BOQ Items

Name of Work: Beautification of Football Ground, Moti Daman
Sl. No. Item Description
1Works
2Providing material and labour, machinery for Excavation of foundation/utilities upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff within the site for all lead, all lift/ depth anywhere from the site etc complete as directed by Engineer in charge. for all kind of soil.
3Providing material and labour for Excavation of foundation/utilities from1.5 mtto3.0 mt depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in the site for all lead, all lift/ depth (excluding hard rock) anywhere from the site etc complete as directed by Engineer in charge. for all kind of soil.
4Providing material and labour for Filling in foundation, plinth and plot filling with murrum (brought from out side) CBR value higher than 8% in layers of 20cm. thickness including watering, ramming and consolidating etc complete as directed by Engineer in charge.
5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each depositedlayer by ramming and watering. (Ramping by manual or mechanical means)
6Disposing off the un-used excavatedearth for all lead and lift/ depth out side the site at non objectional place as directed by Engineer in charge.
7Providing material and labour for Fillingin plinth with coarse sand with CBR value higher than 8% under floors or base of foundation including watering ramming, consolidating and dressing etc complete as directed by Engineer in charge.
8Providing and filling in rubbles in foundation, in plinth and for plinth protection, filling, with quarry spalls covering and leveling the surface in layers of 20 cm thickness stone/metals or stone chips, including watering, ramming well and consolidating each layer using minimum 100mm cut size stones. (Ramping by manual or mechanical means)
9Carrying out plinth treatment to post construction / existing structure by spraying chemical solution for termite controltreatment including labour and material consistment with I.S.I specification. Using Chlordene and Chiorpurfiles 20 EC. As Per 6131_paret-IIConcentration Weight one percent is recommended i.e one litre 20 EC chemical emulsionwith 19 liter give 1 % concentration inclusive of one litre chemical emulsion application at the rate of 5Litre chemical / Sqm of surface is recommendedas per I.S
10Dewatering in all sorts of soil and soft murrum, hard Murrum and boulders, Soft Rock, Hard Rock including removal of surface water, water from foundation, trenches and ground water as nessesary to performed construction required by the contract in accodance with the specification.
11Providing and laying cement mortar in 1:6 (1-Cement : 6-coarse sand) proportion.
12Providing material and labour for laying Plain cement concrete 1:4:8 (1- Cement : 4- Coarse sand : 8- crushed stone aggregates 20 mm-40mm nominal size) in Foundation, Plinth, Pavement, Road work including cost of formwork, compacting, finishing, curing etc complete for all level, all height/ depth as directed by engineer in charge.
13Providing material and labour for laying in position batched and machine mixed design controlled cement concrete M25 below plinth level produced in batch mix machine, using cement content as per approved design mix, including pumping of concrete to site of laying including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete workin Foundation, footings, base of columns, pavement, grade slab, roads and Mass concrete including cost of Formwork with centering,new steel/plywood shuttering, strutting, steel scaffolding and propping etc. exluding cost of reinforcement and removal of the same for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
14Providing material and labour for laying controlled cement concrete M25 produced in batch mix machine, using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to minimum cement level content of 450kg (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete workin Columns, Fins, Pillars posts, Rectangular polygon in plan and struts upto plinth level including cost of Fair /Expose RCC finish Formworkwith centering, steel/ply shuttering, strutting, steel scaffolding and propping etc. exluding cost of reinforcement.Height of propping and centering below supporting floor to ceilingnotexceeding 4 M and removal of the same for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
15Providing material and labour for laying controlled cement concrete M25 produced in batch mix machine, using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to minimum cement level content of 450kg (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete workin Columns, Fins, Pillars posts, Rectangular polygon in plan and struts upto floor two level including cost of Fair /Expose RCC finish Formwork with centering, steel/ply shuttering, strutting, steel scaffolding and propping for all columns (square,rectangle,circular etc.) exluding cost of reinforcement.Height of propping and centering below supporting floor to ceilingnotexceeding 4 M and removal of the same for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
16Providing material and labour for laying in position batched and machine mixed design controlled cement concrete M25 produced in batch mix machine, using cement content as per approved design mix, including pumping of concrete to site of laying including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete workin Walls upto plinth, including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. exluding cost of reinforcement. and removal of the same for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
17Providing material and labour for laying in position batched and machine mixed design controlled cement concrete M25 produced in batch mix machine, using cement content as per approved design mix, including pumping of concrete to site of laying including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete workin Walls upto floor two level, including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. exluding cost of reinforcement. and removal of the same for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
18Providing material and labour for laying in position batched and machine mixed design controlled cement concrete M25 from below plinth upto floor V level produced in batch mix machine, using cement content as per approved design mix, including pumping of concrete to site of laying including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete workin Slabs, Grade Slab, landing, lintels, shelves, Balconies and Cantilever including cost of expose/fair finish Formwork including cost of Formwork with centering, new steel/plywood shuttering, strutting, steel scaffolding and propping etc. exluding cost of reinforcement. Height of propping and centering below supporting floor to ceilingnotexceeding 4.0 M and removal of the same for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
19Providing material and labour for laying controlled cement concrete M25 produced in batch mix machine, using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregatesconforming to minimum cement level content of 450kg (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete workin Beams, Plinth beam, Girders and Cantilever upto plinth level including cost of Fair /Expose RCC finish Formwork with centering, steel/ply shuttering, strutting, steel scaffolding and propping etc. exluding cost of reinforcement. Height of propping and centering below supporting floor to ceilingnotexceeding 4 M and removal of the same for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
20Providing material and labour for laying controlled cement concrete M25 produced in batch mix machine, using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregatesconforming to minimum cement level content of 450kg (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete workin Beams, Girders, Lintels and Cantilever upto floor two level including cost of Fair /Expose RCC finish Formwork with centering, steel/ply shuttering, strutting, steel scaffolding and propping etc. exluding cost of reinforcement. Height of propping and centering below supporting floor to ceilingnotexceeding 4 M and removal of the same for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
21Providing material and labour for laying controlled cement concrete M25 produced in batch mix machine, using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregatesconforming to minimum cement level content of 450kg (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete workin stair and landing all work upto floor V level upto floor two level including cost of Fair /Expose RCC finish Formwork with centering, steel/ply shuttering, strutting, steel scaffolding and propping etc. exluding cost of reinforcement. Height of propping and centering below supporting floor to ceilingnotexceeding 4 M and removal of the same for in situ reinforced concrete and plain concrete work in with all lead and lift complete as directed by engineer in charge.
22Providing and Core cutting work in Stone/RCC/Brick structures of maximum 400mm depth upto 150mm Dia with required core-cutting wet drilling, fastners tools, labour and supervision etc complete.
23Providing material and labour for fixing in position PVC pipe sleeves 75-160mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleeve shall be removed before water proofing or grouting (at rain water down take location).
24Rebaring: Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into Stone masonry/RCC wall (with Hilti RE500V3 or Fischer FIS EM or Equivalent) as per manufacturer"s specification and structural consultant"s specification and fixing rebar of the required diameter subsequently upto 25 mm dia. drill hole and 450mm anchoring depth. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item.Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge.
25Providing & laying weep hole in Abutments, walls and returns by using A.C. pipe of 100mm including laying in proper grade and jointing the completed as per detailed specification.
26Supplying, cutting, bending, binding and placing in position TMT Bar Fe 500D reinforcement in all diameter confirming to relevant I.S. standards as per ISS 2502 and IS 1786 including cost of binding with GI wires and placing in position complete upto floor two level inluding Providing anticorrosive treatment to HYSD/Fe 500D bars with FUSION BONDED EPOXY COATING (FBEC) confirming to IS13620:1993 at approved plant including testing of coating as per relevant IS, before bringing the coated bars on site including To & Fro transportation of bars for sending at plant site etc. complete, for HYSD bars. (Brands: Tata, Jindal)
27Steel works: Providing material and labour for fabricating, assembling, hoisting/ erecting and fixing in position at all heights/ all levels/ all floors/ all shapes & sizes with all leads & lifts using MS Rolled Steel Sections, ISMB, ISMC, UC, H-Section, Hollow sections, Tubular Sections, MS Plates, Chequered Plates, MS Pipes, Perforated Sheet, Flats, Bars, Angles, MS Sheet, Girder, Beam, cattle trap, deep threaded MS bolts. All confirming to latest relevant IS codes for the work of steel structures like staircases, railings, handrail, jali, gates, grills, bracings, platforms, brackets, monkey ladder, cattle trap, rungs, Roof canopy, fencing posts, M.S. Screen etc. including straightening, cutting, bending, bolting and welding the members including necessary scaffolding/ staging etc. complete and comprising of Profile Cutting, Smooth grinding/ machining of edges/ faces/ all welding joints; Necessary welding; Machine drilling of holes for joining/ anchoring; dry sanding, degreasing (wet cleaning) & preparation of rustfree surface manually or mechanically, metal putty to make the surface even and smooth. The Contractor shall prepare shop drawing as per GFC drawing and as per actual site condition and get approved before execution by EIC. (Standard measurements will be paid for as actual cut length used at site) .(Brand: Tata Steel, Jindal)
28Providing and fixing M.S. round holding down or anchor bolts with nuts and washer plates complete.
29Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg/SqCm in foundation and plinth in Cement Mortar 1:5 (1- Cement : 5 -fine sand) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
30Providing material and labour for Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. insuperstructure above plinth level upto floor two level (B) Cement Mortar 1:5. (1- Cement : 5 -fine sand)in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
31Providing material and labour for (i) Halfbrickmasonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1-Cement : 4 -coarse sand ) in foundation, plinth and superstructure above plinth level upto floor two level,in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
32Providing and fixing frames/shutters/louvers for any type of aluminium works in door/window/partition made out ofheavy weight extruded aluminium sections of approved make having minimum 50 micron pure polyesterPowder Coated coating of approved shade, texture & colour for all floors, levels, heights, shapes, sizes including cutting, bending, crimping, fabricating in best workmanship manner etc excluding glass works as per the drawing and as directed by Architect or EIC. Including 1) Sheet metal screws and casted solid aluminum corner cleats fixed with external byttins with a spring for rapid and secure joint assembly for casement and sliding shutter and frame;2) Glazing clips for receiving infill panel; 3) Best quality wool pile and compatibleEPDM rubber; 4) Dash Anchor fasteners of HILTIor equi. for fixing the frame at every 600 mm spacing. 5) 10mm GI tie rod for connecting vertical stile at top and bottom for aluminum door shutter and 4mm thick solid aluminium corner cleat of full thickness of sectionfor connecting style and horizontal rails; 6) Providing and fixing packing (rough ground) in full periphery/ at every 600mm c/c with average 6 mm thick PVC spacer/ compact sheet of width ; 7) Filling the gap between wall and frame on both sideswith polyethylene baker rod of avg. 10 mm thickness with silicon sealant . 8) Termite treated seasoned teak wood. 9)Zinc alloy powder coated touch lock with hook. 10) Zinc alloy body with single nylon roller (weight bearing capacity to be 40 Kg). Contractor shall prepare shop drawing based on concept drawing and get approved from the consultants before procurement of material including making of mock up for approval with all hardwares. Rate shall be inclusive of all material, labour, fixing, accessories.(make: HIFAB, DOMAL)
33Providing and fixing fibreglass Mosquito nets fixed in window frames/shutters/ louvers with all required accesories of approved brand, powder coated and plastic components with weather stripping of polypropylene with track profiles for smooth operation in channel, colour as required and all complete as per direction of EIC. (excluding cost of aluminium frames and shutters)
34Providing and fixing 5mm thk float glass panel frosted/plain glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): Actual installed quantity shall be measured and paid. Rate shall be inclusive of all type of wastage.
