| 1 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Removing excavated materialn exc 50mand depositing where directed at a level n exc 1.5m above the starting pointcomplete all as specified and as directed . |
| 3 | M&L for moorum/red bajri filling inpavings, laid in layers n exc 15 cm thick, spread, levelled and rammed including watering etc complete all as specified and as directed . |
| 4 | M/L for Hard core of gauge n exc 63mm,deposited,spread and levelled in layers n exc 15 cm thick,watered and well rammedto a true surface complete all as specified and as directed |
| 5 | M&L for100mm thick Plain Cement Concrete(PCC)(1:4:8), Type D-2,in sub base ofhardstandingcomplete all as specified and directed |
| 6 | M&L for sand cushioning for receiving precast PCC interlocking paverblocks, wateringand consolidationcomplete all as specified and directed. |
| 7 | Supply and fix machine pressed precast concrete interlocking paver block, any shape and size, withand including grey cement & pigment conforming to IS 15658-2006 of 60 mm thickness, M-35Grade of concrete,complete all as specified and as directed. |
| 8 | Material and labour for providingPlain Cement Concrete(PCC) in (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete etccomplete all as specified and directed . |
| 9 | M&L forproviding plain cement concrete in (1:2:4), Type B-0using 12.5 mm graded crushed stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 10 | Material and labour for providing precast reinforced cement concrete, type B1, 1:2:4 using 20 mm graded crushed stone aggregate,in Cover slab, window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc.and setting in mortar 1:4, complete all as specified and directed. ( Note : Reinforcementshall be measured and paid for separately.) |
| 11 | M & Lbrick work with sub class \"B\"fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar (1:4)complete all as specified and directed. |
| 12 | M&L for rendering 10mm thick in CM 1:6 on fair faces of brick or concrete surfaces of internal walls, finished fair and even without using extra cement complete all as specified and as directed. |
| 13 | M&L 200mm boreReinforced concrete pipes, class NP3, laid and jointed complete withand including collars complete all as specified and as directed. |
| 14 | M&L formwork to face of walls, retaining walls, abutments parapets and staircase railing and similar work including attached pillasters,buttresses etc, vertical or to batter, for rough finished surfaces of concrete complete all as specified and as directed |
| 15 | M&L for RCC (Nominal mix )(1:1.5:3),Type A-1 using20 mm graded crushed stone aggregate as in wall and the like, any thickness,completeall as specified and as directed. |
| 16 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed. |
| 17 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 gradePlain Cement Concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete complete all as specified and directed. |
| 18 | Supply, errection, testing and commissioning16 M high mast light system with and includingits accessories (Hot dipped galvanised). Mast shaft shall be in two sections (Top/Bottom-150/410mm, sheet - 3/3mm) , suitable for 180Km per hour wind speed as per IS 875. It shall also include accessories \"for high mast including head frame, stainless steel wire rope 6 mm dia (7/19 construction), trailing cable, double drum winch500KG, Galvanised Lantern carriage arrangement suitable for 12 luminaires \"symmetrically & its control gear boxes and lightning arrestor spike finial. The mast shall have an integral power tool motor 1 HP, manual handleinstalled inside the base compartment for its operation. (Make Bajaj/ Surya/ Wipro/ Havells/ Crompton). The following items/specifications are also included in theunit rate quoted against this item :-(a)Provision of foundation bolts with plates (24 x 850mm-6 Nos) manufactured from special steel along with nuts, washers, anchor plates and templates-01 Set(b) Single dome aviation obstruction light LED type -01 No (c) Construction of RCC foundation with 1:1.5:3 ( Nominal Mix) concrete for the highmastas per Manufacturer\"s technical literature, consideringsafebearing capacity of soil as 10 T/Sq mtr at 2 metre depth from AGL,with all materials and labour including excavation, earth work and removal of surplus soil upto 50 metre -01 Job(d)Outdoor, stand mounted feeder pillar with 32A TPNMCB &Timer, 100W, 3 Way light-01 set (e) Erection of the high mast with the help of suitable equipments andwiring of luminaires with all wiring materials and labour. |
| 19 | Supply and fixingHigh efficiency LED flood lights 150W with pressure die cast aluminium housing in rectangularshape and toughened glass in the front ( IP66),suitable for Area lighting complete all as specified and directed.( Make : Orient (Model Sigma Ultra)or equivalent in Surya/Havells/ Crompton/ Bajaj/Phillips/Wipro as approved by GE) |
| 20 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 70 sqmm, 3.5 coreand testing on completioncomplete all as specified and as directed.( Note : Excavation and earthwork, sand cushioning and cable protection will be measured and paid for separately against relevant items of this BOQ.) |
| 21 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 16 sqmm, 4 coreand testing on completioncomplete all as specified and as directed.( Note : Excavation and earthwork, sand cushioning and cable protection will be measured and paid for separately against relevant items of this BOQ.) |
| 22 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed. |
| 23 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 24 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point including spreading complete all as specified and directed. |
| 25 | Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. ( Note : Punned thickness shall be measured. ) |
| 26 | Supply and laying un-reinforced precast concrete cable covers, Class LV, Type I, flat, size 250 mm x 150 mm x 40 mm, complete all as specified and as directed. |
| 27 | Supplying and fixing/ laying of 40mm bore dia GI pipe light grade in trenches/ under roads/ along pole/ wall including all fittings, ISI marked as required for cable protectionincluding dismantling of old unserviceable GI pipe completeall as specified and directed. |
| 28 | Supply & fixing of automatic outdoor light switch with pole mountable enclosure consisting of NATURE SWITCH-02, power contactor for load switching, MCB, and terminal blocks. Switch shall be designed for automatic control of outdoor lighting, using Space Grade Sensors and an advanced micro controller. Enclosure shall consist of mounting brackets, cable glands, openable door with lock and key. Enclosure shall be made out of UV stabilized, FR grade special moulding compound to provide a rust proof, electric shock proof, termite proof, outdoor mountable electrically insulating body capable of enduring solar radiation in the outdoor conforming to IP-66. Power 5kW three phase, contactor rating 25 Amp (AC3) conforms to IEC- 60947-4-1/ IS-13947-4-1 and MCB rating 32 Amp conforms to IEC- 60898/ IS- 8828. Circuit wiring shall be minimum 10sqmm copper conductor cable as asked by GE including making all necessary connections and testing on completion complete all as specified and as directed. Brief specification of light sensitive unit are as under:- (a)Model No. :NATURESWITCH- 02(b)Operating Voltage :230 Vac 50 Hz + 20%(c)Switching Endurance :Minimum 5,000 cycles(d)Operating Illuminance Levels (i) For Switching ON:< 60 lux for >30 sec (ii)For Switching OFF :>10 lux for >30 sec (e)Auto Voltage trip levels(i)High Voltage Trip/auto reset : > 285VAC /< 270 VAC (ii) Low voltage Trip/autoreset:< 150 VAC/ > 165 VAC(f)Operating state indication:Through LED.(g) Duration based switching OFF option :4 to 8 Hrs. with a resolution of ½ hours(h) Override options : Cont. ON and cont. OFFMake:- Cat/ Model No.Swadeep - 66-5kW3P of M/s Kakatiya Energy System Pvt Ltd or equivalent model of make: Bajaj or Healer as approved by GE. |
| 29 | M&L for earthingcomplete with galvanised ironearthplate electrode 600x600x6mm thick,burrieddirectly in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe light grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge8 mesh per linear including50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS TMTbar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed.Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rate as quoted by the contractor. |
| 30 | M&L for earthingcomplete with galvanised ironearthplate electrode 600x600x6mm thick,burrieddirectly in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised ironwire 4mm dia,by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe light grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge8 mesh per linear including50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS TMTbar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed.Note:- GI wire and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rate as quoted by the contractor. |
| 31 | Supply, install, testing & commissioning of outdoor type floor mounted cubical type double door LT distribution panel board, dust and vermin proof made out of 3.15mm thick CRCA sheet and 40x40x5mm thick iron angle frame duly powder coated.The LT panel shall be suitable for 3 phase 4 wire system 440 volts 50 Hz duly prewired with 400Amps copper bus bar for MCCBs and single core PVC insulated multistranded copper conductor 110 volts grade of suitable size and comprising of following:-(a) MCCB 200 Amps 25 KA 415 Volts, 4 pole -01 No (As incomer)(b) MCCB 63 Amps 25 KA, 415 volts 4 pole - 2 Nos (outgoing for Store bldgs,-01 No, URC-01 No)(c) MCCB 40Amps 16KA, 415 Volts 4 pole-02 Nos (01 for highmast, 01 spare)(d) Space for fixing of MCCB upto 100Amps for future load.(e) Space for accommodating automatic time swtich(f) Ammeter 0-50 Amps with suitable CTs and Selector switch(g) Voltmeter 0-500 Volts with selector switch(h) Neon indicating lamp RYB |
| 32 | Schedule of credit amount of Rs. NILto be deducted during AOC |