tasks and all as per specified and directed by Engr-in-Charge. (a) Inspection taking down, opening (dismantling),descaling, brushing cleaning of storage tank and painting internally with one coat of proprietary bituminous compositions not liable to impart taste or or odour or otherwise contaminate the water. (a) Examine water tightness of storage tank after cleaning. (b) Carry out operation of all stop cocks,pressure reducing valves etc to ensure free movement of the working parts. (c) Replacement washers and glands of all taps and ball valves to ensure water tightness. (d) Visual examination of fusible plug to (e) Descaling of the immersion type heating element and cleaning with diluted hydrochloric acid or "clear pedette" solution and testing before refitting. (f) Replacement/repair of neon lamp/indicator lamp. (g) Replacement of the rubber/PVC gaskets to ensure water tightness.. Note : (i) Attending complaint during the currency contract periodon phone call and rectification with in 24 Hrs. (ii)The spares will be measured and paid seperately.
112All as per Item No-111 above,but of 50 ltrs storage capacity.
113Supplyonlynew heating elementsuitable to existing model and make 2 KW Dual clip type/tri angle type and round type with rubber gasketsuitable for geysers up to 25/50 Ltr capacity . Make: Theeta /Elteck or equivalent
114Supplyonlynew heating elementsuitable to existing model and make 1.5 KW Dual clip type/tri angle type and round type with rubber gasketsuitable for geysers up to 25/50 Ltr capacity . Make: Theeta /Elteck
115Supply onlythermostat clip type (Range 30 C to 80 C and acting at 70 C) forgeysers up to 50 Lts.range 30 C to 80 C and acting at 70 C all as specified .
116Supply only PVC connections up to 600 mm in length suitable to connect GI pipe 15 mm dia to hot water outlet of geyser.
117Supply only PVC connectionsup to650 mm in length suitable to connect GI pipe 15 mm dia to cold water inlet of geyser.
118Supply onlypressure release valves suitable for geyser up to 50 ltrs capacity
119Supply onlyindicating lamps green / red suitable forgeysers up to 50 Ltrs
120Supply only HRFR PVC insulated copper flexible cable 3 core 2.5 Sqmmand PVC sheathed 1100 volts grade
121Taking down unserviceable plug top and supply and fixing plug top 3 pin 15 amps 230 volts complete all as specified and directed.
122M&Lfor arresting the leakage in inner tank of any size/make of geysercomplete with brazing work and leak test, servicing etc
123S& F Non return valve of size 1/2"
124Material and labour for painting ofstorage type electric water heaters(Geyser) of storage capacity 25/50ltrs painting with one coat of synthetic enamel paint( as per exsisting colour)all as per specified and directed by Engr-in-Charge.
125Supply and fixing in repairsdigital type Ampere meterrange 0 –400/300/200 Amps, with built in selector switch includingCTs with proper ratio, square type, flush mounted of size 96 mm x 96 mm including making connection with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge.
126Supply and fixing in replacementdigital type Volt meter with built in selector switch, range 0 – 500 volts, square type, flush mounted of size 96 mm x 96 mm including making connection with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge.
127S&F Celing Fan complete with blades , down rods ,elcetrinic regulator and acessories , 230 volts, 1200 mm sweep , min air delevery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor complete all as specified and directed.
128Material and labour for Cleaning and preparation of old painted surface of LT panel board complete and painting with one coat of synthetic enamel paint (exsisting colour) on surfaces of panel boardall as specified and directed by Engineer-in-Charge.
129Supply and fix electric water heater,storage type steel body with SS inner tank and heating element upto2 KW capacity 25 litre, BEE 5 Starrated complete with all accessoriessuch as safety valve, thermostate,NRV, connection piece etc.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail