Repair Replacement Of Sewar Lines Including Cleaning Of Manholes Septic Tank Rcc Cover Slab And Sanitary Fittings Under Age Br I Chandipur , chandipur-Odisha

Military Engineer Services-MES has published Repair Replacement Of Sewar Lines Including Cleaning Of Manholes Septic Tank Rcc Cover Slab And Sanitary Fittings Under Age Br I Chandipur . Submission Date for this Tender is 27-08-2022. Manhole Construction Tenders in chandipur Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

33432443
Repair Replacement Of Sewar Lines Including Cleaning Of Manholes Septic Tank Rcc Cover Slab And Sanitary Fittings Under Age Br I Chandipur
Open Tender
Indian
Odisha
chandipur
27-08-2022

Tender Details

Repair Replacement Of Sewar Lines Including Cleaning Of Manholes Septic Tank Rcc Cover Slab And Sanitary Fittings Under Age Br I Chandipur

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: REPAIR / REPLACEMENT OF SEWAR LINES INCLUDING CLEANING OF MANHOLES, SEPTIC TANK, RCC COVER SLAB AND SANITARY FITTINGS UNDER AGE B/R-I CHANDIPUR
Sl. No. Item Description
1NOTE (Applicable for all items) :- The bidders/contractorsare advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.
2M & L for cleaning of blocked/chocked CI / PVC (SWR) pipe line of 100 mm dia from WC to gully trap, manhole or from cleaning eyes in any depth by mechanical means and well flushing the complete line including removing of sludge /waste to low lying areas within 200 m distance and buring the same properly to the entire satisfaction of Engineer-in-Charge with and including taking out and re-fixing of manhole covers duly set in cement mortar 1 : 4 as wherever required complete all as specified and directed.
3M & L for cleaning of blocked/chocked CI / PVC (SWR) / SWG, AC or RCC pipe line of 150 mm dia from WC to gully trap, manhole or from cleaning eyes in any depth by mechanical means and well flushing the complete line including removing of sludge /waste to low lying areas within 200m distance and buring the same properly to the entire satisfaction of Engineer-in-Charge with and including taking out and re-fixing of manhole covers duly set in cement mortar 1 : 4 as wherever required complete all as specified and directed.
4M & L for cleaning of blocked/chocked CI / PVC (SWR) / SWG, AC or RCC pipe line of 150 mm dia sewage line (exc 1.5 m and n.exc 3.00 m in depth from top of manholes to bottom of pipe line) by mechanical means and well flushing the complete line including removing of sludge /waste to low lying areas within 200m distance and buring the same properly to the entire satisfaction of Engineer-in-Charge with and including taking out and re-fixing of manhole covers duly set in cement mortar 1 : 4 as wherever required complete all as specified and directed.
5M & L for cleaning of blocked/chocked CI / PVC (SWR) / SWG, AC or RCC pipe line of 200 mm dia sewage line (exc 1.5 m and n.exc 3.00 m in depth from top of manholes to bottom of pipe line) by mechanical means and well flushing the complete line including removing of sludge /waste to low lying areas within 200m distance and buring the same properly to the entire satisfaction of Engineer-in-Charge with and including taking out and re-fixing of manhole covers duly set in cement mortar 1 : 4 as wherever required complete all as specified and directed.
6M & L for cleaning of blocked/chocked CI / SWG, AC or RCC pipe line of 200 mm dia sewage line(exc.3 m and n.exc 4.5 m in depth from top of man holes to bottom of pipe line) by mechanical means and well flushing the complete line including removing of sludge /waste to low lying areas within 200m distance and buring the same properly to the entire satisfaction of Engineer-in-Charge with and including taking out and re-fixing of manhole covers duly set in cement mortar 1 : 4 as wherever required complete all as specified and directed.
7M & L for cleaning of blocked WC incl cleaning line from WC trap upto first manhole by mechanically means complete all as specified and directed.
8M & L for cleaning of blocked nahani trap of bathroom, kitchen & WHB including cleaning of pipe line upto gully trap as required by mechanically means complete all as specified and directed.
9M & L for cleaning of blocked gully trap by mechanically means complete all as specified and directed.
10Taking off existing covers of septic tank, cesspool, soak well, lift well, soak pit or manholes and cleaning the same of any size/capacity by dewatering and taking out sludge in liquid mud, silt or in solid state after emptying the water with the help of combined high pressure water jetting cum suction (Vacuum) type machine mounted on vehicle having facilities of high pressure of water thermoplastic fiber blended water jetting hose & through conical or round shape nozzle pipe and removing the sludge to a distance not exceeding 1500m and burying the sludge in newly excavated pits of suitable sizes and covering the same with excavated earth and placing back in position the removed covers and set in cement mortar 1 : 4 complete all as specified and directed. (Note : Use bleaching powder for disinfection purposes in all stages of cleaning, no separate payment will be made for this)
11Excavating in trenches n.exc 1.50 m wide & n.exc 1.50 m in depth for foundation etc or for manholes, cesspits, shafts etc not exc 10 Sqm on plan and getting out in soft / loose soil, complete all as specified and directed.
12Excavating in trenches n.exc 1.50 m wide & exc 1.50 m but n.exc 3 m in depth for foundation etc or for manholes, cesspits, shafts etc not exc 10 Sqm on plan and getting out in soft / loose soil, complete all as specified and directed.
13Excavating in trenches n.exc 1.50 m wide & exc 3 m but n.exc 4.50m in depth for foundation etc or for manholes, cesspits, shafts etc not exc 10 Sqm on plan and getting out in soft / loose soil, complete all as specified and directed.
14Dismantling of reinforced concrete drain pipes 150 mm dia, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
15Dismantling of reinforced concrete drain pipes 200 mm dia, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
16Dismantling of reinforced concrete drain pipes 300 mm dia, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
17S & F reinforced concrete pipes 150 mm dia, class NP 2 with one collar per length of pipe complete all as specified and directed.
18M & L for concrete bed to drain pipe in Cement Concrete (1:3:6) type C2 using40 mm stone aggregrateincluding packing under, and haunching against the sides of pipe after they are laid and tested of 150 mm bore, complete all asspecified and directed by Enginner-in-Charge.
19S & F reinforced concrete pipes 200 mm dia, class NP 2 with one collar per length of pipe complete all as specified and directed.
20M & L for concrete bed to drain pipe in Cement Concrete (1:3:6) type C2 using40 mm stone aggregrateincluding packing under, and haunching against the sides of pipe after they are laid and tested of 200 mm bore, complete all asspecified and directed by Enginner-in-Charge.
21S & F reinforced concrete pipes 300 mm dia, class NP 2 with one collar per length of pipe complete all as specified and directed.
22M & L for concrete bed to drain pipe in Cement Concrete (1:3:6) type C2 using40 mm stone aggregrateincluding packing under, and haunching against the sides of pipe after they are laid and tested of 300 mm bore, complete all asspecified and directed by Enginner-in-Charge.
23Taking out / demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) of dia 150 mm dia set in cement mortar complete all asspecified and directed by Engineer-in-Charge.
24M & L SWG drain pipe 150 mm internal dia, grade `A" laid in trenches & jointed in cement mortar 1:1complete all asspecified and directed by Enginner-in-Charge.
25M & L PCC 1:4:8, type D-2 (using40 mm graded crushed stone aggregrate)as in bed of drain pipes including packing under and haunching against sides of pipes after they are laid and tested for 150 mm dia, complete all asspecified and directed by Enginner-in-Charge.
26Taking out / demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) of dia 200 mm dia set in cement mortar complete all asspecified and directed by Enginner-in-Charge.
27M & L SWG drain pipe 200 mm internal dia, grade `A" laid in trenches & jointed in cement mortar 1:1complete all asspecified and directed by Enginner-in-Charge.
28M & L PCC 1:4:8, type D-2 (using40 mm graded crushed stone aggregrate)as in bed of drain pipes including packing under and haunching against sides of pipes after they are laid and tested for 200 mm dia, complete all asspecified and directed by Enginner-in-Charge.
29Demolition of cement concrete of any descreption and in any position not otherwise specifically provided for complete all asspecified and directed by Enginner-in-Charge.
30Demolition of Brick work built in cement mortar complete all as specified & directed.
31M & L for Brick work with flyash bricks old size, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 etc complete all as specified & directed.
32M & L for brick work with Sub class ‘B’ Bricks (except bricks) straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed.
33M & L Brick work with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified & directed.
34M & L PCC 1:4 :8 type D2 (using 40mm graded stone aggregate) as in foundation of manholes etc complete all as specified and directed
35M & L PCC 1:2 :4 type B-0 (using 12.5 mm graded stone aggregate) as in benching, coping complete all as specified and directed.
36M & L PCC 1:2 :4 type B-2 (using 40 mm graded stone aggregate) as in surface channels and drains complete all as specified and directed.
37Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed .
38M & L for 15mm thick rendering in cement mortar 1:4 on brick or concrete surfaces of wall finished even & smooth complete all as specified and directed.
39M & L precast RCC 1:2 :4type B-1 (using 20mm graded stone aggregate) in manhole covers incl necessary form work and set in CM 1:4 complete all as specified and directed.
40M & L Mild steel TMT steel reinforcement bars (Fe500 D) 10 mm dia and over cut to length, bent to shape required incl cranking, hooking ends and binding with and including MS wire(annealed) not less than 0.9mm dia complete all as specified and directed.
41All as per Sl Item 39 above but 6 to 8 mm dia.
42S & F of MS framed work such as grills, gratings etc with ends of bars shouldered and or riveted or forged into spikes, framed guard bar, barred iron door, ladders, framed balusters, walk way, railings frame work of water tank and similar work confirming to Fe 290 Gde E165 complete all as specified and directed.
43Returning filling in trenches incl spreading, leveling, watering & well ramming in layers not exc 25 cm thick complete all as specified and directed.
44Removing excavated materials n.exc 50m & depositing where directed at a level n.exc 1.5m above from starting point complete all as specified and directed.
45S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors 75 mm diacomplete all as specified and directed.
46S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls 75 mm diacomplete all as specified and directed.
47S & F PVC (SWR) bends 75 mm diacomplete all as specified and directed.
48S & F PVC (SWR) junction single, 75 mm dia (Single T) equal or unequal complete all as specified and directed.
49S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors 110 mm diacomplete all as specified and directed.
50S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls 110 mm diacomplete all as specified and directed.
51S & F PVC (SWR) bends 110mm diacomplete all as specified and directed.
52S & F PVC (SWR) junction single, 110 mm dia (Single T) equal or unequal complete all as specified and directed.
53S & F PVC (SWR) branch piece, single (single Y) equal or unequal 110 mm diacomplete all as specified and directed.
54M & L for PVC (SWR) floor trap, diameter of outlet in 75 mm, plain with grating including jointing with solvent cementcomplete all as specified and directed.
55M & L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
56S & F in repairs Vitreous china wash down water closet pan (pedestal pattern) including "P" or "S" Trap with necessary, fixing arrengement including plastic water closet seat cover white with recessed bottom and cover fixed with aluminium hinging device complete all as specified and directed.
57S & F Vitreous china Squatting panOrissa pattern of size 580 mm x 440 mm wite with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding in repairs complete all as specified & directed.
58M & L for PVC valve less syphonic action type flushing cistern 10 ltr capacitylow levelwhite with inlet ball valve, floatflush pipe and handle including bracket fixed.
59Taking up or down steel tubing 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
60S & F GI pipe medium grade 15 mm dia bore galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
61S&F vitreous China bowl urinal flat back size 465 x 365 x 265mm white (minimum) withgrating and union for discharge pipe (excluding flushing cistern, flush pipecomplete including waste coupling & waste pipe and providing & fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement fixed in repairs complete all as specified and directed.
62Supply only Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
63Cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in PCC 1:2:4 type B1 smooth finished & reforming benching as required for 150mm dia pipe complete all as specified and directed.
64All as per Sl Item No. 62 above but for 200 mm dia pipe complete.
65Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises.
66M & L for 15 mm thick screed bed or bedding layer of mortar in CM 1:6 for laying floor finishes complete all as specified and directed.
67M & L for10 mm thick rendering in CM 1:4 on brick or concrete surfaces as in backing coat to receive tile finish as in skirting and dados complete.
68M & L joint free glazed ceramic coloured tiles as in vertical surfaces 450 mm x 300 mm x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles.
69M & L for Non Skid coloured ceramic joint free tiles 7 to 8 mm thick areaof each tile exceeding 0.06 sqm but not exc 0.11 sqm ( 300 x 300 mm ) in floors etc set & jointed in neat cement slurry and pointed in coloured cement complete all as specified and directed.
70M & L for on site LLDPE septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation,vent shaft ,connection etc complete for 10 user complete all as per manufacturer"s instruction. (Make Sintex / Supreme or equivalent)
Disclaimer :