Renovation Of Apfc Panels At Various Sites For Improvement In Power Factor At Okhla Stp. ( Re-Invite )
BOQ
| Sl. No. | Item Description |
| 1 | For 45 MGD STP Okhla:- Dismantling /checking of all damaged switchgears, capacitors, measurement instrument, indicating lights, relay and removing of complete wiring and mechanical connection at site and cleaning of APFC panel by CRC. |
| 2 | Shunt capacitors power 3 phase,415V AC 50Hz MPP type heavy duty in suitable banking as per requirement for power factor Make: Epcos/L&T |
| 3 | Installationand Banking of capacitors as required withbus bar ,thimble with wiring etc. |
| 4 | Automatic power factor correction relay 415V digital type with display of power factor Make: Neptune/L&T/EPCOS |
| 5 | MCB 415V TP 63Amp.Make: L&T /Siemens |
| 6 | MCB 415V TP 32Amp. Make: L&T /Siemens |
| 7 | PVCinsulated copper flexible wire16 sq mm Make: Havells/ Kalinga |
| 8 | Power contactor 220V AC 50Amp. Make: L&T/ Siemens/ TC/ GE |
| 9 | Power contactor 220V AC70 Amp.(MNX140) Make: L&T/ Siemens |
| 10 | Power contactor 220V AC 110Amp. Make: L&T/Siemens |
| 11 | indicating lights R.Y.B. & ON 415V Make: Siemens/ vaishno/L&T |
| 12 | Auto- Manual Switch Make: Kaycee/L&T |
| 13 | Sensing current transformer 2500Amp. Class 1 accuracy 15VA. Make: - AE /C&S |
| 14 | Assembling the components, cleaning all of the panel, fixing of all switchgears i.e. APFC relay contactor, MCB, in their respective chamber duly wired, tapping, tumbling, ferruling and connection with main bus bar both in outgoing incoming part fixing of all measurement components indicating lights, ON-OFF lights etc. at respective space in panel for proper functioning & indicating the status of the panel during running conditions and maintenance of power factor 0.98 or better for six months. This also includes 02 layers of synthetic paint of suitable grade and color in whole panel with paint gun. |
| 15 | Testing of the equipment’s specification - Continuity and earthing-MCCB mechanism and alignment -Meggaring of all equipment for phase to phase, neutral to body, neutral to earth and phase to earth. - All functional tests-Alignments of doors etc. -interlocking tests -Checking forall tightness of nuts and bolts -Setting of APFC relay parameters to achieve target PF. |
| 16 | For 16 MGD STP Okhla:- Dismantling /checking of all damaged switchgears, capacitors, measurement instrument, indicating lights, relay and removing of complete wiring and mechanical connection at site and cleaning of APFC panel by CRC. |
| 17 | Shunt capacitors power 3 phase,415V AC 50Hz MPP type heavy duty in suitable banking as per requirement forpower factor. Make: Epcos/L&T/Neptune |
| 18 | Installationand Banking of capacitors as required withbus bar ,thimble with wiring etc. |
| 19 | Automatic power factor correction relay 415V digital type with display of power factor Make: Neptune/L&T/EPCOS |
| 20 | MCCB 415V TP 160 Amp. with handle & spreader Make: L&T/ Siemens |
| 21 | MCB 415V TP 63Amp.Make: L&T /Siemens |
| 22 | MCB 415V TP 32Amp. Make: L&T /Siemens |
| 23 | PVCinsulated copper flexible wire16 sq mm Make: Havells/ Kalinga |
| 24 | Power contactor 220V AC50Amp.Make: L&T/ Siemens/ TC/ GE |
| 25 | Power contactor 220V AC 70Amp. Make: L&T/Siemens |
| 26 | Power contactor 220V AC 110 Amp.Make: L&T/Siemens |
| 27 | Indicating lights R.Y.B. & ON 415V Make: Siemens/ L&T |
| 28 | Sensing current transformer 2500Amp. Class 1 accuracy 15VA. Make: - AE /C&S |
| 29 | Assembling the components, cleaning all of the panel, fixing of all switchgears i.e. APFC relay contactor, MCB, in their respective chamber duly wired, tapping, tumbling, ferruling and connection with main bus bar both in outgoing incoming part fixing of all measurement components indicating lights, ON-OFF lights etc. at respective space in panel for proper functioning & indicating the status of the panel during running conditions and maintenance of power factor 0.98 or better for six months. This also includes 02 layers of synthetic paint of suitable grade and color in whole panel with paint gun. |
| 30 | Testing of the equipment’s specification - Continuity and earthing-MCCB mechanism and alignment -Meggaring of all equipment for phase to phase, neutral to body, neutral to earth and phase to earth. - All functional tests-Alignments of doors etc. -interlocking tests -Checking forall tightness of nuts and bolts -Setting of APFC relay parameters to achieve target PF. |
| 31 | For Main Control room:- Dismantling /checking of all damaged switchgears, capacitors, measurement instrument, indicating lights, relay and removing of complete wiring and mechanical connection at site and cleaning of APFC panel by CRC. |
| 32 | Shunt capacitors power 3 phase, 415V AC 50Hz MPP type heavy duty in suitable banking as per requirement to maintain power factor. Make: EPCOS/L&T/ Siemens/ Crompton. |
| 33 | Installationand Banking of capacitors as required withbus bar ,thimble with wiring etc. |
| 34 | Fast response automatic power factor correction relay 8stage 415V digital type with display of power factor. Make: EPCOS/L&T/ Siemens/ Crompton. |
| 35 | MCCB of 160amp. 415V AC 3 Phase 50HZ braking capacity 50 KA with thermal magnetic release. Make: L&T/Siemens/Schineder/C&S |
| 36 | MCCB of 100Amp. 415V AC 3 Phase 50HZ braking capacity 50 KA with thermal magnetic release. Make: L&T/Siemens/Schineder/C&S |
| 37 | MCB of 63Amp. 415V AC 3 Phase 50HZ, TP. Make: L&T/Siemens/Schineder/C&S |
| 38 | PVC insulated copper flexible wire 16sqmm. Make: Havells/ Kalinga/ Grandley/ polycab. |
| 39 | Power contactor 220V AC 50Amp, 3P Make: L&T/Siemens/TC/BCH and DJB approved makes. |
| 40 | Power contactor 220V AC 70Amp, 3P Make: L&T/SIEMENS/TC/BCH and DJB approved makes. |
| 41 | Power contactor 220V AC 110Amp. Make: L&T/Siemens/TC/BCH and DJB approved makes. |
| 42 | Indicating lights LED type 220V ON/OFF. Make: Havells/L&T/BCH. |
| 43 | Sensing current transformer 2500Amp. Class 1 accuracy 15VA. Make: - AE /C&S |
| 44 | Assembling the components, cleaning all of the panel, fixing of all switchgears i.e. APFC relay contactor, MCB, in their respective chamber duly wired, tapping, tumbling, ferruling and connection with main bus bar both in outgoing incoming part fixing of all measurement components indicating lights, ON-OFF lights etc. at respective space in panel for proper functioning & indicating the status of the panel during running conditions and maintenance of power factor 0.98 or better for six months. This also includes 02 layers of synthetic paint of suitable grade and color in whole panel with paint gun. |
| 45 | Testing of the equipment’s specification - Continuity and earthing-MCCB mechanism and alignment -Meggaring of all equipment for phase to phase, neutral to body, neutral to earth and phase to earth. - All functional tests-Alignments of doors etc. -interlocking tests -Checking forall tightness of nuts and bolts -Setting of APFC relay parameters to achieve target PF. |
AI Tender Summary
Tender Timeline
Aug 11, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedAug 18, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 18, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender