Supply Of Cardiothorasic Implants Ctvs Vascular Products 1 Lohexol For Vascular Procedures 35O X So Ml In Plastic Polypropylene Bottle. 2 Lohexol For Vascular Procedures 350 X 10O Ml In Plastic Polypropylene Bottle. 3 Lohexol For Vascular Procedures 350 X 200 Ml In Plastic Polypropylene Bottle. 4 Lohexol For Vascular Procedures 350 X 5Oo Ml In Plastic Polypropylene Bottle. 5 Lodixanol Vascular Procedure 320 X 1O0 Ml In Plastic Polypropylene Bottle. . Syringe For Pressure Injector Compatible With Imaxon Injector Zy6322 -.— - Syringe For Pressure Injector Compatible With Imaxon Injector Art-7O0 — - V Adoptor For Pressure Injector Compatible With Lmaxon Injector 6 — 8 9 Pnumbra Catheter For Thrombosuction Compatible To Pnumbra Machine Cat6 10 Pnumbra Catheter For Thrombosuction Clotting Compatible To Pnumbra Machine Cat8 Seprator For Thrombosuctiorn Clottin8 Compatible To Cat 6 Catheter And Pnumbra Machine 11 12 Seprator For Thrombosuction Clotting Compatible To Cat 8 Catheter And Pnumbra Machine - 13 Canister For Thrombosuction Coting Exudate Compatible To Pnumbra Machine 1000 Ml 14 Tubing For Thrombosuction Clotting Compatible To Pnumbra Machine 15 Pur Catheter 166 Leflgth 15 And 2O Cm With Guide Wire 0.9X4oomm Introducing Needle Drug Delivery System 16 2.45% Activated Glutaraldehyde With A Powder Activator, 510K Cleared And Effective Against Human Corona Virus. It Should Be Endorsed By Minimum Five Mdms: Karl Storz, Pentax, Stryker, Richard Wolf, Philips For Their - Rigid & Flexible Telescopes, Fiber Optic Cables, Tee Probes . Should Have Disinfectant Manufacturer Compatible Tray Made Of Glass Filled Polypropylene Which Can Be Steam Sterilized. Should Also Have Test Strip Which Consists Of Sodium Sulfite And Dyes Impregnated And Dried On Filter Paper. Pack Size= 5 Litre Jar 17 Solution Containing Benzotriazole, Nh ( Hydroxyethyl ) -Ethylenediaminetriacetic Acid ( He Dta ) , Dipotassiu M Hydrogen Phosphate, Potassium Dihydrogen Phosphate And 0.55% W / V Opa.. 51Ok Cleared And Effective Against Human 18 Corona Virus And Cytomegalo Virus. It Should Be Endorned By Minimun Five Mdm’S: Karl Storz, Pentax. Stryker. Richard Wolf, Olympus For Their - Rigid & Flexible Telescopes, Fiber Optic Cables, . Also Should Be Endorsed By Aer Manufacturers.Should Also Have Test Strip Which Consists Of Sodium Sulfite And Dyes Impregnated And Dried On Filter Paper. Pack Slze 5 Litre 19 Effervescent 50% Troxlosene Sodium Tablet Sg Each Tablet. Pack Size : 5O Tab / Bt. 20 Trays Trays Made Of Glass Filled Polypropylene Which Can Be Steam Stenlize And Ce Approved Ror Disinfection, 21 Dacron Grafty 6X12 22 Dacron Grafty 7X14 23 Dacrongraftst 6X20 24 Dacron Graft St 6X40 25 Dacron Graftst 6X70 26 Dacrongraftst 7X20 27 Dacron Graft St 7X4o : 28 Dacron Graft 5T 7X70 29 Dacron Graft St 8X40 _____________________..._____.____________ 30 Ptfe Graft 6X20 _._______.- ____ __________________._____ 31 Ptfe Graft 6X6s ____ ______..__ 32 Ptfe Graft 6X75 ___-.______________ 33 Ptfe Graft 4X4o 34 Ptfe Graft 5X2o _______ .._____ 3S Ptfe Graft 7X4o _______.________ 36 Ptfe Graft 8X4o ______ _________________________________.___________ 37 1Abp Balloon Compatible To Maquet Machhe. 38 Cardiacstablizermlcs 39 Platipus 40 Picco Carheter Continlous Cardiac Output Monuter Catheter With Injector Housing 3 Fr X 7 Cm — 41 Picco Catheter Continious Cardiac Output Monfter Catheter With Injector Housing 4 Fr X 8 Cm Picco Catheter Contiriious Cardiac Output Moniter Catheter With Injector Housing 5 Fr X 20 Cm ____ Embolactomy Catheter 44 Ptfe Felt 45 Femoral Arterial Canula 46 Venous Arterial Canula 47 Ptfe Bifergated Graft 48 Lineaar Cuttur Stapler 6O Mm. Unlversal Instrument 2 Rows On Both Cut Line Side With B Form Staple Technology Linear Cutter Reload For Medium Tissue, No Of Staples 84, Open Staple Height 3.8Mm, Formed Closed Stapple Height 1.5Mm Blue, Cut Line 6Cmhnm, Staple Line 63 Mm , Compatlbe With Linear Cutter Reload For Thick Tissue, Staples 84, Open Staple Height 4.8Mm, Formed Closed Stapple Height 2.0Mm O Green, Cut Line 60Mm, Staple Line 63 Mm, Compatible With Linear Cutter 60Mm Universal Instrument 2 Rows On _____ Both Cut Line Side With B Form Staple Technology 51 Disposable Curved Cutter Stapler , Open Leg Length 40Mm, Formed Closed Staple Height 2.0 Mm Blue Or Green 52 Siagle Use Circular Stapler Outer Dianeter 25Mm. Inner Diameter 17Mm. No Of Staptes 22 . Open Height 4.8Mm. Fomned Height 2.0 Mm Single Use Circular Stapler Outer Diameter 29Mm, Inner Diameter 21Mm, No Or Staples 26. Open Height 4.8 Mm. Formed Height 2.0Mm — - Single Use Circular Stapler Outer Diameter 3 1Mm, Inner Diameter 23Mm, No Of Staples 28, Open Height 5.0 Mm. -____ Formed Height 2.2 Mm ____ Single Use Circular Stapler Outer Diameter 33Mm, Inner Diameter 25Mm, No Of Staples 32, Open Heipht 5.2 Mni Fonned Height 2.2 Mm .- - 56 Transducer - Open Surgery ( Multi-Use Without Counter Limiuation. ) 57 Transducer - Thorncoscopie ( Mumti-Use Without Counter Limitution. ) — 1 Probe 6Mn Hand Activated Cutting& Coagulating Shears With 36O Degrees Or Shaft Rotation, Capable Or Sealing 58 Blood Vessels Up To 5Mm In Diameter With 36 Cm Shaft Length. Compatible With Existing Rf Generators .Ultrasoni , Generator And Transducer ( Muhi-Use Without Counter Limiaation. ) Or 1 Probe 9 Cm Shaft, Curved, Tapered Tip For Precise Dissection, Seals 5 Mm Vessels, As Well As Lymphatic , 360-Dcgree 59 Shaft Rouarion, Triggers Support Multiple Hand Positions. Compatible With Ultrasonic Generator And Transducer For ( Multi-Use Without Counter Linitation. ) 94 Bronceal Stapler Bovine Pericardlal Bioprosthesis For The Aortlc Position. Fda And European Ce. The Leaflets ( Made From A Single Strip Of Pericardlum ) Are Externally Mounted Over A Titanium Stent And This Allows Complete Opening Of The Leaflets And Aids In Proper Coaptation. Pericardlal Cover On The Stemt Helps In Mi..Gating The Tissue Abrasion With Tissue To Tissue Contact. A Proprety Fixation Procedure Aids In Proper Leaflet Shaping For Proper Leaflet Coaptation. Presence Of Linx Anticalcificatlon Treatment Resists Tissue Calcification And Degradation Of The Valve.Lt Is Avallable In Sizes 19Mm, _____ 2Lmm.23Mm2smm, 27Mm And 29Mm. ___ .I Tissue Heart Valve - Biological Tissue Heart Valves For Mitral And Aorti Heart Position Available In Sizes 19-33Mm Design: Triple Composite Porcune Valves. Valves Have Patented Anti-Calcification Treatment ( Linx Ac Technology ) . I Lowest Profile-9Mm ( Lowest In The Market ) . Sewing Ring Is Made Of Polyester With Markers For Helping In Suturing. 96 Suture-Friendly Cuff Minimizes Suture Drag & Parachuting Forces. Fixation Met1od: Low Pressure Glutaridehyde Fixation. Fiexfit Stent To Reduce Leaflet Stress.The F ) Exflt System Reduces The Rinse Time To 2X10 Seconds. Mitral Ratcheting System Facilitates Insertion Into The Mitral Annulus And Avoids Suture Looping. Scalloped Inflow Surface Optimizes Valve Seating. Usfda Approved. ( Regent Rlex Cuff ) - Aortlc Mechanical Heart Valve- Mechanical Heart Valve For Aortic Position. Individually Sterilized And Ready For Use In Individual Patients. Expiration Date: Five Years From The Date Of Manufacturing. Bi-Leaflet And Rotatable. Supra-Annular Placement. Low Profile.Maximum Protrusion Of Leaflets From The Housing Is 3.4Mm. Minimizes Need For Root Enlargement. Up To 84% Orifice To Annulus Ratio. Single-Digit Pressure Gradients. Opening Angle Of 85 Degrees. Significantly Larger Eoa’S Than Other Mechanical Heart Valves. Significant Reduction In Iv 97 Mass.Disc: Pyrolytic Carbon / Graphite Substrate. Housing: Pyrolytic Carbon / Titanlum With Pyrolytic Aarbon Coating. • Sewing Ring: Made From Polyestpr With Markers For Helping In Suturing. The Flex Cuff Is Flanged And More Ploable Than The Standard Cuff. Patented Butterfly Upstream Pivot Design That Lowers Thrombogenicity, Results In Larger Opening Angles For Improved Laminar Flow And A Reduction In Turbulence Radio Opaque For Improved Visualization During X-Ray And Fluoroscopy. The Valve Is Mri Conditional. Controlled Torque Rotation Mechanism . Available In Sizes 117Mm To 29Mm. U.S Fda Approved And Ce Approved. ______ . Bileaf? Ett Aortic With Conduit -Double-Velour Woven Fabric Offers Excellent Sea Ing Handling And Healing Bileaflet Aortic With Conduit -Double-Velour Woven Fabric Offers Excellent Sealing Handling And Healing Characteristics .Collagen Impregnation Provides Uniform Tissue In-Growth And Biocompatibiity. Rotatable Valve 9 Attached .Auiows For Upstream Placement Of Leaflets Resulting In A Wide Openlng Anwle Enhanced Cuff Configuratcn Offers Excellent Implantability , Conforms To The Annulus, Designed To Minimize Potential For Paravalvular Leak Low Porosity Graft Eliminates The Need For Pre-Clotting And Reduces Surgical Time.No Pleats Allows For Easy Positioni:Ng And Attachment Of Coronaries.Availabie In Sizes: 19Mm To 33 Mm .Us. Fda Approved. Rings Rigid Repair Solutions Available In Rigid Forms. The Rigid Ring Is A Fill 3D Ring Which Creates Natural Saddle Shápe.The Ring Has A Complete Titanium Alloy Core.Mimics Healthy Mitral Anatomy And Provides Full Remodeling Which Reduces Stress. The Ring Helps In Redistributing Leaflet Stress And Chordal Tension And Increases Repair Durability. Encourages Tissue In-Growth Through Use Of Double Velour Polyester Cuff. Racilitates In Suturing With The Ez Suture Cuff Supported By A Unique Trangular Core. Available In Sizes 22Mm To 34Mm. Usfda Pericardial Patch:- Indicated For Cardiac And Great-Vessel Reconstruction And Repair And Pericardial Closure. 2. Designed Should Be For Ease Of Use, Soft, Pliable Tissue Conforms To Uneven Surfaces And Minimizes Suture Hole Icals For More Reliable Repairs. 3. Should Have Encapth Technology, Reduces Adhesions Enabling Easier Re-Access And Structure Idamtif.Cation. 4. Should Have Encap Anti-Calcification Teciuiology To Minimize Calcification And Pronion. Host Endothelializatiorn Resulting In A More Biocompetibie Material. 5. Should Be Glutaraldehyde And Encaptm Technology Tmeated. Bovine Pericardium Resists Shrinkage And Aneurysm Formntion—Potentialiy Reduciag The Chance Ol’ Re-Operation.6. Should Be Rinse Less Preparation, Ready To Use. Nhinner Patch To Accommodnie Pediatric Appiica1ion’. 8. Available Sizes Should Be: 2X5, 5X10, 9X14, 4X5 ...._ ____ Contigra Vascular Mimetic Implant’ For Distal Sfa, Popliteal & Aeross Jomnts’ O18 Nitinol Interwoven Design 4--Lmnn Diameter Various Lengthsupto 200Mm Renal Balloon Expandable Stent Rx .O!4 Compatible Cobalt Chromium 3-3-Multi- Iink Design ‘5 F Compatibie Acm. All Sizes 5, 5.5, 6.6.5 & 7 In Length 12. 15 & 18Mm Usfda Probe 17Cm Shaft, Curved, Tapered Tip For Precise Dissection, Seals 5 Mm Vessels, As Well As Lymphatic. 360-Degree Ol’ 6O Shant Rotation, Triggers Support Multiple Hand Positions. Compatible With Ultrasonic Generator And Transducer ( Multi_ ____? Use Without Counter Limitation. ) — - Probe With Bipolar 6Mm Hand Activated Curved Cutting &Coagulating Shears With 360 Degrees Of Shaft Rotation. 61 Capable Of Sealing Blood Vessels Up To 5Mm In Dianeter With 23 Cm Shaft Length . Compatible With Exiating Rf Generators & Ultrasonic Generator And Transducer ( Multi-Use Without Counter Limitation. ) Which Can Be Used As .___- Both Ultrasonic & Bipolar Laparoscopic Shears. ........ 62 Virofil Smoke, Plume And Pathogen Filter With Universal Luer Lock +3 Luer Caps S3 Nowa 5 Mm, 5-Lomm, 5-12 Mm, Bladeless Trocar W / Viewfinder 100Mm With Virofii. Patbogen Filter ...T 64 Cartidge Small Titanium Red Trans Verac Grooves Heart Shape Wire Usfda Cartdige Of 6 Clip 6S Cartidge Small Titanium Trans Verac Grooves Heart Shape Wire Usfda Cartdige Of 6 Clip . 66 Cartidge Medium Titanium Trans Verac Grooves Heart Shape Wire Usfda Cartdige Or 6 Clip 67 Cartidge Medium-Large Titanium Trans Verac Grooves Heart Shape Wire Usfda Cartdige Or 6 Clip S8 Catdge Large Titaniun Trans Verac Grooves Heart Shape Wire Usfda Cartdige Or 6 Clip —.— 69 Polymer Ligation Clip With Locking Machanism. Cover 3Mm To 16Mm Vessels. Medium Large Class 3 For Ce 70 Polymer Ligation Clip With Locking Machanism. Cover 3Mm To 16Mm Vessels. Large Class 3 For Ce 71 Polymer Ligation Clip With Locking Machanism. Cover 3Mm To 16Mm Vessels. Extra Large Class 3 For Ce - 72 Poliwlecaprone 25 ) Usp Size 3-0 , Suture Lenght 70Cm Needle Length 2S Mm , 3 / 8 Circle Reverse Cutting - Monofilament Poly ( P-Dioxanone ) Uni-Directional With End Loop Barbed Suture, Violet 1 / 2 Circle Taper Point. Usf Size 2-0 , Suture Length 30Cm, Needle Length 37 Mm Undyed, Braided Coated Short Term Poly ( Glycolide-Co-L-Lactide ) ( Polyglactin -910 ) 1 / 2 Circle Taper Cut, Usp Size 2-0 , Suture Length 90Cm , Needle Length 36 Mm Undyed, Braided Coated Short Term Poly ( Glycolide-Co-L-Lactide ) ( Polyglactin -910 ) 1 / 2 Circle Round Bodied, 1 / 2 Circle Reverse Cutting Double Armed , Usp Size 2-0 , Suture Length 140Cm , Needle Length 40 Mm 76 Polyester 1 77 Polyester 2 5 Talc Powder For Pleurodesiss 91 Multi Hole Multipurpouse Catheter Fo Thrombolysis 92 Skin Stapler __ 79 Endoscopic Linear Cutter Stapler 60 Mm Short Shaft ( Open+Thoracic ) - 80 Endoscopic Linear Cutter Stapler 160Mm Standard Shaft ( Regular Laparoscopy ) 81 Endoscopic Linear Cutter Stapler 260Mm Extra Long Shaft 82 Reload 45 Mm White & Blue Endoscopic Linear Cutter Articulating Reload For Vascular Tissue, Staple Height 2.5Mm, 3.5 Mm Reload 60 Mm White & Blue Endoscopic Linear Cutter Articularing For Vascular Tissue, - Staple Height 2.5Mm. 3.5 Mm — Reload 60Mm Gold Endoscopic Linear Cutter Articulating For Medium Thick Tissue, - Staple Height 4.1Mm . 8 Reload 60 Mm Green Endoscopic Linear Cutter Articulating For Thick Tissue, Staple Height 4.8Mm Reload 60 Mm Green Endoscopic Linear Cutter Articulating Ror Extra Thick Tissue. Staple Height 5.0Mm - 86 87 Pre-Fitted With Polyester Sutures : Visual Mark Printed On Polyester For Easy Mesh Centring. 3D Honeycomb Knitted Structure For Superior Tissue Integration And Patient Comfort. Dual Side Mesh With Composition Of Polyester With Polyurethane. Mesh Came With Circular Sizes Also 12Cm And 15Cm Circular. Sizes:69 Icm, 7.6O15cm.10’L5cm, 1S-15Cm, 15-20Cm? Central 4 Lumen Catheter -.—H 88 89 Transperent Dressings Iegaderm 1 90 93 Vascular Stapler Peripheral Balloon Expandable Stem Systen .Otw:O35 Gniewire Compatible. 6F Sheath Compatible Across All Sizes 1O4 ( 7Mm To 10 Mm Dia ) . L-R05 Cobalt Chromium Multi-Link Nt Design. Thin Stmuts Lowest Crimped Profile. Dual- _____ Lnyer._Five-Fold_Hnlloon._Usfdx _____ ________.. Self Expanding Nitinol Stent For Carotid Anwioplasty - Assorted Sizes Rx Tapered Closed Cell Design With Flured Ends. 6F Sheath Compatible Across All Sizes. Freestyle Technology. Usfda 106 Self Expanding Nitinol Stem For Peripheral Angioplasry - Assorted Siaes. . 035 Oiw 6F Sheath Compatible Aeross All Sizes. 135Mm Usable Carheter Length For All Sizes. Triaxial Delivery System With I Beam Technology To Ensure Accunate Stent Placement. Usfda Vascular Closure Device. 5-22F Potypropylene Monofilament Suture Mediated Vessel Closure. With No Re - Access Restriction. Immediate Re-Access Advantage. Flexibility To Pre-Close And Close Over The Wire. For Small Hole And Large Hole Closure Both. Usfda 107 108 — O35 Peripheral Angioplasty Balloon. Crossflex Dual-Layer Balloon Technology. Otw .035 Guide Wire Compatible S 7F Sheath Compatible To 12Mm-L4mm Diameter Faster Deflation. Usable Catheter Lengrh 135Cm For All Sizesdia 4Mm To 14Mm Up To 2S0mm Length. Usfda 109 O14 Peripheral Angioplasty Balloon Crossflex Dual-Layer Balloon Technology. Otw O14 Guide Wire Compatible. 4F Sheath Compatible For Din I.5 To 5 Mn Length Upto 200Mm. Usable Catbeter Length 150Cm For All Sizes.. Ijsd_. 11O .018 Peripheral Angioplasty Balloon. Crossflex Dual-Layer Balloon Technology. Orw 018 Guide Wire Compatible. Sf _____ Sbeath Compatible To Dianeters Fron 2Mn To S.5 Mn. Usable Catheter Length 135Cn For All Siaes .Usfda ___ Carotid Angioplasty Balloon . Ix 0L4 Carotid Balloon. 0I4 Gumde Wire Compatible. Sf Sheath Compatible To 4 To 7 1 Mm Diameter With 20Mm Length Available In Halr Sizes Of Dianeter 4.5 & 5.5. Usable Catheter Length 135Cm For All 9Izes .Usfda 112 105 L ) Isial Embolk Protection Device. One Size For All Carotids. Filter Should Be Indepenthnt Cfvine . Rx .014 61: Slw.Atl, Mpa ( Ihle. 190Cm Bare Wire Workhorse Wire Preloaded Delivery Catheter.Tiniform Micro Pore Siteor 121 ) Nuvrnn Pore Size With I Inni Pore Free Zone. Non-Thrombogenic Nylon Membrane With Hydrophilic Coating. Usfda Clip Based Closure Device-. 5-8 F Nitinol Clip Based Vessel Closure Device. With No Re . Access Restriction. Usfda 114 O35 Extra Support Type Guidewire. Supportive .035 Wire With Soft Atraumatic Tip. 1:1 Torque Response Provides Exceptional Steering. Hydrophobic Coating To Reduce Friction. Wire Lengths Of 190 Cm, And 300 Cm 115 Peripheral Cto Guide Wire. . 014 With Various Tip Load Stiffness From 4.8- 13.0 Mg.. Durasteel Core Material. ! Transitionless Core Taper. Exposed Shap.Bk Tip Coils. Wire Lengths Of I90cm And 300 Cn. — 116 018 Stainless Support Guide Wires. Various Tip Length 3Cn / 5Cn With Shapeable Straight &J Tip.Supportive Stainless Steel Shaft For Excellent Tactile Feedback. 1:1 Torque For Navigation Amound Vessel Bends. 117 1 119 O14 Hybrid Peripheral Guide Wire. Distal Nitinol Tip And Proximal Stainless Steel. Tip Load 2.8 & 3.5G.Ohydrophilic Coating And Radiopaque Polymer Cover. 1:1 Torque For Navigation Around Vessel Bends. Wire Lengths Of 190 Cm Arid 300Cm. 018 Hybrid Peripheral Guide Wire. Distal Nitmol Tip And Proximal Stainless Steel. Tip Load 4G. Hydrophilic Coating And Radiopaque Polymer Cover. Available In Short Taper And Long Taper Both Types Of Tips. Transitiónless Weld Betlen Nitinol And Steel Part. 1:1 Torque For Navigation Around Vessel Bends. Wire Lengths Or 190Cm And 300Cm Peripheral Vascular Plug Multi-Lnyered, Multiple-Lobed Nitinol Mesh Design For Rapid Embolization Within The Vessel4. To Embolize Medium And High-Flow Vessels. Guide Catheter Or Sheath Deliverable: Compatible With 4-7 F Sheaths. Or 5-9 F Guide Catheters Depending On Device Size — Bioprosthetic Heart Valve. Triple Composite Bovine Pericardium With E Lgiloy / Alloy Frame Stent. Should Have Polymer Support Ring Inside The Polyester Knit Fabric For Stent Posts Covering. Should Have Anti Calcification Treatment Done, Should Have Tenting System For Avoiding Suture Looping In Mitral Position. Only Latest Version Is Acceptable. Should Have Sizes For Aortic Position From 19 To 25Mm And For Mitral Position From 25 To 31Mm.Dgci / Ce Approved 120 121 Disposable Bladeless Trocar With Bird Wing Tip Design, 5Mm In Diameter, 95Mm Standard Sleeve Length, Self . Adjusting & Detachable Secondary Seal Which Can Accommodate Instruments Diameter Upto 5Mm 122 Disposable Bladeless Trocar With Bird Wing Tip Design, 1Omm In Diameter, 95Mm Standard Sleeve Length, Self . _____._ Adjusting & Detachable Secondary Seal Which Can Ac Nodate Instruments Diameter Ranging From 5Mm To 1Omm Disposable Bladeless Trocar With Bird Wing Tip Deijj1qiiral Enty Featrre, 12Mm In Diameter, 95Mm Standard 123 Sleeve Length, Self -Adjusting & Detachable Secondiitsjvhich Can Accomnodate Instruments Diameter Rangine From Smmto 12Mm 124 Disposable Bladeless Trocar With Bird Wing Tip Design, 15Mm In Diameter, 110Mm Standard Sleeve Length, Self. Adjusting & Detachable Secondary Seal Which Can Accommodate Instruments Diameter Ranging From 5Mm To 15Mm 125 Ultrasonic Scalpel For Cutting And Coagulating, 36 Cm Shaft Length, 5 Mm Diameter Double Layer Non-Stick ( Teflon ) Coatlng Pad On Jaw. 14Cm / 23Cm / 36Cm / 45Cm 126 Radial Arterial Cannula With Built In Sliding Lock System-Sizes 20 7 Retrograde Cannula Catheter Self -Inflating Smooth Ballon With Pre-Shaped Stylet And Handle 14Fr. Overall Length Should Approx 27Cm & Should Have 18 2Mm Sized Smooth Balloon. Should Be Fda Approved Aortic Perfusion Cannulae: Wire Reinforced Dispersion Tip Sizes: 2Lfr And 24Fr Overall Length Approx. 35Cm And Vent Should Be Us Fda Approved 128 129 P.A. Catheter With 3, Lumens & Color Coding For Each Lumen. Should Be Able To Means P.A. Pressure Flow Directed Insertion & Should Be Supplied With All Accessorises. Like Guld Wire Op Sheath Etc. Bulb Near End Hole. Should Be Us Fda Approved Flo Trac Sensor To Measure Contlonuous Cardiac Output Monitoring ( To Be Compatible With Vigileo / Ev 100O Cardiac Output Monitoring Machine ) Should Be Us Fda Approved - 1 Arterial Transducer For Measuring Invaslve Blood Pressure And Cvp. Should Be Us Fda Approved 132 Disposable Yellow Bulldog Clamp Small Size Of 1-2 Cm With Metallic Spring Good Occluding Capacity. Should Be Us Fda Approved Proximal Aortic Anastomosis Device - It Should Provide The Surgeon With A Stable, Blood Field. It Allows For Up To Three Anastormosis Form One Insertion Site. It Eliminates The Need For Partial Occlusion Clamping During Coronary Artery Bypass Grafting. Size 3.Smm / 4.Omm / 4.5Mm Stemnum And Ribs Lock Plate Should Be Available In Different Sizes And Shapes To Be Supplied With Applier ( Gun ) Sample Based Selection. Should Be Us Fda Apprwved - 135 Stemnum And Ribs Lock Plate 2.4Mm And 2.7Mm Dimaeter Cancellous Self Drilling Locking With Applier. Should Be Available In Different Sizes Sample Based Selection. Should Be Us Fda Approved 136 Ultra High Pressure Non Compllant Pta Dilation Balloon Catheter -High Performance Balloon, Nonc Oomplanntmutiiaayer Balloon With Coaxial Shaft And Working Pressure Range Of Upto 12Atm, Highest Rated Burst Pressure Of 18 Atm Sizes: Diameter ( 12Mm To 26 Mm ) & Lengths ( 2Cm & 4Cm ) With Shaft Lengths Of 75And L2ocms. 1 Netrieval Pvc Filter ( Window Period 3 Day ) -Clinically Tested In Largest Longest Ide Filter Demonstrated Safely Implanted To Provide Immediate Protection Againts Peoptional Ivc Filter, Two Levels Of Filtration With The Legs Aproviding The Lower Level Of Filtration And The Arms Providing And The Arms Providing The Upper Level Of Filtration, Highly Visible Snare Tip Seamlessly Welded To The Body For Easy Filter Retrieval Even After Long In-Dwell Time. The Upper Level Of Filtration 138 I Self Expandable ( Eiectro Pollshed ) With Radlopk Markers- The Stent ( Implant ) Should Equipped With Four Highly Visible Radiopaque Puzzle Tantalum Markers On Both The Proximal And Distal End For Accurate. It Should A Self Expanding Flexible Nitinol ( Nickel-Titanium Alloy ) Stent That Expands To Its Preset Diameter Upon Exposure To Body Temperature. The Stent Has A Segmental Repeating Pattern And An Open Cell Geometry With Flared Ends To Help Prevent Dislocation Or Migration Partial Cuts Around The Circumference Or The Stent Cylinder Provide Enhanced Flexibility And Allow Segment-By Segment Expansion It Should Indicated For The Treatment Of Illiac Occlusive Disease In Patients With Symptomatic Vascular Diseaseof The Common And / Or Externalillac Arteries Up To 126 Mm In Length With A Reference Vessel Diameter Of S To 9Mm Perfect Metalic Length Delivery Thumb Delibery 60-1204 Deployment For Physicians Convenience In Deploying Stent - Trigger, Slide, Combination And Conventional. 133 Self Espending And Popliteal Nitlnol Stent With Unjque Trije Helix Design Structure- Self Expending Usfda Approved For Sfa And Popliteal Stent With Uniqpdçple L$Sdesign Stnucture For Multi-Dimensional Fiexibilty With 139 Unique Delihery System Having Both Thunb Wheel Ñd Pir Fluul Mechanism It Should Sf Vascular Stent System And Intended To Improve Umn Inal Diameter In The Treatment Or Symptomatic De Novo Or Restenostk Lesions Up To 240 Mm In Length In The Native Superficial Femoreal Arterty ( Sfa ) And Popliteal Artery With Reference Vessel Diameters ______ Ranging From 5.0-7.0 Mm Usfda Approved Ultra High Pressure Non Complaint Balloon-It Should For Use In Percutaneous Transluminal Angioplasty Of The Femoral, Iliac And Renal Arteries And For The Treatment Of Obstructive Lesions Of Native Or Synthetic Arteriovenous Diatysis Flstulae. High Performence Balloon Catheter Consisting Of An Overthe-Wire Catheter With A Balloon Fixed At 140 The Distal Tip.The Proprietary Ultr Non-Compliant Low Profile Balloon Is Designed To Provide Consistent Balloon Diameters And Lengths Even At High Pressures.Tow Radiopaque Markers Delineate The Working Length Of The Balloon And Aid In Balloon Placement.The Coaxial Catheter Includes A Tapered Atraumatic Tip To Facilitate Advancement Of The _____ Catheter To And Through The Stenosis Balloon Expandable Vascular Covered Stent -It Should For Treatment Of Atherosclerotic Lesious In Common And External Iliac Arterise With Reference Vessel Diameters Between 4.5 Mm, And 12.0Mm And Lengths Up To 100Mm 141 Balloon Expandable Vascular Covered Stent Should Comprised Of An Electropolished Balloon-Expandable Stent Made From 316L Stainless Steel, Encapsulated Between Two Layers Of Eptfe. The Covered Stent Should Supplied Prem Mounted On An Over-The-Wire Deliveny System With A Non-Compliant Balloon Drug Coated Balioon-Drug Coated Balioon With 2Ug Mm 2 Dose Paditaxble With Polysorbate & Sorbitol As Carrier — Which Will Deliver An Optimal, Therapeutic Drug Dose To The Target Vessel Wall After A Minimum 30 Second Inflation 1 Time Available In Size -O35guidewire Compatible-120 Cm Shaft -4Mm -6Mm Dia, Lenght Upto 150Mm, 035 Guidewire Compatible -75Cm Shaft -5Mm-12Mm Dialength 60Mm 014 Guidewlre Compatible -150Cm Shaft -2Mm To 3.5Mm Dia Length 120Mm Pta Dilatatlon Catheter Semi-Compliant Conslstlng Of An Over The Wire ( Otw ) -Lt Should Semi-Compliant Balloon Catheter Consisting Of An Over The Wire ( Otw ) Catheter With An Arngioplasty Balloon Fixed At The Distal Tip. Two Radiopaque Markers Delineate The Working The Length Of The Balloon And Aid In Balloon Placement Inteded To Dilate -J 143 Drug Coated Balloon-Drug Coated Alloon With 2Ug Mm 2 Dose Paclitaxble With Polysorbate & Sorbitol As Carrier Which Will Deliver An Optimal, Therapeutic Drug Dose To The Target Vessel Wall After A Minimum 30 Second Inflation Time Available In Size -035Guidewire Compatible-120 Cm Shaft -4Mm -6Mm Dia, Ienght Upto 150Mm, 035 Guidewire Compatible -75Cm Shaft -5Mm-12Mm Dia, Length 6Omm 014 Guidewire Compatible -1S0cm Shaft -2Mm To 3.5Mm Dia Length 120Mm .. . Pta Dilatation Catheter Semi-Compliant Consistlng Of An Over The Wire ( Otw ) -Lt Should Semi-Compliant Balloon Catheter Consisting Of An Over The Wire ( Otw ) Catheter With An Angioplasty Balloon Fixed At The Distal Tip. Two Radiopaque Markers Delineate The Working The Length Of The Balloon And Aid In Balloon Placement Inteded To Dilate Stenoses In The Peripheral Arteries To Treat Obstructive Lesions Of Native Or Synthetic Av Fistulae And / Or Re-Expand Endolumlnal Stent Graft Elements In The Iliac Arteries. 3-12 Diameter Range And 20-300 Balloon Length. 144 Pta Oilatation Catheter Semi-Compliant Hydrophydic Balloon Cathater Consisting Of An Our The Wire ( O1w ) - It — Should For Use In Percutaneous Transluminal Angiopiasty ( Pta ) Of The Renal, Popliteal, Tibial Femoral And Peronmeal Arteries. To Facilitate Catheter Advancement Througs The Vasculature And The Viessal Stenosis, Dual Layer Hydrophlic Coating Should Present On The Distal Segment Of The Shaft And The Balloon. 145 • — — 146 Dual Sheath 9Fr And, Ideal For Nc Filter Reetrieval -Dual Sheath 9Fr And I1ir Ideal For Denal Retreval Xink Resistant Nitinol Construction With Radlopaque Loop For Enhanced Visibility 9O Loop Snare For Proper Placement With Precise 1:Ltoeque Facilitates Filter Easy Hook Capture Marker Bands For Accurate Positioning Convenient All-In-Kit Includes New Coaxial Sheaths And Hemostaic Valve Percutaneous Transluminal Valvuloplasty Of The Pulmonary Valve -It Should For Percutaneous Translumin Valvuloplasty Of The Pulmonary Valve In The Following Patient With Isolated Pulmonary Valve Stenosis A Patient With Valvular Pulmonary Stenosis With Other Minor Congenital Heart Disease That Dose Not Require Surgical Intervention The Proprietay Non Compliant Low Profile Balloon Is Designed To Provide Consistent Balloon Diameters And Length Ecen At High Pressure. Ulta High Pressure Non Complalnt Balloon -It Should For Use In Precutaneous Transluminal Angioplasty Or The Peripheral Vasculature Induding The Ilac Arteries And Ilac Femoral Veins And For The Treatment Of Obstructive Lesions Or Synthetic Arteriovenous Dialysis Fistulae A High Performance Balloon Aatheter Consisting Od An Over Thewire With A Balloon Fixed At The Distal Tip The Proprietary Non-Compliant Low Profile Balloon Is Designed To Provide Consistent Balloon Diameters And Lengths Even At High Pressure 1• 143 147 —J Ultra High Pressure Large Volume Inflation Deuie ( Aoml ) -Aijuitra High Pressure, Larhge Volume Inflarion Device Used To Inflate Monitor Pressure And Deflate Angibblasty Bauoon Dilatation Catheters.Lt Should A Onepiece, 30M1 Disposable Inflation Device Rated For 40 Atm With A Leverlock Design That Controls The Piston A Manometer And A 148 High-Pressure Conncting Tube With A Male Luer Rotating Adapter. Also Enclosed Is A High-Pressure 3-Way Stopcock To Aid In Preparation And Use Of The Devlceme Manometer Measures Pressures Ranging From 0 Atm Up To 40 Atm In 1 Atm Increments. The Accuracy Of The Manometer Has Been Determined To Be Within +1.6 Atm. These Products Are _ Not Made With Natural Nubber Latex Flexible Self-Expanding Prosthesis Comprislng Of Dual Layer Eptef Encapsulation With Carbon Impregnation-Flexible Self Expanding Prosthesis Comprising Of Dual Layer Eptef Encapsulation With Carbon Impregnation On Luminal Surfaw To Reduce Intimal Hyperplasla. The Inner Lumen Of Covered Stent ( Blood Contacting Surface ) Is Carbon Impregnated. 149 The Highly And Fracture Rasistant Base Stent Architecture For Tortous Vessel Like Cephalic Arch And Sfa. The Stent Is Availble In Straight And Flared Configurations Avilable From Variety Sizes For Avf And Iliac / Sfa Indication Diameter ( 6- 10Mm ) . Safety Lock System On Delivery System Prevents Premature Release And Two-Wheel Deployment To Ensure ______ Accurate Placement Of Stent At The Lesion Site. No Stent Migration High-Performance Rossing Catheter -High- Performance Catheter In 014W , 018N, 03Sm Platfrom Desigend To Be First 150 Line Aid To Cross Stenotic Lesions And Chronic Occlusions When Standard Wires Fall.Radiopaque Marking System, _...._ Lcmradiopaque Markers Positioned 1 An Apartwityh Doble Markers Dilenate 1Ocn And 20 Cm Self Expanding Nltlnol Stent - It Should Self Expanding Nitional Stent Is Fda Approved For Treament Of Iliac Occlusive Disease In Patients With Symptomatic Vascular Disease Of Mommon Or Exteenal Iliac Arteerise Residual Stenoses Witn 1 Impaired Perfusion Followong Balloon Dilatation- It Should Has Optimized Pin And Pull Delivery System For Precise Placement .High Visibility For Stent Deployment And Relocation Under Fnuroscopy 0.03S Guidewire Compatible, — Diameter Sizing Of Stent To Target Lesion Reouces Stent Migration Self Expandable Cover Stem Graft, Dual Layer Eptfe- It Should Vascular Stent Graft Is Used In Resldual Stenosis With Impalred Perfusion Following Balloon Dilation Especially In Stages Ill & Iv According To Rontaine Dissection; Detached Arteriosclerotic Olaaue Material Luminal Obstruction Foliowinu Balloon Dilatation Occlusion After Thrombolvsis Or Self Expandable Cover Stent Graft, Dual Layer Eptfe- It Should Vascular Stent Graft S Used In Residual Stenosis With Impaired Perfusion Following Balloon Dilation Especially In Stages Ill & Iv According To Fontaine Dissection, Detached Arteriosclerotic Plaque Material Luminal Obstruction Following Balloon Dilatation Oxclusion After Thrombolysis Or 152 After Aspiration Or Diatation Restenosis Or Re-Occlusion Proven Dual Layer Eptfr Encapsulation Demonstrated A Significant Reduction At 90 Day In The Incidence Of In Stent Restenosis Compared To Pta Proprietary Bioactive Carbon Impregnation Designed To Reduce Early Stage Platelet Adhesion Rlexible Implant That Demonstrated Kink Resistance Placement In Tortuos Lesions Presenting With In-Stent Restenosis Or Non Stented In Patients Mufticonnecting Tube With 150 Cm Tube For Connecting To The Patient End. 2 Nos 100Cm Connecting Tube With Drip 1S3 Chamber To Connect To The Contrast And Saline Bottles / Pack And 2 Cormnectors For Connecting The 2 Syringes In The ____ Dual Head Injector System. 154 Custom Made Pressure Garment Below Knee Stockings Palr. . 155 Custom Made Pressure Garment Full Knee Stockings Pair. -._.___G 1S6 Custom Made Pressure Garment Fore Arm Custom Made Pressure Garment Full Arm 158 Custom Made Pressure Garment Fore Arm With Guantlet 1S9 Custom Made Pressure Garment Full Arm With Guantlet 16O Tegaderm Chg Clorhexedine Gluconate Iv Securement Oressing 1657R 161 Tegaderm Cig Clorhexedine Gluconate Iv Securement Dressing 166Cr Sterile Collagen Sheets In Wet & Meshed Form. Pure Type 1&3 Triple Helical Membrane Bovine Origin Preserved In 162 A Mixture Of Iso Propyl Alcohol And Water Gamma Sterilized And Supp.Ed In Double Sterile Pouches. Biocompatible Sterile Collagen Sheets In Wet & Meshed Form. Pure Type 1&3 Triple Helical Membrane Bovine Origin Preserved 163 In A Mixture Of Iso Propyl Alcohol And Water Gamma Sterilized And Supplied In Double Sterile Pouches. - Biocompatible As Per Iso 9O01 / Ls01348snn Loxlo 4- .C- Sterile Collagen Sheets In Dry Form. Pure Type 1&3 Triple Helical Membrane Bovine Origin Gamma Sterilized And ________... Supplied In Double Sterile Pouches. Biocompatible As Per Rso9oo1 / 1S01348s N 10*1O -- 165 Sterile Collagen Sheets In Dry Form. Pure Type 1Nelical Membrane Bovine Origin Gamma Sterilized And ____-_______ Supplied In Double Sterile Pouches. Biocompatible As Per Iso 90O1 / 15013485 N 10*20 __... Sterile Peru S Collagen Sheet In Dry Form ( Fish Origin ) 10*10 Cm 167 Sterile Porus Collagen Sheet In Dry Form ( Fish Origin ) 8 X 12 168 Silicone Sheet Pure Poly Siloxane Based Silicone Scar Management Product In Sheet Form. 1Oxlo 16E Biofil Ab Sterils Medicated Collegan Partiules S Ml 170 Biofil Ab Sterlls Medicated Collegan Particles 1O Ml Lipido-Colloid Contact Layer Impregnated With Silver Salts Urgotul Ag Silver Sterile Non-Occulusive Wound Contact Layer 171 Consists Of Silver Healing Matrix Made Of Polyester Mesh Impregnated With Hydrocollold Particles ( Cmc ) , Petroleum Jelly Polymers And Silver Sahts With Demonstrated In Vitro Antibacterial Activity Upto 7 Days, Using Patented - Lipido- Colloid Technology 10X12 Lipido-Collold Contact Layer Impregnated With Silver Salts Urgotul Ag Silver Sterile Non-Occulusive Wound Contact Layer 172 Consists Of Silver Healing Matrix Made Of Polyester Mesh Impregnated With Hydrocolloid Partlcles| Cmc ) , Petroleum Jelly, Polymers And Silver Salts With Dernonstrated In Vitro Antibacterial Activity Upto 7 Days, Using Patented .. Uipido- Colloid Technology 15X20 - Lipido-Colloid Foam Dressing With Adhesive Border Urgotul Sterile Self -Adherent Patented Ftc Matrix ( Lipido Colloid 173 Technology ) Wound Contact Layer Combined With Absorbent Polyurethane Foam Pad, A Superabsorbent Layer , A Vapour Pemmeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing. 13*13 Lipido-Colloid Foam Dressing With Adhesive Border Urgotul Sterile Self -Adherent Patented Ntc Matrix ( Lipido Colloid 174 Technology ) Wound Contact Layer Combined With Absorbent Polyurethane Foam Pad . Superabsorbent Layer .A Vapour Permeable Waterproof Outer Film With Soft Sillcone Adhesive Border On The Edges For Atraumatic Removal And _. Repositioninr Of Dressing. 15*20 . 175 Lipido-Collold Foam Dressing With Adhesive Border Urgotul Sterile Self -Adherent Patented Tlc Matrix ( Lipido Colloid Technology ) Wound Contact Layer Combined With Absorbent Polyurethane Foam Pad , A Superabsorbent Layer , A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And 176 Cabg Kit Off Pump ( Annexure 1 ) 177 Single Valve Surgery Kit ( Annexure 2 ) 178 Asdivsd Kit ( Annexure3 ) Dry Suction Wet Seal With Air Flow Capacity Of I6lpm. Should Maintain Suction Level Of ( 4O ) ( -43 ) C.M.Should Have Single Chamber With Capacity Of 25Oml 179 180 Dacron Graft 6X20 / 30-Dacron Graft 6X40 Dacron Graft 6X40 / 60-Dacron Graft 6X60 181 — 182 83 Dacron Graft 7X20 / 30-Oacron Graft 7X40 Dacron Graft 7X40 / 60-Dacron Graft 7X60 84 Dacron Graft 8W40 / 60-Dacron Graft 8X40 184 Prfe Graft 4X40-Ptfe Graft 4X1o . - Ptfe Graft 5X20-Ptfe Graft Sx1o Ptfe Graft 8X40 / 50-Ptfe Graft 8X4.0 Embolactomy Aatheter 185 186 187 188 189 Cartidge Snall Titanium Red Trans Verae Grooves Heart Shape Wire Usfda Cartdige Or 6 / 9Clip --._ - Cartidge Small Titanium Trans Verac Grooves Heart Shape Wire Usfda Cartdige Of 6 / 9Clip 190 — Cartidge Medium Titaniun Trans Verac Grooves Heart Shape Wire Usfda Cartdige Of 6 / Qclip 191 - Cartidge Medium-Large Titanium Trans Verac Grooves Heart Shape Wire Usfda Cartdige Of 6 / 9Clip 192 Cartidge Large Titanium Trans Verac Grooves Heart Shape Wire Usfda Caitdige Of 6F9clip Ptfe Graft 1Ox9ocm Dacron Graft 8X80 / 70 - Ptfe Patches Lox9omm, 0.4Mm Thickness . 193 - 194 195 CABG OsF Pump 1 Chest Tube 2 ACTTube 3 CD Bottle 4 Cautry pencil 5 Cautry Plate 6 Urometer 7 loban 8 Respirometer 9 Bureta set 10 Veinonlinee — 11 Coronary shunt 12 V Conector 13 AVTubing 14 Suction line — i Pledget Foil 16 Vessel can ula 17 CARDIAc SUMP 18 Powder free g’oves 19 NSPouch 20 — Papavarin 21 Phempress . Mister blower 22 23 Buldog clamp 24 Yellow buldog 25 Cardlotomy Resorvior - 26 chest binder 27 Cardiotomy Resorvior circuit 28 Hemostat 9A ortic? punch -- 0 Scratch Pad 25x25 - 31 Protamin 32 Lap pad 7x7 33 Crusent Knife 34 Multiple y Adoptor 35 Balance salt solution (SOOrnI) 36 Pledget foil 37 Lap pad 7x7cm 38 3-Wav adapter S.NO sinne valve surgery kIt Qty. 1 Oxyienator heprn coated 1 2 Custom tublr pack 1 3 Cardioplegia dellvery system 1 4 Arterial filter 1 - 5 chesttube 2 - 6 7 CDbottle 1 ACT Tube 6 8 Cautry pencil 1 9 10 11 12 cautry plate______________ 1 Unometer loban Steridrape 1 1 1 - 13 • 15 Buretta 1 Bulb syrirwe 1 veIn o line Yconector 2 3 16 17 Av Tubing 2 18 Arch canula 1 2 19 venous canula - 20 Chest binder 1 21 22 Sump 1 Powder free gloves 5 -- 23 P45Pouch 2 24 Pleglogard m 3 25 Phempress 2 26 High Pressure Line 200 cm 3 27 Purge Line 1 28 Multipte y Adoptor 1 Scrasatch pad 25x2s 1 30 Protamin 5 31 Balance salt solution 3 32 Pledget foil 1 33 level sensor 1 34 Lappad7x7 — 25 35 Root canula 1 S.NO. AsD/VSD kit Qty. 1 Oxygenator heprin coated — 1 2 Custom tubing pack 1 — 3 Cardiople8ia delivery system 1 4 Arterial.filter 5 chest tube 3 6 CDbottle 1 7 8 ACTTube 6 -m-T 1 cautrypencil 1 9 Cautryplate Unometer 1 1 — L 1o 11 loban 1 - 12 - Steridrape 1 13 Buretta 1 14 1b Vein o line Yconector 2 3 AVTubinj 2 17 Arch canula I 18 Venous canula 2 19 Chest binder 1 20 vent canula 1 h-—----- - 21 Powder free glove. 5 22 .. NSPouch 2 23 Plegiogard 3 24 Phempress 2 25 Protamin 3 — 26 Purge line 1 e. ae I —.—? 27 Scratch pad 28 Hemostat 29 Plleclget foil Balance salt solution 31 Root canula 1 1 1 3 1, 32 33 Hifg pressure Line 200 cm — 3 level Sensor 1 - - 34 35 AukIine activator — Lappad7x7 — 1 25 — 36 Under water seal drain 1 etc