| 1 | Supply, installation testing commissioning of 10 Sqmm 3 core XLPE insulated armoured cable, PVC tape inner sheathed for multiple cores, ISI marked and conforming to IS 7098 part-1, Make:- RR or equivalent in Finolex, Havells. |
| 2 | Supply, Errection,Testing & Commissioning ofLED 4ft Batten with a nominal system lumen output of 2200 lumens and a minimum system efficacy of 115 lm/W. The luminaire shall have a rated system lifetime of 35,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD < 20% and PF > 0.9. The luminaire housing should be made of Extruded Aluminium with a PC glossy diffuser. The total power consumption should not exceed 21W (including driver). Driver efficiency should be >95%. BIS certification is required for LED Driver & Luminaire.Similar to Philips Make Smart brite BATTEN BN021C LED 22S 6500 PSU GR, or equivalent in Havells, Crompton (Free 5 Years warranty ) |
| 3 | Supply, Errection,Testing & Commissioning ofthe LED based Flood light, housing made up of pressure die cast aluminum with effective thermal management, sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of 100 lumen/Wattand a minimum system lumen output of 9500 lumens and maximum system wattage of 105 Watts.The fixture shall have a CRI of minimum 70;Color temperature should be of 5700K. The fixture shall be designed for a system life of 30,000 hours @L70B50. Ingress Protection of IP65 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK07.The fixture driver should have an operating voltage range of 120-270 V, surge protection of >=4KV, PF >0.9 and THD<10%.Driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have in house lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Luminaire and Driver should be of same make and BIS approved. Similar to Philips CAT No. -BVP182 LED100 CW FG WB 100W 120-270 PSU or equivalent in Havells, Crompton (Free 5 Years warranty ) |
| 4 | Supply, Errection,Testing & Commissioning ofthe LED Recessed Down lighter with a nominal system lumen output of 2700 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.9. The luminaire housing should made of pressure die cast aluminium and fully diffused cover . The total power consumption should not exceed 24W (including driver).Driver efficiency should be >95%. BIS certification is required for LED Driver & Luminaire. Similar to Philips Make GREENPERFORM DN395 LED27S 6500 PSU WH or equivalent in Havells, Crompton (Free 5 Years warranty ) |
| 5 | Supply, Errection,Testing & Commissioning oftheLED Recessed Down lighter with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.9. The luminaire housing should made of pressure die cast aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The total power consumption should not exceed 18W (including driver).Driver efficiency should be >95%. BIS certification is required for LED Driver & Luminaire. Similar to Philips Make GREENPERFORM DN296B LED20S-6500 PSU WH, or equivalent in Havells, Crompton. (Free 5 Years warranty ) |
| 6 | Supply, Errection,Testing & Commissioning ofthe LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and anoutstanding backlit solution efficacy of atleast 120 lumen/watt and maximum system wattage of 30W. The luminaire should have outstanding backlit solution efficacy. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10%. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Similar to Philips RC 370 LED 36S 6500 PSU WH, or equivalent in Havells, Crompton. (Free 5 Years warranty ) |
| 7 | Supply, Errection,Testing & Commissioning ofthe LED indoor surface down lighter suitable for general lighting. Luminaire should have polycarbonate cover withdiffused optics. The luminaire should have CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification. The fixture should have a minimum system efficacy of 100 lumen/Wattand a minimum system lumen output of 1200 lumens and maximum system wattage of 12 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 30k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 , THD <10%. he fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have in house lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Similar to PHILIPS Sleek Surface SM250C LED12S- 6500 PSU WHor equivalent in Havells, Crompton.(Free 5 Years warranty ) |
| 8 | Supply, Errection,Testing & Commissioning oftheRecess LED 595x595mm fitting made of CRCA with fully covered by Polystyrene diffuser, LED Used shall be SMD type and fixture should have minimum system lumen of 4200lm &minimum efficacy at System level >=120lumens/watt, Max power consumption 36W.Life of fixture : 50K Hrs. @ L70B50 Lumen maintenance, CCT of 4000/6500K (SDCM<5), CRI >80, ripple<5%& THD<10%. An operating Voltage Range of 140 - 270 V. Minimum Internal Surge Protection 4KV. It should have min IP-20 protection. The fixture design should comply with IS:10322 & Must beEMC / EMI compliance maintaining driver leakage current as per as per IEC 60598. Driver efficiency should be >95%. BIS certification is required for LED Driver & Luminaire, Luminaire manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer. Similar to Philips RC380B G6 LED42S-6500 G6 L60W60 PSU OD or equivalent in Havells, Crompton.(Free 5 Years warranty ) |
| 9 | Supply, Errection,Testing & Commissioning ofthe LED 2ft Batten with a nominal system lumen output of 1150 lumens and a minimum system efficacy of 115 lm/W. The luminaire shall have a rated system lifetime of 35,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD < 20% and PF > 0.9. The luminaire housing should made of Extruded Aluminium with a PC glossy diffuser. The total power consumption should not exceed 10W (including driver). Driver efficiency should be >95%. BIS certification is required for LED Driver & Luminaire. Similar to Philips Make Smart brite BATTEN BN021C LED 12S 6500 PSU GR or equivalent in Havells, Crompton.(Free 5 Years warranty ) |
| 10 | Supply, Errection,Testing & Commissioning ofthe Recess/ Surface Highway Luminaire made of Aluminum Die-casting (RAL9003), Cover build in Tempered glass of high transmittance, maximum wattage of 80 watt, minimum lumen output -10000 lumens, IP65 / IK08, CRI = 70, Class I,Burning Hours 50,000hrs@Ta45°C,Lumen Efficacy - 125 lm/W,5700K, 50 Hz,Lifetime 50Khrs @L70B50 ;IP65; IK08,Operating voltage of 140-270V with cut off and auto restart feature @320V, THD<10% .Similar to Philips Make BY286V LED100S CW M3-S60 PSU FG WH V2 or equivalent in Havells, Crompton.(Free 5 Years warranty ) |
| 11 | Supply, Errection,Testing & Commissioning ofthe Recess LED Down lighter made of pressure die cast alu. housing, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=110lumens/watt with Minimum system Lumens 600 with maximum system wattage of 5.5W Life of fixture (Including Driver) : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K (SDCM<5), CRI >80, PF >0.95, Min working temp range - 0°C < Ta < 45°C,an operating Voltage Range of 130 - 320 VAC. Minimum Internal Surge Protection 2.5KV & , The fixture design should comply with EMC / EMI compliance along with BIS certification for LED Driver & Luminaire. Luminaire manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer. Similar to Philips DN295B LED6S-6500 PSU WH or equivalent in Havells, Crompton.(Free 5 Years warranty ) |
| 12 | Supply, Errection,Testing & Commissioning ofthe LED based Flood light, housing made up of Pressure Die Cast Housing LM 6 Alloy/ Anti Dust Exposed Lens, sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of greater than 110 lumen/Wattand a minimum system lumen output of 8400 lumens and maximum system wattage of 70 Watts.The fixture shall have a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=08.The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=4KV, PF >0.9 , and SDCM<5. The driver should be BIS approved, fully potted and encapsulated with 440V Stress Voltage protection for 8 Hrs. High Cut off : 325V(+/- 15V) and Auto Restart function should also be available within the fixture. The fixture should comply with the parameters as per IS10322. The LED connecting clips made out of 2.64 mm dia x 230 mm long GI wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/ partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 mm x 25 mm at 230 mm c/c, including jointing and finishing to a flus |