| 1 | Replacement of Street Light with LED Street Light and Garden Light atDevgad Lighthouse - ANNEXURE – I |
| 2 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and comissiong etc. as required. |
| 3 | Double pole 6A |
| 4 | Providing, laying and fixing 80mm dia G.I. pipe (medium class) in ground complete including trenching (75cm deep) and re-filling etc., as required(for CC road crossing) |
| 5 | Supply of outdoor 25Watt SMD LED Chip as per LM 80/ISI6106 (LED PT Module 0.5 to 1 Watt) top Die cast Aluminum and Bottom Die Cast Aliminum with higher thermal conductivity IP66 protection of 70mm pipe entry for Garden Light. |
| 6 | Supply and laying of 3core X 2.5sqmm copper amoured PVC insulated /PVC sheathed XLPE power cable as required (Laying from Power house to static Sensor Compound and laying for 2 Nos gate light, 4 Nos. street lights) |
| 7 | Supply of 2.5 Sqmm cable gland |
| 8 | Supply and installtion 3\" Dia Class \"C\" GI pipe 4 meter Length (as per drawing) alongwith applying 1 coat primer and 2 coat aluminium paint. |
| 9 | Supply and Installtion of 1\" threaded 45 degree bend pipe 1 meter length alongwith applying 1 coat primer and 2 coat aluminium paint. |
| 10 | Supply and Installation of 3\" to 2\" GI reducer alongwith applying 1 coat primer and 2 coat aluminium paint. |
| 11 | Supply and Installation of 2\" threadedpipe 1.5 feet length alongwith applying 1 coat primer and 2 coat aluminium paint. Suitable for Garden Light |
| 12 | Supply and Installation of 3\" to 1\" GI reducer alongwith applying 1 coat primer and 2 coat aluminium paint. |
| 13 | Supply and fixing of SMC Pole mounted Junction Box (200X140X95mm)with side hinged door, IP55 with necessary clamps/ Strip, SS screws/Nut and blot, etc., (5 nos for street light and 1 nos for gate light) |
| 14 | Supplying and laying of 3 Core 1.5 Sqmm PVC Copper cable(from street light fitting to jn box) |
| 15 | Supply and fixing 11/2\" PVC HDPE flexible(Hard) pipe Thickness aprox 3mm hard pipe (To fixing foundation for laying cable from under ground to junction box) |
| 16 | Supply of 1 Phase street light timer |
| 17 | Supply of PVC enclosure for fixing street light timer |
| 18 | Making cable trench in rockey area for laying cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 19 | Electrician (Labour) Charges for wiring of streelights, and fitting luminaries, timer, etc., |
| 20 | Base of Streetlights: Earthwork Excavation in beach area(staff Qtrs compound) and take out water during excavation (0.6 x 0.6 x 0.5m) for the foundation of steeetlight, 1:2:4 (1 cement : 2coarsesand:4gradedstoneaggregate20mmnominalsize)ConcreteWork(0.6x0.6x0.5m)forthe foundation with Post pipe placed in concrete inclusive of materials, Brick Work (0.45 x 0.45 x 0.45m)for post base and placing of pipes forcable entry, Plastering Work (4 x 0.45 x 0.45) +(0.45 x 0.45) for post base and Painting Work applying 1 coat White primer Paint and 2 coat Synthtic enamel Red Paint.(4 x 0.45 x 0.45)+(0.45x 0.45) |
| 21 | Labour charges for dismentaling of old street lights |
| 22 | Miscellaneous items for the purchase of SS bolt, PVC grip, insulation tape etc |
| 23 | Rewiring of Lighthouse tower at Devgad |
| 24 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required |
| 25 | 3 x 1.5 sq. Mm (for fan and light points in service room and tower bottom) |
| 26 | 3 x 2.5 sq. mm(From DB to Switch Board) |
| 27 | 4 x 1.5 sq. mm(for staricase wiring From LH tower bottom to service room) |
| 28 | 3 x 4 sq. mm ( Laying from tower bottom To Service room) |
| 29 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 30 | 5/6A switch |
| 31 | 2 way 5/6 A switch |
| 32 | 15/16 A switch |
| 33 | 3 pin 5/6 A socket outlet |
| 34 | 6 pin 15/16 A socket outlet |
| 35 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 36 | 1 or 2 Module (75mmX75mm) (PVC) (for Wall mounted fan) |
| 37 | 6 Module (200mmX75mm) |
| 38 | 12 Module (200mm * 150mm) (PVC) |
| 39 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 40 | Supplying and fixing PVC batten / angle holder including connections etc. as required. (1 for lantern room) |
| 41 | Switch gear and DB |
| 42 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 43 | Single pole 6A(1 Nos for service room)(1 No for LH bottom) |
| 44 | Single pole 16A (1 Nos for service room)(1 No for LH bottom) |
| 45 | Double pole (6A)(LH Service room) |
| 46 | Supplying and fixing following rating, double pole, 240 V, isolator in the commissioning etc. as required. existing MCB DB complete with connections, testing and and commissioning etc. as required. (at service room and LH bottom) |
| 47 | 40 A (1 No for Service room, 1 No for LH bottom stair case) |
| 48 | Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (at service room and LH bottom) |
| 49 | 40 A (1 No for Service room, 1 No for LH bottom stair case) |
| 50 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. |
| 51 | 8 way, Double door (1 Nos LH tower Service room)(1 No for LH bottom) |
| 52 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 53 | Supply of Indoor Industrial Tube Light Battens, with LED Tube (inclusive), LED Batten with Essential 4\" 22W LED tube. (refer Sl No. 2.027 for installation) |
| 54 | Supply of 10W LED Bulk Head Luminaries IP65/66/67 LED Light source (inclusive) with integrated LED source. |
| 55 | Supply of LED LAMP 12W(Base B22 12-Watt LED Bulb)dimmable Master LED Glass Bulb (refer Sl No.2.027 for installation) |
| 56 | Supply of Wall Mounting Fan, 400 millimeter Bracket mounted fan for Wall mounting (Mist Air Duos) Hi-Speed, |
| 57 | Supply of 32X 12.5mmDLP mini trucking system each 2.1 mtr length each(for stiar case light wiring including vertical and horizontal fixing of trunking double run) |
| 58 | Supply and laying of 3core X 2.5 Sqmm Copper armoured PVC insulated/PVC sheathed XLPEpower cable as required.(fromPower house to Lighthouse bottom for stair case lightning) |
| 59 | Supply and laying of 3core X 4 Sqmm Copper armoured PVC insulated/PVC sheathed XLPEpower cable as required.(fromPower house to Lighthousebottom for main lightning double run, one in service another one is spare) |
| 60 | Supply of Bare Copper wire, 8 SWG earth wire |
| 61 | Laying of 8 SWG copper wire from earth pit to LH tower bottom DB. |
| 62 | Laying & fixing of cable duct vertical run for power wire and vertical and horizontal run for Stair case Light |
| 63 | Making cable trench for laying cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.(For laying three numbers cable from power house to tower botton. Rocky area) |
| 64 | Making earth pit charges(additional) of Sl No.2.04 for Lighthouse located at hill & rocky area diffcult to digging earth pit(heavy duty machinary and labour charges) |
| 65 | Miscellaneous items for the purchase of S.S screws and washer(for fixing cable duct), drill bits, fishers(heavy wall plugs) 250mm cable ties, SS \"U\" Clamps, flexible pipes, etc., |
| 66 | Provision of additional Electrode earthing for Generator at Devgad Lighthouse - ANNEXURE – III |
| 67 | GCE 86- Supply of GRAVIN Earth Electrodes, Copper Electrode 80 mm dia wall thickness 1.60 mm, 6 meter long, inner space of pipe filled with high conductive material along with 8 bag (25Kg to a bag) of Earth RITE Compound. |
| 68 | Supply of UG 1 core x 35 Sq.mm flexible copper conductor cable laying from earth pitto Generator |
| 69 | Supply of Bare Copper wire, 8 SWG earth wire for connecting between earth pit to Generator neutral and body |
| 70 | Labour charges for making bore for of 6\" dia x 20 feet depth forproviding electrode earthing. The Lighthouse located rocky area diffcult to digging earth pit. Using compressor driller for making earth pit. |
| 71 | Labour charges for making Masonary enclosure with lid and connections between earth pit ad generator . |
| 72 | Miscellaneous items for the purchase of S.S bolts, nuts, sleeves, sockets, cotton tapes etc. |