Public Health Engineering Department has published a tender for Execution Testing, Commissioning Of Pumping Machinery , Etc In 749 Villages, Including 10 Years Ond M Under Nonera Wsp Under Jjm District Kota And Bundi. ( Package-Ii ) . Submission Date for this Tender is 06-09-2022 and Tender estimated value is 8319700000. Pump Supply Tenders in kota Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 12-Aug-2022 | corrigendum 01 | Technical Bid | 06-09-2022 |
FileName | File Description | File Size |
0ee33d56-87b5-4e44-a4b1-b0b9b9bdb2fe.html | Tender Notice | 45.0 KB |
BOQ_515224.xls | Tender Document | 1.3 MB |
TD13.pdf | Tender Document | 21.9 MB |
Tendernotice_1.pdf | Tender Document | 1.4 MB |
Sl. No. | Item Description |
1 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil |
2 | Add extra for trenches for every additional lift over item no 4.1 |
3 | Above 1.5 mtr and up to 3.0 mtr. |
4 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .: |
5 | Ordinary rock |
6 | Hard rock (requiring blasting) |
7 | Add extra for trenches for every additional lift over item no 4.3 |
8 | Above 1.5 mtr and up to 3.0 mtr. |
9 | Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
10 | 100 mm |
11 | 150 mm |
12 | 200 mm |
13 | 250 mm |
14 | 300 mm |
15 | 350 mm |
16 | 400 mm |
17 | 450 mm |
18 | 500 mm |
19 | 600 mm |
20 | Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-9 gradeS&Spipesas per IS:8329-2000 (amendeduptodate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
21 | 200 mm |
22 | Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M. |
23 | HDPE PE-80PN-6 |
24 | 75 mm |
25 | 90 mm |
26 | 110 mm |
27 | Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M. |
28 | HDPE PE-80PN-6 |
29 | 125 mm |
30 | 140 mm |
31 | 160 mm |
32 | 180 mm |
33 | 200 mm |
34 | 225 mm |
35 | Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. |
36 | 100 mm pipe |
37 | 150 mm pipe |
38 | 200 mm pipe |
39 | 250 mm pipe |
40 | 300 mm pipe |
41 | 350 mm pipe |
42 | Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
43 | Manually Operated CI Sluice valve of Class PN-1.0 |
44 | 80 mm HW |
45 | 100 mm HW |
46 | 125 mm HW |
47 | 150 mm HW |
48 | 200 mm HW |
49 | 250 mm HW |
50 | 300 mm HW |
51 | 350 mm HW |
52 | 400 mm with Gear |
53 | 450 mm with Gear |
54 | 500mm with Gear |
55 | 600 mm with Gear |
56 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valveof approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedupto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1.HP Orifice-HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
57 | Class PN 1.0 |
58 | 50 mm |
59 | 80 mm |
60 | 100 mm |
61 | 150 mm |
62 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirfing to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
63 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 (Junction Valve) |
64 | 80 mm dia |
65 | 100 mm dia |
66 | 150 mm dia |
67 | 200 mm dia |
68 | 250 mm dia |
69 | 300 mm dia |
70 | 350 mm dia |
71 | 400 mm dia |
72 | 450 mm dia |
73 | 500 mm dia |
74 | 700 mm dia. With Gear |
75 | 800 mm dia. With Gear |
76 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 |
77 | 100 mm dia |
78 | 150 mm dia |
79 | 200 mm dia |
80 | 250 mm dia |
81 | 300 mm dia |
82 | 350 mm dia |
83 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
84 | Class PN 1.6, Manually Operated with Gear |
85 | 300 mm dia |
86 | 350 mm dia |
87 | 400 mm dia |
88 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions,Face to face dimensions as per IS 5312 (part -1):2004Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brasswith EPDM/NBR "O "ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel)Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
89 | Class PN 1.6 |
90 | 100 mm dia |
91 | 150 mm dia |
92 | 200 mm dia |
93 | 250 mm dia |
94 | 300 mm dia |
95 | 350 mm dia |
96 | Providing, lowering, laying, aligning, fixing inposition CI D/F short body pattern type butterfly valves having body, disc and end cover in graded cast irongenerally conforming to (IS13095/1991amendedupto date), synthetic rubber faced ring secured on disc by retaining ring with SS steel screw stub shaft of SS riding in teflon bearing including C.C. foundation/ structural steel support, material,labour,testingalongwith pipe line andcommissioning asperTechnical Specifications andasper direction of Engineer in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work |
97 | Manually Operated Butterfly Valve PN-1.0For Junction/ sectional Valves |
98 | 200 mm dia (With Gear Operated) |
99 | 300 mm dia (With Gear Operated) |
100 | 350 mm dia (With Gear Operated) |
101 | 400 mm dia (With Gear Operated) |
102 | 450 mm dia (With Gear Operated) |
103 | 500 mm dia (With Gear Operated) |
104 | 600 mm dia (With Gear Operated) |
105 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, combination Air Release Valve Kinetic type with single chamber housed Double orifice and have 3 functions, large Air exhaust, small Air venting and large air intake during vacuum of pipeline of approved makes of following pressure rating and dia and as per following specifications:Governing standard - AWWA C512 ,Body and bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865,Float & internal trim: AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBRDrilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside Fastners - CS/ Galvenised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, Big orifice size should be equal or larger than the inlet flange bore, for fully comply with AWWA C512.), Valve including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
106 | Class PN 1.6 |
107 | 50 mm dia |
108 | 80 mm dia |
109 | 100 mm dia |
110 | 150 mm dia |
111 | 200 mm dia |
112 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 |
113 | 80 mm dia. |
114 | 100 mm dia. |
115 | 125 mm dia. |
116 | 150 mm dia. |
117 | 200 mm dia. |
118 | 250 mm dia. |
119 | 300 mm dia. |
120 | 350 mm dia. |
121 | 400 mm dia. |
122 | 450 mm dia. |
123 | 500 mm dia. |
124 | 600 mm dia. |
125 | AIR VALVE PILLAR -Construction ofRCC Air valve pillar of following size including required earth work (PCC 1:4:8 )circular pillar of M-20 cement concreteof suitable size as per GAD including providing fixing of GI pipe with flang and required fitting for air valve complete as per specification and scope of work. ( Item based on PWD BSR Kota 2019) |
126 | Air valve piller25 mm |
127 | Air valve piller 50 mm |
128 | Air valve piller 80 mm |
129 | Air valve piller 100 mm |
130 | Air valve piller 150 mm |
131 | VALVE CHAMBER- Construction ofRCC Valve Chamberof following size including required earth work (PCC M-10, 10 CM th. ) RCC vertical wallsin M-20grade cement concreteof suitable size as per GAD including providing fixing ofReinforced Ferro cement Drain cover designed for class "AA" loading complete as per specification and scope of work. |
132 | Valve Chamber size0.90X1.20 Valve size up to 150 mm |
133 | Valve Chamber size1.50X1.20 Valve size up to 200mm to 300 mm |
134 | Valve Chamber size1.50X1.80 Valve size up to 350mm to 450 mm |
135 | Valve Chamber size1.80X2.10 Valve size up to 500mm to 600 mm |
136 | Valve Chamber size2.40X2.10 Valve size up to 700mm to 900 mm |
137 | VALVE CHAMBER- Construction ofRCC Valve Chamberof following size including required earth work (PCC M-10, 10 CM th. ) RCC vertical wallsin M-25grade cement concreteof suitable size as per GAD including providing fixing ofReinforced Ferro cement Drain cover designed for class "AA" loading complete as per specification and scope of work. |
138 | Valve Chamber size0.90X1.20 Valve size up to 150 mm |
139 | Construction of CC Road |
140 | Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. |
141 | Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. |
142 | Bituminous courses |
143 | Granular courses |
144 | Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. |
145 | Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shallbe made for trench width more than specified,complete work as per technical specification and scope of work. |
146 | M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
147 | Removing& Re-fixing of Precast concrete interlocking blocks by manual, stacking of serviciable & non serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block against damaged, including alllead and lift as per Technical specifications.(Interlocking blockmanufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) |
148 | 60 mm thick. |
149 | 80 mm thick. |
150 | 100 mm thick |
151 | Repair of Bituminous Roadusing GSB 15 cm thick, WBM 15 cm thick in two layers , 20 mm thick bitumin carpet and sand seal coat Complete as per specification and scope of work. ( based on Kota 2019 PWD BSR Road 2019 |
152 | Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. |
153 | M20 grade Nominal Mix |
154 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
155 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor Three level. |
156 | Hot rolled deformed bars (IS : 1139). |
157 | Thermo-mechanically Treated bars (Conforming of relevent IS code) |
158 | SITC of Bulk Flow Meter with removable mechanism class "B" confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete:Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
159 | BFM 80 mm |
160 | BFM100 mm |
161 | BFM125 mm |
162 | BFM 150 mm |
163 | BFM200 mm |
164 | BFM 250 mm |
165 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304,Electrode : SS AISI 316L /Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
166 | EFM 80 mm |
167 | EFM100 mm |
168 | EFM 125 mm |
169 | EFM 150 mm |
170 | EFM 200 mm |
171 | EFM 250 mm |
172 | EFM 300 mm |
173 | EFM 400 mm |
174 | EFM 450 mm |
175 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below: 1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm, 3. Stone masonary in CM: 1:6 section of foundation above PCC,600 mm (W ) x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm. 5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6. 6. Expansion joint shall be on every 30 mtr. 7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided. 8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done. |
176 | IPS at notara WTP |
177 | Digod-IPS |
178 | RajpuraCPS |
179 | KAPREN WTP |
180 | GENDOLI KHURD-IPS |
181 | LABAAN-CPS |
182 | KARWAR-CPS |
183 | SARSALA-CPS |
184 | BAJAR-CPS |
185 | KHATKAR-CPS |
186 | Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints. |
187 | IPS at notara WTP |
188 | Digod-IPS |
189 | RajpuraCPS |
190 | KAPREN WTP |
191 | GENDOLI KHURD-IPS |
192 | LABAAN-CPS |
193 | KARWAR-CPS |
194 | SARSALA-CPS |
195 | BAJAR-CPS |
196 | KHATKAR-CPS |
197 | Construction of Pump house of required size suitable for installation ofpumping sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement. |
198 | IPS at notara WTP |
199 | Digod-IPS |
200 | RajpuraCPS |
201 | KAPREN WTP |
202 | GENDOLI KHURD-IPS |
203 | LABAAN-CPS |
204 | KARWAR-CPS |
205 | SARSALA-CPS |
206 | BAJAR-CPS |
207 | KHATKAR-CPS |
208 | Construction and commissioning of RCC flat slab Over Head Service Reservoir of following capacity and staging including all material and labour charges as per the Scope of work and Technical Specification, consisting of the following main activities: - |
209 | a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall. e) Successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab. |
210 | j) Providing and fixing water level indicator (float type). k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm p) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
211 | Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 15 M |
212 | 50 KL capacity |
213 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 18 M(6% increase) |
214 | 50 KL capacity |
215 | 75 KL capacity |
216 | Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - |
217 | a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e)Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type). |
218 | k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
219 | Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 18 M |
220 | 100 KL capacity |
221 | 150KL capacity |
222 | 200KL capacity |
223 | 250KL capacity |
224 | 300KL capacity |
225 | 350KL capacity |
226 | Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 20 M |
227 | 100 KL capacity |
228 | 150KL capacity |
229 | 200KL capacity |
230 | 250KL capacity |
231 | 300KL capacity |
232 | Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 22 M |
233 | 150 KL capacity |
234 | 250 KL capacity |
235 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 18 M |
236 | 100 KL capacity |
237 | 150KL capacity |
238 | 200KL capacity |
239 | 250KL capacity |
240 | 300KL capacity |
241 | 350KL capacity |
242 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 20 M |
243 | 150KL capacity |
244 | 300KL capacity |
245 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 22 M |
246 | 150KL capacity |
247 | 200KL capacity |
248 | 250KL capacity |
249 | 400KL capacity |
250 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 24 M |
251 | 200KL capacity |
252 | 250KL capacity |
253 | 300KL capacity |
254 | Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: - |
255 | a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. |
256 | h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
257 | Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 |
258 | 25 KL Capacity-1 Nos |
259 | 80 KL Capacity -1 Nos |
260 | 200KL capacity |
261 | 20 KL Capacity -1 Nos |
262 | 30 KL Capacity -1 Nos |
263 | 40 KL Capacity -1 Nos |
264 | 50 KL Capacity -1 Nos |
265 | 150 KL Capacity -1 Nos |
266 | 70 KL Capacity -5 Nos |
267 | 200 KL Capacity -1 Nos |
268 | Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: - |
269 | a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. . b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. |
270 | h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k)Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
271 | Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3. |
272 | 700 KL capacity |
273 | 1200 KL capacity |
274 | Construction of RCC (Flat slab type) Rectangular Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase in side and out side. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. |
275 | d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab.j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m)Construction of inlet chamber, and valve chambers n) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
276 | 3500 KL |
277 | 2500 KL |
278 | 1500 KL |
279 | 1900 KL |
280 | 2500 KL |
281 | 2700 KL |
282 | 2800 KL |
283 | Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications:Body-Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030,Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 420/ Gr 1.4021Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2.Insersion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied bothinside and outside . Suitablesupport structure as per directions of EIC including jointing & jointing material,labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge.Note: Rates are exclusive of tail piece/ dismantling joints and |
284 | Plunger Type Flow Control Valve |
285 | 200mm dia |
286 | 300mm dia |
287 | 400 mm dia |
288 | 500 mm dia |
289 | Providing,installation, testing and commisioning of vacuum Feed Gas Chlorinator with all assessories and making connection with existing pipeline required including supply & instalation of trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragm Valve on injector inlet & outlet, 32 OD uPVC pipe for chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GM gate valve on pump suction & delivery, 25 NB GM "Y" type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressure gauge with Isolated valve on pump delivery and chlorine booster pump with motor of required capacity complete in all respect as per specification and the direction of the Engineer |
290 | 1 kg/hr capacity |
291 | 2 kg/hr capacity |
292 | 3 kg/hr capacity |
293 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ. |
294 | Discharge 141 to 160 LPS and head 41 to 50 M |
295 | Discharge 101 to 120 LPS and head 61 to 70 M |
296 | Discharge 121 to 140 LPS and head 31 to 40 M |
297 | Discharge 181 to 200 LPS and head 41 to 50 M |
298 | Discharge 61 to 70 LPS and head 51 to 60 M |
299 | Discharge 71 to 80 LPS and head 71 to 80 M |
300 | Discharge 20 to 30 LPS and head 81 to 90 M |
301 | Discharge 20 to 30 LPS and head 71 to 80 M |
302 | Discharge 41 to 50 LPS and head 81 to 90 M |
303 | Discharge 31 t0 40 LPS and head 51 to 60 M |
304 | Discharge 81 to 90 LPS and head 31 to 40 M |
305 | Discharge 161 to 180 LPS and head 51 to 60 M |
306 | Discharge 20 to 30 LPS and head 51 to 60 M |
307 | Discharge 31 t0 40 LPS and head 61 to 70 M |
308 | Discharge 101 to 120 LPS and head 51 to 60 M |
309 | Discharge 41 t0 50 LPS and head 61 to 70 M |
310 | Discharge 31 t0 40 LPS and head 61 to 70 M |
311 | Discharge 20 to 30 LPS and head 71 to 80 M |
312 | Discharge 20 to 30 LPS and head 61 to 70 M |
313 | Discharge 41 t0 50 LPS and head 51 to 60 M |
314 | Discharge 20 to 30 LPS and head 41 to 50 M |
315 | Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
316 | Centrifugal Monoblock Pump set (Single Stage) |
317 | 9.3 KW (12.5 HP) |
318 | 11.0 KW (15 HP) |
319 | Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel)as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. |
320 | 100 mm dia. |
321 | 150 mm dia. |
322 | 200 mm dia. |
323 | 250 mm dia. |
324 | 300 mm dia. |
325 | 600 mm dia |
326 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
327 | Dia of Pipe: 300.00 mm (I.D) |
328 | Thickness of Pipe |
329 | 5.0 mm |
330 | 300 mm dia (5mm Thick) |
331 | Dia of Pipe: 400.00 mm (I.D) |
332 | Thickness of Pipe |
333 | 5.0 mm |
334 | Dia of Pipe: 500.00 mm (I.D) |
335 | Thickness of Pipe |
336 | 5.0 mm |
337 | Dia of Pipe: 600.00 mm (I.D) |
338 | Thickness of Pipe |
339 | 5.0 mm |
340 | Dia of Pipe: 900.00 mm (I.D) |
341 | Thickness of Pipe |
342 | 5.0 mm |
343 | Dia of Pipe: 700.00 mm (I.D) |
344 | Thickness of Pipe |
345 | 5.0 mm |
346 | Dia of Pipe: 800.00 mm (I.D) |
347 | Thickness of Pipe |
348 | 5.0 mm |
349 | Dia of Pipe: 550.00 mm (I.D) |
350 | Thickness of Pipe |
351 | 5.0 mm |
352 | 600 mm dia (7mm thick) |
353 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes |
354 | 150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) |
355 | 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) |
356 | 250 mm dia NB (Thickness of pipe 7.1 mm & mass of tube 46.57 Kg/m) |
357 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge. |
358 | MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) |
359 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proofKinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammended up to date) Body, High pressure cover , Low pressure cover, Cowl andJoint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will have a screen to prevent Tamper of float,with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amendedupto date) PN 1.6 ratings Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
360 | Class PN 1.6 |
361 | 40 mm |
362 | 50 mm |
363 | 80 mm |
364 | 100 mm dia |
365 | 200 mm dia |
366 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete inI/rail section upto intake height.for hoisting and fixing for every additional one metre or part thereof beyond 10 mtr height. |
367 | Providing and fixing double flanged ISI markedGI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. |
368 | 50 mm |
369 | 65 mm |
370 | 80 mm |
371 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
372 | 2.2 KW (3.0 HP) |
373 | Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. |
374 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air ValveFlanged/ Screwed type of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedupto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1,Body seat ring - Leaded tin bronze/ SS , Seal ring and face ring - EPDM/NBR, Ends flanged according to IS 6418 or screwed Screwed type shall have extcrnal pipe threads conforming to IS 554Fastners - CS Epoxy paint inside outside of food grade safe for drinking water ,Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
375 | Class PN 1.0 |
376 | 25 mm S-1 Type |
377 | VTC - Construction ofvillage lavel transfer chamber and meter room, work including require earth work PCC 1:3:6 under floor & for foundation, walls of chmber constrected by RCC M-20, with Fiber reinforced Ferro cement drain cover (light duty). Construction of brick masonary meter room above GL,23 cm thick Brick masonary walls over stone masonary foundation coverd by RCC roof, CC flooring, MS sheet door,GI pipe etc. with locking arrangments |
378 | Providing Household Tap Connectionas per technical specification and approved drawing as per relevant IS code (amended up to date) from uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PVC/MS saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil (excluding road); depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including MS/PVC saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valveand specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipe with fittings in the premises for fixing a tap / meter box (excluding),including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid seperately. |
379 | For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. |
380 | Providing Household Tap Connectionas per technical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid seperately. |
381 | For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. |
382 | P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore. |
383 | Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. |
384 | Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. |
385 | Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification. |
386 | 300 mm Dia 8 mm thick casing pipe. |
387 | 500 mm Dia 8 mm thick casing pipe . |
388 | 600 mm Dia 10 mm thick casing pipe . |
389 | 700 mm Dia 10 mm thick casing pipe . |
390 | Providing and applying 100% Solids,Rigid, DTM Polyurethane Coating to internal surface of M.S. Pipe as per AWWA C222 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Polyurethane Coating shall be NSF/WARS/SS-375 approved for drinking water. |
391 | Providing and applying following Coating to the External surface of MS pipes, including preparation of surface by cleaning as per ISO 8502-3/ SSPC-SP10/ NACE No.2 near white blast cleaning and abrasive blasting to a finish to SA 2.5 as per ISO: 8501-1 and surface profile / anchor profile of 50-75 / 75-100 microns as per ISO: 8503-2, including field joint coating at site complete as per Technical specifications and direction of Engineer –in-charge: 3 LPE (3 Layer Polyethylene) / DFBE (Dual Layer Fusion Bonded Epoxy)/ PU (Polyurethane)/ Polyolefin Tape coating . |
392 | Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centering, shuttering and reinforcement including curing, compaction, finishing with rendering in cement sand mortar 1 : 3 (1 cement : 3 coarse sand) and making good the joints and Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete improve workability without impairing strength and durability as per direction of Engineer-in-charge. M-25 grade reinforced cement concrete. All wiork up to plinth level. |
393 | Providing M-25 grade concrete |
394 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
395 | Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like with pumping set of following H.P. including P.O.L. complete. |
396 | 10 to 19 H.P. |
397 | Banking excavated earth in layers not exceeding 20cm. in depth breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers, and rolling every 3rd and top- most layer with power roller of 8-10 tonne capacity and dressing up in embankments for roads, flood banks marginal banks, and guide banks etc. lead up to 50 Mtr. and lift up to 1.5 Mtr. All kinds of soils |
398 | Carrage of Earth, Sand, Lime, Morrum manure or sludge Leadupto2 KM for Earth |
399 | SITC of IEC, TUV certified, MNRE approved Solar Panels suitable for Rooftop as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and structure, showing arrangement of panel on available space, installation ofPV module structure on shed / roof as per drawings including super structure wherever necessary as per drawin. Mountingstructure suitably designto withstand wind velocity upto 150km/hr. Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5years warranty. All cabling up to panel and metre, earthing etc. required accessiories and taxes are inclusive. Note: There shall be 5 year service warranty for solar panel and mounting structureandsuitable provision shall be included in tender document. |
400 | For Pumping Stations |
401 | Digod IPS |
402 | Rajpura CPS |
403 | PEEPALDA KALAN-CPS |
404 | BANGROD CPS |
405 | RAMPURIYA CPS |
406 | For 2 HP Pumps (1.92*2) |
407 | GENDOLI KHURD-IPS |
408 | LABAAN-CPS |
409 | KARWAR-CPS |
410 | SARSALA-CPS |
411 | BAJAR-CPS |
412 | KHATKAR-CPS |
413 | For 1 HP Pumps (0.96*3) |
414 | For 2 HP Pumps (1.92*4) |
415 | For 3 HP Pumps (2.88*1) |
416 | For 5 HP Pumps (4.88*3) |
417 | Providing, installation, testing and commissioning of AC submerssible pump sets with inbuilt or individual solar pump controllerwith Maximum power point tracking (MPPT) for optimally use the solar panel and maximize water discharge to deliver maximum water during the day including PVC flat submersible cable from controller to motor pumps.. Solar pumpshall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope . Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit, accidental short circuit and reverse polarity should be provided. A good reliable on/off switchbe provided. The cable shall be ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date. The duty condition of pump set shall be as per scope of work and entire work shall be executed as per technical specification and direction of Engineer in charge. |
418 | 1.5 KW (2.0 HP) (3+3) |
419 | 0.75 KW (1.0 HP) (3+3) |
420 | 1.5 KW (2.0 HP) (4+4) |
421 | 2.2 KW (3.0 HP) (1+1) |
422 | 3.7 KW (5.0 HP) (3+3) |
423 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. |
424 | 50 mm dia |
425 | 65 mm dia |
426 | 80mm dia |
427 | Providing, lowering, aligning, fixing in position in pipe line, CIdouble flangedDual plate check valave of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications:Body & Cover of Grey cast iron ofIS:210/ FG200 , Disc / plates - Cast steel ,Disc seal ring of EPDM/ NBR (food grade quality) ,Body seat of SS ,Face to face dimensions as per API: 594 ,Flanges Drilled as per IS:1538.Epoxy (Non-Toxic & suitable for drinking water) applied on body & coverinside and outside . Shaft/Stop Pin of SS- AISI- 304/410 , Hinge SS AISI 316/304 / CS ,SpringSS AISI 316/304 , Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal.Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.as per API: 594 and flanges as per ISS of approved makeof following Class and dia complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
428 | Class PN 1.0 |
429 | 80 mm dia |
430 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. "B" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
431 | Pressure gauge-1 to 1.0 kg/sq.cm with isolation vave |
432 | Providing, installation, testing and commissioning of glycerin filledPressure gauge of following ranges with isolation valve and tap offpipe complete in all respect as per technical specification and as perdirection of Engineer. |
433 | 0 to 4.0 / 0 to 6.0 / 0 to 10.0 kg/cm² |
434 | Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement. |
435 | (I) For Solar/Electrical driven pump sets - 2.5 M X 2.5 M (12Nos.) |
436 | (I) For Solar/Electrical driven pump sets - 2.5 M X 2.5 M (1 Nos.) |
437 | Provision of J2 Types Quarter |
438 | provision of store cum office |
439 | Provision of Inspection bungalow |
440 | Provision of Meeting Hall |
441 | Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 meter.All kinds of soil. |
442 | Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering =All up to plinth leve |
443 | 1:4:8 (1Cement :4 Course Sand :8 Graded stone aggregate 40 mm nominal size |
444 | Flyash Brick work with flyash Bricks of class designation 75 in superstructure above plinth level upto floor Three Level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
445 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix : 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size) |
446 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor Three level for : |
447 | Walls (any thickness) including attached pilasters, buttresses plinth and string course. |
448 | Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping, bed plates, anchor blocks, sills, chhajjas lintel, beam etc. |
449 | Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
450 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. |
451 | Thermo Mechanically treated bars |
452 | Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
453 | Plaster on new surface on walls in cement sand mortar 1:3 including raking of joints etc. complete fine finish: |
454 | 25 mm thick. |
455 | Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with "code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping. |
456 | 250 mm nominal bore |
457 | Supply & lowering air line of 25mm dia, G.I. pipe "B" class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. |
458 | Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. |
459 | Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids |
460 | Size 9 to 12 mm |
461 | Size 3 to 5 mm |
462 | Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. |
463 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. |
464 | 110 mm dia |
465 | 160 mm dia |
466 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: |
467 | Cuppler |
468 | 110 mm dia |
469 | 160 mm dia |
470 | Tee |
471 | 110 mm dia |
472 | 160 mm dia |
473 | Bend 87.5 |
474 | 110 mm dia |
475 | 160 mm dia |
476 | Pipe Clip |
477 | 110 mm dia |
478 | Extra for supplying and fixing of 560 mm dia Ductile Iron manhole frame & cover, Hinged Type, Heavy Duty with test load of 400 KN, class D-400 as per BS EN 124, in place of RCC/ SFRC manhole frame & cover (ED/EHD) in manhole. |
479 | Providing and fixing of reinforced Ferro-Cement drain covers designed for "AA" class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc. Standard Size 2100x500mm (150mm thick) for span 1201 to 1500mm |
480 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor Three level. Thermo-mechanically Treated bars (Conforming of relevent IS code) |
481 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI –92 num DO – 92 num AI –16 num AO – 8 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 30 num Selector Switch - 15 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer – 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 30 num Wiring + TB etc – 1 lot Hardware – 1 lot |
482 | HIM Display, Colour, 12" having Ethernet Port, USB Port ect. |
483 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 800 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithOperator Station(PC)including,necessaryprogramming softwareforPLC&SCADAandcomprisingofall required accessories not limited to the following: ProgrammableLogicController(PLC)withDual redundantCPU,PowersupplymoduleforIO& Processorrack(StandardDC),Backup Interface/ExpansionModule(BCM/BEM),Rack (Backplane) 10 slots for IO and Processor – 1 lot DI – 288 num DO – 176 num AI – 32 num AO – 16 num Ethernet Switch – 3 num , MCB 10A DP – 1 num MCB4ADP – 2 num , MCBSP2A – 10 num , MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num , Push Buttons – 30 num Selector Switch – 15 num , Control Relays – 150 num Annunciatorwith24WindowsNOtoNCType , MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter , Control Transformer – 1 num Emergency PB – 1 num , Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 30 num Wiring + TB etc – 1 lot Hardware – 1 lot HMI – 2 num OperatorStationincluding,Corei5processor,8GB DDR-3RAM,500GBHDD,DVDRWDrive,RS-232/485Ports,1ParallelPort,4nos.USBPort,2x EthernetCards,Keyboard,opticalmouse,32""monitor, Latest windows professional ver., etc. – 02 num ProgrammingandtroubleshootingsoftwareforHMI– OWS – 1 lot Colour Printer A4, Lasejet – 1 num |
484 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
485 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
486 | 3KVA |
487 | 2KVA |
488 | 5KVA |
489 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 800 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithOperator Station(PC)including,necessaryprogramming softwareforPLC&SCADAandcomprisingofall required accessories not limited to the following: ProgrammableLogicController(PLC)withDual redundantCPU,PowersupplymoduleforIO& Processorrack(StandardDC),Backup Interface/ExpansionModule(BCM/BEM),Rack (Backplane) 10 slots for IO and Processor – 1 lot DI – 288 num DO – 176 num AI – 32 num AO – 16 num Ethernet Switch – 3 num MCB 10A DP – 1 num , MCB4ADP – 2 num MCBSP2A – 10 num , MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num , Push Buttons – 30 num Selector Switch – 15 num , Control Relays – 150 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter , Control Transformer – 1 num Emergency PB – 1 num , Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num , Control Indication Lamp – 30 num Wiring + TB etc – 1 lot Hardware – 1 lot HMI – 2 num OperatorStationincluding,Corei5processor,8GB DDR-3RAM,500GBHDD,DVDRWDrive,RS-232/485Ports,1ParallelPort,4nos.USBPort,2x EthernetCards,Keyboard,opticalmouse,32""monitor, Latest windows professional ver., etc. – 02 num ProgrammingandtroubleshootingsoftwareforHMI– OWS – 1 lot Colour Printer A4, Lasejet – 1 num |
490 | CentralDataLogger-PCbasedDataAcquisitionSystemwithXR PremiumLicenseSoftwaresuitableforStoring,Logging,Reporting, Printingdata,Validationandcommunicatingwithabove offeredLocalDAS.PCwithspecificationsasunder:PentiumDual Core 2 Processor, 2 GB RAM, 250GBHDD, CD/DVD Combo Drive, 19"TFTMonitor,2serial&1parallelports,Standard WINDOWSOperatingSystem,standardkeyboard,mousewithpad and Color Laser printer. |
491 | Optic Fibre Cable, Armoud, Single Mode , 6 Core, Industrial Application, |
492 | TP-Link Gigabit SFP to RJ45 Fiber Media Converter, Fiber to Ethernet Converter -10/100/1000Mbps RJ45 Port to 1000Base-LX Single-Mode Fiber. One RJ - 45 and two Fiber port (SC type connector), Auto MDI support, AC 240V or DC +5V, Store and Forward Mode, 10Km 1000 Base-T to 1000 Base-LX. |
493 | Supply, Installation, Testing Commissioning of SERVER type: 2U rack server with configuration flexibility;Processor(s): TwoDual Core 64-bit Intel CPUs, 2.4 GHz;Memory: 8 GB RAM;Local Storage: Two hard drives, 1TB each, RAID 1 mirrored;SCSI Controller: Ultra 320 on board and PCI Ultra 320;Operating System: Windows Server 2012, Enterprise Edition or higher;Network adapter: Dual Embedded Gigabit Ethernet NIC & PCI NIC Power Supply: Redundant 750Watt hot-plug power supply; andKeyboard/monitor: Keyboard and monitor inside the rack. Make - HP/DELL/ LENOVA |
494 | SITCof55""FlatScreenHDLEDTVwithremotecontrolandwall mountunit/floorstandcompletewithmakingconnectionsetc.as required Sony/ Samsung/Panasonic) |
495 | SITCofIntelligentEthernetSwitchesproviding24x10/100Fast Ethernetports-and2dualpurposeuplink(provisionforCopper/ FiberGigaconnectivity)with LAN based Software.TheLANbased S/Wsupportsenhancedintegratedsecurity,includingNetwork AdmissionControl(NAC),advancedqualityofservice(QoS), availabilityandscalablemanagementtoenablenewcoverged applications |
496 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelarmouredoverallPVCsheathed(ST-1) overallscreenedCorearmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
497 | 1 SQMM, 24 Core |
498 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
499 | 1 SQMM, 1 Pair |
500 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
501 | 4C x 2.5 sq.mm |
502 | 4C x 1.5 sq.mm |
503 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
504 | 0-5M |
505 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2"NPT(M)/Accuracy:0.15%Protection: IP67 |
506 | 1/2" M (NPT) |
507 | Providing,installation,testingandcommissioningofDiaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass,Overrangeprotection:125%ofmaximumpressure,Material ofsensorandotherwettedparts:SStype316,Housingmaterial: Die cast aluminum |
508 | Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material ofsensorandotherwettedparts:SStype316,Housing:Diecast aluminum,Switchtype:Microswitch,Repeatability:±1%ofspan, Switch Contacts: 2 NO + 2 NC |
509 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
510 | Providing,Installation,TestingandCommissioningofpH ANALYSER for WaterApplication :Transmitter : Range:0-14pH, PowerSupply230VAC,Input:OneDigitalSensor,Output:4-20mAHART,IP66Protection/Txprotectioncoverrequired/ SensorRange0-14pH,abletotransmitdigitalsignalto transmitter,calibrationdatacanbetransferredtoTransmitter, process temp: 65 deg cen/ flow through teeMOC SS |
511 | 0-14 pH |
512 | Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l |
513 | 0.05 -20 mg/l |
514 | Providing,Installation,TestingandCommissioningofTURBIDITY ANALYSER for WaterApplication : Turbidity Measuring range: 0 to 100NTU;Accuracy:+/-2%ofreadingor+/-0.02NTU;Compliance toUSEPA180.1,Withinbuilttransmitterwith4-20mAoutput, Relay contacts & Modbus communication |
515 | 0 - 100 NTU |
516 | PRE-WIRED RTU Panel Compact RTU for variable power supply using batteries, rechargeable batteries, solar or 10.8 V DC to 28.8 V DC with integrated UMTS modem; connection to control center via Tele Control Basic, DNP3, IEC60870-5-104 and SINAUT ST 7 protocols, on-board I/O (8 DI, 4 DQ, 4 AI), configuration and diagnostics per web interface, RJ45 port, mobile communications antenna (GSM/UMTS), Mini SIM card, with adapter Micro SIM card also, GPRS (Multi-slot Class 10), 35 mm DIN rail mounting, TCP/IP, DNP 3, Open VPN-Client. |
517 | Programming and Troubleshooting software for RTUs |
518 | Supply, installation, testing and commissioning ofMNRE approved off GridSolar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS fabricated structure 120 micron hot dip galvanized iron , showing arrangement of panel in available space and installation ofPV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in RCC. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structureandsuitable provision shall be included in tender document. |
519 | Earthing Schedule Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. "B" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
520 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.25mm x 3mm GI strip |
521 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. (1 Pair * 0.75SQMM) |
522 | Supply of GSM /GPRSbased data transmitter water meter (woltman pulse output ) Model -AE 09-B SIM 2G Battery power -7.4V battery life 3 yr (data once a day) Input Pulse , 4-20ma From pressure RS485 Display-16*2 LCD Encloser-165*120*65 mm ABS Protection-IP65 Operating tempreature -055 C |
523 | Supply,Installation,Testingandcommissioningofcopperwound Transformers33/0.433KV,ThreePhase,50Hz,DYN11,ONAN type , Standard accessories with off load tap changer(+5% to -10% instepsof2.5%),winding/Top---temperatureriseof45°C/40°C firstfilloil,havingpermissibletotallossvaluesnotexceeding7.5% of the maximum total loss values for 11 KV as per energy efficiency level- 2atbasicInsulation levelconferming to ISS2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014. Transformersdescribedasaboveandasperthefollowing continuous rating |
524 | 630 KVA |
525 | 750 KVA |
526 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
527 | 200KVA |
528 | 250KVA |
529 | 315KVA |
530 | 160KVA |
531 | 400 KVA |
532 | SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star. |
533 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV Fixed type VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with ABB make Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. |
534 | Supply,Installation,TestingandCommissiongofindoortypefloor mountedmetalclad,33KVIncomerVCBpanelupto630A equippedwithfollowingswitchgearsandaccessoriesdesigned& testedasperlateststandardi.e.IEC62271-200,suitableforSTC 31.5KA/3andIACA-FLRfor31.5kA/1sec.MakeofHTPanel, Vaccum Interrupter and VCB should be of same make. 33KV/110VoltsPTClass0.5accuracyand100VAburdenwith1No. Voltmeter (0-36 KV), analog type, selector switch for voltmeter andprotectionfuses/MCBforHTmeteringupto36KVonincomer, Ammeter,analogtype,selectorswitchesforammeters, MicroprocessorbasednumericalrelaywithO/L,E/FandS/C protection,Setofdualcoredualratio3CTsofsuitableratiowith secondary1A,15 VAburden and accuracy Class – 0.5 for metering and class 5P10 for protection, Multifunction Meter. |
535 | Supply,Installation,TestingandCommissiongofindoortypefloor mountedmetalclad,33KVBusCouplerVCBpanelupto630A equippedwithfollowingswitchgearsandaccessoriesdesigned& testedasperlateststandardi.e.IEC62271-200,suitableforSTC 31.5KA/3 and Internal Arc test A-FLR for full short circuit current for 1sec.duration.MakeofHTPanel,VaccumIntrrupterandVCB should be of same Make. Bus Coupler 1 No 630 Amp. VCB |
536 | Supply,Installation,TestingandCommissiongofindoortypefloor mountedmetalclad,33KVoutgoingVCBpanelupto630A equippedwithfollowingswitchgearsandaccessoriesdesigned& testedasperlateststandardi.e.IEC62271-200,suitableforSTC 31.5KA/3andIACA-FLRfor31.5kA/1sec.MakeofHTPanel, Vaccum Interrupter and VCB should be of same make. 3KV/110VoltsPTClass0.5accuracyand100VAburdenwith1No. Voltmeter (0-36 KV), analog type, selector switch for voltmeter andprotectionfuses/MCBforHTmeteringupto36KV,Ammeter, analog type, selector switches forammeters, Microprocessor based numericalrelaywithO/L,E/FandS/Cprotection,Setofdualcore dualratio3CTsofsuitablerationwithsec1of15VAburdenand accuracyClass–0.5formeteringandclass5P10forprotection, Multifunction Meter |
537 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
538 | 110VDC |
539 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%,50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlasrequired of following rating: |
540 | 25 A + 25 A |
541 | Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. "B" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
542 | Earthing Schedule Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. "B" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
543 | GI Pipe, Class B, 40mm Dai with thickness of 3.610mm as per IS 1239 for the complete earthing system |
544 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
545 | 50mm x 6mm copper strip |
546 | 50mm x 6mm G.I. Strip |
547 | 32mm x6mm G.I. Strip |
548 | 25mm x 6mm G.I. Strip |
549 | Providing&LayingXLPEinsulatedIS:7098/II/85of approved make H.T.cable for working voltage 33 K.V.Un EarthedwithStrandedCompactedCircularAluminium Conductor,ConductorScreenedwithExtrudedSemi-conductingcompound,XLPEInsulated,Insulation Screenedwithextrudedsemi-conductingcompoundin combinationwithCopperTape,coreslaidup,inner sheathofThermoplastictape,galvanisedflatsteelstrip armouredandoverallExtrudedPVCTypeST-2Outer Sheathedcable direct in ground including excavation of 30cmx150cmsizetrench,25cmlayerofriversand, second Class bricks covering, refilling earth, compaction ofearth,makingnecessaryconnectiontestingetc.as required of size. |
550 | 3 core 240.0 Sq.mm |
551 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPE insulated33KVcable,withrequiredcomponents,preprationof cable ends, testing etc. as required of following sizes. |
552 | Indoor |
553 | 3 core 240/300 /400 Sq.mm |
554 | Outdoor |
555 | 3 core 240/300 /400 Sq.mm |
556 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
557 | 400 SQMM,3.5 core |
558 | 300 SQMM,3.5 core |
559 | 240 SQMM,3.5 core |
560 | 25 SQMM, 3 CORE |
561 | 95 SQMM, 3 CORE |
562 | 150 SQMM, 3 CORE |
563 | 35 SQMM, 3 CORE |
564 | 50 SQMM, 3 CORE |
565 | 10 SQMM, 3 CORE |
566 | 16 SQMM, 3 CORE |
567 | 185 SQMM, 3 CORE |
568 | 150 SQMM,3.5 core |
569 | 70 SQMM, 3 CORE |
570 | 120 SQMM, 3 CORE |
571 | 4.0 Sq.mm x 3 Core |
572 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
573 | Hot Dipped Galvanized |
574 | 450mm x 50mm x 2.0mm |
575 | 600mm x 50mm x 2.0mm |
576 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
577 | Hot Dipped Galvanized |
578 | 100mm x 50mm x 1.6mm |
579 | 150mm x 50mm x 1.6mm |
580 | 300mm x 50mm x 1.6mm |
581 | 450mm x 50mm x 2.0mm |
582 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR as per latest IS 1562 :2006., 33 KV, 3 mm thick with proof voltage 36 KV / 3 min. and Break Down Voltage 65 KV |
583 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalcompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
584 | Incommerfeeder(drowouttype)fortransformer630A/800A,50KA, ACB3pole,AlBusBars,DigitalMultifunctionmetercompatableto SCADA,metering,ProtectionCT"s,IDMT3-O/C&1-E/F,indicating lamps,controlfuse,wiringetc.completeinallrespectofthesize appxo 900(D)X.2400(H)X1000(D) |
585 | Incommer feeder for (drowout type ) transformer 1000A, 50KA, ACB 3pole,AlBusBars,DigitalMultifunctionmetercompatableto SCADA,metering,ProtectionCT"s,IDMT3-O/C&1-E/F,indicating lamps,controlfuse,wiringetc.completeinallrespectofthesize appxo 900(D)X.2400(H)X1000(D) |
586 | Incommerfeederfor(drowouttype)transformer1250A,50KA, ACB3pole,AlBusBars,DigitalMultifunctionmetercompatableto SCADA,metering,ProtectionCT"s,IDMT3-O/C&1-E/F,indicating lamps,controlfuse,wiringetc.completeinallrespectofthesize appxo 900(D)X.2400(H)X1000(D) |
587 | BusCouplerFeeder(drowouttype),1250AACB,50KA,3Pole withoutreleasewithAlBusBars,IndicatingLamps,ControlFusesandwiringetc.completeinallrespect.Size:900(W)x2400(H)x 1000 (D) |
588 | Bus Coupler Feeder (drowout type ), 630/800 A ACB, 50KA, 3 Pole withoutreleasewithAlBusBars,IndicatingLamps,ControlFuses andwiringetc.completeinallrespect.Size:900(W)x2400(H)x 1000 (D) |
589 | BusCouplerFeeder(drowouttype),1000AACB,50KA,3Pole withoutreleasewithAlBusBars,IndicatingLamps,ControlFuses andwiringetc.completeinallrespect.Size:900(W)x2400(H)x 1000 (D) |
590 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
591 | 400 A MCCB Incomer (Fixed type )with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
592 | 630AMCCB(Fixedtype)asoutgoingCT"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)X900(H)X1000(D) |
593 | 250AMCCB(Fixedtype)asoutgoingCT"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)600(H)X1000(D) |
594 | MCCB up to 100A(Fixed type ) as outgoing CT"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
595 | 400AMCCB(Fixedtype)asoutgoingCT"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)X900(H)X1000(D) |
596 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
597 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
598 | 22KW |
599 | 30KW |
600 | 37KW |
601 | 45KW |
602 | 55KW |
603 | 75KW |
604 | 90KW |
605 | 125KW |
606 | 433V APFC Panel( 250KVAR) in cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
607 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
608 | Local Push Button Station |
609 | SupplyanderectionofOctagonalpoleoffollowing lengthand dimensionas per table-3 withbaseplateon thecementconcretefoundationofM-15/M-20grade (1:1.5:3)withthehelpofanchorboltsofgrade6.8(IS 1367PIII).ThepoleshallbemadeofS-355JOgrade steelsheet,foldedlengthwisetoobtainedOctagonal shape,havingsinglelongitudinalseamweldandhot dippedgalvanisedinternally&externallyinaccordance withIS2629.Thepoleshallhaveaweatherproofflush doorandlockingarrangements.Thecompletework shallbesupervisedandcertifiedbythemanufacturers forsatisfactorysupply,erection,testingand commissioning. |
610 | 7 Mtr. |
611 | Supply,ErectionandFixingofhotdippedgalvanised Overhang (60 X 3.25 mm) with cap (250 x 137.9 x 4.05 mm) over the poles |
612 | Single arm overhang |
613 | P/FIP-65/IP-66protectedstreetlightluminarieson bracket / Arm.Fixturemadefrompowdercoated singlepiecepressurediecastaluminumhousingwith heat dissipation fins on housing with high power LEDs . Diffuser/glasscoverforensuringIP-65protectionfor lampandcontrolgearcompartment,systemlumen outputof100lum/watthighpowerLED.Integrated drivershallbehighefficiencyhavingefficiencymore than 85 % and in compliance to IEC standards. System lifeof50000burninghourswith70%ofinitiallumens maintained. Fixture shall be in CE compliance. IP-65 protected LED street light luminaries |
614 | LED street light fixture 80-90 watt |
615 | P&FIP-65protectedintegralfloodlightluminaire suitableforHPSV/Metalhalidelampcomprisingof powdercoateddiecastaluminiumhousing, electrochemicallybrightenedandanodizedstippled aluminium reflector, covered with suitably gasketed heat resistant and toughened glass, porcelain holder, integral controlgearboxhavingcopperballast,capacitor, electronicignitorprewiredwithpvcinsulatedcopper conductoruptoterminalblockincludingmaking connection testing etc. |
616 | 1 X 250 Watt |
617 | P&FHighpressuresodiumvapour/Highpressure mercuryvapour/Metalhalide/Halogenlampas required. HPSV tubular lamp normal output. |
618 | 250 Watt |
619 | Supply, erection testing and commissioning of high mast lightingsystem(asperCP3-TRT/1996ofILE,UK) consistingoftotallyhotdipgalvanisedbysingledipped method high mast, lantern carriage suitable for up to 12 nosluminaries,mastheadassembly,twonosaviation obstruction neon lights, double drum type self sustaining winch,integralpowertool(winchmotorwithcontrol circuit) hot dipped galvanised heavy duty pipe lightening finial,suitableropesandCCfoundationofM-15grade complete as required. The mast is constructed from mild steelplates(asperBS-EN10025)cutandfoldedto form a polygonal section, telescopic jointed and welding as per BS 5135. The complete work shall be supervised andcertifiedbythemanufacturersforsatisfactory supply,erection,testingandcommissioningofhigh mast.withallaccessories,whichalsoincludsinternal electricalcableandpanelwithfoundation. |
620 | 20 Mtr Hm (in 2 section) |
621 | P&FIP-65protectedmultitapballaststreetlight luminaireon bracketsuitableforHPSVLAMP, madeoutfrompowdercoatedsinglepiecediecast aluminiumhousing,electrochemicallybrightenedand anodized POToptics aluminium reflector, heat resistant andtoughenedglasscoverandaccessorieslikemulti tapcopperballast,electronicignitor,capacitor,holder prewireduptoterminalblocketc.asrequiredincluding makingconnectiontestingetc. |
622 | 1 X 250/ 150 Watt |
623 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
624 | Supply , Installation, Testing and Comissioning of 11 KV, 630 A, 20kA / 3 sec, Out door, Extensible type Ring main unit (RMU) in suitable RCC foundation with 2 no. Load break switch & 1 no. VCB / SF6 circuit breaker with over load, Earth fault, short circuit relay, copper bus bar, earthing switch, mechanical ON / OFF / Earth indication, Voltage presence indicator, Ring core protection CT 2.5 VA, 10P10 as per transformer rating, Shunt trip coil, Anti reflex operating handle, right angle boots etc. OEM Must have BIS certificate and & shall have submitNABL / CPRI / ERDAlab typetest reportsbefore executionas required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . |
625 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conducting compoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
626 | 3 core 120.0 Sq.mm |
627 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
628 | Indoor |
629 | 3 core 120/150/185 Sq.mm |
630 | Outdoor |
631 | 3 core 120/150/185/225 Sq.mm |
632 | S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ControlMCBwithpanelwithallaccessorieswithfollowing rating |
633 | 9.3KW |
634 | 11KW |
635 | 15KW |
636 | 18.5KW |
637 | Supply, receving, storing,inspection, handling , assembilng ,installing in correct alligned position, effecting proper connections,testing and commissioning of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories with off load tap changer(+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 450/400 C first fill oil, having permissible totak less values not exceeding 7.5% of the maximum total loss values for 11KVasperenergyefficiencylevel-2atbasicInsulationlevel conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014. |
638 | Transformersdescribedasaboveandasperthefollowing continuous rating |
639 | 1250KVA |
640 | Supply , Installation, Testing and Comissioning of Outdoor / Inddor TypeIC-OG 33 KV, 630A, 26.3 KA / 1 Sec. 33KV HT VCB Panel with AL. Bus bar. comprising of 33KV Draw out VCB,630A, 26.3 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (IC-OG). Suitable for Indoor & Outdoor Application (IP 5X).Panel with ABB make VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (600 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible. |
641 | Supply installation testing& Commissioning of star ratedCopper wound distribution Transformer ( All the distribution transformer must bestarratedaspernotificationof(BEE)ministryofpower, GoverenmentofIndia)offollowingrating11/0.433KVDelta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & lossesas defined as perIS1180partI2014.includingstandardaccessorieslike conservator,silicagelbreather,Bucholzrelay,radiator,fins,HT cablebox<cableboxes,Off-LTC(+5%to-10%@2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding , ISI markeddrainvalve,DialtypeTemperaturegauge,firstfillingof transformer oil as per IS :335-1953 , Epoxy based paint,including carryingofpre-commissionTesting&ChargingofTransformer completeinallrespect.NABLaccredeated/CPRI/ERDAlab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricityrule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
642 | 63KVA |
643 | 400KVA |
644 | 500KVA |
645 | Supply,Installation,TestingandComissioningof11KV,630A, 20kA / 3 sec, Out door,Extensible type Ring main unit (RMU) in suitable RCC foundation with 2 no. Load break switch & 1 no. VCB / SF6circuitbreakerwithoverload,Earthfault,shortcircuitrelay, copperbusbar,earthingswitch,mechanicalON/OFF/Earth indication, Voltage presence indicator, Ring core protection CT 2.5 VA,10P10aspertransformerrating,Shunttripcoil,Antireflexoperatinghandle,rightanglebootsetc.OEMMusthaveBIS certificate and&shall have submitNABL / CPRI / ERDAlab typetest reportsbefore execution as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
646 | Plate Earthing as per PWD specification for electrical Works as per IS:3043 withcopper Earth plate of size 600mm x 600mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. "B" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
647 | Plate Earthing as per PWD specification for electrical Works as per IS:3043 withcopper Earth plate of size 300mm x 300mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. "B" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
648 | G.I. pipe 50 mm dia as per IS:1239FOR EARTHING SYSTEM |
649 | Supply & Laying following size earth stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm makingconnectionetc.asrequired.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
650 | 50mm x 6mm copper strip |
651 | 50mm x 6mm G.I. ( Hot Dipped) Strip |
652 | 32mm x6mm G.I. ( Hot Dipped) Strip |
653 | 25mm x 6mm G.I. ( Hot Dipped) Strip |
654 | Providing & Laying XLPE insulated as per IS:7098/II/85H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E)inexistingRCC/Hume/Stoneware/PVCpipe/open duct/cabletrenchwithfillingofexcavatedearthintrench,on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size as per points (a), (b), (c) mentioned below:-(a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I (b)conductorshallhaveelectrolyticaluminiumconfirmingtoIS 8130, IS 3975-1999for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c)OEMMusthaveISO9001&14001certificationsforquality assuarance&itsowninhouseNABLlabsetupforalltesting facilities forcables .All above as per pre approved by Engineer in charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR . |
655 | 3 core 120.0 Sq.mm |
656 | Providing & Laying XLPE insulated as per IS:7098/II/85H.T.cable as per PWD specification for electrical Works for working voltage 33 K.V.(E)inexistingRCC/Hume/Stoneware/PVCpipe/open duct/cabletrenchwithfillingofexcavatedearthintrench,on existing cable trays or on surface etc.including making necessary connection, testing etc.as required of size as per points (a), (b), (c) mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I (b)conductorshallhaveelectrolyticaluminiumconfirmingtoIS 8130, IS 3975-1999for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c)OEMMusthaveISO9001&14001certificationsforquality assuarance&itsowninhouseNABLlabsetupforalltesting facilities forcables .All above as per pre approved by Engineer in charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR . |
657 | 3 core 185.0 Sq.mm |
658 | Providing&makingheatshrinkabletypeindoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for11 KV / 33 KV cable with required components, preprationofcableends.Typetestreportshouldbeasper IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streightthrough joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Crosslinking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge includingtesting etc. as required of following sizes. All as per pre approved by Engineer in charge.For additional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR . |
659 | 11 KV End Termination Kit Indoor type |
660 | 3 core 120/150/185 Sq.mm |
661 | 11 KV End Termination Kit Outdoor type |
662 | 3 core 120/150/185 Sq.mm |
663 | 33 KV End Termination Kit Indoor type |
664 | 3 core185/240 Sq.mm |
665 | 33 KV End Termination Kit Outdoor type |
666 | 3 core185/240 Sq.mm |
667 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured/Armouredaluminiumcableof1.1KVgradeasper PWD specification for electrical Worksin existing RCC / Hume / Stoneware/PVCpipe/openduct/cabletrenchwithfillingof excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:-(a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P – I (b)conductorshallhaveelectrolyticaluminiumconfirmingtoIS 8130,IS3975-1999forarmouringofcablesinarmouredcable items,IS5831forsheath,IS10810(Part0to64)fortesting procedures. (c)OEMMusthaveISO9001&14001certificationsforquality assuarance&itsowninhouseNABLlabsetupforalltesting facilitiesforcables.Appropriatetypetestcertificate/OEMtest reportshallbesubmitted.Allaboveasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. |
668 | Armoured Cable |
669 | 400 SQMM,3.5 CORE |
670 | 300 SQMM,3.5 CORE |
671 | 25 SQMM, 3 CORE |
672 | 50 SQMM, 3 CORE |
673 | 120 SQMM, 3 CORE |
674 | 185 SQMM, 3 CORE |
675 | 70 SQMM, 3 CORE |
676 | 95 SQMM, 3 CORE |
677 | 16 SQMM, 3 CORE |
678 | 50 SQMM,3.5 CORE |
679 | 10 SQMM, 3 CORE |
680 | 4.0 SQMM, 3 CORE |
681 | Supply,Fabricating&installingfollowingsizesofpowdercoatedladder type M.S. cable trays with rungs at span of 250 mm including horizontalandverticalbends,reducerstees,crossmembersand otheraccessoriesasrequiredanddulysuspendedfromthe ceiling/wallwithMSsuspendersincludingbolts&nuts,fastners, supports,paintingsuspendersetc.asrequired.Allasperpre approvedbyEngineerincharge.Foradditionaltechnical parameters of products/ work, refer Annexure "A" attached with this BSR . |
682 | 450mm x 50mm x 2.0mm |
683 | 600mm x 50mm x 2.0mm |
684 | Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross membersandotheraccessoriesasrequiredanddulysuspended fromtheceilingwithGIsuspendersincludingGIbolts&nuts, fastners,supportsetc.asrequired.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
685 | 100mm x 50mm x 1.6mm |
686 | 150mm x 50mm x 1.6mm |
687 | 300mm x 50mm x 1.6mm |
688 | 450mm x 50mm x 2.0mm |
689 | Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
690 | 11 KV,2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV |
691 | SITC of floor mounted drowout type PMCC (Indoor, Dury, dust proff IP-4xfrontoperatedwith2mmthicksheetmetal compartmentalised)withallaccessibleparts,headshrinkable sleeves, SMC/DMC bus bar supports, padlocking facility on outgoing feeders etc. |
692 | Incommerfeederfortransformer630A/800A,50KA,ACB3pole,Al BusBars,DigitalMultifunctionmetercompatabletoSCADA, metering,ProtectionCT"s,IDMT3O/C&1E/F,indicating lamps,controlfuse,wiringetc.completeinallrespectofthesize appxo 900(D)X.2400(H)X1000(D) |
693 | Bus Coupler Feeder, 630/800 A ACB ,50KA,3 Pole without release with Al Bus Bars, Protection CT"s ,IDMT 3 O/C & 1 E/F,Indicating Lamps,Control Fses and wiring etc.complete in all respect. (Size : 900(W) x 2400 (H) x 1000 (D) |
694 | Incommer feeder for transformer 1600 A,50KA,ACB 3 pole,Al Bus Bars,DigitalMultifunctionmetercompatableto SCADA,metering,ProtectionCT"s,IDMT3O/C&1E/F,indicating lamps,controlfuse,wiringetc.completeinallrespectofthesize appxo 900(D)X.2400(H)X1000(D) |
695 | Bus Coupler Feeder, 1600 A ACB,50KA, 3 Pole without release with AlBusBars,ProtectionCT"s,IDMT3O/C&1E/F,Indicating Lamps,Control Fses and wiring etc.complete in all respect. (Size : 900(W) x 2400 (H) x 1000 (D) |
696 | 250AMCCBIncomerwithmeteringCTs,multifuctionmeter compatibletoscada,AmpermeterwithSS,Voltmeterwith SS,Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:900(W)X2400(H)X1000(D) |
697 | MCCB up to 100Aas outing CT"s,Ampermeter with SS,Voltmeter withSS,IndicatingLamps,ControlFuse,wiringetc.completeinall respect. Size:600(W)X2400(H)X1000(D) |
698 | 250 A MCCB as outgoing CT"s,Ampermeter with SS,Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinall respect. Size:900(W)X2400(H)X1000(D) |
699 | 400AMCCBIncomerwithMeeteringCT"s,multifuctionmeter compatibletoscada,AmpermeterwithSS,Voltmeterwith SS,Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:900(W)X2400(H)X1000(D) |
700 | S & F of Star delta Starter with MCB, Main and Aux Contactor, O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button ,Control MCB with panel with all accessorieswith following rating |
701 | 7.5 KW to 9.3KW |
702 | SITC ofDraw out type 3/4 pole IP53, IK 08 door interlock Air Circuit Breaker(ACB)asperPWDspecificationforelectricalWorks, conforming to IS/IEC 60947 P - 2 :2003 in existingLT panel suitable for LT installation 440 V, 50 Hz and havingadjustable over load short-circuit, earth fault and withseparate LED indication for each type of fault ,Password protected relase (trip mechanisum) shall confirm to EMI/ EMC test , LCD/LEDdisplay , Thermal memory , pollution degree 4, trip free mechanisum , suitable for ambient 50 degree and utilization catagary B.In built electrical & mechanical anti pumping fearute , 100% rated neutral . ACB shall have separate indicationforservice,test,isolation&maintenanceposition, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break timenotmorethen25ms.Provisionforelectrical&mechanical interlock between ACBs, Min.electricaloperation 10,000 upto 2000 A rating and 5,000 for2500 A. including making connectionsetc. asrequired.OEMshallhavesubmitNABL/CPRI/ERDA accrediated lab type test certificate before execution & All as per preapprovedbyEngineerincharge.Foradditionaltechnical parameters of products/ work, refer Annexure "A" attached with this BSR . |
703 | Microprocessor based release Draw out type ( Motorised charging type ) 3Pole |
704 | 800 A Rating, 50kA |
705 | SupplyandfixingoffollowingaccessoriesforAircircuitbreaker (ACB)compatible with MAin ACB OEM as per PWD specification forelectricalWorks,conformingtoIS/IEC60947P-2:2003 including making connection etc complete in all respect. OEM shall havesubmitNABL/CPRI/ERDAaccrediatedlabtypetest certificate before execution . All as per pre approved by Engineer in charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR . |
706 | Shunt Trip Release |
707 | Under Voltage Release |
708 | Earth Fault Release |
709 | Providing& Fixingof selfhealing IP20MPP type shunt capacitor (banks) as per PWD specification for electrical Works, ISI marked IS:13340-41 / conforming to IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.35 Watt per KVAR. Min over current capacity1.8timesratedcurrent&peakinrushcurrentmin.250 times of rated current,including making connections, testing etc. as required.AllasperpreapprovedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
710 | Heavy dutyThree phase 480 V, 50 Hzcylindrical capacitor (Bank) |
711 | Providing&FixingofIP54onfrontmicroprocessorbasedthree phase sensingpower factor correction relay , IEC / EN 61000-6-(2&4)having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status,alarmoutputforundercurrent,overcurrent,insufficient compensation, communication interface with RS 485,indication of switchingonunits,auto/manualstatus,andshallhaveoverload protection, no volt release , having multi parameter like KW, KVA, KVAR, VTHD, ITHD,metering facility as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reports.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
712 | 12 to 14 stage |
713 | Providing & Fixing ofISO certified company madeCam operated rotary (Auto/manual) switches on existing panel with 2 way and off positionusinghighgradeengineeringmaterialtointernational standards with cam assemblyinsulation of glass filled polyamide withhightrackingindex.Forreliableandstableelectricaland mechanical endurance double butt contacts with silver bi-metal on coppershouldprovided.contactassemblyisofoperatingtemp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc.as required . All as per pre approved by Engineer in charge.Foradditionaltechnicalparametersofproducts/work,refer Annexure "A" attached with this BSR . |
714 | 10 AMP |
715 | Providing& Fixingof440 Volt 3pole capacitor(AC 6B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works,IS/IEC 60947-4-1:2000,insulationvoltage1000V,impulsewithstand voltage 8 KV,Din rail mounting type including making connections, testingetc.asrequired.suitableforfollowingcapacitycapacitor bank. All as per pre approved by Engineer in charge.For additional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR . |
716 | up to 6 KVAR |
717 | 10KVAR |
718 | 25KVAR |
719 | 50KVAR |
720 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, displayof electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus. |
721 | 22KW |
722 | 45KW |
723 | 55KW |
724 | 75KW |
725 | 90KW |
726 | 110KW |
727 | 160KW |
728 | S & F of Star delta Starter with MCB, Main and Aux Contactor, O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button ,Control MCB with panel with all accessorieswith following rating |
729 | 15KW |
730 | 18.5KW |
731 | 433V APFC Panel in cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
732 | 433VIndoor LT Switchgear Panel for POST CHLORINATION SYSTEM in cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor PCC panel switches gear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based relays, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
733 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
734 | Octagonal MS Polesmade of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seamweldandhotdippedgalvanisedinternally&externallyin accordance with IS 2629. (See Table P -01 for specs.) |
735 | 7 Mtr. |
736 | Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
737 | Single arm overhang |
738 | Providing&FixingofIK07IP66protectedLEDStreetLight Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glasscover(UVstablzationreportsubmittedforUVcover)and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wtwith High Power LEDs is to be usedandpotteddrivermustbepotted&hasauniqueBISR number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 VAC and Auto resettingSafety ,InputFrequency 50Hz±3%PowerFactor>0.95driverEfficiency>85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <1000mA shown in LM79 report. The luminaireshall be BIS certifiedandT.C.certified.LifeExpectancyEqualormorethan 50000burninghrswithMinimum70%lumenmaintened,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min = 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/NameEngraved/Embossingondiecasthousingtoallow traceability/authenticity.FixtureshallbeASPERIS10322 Complianced. OEMMusthaveitsowninhouseNABLlabsetupforalltesting facilities forLED fixtures.(LM79/LM80) Certificate/ reportwith liable warranty of product/accessories from OEM shall be submitted.AllasperpreapprovedbyEngineerincharge.Foradditional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR . |
739 | LED Street Light fixture 100 Watt |
740 | Providing&FixingofthermoplasticPolycarbonatecablejunction boxes with IP66 rating of protection & knock out for cable entry/out of following sizes including clamps for holding the box, including cost of DIN rail for MCB mounting, 10 Sqmm 4 pole connectors for cables terminals,threaded cable glands made of polyamide material etc. completeinallrespect.AllasperpreapprovedbyEngineerin charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR . |
741 | 175mm X 150mm X100mm |
742 | Providing & Fixing of Street light bracket made out from following size of " B " class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
743 | 32 mm Dia. |
744 | Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as pertypeofloadandsiterequirement)4KVimpulsewithstand voltage,asperPWDspecificationforelectricalWorkswithISI markedIS8828(1996)/conformingtoIEC60898-12002,IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass3asperIEC,minimumphaseterminationcapacityof 35sq.mm. , conductorline load reversibility, label holding facility , IP 20contactprotectionandfittedwithexistingdistribution board/sheets,min.operation20,000upto32Aratingand10,000 upto63A,5000for80Aratingincludingmakingconnections, testing etc. as required.. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per preapprovedbyEngineerincharge.Foradditionaltechnical parameters of products/ work, refer Annexure "A" attached with this BSR . |
745 | Double pole MCB |
746 | 6 A to 32 A rating |
747 | Supply,Installation,TestingandComissioningofISOcertified company made Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete withIndoorunit(IDU),Outdoorunit(ODU),surface/concealed copperRefrigerantpipingwithinsulation(closedcellelastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and50 hz ,1 phaseACsupplycapableofperformingcooling,dehumidification,air circulation of following capacity with Scroll / rotary compressor. Min 5 year OEM warranty both compressor and PCB.NABLaccredeatedasperIS/ISO/IEC17025standards/CPRI/ ERDAlabtestingreportsasperIS1391(Part-2)2018withOEM certificatemustsubmittedtoengineerincharge.Allasperpre approvedbyEngineerincharge.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
748 | Invertor Type |
749 | 1.8/2.0 TR with 5 star rating of BEE (ISEER not less then 4.5 ) |
750 | Supply&FixingofFRPVCinsulated&sheathed3coreflexible copperconductorasperPWDspecificationforelectricalWorksconfirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from99.99% purity copper, class 5 stranding in acc. to IEC 60228 forlower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity,insulationPVCtypeA,flameretardantasperIS 10810-53, better amperage rating as per VDE 0298 part 4 including makingconnectionetc.asrequired.OEMMusthaveitsownin house NABL lab setup for all testing facilities for wires. All as per pre approvedbyEngineerincharge,makingconnections.For additional technical parameters of products/ work, referAnnexure "A" attached with this BSR . |
751 | 6.0 Sq.mm |
752 | Supplyandinstallationof UL listed,CPRI tested copper bounded steelelectrode of minimum 17.2 mm dia. (as per IEC 62561-2 ) With a minimum coating thickness of 250 micronsandlength of 3 meters, filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends as per point mentioned (a), (b), [c), (d), (e) below :- (a)filledwithanticorrosiveconductivecompoundswiththe permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 35- 40 KA for withstanding 1 second .(b) To ensure the moisture content and electrical conductivity, 25 kg for2000mm&50Kgsfor3000mmofresistanceloweringearth enhancement material shall be used as a backfill compound. The compoundshallbetestedformNABLacredeatedlabforlowresistivity(lessthan0.12Ohm-meter)&highconductivityin nature with carbon as a major contentas per referance of IS 3043-1987,IEEE80-2013(clause14.5d),IEEE837&IER1956with latest amendemnts (c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. (d)Testingofearthresistanceforvalueof5ohmsorlessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e)SelfcertificateforconfirmingabovestandardsfromOEMis mandatory.AllasperpreapprovedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
753 | Providing&Fixingofcoppertape20mmx3mmonparapetor surface of wall fixed with porcelain or bakelite insulator (SP-35) in vertical/horizontalrunasrequired.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
754 | 20mm x 3mm copper strip |
755 | Mesh earthing as per IS:3043 with copper earth strip of size 20 mm x 3 mm to form a mesh of size 3000 mm x 1000 mm in horizontal formation to create equal sections of 500 mm x 500 mm by means of 10 mm brass bolts, & nuts with spring washer, embodying 1 mtr. Belowthegroundlevel,refillingthepitbyalternativelayersof charcoal & salt up to 500 mm with 20 mm dia, 20mm GI "B" class wateringpipeand12mmGI"B"classpipefortheearthwire including all accessories like nuts, bolts, wire mesh funnel and brick masonaryfinishedchambercoveredwithhingedCIcoverand lockingarrangementofsize300mmx300mmcompleteinall respect. |
756 | Providing & Fixing ofIK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps.Integrateddrivermustbepotted&hasauniqueBISR number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wtwith High Power LEDs is to be used.LEDdriverInputVoltageAC120to270VACwithHigh voltageCutoff@>=300VACandAutoresettingSafety.Input Frequency 50Hz±3%, Power Factor >0.95 ,driverEfficiency >85% , THD(I) <10%, driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of InitialLumensmaintained,colorRenderingIndex>70andCCT 5700K±355K.Drivercurrent<1000mAshowninLM79report. ManufacturesWordMark/NameEngraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced. OEMMusthaveitsowninhouseNABLlabsetupforalltesting facilities forLED fixtures.(LM79/LM80) Certificate/ reportwith liable warranty of product/accessories from OEM shall be submitted. AllasperpreapprovedbyEngineerincharge.Foradditional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR . |
757 | High Power LED Flood Light 100W |
758 | From 3.3 KW to 7.5 KW DOL Starter Feeder with MCB, Main and Aux Contactor, O/L Relay, L/R Selector Switch,3 Indicating lamps, Start-Stop Push Button ,Control MCB(Size : 600 (W) x 400 (H) x 600 (D) |
759 | Design,Manufacture,Supply,Installation,Testingand Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheetcompletewithlatestconfiguration,necessaryprogramming software for PLC & SCADA and comprising of all accessories not limited to the following: DI No.30 DO No.26 AI No.6 AO No.2 MCB 16A DP No.2 MCB 6A DPNo.6 SMPS 100-240VAC/ 4.5A / 24 VDC No.1 Selector Switch (Auto/Manual) & Local / RemoteNo.2 Control RelaysLot1 Annunciatorwith24WindowsNOtoNCType Microprocessor Based, WindowSize 75*42mm, 110VAC, with No.1 Electronic HooterNo.1 Control Transformer 200VANo.1 Emergency STOP Push ButtonNo.1 Panel Cooling Fan & FilterNo.2 Panel Light with Door Switch, 7WNo.1 Control Indication Lamp for 24VDC, 220VACNo.3 Push ButtonNo.3 Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc Lot1 PanelHardware,lugs,terminations,ferrules, name plate Etc. Lot1 UTILITY SOCKET 16A, 3 PINNo.2 HMI Display 10 Inch, ColourNo.1 Isolators Dual Output, 24VDCLot1 |
760 | Design,Manufacture,Supply,Installation,Testingand Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheetcompletewithlatestconfiguration,necessaryprogramming software for PLC & SCADA and comprising of all accessories not limited to the following: DI No.102 DO No.98 AI No.22 AO No.16 MCB 16A DP No.2 MCB 6A DPNo.6 SMPS 100-240VAC/ 4.5A / 24 VDC No.1 Selector Switch (Auto/Manual) & Local / RemoteNo.2 Control RelaysLot1 Annunciatorwith24WindowsNOtoNCType Microprocessor Based, WindowSize 75*42mm, 110VAC, with Electronic HooterNo.1 Control Transformer 200VANo.1 Emergency STOP Push ButtonNo.1 Panel Cooling Fan & FilterNo.2 Panel Light with Door Switch, 7WNo.1 Control Indication Lamp for 24VDC, 220VACNo.3 Push ButtonNo.3 Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc Lot1 panelHardware,lugs,terminations,ferrules, name plate Etc. Lot1 UTILITY SOCKET 16A, 3 PINNo.2 HMI Display 12 Inch, ColourNo.1 Isolators Dual Output, 24VDCLot1 |
761 | Modular RTU complete with DI, DO, AI and modbus communication ports and power supply 24 VDC or for variable power supply using batteries, rechargeable batteries, solar or 10.8 V DC to 28.8 V DC with integrated modem; connection to control center via Tele Control Basic,DNP3,IEC60870-5-104andCommunicationprotocols,on-board I/Os min. (8 DI, 4 DQ, 2 AI), configuration and diagnostics per webinterface,RJ45port,mobilecommunicationsantenna (GSM/UMTS),MiniSIMcard,withadapterMicroSIMcardalso, GPRS (Multi-slot Class 10), 35 mm DIN rail mounting, TCP/IP, DNP 3, Open VPN-Client. Panel Enclosure for Compact RTU Location, wall/floormountedalongwithwiringandrelatedaccessoriesand arrangement of mounting of RTU, Modem having IP-5X Protection. Panels shall be self-fabricate type only with Canopy. |
762 | SITCofIntelligentManageableEthernetSwitchesproviding24x 10/100/1000FastEthernetports-and2dualpurposeuplink (provisionforCopper/FibreGigaconnectivity)withLANbased Software.TheLANbasedS/Wsupportsenhancedintegrated security,includingNetworkAdmissionControl(NAC),advanced qualityofservice(QoS),availabilityandscalablemanagementto enable new converged applications |
763 | 4G/3G GPRS VPNmodemwithEthernetbridge/ router/ serial server (RS232/485) Interface to MCC Room ( Wireless Gateway) |
764 | Providing, installation, testing and commissioning of ONLINE UPS SYSTEM,SinglePhase230V,50Hzwith2hourbackupSMF battery bank as per specification |
765 | 1 KVA |
766 | 3KVA |
767 | ProvidingandlayingStranded/FlexibleAnnealedeBarecopper conductor,XLPE/PVCinsulatedsuitablylaiduptogetheroverall polystertapedAl(innersheatedGISteelwireMylar/Drainwire) alongwithATCdrainwire,round/steelarmouredoverallPVC sheathed (ST-1) overall screenedCore armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
768 | 1 SQMM |
769 | 24 CORE |
770 | ProvidingandlayingStranded/FlexibleAnnealedeBarecopper conductor,XLPE/PVCinsulatedsuitablylaiduptogetheroverall polyster taped Al (Mylar tape wrapped) along with ATC Drain wireoverallPVCsheathed(ST-1)overallscreenedPairarmoured instrumentationCablesgenerallyconfirmingtoPAS5308-Part-2-2009. |
771 | 1 SQMM |
772 | 1 PAIR |
773 | ProvidingandlayingXLPE/PVCinsulated&PVCsheathed armoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavationj of 30 CmX75 Cm size trench 25 Cm thick under layer of sand and Iind class bricks covering |
774 | 6C x 1.5 sq.mm |
775 | 4C x 1.5 sq.mm |
776 | Providing,Installation,TestingandCommissioningofUltrasonic Level Transmitter : Principle : Timeof Flight/ Sensor MOC PP / PowerSupply:24VDC/Output:4-20mA/Display:Integral displayfor programming andDisplayReading/ IP 66/ Accuracy ±1% |
777 | 0-5M |
778 | Providing,Installation,TestingandCommissioningofPressure Transmitter : Range:0-10Bar / Power Supply:24 V DC / Output: 4-20mA withHART / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 |
779 | Providing,installation,testingandcommissioningofDiaphragm TypePressureGaugesDialsize150mmglycerinefilled shatterproofglass,Overrangeprotection:125%ofmaximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminium |
780 | Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material of sensor and other wetted parts: SS type 316, Housing: Die cast aluminium, Switch type: Microswitch, Repeatability: ± 1% of span, Switch Contacts: 2 NO + 2 NC |
781 | Providing,installation,testingandcommissioningofLevelSwitch (Conductivity) Conductivity Probes, Probe insulation: Teflon, Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminium |
782 | Rigid for lengths ofup to 3 Mtr. |
783 | Providing,installation,testingandcommissioningofCapacitance Level Transmitter for tank /sump level Accuracy: ±1.5 % of span, Probe type: Rod, Probe material: SS type 316, Weather Protection Class:IP65ofIS13947PartI,Output:4-20mADC(Isolated), Material of wetted parts: SS 316, Probe insulation material: Teflon, Stilling pipe: SS type 316 with perforations |
784 | Supply,Installation,TestingandCommissioningofOnline MultichannelandMultiparameterTransmitter/ConverterforLiquid Analysis Sensors as per CPCB/SPCB guidelines. |
785 | Dual Channel (2 Sensor Input) |
786 | Four Channel (4 Sensor Input) |
787 | FRC Sensor Range :- 0.05 to 20 mg/l |
788 | Turbidity SensorRange :- 0-4000 FNU |
789 | pH Sensor Range :- 0-14 |
790 | FRC Sensor Range :- 0.05 to 20 mg/l |
791 | Supply, Installation, testing and commissioning of SCADA System at MasterControlCentrecompletewithPCserver,monitor, communication modules, printers, 2 Nos. of 60"LED Display of latest resolution and configuration, 4 Nos of 32"" Operator console ( 1 No. of Engineering, 1 No. of operator console, 1 No. of Historical and 1 No. of Web Server) including control desk, chairs, storage racks etc., requiredhardware,softwarecompletewithallaccessoriesandin line with Technical Specification. |
792 | Providing, installation, testing and commissioning of ONLINE UPS SYSTEM,SinglePhase230V,50Hzwith2hourbackupSMF battery bank as per specification |
793 | 5KVA |
794 | Plate Earthing as per PWD specification for electrical Works as per IS:3043 withcopper Earth plate of size 300mm x 300mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. "B" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
795 | Supply & Laying following size earth stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm makingconnectionetc.asrequired.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
796 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
797 | Supply, installation, testing and commissioning ofMNRE approved off GridSolar Panels with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS fabricated structure 120 micron hot dip galvanized iron , showing arrangement of panel in available space and installation ofPV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in RCC. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structureandsuitable provision shall be included in tender document. |
798 | Supply of GSM /GPRSbased data transmitter for Bulk Flowmeter (woltman Pulse Output only ), Battery Powered -7.4V,battery life 3-5 Years,(1 no Data transmit in aday),4-20mA From Pressure RS485 Display-16*2 LCD,Encloser-165*120*65 mm,ABS Protection-IP65,Operating tempreature -55 Deg. C |
799 | O&M Cost for 10 Years 5.25 % of total cost except Internal distribution network and FHTC |
800 | For the 1st Year of O&M after DLP |
801 | For the 2nd Year of O&M after DLP |
802 | For the 3rd Year of O&M after DLP |
803 | For the 4th Year of O&M after DLP |
804 | For the 5th Year of O&M after DLP |
805 | For the 6th Year of O&M after DLP |
806 | For the 7th Year of O&M after DLP |
807 | For the 8th Year of O&M after DLP |
808 | For the 9th Year of O&M after DLP |
809 | For the 10th Year of O&M after DLP |
Copyright © 2022 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail