| 1 | Construction of Embankment with Material Obtained from Borrow PitsConstruction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per MoRD Technical Specification Clause 301.5. |
| 2 | Painting Two Coats on New Concrete SurfacesPainting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new plastered / concrete surfaces as per drawing and MoRD Technical Specification clause 1701. |
| 3 | Excavation for StructuresWithout dewatering.Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, dewatering, construction of shoring,shuttering & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material..(I) Ordinary Soil(i) Upto 3 m depth |
| 4 | Filling in foundation trenches as per drawing & MoRD technical specification Clause 305.3.9, 1200 |
| 5 | (I) Sand filling |
| 6 | II Earth filling (For marshy soil) |
| 7 | Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centring, shuttering, staging etc. but excluding reinforcement ) |
| 8 | (I) P.C.C grade M 10 (Using Jhamma brick aggregate)(i) Nominal mix 1:3:6 |
| 9 | II P.C.C grade M 15 (using jhama brick aggregate)(i) Nominal mix (1:2.5:5) |
| 10 | Brick masonryworkincement mortarin substructure complete excepting pointing & plastering, as per drawing & MoRD technical specification Clauses 602, 603, 604, 1202 and 1204.II. In 1:4 cement mortar |
| 11 | Plastering withcementmortar (1:4)15mmthickon brickwork in substructure as per MoRD technical specification Clauses 613.4 & 1204. |
| 12 | Plain/reinforced cement concrete in substructure complete including formwork as per drawings &MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centring, shuttering, staging etc. but excluding reinforcement )VI. R.C.C. grade M 25(i) Up to 5 m height |
| 13 | Supplying, fitting & placing Thermo-Mechanically treated bar/cikd twisted deformed steel bar in substructure complete as per drawings & MoRD technical specificationClauses 1002, 1005, 1010 and 1202 |
| 14 | Providing weepholes in brick masonry / stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or PVC pipe (110 mm OD of 6.0 kg/cm^2 pressure) extending through the full width of the structures with slopw of 1(V): 20(H) towards drwaing face complete a sper drawing and MoRD technical specification clauses 614, 709, 1204.3.7. |
| 15 | Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil& bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8. |
| 16 | Providing & laying reinforced cement concrete in superstructure as per drawings & MoRD technical specifications Clauses 800, 900, 1205.4 & 1205.5 (including centring, shuttering, staging etc. but excluding reinforcement )II. R.C.C M 251. For height up to 5 m |
| 17 | Supplying, fitting, & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in superstructure complete as per drawing & MoRD technical specifications Clauses 1002, 1010 & 1202. |
| 18 | Brick masonryworkincement mortar1:3inparapet excluding pointing & plastering as per drawing & plastering as per drawing & MoRD technical specifications Clauses 600, 900 & 1208.4. |
| 19 | Spreading of Sludge / Farm Yard Manure / good EarthSpreading of sludge/ farm yard manure/ good earth in required thickness (cost of sludge, farm yard manure or/ and good earth to be paid for separately) MoRT&H technical specifications Clauses 307. |
| 20 | Grassing with \"Doobs\" GrassGrassing with \"Doobs\" grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed as per MoRT&H technical specifications Clauses 307.ii. In rows 75 mm apart in all direction |
| 21 | Wrought Iron and Mild Steel Welded WorkWrought iron and mild steel welded work (using angles, square bars, tees and channel in grills, grating frames, gates and tree guards of any size and design etc. including cost of screens and welding rods or bolts and nuts complete fixed in position but without the cost of excavation and concrete for fixing which will be paid separately as per MoRT&H technical specifications Clauses and as directed. |
| 22 | Planting and Maintaining of Permanent HedgesA. Planting permanent hedges including digging of trenches Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart |