Group-A -Design, Supply, Installation And Commissioning Of Dc Power System Comprising Battery Charger, Solar System, Battery Bank At Unmanned Rcp / Sv Locations Of New Mppl, P-25 Pipeline Project In The State Of Gujarat, Rajasthan, And Hary, NOIDA-Uttar Pradesh

Indian Oil Corporation Limited-IOCL has published Group-A -Design, Supply, Installation And Commissioning Of Dc Power System Comprising Battery Charger, Solar System, Battery Bank At Unmanned Rcp / Sv Locations Of New Mppl, P-25 Pipeline Project In The State Of Gujarat, Rajasthan, And Hary. Submission Date for this Tender is 12-09-2022. Battery Chargers Tenders in NOIDA Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33415198
Corrigendum : Group-A -Design, Supply, Installation And Commissioning Of Dc Power System Comprising Battery Charger, Solar System, Battery Bank At Unmanned Rcp / Sv Locations Of New Mppl, P-25 Pipeline Project In The State Of Gujarat, Rajasthan, And Hary
Open Tender
Indian
Uttar Pradesh
NOIDA
12-09-2022

Tender Details

Group-A -Design, Supply, Installation And Commissioning Of Dc Power System Comprising Battery Charger, Solar System, Battery Bank At Unmanned Rcp / Sv Locations Of New Mppl, P-25 Pipeline Project In The State Of Gujarat, Rajasthan, And Haryana Group-A -Design, Supply, Installation And Commissioning Of Dc Power System Comprising Battery Charger, Solar System, Battery Bank At Unmanned Rcp / Sv Locations Of New Mppl, P-25 Pipeline Project In The State Of Gujarat, Rajasthan, And Haryana

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Aug-2022 ADDENDUM-01 Technical Bid 05-09-2022
2 06-Sep-2022 Addendum-2 Date 12-09-2022

Key Value

Document Fees
Refer document
EMD
INR 675000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: GROUP-A Part I: Design, Supply, Installation and Commissioning of DC power system comprising Battery Charger, Solar System, Battery bank at unmanned RCP/SV locations of New MPPL (P-25) Pipeline Project in the state of Gujarat, Rajasthan, and Haryana. PART-II Comprehensive Annual Maintenance for 5 years along with resident engineer after completion of defect liability period comprising of all system as per PART-I GROUP-B Part I: Design, Supply, Installation and Commissioning of DC power system comprising Battery Charger, Solar System, Battery bank, Small Wind Turbine system at 01 no. of unmanned RCP location of New MPPL (P-25) Pipeline Project in the state of Rajasthan. PART-II Comprehensive Annual Maintenance for 5 years along with resident engineer after completion of defect liability period comprising of all system as per PART-I
Sl. No. Item Description
1RATE OF GST APPLICABLE FOR ALL ITEMS OF THE BOQ CONSIDERING JOB AS COMPOSITE SERVICES. BIDDER TO SELECT ONE GST RATE FROM THE DROP DOWN LIST
2DC POWER SYSTEM-GROUP-A-GUJARAT
3A Supply
4Hybrid Battery Charger (provision for AC & solar power as inputs), AC to DC rectifiers for 230V AC/ 48V DC, 125 A + 25 A (SMPS based) in n+1 configuration i.e. 5+1 = 6 nos, minimum 25A modules as per specifications; where n is the no. of AC to DC rectifier modules required to meet load capacity of 125A as per specifications (SOR item for solar power system is mentioned separately) . The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.
5Tubular Lead Acid OPzS type Battery 48V DC, 600 AH along with battery stand & accessories, as per specifications
6Tubular Lead Acid OPzS type Battery 48V DC, 800 AH along with battery stand & accessories, as per specifications
7Hybrid Battery Charger (provision for AC & solar power as inputs), AC to DC rectifiers for 230V AC/ 48V DC, 75 A + 25 A (SMPS based) in n+1 configuration i.e. 3+1 = 4 nos, minimum 25A modules as per specifications; where n is the no. of AC to DC rectifier modules required to meet load capacity of 75A as per specifications (SOR item for solar power system is mentioned separately) . The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.
8Tubular Lead Acid OPzS type Battery 48V DC, 400 AH along with battery stand & accessories, as per specifications
9Resistive DC load ( 48V/100A)
10Portable gravity fed emergency eye washer system
11Solar System forRCP Locations (Capacity 6 KWp) as per specifications
12Solar System for IndependentSV Locations (Capacity 3 KWp) as per specifications
13Electronic Perimeter Security System (Power Fencing) for Solar Panels at RCP/ CP+MOV/MOV locations as per tender specifications
14Installation Materials for DC power system, charger,battrey bank, solar panel, AC/ DC Distribution Boxes (ACDBs/ DCDBs), MCBs/ Isolator Switches, Power Distribution Boards,power cables for input power supply to Battery Charger, required cables for taking power supply from Owner"s ACDB/distribution / Battery Charger to equipments, required cable from Solar panel to Array junction box to battery charger,all requiredInstallation Material includingPVC/GI conduits, casing pipes, clamps, screws etc. as per specifications
15Set of spares for Battery Charger as per specifications comprising - i) SMR Module (4 Sets) ii) Monitoring, Controller Module(2 Sets) iii) Display Module (2 Sets) iv) Any other OEM specific Electronic Card (2 Sets) v) All types of Contactors & Fuses (4 Sets)
16Set of spares for Solar Charge Controller as per specifications comprising - i) Solar Charge Controller Module (4 Sets) ii) Any other OEM specific Electronic Card (2 Sets)
17Sick Cell 2V Charger for Lead Acid Tubular OPzS Battery as per specifications
182V Spare Cell in dry condition forTubular Lead Acid OPzS type Battery of600 AH as per specifications
192V Spare Cell in dry condition forTubular Lead Acid OPzS type Battery of 400 AH as per specifications
20B Services
21Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including solar panel, DCDB, cabling etcat Independent SV/ MOV Stations, CP+SV/ RCP station, dismantling of existing system (as mentioned for RCP Nagalpur & Churwa in the tender) as per scope and specifications of tender.
22DC POWER SYSTEM-GROUP-A- RAJASTHAN
23A Supply
24Hybrid Battery Charger (provision for AC & solar power as inputs), AC to DC rectifiers for 230V AC/ 48V DC, 125 A + 25 A (SMPS based) in n+1 configuration i.e. 5+1 = 6 nos, minimum 25A modules as per specifications; where n is the no. of AC to DC rectifier modules required to meet load capacity of 125A as per specifications (SOR item for solar power system is mentioned separately) . The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.
25Tubular Lead Acid OPzS type Battery 48V DC, 600 AH along with battery stand & accessories, as per specifications
26Resistive DC load ( 48V/100A)
27Portable gravity fed emergency eye washer system
28Solar System forRCP Locations (Capacity 6 KWp) as per specifications
29Electronic Perimeter Security System (Power Fencing) for Solar Panels at RCP/ CP+MOV/MOV locations as per tender specifications
30Installation Materials for DC power system, charger,battrey bank, solar panel, AC/ DC Distribution Boxes (ACDBs/ DCDBs), MCBs/ Isolator Switches, Power Distribution Boards,power cables for input power supply to Battery Charger, required cables for taking power supply from Owner"s ACDB/distribution / Battery Charger to equipments, required cable from Solar panel to Array junction box to battery charger,all requiredInstallation Material includingPVC/GI conduits, casing pipes, clamps, screws etc. as per specifications
31Set of spares for Battery Charger as per specifications comprising - i) SMR Module (4 Sets) ii) Monitoring, Controller Module(2 Sets) iii) Display Module (2 Sets) iv) Any other OEM specific Electronic Card (2 Sets) v) All types of Contactors & Fuses (4 Sets)
32Set of spares for Solar Charge Controller as per specifications comprising - i) Solar Charge Controller Module (4 Sets) ii) Any other OEM specific Electronic Card (2 Sets)
33Sick Cell 2V Charger for Lead Acid Tubular OPzS Battery as per specifications
342V Spare Cell in dry condition forTubular Lead Acid OPzS type Battery of600 AH as per specifications
35B Services
36Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including solar panel, DCDB, cabling etcat Independent SV/ MOV Stations, CP+SV/ RCP station as per scope and specifications of tender
37DC POWER SYSTEM-GROUP-A-HARYANA
38A Supply
39Hybrid Battery Charger (provision for AC & solar power as inputs), AC to DC rectifiers for 230V AC/ 48V DC, 125 A + 25 A (SMPS based) in n+1 configuration i.e. 5+1 = 6 nos, minimum 25A modules as per specifications; where n is the no. of AC to DC rectifier modules required to meet load capacity of 125A as per specifications (SOR item for solar power system is mentioned separately) . The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.
40Tubular Lead Acid OPzS type Battery 48V DC, 600 AH along with battery stand & accessories, as per specifications
41Hybrid Battery Charger (provision for AC & solar power as inputs), AC to DC rectifiers for 230V AC/ 48V DC, 75 A + 25 A (SMPS based) in n+1 configuration i.e. 3+1 = 4 nos, minimum 25A modules as per specifications; where n is the no. of AC to DC rectifier modules required to meet load capacity of 75A as per specifications (SOR item for solar power system is mentioned separately) . The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.
42Tubular Lead Acid OPzS type Battery 48V DC, 400 AH along with battery stand & accessories, as per specifications
43Resistive DC load ( 48V/100A)
44Portable gravity fed emergency eye washer system
45Solar System forRCP Locations (Capacity 6 KWp) as per specifications
46Solar System for IndependentSV Locations (Capacity 3 KWp) as per specifications
47Electronic Perimeter Security System (Power Fencing) for Solar Panels at RCP/ CP+MOV/MOV locations as per tender specifications
48Installation Materials for DC power system, charger,battrey bank, solar panel, AC/ DC Distribution Boxes (ACDBs/ DCDBs), MCBs/ Isolator Switches, Power Distribution Boards,power cables for input power supply to Battery Charger, required cables for taking power supply from Owner"s ACDB/distribution / Battery Charger to equipments, required cable from Solar panel to Array junction box to battery charger,all requiredInstallation Material includingPVC/GI conduits, casing pipes, clamps, screws etc. as per specifications
49Set of spares for Battery Charger as per specifications comprising - i) SMR Module (4 Sets) ii) Monitoring, Controller Module(2 Sets) iii) Display Module (2 Sets) iv) Any other OEM specific Electronic Card (2 Sets) v) All types of Contactors & Fuses (4 Sets)
50Set of spares for Solar Charge Controller as per specifications comprising - i) Solar Charge Controller Module (4 Sets) ii) Any other OEM specific Electronic Card (2 Sets)
51Sick Cell 2V Charger for Lead Acid Tubular OPzS Battery as per specifications
522V Spare Cell in dry condition forTubular Lead Acid OPzS type Battery of600 AH as per specifications
532V Spare Cell in dry condition forTubular Lead Acid OPzS type Battery of 400 AH as per specifications
54B Services
55Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including solar panel, DCDB, cabling etcat Independent SV/ MOV Stations, CP+SV/ RCP station as per scope and specifications of tender
56AMC-GROUP A-GUJARAT
57Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work
58AMC Charges for 1st Year
59AMC Charges for 2nd Year
60AMC Charges for 3rd Year
61AMC Charges for 4th Year
62AMC Charges for 5th Year
63AMC-GROUP A-RAJASTHAN
64Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work
65AMC Charges for 1st Year
66AMC Charges for 2nd Year
67AMC Charges for 3rd Year
68AMC Charges for 4th Year
69AMC Charges for 5th Year
70AMC-GROUP A-HARYANA
71Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work
72AMC Charges for 1st Year
73AMC Charges for 2nd Year
74AMC Charges for 3rd Year
75AMC Charges for 4th Year
76AMC Charges for 5th Year
77DC POWER SYSTEM-GROUP-B
78A Supply
79Hybrid Battery Charger (provision for AC & solar power as inputs), AC to DC rectifiers for 230V AC/ 48V DC, 125 A + 25 A (SMPS based) in n+1 configuration i.e. 5+1 = 6 nos, minimum 25A modules as per specifications; where n is the no. of AC to DC rectifier modules required to meet load capacity of 125A as per specifications (SOR item for solar power system is mentioned separately) . The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.
80Lithium Ion (Lihtium Ferrous Phosphate) battery bank : 48V DC, 2200 AH with Battery Management System including all installation materials and interconnecting cables along with battery cabinet & accessories, as per specifications. Overall battery bank capacity is to be bifurcated into 02 nos. of 1100 AH battery bank with separate charge controllers system for each 1100 AH battery bank capacity as per technical specifications.
81Portable gravity fed emergency eye washer system
82Solar System forRCP Locations (Minimum Solar panel Capacity 16.3 KWp & minimum Solar charge controller capacity of 9 x 2 KW=18 KW) as per specifications
83Electronic Perimeter Security System (Power Fencing) for Solar Panels at RCP/ CP+MOV/MOV locations as per tender specifications
842 KW Wind Turbine including permanent magnet generator, rotor blades set ,tail vane, etc MNRE Approved Make (including all required materials and accessories to meet tender requirement)
85Charge controller along with control panel for 2 KW Wind Turbine system, other auxillaries such as Dump load, capacitor etc, MNRE Approved Make(including all required materials and accessories to meet tender requirement) to be provided as per tender specifications.
8618 meter/ 60ft. ground Triangular Welded Guyed Lattice tower with guy ropes, hardware, accessories & with galvanization as per tender technical specifications
872 KWPower inverter for conversion of -48VDC to 230VAC (1-Phase) supply
88Installation Materials for DC power system, charger,battrey bank, solar panel, Small Wind turbine system, inverters, AC/ DC Distribution Boxes (ACDBs/ DCDBs), MCBs/ Isolator Switches, Power Distribution Boards,power cables for input power supply to Battery Charger, Solar system to Solar charge controller, Small wind turbine to Wind charge controller to DCDB, DCDB to inverter, DCDB to battery bank/ loads, inverter to AC loads, required cables for taking power supply from Owner"s ACDB/distribution / Battery Charger to equipments, required cable from Solar panel to Array junction box to battery charger, Small wind turbine system to wind charge controller to DCDB, all requiredInstallation Material includingPVC/GI conduits, casing pipes, clamps, screws etc. as per specifications
89B Services
90Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including solar panel, DCDB, cabling etcat Independent SV/ MOV Stations, CP+SV/ RCP station as per scope and specifications of tender
91Installation & Commissioning charges for Small Wind Turbine as per tender specifications
92AMC-GROUP-B
93Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work
94AMC Charges for 1st Year
95AMC Charges for 2nd Year
96AMC Charges for 3rd Year
97AMC Charges for 4th Year
98AMC Charges for 5th Year