Development Of Distribution Infrastructure Of Packageprayagraj 1 At Prayagraj District Of Puvvnluttar Pradeshunderrevamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Supply Of Consumer Service Cable 2 Supply Of Armored Service Ca, prayagraj-Uttar Pradesh

Purvanchal Vidyut Vitaran Nigam Limited has published Development Of Distribution Infrastructure Of Packageprayagraj 1 At Prayagraj District Of Puvvnluttar Pradeshunderrevamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Supply Of Consumer Service Cable 2 Supply Of Armored Service Ca. Submission Date for this Tender is 31-08-2022. Building Work Tenders in prayagraj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33488283
Corrigendum : Development Of Distribution Infrastructure Of Packageprayagraj 1 At Prayagraj District Of Puvvnluttar Pradeshunderrevamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Supply Of Consumer Service Cable 2 Supply Of Armored Service Ca
Open Tender
Indian
Uttar Pradesh
prayagraj
31-08-2022

Tender Details

Development Of Distribution Infrastructure Of Packageprayagraj 1 At Prayagraj District Of Puvvnluttar Pradeshunderrevamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Supply Of Consumer Service Cable 2 Supply Of Armored Service Cable For Consumer Service Connection With Accessories As Per Technical Specifications, Scope Of Works And Approved Drawings 3 Supply Of Single Phase Armored Al Cable Size 2Cx 6 Sq Mm 4 Supply Of Three Phase Armored Al Cable Size 4Cx 16 Sq Mm 5 Supply Of 10 Swg Gi Wire 6 Supply Of 8 Swg Gi Wire 7 Supply Of Gi Pipe / M.S Angle Along With Nails / Clamps / Proper Binding E.T.C. As Per Rec Std. 8 Conversion Of Existing Lt Lines On Bare Conductor To Areal Bunch Xlpe Cable 9 Conversion Of Existing Lt Lines With Bare Conductor To Ab Xlpe Cable Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 10 Supply Of 8.5 M / 180 Kgs Pcc Poles ( Pcc Pole As Per State Practice ) 11 Galvanized Stay Set For Lt Line With Anchor Plate ( 200X200x6mm ) , 50X8mm Stay Clamp, 1 No. Stay Guy Insulator, Nut Bolts, 1 No. Turn Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 12 Conversion Of Existing Lt Lines Using New Earthing As Per Approved Drawings, Technical Specifications And Scope Of Work 13 Supply Of Spike Earthing Made Of 20Mm X 2500 Mm Gi Solid Rod 14 Supply Of 8 Swg Gi Wire For Earthing And Guarding 15 Supply Of Following Lt Ab Xlpe Cable For Conversion Of Existing Lt Bare Conductor Line With Ab Xlpe Cable As Required As Per Technical Specification, Approved Drawings And Scope Of Work: 16 Supply Of Aerial Bunchedxlpe Cable 3 X 50 Sqmm+1X35 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 17 Supply Of Aerial Bunchedxlpe Cable 3 X 70 Sqmm.+1X50 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 18 Supply Of Aerial Bunchedxlpe Cable 3 X 95 Sqmm.+1X70 Sqmm. ( Bare Messenger Wire ) + 1X16 Sqmm. 19 Supply Of Aerial Bunchedxlpe Cable 3 X 120 Sqmm. + 1X95 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 20 Supply Of Pole Mounted Lt Distribution Box As Per Approved Drawings, Technical Specifications And Scope Of Work 21 Supply Of Three Phase Smc Distribution Box With Clamps 22 Supply Of Single Phase Smc Distribution Box With Clamps 23 Supply Of Xlpe Insulated Al. Cable For Energisation Of Distribution Box / Kiosk As Per Approved Drawings, Technical Specifications And Scope Of Work 24 Suppply Of 2Cx25 Sqmm Stranded Unarmoured Cable ( Al Conductor ) For Chargingsingle Phase Db 25 Suppply Of 4Cx35sqmm Stranded Unarmoured Cable ( Al Conductor ) For Chargingthreephase Db 26 Supply Of Stone Pad ( 300X300x75 ) 27 Supply Of Accessories For Ab Xlpe Cable As Per Approved Drawings, Technical Specifications And Scope Of Work 28 Stainless Steel Strap 29 Hdg Lt Pole Clamp With Nut & Bolt For Laying Abc 30 Dead End Clamp With I-Hook ( Insulated ) 31 Suspension Clamp With I-Hook ( Insulated ) 32 95 / 35 Sqmm - 70 / 25 Sqmm Pg Clamps ( For Line To Line Jumpering & Energizing Db Neutral ) 33 120 / 50 Sqmm - 95 / 25 Sqmm Pg Clamps ( For Line To Line Jumpering & Energizing Db Neutral ) 34 Lt Insulation Piercing Connector 120-50 Sqmm - 50-25 Sqmm Size ( For Energizing Distribution Box ) 35 Lt Insulation Piercing Connector 120-50 Sqmm - 120-50 Sqmm Size ( For Line To Line Jumpering ) 36 Lt Insulation Piercing Connector 16 - 25Sqmmsize Suitable For Street Light Connection 37 Pre-Insulated Compression Connectors Size 16 Sqmm Suitable For Ab Xlpe Cable 38 Pre-Insulated Compression Connectors Size 50 Sqmm Suitable For Ab Xlpe Cable 39 Pre-Insulated Compression Connectors Size 70 Sqmm Suitable For Ab Xlpe Cable 40 Pre-Insulated Compression Connectors Size 95 Sqmm Suitable For Ab Xlpe Cable 41 Pre-Insulated Compression Connectors Size 120 Sqmm Suitable For Ab Xlpe Cable 42 Heat Shrinkable Type End Cap For Ab Xlpe Cable 43 Supply Of New 11 Kv Lines : Feeder Segregation ( Agriculture Feeder ) 44 Supply Of Support For 11 Kv Overhead Line As Per Technical Specification, Approved Drawings And Scope Of Work 45 Supply Of 8.5M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 46 Supply Of 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 47 Supply For 3 Phase 11 Kv Line Using New Pre-Fabricated Hot Dip Galvanized Steel Items Like V Cross Arm, Top Channel, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle, Ms Transformer Base Channel, Ms Flats Pole Extension Channel With Welded Plate, Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 48 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle For Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 49 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 50 Supply Of 11 Kv Danger Board 51 Supply Of Stone Pad 300X300x75 52 Supply Of Barbed Gi Wire 12 Swg 53 Supply Of Stay Set ( Galvanized ) With 50X8 Mm Stay Clamp, Stay Guy Insulator ( 1 Nos. ) , Anchor Plate ( 200X200x6 ) , Nut Bolts, 1 Nos Turn-Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 54 Supply Of Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work. 55 Supply Of 11 Kv45 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 56 Supply Of 11 Kv 5 Kn Polymer With Pin Insulators 57 Supply Of Earthing Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 58 Supply Of Spike Earthing 20Mm X 2500 Mm Gi Solidrod 59 Supply Of 8 Swg Gi Wire For Earthing And Guarding 60 Supply Of 6 Swg Gi Wire For Earthing And Guarding 61 Supply Of Acsr Conductors Of Following Sizes With Jointing Sleeves, Binding Materials, Pg Clamps, Bi-Metallic Clamp, Hardware Etc For Overhead Line And Jumpers As Required As Per Technical Specification, Approved Drawings And Scope Of Work 62 Supply Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel 63 Supply Of 11 Kv, 600A, 3-Ph, 3 Pin Type, Vertical Mounting Type, Gang Operated, Ab Switch Along With Support Insulators, Base Channel Down Pipe, Arcing Horns Etc. Complete Asper Technical Specifications, Scope Of Works And Approved Drawings 64 Supply Of 11 Kv Lineunderground Railway Crossing Ensuring Statutory Clearances As Required As Per Technical Specification, Approved Drawings And Scope Of Work 65 Supply For 11 Kv Lineunder Ground Railway Crossing With 2 Nos ( Including One Spare ) 3Cx185 Sqmm Xlpe Armored Cable ( 0.3 Km Each ) Using 150Mm Dia Gi Pipes ( Grade A For Underground Laying And Grade B For Pole Support ) , Outdoor Heat Shrinkable Cable Jointing Kit, 11 Kv Lightening Arrestor Station Class 10Ka ( 6 Nos. ) , Lugs, 4 Nos Gi 3-Meters Long Pipe Earthing, 6 Swg Gi Wires, Cable Markers, Bi Metallick Clamps And Jumpering Etc As Required As Per Technical Specifications, Drawings And Scope Of The Work. 66 Supply Of 11 Lv Line Underground Highway Crossing Ensuring Statutory Clearancesas Required As Per Technical Specification, Approved Drawings And Scope Of Work 67 Supply Of 11 Kv Lineforunder Ground Highway Crossing By 2 Nos ( Including One Spare ) 3Cx185 Sqmm Xlpe Armored Cable ( 0.3 Km Each ) Using 160 Mm Hdpe Pipe At Road Crossing And 150Mm Dia Gi Pipes ( Gradeb For Pole Support ) , Outdoor Heat Shrinkable Cable Jointing Kits, 11 Kv Lightening Arrestor Station Class 10Ka ( 6 Nos. ) , Lugs, 4 Nos Gi 3-Meters Long Pipe Earthing, 6 Swg Gi Wires, 7 / 20 Gi Wire, Cable Markers, Bi Metallick Clamps And Jumpering Etc As Required As Per Technical Specifications, Drawings And Scope Of The Work. 68 Supply Of 12 Kv 3Ph Indoor Type Switch Gear And 11 Kv Xlpe Cable As Per Technical Specifications, Approved Drawings And Scope Of Works: 69 Supply Of Indoor Type 12 Kv 3 Ph 1250 A Vcb With Control And Protection System For Out Going Feeder Consisting Ofct, A-Meter, Volt-Meter, Relays, Energy Meter ( Tvm ) Dlms Compliant & Accessories Complete As Per Specifications For Feeder Breaker 70 11 Kv 3X 185 Sqmm Xlpe Armored Power Cable, Aluminum Stranded Conductor, Including Their Termination Materials Like Indoor And Outdoor Termination Kit, Glands, Lugs, Tagging, Cable Path Marker Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Works. 71 Supply For Augmentation Of Lines 72 Supply For Augmentation Of 33 Kv Line 73 Supply For Augmentation Of 3 Phase 33 Kv Line Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 74 Supply Of 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 75 Supply New Pre-Fabricated Hot Dip Galvanized Steel Item, For Augmentation Of 33 Kv Line, Like V Cross Arm, Top Channel, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle ( 65X65x6mm ) , Ms Flats ( 65X8mm ) Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 76 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle For Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 77 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 78 Supply Of 33 Kv Danger Board 79 Supply Of Gi Barbed Wire 12 Swg 80 Supply For Augmentation Of 3 Phase 33 Kv Line Replacing Existing Conductor With Following Type Of New Acsr Conductor Including Jointing Sleeves, Binding Material, Aluminum Tape And Helical Preformed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 81 Supply Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog Replacing Existing Racoon Conductor 82 Supply Of 30 / 3.00 + 7 / 3.00 Mm ( 200 Mm² Al. Area ) - Panther Replacing Existing Dog / Racoon Conductor 83 Supply Of 33 Kv Under Ground Cable As Per Technical Specification, Approved Drawings And Scope Of Work. 84 Supply Of 3Cx300 Sqmm 33 Kv Xlpe Armored Cable 85 Supply Of 33 Kv3cx300 Sqmm Xlpe Armored Cable ( 2 Nos Including One Spare ) Accessories Like 160Mm Dia Hdpe Pipes For Road Crossing And 150 Mm Dia Gi Pipegrade B For Pole Support Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, Cablepath Markers, Bi Metallic Clamps, 7 / 20 Gi Wire As Per Technical Specification, Approved Drawing And Scope Of Work 86 Supplyof New Insulator And Hardware For Augmentation Of33 Kv Line As Per Technical Specification, Approved Drawings And Scope Of Work 87 Supply Of 33 Kv 70 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 88 Supply Of 33 Kv 10 Kn Polymer Pin Insulators 89 Supply Of New Earthing Arrangement For Augmentation Of33 Kv Line As Per Technical Specifications, Approved Drawings And Scope Of Work. 90 8 Swg Gi Coil 115 Turns ( 1.85 Kg ) 91 Supply Of New Stay Set ( Galvanized ) For 33 Kv Line With 50X8 Mm Stay Clamp, 2 Nos. Guy Insulator, Anchor Plate ( 300X300x8mm ) , Nut Bolts, 1 No. Turn-Buckles, 1.8 M Long, 20 Mm Diameter Solid Gs Stay Rod & 7 / 4.00 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 92 Supply Of New Gi Wire For Earthing And Guarding For Augmentation Of33 Kv Line As Per Technical Specification, Approved Drawings And Scope Of Work. 93 Supply Of 6 Swg Gi Wire 94 Supply Of 8 Swg Gi Wire 95 Supply Of Conductor Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 96 Supply Of Pg Clamp For Dog To Dog Conductor 97 Supply Of Pg Clamp For Panther To Panther Conductor 98 Supply For Augmentation Of 11 Kv Lines 99 Supply For Augmentation Of 3 Phase 11 Kv Line Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 100 Supply Of 8.5 Meter Long / 180 Kg Pcc Poles ( Pcc Pole As Per State Practice ) 101 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Pre-Fabricated Hot Dip Galvanized Steel Items Like V Cross Arm, Top Channel, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle, Ms Flats Pole Extension Canal With Welded Plate, Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 102 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle For Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 103 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 104 Supply Of 11 Kv Danger Board 105 Stone Pad ( 300X300x75mm ) 106 Supply Of Gi Barbed Wire 12 Swg 107 Supply For Augmentation Of 3 Phase 11 Kv Line Replacing Existing Conductor With Following Type Of New Acsr Conductor Including Jointing Sleeves, Binding Material And Helicon Formed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 108 Supply Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel By Replacing Existing Weasel / Squirrel Conductor 109 Supply Of 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit By Replacing Existing Weasel / Squirrel Conductor 110 Supply Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog By Replacing Existing Racoon / Rabbit Conductor 111 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work 112 Supply Of 11 Kv 45 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 113 Supply Of 11 Kv 5 Kn Polymer Pin Insulators 114 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Earthing Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 115 Supply Of Gi Earthing Spike Made Of 20X2500mmsolid Rod 116 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Stay Set ( Galvanized ) With 50X8 Mm Stay Clamp, 1 No. Guy Insulator, Anchor Plate ( 200X200x6mm ) , Nut Bolts, 1No. Turn-Buckles, 1.8 M Long 16 Mm Diameter Solid Gi Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 117 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 118 Supply Of 6 Swg Gi Wire 119 Supply Of 8 Swg Gi Wire 120 Supply Of Conductor Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 121 Supply Of Pg Clamp For Weasel To Weasel Conductor 122 Supply Of Pg Clamp For Dog To Dog Conductor 123 Supply Of Pg Clamp For Rabbit To Rabbit Conductor 124 Installation Of Dt Capacitor 125 Supply Of Dt Capacitor With Fitting As Per Technical Specification, Approved Drawing And Scope Of Work 126 Supply Of Lt Shunt Capacitor 440 Volt 10 Kvar 3Phase 50Hz Ip65 127 Supply Of Lt Shunt Capacitor 440 Volt 16 Kvar 3Phase 50Hz Ip65 128 Supply Of Lt Shunt Capacitor 440 Volt 25 Kvar 3Phase 50Hz Ip65 129 Supply Of Lt Shunt Capacitor 440 Volt 40 Kvar 3Phase 50Hz Ip65 130 Supply Of Lt Shunt Capacitor 440 Volt 63 Kvar 3Phase 50Hz Ip65 131 Supply Of Lt Shunt Capacitor 440 Volt 100 Kvar 3Phase 50Hz Ip65 132 Erection Part 133 Installation Of Consumer Service Cable 134 Installation Of Armored Consumer Service Cable With Accessories Including Dismantling Of Existing Service Cable As Per Technical Specifications, Scope Of Works And Approved Drawings 135 Installation Of Single Phase Armored Al Cable Size 2Cx 6 Sq Mm 136 Installation Of Three Phase Armored Al Cable Size 4Cx 16 Sq Mm 137 Gi Wire 8 Swg 138 Gi Wire 10 Swg 139 Installation Of Gi Pipe / M.S Angle Along With Nails / Clamps / Proper Binding E.T.C. As Per R.E.C Std. 140 Erection For Conversion Of Existing Lt Lines On Bare Conductor To Aerial Bunch Xlpe Cable 141 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil Of Following Pole As Per Scope Of Work, Approved Drawings And Specifications: 142 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 143 Erection Of Following Types Of Poles For Lt Overhead Line With Stone Pad, Pole Numbering By Paint With Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 144 Erection Of 8.5 M / 180 Kgs Pcc Poles With Base Stone Pad As Required - ( State Practices Of Pcc Pole And Stone Pad To Be Used ) 145 Excavation Of Lt Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 146 Normal Soil 147 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator ( 1 No. ) And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 148 Removal Of Existing Lt Bare Line Conductor & Fixtures, Depositing To Stores Of Employer And Erection, Testing & Commissioning Of New Areal Bunched Xlpe Cable, Fixing Tension Clamps For Dead End, Suspension Clamps, Clamps For Neutral, Piercing Connectors Type-I & Type-Ii, Pre- Insulated Compression Connectors, 16 Mm Dia Ms Nuts & Bolts, Pole Clamps, Stainless Steel Strap, Single And Three Phase Pole Mounted Distribution Board, Energisation Of Distribution Box Through 2Cx25 Sqmm And 4Cx35 Sq.Mm Xlpe Cable Fixing End Cap Etc. As Required As Per Technical Specification, Approved Drawings And Scope Of Work: 149 Erection Of Aerial Bunched Xlpe Cable3 X 50 Sqmm +1X35 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 150 Erection Of Aerial Bunched Xlpe Cable 3 X 70 Sqmm +1X50 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 151 Erection Of Aerial Bunched Xlpe Cable 3 X 95 Sqmm +1X70 Sqmm ( Bare Messenger Cum Neutral ) + 1X16 Sqmm 152 Erection Of Aerial Bunched Xlpe Cable 3 X 120 Sqmm+ 1X95 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 153 Erection, Testing & Commissioning Of Earthing By Inserting Gi Earthing Spike Made Of 20Mm Solid Rod As Per Approved Drawings, Scope Of Work And Technical Specifications 154 Erection Of 8 Swg Gi Wire For Earthing By Providing Gi Nut, Bolts & Washers, Turn Buckle Etc As Per Approved Drawings, Scope Of Work And Technical Specifications 155 Erection, Testing And Commissioning Of New 11 Kv Lines: Feeder Segregation ( Agriculture Feeder ) 156 Survey, Route Alignment & Pole Spotting, Preparation Of Survey Report And Uploading In The Web Portal After Approval Of Project Manager 157 Excavation Of Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil For Following Type Pole As Per Scope Of Work, Approved Drawings And Specifications: 158 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 159 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 160 Erection Of Following Types Of Poles For 11 Kv Overhead Line By Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Painting With Red Oxide & Aluminum Paint To Stp Poles Including Paint, Numberingof Poleby Paint Including Cement Concrete Foundation Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 161 Erection Of 8.5 M / 180 Kgs Pcc Poles With Base Pad Including Cement Concreting, ( State Practices Of Pcc Pole, Stone To Be Used ) 162 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) - Cement Concreting 0.5 Cmt + 0.014 Cmt ( Muffing ) 163 Erection, Testing & Commissioning Of Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Channel, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures And Ms Nuts, Bolts & Washersas Per Technical Specification, Approved Drawings And Scope Of Work. 164 Earthing Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 165 Erection, Testing & Commissioning Of Spike Earthing 20Mm X 2500Mm Gi Solid Rod 166 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 167 Normal Soil 168 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 169 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 170 Erection Of 5 Kn 11 Kv Polymer With Pin Insulator 171 Erection Of 45 Kn 11 Kv Polymer Disc Insulator With Strain Hardware 172 Laying Out, Tensioning, Binding Of Conductor And Tightening Of Stays And Stringing, Testing And Commissioning Of Acsrconductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications 173 Stringing Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel 174 Erection, Testing And Commissioning Of Vertical Type 11 Kvab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete Asper Technical Specifications, Scope Of Works And Approved Drawings 175 Erection, Testing & Commissioning Of 11 Kv Line For Under Ground Railway Crossing By2 Nos ( Including One Spare ) 3Cx185 Sqmm Xlpe Armored Cable ( 0.3 Km Each ) , Using 150Mm Dia Gi Pipes, Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, 4 Nosgi 3-Meters Long Earthing Pipe, 6 Swg Gi Wires, Cable Markers, Clamps, Jumpering And 11 Kv Station Type Lightening Arrestors ( 6 Nos. ) , Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of He Work. 176 Erection, Testing & Commissioning Of 11 Kv Line For Under Ground Highway Crossing By2 Nos ( Including One Spare ) 3Cx185 Sqmm Xlpe Armored Cable ( 0.3 Km Each ) , Using 160 Mm Hdpe Pipe At Road Crossing, 150Mm Dia Gi Pipes For Cable Support, Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, 4 Nosgi 3-Meters Long Earthing Pipe, 6 Swg Gi Wires, 7 / 20 Gi Wire, Cable Markers, Clamps, Jumpering, 11 Kv Station Type Lightening Arrestors ( 6 Nos. ) , Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of He Work. 177 Erection Of 12 Kv, 1250 A, 25Ka For 3 Seconds, 3-Ph, Indoor Typevacuum Circuit Breaker With Adopter Panel For Out Going Feeder By Leveling, Alignment And Welding On Existing Cable Trench In Control Room. Testing & Commissioning Of Indoor Vcb Panel Including 3 Nos Indoor Type Current Transformer, A-Meter, Volt-Meter, Relay & Accessories Protection As Per Approved Drawings, Technical Specifications And Scope Of The Work.: 178 Providing And Fixing Of Sign Board Includingmaterial And Its Fabrication , Painting , Writing , Logo And Scheme Etc As Per Rdss Guidelines And T.S 179 Laying, Erection, Termination Using Indoor & Outdoor Termination Kit, 11Kv 3X 185 Sqmm Xlpearmored Power Cablesas Per Technical Specifications, Approved Drawings And Scope Of Works. : 180 Erection, Testing & Commissioning Of New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 181 Erection Of 6 Swg Gi Wire 182 Erection Of 8 Swg Gi Wire 183 Extension Of Control Room Of 33 / 11 Kv Substation To Accommodate Vcb For New 11 Kv Feeders As Per Technical Specification, Approved Drawing And Scope Of Work. 184 Design, Engineering Construction Of Control Room Building Extension 300 Sq Feet Including Cost Ofall Materials, T&P And Labour, Etc. As Per Technical Specification And Approved Drawing As Per Direction Of Employer 185 Shifting Of Following Distribution Transformer Along With Fixture Including Dismantling , Shifting And Erection From One Location To Another Location As Per Approved Survey. 186 Single Phase Transformer 187 Three Phase Transformer 188 Erection For Augmentation Of Lines 189 Erection For Augmentation Of 33 Kv Line 190 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 191 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 192 Erection Of Following Types Of Additional Poles Matching With Existing Line Supports By Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Painting With Red Oxide & Aluminum Paint Including Paint, Pole Numbering Including Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 193 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) - Cement Concreting 0.5 Cmt + 0.014 Cmt ( Muffing ) 194 Excavation Of Stay Pit For 33 Kv Stay In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 195 Normal Soil 196 Erection Of Complete Stay Set With Gi Stay Wire ( 7X4.00 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.3 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 197 Erection, Testing And Commissioning Of 33 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 198 Erection Of 33 Kv 10 Kn Pin Insulator With Gi Pin 199 Erection Of 33 Kv 70 Kn Disc Insulator With Strain Hardware ( Set Of 3, 11 Kv Disc Insulators ) 200 Erection, Testing & Commissioning Of New Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 201 Dismantling Of Existing Overhead Line Conductor And Fittings, Depositing The Dismantled Material To EmployerS Store And Laying Out & Stringing Of New Acsr Conductor Of Following Sizes By Providing Jointing Sleeves, Binding Wire & Tape & Helical Formed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 202 Stringing Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog Replacing Existing Racoon Conductor 203 Stringing Of 30 / 3.00 + 7 / 3.00 Mm ( 200 Mm² Al. Area ) - Panther Replacing Existing Dog / Racoon Conductor 204 Erection, Testing & Commissioning Of 33 Kvunder Ground Cable By2 Nos ( Including One Spare ) 3Cx300 Sqmm Xlpe Armored Cable, Using 160 Mm Hdpe Pipe At Road Crossing, 150Mm Dia Gi Pipes For Cable Support, Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, Cable Markers, Clamps, Jumpering, 7 / 20 Gi Wire Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of He Work. 205 Erection For Augmentation Of 3 Phase 33 Kv Line Using New Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work 206 Erection Of 33 Kv 70 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 207 Erection Of 33 Kv 10 Kn Polymer Pin Insulators 208 Erection, Testing & Commissioning Of Earthing As Per Technical Specifications, Approved Drawings And Scope Of Work. 209 8 Swg Gi Coil 115 Turns ( 1.85 Kg ) 210 Erection, Testing & Commissioning Of New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 211 Erection Of 6 Swg Gi Wire 212 Erection Of 8 Swg Gi Wire 213 Erection For Augmentation Of 11 Kv Lines 214 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 215 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 216 Erection Of Following Types Of Poles For 11 Kv Overhead Line By Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Pole Numbering Including Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 217 Erection Of 8.5 M / 180 Kgs Pcc Poles Withbase Stone Pad ( State Practices Of Pcc Pole And Base Plate / Stone To Be Used ) 218 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 219 Normal Soil 220 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 221 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 222 Erection Of 11 Kv Pin Insulator With Gi Pin 223 Erection Of 11 Kv Disc Insulator With Strain Hardware 224 Dismantling Of Existing Overhead Line Conductor & Fittings And Depositing To EmployerS Store, Laying Out, Tensioning, Binding Of New Conductor And Tightening Of Stays And Stringing, Testing And Commissioning Of Acsrconductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications 225 Stringing Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel By Replacing Existing Weasel / Squirrel Conductor 226 Stringing Of 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit By Replacing Existing Weasel / Squirrel Conductor 227 Stringing Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog By Replacing Existing Racoon / Rabbit Conductor 228 Erection, Testing & Commissioning Of Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Channel, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures And Hdg Ms Nuts, Bolts & Washers As Per Technical Specification, Approved Drawings And Scope Of Work. 229 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 230 Erection Of 5 Kn 11 Kv Polymer Pin Insulator 231 Erection Of 45 Kn 11 Kv Polymer Disc Insulator With Strain Hardware 232 Earthingand Guarding Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 233 Erection, Testing & Commissioning Of Spike Earthing 20Mm Solid Rod 234 Erection Of 8 Swg Gi Wire For Earthing And Guarding 235 Erection Of 6 Swg Gi Wire For Earthing And Guarding 236 Erection Of Dt Capacitor 237 Erection, Testing & Commissioning Offollowing 440 Volt Lt Shunt Capacitor Including Mounting Structure And Accessories As Required As Per Technical Specifications, Approved Drawings And Scope Of Work. 238 Erection Of Lt Shunt Capacitor 440 Volt 10 Kvar 3Phase 50Hz Ip65 239 Erection Of Lt Shunt Capacitor 440 Volt 16 Kvar 3Phase 50Hz Ip65 240 Erection Of Lt Shunt Capacitor 440 Volt 25 Kvar 3Phase 50Hz Ip65 241 Erection Of Lt Shunt Capacitor 440 Volt 40 Kvar 3Phase 50Hz Ip65 242 Erection Of Lt Shunt Capacitor 440 Volt 63 Kvar 3Phase 50Hz Ip65 243 Erection Of Lt Shunt Capacitor 440 Volt 100 Kvar 3Phase 50Hz Ip65 244 Discount Offered In % 245 Words Final Quoted Price After Discount

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Aug-2022 Time Extention Date 31-08-2022

Key Value

Document Fees
INR 29500 /-
EMD
INR 50000000.0 /-
Tender Value
INR 684.84 Crore /-

BOQ Items

Name of Work: DEVELOPMENT OF DISTRIBUTION INFRASTRUCTURE OF PACKAGEPRAYAGRAJ 1 AT PRAYAGRAJ DISTRICT OF PuVVNLUTTAR PRADESHUNDERREVAMPED REFORMS-BASED AND RESULTS-LINKED, DISTRIBUTION SECTOR SCHEME
Sl. No. Item Description
1Supply of Consumer Service Cable
2Supply of Armored service cable for consumer service connection with accessories as per technical specifications, scope of works and approved drawings
3Supply of Single Phase armored AL cable size 2CX 6 Sq mm
4Supply of Three Phase armored AL cable size 4CX 16 Sq mm
5Supply of 10 SWG GI wire
6Supply of 8 SWG GI wire
7Supply of GI Pipe/M.S Angle along with Nails/Clamps/Proper Binding e.t.c. as per REC Std.
8Conversion of existing LT lines on bare conductor to Areal bunch XLPE cable
9Conversion of existing LT lines with bare conductor to AB XLPE cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings
10Supply of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice)
11Galvanized Stay Set for LT line with anchor plate (200x200x6mm), 50x8mm stay clamp, 1 no. Stay guy insulator, nut bolts, 1 no. turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work.
12Conversion of existing LT lines using new Earthing as per approved drawings, technical specifications and scope of work
13Supply of Spike Earthing made of 20mm X 2500 mm GI solid Rod
14Supply of 8 SWG GI wire for earthing and guarding
15Supply of following LT AB XLPE Cable for Conversion of existing LT bare conductor line with AB XLPE Cable as required as per technical specification, approved drawings and scope of work:
16Supply of Aerial bunchedXLPE cable 3 X 50 sqmm+1x35 sqmm.(bare messenger wire)+1x16 sqmm.
17Supply of Aerial bunchedXLPE cable 3 X 70 sqmm.+1x50 sqmm.(Bare messenger wire)+1x16 sqmm.
18Supply of Aerial bunchedXLPE cable 3 X 95 sqmm.+1x70 sqmm.( bare messenger wire)+ 1x16 sqmm.
19Supply of Aerial bunchedXLPE cable 3 X 120 sqmm. + 1x95 sqmm.(bare messenger wire) +1x16 sqmm.
20Supply of Pole mounted LT Distribution box as per approved drawings, technical specifications and scope of work
21Supply of Three phase SMC Distribution box with clamps
22Supply of Single phase SMC Distribution box with clamps
23Supply of XLPE insulated Al. cable for energisation of distribution box/ Kiosk as per approved drawings, technical specifications and scope of work
24Suppply of 2Cx25 SQMM Stranded Unarmoured Cable (Al Conductor ) for chargingSingle Phase DB
25Suppply of 4Cx35SQMM Stranded Unarmoured Cable (Al Conductor ) for chargingThreePhase DB
26Supply of Stone pad (300x300x75)
27Supply of Accessories for AB XLPE Cable as per approved drawings, technical specifications and scope of work
28Stainless steel Strap
29HDG LT Pole Clamp with nut & bolt for laying ABC
30Dead end Clamp with I-Hook( Insulated)
31Suspension Clamp with I-Hook ( Insulated)
3295/35 Sqmm - 70/25 sqmm PG Clamps( for line to line jumpering & energizing DB neutral)
33120/50 Sqmm - 95/25 sqmm PG Clamps( for line to line jumpering & energizing DB neutral)
34LT Insulation piercing connector 120-50 sqmm - 50-25 sqmm size (for energizing distribution box)
35LT Insulation piercing connector 120-50 sqmm - 120-50 sqmm size (for line to line jumpering)
36LT Insulation piercing connector 16 - 25sqmmsize suitable for street light connection
37Pre-Insulated Compression connectors size 16 sqmm suitable for AB XLPE cable
38Pre-Insulated Compression connectors size 50 sqmm suitable for AB XLPE cable
39Pre-Insulated Compression connectors size 70 sqmm suitable for AB XLPE cable
40Pre-Insulated Compression connectors size 95 sqmm suitable for AB XLPE cable
41Pre-Insulated Compression connectors size 120 sqmm suitable for AB XLPE cable
42Heat shrinkable type end cap for AB XLPE cable
43Supply of New 11 KV Lines : feeder Segregation ( Agriculture Feeder)
44Supply of Support for 11 KV overhead line as per technical specification, approved drawings and scope of work
45Supply of 8.5m/180 kgs PCC Poles - (PCC Pole as per state practice)
46Supply of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
47Supply for 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, Bracket, Clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS transformer base channel, MS flats pole extension channel with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
48Supply of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
49Supply of Pole accessories as per technical specification, approved drawing and scope of work
50Supply of 11 KV danger board
51Supply of Stone Pad 300X300X75
52Supply of Barbed GI wire 12 SWG
53Supply of Stay Set (Galvanized) with 50x8 mm stay clamp, stay guy insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
54Supply of Insulator and hardware as per technical specification, approved drawings and scope of work.
55Supply of 11 KV45 KN polymer Disc insulator along with suitable hardware fittings
56Supply of 11 KV 5 KN Polymer with Pin Insulators
57Supply of Earthing arrangement as per technical specifications,approved drawings and scope of work.
58Supply of Spike Earthing 20mm X 2500 mm GI solidRod
59Supply of 8 SWG GI wire for earthing and guarding
60Supply of 6 SWG GI wire for earthing and guarding
61Supply of ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
62Supply of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
63Supply of 11 kV, 600A,3-ph, 3 Pin type, Vertical Mounting type, Gang Operated,AB Switch along with Support Insulators, Base Channel down Pipe, Arcing Horns etc. complete asper technical specifications, scope of works and approved drawings
64Supply of 11 KV Lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work
65Supply for 11 KV lineunder ground Railway crossing with 2 nos (Including one spare) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) using 150mm dia GI pipes (grade A for underground laying and grade B for pole support), Outdoor heat shrinkable cable jointing kit, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, 4 Nos GI 3-Meters LONG pipe EARTHING, 6 SWG GI WIRES,CABLE MARKERS, BI METALLICK CLAMPS and JUMPERING etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK.
66Supply of 11 LV Line underground Highway crossing ensuring statutory clearancesas required as per technical specification, approved drawings and scope of work
67Supply of 11 KV LINEFORUNDER GROUND Highway CROSSING BY 2 Nos (INCLUDING ONE SPARE) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) USING 160 mm HDPE pipe at road crossing and 150MM DIA GI PIPES (gradeB for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, 4 Nos GI 3-Meters LONG pipe EARTHING, 6 SWG GI WIRES, 7/20 GI wire, CABLE MARKERS, BI METALLICK CLAMPS and JUMPERING etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK.
68Supply of 12 KV 3ph Indoor type switch gear and 11 KV XLPE cable as per technical specifications, approved drawings and scope of works:
69Supply of Indoor type 12 KV 3 Ph 1250 A VCB with control and protection system for out going feeder consisting ofCT, A-meter, volt-meter, Relays, energy meter (TVM) DLMS compliant & accessories complete as per specifications for feeder breaker
7011 KV 3X 185 sqmm XLPE armored Power cable, aluminum stranded conductor, including their termination materials like indoor and outdoor termination kit, glands, lugs, tagging, cable path marker etc as required as per technical specifications, approved drawings and scope of the works.
71Supply for Augmentation of lines
72Supply for Augmentation of 33 KV Line
73Supply for Augmentation of 3 phase 33 kV line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings
74Supply of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
75Supply New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
76Supply of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
77Supply of Pole accessories as per technical specification, approved drawing and scope of work
78Supply of 33 KV danger board
79Supply of GI Barbed wire 12 SWG
80Supply for Augmentation of 3 phase 33 kV line replacing existing conductor with following type of new ACSR conductor including jointing sleeves, binding material, aluminum tape and helical Preformed fittings etc as required as per technical specification, approved drawings and scope of work.
81Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog replacing existing racoon conductor
82Supply of 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther replacing existing dog/racoon conductor
83Supply of 33 KV Under ground cable as per technical specification, approved drawings and scope of work.
84Supply of 3CX300 Sqmm 33 KV XLPE Armored Cable
85Supply of 33 KV3Cx300 Sqmm XLPE Armored Cable (2 Nos including one spare) Accessories like 160mm dia HDPE pipes for road crossing and 150 mm dia GI pipegrade B for pole support outdoor heat shrinkable cable jointing kits, Lugs,CablePath markers, bi metallic clamps, 7/20 GI wire as per technical specification, approved drawing and scope of work
86Supplyof new Insulator and hardware for Augmentation of33 kV line as per technical specification, approved drawings and scope of work
87Supply of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings
88Supply of 33 KV 10 KN Polymer Pin Insulators
89Supply of new Earthing arrangement for Augmentation of33 kV line as per technical specifications,approved drawings and scope of work.
908 SWG GI Coil 115 turns (1.85 kg)
91Supply of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate (300x300x8mm) , nut bolts, 1 no. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
92Supply of new GI wire for earthing and guarding for Augmentation of33 kV line as per technical specification, approved drawings and scope of work.
93Supply of 6 SWG GI wire
94Supply of 8 SWG GI wire
95Supply of Conductor accessories as per technical specification, approved drawing and scope of work
96Supply of PG Clamp for Dog to Dog conductor
97Supply of PG Clamp for Panther to Panther conductor
98Supply for Augmentation of 11 KV lines
99Supply for Augmentation of 3 phase 11 kV line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings
100Supply of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice)
101Supply for Augmentation of 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
102Supply of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
103Supply of Pole accessories as per technical specification, approved drawing and scope of work
104Supply of 11 KV danger board
105Stone Pad(300x300x75mm)
106Supply of GI Barbed wire 12 SWG
107Supply for Augmentation of 3 phase 11 kV line replacing existing conductor with following type of new ACSR conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work.
108Supply of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel by replacing existing weasel/squirrel conductor
109Supply of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor
110Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor
111Supply for Augmentation of 3 phase 11 kV line using new Insulator and hardware as per technical specification, approved drawings and scope of work
112Supply of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings
113Supply of 11 KV 5 KN Polymer Pin Insulators
114Supply for Augmentation of 3 phase 11 kV line using new Earthing arrangement as per technical specifications,approved drawings and scope of work.
115Supply of GI Earthing spike made of 20x2500mmsolid Rod
116Supply for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
117Supply for Augmentation of 3 phase 11 kV line using new GI wire for earthing and guarding as per technical specification, approved drawings and scope of work.
118Supply of 6 SWG GI wire
119Supply of 8 SWG GI wire
120Supply of Conductor accessories as per technical specification, approved drawing and scope of work
121Supply of PG Clamp for Weasel to Weasel conductor
122Supply of PG Clamp for Dog to Dog conductor
123Supply of PG Clamp for Rabbit to Rabbit conductor
124Installation of DT Capacitor
125Supply of DT Capacitor with Fitting as per Technical Specification, Approved Drawing and scope of work
126Supply of LT Shunt capacitor 440 Volt 10 KVAr 3Phase 50Hz IP65
127Supply of LT Shunt capacitor 440 Volt 16 KVAr 3Phase 50Hz IP65
128Supply of LT Shunt capacitor 440 Volt 25 KVAr 3Phase 50Hz IP65
129Supply of LT Shunt capacitor 440 Volt 40 KVAr 3Phase 50Hz IP65
130Supply of LT Shunt capacitor 440 Volt 63 KVAr 3Phase 50Hz IP65
131Supply of LT Shunt capacitor 440 Volt 100 KVAr 3Phase 50Hz IP65
132Erection Part
133Installation of Consumer Service Cable
134Installation of Armored consumer service cable with accessories including dismantling of existing service cable as per technical specifications, scope of works and approved drawings
135Installation of Single Phase armored AL cable size 2CX 6 Sq mm
136Installation of Three Phase armored AL cable size 4CX 16 Sq mm
137GI Wire 8 SWG
138GI Wire 10 SWG
139Installation of GI Pipe/M.S Angle along with Nails/Clamps/Proper Binding e.t.c. as per R.E.C Std.
140Erection for Conversion of existing LT lines on bare conductor to Aerial bunch XLPE cable
141Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil of following pole as per scope of work, approved drawings and specifications:
1428.5 m/180 kgs PCC Poles - (PCC Pole as per state practice)
143Erection of following types of poles for LT overhead line with Stone pad, pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications:
144Erection of 8.5 m/180 Kgs PCC Poles with base stone Pad as required - (state practices of PCC pole and stone Pad to be used)
145Excavation of LT stay pit in following type of soils,as per scope of work, approved drawings and specifications:
146Normal soil
147Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 no.) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
148Removal of existing LT bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched XLPE cable, Fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type-I & type-II, Pre- insulated compression connectors, 16 mm dia MS nuts & bolts, pole clamps, stainless steel strap, Single and three phase pole mounted distribution board, energisation of distribution box through 2Cx25 sqmm anD 4Cx35 sq.mm XLPE cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work:
149Erection of Aerial Bunched XLPE Cable3 X 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm
150Erection of Aerial Bunched XLPE Cable 3 X 70 sqmm +1x50 sqmm ( bare messenger cum neutral )+1x16 sqmm
151Erection of Aerial Bunched XLPE Cable 3 X 95 sqmm +1x70 sqmm ( bare messenger cum neutral )+ 1x16 sqmm
152Erection of Aerial Bunched XLPE Cable 3 X 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm
153Erection, testing & commissioning of earthing by inserting GI Earthing spike made of 20mm solid Rod as per approved drawings, scope of work and technical specifications
154Erection of 8 SWG GI wire for earthing by providing GI nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications
155Erection, testing and Commissioning of New 11 KV lines: Feeder Segregation (Agriculture Feeder)
156Survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of Project Manager
157Excavation of pole pit (of depth 1/6th of pole length) in normal soil for following type pole as per scope of work, approved drawings and specifications:
1588.5 m/180 kgs PCC Poles - (PCC Pole as per state practice)
15911 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
160Erection of following types of poles for 11 KV overhead line by installing danger plate, anti-climbing devices (barbed wire), Painting with red oxide & aluminum paint to STP poles including paint, numberingof poleby paint including cement concrete foundation using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4)etc as per scope of work, approved drawings and specifications:
161Erection of 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used)
16211 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
163Erection, testing & commissioning of pre-fabricated HDG steel items like V cross arm, top channel,top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures and MS nuts, bolts & washersas per technical specification, approved drawings and scope of work.
164Earthing arrangement as per technical specifications,approved drawings and scope of work.
165Erection, testing & commissioning of Spike Earthing 20mm x 2500mm GI solid Rod
166Excavation of stay pit in following type of soils,as per scope of work, approved drawings and specifications:
167Normal soil
168Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
169Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.
170Erection of 5 KN 11 kV Polymer with Pin insulator
171Erection of 45 KN 11 kV Polymer Disc insulator with strain hardware
172Laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of ACSRConductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications
173Stringing of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
174Erection, Testing and Commissioning of vertical type 11 kVAB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete asper technical specifications, scope of works and approved drawings
175Erection, testing & commissioning of 11 KV line for under ground railway crossing by2 Nos (including one spare) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) , using 150MM dia GI pipes, outdoor heat shrinkable cable jointing kits, lugs,4 NosGI 3-meters long earthing pipe, 6 SWG GI wires, cable markers, clamps, jumpering and 11 KV station type lightening arrestors(6 NOS.), etc as required as per technical specifications, approved drawings and scope of he work.
176Erection, testing & commissioning of 11 KV line for under ground highway crossing by2 Nos (including one spare) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) , using 160 mm HDPE pipe at road crossing, 150MM dia GI pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs,4 NosGI 3-meters long earthing pipe, 6 SWG GI wires, 7/20 GI wire, cable markers, clamps, jumpering, 11 KV station type lightening arrestors(6 NOS.), etc as required as per technical specifications, approved drawings and scope of he work.
177Erection of 12 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor typeVacuum Circuit breaker with adopter panel for out going feeder by leveling, alignment and welding on existing cable trench in control room. Testing & commissioning of indoor VCB panel including 3 Nos indoor type Current Transformer,A-meter, volt-meter, Relay & accessories protection as per approved drawings, technical specifications and scope of the work.:
178Providing and fixing of Sign Board IncludingMaterial and its Fabrication ,Painting ,Writing ,Logo and Scheme etc as Per RDSS Guidelines and T.S
179Laying, erection, termination using indoor & outdoor termination kit, 11KV 3x 185 sqmm XLPEarmored Power cablesas per technical specifications, approved drawings and scope of works. :
180Erection, testing & commissioning of new GI wire for earthing and guarding as per technical specification, approved drawings and scope of work.
181Erection of 6 SWG GI wire
182Erection of 8 SWG GI wire
183Extension of Control room of 33/11 KV Substation to accommodate VCB for new 11 KV feeders as per technical specification, approved drawing and scope of work.
184Design, Engineering construction of Control room building extension 300 Sq feet including cost ofall materials, T&P and Labour,etc. as per Technical specification and approved drawing as per direction of Employer
185Shifting of following Distribution Transformer along with fixture including dismantling , shifting and erection from one location to another location as per approved survey.
186Single Phase Transformer
187Three Phase Transformer
188Erection for Augmentation of lines
189Erection for Augmentation of 33 KV Line
190Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil as per scope of work, approved drawings and specifications:
19111 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
192Erection of following types of additional poles matching with existing line supports by installing danger plate, anti-climbing devices (barbed wire), Painting with red oxide & aluminum paint including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications:
19311 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
194Excavation of stay pit for 33 KV Stay in following type of soils,as per scope of work, approved drawings and specifications:
195Normal soil
196Erection of complete stay set with GI stay wire (7x4.00 mm dia), binding of stay wire, by providing Guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
197Erection, testing and commissioning of 33 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.
198Erection of 33 kV 10 KN Pin insulator with GI pin
199Erection of 33 kV 70 KN Disc insulator with strain hardware (set of 3, 11 KV disc insulators)
200Erection, testing & commissioning of new Pre-fabricated HDG steel items like V cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures as per technical specification, approved drawings and scope of work.
201Dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employer"s store and laying out & stringing of new ACSR conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work.
202Stringing of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog replacing existing racoon conductor
203Stringing of 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther replacing existing dog/racoon conductor
204Erection, testing & commissioning of 33 KVunder ground Cable by2 Nos (including one spare) 3Cx300 Sqmm XLPE Armored Cable, using 160 mm HDPE pipe at road crossing, 150mm dia GI pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering, 7/20 GI wire etc as required as per technical specifications, approved drawings and scope of he work.
205Erection for Augmentation of 3 phase 33 kV line using new Insulator and hardware as per technical specification, approved drawings and scope of work
206Erection of 33 KV 70 KN polymer Disc insulator along with suitable hardware fittings
207Erection of 33 KV 10 KN Polymer Pin Insulators
208Erection, testing & commissioning of earthing as per technical specifications,approved drawings and scope of work.
2098 SWG GI Coil 115 turns (1.85 kg)
210Erection, testing & commissioning of new GI wire for earthing and guarding as per technical specification, approved drawings and scope of work.
211Erection of 6 SWG GI wire
212Erection of 8 SWG GI wire
213Erection for Augmentation of 11 KV lines
214Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil as per scope of work, approved drawings and specifications:
2158.5 m/180 kgs PCC Poles - (PCC Pole as per state practice)
216Erection of following types of poles for 11 KV overhead line by installing danger plate, anti-climbing devices (barbed wire),pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications:
217Erection of 8.5 m/180 Kgs PCC Poles withBase stone pad(state practices of PCC pole and base plate/stone to be used)
218Excavation of stay pit in following type of soils,as per scope of work, approved drawings and specifications:
219Normal soil
220Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
221Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.
222Erection of 11 kV Pin insulator with GI pin
223Erection of 11 kV Disc insulator with strain hardware
224Dismantling of existing overhead line conductor & fittings and depositing to Employer"s store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of ACSRConductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications
225Stringing of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel by replacing existing weasel/squirrel conductor
226Stringing of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor
227Stringing of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor
228Erection, testing & commissioning of pre-fabricated HDG steel items like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures and HDG MS nuts, bolts & washers as per technical specification, approved drawings and scope of work.
229Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.
230Erection of 5 KN 11 kV Polymer Pin insulator
231Erection of 45 KN 11 kV Polymer Disc insulator with strain hardware
232Earthingand guarding arrangement as per technical specifications,approved drawings and scope of work.
233Erection, testing & commissioning of Spike Earthing 20mm solid Rod
234Erection of 8 SWG GI wire for earthing and guarding
235Erection of 6 SWG GI wire for earthing and guarding
236Erection of DT Capacitor
237Erection, Testing & Commissioning offollowing 440 Volt LT shunt Capacitor including mounting Structure and accessories as required as per technical specifications,approved drawings and scope of work.
238Erection of LT Shunt capacitor 440 Volt 10 KVAr 3Phase 50Hz IP65
239Erection of LT Shunt capacitor 440 Volt 16 KVAr 3Phase 50Hz IP65
240Erection of LT Shunt capacitor 440 Volt 25 KVAr 3Phase 50Hz IP65
241Erection of LT Shunt capacitor 440 Volt 40 KVAr 3Phase 50Hz IP65
242Erection of LT Shunt capacitor 440 Volt 63 KVAr 3Phase 50Hz IP65
243Erection of LT Shunt capacitor 440 Volt 100 KVAr 3Phase 50Hz IP65
244Discount offered in %
245Words Final Quoted Price after Discount
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail