Drinking Water Supply and Sanitation Boards / Undertakings / PSU Closing in 0 days TDR #33485592

Renovation Of Apfc Panels At Various Sites For Improvement In Power Factor At Okhla Stp. ( Re-Invite )

Issued by Boards / Undertakings / PSU · okhla, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Aug 2022
0 days left
EMD
23600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
okhla → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Renovation Of Apfc Panels At Various Sites For Improvement In Power Factor At Okhla Stp. ( Re-Invite )

BOQ

Name of Work: Renovation of APFC panels at various sites for improvement in power factor at Okhla STP.
Sl. No. Item Description
1For 45 MGD STP Okhla:- Dismantling /checking of all damaged switchgears, capacitors, measurement instrument, indicating lights, relay and removing of complete wiring and mechanical connection at site and cleaning of APFC panel by CRC.
2Shunt capacitors power 3 phase,415V AC 50Hz MPP type heavy duty in suitable banking as per requirement for power factor Make: Epcos/L&T
3Installationand Banking of capacitors as required withbus bar ,thimble with wiring etc.
4Automatic power factor correction relay 415V digital type with display of power factor Make: Neptune/L&T/EPCOS
5MCB 415V TP 63Amp.Make: L&T /Siemens
6MCB 415V TP 32Amp. Make: L&T /Siemens
7PVCinsulated copper flexible wire16 sq mm Make: Havells/ Kalinga
8Power contactor 220V AC 50Amp. Make: L&T/ Siemens/ TC/ GE
9Power contactor 220V AC70 Amp.(MNX140) Make: L&T/ Siemens
10Power contactor 220V AC 110Amp. Make: L&T/Siemens
11indicating lights R.Y.B. & ON 415V Make: Siemens/ vaishno/L&T
12Auto- Manual Switch Make: Kaycee/L&T
13Sensing current transformer 2500Amp. Class 1 accuracy 15VA. Make: - AE /C&S
14Assembling the components, cleaning all of the panel, fixing of all switchgears i.e. APFC relay contactor, MCB, in their respective chamber duly wired, tapping, tumbling, ferruling and connection with main bus bar both in outgoing incoming part fixing of all measurement components indicating lights, ON-OFF lights etc. at respective space in panel for proper functioning & indicating the status of the panel during running conditions and maintenance of power factor 0.98 or better for six months. This also includes 02 layers of synthetic paint of suitable grade and color in whole panel with paint gun.
15Testing of the equipment’s specification - Continuity and earthing-MCCB mechanism and alignment -Meggaring of all equipment for phase to phase, neutral to body, neutral to earth and phase to earth. - All functional tests-Alignments of doors etc. -interlocking tests -Checking forall tightness of nuts and bolts -Setting of APFC relay parameters to achieve target PF.
16For 16 MGD STP Okhla:- Dismantling /checking of all damaged switchgears, capacitors, measurement instrument, indicating lights, relay and removing of complete wiring and mechanical connection at site and cleaning of APFC panel by CRC.
17Shunt capacitors power 3 phase,415V AC 50Hz MPP type heavy duty in suitable banking as per requirement forpower factor. Make: Epcos/L&T/Neptune
18Installationand Banking of capacitors as required withbus bar ,thimble with wiring etc.
19Automatic power factor correction relay 415V digital type with display of power factor Make: Neptune/L&T/EPCOS
20MCCB 415V TP 160 Amp. with handle & spreader Make: L&T/ Siemens
21MCB 415V TP 63Amp.Make: L&T /Siemens
22MCB 415V TP 32Amp. Make: L&T /Siemens
23PVCinsulated copper flexible wire16 sq mm Make: Havells/ Kalinga
24Power contactor 220V AC50Amp.Make: L&T/ Siemens/ TC/ GE
25Power contactor 220V AC 70Amp. Make: L&T/Siemens
26Power contactor 220V AC 110 Amp.Make: L&T/Siemens
27Indicating lights R.Y.B. & ON 415V Make: Siemens/ L&T
28Sensing current transformer 2500Amp. Class 1 accuracy 15VA. Make: - AE /C&S
29Assembling the components, cleaning all of the panel, fixing of all switchgears i.e. APFC relay contactor, MCB, in their respective chamber duly wired, tapping, tumbling, ferruling and connection with main bus bar both in outgoing incoming part fixing of all measurement components indicating lights, ON-OFF lights etc. at respective space in panel for proper functioning & indicating the status of the panel during running conditions and maintenance of power factor 0.98 or better for six months. This also includes 02 layers of synthetic paint of suitable grade and color in whole panel with paint gun.
30Testing of the equipment’s specification - Continuity and earthing-MCCB mechanism and alignment -Meggaring of all equipment for phase to phase, neutral to body, neutral to earth and phase to earth. - All functional tests-Alignments of doors etc. -interlocking tests -Checking forall tightness of nuts and bolts -Setting of APFC relay parameters to achieve target PF.
31For Main Control room:- Dismantling /checking of all damaged switchgears, capacitors, measurement instrument, indicating lights, relay and removing of complete wiring and mechanical connection at site and cleaning of APFC panel by CRC.
32Shunt capacitors power 3 phase, 415V AC 50Hz MPP type heavy duty in suitable banking as per requirement to maintain power factor. Make: EPCOS/L&T/ Siemens/ Crompton.
33Installationand Banking of capacitors as required withbus bar ,thimble with wiring etc.
34Fast response automatic power factor correction relay 8stage 415V digital type with display of power factor. Make: EPCOS/L&T/ Siemens/ Crompton.
35MCCB of 160amp. 415V AC 3 Phase 50HZ braking capacity 50 KA with thermal magnetic release. Make: L&T/Siemens/Schineder/C&S
36MCCB of 100Amp. 415V AC 3 Phase 50HZ braking capacity 50 KA with thermal magnetic release. Make: L&T/Siemens/Schineder/C&S
37MCB of 63Amp. 415V AC 3 Phase 50HZ, TP. Make: L&T/Siemens/Schineder/C&S
38PVC insulated copper flexible wire 16sqmm. Make: Havells/ Kalinga/ Grandley/ polycab.
39Power contactor 220V AC 50Amp, 3P Make: L&T/Siemens/TC/BCH and DJB approved makes.
40Power contactor 220V AC 70Amp, 3P Make: L&T/SIEMENS/TC/BCH and DJB approved makes.
41Power contactor 220V AC 110Amp. Make: L&T/Siemens/TC/BCH and DJB approved makes.
42Indicating lights LED type 220V ON/OFF. Make: Havells/L&T/BCH.
43Sensing current transformer 2500Amp. Class 1 accuracy 15VA. Make: - AE /C&S
44Assembling the components, cleaning all of the panel, fixing of all switchgears i.e. APFC relay contactor, MCB, in their respective chamber duly wired, tapping, tumbling, ferruling and connection with main bus bar both in outgoing incoming part fixing of all measurement components indicating lights, ON-OFF lights etc. at respective space in panel for proper functioning & indicating the status of the panel during running conditions and maintenance of power factor 0.98 or better for six months. This also includes 02 layers of synthetic paint of suitable grade and color in whole panel with paint gun.
45Testing of the equipment’s specification - Continuity and earthing-MCCB mechanism and alignment -Meggaring of all equipment for phase to phase, neutral to body, neutral to earth and phase to earth. - All functional tests-Alignments of doors etc. -interlocking tests -Checking forall tightness of nuts and bolts -Setting of APFC relay parameters to achieve target PF.

AI Tender Summary

OUR REF NO 33485592
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 18-08-2022
Authority
Authority Name Delhi Jal Board
Work Description Renovation Of Apfc Panels At Various Sites For Improvement In Power Factor At Okhla Stp. ( Re-Invite )
Basic Detail
Tender No NIT No-11 EE (SDW) II/ (22-23)
Bidding Type Tender
Location
City okhla
State Delhi
Key Dates
Publish Date 11 Aug 2022
Submission Date 18 Aug 2022
Open Date 18 Aug 2022
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 23600
Exemption Not Available
Document List
Tendernotice_1.pdf
a9e07905-76e3-445f-a86f-d5e44e15e5f3.html
BOQ_295110.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 18, 2022

Bid Opening Date

Technical bids will be opened and evaluated.