35Providing and fixing 35 mm thick flush door filled with country wood, water proof flush door single shutters with 1 mm high end laminate sheet (Brand:Royale touche, Greenlam, Century ply) on both side of the door with lipping edging patti all around the door. The door would have vision glass panel with 5mm glass including cutting, fixing all where required. The door with also have accessory like 2 Nos pull SS handles in Brush finish of the size 25mm diameter, 30 cm long made from anticorrosive high grade AISI 316 stainless steel hinges. Providing and fixing one number of 10 mm diameter 20 cm long anticorrosive high grade AISI 316 stainless steel tower bolt, with fixing SS heavy duty screws to the frame as approved by Engineer -in-charge etc. complete as per detailed drawing. ALL FLOORS. (Allaccessoriesbrand: Ozone, Kich)
36Providing and fixing 25 mm thick flush door filled with country wood, water proof flush door single shutters with 1 mm laminate sheet (Brand:Royale touche, Greenlam,Century ply) on external side and waterproof PVC laminated sheet (Brand: Royale touche, Skydecor) internal side of the door with lipping edging patti all around the door includingusing 2 Nos pull SS handles in brush finish of the size 25mm diameter, 15 cm long made from anticorrosive high grade AISI 316 stainless steel. Providing and fixing four numbers of anticorrosive high grade AISI 304stainless steel hinges of size 102 mm x 76 mm x 3 mm & anticorrosive high grade AISI 316 stainless steel 2 no.s Latch in matt finish, with fixing SS heavy duty screws to the frame as approved by Engineer -in-charge etc. complete as per detailed drawing. ALL FLOORS. (Allaccessoriesbrand: Ozone, Kich)
37Providing and applying 1mm thick core laminate sheet on door/wooden members/facias etc including cleaning and rubbing existing surface and applying sheet without any air gap as approved by Engineer -in-charge etc. complete as per detailed drawing. ALL FLOORS (Make:Greenlam/Royale Touche/ Euro)
38Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (Brand: Ozone, Kich)
39Providing & fixing Locks Godrej Mortice lock cover (with 3 sets of key) with all required tools and tackles, gaskets, screws in line and level at the height mentioned in the drawing, cutting and core the doors in exact dimensions, without damaging the shutter or frames up to the satisfaction of engineer in charge with Standard warranty of 1 year
40Providing & fixing S.S. Pipe Handle of 30 Cm size of ASIS 316 Grade with all required tools and tackles, gaskets, screws in line and level at the height mentioned in the drawing up to the satisfaction of engineer in charge. (Brands KICH, OZONE AND ENOX)
41Providing & fixing S.S. Pipe Handle of 10 Cm size of SS 304 Grade with all required tools and tackles, gaskets, screws in line and level at the height mentioned in the drawing up to the satisfaction of engineer in charge. (Brands KICH, OZONE AND ENOX)
42Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. (Brand Ozone, Kich, Enox)
43Providing and fixing IS:12817 marked stainless steel butt hinges of 4x1x1" inches with stainless steel screws etc. complete in doors, windows, louvers as per drawings.
44Providing & fixing Louvers of Anodized aluminium sections as horizontal members at 75 mm c/c and 100 x 25 x 2 mm (Wt. 1.16 kg/m) aluminium vertical section 125x25X2 mm (Wt. 1.43 kg/m)with SS 304 Aldrop 20 cm long including fixing and erection on site and making surface good etc. complete as per design for doors/windows/ventilators.
45Providing and fixing in position, interlocking rolling shutter of approved make, made of 18 gauge, 75mm wide cold rolled GI lath interlocked, including top cover (20 gauge), spring, axles (specially designed shaft), guide rails (10 gauge), tees, iron pulleys, ball bearings, handles, arrangement for inside and outside locking arrangement, with Mechanical Type (Gear Arrangement), holding down bolts embedded in CC 1:2:4 / anchor fastener of HILTI or equivalent including 1 coat of Rustocap and 2 coat of Hi-Gloss Metal PU Paint of approved make and shade over all the surfaces etc. as directed. (Measurements considered for payments shall be clear size of opening plus guide channels on both the sides for width and 450mm on top for drum height.)
46Providing and fixing upto floor two level precast jali blocks extruded wire cut made with 100% red natural burnt clay with fair finish look including cleaning, fixing and finishing in cement mortar 1:3, curing and pointing works at all heights with necessary scaffolding etc complete as per direction of Engineer in charge. Shape of hollow part shall be round, square or rectangle and in pattern, provision of groove and pointing as per drawing, curingContractor shall prepare mock up for one panel with approved block and as per satisfaction of Architect. Note: Payment should as per actual area of jali made, no deduction of hollow gap of block or wastage should be considered for payment. (Brand: Banglore Tile Company, Brick Store, Wienerberger)
47Providing, making and fixing backlight sign with SS 304 Grade Hairline finished Acrylic Letters with LED of 18 inches height, made of SS sheet of 1.0 thick and fixed with embose of 1.25 inches from the wall for signage and the font style as approved sample or as per design and drawings. It shall be made from ISI Brushed S.S. 304. It shall be fixed on the wall with chemical anchor fastener at any level any height. All Edges and corners shall be smoothened. Width of the letter shall as per the proportion of the word for depth. The rate shall be inclusive of scaffolding, drilling, adhesive material, screwing, stud fitting, buffing etc. complete for all heights with 5 year warranty and and maintainance.
48Providing and fixing stainless steel (Grade 316) Railing and baluster system of approved make stair railing, hand rail, bump rail, guard rail, with knock down system made of Hollow or solid secion i.e. tubes, square, flat, plates, bar etc with base plate Cover cap, finishing accessories, infilled holding brackets, fixing accessories etc. for any type of design, shape (plain/ curvature), size as per drawing. Railing shall be top mounted or side/ wall mounted. Railing shall be fixed with SS 316 grade anchor fastner of required size and as per fixing position of approved make. No Weilding OR Fabrication shall be allowed at site.(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Sample shall be approved before execution. Contractor shall arrange mock up of railing system (2 or 3 no) in required length as directed by Architect. Contractor shall protect railing system uptill handling over the project.
49Providing throating or plaster drip groove 10 x 10 MM and moulding to RCC chajja and horizontal surfaces.
50Providing material and labour for fixing G.I. hexagonal chickenmesh of size 16mm x 24mm of 22 gauge at junction of concrete and brick work or between different materials after making "V" grove between two different material surface and filled with rich cement mortar and@ 100mm on each side of surfaces including necessary "U" nails/ screws/ washers with cleats for fixing, overlaps, curing, scaffolding etc complete for all floors/ all levels/ all heights/ all shapes as per direction of Engineer-in-charge.
51Providing and applying 10mm thick cement plaster in single coat plastering on ceilings and sofits of stairs upto all levels/floors (i)Cement mortar 1:3 (1-cement:3-sand) including finishing with a floating coat of neat cement slurry, scaffolding, curing, finishing, making grooves, forming pattas etc. complete as directed by the Engineer-in-charge.
52Providing and applying 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick/ AAC blockswalls for plastering upto all levels/floors and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand). Including scaffolding, curing, finishing, making grooves, forming pattas etc. complete as directed by the Engineer-in-charge.
53Providing and appying 20mm thick sand faced cement plaster on walls upto height 10metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete. Including scaffolding, curing, finishing, making grooves, forming pattas etc. complete as directed by the Engineer-in-charge.
54Providing 20 mm thick double coat mala cement plaster on brick work / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including scaffolding curing etc. complete.
55Providing and applying Wall painting (two coats) with plastic emulsion paint of approved brand having VOC (Volatile Organic Compound) content and manufacture on undecorated wall surface to give an even shade including required scaffolding, thoroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.( make Asian, Berger, Dulex, Nerolac)
56Providing and applyingtwo coats of Birla (white cement based) or Asian (acrylic lapy- putty) or equivalent & two coats of primer of approved brandand manufacture on new wall surface to give an even shade including required scaffolding, thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.
57Providing material and labour for Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete inluding required scaffolding. (make: Asian paint, Berger, Dulex, Nerolac)
58Providing material and labour for anti-mould medium grain Textured finish made with selected marble chips of required shade on external wall surface including thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete inluding required scaffolding with providing putty with putty knife where necessary. applying exterior wall primer with brush then apply two coats including base coat of apex ultima allura torino using steel trowel and two-three coats of apex ultima as top coat with brush/ spray/ roller all complete as per EIC. (make: Asian paint)
59Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles of required size having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have, light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC.for the best thermal Insulation. The Light weight calcium Silicate tile shall be of approved texture Fine fissured/ Spintone/Cosmos having NRC value of 0.5 & Globe having NRC value of 0.75 NRC or equivalent of size 595 X 595 mm to be laid on true horizontal level suspendedinter locking metal grid of hot dipped galvanized steel sections (galvanizing@120 grams per sqm ”ncluding both side) consisting of main "T’ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross‘T’ of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ’T’ at 600mm centre to centre to form agrid of 1200X600mm and secondary cross ’T’ of length 600mm and size 24x28mm made of 0.30 mm thick (Minimum) sheet to be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mm resting on periphery walls/partitions on a perimeter wall angle pre-coated steel of size (24X24X3000mmmade of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall.
60Metal Paint: Providing material and labour for applying Epoxy based Paint for Metal works on new/ existing metal surface af including including cleaningand removal of all dirt, grease, varnish, paint or any other foreign matter. Hereafter surface sanding before and after the paint to provide seamless aesthetic look complete as per the instructions with proper tools and sanding and wire brushing. First application of 2 coast of epoxy based primer (Epoxy Zinc Phosphate primer) paint to be applied and there after application of putty works and sanding work, thereafter application of 2 coats of epoxy base paint finish. Sample to be approved before starting of the work by Architect/ EIC. Rate shall be inclusive of the cost of scafolding. (Brands: Jotun, Asian paint Apcolite Epoxy)
61Providing and applying Hot dip Galvanised coating confirming toIndian Standard 4579/2629/2633 with zinc coating thickness to be 86 micron and before application ofGI coating the material should be free from all dirt, grease, varnish, paint or any other foreign matter. Including touching of local exposed areas with Zincmetal spray paint to make the structure corrosion free with cleaning thoroughly the applied surface making it free from grease, paint or any other foreign matter , sanding the surface before and after the paint to provide seamless aestheic look complete as per the instructions of the EIC including transport/loading/unloading the materials at plant for HDGC work
62Providing and Laying broken China mosaic flooring for terrace using 12 to 20 mm broken pieces of only white glazed tiles (Bell/ Somany/ Johnson/ kajaria/ Cera/ Spartek/Orient / Nitco) to be laid over cement mortar 1:3 to plain or slope and to be tempered to bring mortar cream out up to surface using white cement including off junctions and extending them up to wall top, curing with water and cleaning with oxalic acid etc as directed.
63Providing and laying integral cement based water proofing treatment conforming to IS: 2645 for treatment of roofs, balconies, terraces etc: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brickbats 25 mm to 115 mm size with 50% of cement mortar 1:5 admixed with water proofing compound over 20 mm thick layer of cement mortar of mix 1:5 admixed with water proofing compound to required slope and treating similarly the adjoining walls upto 300 mm height rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 admixed with water proofing compound conforming to IS : 2645 and approved by EIC.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by EIC including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) Curing terrace with water flooded for min. 2 weeks. All above operations to be done in order and as directed and specified by the EIC with average thickness of 120 mm and minimum thickness at khurra as 65 mm.
64Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
65Providing cement vata (10 cm X 10 cm size) quarter round in Cement Mortar 1:1 including neat cement finishing, watering etc complete
66Providing coloured corrugated in required thickness (min. 0.8 mm thk.)G.I. sheet of class-3 roofing fixed with glavanished iron J or L Hooks, Bolts and nuts 8mm diameter with bitumen and G.I. limpet washer or G.I. limpet washer. filled with white lead complete including valleys, excluding the cost of purlins, Rafters and Trusses
67Providing and laying 25 mm thick chisled/natural finish Kota stone machine cut flooring over 20mm thick base of cement mortar 1:5 (1-Cement : 5-coarse sand) or L.M. 1:1.5 including pointing with cement mortar 1:2 (1-cement : 2-stone dust) etc. complete. (A) 25 mm thick
68Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1- cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishingetc. complete. (A) 25mm thick.Sample shall be approved before execution. Kota stone shall be in uniform shade of required size. Sample and mockup shall be approved before procurement of material.
69Providing and laying POLISHED Granite stone 25mm thk flooring/wall in required design and patterns, in linear as well as curvilinear portions all complete as per the architectural drawings with 25 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laidand jointed with cement slurry and pointing with cement slurry admixed with pigment of matching shade including wastage,rubbing, cutting, curing and polishing etc all complete as specified and as directed by theEngineer-in-Charge: Colour Jet Black, Cherry Red, Steel grey, Elite Brown, Cat Eye or equivalent.
70Providing and fixing 20 mm thick Granite gang saw cut, mirror polished, premoulded and prepolished, machine cut for wall cladding,plaforms, vanity counters, window sills, facades, in linear as well as curvilinear surfaces and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) or chemical adhesive, joints treated with epoxy matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Including fixing granite stone, over and above corresponding basic item, in facia, wall claddingand drops with chemical adhesive, including cleaning etc. complete. For all wall Caldding and Copping work also as per drawing including all colour and texture. (Brand for Adhesive:MYK Laticrete, Weber,Kerakoll)
71Providing Edge moulding/buffing upto 25 mm thickGranite/Kota/ other stones, counters, Vanities, steps/ riser etc., including machine polishing to edge to give high gloss finish etc.including wastage,rubbing, cutting, providing grooves, curing and polishing etc complete as per design approved byEngineer-in-Charge.
72Providing and laying double charged Antiskid vitrified tiles in floor/skirtings wherever reuired (thickness to be specified by manufacturer) with residue of approved make and shade as per drawing with water absorption less than 0.08% and confirming to IS: 15622, laid over 20 mm thick cement mortar 1:6 (1 cement : 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc with bedding of approved make, in all colours and shades. Finishing shall be done with pointing the joints with grey cement/ epoxy grout slurry at 3.3kg/sq m including grouting the joints with white cement and matching pigment, including curing, cleaning with mild oxalic acid, maintaining till handling over by covering with plastic sheet etc complete for all floor all height as directed by Engineer-in-charge. (Brands: Simpolo, Nexion, Johnson, Kajaria, Asian, NITCO)
73Providing and laying fullbody vitrified tiles in floor/walls/ dado/skirtings wherever required (thickness to be specified by manufacturer) with residue of approved make and shade as per drawing with water absorption less than 0.08% and confirming to IS: 15622, laid over 20 mm thick cement mortar 1:6 (1 cement : 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc with bedding of approved make, in all colours and shades. Finishing shall be done with pointing the joints with grey cement slurry/ epoxy grout at 3.3kg/sq m including grouting the joints with white cement and matching pigment, including curing, cleaning with mild oxalic acid, maintaining till handling over by covering with plastic sheet etc complete for all floor all height as directed by Engineer-in-charge. (Brands: Simpolo, Nexion, Johnson, Kajaria, Asian, NITCO)
74Construction of Granular sub-base (GSB) by providing close graded Material conforming to specifications, mixing in place method with rotavator at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
75Rolling of earthwork in layers with power roller including filling in depressions which occur during the process including watering of earthworks.
76Providing and fixing pre-cast fair finish concrete kerb stone with vacuum wethydraulic pressing technology of M25 grade cement based concrete block 60x30cm LXH and 15 cm thick as per approved design and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete including corner, quadrants, angles, radius, dropper kerbs in all shapes (Brands: Vyara, Alcock)
77Construction of Dry Lean Cement Concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blend.Withminimum cement Consumption 150kg/Cum.
78Construction of un-reinforced, dowel jointed, plain cement concrete pavement of M40 Broom Finish / polished finish over a prepared sub-base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS:383, maximum size of coarse aggregate not exceeding 25mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form paver, spread, compacted and finished in a continuous operation including provision of contraction, vaccum de-watering, shuttering expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, deboning strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawings. To be laid in alternate panels size apprx 4.5mt X 4.5 mt with fair finished steel channelformwork.
79Providing and laying Riverwashed Granite stone 25mm thk flooring/wall in required design and patterns, in linear as well as curvilinear portions all complete as per the architectural drawings with 25 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laidand jointed with cement slurry and pointing with cement slurry admixed with pigment of matching shade including wastage,rubbing, cutting, curing and polishing etc all complete as specified and as directed by theEngineer-in-Charge: Colour Jet Black, Cherry Red, Steel grey, Elite Brown, Cat Eye or equivalent.
80Providing and laying Riverwash kota stone 25 mm thk stone slab/ flooring/ steps/ risers /wall mounted with edge cutting in required sizes, design and patterns, in linear as well as curvilinear portions all complete as per the architectural drawings over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with cement slurry admixed with pigment of matching shade including wastage,rubbing, cutting, curing and polishing etc all complete as specified and as directed by theEngineering- Charge.
81Providing and laying Flamed finish machine cut Rajula stone of 22-25 mm thk stone slab/ flooring/wall mounted with edge cutting in required sizes, design and patterns, in linear as well as curvilinear portions all complete as per the architectural drawings over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with cement slurry admixed with pigment of matching shade including wastage,rubbing, cutting, curing and polishing etc all complete as specified and as directed by theEngineering- Charge
82Providing and laying Concrete modular paving stone Rustico in diffrent available sizes and colours with high density average 70 mm thick having compressive strength of 400 Kg/cm2 for pathways,roads, parking areas, service lanes and other areas.  Including providing and laying average 50 mm thick average bedding layer of coarse sand/ mortar below the block as per required grading and specification. Laid blocks shall be mechanically compacted. The Finished surface of the block shall have textured finish.It should be laid in such a way that the no cutting of the paver block to be necessary and if required, cutting of paver block by machine cut only. The Finished surface of the paver block shall texture finish.Sample to be approved before starting of the work by Architect/ EIC. The blocks shall be compacted and shall be re-laid if necessary. As per size and material specification, Brands: VYARA, “basant betton”
83Providing, Laying and fixing Cement concrete paver block shot blasted M 250 grade of approved make and shape 60 mm thick to be fixed on 75mm sand layer, laying the paver blocks in pattern as directed by the EIC including joint filled up with coloured cement to match the shade of tiles and colour (in different colour combination), rolling and mechanically compacting with appropriate tools and plants, all conveyance including loading, unloading of blocks etc. complete as directed by architect. It should be laid in such a way that the no cutting of the paver block to be necessary and if required, cutting of paver block by machine cut only. The Finished surface of the paver block shall have coarse sand texture finish.Sample to be approved before starting of the work by Architect/ EIC.Make: Vyara, Super
84Providing and laying Tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
85Providing and fixing Precast Composite Concrete Litter Bin of 600x600x1000 (LxBxH) each unit weight 75 kg as single cast mono element full body composite concrete with expose smooth finish, engrave lettering and with metal top cover with draining facility and varnish weatherproof coating with 12 MPa flexural strength and Compressive strengh of 40 MPa, UV resistant stabilise colour as per Architects choice including fixing SS 304 internal detachable bin, cleaning surfaces and including cost of loading -unloading and placing with crane.
86Providing and fixing rust free Galvanised chain link 10 guage 50x50 mm, including cutting, hoisting, fixing, painting with sponge all wastages in position at all heights as per EIC.(paint to be paid sepatrately.)
87Providing, installing and fabricrating fixed/portable BOXING RING as per standards having folding and dismantling approved by Boxing Federation of India and Sports Authority of India. The boxing ring will be made of 24 feet x 24 feet by six table GI structure of 12"x8" ft with details as mentioned here. (1) Corner pole 24"x24" ft. (2) 20"x20" ft rope to rope playing area. (3) 1mt ring height from ground level,. (4) Four ropes of 3.5" inch each thick covered with synthetic cover in white, blue and red color or P.V.C. white pipe. (5) Corner poles made of 4” pipe in white, blue and red color. (6) Laminated waterproof wooden planks of 8" x 3" and 8’x4’are used on the top of six tables. These planks make level of the floor equal & nice. (7)Total Wooden floor is covered with 3/4" (E.P.) Expended polythene foam. Then this foam is covered with waterproof canvas cover. (8) Four protection corner padding are used to cover corner poles to protect injury to player. (9) All four corner poles are attached with cross link tensioned wires with coupling tighter with each other diagonally. Funnel, tube, three stairs, basket etc are given with other accessories with boxing ring. The rate is incluvise of complete works.
88Providing and Installation of Football Goal post of size of 8" x 24 inches with heavy duty GI pole structure with around 5" inch dia with minimum 3 mm thickness with support as required. Hokes welded with back support. Back extension pipe of 44 mm dia MS GI tube with 2.5mm thickness. The structure to be powder coated with moving PU heavy duty wheels of 4 * 3 m rectabgle section thickness of 6 cord mm. The cost is incluvise of nylon net of brand Nevia with 4 side tape . All works complete as per instructions of EIC.
89Providing, supplying and installng on site Team Bench Frame made of metallic 2”X3” pipe with waterproof laminate floor, provision of transparent shed on back and sides. Portable and movable on wheels. Sizes to be provided for 12 ft. X 4 ft. The structure should included making of foudation if required at site and rust proof paint all complete as per direction of EIC.
90Providing, supplying and fixing of Volley ball Pole Made of 3" G.i pipe, with special system for net tightening, adjustable height 1. V.B.P- 3 (a) Fixed in Groundwith foundation. The height of the pole to be minimum 2.4 m as per standards.
91Providing, supplying and fixing of Volley ball net per Sports Authority of India standard of 1m wide and 9.5m-­10m long and 10 cm square mesh as per standards all complete. (make: Nivia)
92Designing, providing and fixing of Football theme metal art sculptures made from any metal scrap material includng flat bar iron, car metal parts, structural steel, reinforcement or any other metal scrap, bent and welded together by hand to create unique football player kicking the ball décor for outdoor locations. The sculpture should be landmark design continuous or separate sculptures together spanning 7m length and 3.6m height tentatively. All parts to be used from scrap should be free from dust and other foreign materials, well cleaned, sanding and if required dry abrasive blasting. The sculpture to be painted with minimum 2 coats of zinc oxide primer and 2 coast of anti-corrosive paint. The sculpture should be designed by well experienced artist in this field with experience in making sculptures from scrap earlier. The foundation for the same will be extra but the sculpture should be free standing without any hazard. All surface of the sculpture to not have any sharp edge or corners. The Contractor shall prepare shop drawing as per GFC drawing and as per actual site condition and design to be approved with EIC or architect before execution.
93Supplying and fixing reinforced concrete heavy duty non-pressure NP3 pipes with collars/without collars as per IS 458-1991 specifications including setting the pipes in ground for tree protection. 600 mm dia. As directed by EIC.
94Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water all complete.
95Supplying, stacking and spreading of good earth at site complete from the source approved by the engineer in charge including in layers of 20cm. thickness rolling, watering, ramming and consolidating, screening, loading, unloading, conveyance and stacking at site. etc complete as directed by Engineer in charge.
96Lawn plantion Selection-1: Providing including loading, unloading and Planting in rows 1 to 2 cm apart in either directionincluding watering, fertilizing and maintenance of the lawn till the grass form a thick lawn free from weeds and fit for mowing including supplying good earth if needed. Maintaining the grass in a presentable condition involving all the operations of de-weeding , application of chemical fertilizer, watering, mowing ,rolling etc. for the lawn the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and fine dressing and refilling with 150 mm of garden soil and farmyard manure (3:1 ratio) including supplying, stacking, mixing and spreading sludge / well decayed farm yard manure, application of required pesticides for anti termite treatment, by volumethe excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed, maintaining it for 5 years properly and weed free as per standards for football ground and other sports.
97Providing including loading, unloading and Planting saplings of plants/ trees (Planting of 2 m height and min. 20 cm girth healthy saplings) excavation of required size pit, in the proper beds as prepared and maintaining the same by involving all the operations like multing, de-weeding, hoeing, forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and fine dressing and refilling with garden soil and farmyard manure (3:1 ratio) including supplying, stacking, mixing and spreading sludge / well decayed farm yard manure, application of required pesticides for anti termite treatment, maintaining it for five years, by volumethe excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes min. 0.9 x 0.9 m and 0.9 m deep with required stacking.(a) Plumeria Red
98b) Delonix regia (Gulmahor)
99c) Azadirachta indica
100d) Tabebuia Rosea
101e) Neolamarckia cadamba (Kadamb)
102f) Mangifera indica (Kesar Mango)
103g) Bauhinia Varigated
104Providing including loading, unloading and Planting hedges/shrubs (min. 2"-3" height and girth size 8mm-12mm) approx 10-14 plants per sq mtrs, border plant, excavation of required size pit, in the proper beds as prepared and maintaining the same by involving all the operations like multing, de-weeding, hoeing, forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and fine dressing and refilling with garden soil and farmyard manure (3:1 ratio) including supplying, stacking, mixing and spreading sludge / well decayed farm yard manure, application of required pesticides for anti termite treatment, maintaining it for five years, by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed. Holes min. 0.30 x 0.30 m and 0.30 m deep with required stacking. a) Duranta Variegated
105b) Bougainvillea Variegated
106c) Ficus Panda
107d) Leucophyllum
108e) Dracaena Marginata
109f) Murraya Paniculata (Madhukamini)
110g) Chandni Shrichakra
111h) Croton Lemon
112i) Croton Variegated
113j) Jatropha Red
114k) Tecoma Gaudichaudi
115l) Stachyterpheta Blue
116m) Nerium Oleander
117n) Raphis Palm
118o) Cestrum Nocturnum
119Providing including loading, unloading and Planting ground covers (min. 6" height and girth size 5mm-8mm) approx 10-14 plants per sq mtrs, border plant, excavation of required size pit, in the proper beds as prepared and maintaining the same by involving all the operations like multing, de-weeding, hoeing, forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following plants the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and fine dressing and refilling with garden soil and farmyard manure (3:1 ratio) including supplying, stacking, mixing and spreading sludge / well decayed farm yard manure, application of required pesticides for anti termite treatment, maintaining it for five years, by volumethe excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed. Holes min. 0.20 x 0.20 m and 0.30 m deep with required stacking.a) Purple Heart
120b) Vadelia
121c) Pandanaus Variegated
122Clearing and grubbing road land including uprooting rank vegetation grass bushes,shrubs,sapling and trees girth up to 300 mm removal of stumps of trees cut earlier and disposal of unserviceable materials (C)By mechanical means in area of light jungle
123Demolition including stacking of serviceable material and disposal of unserviceable materials with all lead and lift.(i) R.C.C. work/Road works
124Demolition and disposal of unserviceable materials with all leads and lift. (ii) unreinforced cement concrete / Pavements / rubble
125Demolition of Brick Work/AAC block work/ Stone wall with plastered surface/ wall dedo including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.
126Dismentling steel work including distempering and stacking the materials with all lead and lift.
127Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyond 30 cm girth upto and including 60 cm girth.
128Point wiring for Light / Bell with2-1.5 sq.mm& earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type ofpipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuityof following type, erected on PVC / Metallic box, single mounting base framecovered with textured/metallic front plate modules erected on /in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories. Cat. III
129Point wiring for secondary light point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type ofpipe to be erected concealed in / flushed on wall/ceiling,complete with earth continuity and necessary connection with primary light with accessories erected onMetal /PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheetfor open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
130Point wiring for FAN with 2-1.5 sq.mm& earthwire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV GradeFRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling complete with 6A Modular type switch and hum free EME four or more step type electronic fan regulator with separately mounted andaccessories with earth continuity of following type erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories. Cat. III
131Point wiring for Individual Plug with& earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plugerected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [I] For 6A Plug with 2-1.5 sq.mm Cu. Wire. (a) with medium class Rigid PVC pipe and accessories. Cat. III
132[II] For 16A Plug with 2-2.5 sq.mm Cu. Wire - As per description 1.2.3. (a) with medium class Rigid PVC pipe and accessories. Cat. III
133[III] For 20A Plug with 2-4 sq.mm Cu. Wire - As per description 1.2.3. (a) with medium class Rigid PVC pipe and accessories. CAT-III
134Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erectedon/ in wall / ceiling with following type accessories. Cat-III
135Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erectedwith necessary connection. As desired by Engineer In charge. (4) TV Co-axial Socket outlet - As per description 1.2.6. Cat-III
136(7) Blank Plate Single - As per description 1.2.6. cat-III
137(10) 6/16Amp. Universal socket - As per description 1.2.6. Cat-III
138Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceilingerected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed. (a) 20 mm
139(b) 25 mm - As per description 1.3.2
140(c) 32 mm - As per description 1.3.2
141Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes. (1) 20 mm
142(2) 25 mm - As per description 1.3.4
143[C] G.I. Junction cross over box for metal / Al. trunking with duct entry 25mm x 38mm size having epoxy powder coated trap lead with corrosion & rust free having load bearing capacity of 3.6 TONS with adjustable levelling screw of following size. [1] 150mm x 150mm x 60/75 mm depth
144[2] 250mm x 250mm x 60/75 mm depth - As per description 1.3.10
145Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipeto be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size. (a) with medium class Rigid PVC pipe and accessories. (a) 2 wire 1.5 sq. mm
146(b) 2 wire 2.5 sq. mm - As per description 1.4.1
147Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size. (a) with medium class Rigid PVC pipe and accessories. a. 2 wire 4 sq. mm
148Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. b).RG-6
149Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be erected as directed of following size. (E)3 core 2.5 Sq. mm
150(K) 4 core 4 Sq. mm-As per description 4.2.1
151Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables. (B) 3 core 4.0 Sq. mm
152(C) 3 core 6 Sq. mm- As per description 4.3.2
153Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables. (A-1) 3 1/2core 35 Sq. mm ( 16 Sq. mm 1/2 core)
154(C) 3 1/2 core 70 Sq.mm (35 Sq.mm 1/2 core) - As per description 4.3.3
155(D) 3 1/2 core 95 Sqmm (50 Sq.mm1/2 core) - As per description 4.3.3
156(E) 3 1/2core 120 Sq. mm (70Sq. mm 1/2 core) -As per description 4.3.3
157Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables. (b) 4 core 6 Sq. Mm
158(c) 4 core 10 Sq. mm
159(d) 4 core 16 Sq. mm - As per description 4.3.4
160(e) 4 core 25 Sq. mm - As per description 4.3.4
161Supplyingfollowing size of Lightduty “A” Class G.I . Pipe & erecting as directedby Engineer-in-charge. (b) 50 mm dia
162Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (a) 2 to 4 core 4 Sq. Mm
163(b) 2 to 4 core 6 Sq. Mm
164(c) 2 to 4 core 10 Sq. mm - As per description 4.6.1
165(d) 2 to 4 core 16 Sq. mm - As per description 4.6.1
166(e) 2 to 4 core 25 Sq. mm - As per description 4.6.1
167Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (B) 3 & 1/2core 35/50 Sq. mm - As per description 4.6.3
168(C) 3 & 1/2 core 70 Sq. mm - As per description 4.6.3
169(E) 3& 1/2 core 120 Sq. mm - As per description 4.6.3
170Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 1.5/ 2.5/4/6 Sq.mm
171(B) 10 Sq.mm- as per description 4.7.1
172(C) 16 Sq.mm. - as per description 4.7.1
173(D) 25 Sq.mm. - as per description 4.7.1
174(E) 35/50 Sq.mm. - as per description 4.7.1
175(F) 70 Sq.mm. - as per description 4.7.1
176(H) 120 Sq.mm.- as per description 4.7.1
177Lowering, laying and jointing HDPE pipes and specials (By butt fusion welding method) including cost of conveyance from stores to site of works at all level including cost of labour, material. (1) 50mm dia
178(3) 75mm dia
179Lowering, laying and jointing HDPE pipes and specials (By butt fusion welding method) including cost of conveyance from stores to site of works at all level including cost of labour, material. (1) 110mm dia
180(4) 160mm dia
181Providing and supplying in standard length ISI mark high density Polyethylene H.D.P.E. Pipes of size HDPE PE100 PN10 as per IS-4984/2016. 6kg/cm2. Suitable for underground cable duct ,including of Couplers and endcaps. (1) 50mm dia
182Providing and supplying in standard length ISI mark high density Polyethylene H.D.P.E. Pipes of size HDPE PE100 PN10 as per IS-4984/2016. 6kg/cm2. Suitable for underground cable duct ,including of Couplers and endcaps. (2) 75mm dia
183(4) 110mm dia
184(7) 160mm dia
185Excavation for pipe line trenches for electrical line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified. (a) in all sorts of soil and soft murrum. upto 1.5m depth
186Construction of Manhole chambers 600mm X 600 mm and depth 1.0 m in brick or bela stone masonry, locally available in C. M. 1:6. Foundation concrete 150 mm thick in C. C. 1:4:8 of trap metal size 25 mm to 40 mm thick, inside cement plaster in C. M. 1:3 and cement pointing outside in C. M. 1:3 and top cover of precast RCC slab 100 mm thick (with key hole in two parts, each with handles or MS Bar etc. complete as given size) Upto 1 Mt. depth from G. L. to pipe invert level incl. complete civil works but excl. cost of excavation and refilling, with cast in situ RCC slab in one single piece with fixing of CI-MH Frame and cover (excl. cost of CI-MH Frame and cover) with 23 mm thick brick masonry wall in C.M.1:6. With precast slab in two parts 15mm.
187Providing and fixing of 600mmx600mm recessed FRP manhole covers for 25tonnage capacity including frame with key hole and all required fittings and accessorries.
188Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark. Cat-III
189Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used). (A-ii) Single phase 6way SS Double door
190(A-iv) Single phase 12 way SS Double door- as per description 3.11.5
191Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. ratingerected as directed. (I) 25 Amps. DP-CAT-III
192(ii) 40Amps. DPCat-III
193Providing and erecting metallic vetrified danger notice board for MEDIUM VOLTAGE installation to be erected as per I.S
194Providing and erecting required size HOT deep Galvanised strip for earthing of H.T. OCB/ ACB/ Transformer LT pannel board, Motors etc. using copper clamp.
195Providing and erecting HOT deep Galvanised strip iron wire 8 to 16 S.W.G.
196Supplying & erecting in earthpit of minimum bore dia. 225mm size ASH orapproved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipeshaving Outer pipedia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. [B] For Electrical installation up to 11 KV. located in other than normal soil i.e. Soft Rock, Marshy Soil etc. Length of Pipe : 2 mtr. -Back filling Compound :1 no. Bag of 25Kg.
197[C] For Electrical Installation covering Transformer Neutrals, Lightningarrester Earthing, A.C.Plant & Sensitive Computer System(likeAutomation,SCADA)i.e. independent Earthing located in other than normal soil i.e.Soft Rock,Marshy Soil etc. - As per description 3.14.10. -Length of Pipe : 3 Mtrs. -Back filling Compound :2 nosBags of 25 Kg. -as per description 3.14.10
198Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor typecubical panel board having IP-54 protection made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary supporting angles, flats including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, with suitable size of inter connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses for measuringinstruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket complete. The Panel shall be painted with epoxy powder coating. (The rates excludes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips,meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be supplied with following approved manufacturers with following size. (A) The standard companies switch gear shall be used and only manufacturers at CPRI approved factory and shall be certified by that company whose switch gears are used after fabrication for beneficial use.(i) with 350mm depth
199Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comporised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transperent cover erected as required with necessary connection.
200Providing and erecting AC-3 duty 3 pole power contactor with 2 NO & 2 NC aux contacts complete with 415V/220V operating coil suitable for - 40 amp. ( Dinrail mounted & DB mounted only of Legrand make.)
201SITC of32A TP MCB, 10kA Short Circuit Breaking Capacity, ‘C’ curve.Make: Havell"s, Legrand, Schneider
202SITC of Panels of below ratings as per IS Specifications and respective drawings. The unit rate for each item shall include :Call for final inspection prior to dispatch. Delivery of the panels to site. Shifting of the panels from site store to the suitable location. Fixing of Shipping Section. Assembly and wiring of component supplied separately. Installation of panel to Electric Room including removing packing. Earthing all components, frame etc. to a common internal earth bar. M.S. parts should be painted with powder coating. Supply & Fixing all accessories and supporting structure. Supply & Fixing of M.100 mm. channels for fixing the panels. Connection, Testing & Commissioning. Checking of Internal connection and wiring, operation of switches, starter, TPN MCCB, relays, contractors etc. Supply of necessary tools, hardware, mounting with necessary civil masonary works etc.Electrical Contractor shall carry out the insulation test at site and all the observations shall be recoreded and submitted in duplicate to the consultant or engineer - in - charge. The rate shall include the civil foundation as approved by site enginner. Make: Schnieder, ABB, Siemense, L&T. SITC of Indoor type Main LT Panel-1 (Electrical Room) as per above specifications. Incomer : 160A, FP MCCB. Busbar: 160A TPN, 415V,3-Phase 15KA Al. RYB, On, Off, Trip Indicating Lamp-6 NOS with VSS & Voltmer. Control Fuse - 3 NOS. MFM - 1 NO. CT 160/5A 3 NOS (for Measuring Current) with ASS & Ammeter. CT 160/5A 3 NOS (for APFC Relay). 1no. 160A FP ATS (auto transfer switch). Buscoupler : 160A, TPN Microprocessor Based 36KA, MCCB.Outgoings : 1no. 80A FP MCCB, 1no. 63A FP MCCB, 3nos. 40A FP MCB, 2nos. 63A FP MCB, 2nos. 40A FP MCB, 1nos. 25A FP MCB. 3nos. 16A DP MSBs. 2no. 32A TP MCB. 2no. 25A DP MCBs. Contractor must consider 20KVAR capacitor bank inside the main panel. All MCCBs must be microprocessor based. NOTE: Panel design might vary as per final working. Contractor must follow the SLD before execution.
203SITC of Outdoor type Feeder Section Panel-1 (Near Sports Facility) as per above specifications. Incomer : 80A, FP MCCB. Busbar: 80A TPN, 415V,3-Phase 15KA Al. RYB, On, Off, Trip Indicating Lamp-6 NOS with VSS & Voltmer. Control Fuse - 3 NOS. MFM - 1 NO. CT 80/5A 3 NOS (for Measuring Current) with ASS & Ammeter. Outgoings : 3no. 40A FP MCB, 1nos. 10A DP MCB, 1nos. 63A FP MCB, 1nos. 32A TP MCB, 2nos. 25A DP MCB. All MCCBs must be microprocessor based. NOTE: Panel design might vary as per final working. Contractor must follow the SLD before execution.
204SITC of Outdoor type Feeder Section Panel-2 (Near Table Tennis Block) as per above specifications. Incomer : 63A, FP MCCB. Busbar: 63A TPN, 415V,3-Phase 15KA Al. RYB, On, Off, Trip Indicating Lamp-6 NOS with VSS & Voltmer. Control Fuse - 3 NOS. MFM - 1 NO. CT 63/5A 3 NOS (for Measuring Current) with ASS & Ammeter. Outgoings : 1no. 40A FP MCB, 1nos. 25A FP MCB, 1nos. 63A FP MCB, 1nos. 32A TP MCB, 1No. 10A DP MCB. 2nos. 25A DP MCB. All MCCBs must be microprocessor based. NOTE: Panel design might vary as per final working. Contractor must follow the SLD before execution.
205Providing and erecting Approved make Ceiling fan with double ball bearingISI mark with condenser A.C. 23OV.50 c/s.1200 mm. sweep complete, canopy and 30 cms. down rod erected on existing hook or clamp with 24/0.2 , 3 core flexible wire with earthing. [Make shall be approved by Engineer in charge]
206Providing 2.5mm.thick laminated sheet to cover the fan hook or Fan box.
207Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM. [A] 305 mm dia 900 RPM. Cat-II
208Supplying & erecting electro galvanised G.I. wire micro mesh jali cover of grade 304 required size with suitable wooden frame duly fitted in wall outside of exhaust fan for insect protection.
209Supplying and erecting approved make oscillating type bracket fan A.C. 23OV. 50cy/s 400/450 mm sweep wall mounted with height adjustment and rotary tilting device complete with guard,flexible Core plug top complete erected with lead wires as directed. Cat-II
210Providingand fixing approved make Octagonal poles. Made from CR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/4759.with required base plate suitable suspend local wind speed to be erected on existing foundation. (B) 4 Mtr. Long 70 mm TopX 130 mm bottom dia, 3 mm thickness
211(E) 7 Mtr. Long 70 mm TopX 135 mm bottom dia, 3 mm thickness with all required fabrication suitable to mount 6nos. 120 to 240watt led flood light.
212Pole base suitable forfollowing size of pole fabricated from 4 mm. Thick M.S. sheet with M.S.door having two hinges welded on M.S. flat 25 x 3 mm which is fitted on M.S..base by bolts welded inside the pole base erected with one coat of Red oxide and two coats of Aluminium paint. Outside dimension as per SOR. drawing. (a) Suitable for 90 mm. dia.base of pole
213Providing M-20 / 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 45 x 45 x 100 cms. Deep in below ground level with plinth of 45 cms x 45 cms (or 45 cms dia x 45 cms) high upper ground level with necessary curing and finishing in approved manner. ( for 4 & 6 mtr pole)
214Providing M-20 / 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 60 x 60 x 120 cms. Deep in below ground level with plinth of 45 cms x 45 cms(or 45 cms dia x 45 cms) high upper ground level with necessary curing and finishing in approved manner. ( for 7.5 & 8/8.5 mtr pole)
215Providing & erecting approved make street light / wall mounting junction box compression moulded from DMC (thermoset plastic) vertical sliding cover having locking with square head stud loop in / loop out in built terminal suitable for four core cable, waterproof of I.P. 54 protected with clamp or bolt nut & earth bolt of following size. [B] 250mm x 194mm x 99 mm
216Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA polyester powder coated and high U.V. & corrosion resistancewith diffuser and/or Polycarbonate optics with company mark/name. 120 to 300 V,Power Factor more than 0.9, THD < 10 %, CCT4000 K to 6500K, Uniformity ratio >0.7, Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 %. CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/Bridgelux(U.S.A.) make LED used for luminaire. (Each fitting required LM-79 & LM-80 Certificates). (A) Tube Light with integral/ non-integral driver. (d) 20-22 Watts, Surge - 4KV,IP-20,4 feet. Cat-III
217(C) Square/ Circular, Surface/Recessed Mounted Downlight with provision for spring loaded mounting clips complete. (b) 10-15 watts, Surge-4 KV. Cat-III - as per description 14.01
218(c) 20-24 watts, Surge-4 KV- as per description 14.01©
219Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA polyester powder coated and high U.V. & corrosion resistancewith diffuser and/or Polycarbonate optics with company mark/name. 120 to 300 V,Power Factor more than 0.9, THD < 10 %, CCT4000 K to 6500K, Uniformity ratio >0.7, Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 %. CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/Bridgelux(U.S.A.) make LED used for luminaire. (Each fitting required LM-79 & LM-80 Certificates). (A) Tube Light with integral/ non-integral driver. (d) 12-15 Watts, Surge - 4KV,IP-20,2 feet. Cat-III
220Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 1Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses with company mark/name engraved or embossed 120 to 300 V,Power Factor more than 0.95, THD < 10 %, CCT5000 K to 5700K, Uniformity ratio >0.45, Luminaire efficacy> 85 lumens/watt . LED driver efficiency > 85 %. CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/ BridgeLux (U.S.A.) make LED used for luminaire. ( Each fittings required LM-79 & LM-80 certificates). (B) Flood Light (IP-65), Surge -4KV. (d) above 100 to 120 watts. Cat-III
221Supplying and erecting LED Flood light fittings with High power White LEDs wattage above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses with company mark/name engraved or embossed 120 to 300 V,Power Factor more than 0.95, THD < 10 %, CCT5000 K to 5700K, Uniformity ratio >0.45, Luminaire efficacy> 85 lumens/watt . LED driver efficiency > 85 %. CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/ BridgeLux (U.S.A.) make LED used for luminaire. ( Each fittings required LM-79 & LM-80 certificates). (B) Flood Light (IP-65), Surge -4KV. (e) above 150 to 240 watts. Cat-III
222SITC of IP66, IK07, 30W LED (4000K) Traditional type U-shape single arm type decorative light fixture without pole. To be fixed on existing fabricated coumpond wall with all reauired cable connection and junction box including following specifications:Die cast EN-AB-47100 aluminium housing with high corrosion resistance. Stainless steel screws. Clear toughned glass 6mm thick. Luminaire with single cable entry and gormmet. Silicon gasket. Double powder paint. 150mm dia base plate with necessary bolts and fittings. Buried in ground upto 600mm depth. Powder coated as per approved colour with weather proof coat. All required cable connection with suitable MCB mounting inside the pole. 4000K CRI80 3360lm. Rated Luminaire luminous fluux 1721lm. Rated input power 60W, 220V-240V AC 50/60 HZ. Make: Disano, Neri, Kesselec, Klite. Contractor must submit the sample to the consultant/architect or engineer incharge before execution. Fixture warranty must be 3 years minimum.
223SITC of IP66, IK07, 40W LED (4000K) traditional type post top lantern type decorative light fixture with 4 Mtr. die cast aluminium pole of 100mm Dia. including following specifications:Die cast EN-AB-47100 aluminium housing with high corrosion resistance. Stainless steel screws. Clear toughned glass 6mm thick. Luminaire with single cable entry and gormmet. Silicon gasket. Double powder paint. 150mm dia base plate with necessary bolts and fittings. Buried in ground upto 600mm depth. Powder coated as per approved colour with weather proof coat. All required cable connection with suitable MCB mounting inside the pole. 4000K CRI80 3360lm. Rated Luminaire luminous fluux 1721lm. Rated input power 40W, 220V-240V AC 50/60 HZ. Make: Disano, Neri, Kesselec, Klite. Contractor must submit the sample to the consultant/architect or engineer incharge before execution. Fixture warranty must be 3 years minimum.
224SITC of IP66, IK06, 12W LED Uplighter (spike/bracket type) with following specifications. 4000K. Luminaire housing & bracket made of die cast aluminium, aluminium & SS fasteners. Clear tempered safety glass. Mounting earth spike or die-cast bracket arrangement to facilitate easy installation at any desired location. Swivel range of the luminaire in the horizontal axis 0°-90°. Luminaire supplied with one metre cable length and a IP67 connector. Silicone gasket. Cable entries for through-wiring of mains supply cable. Integral constant current power supply. CRI ( Ra) : =80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Contractor has to make 300mmx150mm deep or higher rcc foundation for spike/bracket fixing. Make: Dissano, Neri, Klite. Contractor must submit the sample to the consultant/architect or engineer incharge before execution. Fixture warranty must be 3 years minimum.
225SITC of IP66, IK06, 6W LED Uplighter (spike/bracket type) with following specifications. 4000K. Luminaire housing & bracket made of die cast aluminium, aluminium & SS fasteners. Clear tempered safety glass. Mounting earth spike or die-cast bracket arrangement to facilitate easy installation at any desired location. Swivel range of the luminaire in the horizontal axis 0°-90°. Luminaire supplied with one metre cable length and a IP67 connector. Silicone gasket. Cable entries for through-wiring of mains supply cable. Integral constant current power supply. CRI ( Ra) : =80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Contractor has to make 300mmx150mm deep or higher rcc foundation for spike/bracket fixing. Make: Dissano, Neri, Klite. Contractor must submit the sample to the consultant/architect or engineer incharge before execution. Fixture warranty must be 3 years minimum.
226SITC of IP67, IK08, corrosion resistant 18W LED Asymmetrical Ground Burial type light fixture with following specifications. 4000K. Luminaire made up of die-casting dark grey powder coated aluminium, corrosion resistance with low copper content. Hard chromeplated stainless steel 316 grade front ring. Silicone seal gasket. Stainless steel screws. Step tempered glass of 7mm thickness with static load resistance of 1704 kgs. Optical reflector effeciency =85%. Luminaire hard wired with 3 x 1.0mm2 cable of 0.5mts length. Supplied with mounting sleeve for preparing recessed opening in ground. Integral power supply. Earth connection. Safety class I. Make: Neri, Ligman, K-lite. Contractor must submit the sample to the consultant/architect or engineer incharge before execution. Fixture warranty must be 3 years minimum.
227SITC of IP65, IK07, weather proof & corrosion resistant 12W LED Wall Down Light type fixture with following specifications. Square/Cylindrical Shape, open surface, medim wide beam angle with symmetrical distribution, 3000k. Die-cast aluminium housing. Stainless steel fasteners in grade 316. Durable silicone rubber gasket. High efficiency optical reflector. Clear toughened glass. Single cable entry. Housing is treated with a chemical chromatised protection before powder coating, ensuring high corrosion resistance. Fixture colour must be as per consultant/architect"s approval. Make: Ligman, Neri, K-lite, Uniled. Contractor must submit the sample to the consultant/ architect before execution. Fixture warranty must be 3 years minimum.
228SITC of IP65, IK08, 24W LED Open Surface Mounted Bulkhead type Light fixture with following specifications. Shielded, 3000k, Corrosion resistant die-cast aluminium frame and body. Stainless steel fasteners in grade 316. Durable silicone rubber gasket. Impact resistant UV stabilised polycarbonate diffuser. The luminaire is treated with a chemical, chromatised protection before powder coating, ensuring high corrosion resistance. Make: Ligman, Neri, K-lite, Uniled. Contractor must submit the sample to the consultant/architect or engineer incharge before execution. Fixture warranty must be 3 years minimum.
229SITC of IP65, outdoor, open surface 12W round cylindrical down light type fixture with all required accessories. 4000K.Luminaire made of die cast aluminium, aluminium & SS fasteners. Clear tempered glass. Silicone gasket. Hybrid optics with lens & reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Cast aluminium plate for surface mounting onto the ceiling. Surface mounting on ceiling using hardware after connecting to the power supply. Cable entries for through-wiring of mains supply cable. Integral constant current power supply. CRI ( Ra) : =80 ( 90 CRI - On Request ). Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Make: Ligman, Neri, K-lite, Uniled, Abby. Contractor must submit the sample to the consultant/architect or engineer incharge before execution. Fixture warranty must be 3 years minimum.
230Supply, Installation, Testing & Commissioning ofIP Network IR Dome Camera, 1/2.8" CMOS, 2 MP, Min. Illumination required 0.05lux F1.4 color, 0Lux F1.4(IR on), 120dB True WDR, Min. Pixels 1920 × 1080, min. dual stream,2.7–12 mm motorized focus & zoom lens, BLC, HLC, 3DNR, Privacy Mask, IR LEDs Smart IR with upto 30m IR distance, 128GB SD card support, H.265, H.264 High Profile and MJPEG, PoE Class 3 and 12V DC, IP 66, IK10 rated vandal resisntant, Having Operating temp range : –30°C to 60° C. ONVIF Profile, cyber secured, UL, CE, FCC & RoHS certified. Approved Makes: Bosch, Axis, Honeywell, Avigilon
231Supply, Installation, Testing & Commissioning ofIP Network IR Bullet Camera, 1/2.8" CMOS, 2 MP, Min. Illumination required 0.05lux F1.4 color, 0Lux F1.4(IR on), 120dB True WDR, Min. Pixels 1920 × 1080, min. dual stream,2.7–12 mm motorized focus & zoom lens, BLC, HLC, 3DNR, Privacy Mask, IR LEDs Smart IR with upto 60m IR distance, 128GB SD card support, H.265, H.264 High Profile and MJPEG, PoE Class 3 and 12V DC, IP 66, Metal Body, Having Operating temp range : –30°C to 60° C. ONVIF Profile, cyber secured, UL, CE, FCC & RoHS certified. Approved Makes: Bosch, Axis, Honeywell, Avigilon
232Supply, Installation, Testing and Commissioning  of 16 Channel NVR with 8 SATA, with 1080pRealtime Live View H.265/H.264 MJPEG dual codec decoding Up to 12 MP resolution preview & playback Max 320 Mbps incoming bandwidth support 8 SATA HDDs up to 64TB, Supports fisheye videode-warping in local and web user interface,Supports visual or auditory notifications(a flashing light, bell,or siren) ONVIF compliant, UL, CE, FCC and & RoHS compliant. Approved Makes: Bosch, Axis, Honeywell, Avigilon
233Supply, Installation, Testing and Commissioning  of 12 TB HDD for Storage. Approved Makes: Segate / WD
234Supply, Installation, Testing And Commissioning of Layer 2 Managed Gigabit POE switch with 24 # 10/100/1000BaseT ports and 2 # Gigabit Combo ports(RJ45/SFP), 2 # Gigabit SFP Port. Approved Make: HP/ Cisco
235Supply, Installation, Testing and Commissioning  of UTP CAT6 LSZH cable in PVC conduits / pipes / raceway. Approved Make: Polycab/Tyco/Molex
236Supply, Installation, Testing and Commissioning  of AT6 UTP RJ-45 LSZH Patch Cords Solid Conductor 3ft for data. Approved Make: Polycab/ Tyco/ Molex
237Supply, Installation, Testing and Commissioning  of 4U Wall Mounting Rack for Floor Distribution. Approved Make: Tata/APW/Valrack
238Supply, Installation, Testing and Commissioning  of 6Core Fiber Cable for Building Connectivity. Approved Make: Polycab/Tyco/Molex/CIS
239Supply, installation, Testing & Commissioining of 24 Port fully loaded patch panel
240Supply, Installation, Testing And Commissioning of Layer 2 Managed Gigabit Non-POE switch with 24 # 10/100/1000BaseT ports and 2 # Gigabit Combo ports(RJ45/SFP), 2 # Gigabit SFP Port. Approved Make: HP/Cisco
241Supply, Installation, Testing and Commissioning  of Caller ID Telephone Instruments
242Liaison fees for preparing necessary documents and drawings for getting N.O.C from Electricity Co. and Electrical Inspector for the installation of 11 KV / 0.433 KV Electrical L.T distribution sub stations. (All statutory fees will be paid by client)
243Supplyingand erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger, static Inverter & sealed maintenance free batteries. The charger having operating capacity for input 160-270V AC &inverter having output23OV,5O Hz Acwith 0.8 load power factor with battery, overunder voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following capacity & with Following size of batteries. (D) 5 KVA (i)With 16 Nos. of 12 V 55 Ah SMF batteries, BIS certified
244Supplying and erecting, commissioning and testing Diesel Generating set 82.5KVA having continuous rating, 3 phase, 415 volts, 50 cycles A.C. supply comprising of a totally enclosed air/water cooled diesel engine with multi-cylinders developing suitable BHP not less than following capacityat 1500 RPM with 10% overload for one hour in 24 hours with standard accessories like fly wheel, lubricating oil cooler, "A" class governor, heavy duty fuel wheel and lubricating oil filter, oil bath air filler, lubricating oil pressure gauge, end exhaust manifold, standard set of tools with adjustable spanners, screw drivers, feeder gauge, cylinder head to cover, joint cylinder head to exhaust, element lube oil filter, 12/24 volts electric starting equipment complete with standard battery, dynamo, cut-outs, ammeter, necessary wiring, pressure gauge, starter etc and heavy duty Residential type exhaust silencer and vertical hot air duct both. logged with asbestos rope, save oil trays, exhaust piping of required length, standard wall/floor mounted fuel with level indicator and piping anddrip proof alternator, self excited, self regulated, screen protected, with excitation system, capable of delivering the rated system output at 415 volts, 3 phase, 0.8 PF, 50 Hz, 4 wire, running at 1500 RPM, conforming to IS-4722- 1968 with voltage regulation+/- 5% of rated voltage from no load to full load. Both the engine and alternator fitted on a common fabricated steel base plate with antivibration mounting engineand alternator both connected to each other by flexible flange coupling and with floor/wall mounted control panel box comprisingof voltmeter ammeter, selector switches, ACB / MCCB / MCB of adequate capacity, indicator lamps duly wired with HRC fuses. The alternator & control panel shall be connected with provided suitable capacity armoured cable and complete with Acoustic enclosure (canopy) made out of 18 SWG CRCA Sheet, sound absorbing material Rockwool of 64 density & 100 mm thick conforming to IS:8183 The resin bonded rockwool covered from inside the canopy by perforated sheet with 3/4 mm holes, sound level not more than 75 dB at a distance of 1 mtr, as per PVCT norms. Erection, commissioning and satisfactory testing as per requirement with first filling of fuel, oil, etc. with guarantee of complete system for One year. & with obtaining all necessary certificate from Electrical Inspector. The Capacity and Ratings of DG sets are as below. (J) Continuous rating of 82.5 KVA ,BHP not less than 102 BHP
245Providing & erecting approved make AMF control panel suitable for following size of3 phase, 415 V., 50 cycles, A.C. diesel generating set complete of scope as detailed below: 1) Power module:A pair of electromechanically interlocked contactors (for mains & generator) Overload relay for generator contactor Neutral contactor for mains and generator Power socket for connections.2) Control and metering module: Line voltage monitor. Generator voltage monitor Ammeter 3 items attempt start facility. Air circuit breakers/MCB/MCCB of suitable rating for auto/ manual operation. Auto/manual switch. Emergency stop push buttons. Manual start push button. frequency meter. Engine hour meter. Two earthing studs. 3) Protection module: The engine shutdown in the unlikely event of Low lube oil pressure High cylinder head temperature. V belt failure. 4) Indicators with alarm Load on generator. 5) Indicators Load on mains Engine fails to start . Emergency stop battery charger. The AMF Panel of following capacity. AMF Control Panel forAMF Control Panel for75 KVA/82.5 KVA3 phase DG Set
246Supplying and erecting Acoustic enclosure (canopy) made out of 18 SWG, CRCA Sheet, sound absorbing material Rockwool of 64 density & 100 mm thick conforming to IS:8183 The resin bonded Rockwool covered from inside level not more than 75 dB at a distance of 1 mtr, as PVCT norms ,on provided foundation suitable for following size of DG Set. The enclosures for following capacity of DG sets.For for 75 KVA to 82.5 KVA, 100/125/140 KVA
247Supplying & erecting D.C.P. type fire extinguisher for following capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets confirming to IS 2171 1985 and complete erected with necessary clamps made from 50 x 6 mm M S Flat with nuts and bolts grouted in wall complete. [A] For 5 Kg Capacity
248Supplying & erecting ABC powder type "Ceasefire" type Fire extinguisher as per IS 13849 or 1 Kg capacity with necessary clamp for erection on wall
249Providing and fixing wsh down water closet with concealed cistern including all fittings and accessories like bracket frame, dual flush face plate etc. (European type, W.C. Pan) with integral P or S trap including jointing the trap with soil pipe in Cement Mortar 1:1 (1-Cement : 1-fine sand) (Seal and cover to be measured and paid for separately)(A) vitreous China Pattern :(i) in white colour including all accessories and connections. Make: Jaquar, Kohler, Grohe, Cera high end series.
250Providing and fixing under counter washbasin with single hole for pillar tap with C.I. or M.S. brackets painted white including sutting holes and making good the same but excluding fittings.(A) Vitreous China:(ii) Flat Back washbasin 550 mm x v400mm size. (i) In white colour including all required accessories and connections like bottle trap, waste etc.Make: Jaquar, Kohler, Grohe, Cera high end series.
251Providing and fixing 600mm x 450mm bevelled edge mirrror of superior glass mounted on 6mm thick A.C. sheet or plywood sheet and fixing to wooden pluge with C.P. brass screws and washers.
252Providing and fixing stainless steel toilet paper holder.Make: Jaquar, Kohler, Grohe, Cera high end series.
253Providing and fixing screw down bib taps of following size.(B) Brasschromiumplated screws down Bib Tap including all required accessories and connections. (i) 15mm dia. Make: Jaquar, Kohler, Grohe, Cera high end series.
254Providing and fixing pillar tap, capstanhead, screw down high pressure with screws, shanks and back nuts. including all required accessories and connections. (i) 15mm dia.Make: Jaquar, Kohler, Grohe, Cera high end series.
255Providing and fixing Urinal of approved quality including connection with trap and with integral longitudinal flush pipe.(A) Squatingplate patternwhite earthenware 550mm x 300mm. including all required accessories and connections.Make: Jaquar, Kohler, Grohe, Cera high end series.
256Providing and fixing of Urinal Partition of 900mmx450mm, frosted glass with ss hardware fittings and screws.
257Providing and fixing C.P. ss towel rail comlete with C.P. brass/ ss brackets fixed to wooden plugs with C.P. brass/ ss scews.(B) 600mm x 20mm size.
258Providing and fixing screw down 2-way bib cock of following size. Brass chromium plated 2-way bib cock (i) 15 mm.(Make: Hind ware/cera/jaquar/Grohe) including health faucet, 1.2 mtr long pvc tube and walk hook with all required accessories and connections. Make: Jaquar, Kohler, Grohe, Cera high end series.
259Supply, installation, testing and commissioning of auto closing concealed push button for urinal flushing with all required accessories and fitting. Make: Jaquar, Kohler, Grohe, Cera high end series.
260Supply, installation, testing and commissioning of brass chromium plated 4way shower diverter, spout with hand shower provision & 6inch dia wall fixed shower 15/20mm including all fittings, accessories and connections. Make: Jaquar, Grohe, Hindware, Kohler, Cera
261Providing and fixing Angle tap, capstanhead, screw down high pressure with screws, shanks and back nuts.(i) 15mm dia.(Make: Hind ware/cera/jaquar/Grohe) including all required accessories and connections. Make: Jaquar, Kohler, Grohe, Cera high end series.
262Providing and fixing 450mm Long Braided Hose pipe with M10X1 Nipple, 15mm Nut, O-Ring & Rubber Washer (Suitable for Wash Basin, Kitchen Sink etc.) of approved make and conforming toManufacturers Standards. Make: Jaquar, Kohler, Grohe, Cera high end series.
263Supply, storing, installation and testing twin coat hook, fixed to wall / door with concealed CP screws etc. complete. Make: Jaquar, Kohler, Grohe, Hindware, Cera high end series.
264Providing and fixing of grab bars 300 mm Stainless steel in physically disabled toilet including all necessary fitting, SS Screws & Accessories etc.Complted in all manners and satisfied to of EIC.complete. Make: Jaquar, Kohler, Grohe, Hindware, Cera high end series.
265Providing and fixing of grab bars Vertical Swing 18-8 S, type-304, 18-gauge (1mm) stainless steel tubing with satin-finish. 1–1/4 (25mm) outside diameter wall mounted in physically disabled toilet including all necessary fitting, SS Screws & Accessories etc.Complted in all manners and satisfied to of EIC.complete. Make: Jaquar, Kohler, Grohe, Hindware, Cera high end series.
266Providing and Fixing of Stainless Steel Hand Dryer with all required connections and following specifications. Weld-free cover fixed to the base with two safety screws and lock withspecial speedflow key. Aluminium base. Includes silent-blocks to damp mechanical vibrations. Fire resistant plastic UL 94-V0 fan scroll. High-speed motor with safety thermal cut-off.The motor revolutions canbe adjusted manually by the potentiometer. • Aluminium centrifugal double asymmetrical inlet fan wheel. Disconnects automatically after 60 seconds of continuous use. Electronic infrared detection sensor. Adjustable detection by potentiometer(5- 25 cm). Ultra-flat: 10 cm deep (complies with ADA regulations). complete. Make: Jaquar, Kohler, Grohe, Hindware, Cera high end series.
267Providing and fixing of bathing accessories set of one pair of soap dish holder, one no. tumbler holder, one no. napkin ring, one no. 600mm glass shelf with all required fittings and accessories.
268Supply and installation of Stainless Steel Handwash Liquid Dispenser with all required fittings and accessories. Make: Jaguar/ Kohler/ Grohe/ Cera
269Providing and erecting water cooler having storage capacity 80Ltr. & cooling capacity 40 Ltr.per hour @ an ambient temp of 450C. The outlet temp. of the water should drop by 150 C within a hour, The water cooler should be comprising of hermetically sealed compressor, fan motor, condensing unit, water tank surrounded by evaporating coil, thermostats, relay etc. complete with necessary inlet & outlet connection. The body of water cooler will be made from Stainless Steel.
270Supplying & erecting 5 stage single reverse osmosis water purification system with M.S. powder coated frame, pre filter housing with "O" ring pre sediment filter GAC filter, carbon filter suitable buster DC pump capacity 80 psi, mention with 40 Osg inline type post carbon filter auto low & high pressure switches with following size of storage tank & LPH capacity & erected as directed with one year comprehensive maintenance guarantee. [B] 25 Ltr / Hr with 30 Ltr. S.S. Pressure Tank
271Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete.[A] 15 mm. Make: Astral, Supreme, Finolex, Prince
272Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [B] 20 mm. Make: Astral, Supreme, Finolex, Prince
273Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [C] 25 mm. Make: Astral, Supreme, Finolex, Prince
274Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [D] 32mm. Make: Astral, Supreme, Finolex, Prince
275Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [F] 50mm. Make: Astral, Supreme, Finolex, Prince
276Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete.65mm. Make: Astral, Supreme, Finolex, Prince
277Providing, fixing, jointing and testing, heavy quality cast steel / Brass ball valve single/doublepiece designed of approved make, including flanges / unions, nuts, bolts, washers, etc. complete, as per I.S 5212 approved by the Engineer-in-charge for water supply lines of the following nominal bore (NB) size: 25mm diameter. Make:ZOLOTO/VTC/SANT
278Providing, fixing, jointing and testing, heavy quality cast steel / Brass ball valve single/doublepiece designed of approved make, including flanges / unions, nuts, bolts, washers, etc. complete, as per I.S 5212 approved by the Engineer-in-charge for water supply lines of the following nominal bore (NB) size: 32mm diameter (Make:ZOLOTO/VTC/SANT)
279Providing and Fixing CPVC ball valve with all required accessories and connection. 25mm dia. Make: Astral, Prince, Finolex, Supreme
280Providing and Fixing CPVC ball valve with all required accessories and connection. 32mm dia. Make: Astral, Prince, Finolex, Supreme
281Providing, fixing, jointing and testing, heavy quality cast steel / Brass Non-return valve single/doublepiece designed of approved make, including flanges / unions, nuts, bolts, washers, etc. complete, as per I.S 5212 approved by the Engineer-in-charge for water supply lines of the following nominal bore (NB) size: 32mm diameter (Make:ZOLOTO/VTC/SANT)
282Providing erecting and fixing double coated SIntex or equivalent PVC. (ISI) water tank of required capacity each with all necessary fittings and connection etc. complete on terrace. (Make: Sintex / Kaka )
283Providing, laying and jointing in true line and level 40mm diameter U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line,pipe shall be jointed with each other with rubber lubricant, pipe shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. (Make: prince/ supreme / astral / finolex)
284Providing, laying and jointing in true line and level 50mm diameter U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line,pipe shall be jointed with each other with rubber lubricant, pipe shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. (Make: prince/ supreme / astral / finolex)
285Providing, laying and jointing in true line and level 75mm diameter U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line,pipe shall be jointed with each other with rubber lubricant, pipe shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. (Make: prince/ supreme / astral / finolex)
286Providing, laying and jointing in true line and level 110mm diameter U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line,pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diameter x 149 mm length x 145 mm height at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. (Make: prince/ supreme / astral / finolex)
287Providing, fixing and testing PVC Deep seal P-Trap of110 X 110 mm dia diameter, with necessary distance piece of 75mm dia pipe and 150 x 150mm heavy duty PVC three piece grating, making necessary holes and cutting in Slab/Walls, etc complete as per engineer in charge. (Make: prince/ supreme / astral / finolex)
288Providing, fixing and testing PVC Height Riser with wings of110 X 50 X 40 mm dia diameter, with necessary suported accessories, making necessary holes and cutting in Slab/Walls, etc complete as per engineer in charge. (Make: prince/ supreme / astral / finolex)
289Providing and supplying of Class SN8 Structured Wall polyethelene Piping systems (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application as per EN:13476-3 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the departmental stores etc. complete.(ID 150 mm diameter) Make: Astral, Supreme, Finolex, Prince
290Lowering, laying, fixing and jointing PVC/uPVC/cPVC pipes and specials of 160mm diameter including cost of conveyance from stores to site of works including cost of labour, material, cement solvent, giving satisfactory hydraulic testing as per ISI code. Make: Astral, Supreme, Finolex, Prince
291Excavation for foundation/utility services upto 1.5 m depth including sortingoutandstacking of useful materials anddisposing off the excavated stuff with all lead and lift.(E)HardRock
292Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each depositedlayer by ramming and watering. (Ramping by manual or mechanical means)
293Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Square mouth traps.(B) 150mm x 100mm size P or R type(make-Local )
294Providing and fixing, best Indian make 1st quality, salt glazed PVC Sewer (intercepting) trap, of 150 mm. x 150 mm. size with cleaning eye cap and metal stopper chain, set in CC 1:2:4 etc., complete in last manhole including vent / fresh air pipe.
295Construction of Manhole chambers 600mm X 600 mm and depth 1.0 m in brick or bela stone masonry, locally available in C. M. 1:6. Foundation concrete 150 mm thick in C. C. 1:4:8 of trap metal size 25 mm to 40 mm thick, inside cement plaster in C. M. 1:3 and cement pointing outside in C. M. 1:3 and top cover of precast RCC slab 100 mm thick (with key hole in two parts, each with handles or MS Bar etc. complete as given size) Upto 1 Mt. depth from G. L. to pipe invert level incl. complete civil works but excl. cost of excavation and refilling, with cast in situ RCC slab in one single piece with fixing of CI-MH Frame and cover (excl. cost of CI-MH Frame and cover) with 23 mm thick brick masonry wall in C.M.1:6. With precast slab in two parts 15mm.
296Providing & Fixing of factory made Precast Chamber, having size (in to in) of 800 mm (L) X 800 mm (B) X Height : 800 mm T-25 load carrying capacity - 10 T Axle Load - 5 T Wheel Load, confirming to IS requirements, having High Performance Self Compacting Concrete of M-40 cylinder strength/M-50 cube strength & use ofFe 500 D reinforcement. Excavation, back filling, preparing pcc foundation and all material transporation shall be on contractor"s scope.The precast Chamber unit should consist of special in built insert of suitable load carrying capacity at appropriate location for fixing De-shackle (Hanging hole) for safe & fast mechanical installation.Cut out holes hole should be providedfor utility connectionas per the requirement.The Precast cover having size 944 x 944 X 120 mm thick , designed forT-25 load carrying capacity - 10 T Axle Load - 5 T Wheel Load, confirming to IS requirements, having High Performance Self Compacting Concrete of M-40 cylinder strength/M-50 cube strength & use of Fe 500D reinforcement.The lid may have in build specially designed lifting inserts of appropriate load carrying capacity & fixed at specific location to avoid the tilting of the lid for safe & fast installation.In no case the casting shall be allowed to be prepared at site. It should be casted in the stringent atmospheric & pre-defined condition, as per approved QAP as by Engineer In charge,including making cut-outs, core cutting for ducts. Brand: Fuji Silvertech, and equivalent.Make: Fuji Silvertech or equivalent
297Providing & Fixing of factory made Precast Chamber, having size (in to in) of 1000 mm (L) X 1000 mm (B) X Height: 1000, mm T-25 load carrying capacity - 10 T Axle Load - 5 T Wheel Load, confirming to Japanese Industrial Standards (JIS) & meeting IS requirements, having High Performance Self Compacting Concrete of M-40 cylinder strength/M-50 cube strength & Fe 500 /Fe 500 D shall be used for reinforcement. Excavation, back filling, preparing pcc foundation and all material transporation shall be on contractor"s scope.The precast Chamber unit should consist of special in built insert of suitable load carrying capacity at appropriate location for fixing De-shackle (Hanging hole) for safe & fast mechanical installation.Hole should be provided at site (No Factory) for connection at the waffle side of chamber as per the site requirement.The Precast cover having size 1144 x 1144 X 150 mm thick, designed forT-25 load carrying capacity - 10 T Axle Load - 5 T Wheel Load, confirming to Japanese Industrial Standards (JIS) & meeting IS requirements, having High Performance Self Compacting Concrete of M-40 cylinder strength/M-50 cube strength & Fe 500 / 500D shall be used for reinforcement. Cover should have conical shape of 50 mm to 30 mm respectively for storm water intake. The lid may have in build specially designed lifting inserts of appropriate load carrying capacity & fixed at specific location to avoid the tilting of the lid for safe & fast installation.In no case the casting shall be allowed to be prepared at site. It should be casted in the stringent atmospheric & pre-defined condition, as per approved QAP as by Engineer In charge. Make: Fuji Silvertech or equivalent
298Providing laying (to level or slopes) and jointing reinforced concrete pipe Light duty non-pressure pipes I.S. class NP3 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(D) 300mm
299Providing, laying and jointing in true line and level 110 mm diameter U.P.V.C (Type A) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line,pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diameter x 149 mm length x 145 mm height at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. Make: Astral, Supreme, Finolex, Prince
300Providing, laying and jointing in true line and level 150 mm diameter U.P.V.C (Type A) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line,pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 150 mm diameter x 149 mm length x 145 mm height at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. Make: Astral, Supreme, Finolex, Prince
301Providing, Fixing, Installation and Testing of 100mm rainwater outlets 2HP-2W/3HP-2W/ 4HP-2W* are to be ACO Building Drainage HP Two-Way screw outlets with locked flat grating supplied by ACO Building DrainageSG17 5TE. All components to be manufactured from grade LM6 aluminium alloy to BS 1490/ gun-metal to BS EN 1982. complete as per site engineer in charge. Make: Astral, Supreme, Finolex, Prince
302Providing, Fixing, Installation and Testing of 150mm rainwater outlets 2HP-2W/3HP-2W/ 4HP-2W* are to be ACO Building Drainage HP Two-Way screw outlets with locked flat grating supplied by ACO Building DrainageSG17 5TE. All components to be manufactured from grade LM6 aluminium alloy to BS 1490/ gun-metal to BS EN 1982. complete as per site engineer in charge. Make: Astral, Supreme, Finolex, Prince
303Providing and fixing, PVC cowl, 110mm diameter on PVC ventilating pipes and verticalsfor soil and waste Pipes at top level / terrace level, as specified and required, etc. complete. Make: Astral, Supreme, Finolex, Prince
304Providing and fixing, PVC cowl, 150mm diameter on PVC ventilating pipes and verticalsfor soil and waste Pipes at top level / terrace level, as specified and required, etc. complete. Make: Astral, Supreme, Finolex, Prince
305Providing & fixing of factory made FUJI SIlvertech Precast(DUSD)U shape surface storm water drain having size of 450 mm width x 450 mm heightinto in dimenson from top, having units of2000 mm long, T-25 load carrying capacity - 10 T Axle Load - 5 T Wheel Load confirming to JIS having high performance self-compacting concrete of M40 Cylinder Strength/ M50 Cube Strength & Fe 500 / Fe500D shall be use for reinforcement. Excavation, back filling, preparing pcc foundation and all material transporation shall be on contractor"s scope. The product shall have tie shape joint 10-20 mm width X 25 mm depth groove as per JIS on both sides of each Storm water drain for jointing two precast drains using cement mortar or suitable non shrink grout.The precast Storm water drain must consist ofspecial in built inlets at appropriate location for fixing De-shackle for mechanical installation , including supply ,transportation ,installation on specific location at site in line ,level , gradient and plumb with necessary testing commissioning etc complete as per instruction of engineer in charge. In no case the casting shall be allowed to be prepared at site. It should be casted in the stringent atmospheric & pre-defined condition, as per approved QAP as by Engineer incharge.
306Providing & fixing of Factory made FUJI Silvertech Precast Lidhaving length of 500 mm, width suitable for placing on U - Shape Drain (DUSD) sizes 450 x 450 thickness of 130 mm. Lid should have T-25 load carrying capacity – 10 T Axle Load – 5 T Wheel Load, confirming to JIS & meeting IS requirements having High Performance Self Compacting Concrete of M-40 cylinder strength/ M-50 cube strength. Excavation, back filling, preparing pcc foundation and all material transporation shall be on contractor"s scope. The Fe 500/ Fe500D shall be used for reinforcement. Lid should have antiskid finish at Top.The each lid unit should have slits of 155 mm X 20 mm slit on two sides along the width of the lid for storm water intake. In no case the casting shall be allowed to be prepared at site. It should be casted in the stringent atmospheric & pre-defined condition, as per approved QAP as by Engineer Incharge.
307Providing laying (to level or slopes) and jointing reinforced concrete pipe Light duty non-pressure pipes I.S. class NP3 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(D) 500mm
308Preparing structural design of RCC Under Ground / Partially under ground /above high ground level Reservoir and constructing of required capacityas per relevant I.S. standards in M30 concrete gradewith HYSD Fe 500D reinforcement and constructing the same, including excavation in all types of soil strata (including rock) including shoring strutting if required, for loose soil / to protect from collapse, casting 100 mm thick P.C.C. levelling course in M-15, Refilling the pit with proper soil and disposing of the surplus stuff at all lead. Including cement plaster in CM 1:2 with approved water proofing compound to all over inside container (i.e. walls, base, top slab/dome bottom etc. all). Including Soil testing. Including all types of labour and material charges of lowering, laying, erecting / hosting and jointing of pipe assembly to inlet, outlet overflow, washout and bye pass arrangement as per hydraulic design. Providing and fixing accessories, CI Manhole frame and cover, water level indicator, adequate cowl type ventilators or lantern type ventilator with stainless steel jail. RCC chambers for valves. Providing and applying three coats of cement paint / snowcem to the out side face of structure. It also includes satisfactory water tightness test as per relevant I.S. code and painting name of scheme and capacity on the tank as per direction of engineer in charge.
309Supply, fixing and jointing of heavy class GI puddle flange pipes epoxy coated, 50 mm dia and minimum 400 mm long clear ends outside the RCC surface, and fixed in underground sumps, water tanks etc. complete, with end joints either screwed / flangedas required with endcaps / plugs complete as per the requirement of E-i-C (Local Make)
310Supply, fixing and jointing of heavy class GI puddle flange pipes epoxy coated, 80 mm dia and minimum 400 mm long clear ends outside the RCC surface, and fixed in underground sumps, water tanks etc. complete, with end joints either screwed / flangedas required with endcaps / plugs complete as per the requirement of E-i-C (Local Make)
311Supply, fixing and jointing of heavy class GI puddle flange pipes epoxy coated, 100 mm dia and minimum 400 mm long clear ends outside the RCC surface, and fixed in underground sumps, water tanks etc. complete, with end joints either screwed / flangedas required with endcaps / plugs complete as per the requirement of E-i-C (Local Make)
312Supply, fixing and jointing of heavy class GI puddle flange pipes epoxy coated, 150 mm dia and minimum 400 mm long clear ends outside the RCC surface, and fixed in underground sumps, water tanks etc. complete, with end joints either screwed / flangedas required with endcaps / plugs complete as per the requirement of E-i-C (Local Make)
313Providing and fixing electronic type level indicator for water tanks mounting in panel with level display, alarm (level low or high), and manual reset for alarm, potential free set point contacts etc. complete with electrical wiring to probes and all accessories complete the work. Provision to connect to the building Automation system or pump controllerthrough a suitable port.(Make: Wilo)
314Horizontal multistage, Centrifugal clear water pumps with SS-304 Casing, S.S 304 Impeller, SS-304 Shaft, SS-304 Base and Head TEFC motor based CI with CED coated (with Mechanical seal) Vendor to submit performance curves and technical catalogue of the proposed model for review and information. (Company Fitted System & System Test Certificate require for the same). Electrical Starter panels complete with O/L Relay with Single phasing preventer feature, earth leakage relay, ON-OFF and Trip Indicating lamps, interlocking, cascade operation, working / standby selection, etc. suitablefor the motor H.P. as specified below and with provision for manual auto on/off selector switch complete as required. Pre-charged diaphragm pressure vessel with MS connection, connected to outlet header with necessary connection, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be 100 litters (approx.) or as per manufacturer recommendation). Set of accessories such as M.S. Zinc Coated headers for suction and discharge, control valves, non return valves,Foot valve with Strainer, pressure switches, pressure gauge, inter connecting power and control cabling etc. complete.. As per complete company Fitted and tested system Capacity per pump-1.66 LPS [6 m3/hour],System Flow - 3.32.78LPS [12 m3/hour],Head:-40-45 mtr. 2 Nos. Pumps (1 Working + 1standby) Make: Wilo, Kirloskar, Grundfos
315Supply of Submersible single stage single entry pumps connected to submersible motor (The motor shall be watertight according to IEC class IP 68, and incorporate class F insulation materials to withstand a continuous operating temperature of 155 deg C) for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with Double mechanical seal, pump connector unit with rubber diaphragm and bend, electrical panel with in built level controller with operational mode as one pump working at low level, both pumps at high level with a hooter alarm and cut off at dry level as determined. The pump shall be provided with a lifting devise of pull chain or guide rail. (Pumps shall be installed in a set of two pumps One working and One standby, with cascade operation).Pumps suitable to handle solids upto 40 mm size with C.I. body, SS304 impeller & SS shaft with 10 mtrs cable, double mechanical seal.Electrical Starter panels complete with Over load & Under Current Relay with Single phasing preventer feature,ON-OFF and Trip Indicating lamps, contactors contacts for BMS System, interlocking, level controller with operational mode as one pump working at low level, both pumps at high level with a hooter alarm and cut off at dry level, cascade operation, working / standby slelction, etc.including with discharge valve and NRV, suitablefor the motor H.P. as specified below. As per complete company Fitted and tested system Capacity per pump-1.39 LPS [5 m3/hour],System Flow - 2.78LPS [10 m3/hour],Head:-18-20 mtr. 2 Nos. Pumps (1 Working + 1standby). Make: Wilo, Kirloskar, Grundfos
316Supply, installation, testing & commissioning of Submersible Open well single stage single entry pumps with C.I Casing, C.I Impeller and SS Body SS-304 Shaft,connected to TEFC submersible motor for 415 + 10% volts, 1 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, electrical panel with in built level controller with operational mode as pump working at low level, as well pump at high level with a hooter alarm and cut off at dry level as determined. The pump shall be provided with a lifting devise of pull chain/guide rail & G.I. heavy class rising main of 1.0 m length including interconnecting piping, valves (Ball Valve / Butterfly), Non return valves (GM/CI) 15 m cable etc. as per requirement complete in all respects. (Pumps shall be installed in a set of One pump operation).Electrical Starter panels complete with O/L Relay with Single phasing preventer feature, earth leakage relay, ON-OFF and Trip Indicating lamps, contactors contacts for Building Automation System, interlocking, level controller with operational mode as one pump working at low level, both pumps at high level with a hooter alarm and cut off at dry level, cascade operation, working / standby slelction, etc. suitablefor the motor H.P. as specified below and with provision for remote P.B. on/off complete as required. The on/off operations for all pumps shall be available on central BMS system Capacity per pump-1.11 LPS [4 m3/hour],System Flow - 2.22LPS [8 m3/hour],Head:-25-30 mtr. 2 Nos. Pumps (1 Working + 1standby). Make: Wilo, Kirloskar, Grundfos
317Supply, installation, testing and commissioning of percolation well including all work like drilling, compressor work, gravel packing, mud slurry disposal, clay packing and including of all materials like 300mm UPVC pipe, 300mm wire screens, 300mm collar joint, accessories, gravels, sand, sand filteration module etc. Site cleaning, mud pit, mud refilling for borewell must be in the contractor"s scope. Contractor has to maintain the percolation well upto three years after installation.
318Providing & Fixing of(Monoblock/Openwell submersible) pumpset of having discharge 2 lps@15 mtrhead .suitable for pumpset having panel boxand fixed alongwith following accessories starter ,start / stop push buttons , Ammeter,Voltmeter , Indicating lamps, MCB ,with cable, etc.
319Providing and fixing ofcontrol panelsuitable for pumpset having panel boxand fixed alongwith following accessories starter ,start / stop push buttons , Ammeter,Voltmeter , Indicating lamps, MCB ,with cable, etc.
320Providing & Fixing of,Suction ,Delivery & Header Pipe
321Providing & fixing of controlValve /Butterfly Valvein mainlinefor bypass and flow diversion of approved quality 2"
322Providing & fixing of Non Return Valveto prevent back flow 2"
323Providing, laying & jointing in position PVC/ HDPE pipe conforming to ISI standard and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers" instruction, PVC pipe 110mm-10 kg/cm2
324PVC pipe 90mm-10 kg/cm2
325Earthworkexcavationand refilling 300x450mm
326Supply and fixing of Direct burial 16 AWG x 1C cablefor TWO way communication betweencontroler and valves
327PVC conduit Pipe complete32 mm
328Supply and fixing of PHC-601i-E 6-station 230 VAC European indoor plastic controller with Wi-Fi connection internal transformer control system , cycle +soak, Raindelay, SOLARSYNC Mini weather station,controlling upto 1 mastervalve with diagnostic feature in wire shorttest ,voltage test at stations, standard accessories complete
329Supplyand fixing of Voltage stabilizer
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail