Jawaharlal Nehru Port Trust-JNPT has published Quotation For Upgradation Of Existing Sports Facilities And Construction Of New Facilities At Jnp Township. Submission Date for this Tender is 17-08-2022. Civil Work Tenders in Raigad Maharashtra. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply, installation, testing & commissioning of 12 Port PoE+ Switch with 2 SFP slots 12 x 10/100/1000 Base-T PoE+ ports and additional 2 100/1000X SFP PORTS Should support PoE+ as per IEEE 802.3 at with PoE budget of 100W.Should support STP, RSTP, MSTP, IGMP v1/v2/v3 snooping, STP root guard, Voice VLAN, MLD snooping (MLDv1 and v2), IEEE 802.3ac VLAN tagging IEEE 802.17/equivalent for sub 50ms ring protection in following scenario : single, dual fibre cuts in ring and when fibre cut at common shared link in between two or more rings. |
2 | Supply, Installation, Testing and Commissioning of 4 TB Internal Surveillance Hard Disk for recording. |
3 | Network Wiring for Cameras/devices with CAT 6e cable from NVR in exposed / recessed 25 mm dia MS Conduit including termination and providing/fixing 1.2 mm thick GI box with grid plates with earthing complete in all respect. |
4 | Power wiring for Cameras/devices with 3 x 1.5 sq mm FRLS wire in exposed / recessed 25 mm dia MS Conduit including termination and providing/fixing 1.2 mm thick GI box with grid plates with earthing complete in all respect. |
5 | Design, manufacture, supply,including supervision during installation, testing and commissioningof 2 mm thick MS sheet steel fabricated cubicle type Panel dust and verminproof complete with hinged and lockable doors .The Sheet Steel shall under go minimum eight tank treatment followed by finishing treatment of powder coating with 70 micron minimum thickness. All the panels shall be floor mounted and dead front construction complete with interconnections. |
6 | Note:- |
7 | The panels shall beFRONT operated, with cable entry from the top.Earth bus shall be part of the panel.) (All MCB to be "C" Curve) |
8 | The following provisions shall be required to be made in the Distribution Panel as detailed below: |
9 | All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB door handle shall be interlocked and lockable in OFF position. |
10 | Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards. |
11 | Suitable Aluminium earth bus to be provided throughout the length of Switchboards. |
12 | All indication lamps / illuminated push buttons shall be LED type. |
13 | Coil of all motor starters shall be fed from 440 V / 230 V Control Transformer. |
14 | 2A SP MCBs shall be used as backup protections. |
15 | All MCCBs shall be variable plug setting type with thermal magnetic up to 630 A rating and with microprocessor based releases above 630 A rating, line load reversibility, Ics = 100% Icu,& rotary handle. |
16 | All control& power wiring shall be broughtout upto the cable alley in the terminal blocks. |
17 | An approval shall be taken for each panel before manufacturing. |
18 | Provision of one 6/16 amp socket & compartment lighting for each vertical section of main panel. |
19 | Illuminated push button on Starter Panels of Pumps. |
20 | Interlocking / Auto start command terminals for starter Panels. |
21 | All breaking Capacity for ACB to be Ics=100%Icu and Icw for 1 sec.. |
22 | All breaking Capacity for MCCB to beIcs=100%Icu. |
23 | All MCB to be C Curve |
24 | Pavilion Panel |
25 | Incoming: |
26 | 1 no. of 100Amp FPMCCB of 16 KA breaking capacity &Trip setting as required. |
27 | Metering for incoming: |
28 | Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement ofPF, V, A & Hz , equivalent to EM6459, with CT as required. |
29 | Phase indicating lamps RYBwith 6 Amps SP MCB back up. |
30 | Bus Bars: |
31 | Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement ofPF, V, A & Hz , equivalent to EM6459, with CT as required. |
32 | Phase indicating lamps RYBwith 6 Amps SP MCB back up. |
33 | Electrolytic high conductivity Aluminium three phase and neutral busbars rated at 150 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.3 sq.mm / amp. |
34 | Laying and Jointing PVC Pipe. Heading |
35 | Brick work in C.M 1:5 mix including all labour charges etc complete |
36 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost and conveyance of all materials and including all labour charges etc complete |
37 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and including all labour charges etc complete |
38 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and in |
39 | b)CI bend 22.5° (250mm dia) |
40 | Construction of chamber for 100mm sluice plates |
41 | Construction of chamber for 100mm sluices valve |
42 | Supplying, Conveying and fixing spls. Including ea |
43 | Supplying, Conveying and fixing spls. Including eart |
44 | Construction of chamber for 100mm sluice plates |
45 | Construction of chamber for 100mm sluices valve |
46 | Laying and Jointing PVC Pipe. Heading |
47 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using |
48 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost |
49 | Construction of chamber for 100mm sluices valve |
50 | The Total value of Schedule1 |
51 | Outgoing (All MCB/MCCB shall be suitable for motor duty): |
52 | 3 Nos. 63A FP MCB of 10 KA breaking capacity. |
53 | 2 Nos. 63A DP MCB of 10 KA breaking capacity. |
54 | Pavilion Panelas described above shall be complete with all interconnections, risers, internal wiring, labels, terminal blocks etc. complete as required. |
55 | KIT/ELE |
56 | Supply, installation, testing & commissioning of 12 Port PoE+ Switch with 2 SFP slots 12 x 10/100/1000 Base-T PoE+ ports and additional 2 100/1000X SFP PORTS Should support PoE+ as per IEEE 802.3 at with PoE budget of 100W.Should support STP, RSTP, MSTP, IGMP v1/v2/v3 snooping, STP root guard, Voice VLAN, MLD snooping (MLDv1 and v2), IEEE 802.3ac VLAN tagging IEEE 802.17/equivalent for sub 50ms ring protection in following scenario : single, dual fibre cuts in ring and when fibre cut at common shared link in between two or more rings. |
57 | Supply, Installation, Testing and Commissioning of 4 TB Internal Surveillance Hard Disk for recording. |
58 | Network Wiring for Cameras/devices with CAT 6e cable from NVR in exposed / recessed 25 mm dia MS Conduit including termination and providing/fixing 1.2 mm thick GI box with grid plates with earthing complete in all respect. |
59 | Power wiring for Cameras/devices with 3 x 1.5 sq mm FRLS wire in exposed / recessed 25 mm dia MS Conduit including termination and providing/fixing 1.2 mm thick GI box with grid plates with earthing complete in all respect. |
60 | Design, manufacture, supply,including supervision during installation, testing and commissioningof 2 mm thick MS sheet steel fabricated cubicle type Panel dust and verminproof complete with hinged and lockable doors .The Sheet Steel shall under go minimum eight tank treatment followed by finishing treatment of powder coating with 70 micron minimum thickness. All the panels shall be floor mounted and dead front construction complete with interconnections. (Form IIIB) |
61 | Note:- |
62 | The panels shall beFRONT operated, with cable entry from the top.Earth bus shall be part of the panel.) (All MCB to be "C" Curve) |
63 | The following provisions shall be required to be made in the Distribution Panel as detailed below: |
64 | All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB door handle shall be interlocked and lockable in OFF position. |
65 | Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards. |
66 | Suitable Aluminium earth bus to be provided throughout the length of Switchboards. |
67 | All indication lamps / illuminated push buttons shall be LED type. |
68 | Coil of all motor starters shall be fed from 440 V / 230 V Control Transformer. |
69 | 2A SP MCBs shall be used as backup protections. |
70 | All MCCBs shall be variable plug setting type with thermal magnetic up to 630 A rating and with microprocessor based releases above 630 A rating, line load reversibility, Ics = 100% Icu,& rotary handle. |
71 | All control& power wiring shall be broughtout upto the cable alley in the terminal blocks. |
72 | An approval shall be taken for each panel before manufacturing. |
73 | Provision of one 6/16 amp socket & compartment lighting for each vertical section of main panel. |
74 | Illuminated push button on Starter Panels of Pumps. |
75 | Interlocking / Auto start command terminals for starter Panels. |
76 | All breaking Capacity for ACB to be Ics=100%Icu and Icw for 1 sec.. |
77 | All breaking Capacity for MCCB to beIcs=100%Icu. |
78 | All MCB to be C Curve |
79 | Kitchen Panel |
80 | Incoming: |
81 | 1 no. of 100Amp FPMCCB of 16 KA breaking capacity &Trip setting as required. |
82 | Metering for incoming: |
83 | Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement ofPF, V, A & Hz , equivalent to EM6459, with CT as required. |
84 | Phase indicating lamps RYBwith 6 Amps SP MCB back up. |
85 | Bus Bars: |
86 | Electrolytic high conductivity Aluminium three phase and neutral busbars rated at 150 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.3 sq.mm / amp. |
87 | Outgoing (All MCB/MCCB shall be suitable for motor duty): |
88 | 5 Nos. 63A FP MCB of 10 KA breaking capacity. |
89 | 2 Nos. 63A DP MCB of 10 KA breaking capacity. |
90 | Kitchen Panelas described above shall be complete with all interconnections, risers, internal wiring, labels, terminal blocks etc. complete as required. |
91 | TOI/ELE |
92 | Supply, installation, testing & commissioning of 12 Port PoE+ Switch with 2 SFP slots 12 x 10/100/1000 Base-T PoE+ ports and additional 2 100/1000X SFP PORTS Should support PoE+ as per IEEE 802.3 at with PoE budget of 100W.Should support STP, RSTP, MSTP, IGMP v1/v2/v3 snooping, STP root guard, Voice VLAN, MLD snooping (MLDv1 and v2), IEEE 802.3ac VLAN tagging IEEE 802.17/equivalent for sub 50ms ring protection in following scenario : single, dual fibre cuts in ring and when fibre cut at common shared link in between two or more rings. |
93 | Network Wiring for Cameras/devices with CAT 6e cable from NVR in exposed / recessed 25 mm dia MS Conduit including termination and providing/fixing 1.2 mm thick GI box with grid plates with earthing complete in all respect. |
94 | Power wiring for Cameras/devices with 3 x 1.5 sq mm FRLS wire in exposed / recessed 25 mm dia MS Conduit including termination and providing/fixing 1.2 mm thick GI box with grid plates with earthing complete in all respect. |
95 | GYM/PLM |
96 | Providing and fixing of precast RCC perforated drain cover of size 600 mm X 600 mm X 75 mm. With M- 30 Grade of concrete and reinforcement 8 mm steel @ 100 mm C/C. For easy flow of water. |
97 | PBC/FF |
98 | Providing and fixing doorwith frame for all internal fire hydrants fabricated from 20x20x3mm and40x20x3 mm aluminium hollow box sections mounted with 3 no. of 100 mm Aluminium butt hinge onAluminium angle frame of 45x45x5mm size with hold fasts fixed to wallwithP.C.C. (1:2:4) blocks 100x100x100 mm including 2 nos allen key lock for locking along with padlock arrangement& fully glazed with 4 mm thick float glass approved by local Fire Authority, powder coated fire red finish with " fire hose" written on front suitable to house 15 mm long two length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. Size 1200x 600 mm complete as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.) |
99 | Float type Sensor with panel and installation |
100 | For electric driven terrace pump suitable forautomatic operationandconsistingoffollowing,completeinall respects, as required: (Terrace Pump) |
101 | (a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 |
102 | b)SuitableHPsquirellcageinductionmotorTEFCtype suitable for operation on 415 volts, 3 phase, 50 Hz, AC supplywithIP55classofprotectionforenclosure, horiziontalfootmountedtypewithClass-"F"insulation,conforming to IS-325. |
103 | (c)M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc. |
104 | For electric driven terrace pump suitable forautomatic operationandconsistingoffollowing,completeinall |
105 | (d)Suitablecementconcretefoundationdulyplastered and with anti vibration pads. |
106 | 450 lpm at 35 m Head |
107 | Forliquidlevel controller for fire pumpto stop fire pump in caseoflow level of water in tank. |
108 | Providing and fixing rubber expansion joint (to provide relief from stresses at pipe flanges)as per specification of the manufacturers and direction of Engineer in chief PN-16 rating |
109 | 100 mm dia |
110 | 150 mm dia |
111 | KIT/FF |
112 | Providing and fixing doorwith frame for all internal fire hydrants fabricated from 20x20x3mm and40x20x3 mm aluminium hollow box sections mounted with 3 no. of 100 mm Aluminium butt hinge onAluminium angle frame of 45x45x5mm size with hold fasts fixed to wallwithP.C.C. (1:2:4) blocks 100x100x100 mm including 2 nos allen key lock for locking along with padlock arrangement& fully glazed with 4 mm thick float glass approved by local Fire Authority, powder coated fire red finish with " fire hose" written on front suitable to house 15 mm long two length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. Size 1200x 600 mm complete as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.) |
113 | Float type Sensor with panel and installation |
114 | For electric driven terrace pump suitable forautomatic operationandconsistingoffollowing,completeinall respects, as required: (Terrace Pump) |
115 | (a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 |
116 | b)SuitableHPsquirellcageinductionmotorTEFCtype suitable for operation on 415 volts, 3 phase, 50 Hz, AC supplywithIP55classofprotectionforenclosure, horiziontalfootmountedtypewithClass-"F"insulation,conforming to IS-325. |
117 | (c)M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. |
118 | For electric driven terrace pump suitable forautomatic operationandconsistingoffollowing,completeinall |
119 | (d)Suitablecementconcretefoundationdulyplastered and with anti vibration pads. 450 lpm at 35 m Head |
120 | For liquidlevel controller for fire pumpto stop fire pump in caseoflow level of water in tank. |
121 | Providing and fixing rubber expansion joint (to provide relief from stresses at pipe flanges)as per specification of the manufacturers and direction of Engineer in chief PN-16 rating |
122 | 100 mm dia |
123 | 150 mm dia |
124 | GYM/EQP |
125 | HS-510 Air Space Walker Double Specification- 1.Main frame 114mm. B class(3mm to 3.5mm. thickness) 2. Swinging paddle pipe 50mm. B class(3mm to 3.5mm. thickness) 3. Handle Pipe 30mm. B class(3mm to 3.5mm. thickness) 4. Permanent lubricated sealed bearing of reputed brand. 5. Nuts & Bolts Galvanized. 6. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj) |
126 | HS-513 Leg Press Specification- 1. Center main pipe114mm. B class (3mm to 3.5mm. thickness) 2. Sitting pipe 40mm.B class(3mm to 3.5mm. thickness) 3. Both side vertical structure pipe 40mm. 4.Seat metallic sheet 3mm to 3.5mm. M.S 5. Footrest M.S Checked plate 4mm. thickness 6. Permanent lubricated sealed bearing of reputed brand. 7. Nuts & Bolts Galvanized. 8. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj) |
127 | HS-514 Chest Press Specification- 1. Center main pipe114mm. B class(3mm to 3.5mm. thickness) 2. 2. Sitting pipe 40mm. B class(3mm to 3.5mm. thickness) 3. Both side vertical structure pipe 40mm. 4. Seat metallic sheet 3mm to 3.5mm. M.S 5. Seat moving pipe 2’’x2’’ square M.S 6. Upper handle pipe 40mm. 7. Grip handle 25 mm. 8. Permanent lubricated sealed bearing of reputed brand. 9. Nuts & Bolts Galvanized. 10. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj) |
128 | HS-514 Chest Press Specification- 1. Center main pipe114mm. B class(3mm to 3.5mm. thickness) 2. 2. Sitting pipe 40mm. B class(3mm to 3.5mm. thickness) 3. Both side vertical structure pipe 40mm. 4. Seat metallic sheet 3mm to 3.5mm. M.S 5. Seat moving pipe 2’’x2’’ square M.S 6. Upper handle pipe 40mm. 7. Grip handle 25 mm. 8. Permanent lubricated sealed bearing of reputed brand. 9. Nuts & Bolts Galvanized. 10. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj) |
129 | HS-519 Triple Twister Specification- 1. Center Standing pipe114mm. B class(3mm to 3.5mm. thickness) 2.Bottom twisting legs 32mm. B class(3mm to 3.5mm. thickness) or Iron channel 50mmX100mmX5mm 3. Twister plate 300mm. round 4. Handle Pipe 40mm. B class(3mm to 3.5mm. thickness) 5. Grip handle 25 mm. 6. Permanent lubricated sealed bearing of reputed brand. 7. Nuts & Bolts Galvanized. 8. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj) |
130 | HS-522 Bicycle Specification- 1.Main frame 114mm. B class(3mm to 3.5mm. thickness) 2.Upper frame 50mm. B class(3mm to 3.5mm. thickness) 3. Horizontal support 40mm. B class(3mm to 3.5mm. thickness) 4. Handle Pipe 30mm. B class(3mm to 3.5mm. thickness) 5. wheels Havey duly M.S plate 6. Revolving paddles. 7. Permanent lubricated sealed bearing of reputed brand. 8. Nuts & Bolts Galvanized. 9. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj) |
131 | HS-524 Arm Wheel Specification- 1.Central Standing Pipe 114mm. B class (3mm to 3.5mm. thickness) 2. Both side arm support 40mm. B class (3mm to 3.5mm. thickness) 3.Both side rotating wheels 30mm. B class (3mm to 3.5mm. thickness) 4. Both side central wheel supporting pipe 25 mm. B class(3mm to 3.5mm. thickness) 5. Permanent lubricated sealed bearing of reputed brand. 6. Nuts & Bolts Galvanized. 7. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj) |
132 | Parallel Bar Specification- 1.Central Standing Pipe 114mm. B class (3mm to 3.5mm. thickness) 2. Parallel handle pipe 32mm. B class (3mm to 3.5mm. thickness) 3. Nuts & Bolts Galvanized. 4. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj) |
133 | HS-536 Scaling Ladder Specification- 1.SidePipe 114mm. B class (3mm to 3.5mm. thickness) 2. Bars 30mm. B class (3mm to 3.5mm. thickness) (List of approved makes-Trenz,Garden gym,Bajaj) |
134 | BDC/EQP |
135 | Supply & installation ofbadminton net and poles as approved . |
136 | VLC/EQP |
137 | Supply & installation ofvolleyball net and poles as approved . |
138 | CHP/EQP |
139 | Equipment & accesorries: For Children’s playground |
140 | RTC/EQP |
141 | Supply & installation oftennis net and polesas approved . |
142 | GYM/SYN |
143 | Supply & installation of Silica PU synthetic (List approved Makes -Kdf,Polytan,Stockmeier) |
144 | BDC/SYN |
145 | Supply & installation of ( 8+2)mm synthetic Conipur HG eco system sports flooring approved by International basketball/hand ball / badmintion List of approved Makes-(Conipur HG+, Polytan, Stockmeier) /federation |
146 | Supply and installation of one layer of conipur 70 primer over concrete /bitumensurface at the rate of 0.15kg/sqm |
147 | Supply and installation of 8mm thick shockpad layer with SBR granules mixed with conipur 326 binder at the rate of 6 kg per sqm |
148 | Supply and installation of one layer sealing coat with conipur 220 at the rate of 750gm/sqm over the SBR |
149 | Supply and installation of 2-3mm thick conipur 227 PU |
150 | Supply and installation of top coat color PU paint as per approved shade. |
151 | Line marking as per international norms |
152 | VLC/SYN |
153 | Supply & installation of ( 8+2)mm synthetic Conipur HG eco system sports flooring approved by International basketball/hand ball / badmintion List of approved Makes-(Conipur MX+, Polytan, Stockmeier)/federation |
154 | Supply and installation of one layer of conipur 70 primer over concrete /bitumensurface at the rate of 0.15kg/sqm |
155 | Supply and installation of 8mm thick shockpad layer with SBR granules mixed with conipur 326 binder at the rate of 6 kg per sqm |
156 | Supply and installation of one layer sealing coat with conipur 220 at the rate of 750gm/sqm over the SBR |
157 | Supply and installation of 2-3mm thick conipur 227 PU |
158 | Supply and installation of top coat color PU paint as per approved shade. |
159 | Line marking as per international norms |
160 | CHP/SYN |
161 | Supply & installation of Silica PU synthetic List of approved Makes-(KDF,Polytan, Stockmeier) |
162 | RTC/SYN |
163 | Supply & installation of ( 8+2)mm synthetic Conipur HG eco system sports flooring approved by International basketball/hand ball / badmintion /federation List of approved Makes-(ConipurHG, Polytan, Stockmeier) |
164 | Supply and installation of one layer of conipur 70 primer over concrete /bitumensurface at the rate of 0.15kg/sqm |
165 | Supply and installation of 8mm thick shockpad layer with SBR granules mixed with conipur 326 binder at the rate of 6 kg per sqm |
166 | Supply and installation of one layer sealing coat with conipur 220 at the rate of 750gm/sqm over the SBR |
167 | Supply and installation of 2-3mm thick conipur 227 PU |
168 | Supply and installation of top coat color PU paint as per approved shade. |
169 | Line marking as per international norms |
170 | EBCS/SYN |
171 | Providing and applying external raincoat painting with crack filling acrylic polymer based chemical compound coating to the external surface of wal stoprevent water seepage in the masonry walls during monsoon added with required shade Steiner to give required shade to the surface in two coats. Including providing three coat of priming of polymer base primer including preparing surface scrapping the existing loose old paint, removing loose particles of sand on the surface opening and cleaning the cracks developed in the external plaster, removing loose particles by chiseling, filling cracks by chemicals compound of approved make with proper penetration etc. Coating of Raincoat with the help of brush and as per instructions and specification given by manufacturer and with instruction from Engineer in-charge. Work shall be executed by certified applicator only and covering gurantee of 3 years on court stamp paper of Rs.500/-and necessary testing etc. complete. |
172 | Providing and applying external raincoat painting with crack filling acrylic polymer based chemical compound coating to the external surface of wal stoprevent water seepage in the masonry walls during monsoon added with required shade Steiner to give required shade to the surface in two coats. Including providing three coat of priming of polymer base primer including preparing surface scrapping the existing loose old paint, removing loose particles of sand on the surface opening and cleaning the cracks developed in the external plaster, removing loose particles by chiseling, filling cracks by chemicals compound of approved make with proper penetration etc. Coating of Raincoat with the help of brush and as per instructions and specification given by manufacturer and with instruction from Engineer in-charge. Work shall be executed by certified applicator only and covering gurantee of 3 years on court stamp paper of Rs.500/-and necessary testing etc. complete. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy