Repair And Maintenance Of Dg Set, Apfc Panel And Other Repair And Maintenance Of Dg Set, Apfc Panel And Other Miscellaneous Works At Af Stn Tezpur Under Ge ( Af ) Tezpur, tezpur-Assam

Military Engineer Services-MES has published Repair And Maintenance Of Dg Set, Apfc Panel And Other Repair And Maintenance Of Dg Set, Apfc Panel And Other Miscellaneous Works At Af Stn Tezpur Under Ge ( Af ) Tezpur. Submission Date for this Tender is 03-09-2022. Diesel Generators Tenders in tezpur Assam. Bidders can get complete Tender details and download the document.




Tender Notice

33489030
Corrigendum : Repair And Maintenance Of Dg Set, Apfc Panel And Other Repair And Maintenance Of Dg Set, Apfc Panel And Other Miscellaneous Works At Af Stn Tezpur Under Ge ( Af ) Tezpur
Open Tender
Indian
Assam
tezpur
03-09-2022

Tender Details

Repair And Maintenance Of Dg Set, Apfc Panel And Other Repair And Maintenance Of Dg Set, Apfc Panel And Other Miscellaneous Works At Af Stn Tezpur Under Ge ( Af ) Tezpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-09-2022
2 01-Sep-2022 Corrigendum1 Other 03-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work:REPAIR AND MAINTENANCE OF DG SET, APFC PANEL AND OTHER MISCELLANEOUS WORKS AT AF STN TEZPURUNDER GE (AF) TEZPUR.
Sl. No. Item Description
1Comprehensive maintenance for a period of twelve months for DG sets of capacity 5-35 KVA installed at various location by cleaning,Oiling,Greasing, topping, calibration, repairs to diesel engine andincluding replacement of spares parts like clamps, V- Belt of any size,pipe with fittings, check the level of coolant in radiator, repairs to leakage in radiator etc. Gaskets & Oil seals, servicing of the Water Pump, calibration of fuel injection pump,repairs of Self Starter, Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including repair/replacement off toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed.( OEM: Cummins/Kirloskar)
2Comprehensive maintenance for a period of twelve months for DG sets of capacity 40-82.5 KVA installed at various location by cleaning, Oiling,Greasing, topping, calibration, repairs to diesel engine andincluding replacement of spares parts like clamps, V- Belt of any size,pipe with fittings, check the level of coolant in radiator, repairs to leakage in radiator etc. Gaskets & Oil seals, servicing of the Water Pump, calibration of fuel injection pump,repairs of Self Starter, Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including repair/replacement off toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed.( OEM: Cummins/Kirloskar)
3Comprehensive maintenance for a period of twelve months for DG sets of capacity 125/160 KVA installed at various location by cleaning, Oiling,Greasing, topping, calibration, repairs to diesel engine andincluding replacement of spares parts like clamps, V- Belt of any size,pipe with fittings, check the level of coolant in radiator, repairs to leakage in radiator etc. Gaskets & Oil seals, servicing of the Water Pump, calibration of fuel injection pump,repairs of Self Starter, Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including repair/replacement off toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed.( OEM: Cummins/Kirloskar)
4Comprehensive maintenance for a period of twelve months for DG sets of capacity 250 KVA installed at various location by cleaning, Oiling,Greasing, topping, calibration, repairs to diesel engine andincluding replacement of spares parts like clamps,V- Belt of any size,pipe with fittings, check the level of coolant in radiator, repairs to leakage in radiator etc. Gaskets & Oil seals, servicing of the Water Pump, calibration of fuel injection pump,repairs of Self Starter, Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including repair/replacement off toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed.( OEM: Cummins)
5Comprehensive maintenance for a period of twelve months for DG sets of capacity 320/380/ 400/500 KVA installed at various location by cleaning, Oiling,Greasing, topping, calibration, repairs to diesel engine andincluding replacement of spares parts like clamps, V- Belt of any size,pipe with fittings, check the level of coolant in radiator, repairs to leakage in radiator etc. Gaskets & Oil seals, servicing of the Water Pump, calibration of fuel injection pump,repairs of Self Starter, Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including repair/replacement off toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed.( OEM: Cummins/Kirloskar)
6NOTES:- (Applicable for BOQ Serial Item No. 1 to 5 here in before) (i) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of DG Sets(ii) Preventive and Corrective Maintenance : The authorised Service Engineer of OEM or OEM Certified agencies shall visit the site once in four months i.e. quarterly for carrying out preventive and corrective maintenance on all the units installed at site. This includes maintenance of all mechanical, electrical and electronic parts/sub-assemblies. Thepreventive maintenance report will be as per the Original Equipment Manufacturer"s instructions and as specified in Particular Specification. The Contractor may claim payment on monthly basis. In that case the payment shall be made with pro-rata basis on quoted rates.(iii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) Tezpur officials or their representatives, The OEM"s authorised service representative or OEM certified agencieswill carry out the required repairs of theunits and appraise GE, Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during comprehensive maintenence period. (iv) Calibration of fuel injection system,servicing of injector nozzles,repair of radiator,overhauling of self starter,replacement of engine wiring system and top overhauling of engine,the scope of which are already included in this BOQ will be excluded from the scope of work under these items. (v) Spares required for replacement will be measured and paid seperately under respective items of this BOQ.
7Calibrating fuel injector system to simulate closely the function of fuel injectors in the fuel injection system of diesel (compression-ignition) engine of 30 KVA to 87.5 KVA capacity DG Set in order to comply with the higher injection pressures,including replacement of minor spares,repair and servicing of injector nozzles,complete all as specified and directed.
8Calibrating fuel injector system to simulate closely the function of fuel injectors in the fuel injection system of diesel (compression-ignition) engine of 160/250/500 KVA capacity DG Set in order to comply with the higher injection pressures,including replacement of minor spares,repair and servicing of injector nozzles,complete all as specified and directed.
9Calibrating fuel injector system to simulate closely the function of fuel injectors in the fuel injection system of diesel (compression-ignition) engine of 380/400/500 KVA capacity DG Set in order to comply with the higher injection pressures,including replacement of minor spares,repair and servicing of injector nozzles,complete all as specified and directed.
10Taking down carefully,radiator and water pump assembly from engine of DG Set of Capacity 125/160KVA for repairing, brazing in leaking points of circulatory pipe line,upper & lower tanks of the radiator assembly if any,descaling and cleaning throughly tanks & circulatory pipeline,cleaning of fins of radiator assembly and water pump internally,includingreplacement of defective spares as required and including reinstallation of the radiator and water pump assembly in original position including testing and commissioning,complete all as specified and directed.
11Taking down carefully,radiator and water pump assembly from engine of DG Set of Capacity 250/320KVA for repairing, brazing in leaking points of circulatory pipe line,upper & lower tanks of the radiator assembly if any,descaling and cleaning throughly tanks & circulatory pipeline,cleaning of fins of radiator assembly and water pump internally,includingreplacement of defective spares as required and including reinstallation of the radiator and water pump assembly in original position including testing and commissioning,complete all as specified and directed.
12Taking down carefully,radiator and water pump assembly from engine of DG Set of Capacity380/400KVA for repairing, brazing in leaking points of circulatory pipe line,upper & lower tanks of the radiator assembly if any,descaling and cleaning throughly tanks & circulatory pipeline,cleaning of fins of radiator assembly and water pump internally,includingreplacement of defective spares as required and including reinstallation of the radiator and water pump assembly in original position including testing and commissioning,complete all as specified and directed.
13Taking down carefully,radiator and water pump assembly from engine of DG Set of Capacity 500 KVA for repairing, brazing in leaking points of circulatory pipe line,upper & lower tanks of the radiator assembly if any,descaling and cleaning throughly tanks & circulatory pipeline,cleaning of fins of radiator assembly and water pump internally,including replacement of defective spares as required and including reinstallation of the radiator and water pump assembly in original position including testing and commissioning,complete all as specified and directed.
14Overhauling of Self Starter 12 Volts of DG Set of capacity 40-160 KVA by opening up,cleaning of parts, lubrication and replacement of defective parts including re-assembling all as required for smooth functioning of self starter,complete all as specified and directed.Notes:-(i) Cost of minor spares such nuts,bolts,screws,washers, insulation sleeves, lugs,lubricants etc. required for maintenance shall be deemed to be included in the unit rate quoted. (ii) Spares required to be replaced shall be measured and paid separately under relevant items of this BOQ.(iii) Spares replaced shall be guaranteed for two years. (iv) Self starter shall be tested in presence of Engineer in Charge and the cost of testing shall be deemed to be included in the quoted rate.
15Supply Only the following spares suitable for Self Starter 12 Volts of DG Set of capacity 40-160 KVA as per OEM"s specifications, all as specified. [Make: LUCAS/TVS/VALEO]
16Clutch Assembly.
17Bendix Pinion
18Solenoid Switch
19Carbon Brush
20Armature Field Coil
21Bush
22Armature assembly
23Overhauling of Self Starter 24 Volts of DG Set of capacity 250-750 KVA by opening up,cleaning of parts,lubrication and replacement of defective parts including re-assembling all as required for smooth functioning of self starter,complete all as specified and directed.Notes:- (i) Cost of minor spares such nuts,bolts,screws,washers, insulation sleeves, lugs,lubricants etc. required for maintenance shall be deemed to be included in the unit rate quoted.(ii) Spares required to be replaced shall be measured and paid separately under relevant items of this BOQ.(iii) Spares replaced shall be guaranteed for two years. (iv) Self starter shall be tested in presence of Engineer in Charge and the cost of testing shall be deemed to be included in the quoted rate.
24Supply Only the following spares suitable for Self Starter 24 Volts of DG Set of capacity 250-750 KVA as per OEM"s specifications, all as specified. [Make: LUCAS/TVS/VALEO]
25Clutch Assembly.
26Bendix Pinion
27Solenoid Switch
28Carbon Brush
29Armature Field Coil
30Bush
31Armature assembly
32Supply and Fix in repairs, maintenance free lead acid battery,12 Volts,capacity 150 Ah,suitable for DG Set including provision of brass terminal clamps for connection,complete all as specified and directed.[Model : Xpress (XP1500) of Make"Exide"or equivalent Model of Make "Amron"/"Amco"]
33Supply and Fix in repairs, maintenance free lead acid battery,12 Volts,capacity 180 Ah,suitable for DG Set including provision of brass terminal clamps for connection,complete all as specified and directed.[Model : Xpress (XP1800) of Make"Exide"or equivalent Model of Make "Amron"/"Amco"]
34Supply and Fix in repair,450 mm long,PVC insulated,unsheathed,heavy duty DC cables with multi stranded copper conductor,of Cross sectional area 25 Sq. mm,single core with copper lugs fitted on both ends suitable for connections of lead acid battery,12 Volts,complete all as specified and directed.
35Supply,laying, jointing and testing of control cables,PVC insulated (Heavy Duty) electric cables with multi stranded copper conductor for working voltage up to and including 1100 volts [IS: 1554 (Part-I)] of Cross sectional area 2.50 Sq. mm, 8 cores, including taking out existing unserviceable cables,complete all as specified and directed.
36Supply and Fix in repairs, 3 Phase LED Ammeter, Accuracy Class 1.0, Aux supply 80-300 VAC, CT secondary side selectable 1A / 5A, flush mounting 96 x 96 mm, with inbuilt selector switch, complete all as specified and directed. [Cat No. WL131010OOOO of Make “L&T” or equivalent Model of Make HPL/ AE ]
37Supply and Fix in repairs,3 Phase LED Voltmeter, Accuracy Class 1.0, Input voltage measurement range 50-550 VAC (P-P), Aux supply 80-300 VAC, CT secondary side selectable 1A / 5A, flush mounting 96 x 96 mm, with inbuilt selector switch, complete all as specified and directed. [Cat No. WL132010OOOO of Make “L&T” or equivalent Model of Make HPL/ AE]
38Supply and Fix in repairs,LED Indicator 16 mm with power consumption < 0.6W, LVGP & surge protection, 64/110 Volts AC/DC / 240 Volts AC,colour Red/ Yellow/Blue, complete all as specified and directed. [Cat No. SIL of Make “L&T” or equivalent Model of Make HPL/ AE]
39Supply and Fix in repairs,cam operated rotary isolator switch,90º operation complete rotation,3 Pole ON - OFF,63 Amps,complete all as specified and directed. [Cat No.61197 of Make “L&T” or equivalent Model of Make HPL/ AE]
40Supply and Fix in repair,switched mode power supply (SMPS) based design battery charger, 12 Volts,10 Amps,charging capacity for 7 AH to 220 AH lead acid battery,with protection against reverse polarity of battery and automatic over current limit & intelligent thermal management,digital display for charging Amp and DC Volt with over voltage, under voltage and current protection and easy battery connection with clip leads,suitable for AMF Panels of DG Sets of capacity 10-160KVA all as per OEM"s reccommendations,complete all as specified and directed.[Part No.02.872.18.0.00 of Make "Kirloskar" or equivalent Part of Make Procom/NHP/Cummins]
41Supply and Fix in repair,switched mode power supply (SMPS) based design battery charger,24 Volts,10 Amps,charging capacity upto 220 AH lead acid batteries,with protection against reverse polarity of battery and automatic over current limit & intelligent thermal management,digital display for charging Amp and DC Volt with over voltage, under voltage and current protection and easy battery connection with clip leads,suitable for AMF Panels of DG Sets of capacity 250-500 KVA all as per OEM"s reccommendations,complete all as specified and directed.[Part No.6H.849.09.0.00 of Make "Kirloskar" or equivalent Part of Make Procom/NHP/Cummins]
42Taking down carefully existing door shutters not exceeding 1 SqM each from aucoustic enclosures of DG Sets,resecuring or easing and adjusting,including replacement of 02 (Two) Nos of defective mild steel hinges as per OEM"s specification,complete all as specified and directed.
43Supply Only distilled water,all as specified. .Note:- Distilled Water shall be supplied in sealed PET bottles of 1 Litres/2 Litres.
44Supply Only,glycol based antifreeze radiator coolant,all as specified.(Make: Castrol/Bosch/Valvoline) Note:- Coolant shall be supplied in sealed HDPE containers of 1 Litres/2 Litres/5 Litres.
45Supply Only,engine oil, viscosity Grade 20W-40,all as specified. (Make: Castrol/Bosch/Servo/Gulf)Note:- Engine Oil shall be supplied in sealed HDPE containers of 5 Litres/20 Litres.
46Supply Only the following spares for 320KVA/380KVA/400KVA/500 KVA DG Sets as per OEM"s specifications,complete all as specified.[OEM:Kirloskar]
47Lub Oil Filter, Part No.- DV0.014.11.0.00.
48Lub Oil Filter,Part No.- DV0.014.27.0.00
49Fuel Filter Cartridge,Part No.-DV0.020.03.0.00
50Air Cleaner Primary Element,Part No.-DV8.505.74.0.00
51Air Cleaner Safety Element ,Part No.- DV8.505.75.0.00
52Supply Only the following spares for 250 KVA DG Sets as per OEM"s specifications,complete all as specified.[OEM:Kirloskar]
53Spinon Lube Oil Filter , Part No..- 06.436.01.0.00
54Fuel Filter Kit 1.1 Ltr, Part No..- 48.999.20.0.00
55Air Cleaner Safety Element for 12K22TA Engine Fleet Gaurd 14", Part No..- KV2.505.03.0.00
56Air Cleaner Primary Element for 12K22TA Engine Fleet Gaurd 14", Part No..- KV2.505.02.0.00
57Supply Only the following spares for 160 KVA DG Sets as per OEM"s specifications,complete all as specified. [OEM:Kirloskar]
58Spinon Lube Oil Filter , Part No..- 06.436.01.0.00
59Fuel Filter Element Primary, Part No.. - 3H.132.01.0.00
60Fuel Filter Element Secondary, Part No..- 3H.132.02.0.00
61Air Cleaner Primary Element, Part No..- 6H.413.02.0.00
62Supply Only the following spares for 125 KVA DG Sets as per OEM"s specifications,complete all as specified. [OEM:Kirloskar].
63Spinon Lube Oil Filter , Part No..- 06.436.01.0.00
64Fuel Filter Kit 1.1 LTR, Part No..- 48.999.20.0.00
65Safety Air Filter Element, Part No..- 6H.411.01.0.00
66Primary Air Filter Element, Part No..- 6H.411.02.0.00
67Rubber Hose: Main Pipe 100X100X180L, Part No..-F6.680.06.0.00
68Lubricant oil pump assembly -6H.047.30.0.00
69Lubricant oil pressor sandor -2H.092.11.0.00
70V-Belt -4H.069.01.0.00
71Supply Only the following spares for 62.5KVA/82.5KVA/87.5KVA DG Sets as per OEM"s specifications,complete all as specified.[OEM:Kirloskar].
72Spinon Lube Oil Filter , Part No..- 06.436.01.0.00
73Fuel Filter Kit 1.1 LTR, Part No..- 48.999.20.0.00
74Primary Filter Element, Part No..-06.757.03.0.00
75Safety Air Filter Element, Part No..-06.757.04.0.00
76Fuel Pipe: Fuel Filter to FIP, Part No..- 4H.031.04.0.00
77Fuel Pipe Feed Pump to Fuel Filter, Part No..- 4H.031.05.0.00
78Governor Card, Part No..- F6.1005.01.0.00
79Supply Only the following spares for 25 KVA/30 KVA/50 KVA DG Sets as per OEM"s specifications,complete all as specified. [OEM:Kirloskar].
80Spinon Lube Oil Filter, Part No..- 04.270.01.0.00
81Fuel Filter Element Primary, Part No..- 3H.132.01.0.00
82Fuel Filter Element Secondary, Part No..- 3H.132.02.0.00
83Primary Air Cleaner Element, Part No..- 04.586.03.0.00
84Air Cleaner Safety Element, Part No..- 04.586.04.0.00
85Oil Bath Air Cleaner with Rubber Sleeve, Part No..-03.061.70.0.00
86Supply Only the following spares for 10 KVA/15 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
87Lube Oil Filter Element, Part No..- 03.040.19.0.00
88Pre Filter Element, Part No..- 34.032.02.0.00
89Fuel Filter Element, Part No..- 34.032.12.0.00
90Primary Air Cleaner Element, Part No..- 04.586.03.0.00
91Air Cleaner Safety Element, Part No..- 04.586.04.0.00
92Supply Only,Genset Controller 7320 MK II, all as per Part No.- DV0.858.05.0.00 for 250 KVA to 500 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
93Supply Only,Magnetic Pick Up 16X1.5 Thread,all as Part No.- F6.741.16.0.00 for 250 KVA to 500 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
94Supply Only,Thermostat Element,all as per Part No.- for 250 KVA to 500 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
95Supply Only,Rotating Rectifier Assembly with 6 Nos. Diodes and Heat Shrink Alternator Frame, all as per Part No.-KV8.801.14.0.00 for 350 KVA to 625 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
96Supply Only,Automatic Voltage Regulator AVR,all as per Part No.-03.217.24.0.00 for 250 KVA to 500 KVA DG Sets as per OEM"s specifications,complete all as specified.[OEM:Kirloskar].
97Supply Only,Lube Oil Pressure Sendor 0.75 +/- 0.15 B,all as per Part No.-21.279.04.0.00 for 250 KVA to 500 KVA DG Sets as per OEM"s specifications,complete all as specified.[OEM:Kirloskar].
98Supply Only,Lube Oil Temperature Gauge,all as per Part No.-34.183.03.0.00 for 250 KVA to 500 KVA DG Sets as per OEM"s specifications,complete all as specified.[OEM:Kirloskar].
99Supply Only,Stop Solenoid Assembly: 24VDC,all as per Part No.-F6.399.10.0.00 for 250 KVA to 500 KVA DG Sets as per OEM"s specifications,complete all as specified.[OEM:Kirloskar].
100Supply Only,Fuel Stop Solenoid Assembly,electral control stop type,24VDC with suitable linkage & hardware,all as per Part No.-F6.1356.20.0.00 for 250 KVA to 500 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
101Supply Only,Low Oil Pressure Switch 1.7KG/CMSQ,all as per Part No.-49.156.01.0.00 for 250 KVA to 500 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
102Supply Only,Rotating Rectifier Assembly with 6 Nos. Diode&Heat Sink S/F KG Alternator, PartNo.AG250320RRA(250&320KVA)(FRAMESIZE TA284L1&TA284C),all as per Part No.-F6.814.16.0.00 for 250 KVA & 320 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
103Supply Only,Thermostat Element,all as per Part No.-KL6.055.33.0.00 for 125 KVA to 250 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
104Supply Only,AVR Model TAVR-3A S/F KG Alternator (140,160,180 & 200 KVA)(FRAME SIZE TA254SO,TA254S1,TA254MO&TA254M1),all as per Part No.- F6.814.11.0.00 for 140 KVA,160 KVA,180 KVA &200 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
105Supply Only,Lube Oil Pressure Sendor,all as per Part No.-2H.092.11.0.00 for 125 KVA to 160 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
106Supply Only,Lube Oil Temperature Gauge ELE:40-150/160 D,all as per Part No.-46.085.01.0.00 for 125 KVA to 160 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
107Supply Only,KG645 Controller Unit with 4-20MA,all as per Part No.-02.026.09.0.00 for 10 KVA to 160 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
108Supply Only,Wiring Harness for KG 645: 4R1040,all as per Part No.-4H.905.20.0.00 as per OEM"s specifications,complete all as specified.[OEM:Kirloskar].
109Supply Only,Stop Solenoid Assemblly-12VDC Single Coil,all as per Part No.-4H.150.30.0.00 for 10 KVA to 160 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
110Supply Only,Kirloskar Green AVR (Model : TAVR-10/TAVR-20/TAVR-14),all as per Part No.-2H.811.32.0.00 for 10 KVA to 82.5 KVA DG Sets as per OEM"s specifications,complete all as specified.[OEM:Kirloskar].
111Supply Only,Rotating Rectifier Assembly with Forward and Reverse Diode,all as per Part No.-2H.811.35.0.00 for 25 KVA to 82.5 KVA DG Sets as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
112Supply Only,ADV Load Dump Module 24V DC,all as per Part No.-DV8.858.16.0.00 as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
113Supply Only,24 V DC Relay Board 2CH (70 AMP.) 1C/O. Battery -VE Signal,DIN Mounted,all as per Part No.-KV8.853.05.0.00 as per OEM"s specifications, complete all as specified.[OEM:Kirloskar].
114Disconnection of existing APFC Panel of any capacity/rating, form all incoming and outgoing electrical connections, checking serviceability of each components viz. capacitors,contactors, relays,MCB"s, MCCB"s, indicator lights, display meters,PF controller etc.,replacement of burnt out internal wirings with with suitable size FRLSH PVC insulated multistranded copper conductor wires,replacement of defective lugs,thimbles etc.,replacement of defective parts,through cleaning of panel both internally and externally, re interconnection of parts including reconnection of all incoming and outgoing electrical connections after repairs,testing and commissioning, complete all as specified and directed.Notes:-(i) The work shall be carried out through Authorised Original Equipment Manufacturer"s Service Centre Engineers or through OEM Certified Agencies as approved by the Engineer in Charge.(ii) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
115Supply Only, power factor correction capacitors, box type, heavy duty, with over current withstand capability 1.8 x In,operating losses 0.35 W/kVAr, peak inrush current withstand capability 300 x In, maximum ambient temperature 55º C, minimum operating life 150000 hours,rating 5 kVAr, 440 V, complete all as specified.[Cat No. Box Series: LTBCH of Make “L&T” or equivalent Model of Make Siemens/ Schneider / ABB.]
116Supply Only, power factor correction capacitors, box type, heavy duty, with over current withstand capability 1.8 x In,operating losses 0.35 W/kVAr, peak inrush current withstand capability 300 x In, maximum ambient temperature 55º C, minimum operating life 150000 hours,rating 7.5 kVAr, 440 V, complete all as specified.[Cat No. Box Series: LTBCH of Make “L&T” or equivalent Model of Make Siemens/ Schneider / ABB.]
117Supply Only, power factor correction capacitors, box type, heavy duty, with over current withstand capability 1.8 x In,operating losses 0.35 W/kVAr, peak inrush current withstand capability 300 x In, maximum ambient temperature 55º C, minimum operating life 150000 hours,rating 10 kVAr, 440 V, complete all as specified.[Cat No. Box Series: LTBCH of Make “L&T” or equivalent Model of Make Siemens/ Schneider / ABB.]
118Supply Only, power factor correction capacitors, box type, heavy duty, with over current withstand capability 1.8 x In,operating losses 0.35 W/kVAr, peak inrush current withstand capability 300 x In, maximum ambient temperature 55º C, minimum operating life 150000 hours,rating 12.5 kVAr, 440 V, complete all as specified.[Cat No. Box Series: LTBCH of Make “L&T” or equivalent Model of Make Siemens/ Schneider / ABB.]
119Supply Only,capacitor duty contactors, type MO C5, built in auxillary contacts 1NO,rating 5 kVAr, 440 V, 3 phase, 50 Hz all as specified. [Cat No.CS96127 of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
120Supply Only,capacitor duty contactors, type MO C8.5, built in auxillary contacts 1NO,rating 8.5 kVAr, 440 V, 3 phase, 50 Hz all as specified. [Cat No.CS96320 of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
121Supply Only,capacitor duty contactors, type MO C12.5, built in auxillary contacts 1NO,rating 12.5 kVAr, 440 V, 3 phase, 50 Hz all as specified. [Cat No.CS96321 of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
122Supply Only,APFC controller for contactor switching with 1 CT input 1/ 5 Amp, 415 V, 8 steps (For Contactor Switching) all as specified. [Cat No.CS90902OOOO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
123Supply Only, miniature circuit breaker (MCBs) single pole and neutral, 240 Volts, 10KA,"C" Curve,6 to 32 Amps, complete all as specified. [Cat No. BB20060C/BB20100C/BB20160C/BB20200C/BB20250C/BB20320C of Make L&T or equivalent Model of Make Legrand/ Hager/Seimens/GE/ Schneider/ABB]