Execution Testing, Commissioning Of Pumping Mach, kota,Rajasthan Tender

Public Health Engineering Department has published a tender for Execution Testing, Commissioning Of Pumping Machinery , Etc In 749 Villages, Including 10 Years Ond M Under Nonera Wsp Under Jjm District Kota And Bundi. ( Package-Ii ) . Submission Date for this Tender is 06-09-2022 and Tender estimated value is 8319700000. Pump Supply Tenders in kota Rajasthan. Bidders can get complete Tender details and download the document.


Tender Notice

33408122
Corrigendum : Execution Testing, Commissioning Of Pumping Machinery , Etc In 749 Villages, Including 10 Years Ond M Under Nonera Wsp Under Jjm District Kota And Bundi. ( Package-Ii )
Works
Indian
Rajasthan
kota
06-09-2022

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Execution Testing, Commissioning Of Pumping Machinery , Etc In 749 Villages, Including 10 Years Ond M Under Nonera Wsp Under Jjm District Kota And Bundi. ( Package-Ii )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Aug-2022 corrigendum 01 Technical Bid 06-09-2022

Key Value

Document Fees
INR 50000 /-
EMD
INR 166394000.0 /-
Tender Value
INR 831.97 Crore /-

Attachment

FileName File Description File Size
0ee33d56-87b5-4e44-a4b1-b0b9b9bdb2fe.html Tender Notice 45.0 KB
BOQ_515224.xls Tender Document 1.3 MB
TD13.pdf Tender Document 21.9 MB
Tendernotice_1.pdf Tender Document 1.4 MB

BOQ Items

Name of Work: NONERA PACKAGE-2, 3 & 4 WATER SUPPLY PROJECT UNDER JJM. DISTRICT- KOTA&BUNDI
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil
2Add extra for trenches for every additional lift over item no 4.1
3Above 1.5 mtr and up to 3.0 mtr.
4Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .:
5Ordinary rock
6Hard rock (requiring blasting)
7Add extra for trenches for every additional lift over item no 4.3
8Above 1.5 mtr and up to 3.0 mtr.
9Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
10100 mm
11150 mm
12200 mm
13250 mm
14300 mm
15350 mm
16400 mm
17450 mm
18500 mm
19600 mm
20Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-9 gradeS&Spipesas per IS:8329-2000 (amendeduptodate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
21200 mm
22Providing, lowering, laying and jointing in trenches,  standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.
23HDPE PE-80PN-6
2475 mm
2590 mm
26110 mm
27Providing, lowering, laying and jointing in trenches,  standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.
28HDPE PE-80PN-6
29125 mm
30140 mm
31160 mm
32180 mm
33200 mm
34225 mm
35Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.
36100 mm pipe
37150 mm pipe
38200 mm pipe
39250 mm pipe
40300 mm pipe
41350 mm pipe
42Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
43Manually Operated CI Sluice valve of Class PN-1.0
4480 mm HW
45100 mm HW
46125 mm HW
47150 mm HW
48200 mm HW
49250 mm HW
50300 mm HW
51350 mm HW
52400 mm with Gear
53450 mm with Gear
54500mm with Gear
55600 mm with Gear
56Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valveof approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedupto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1.HP Orifice-HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.
57Class PN 1.0
5850 mm
5980 mm
60100 mm
61150 mm
62Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirfing to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
63Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 (Junction Valve)
6480 mm dia
65100 mm dia
66150 mm dia
67200 mm dia
68250 mm dia
69300 mm dia
70350 mm dia
71400 mm dia
72450 mm dia
73500 mm dia
74700 mm dia. With Gear
75800 mm dia. With Gear
76Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6
77100 mm dia
78150 mm dia
79200 mm dia
80250 mm dia
81300 mm dia
82350 mm dia
83Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
84Class PN 1.6, Manually Operated with Gear
85300 mm dia
86350 mm dia
87400 mm dia
88Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions,Face to face dimensions as per IS 5312 (part -1):2004Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brasswith EPDM/NBR "O "ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel)Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
89Class PN 1.6
90100 mm dia
91150 mm dia
92200 mm dia
93250 mm dia
94300 mm dia
95350 mm dia
96Providing, lowering, laying, aligning, fixing inposition CI D/F short body pattern type butterfly valves having body, disc and end cover in graded cast irongenerally conforming to (IS13095/1991amendedupto date), synthetic rubber faced ring secured on disc by retaining ring with SS steel screw stub shaft of SS riding in teflon bearing including C.C. foundation/ structural steel support, material,labour,testingalongwith pipe line andcommissioning asperTechnical Specifications andasper direction of Engineer in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work
97Manually Operated Butterfly Valve PN-1.0For Junction/ sectional Valves
98200 mm dia (With Gear Operated)
99300 mm dia (With Gear Operated)
100350 mm dia (With Gear Operated)
101400 mm dia (With Gear Operated)
102450 mm dia (With Gear Operated)
103500 mm dia (With Gear Operated)
104600 mm dia (With Gear Operated)
105Providing, lowering, aligning, fixing in position and Jointing in pipe line, combination Air Release Valve Kinetic type with single chamber housed Double orifice and have 3 functions, large Air exhaust, small Air venting and large air intake during vacuum of pipeline of approved makes of following pressure rating and dia and as per following specifications:Governing standard - AWWA C512 ,Body and bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865,Float & internal trim: AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBRDrilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside Fastners - CS/ Galvenised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, Big orifice size should be equal or larger than the inlet flange bore, for fully comply with AWWA C512.), Valve including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.
106Class PN 1.6
10750 mm dia
10880 mm dia
109100 mm dia
110150 mm dia
111200 mm dia
112Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0
11380 mm dia.
114100 mm dia.
115125 mm dia.
116150 mm dia.
117200 mm dia.
118250 mm dia.
119300 mm dia.
120350 mm dia.
121400 mm dia.
122450 mm dia.
123500 mm dia.
124600 mm dia.
125AIR VALVE PILLAR -Construction ofRCC Air valve pillar of following size including required earth work (PCC 1:4:8 )circular pillar of M-20 cement concreteof suitable size as per GAD including providing fixing of GI pipe with flang and required fitting for air valve complete as per specification and scope of work. ( Item based on PWD BSR Kota 2019)
126Air valve piller25 mm
127Air valve piller 50 mm
128Air valve piller 80 mm
129Air valve piller 100 mm
130Air valve piller 150 mm
131VALVE CHAMBER- Construction ofRCC Valve Chamberof following size including required earth work (PCC M-10, 10 CM th. ) RCC vertical wallsin M-20grade cement concreteof suitable size as per GAD including providing fixing ofReinforced Ferro cement Drain cover designed for class "AA" loading complete as per specification and scope of work.
132Valve Chamber size0.90X1.20 Valve size up to 150 mm
133Valve Chamber size1.50X1.20 Valve size up to 200mm to 300 mm
134Valve Chamber size1.50X1.80 Valve size up to 350mm to 450 mm
135Valve Chamber size1.80X2.10 Valve size up to 500mm to 600 mm
136Valve Chamber size2.40X2.10 Valve size up to 700mm to 900 mm
137VALVE CHAMBER- Construction ofRCC Valve Chamberof following size including required earth work (PCC M-10, 10 CM th. ) RCC vertical wallsin M-25grade cement concreteof suitable size as per GAD including providing fixing ofReinforced Ferro cement Drain cover designed for class "AA" loading complete as per specification and scope of work.
138Valve Chamber size0.90X1.20 Valve size up to 150 mm
139Construction of CC Road
140Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
141Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.
142Bituminous courses
143Granular courses
144Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work.
145Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shallbe made for trench width more than specified,complete work as per technical specification and scope of work.
146M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
147Removing& Re-fixing of Precast concrete interlocking blocks by manual, stacking of serviciable & non serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block against damaged, including alllead and lift as per Technical specifications.(Interlocking blockmanufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm)
14860 mm thick.
14980 mm thick.
150100 mm thick
151Repair of Bituminous Roadusing GSB 15 cm thick, WBM 15 cm thick in two layers , 20 mm thick bitumin carpet and sand seal coat Complete as per specification and scope of work. ( based on Kota 2019 PWD BSR Road 2019
152Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement.
153M20 grade Nominal Mix
154Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc.
155Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor Three level.
156Hot rolled deformed bars (IS : 1139).
157Thermo-mechanically Treated bars (Conforming of relevent IS code)
158SITC of Bulk Flow Meter with removable mechanism class "B" confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete:Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.
159BFM 80 mm
160BFM100 mm
161BFM125 mm
162BFM 150 mm
163BFM200 mm
164BFM 250 mm
165SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304,Electrode : SS AISI 316L /Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.
166EFM 80 mm
167EFM100 mm
168EFM 125 mm
169EFM 150 mm
170EFM 200 mm
171EFM 250 mm
172EFM 300 mm
173EFM 400 mm
174EFM 450 mm
175Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below: 1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm, 3. Stone masonary in CM: 1:6 section of foundation above PCC,600 mm (W ) x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm. 5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6. 6. Expansion joint shall be on every 30 mtr. 7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided. 8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done.
176IPS at notara WTP
177Digod-IPS
178RajpuraCPS
179KAPREN WTP
180GENDOLI KHURD-IPS
181LABAAN-CPS
182KARWAR-CPS
183SARSALA-CPS
184BAJAR-CPS
185KHATKAR-CPS
186Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.
187IPS at notara WTP
188Digod-IPS
189RajpuraCPS
190KAPREN WTP
191GENDOLI KHURD-IPS
192LABAAN-CPS
193KARWAR-CPS
194SARSALA-CPS
195BAJAR-CPS
196KHATKAR-CPS
197Construction of Pump house of required size suitable for installation ofpumping sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.
198IPS at notara WTP
199Digod-IPS
200RajpuraCPS
201KAPREN WTP
202GENDOLI KHURD-IPS
203LABAAN-CPS
204KARWAR-CPS
205SARSALA-CPS
206BAJAR-CPS
207KHATKAR-CPS
208Construction and commissioning of RCC flat slab Over Head Service Reservoir of following capacity and staging including all material and labour charges as per the Scope of work and Technical Specification, consisting of the following main activities: -
209a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall. e) Successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab.
210j) Providing and fixing water level indicator (float type). k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm p) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
211Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 15 M
21250 KL capacity
213Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 18 M(6% increase)
21450 KL capacity
21575 KL capacity
216Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -
217a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e)Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type).
218k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
219Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 18 M
220100 KL capacity
221150KL capacity
222200KL capacity
223250KL capacity
224300KL capacity
225350KL capacity
226Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 20 M
227100 KL capacity
228150KL capacity
229200KL capacity
230250KL capacity
231300KL capacity
232Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 22 M
233150 KL capacity
234250 KL capacity
235Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 18 M
236100 KL capacity
237150KL capacity
238200KL capacity
239250KL capacity
240300KL capacity
241350KL capacity
242Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 20 M
243150KL capacity
244300KL capacity
245Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 22 M
246150KL capacity
247200KL capacity
248250KL capacity
249400KL capacity
250Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 24 M
251200KL capacity
252250KL capacity
253300KL capacity
254Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -
255a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.
256h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
257Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4
25825 KL Capacity-1 Nos
25980 KL Capacity -1 Nos
260200KL capacity
26120 KL Capacity -1 Nos
26230 KL Capacity -1 Nos
26340 KL Capacity -1 Nos
26450 KL Capacity -1 Nos
265150 KL Capacity -1 Nos
26670 KL Capacity -5 Nos
267200 KL Capacity -1 Nos
268Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: -
269a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. . b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.
270h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k)Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
271Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3.
272700 KL capacity
2731200 KL capacity
274Construction of RCC (Flat slab type) Rectangular Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase in side and out side. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.
275d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab.j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m)Construction of inlet chamber, and valve chambers n) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
2763500 KL
2772500 KL
2781500 KL
2791900 KL
2802500 KL
2812700 KL
2822800 KL
283Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications:Body-Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030,Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 420/ Gr 1.4021Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2.Insersion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied bothinside and outside . Suitablesupport structure as per directions of EIC including jointing & jointing material,labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge.Note: Rates are exclusive of tail piece/ dismantling joints and
284Plunger Type Flow Control Valve
285200mm dia
286300mm dia
287400 mm dia
288500 mm dia
289Providing,installation, testing and commisioning of vacuum Feed Gas Chlorinator with all assessories and making connection with existing pipeline required including supply & instalation of trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragm Valve on injector inlet & outlet, 32 OD uPVC pipe for chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GM gate valve on pump suction & delivery, 25 NB GM "Y" type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressure gauge with Isolated valve on pump delivery and chlorine booster pump with motor of required capacity complete in all respect as per specification and the direction of the Engineer
2901 kg/hr capacity
2912 kg/hr capacity
2923 kg/hr capacity
293Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ.
294Discharge 141 to 160 LPS and head 41 to 50 M
295Discharge 101 to 120 LPS and head 61 to 70 M
296Discharge 121 to 140 LPS and head 31 to 40 M
297Discharge 181 to 200 LPS and head 41 to 50 M
298Discharge 61 to 70 LPS and head 51 to 60 M
299Discharge 71 to 80 LPS and head 71 to 80 M
300Discharge 20 to 30 LPS and head 81 to 90 M
301Discharge 20 to 30 LPS and head 71 to 80 M
302Discharge 41 to 50 LPS and head 81 to 90 M
303Discharge 31 t0 40 LPS and head 51 to 60 M
304Discharge 81 to 90 LPS and head 31 to 40 M
305Discharge 161 to 180 LPS and head 51 to 60 M
306Discharge 20 to 30 LPS and head 51 to 60 M
307Discharge 31 t0 40 LPS and head 61 to 70 M
308Discharge 101 to 120 LPS and head 51 to 60 M
309Discharge 41 t0 50 LPS and head 61 to 70 M
310Discharge 31 t0 40 LPS and head 61 to 70 M
311Discharge 20 to 30 LPS and head 71 to 80 M
312Discharge 20 to 30 LPS and head 61 to 70 M
313Discharge 41 t0 50 LPS and head 51 to 60 M
314Discharge 20 to 30 LPS and head 41 to 50 M
315Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
316Centrifugal Monoblock Pump set (Single Stage)
3179.3 KW (12.5 HP)
31811.0 KW (15 HP)
319Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel)as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer.
320100 mm dia.
321150 mm dia.
322200 mm dia.
323250 mm dia.
324300 mm dia.
325600 mm dia
326Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
327Dia of Pipe: 300.00 mm (I.D)
328Thickness of Pipe
3295.0 mm
330300 mm dia (5mm Thick)
331Dia of Pipe: 400.00 mm (I.D)
332Thickness of Pipe
3335.0 mm
334Dia of Pipe: 500.00 mm (I.D)
335Thickness of Pipe
3365.0 mm
337Dia of Pipe: 600.00 mm (I.D)
338Thickness of Pipe
3395.0 mm
340Dia of Pipe: 900.00 mm (I.D)
341Thickness of Pipe
3425.0 mm
343Dia of Pipe: 700.00 mm (I.D)
344Thickness of Pipe
3455.0 mm
346Dia of Pipe: 800.00 mm (I.D)
347Thickness of Pipe
3485.0 mm
349Dia of Pipe: 550.00 mm (I.D)
350Thickness of Pipe
3515.0 mm
352600 mm dia (7mm thick)
353Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes
354150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m)
355200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)
356250 mm dia NB (Thickness of pipe 7.1 mm & mass of tube 46.57 Kg/m)
357Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge.
358MS pipespecialsupto600mmdia (withminimum5mmthickness sheet)
359Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proofKinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammended up to date) Body, High pressure cover , Low pressure cover, Cowl andJoint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will have a screen to prevent Tamper of float,with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amendedupto date) PN 1.6 ratings Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.
360Class PN 1.6
36140 mm
36250 mm
36380 mm
364100 mm dia
365200 mm dia
366Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete inI/rail section upto intake height.for hoisting and fixing for every additional one metre or part thereof beyond 10 mtr height.
367Providing and fixing double flanged ISI markedGI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.
36850 mm
36965 mm
37080 mm
371Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD.
3722.2 KW (3.0 HP)
373Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover.
374Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air ValveFlanged/ Screwed type of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedupto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1,Body seat ring - Leaded tin bronze/ SS , Seal ring and face ring - EPDM/NBR, Ends flanged according to IS 6418 or screwed Screwed type shall have extcrnal pipe threads conforming to IS 554Fastners - CS Epoxy paint inside outside of food grade safe for drinking water ,Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.
375Class PN 1.0
37625 mm S-1 Type
377VTC - Construction ofvillage lavel transfer chamber and meter room, work including require earth work PCC 1:3:6 under floor & for foundation, walls of chmber constrected by RCC M-20, with Fiber reinforced Ferro cement drain cover (light duty). Construction of brick masonary meter room above GL,23 cm thick Brick masonary walls over stone masonary foundation coverd by RCC roof, CC flooring, MS sheet door,GI pipe etc. with locking arrangments
378Providing Household Tap Connectionas per technical specification and approved drawing as per relevant IS code (amended up to date) from uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PVC/MS saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil (excluding road); depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including MS/PVC saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valveand specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipe with fittings in the premises for fixing a tap / meter box (excluding),including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid seperately.
379For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.
380Providing Household Tap Connectionas per technical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid seperately.
381For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.
382P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore.
383Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge..
384Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.
385Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification.
386300 mm Dia 8 mm thick casing pipe.
387500 mm Dia 8 mm thick casing pipe .
388600 mm Dia 10 mm thick casing pipe .
389700 mm Dia 10 mm thick casing pipe .
390Providing and applying 100% Solids,Rigid, DTM Polyurethane Coating to internal surface of M.S. Pipe as per AWWA C222 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Polyurethane Coating shall be NSF/WARS/SS-375 approved for drinking water.
391Providing and applying following Coating to the External surface of MS pipes, including preparation of surface by cleaning as per ISO 8502-3/ SSPC-SP10/ NACE No.2 near white blast cleaning and abrasive blasting to a finish to SA 2.5 as per ISO: 8501-1 and surface profile / anchor profile of 50-75 / 75-100 microns as per ISO: 8503-2, including field joint coating at site complete as per Technical specifications and direction of Engineer –in-charge: 3 LPE (3 Layer Polyethylene) / DFBE (Dual Layer Fusion Bonded Epoxy)/ PU (Polyurethane)/ Polyolefin Tape coating .
392Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centering, shuttering and reinforcement including curing, compaction, finishing with rendering in cement sand mortar 1 : 3 (1 cement : 3 coarse sand) and making good the joints and Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete improve workability without impairing strength and durability as per direction of Engineer-in-charge. M-25 grade reinforced cement concrete. All wiork up to plinth level.
393Providing M-25 grade concrete
394Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc.
395Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like with pumping set of following H.P. including P.O.L. complete.
39610 to 19 H.P.
397Banking excavated earth in layers not exceeding 20cm. in depth breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers, and rolling every 3rd and top- most layer with power roller of 8-10 tonne capacity and dressing up in embankments for roads, flood banks marginal banks, and guide banks etc. lead up to 50 Mtr. and lift up to 1.5 Mtr. All kinds of soils
398Carrage of Earth, Sand, Lime, Morrum manure or sludge Leadupto2 KM for Earth
399SITC of IEC, TUV certified, MNRE approved Solar Panels suitable for Rooftop as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and structure, showing arrangement of panel on available space, installation ofPV module structure on shed / roof as per drawings including super structure wherever necessary as per drawin. Mountingstructure suitably designto withstand wind velocity upto 150km/hr. Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5years warranty. All cabling up to panel and metre, earthing etc. required accessiories and taxes are inclusive. Note: There shall be 5 year service warranty for solar panel and mounting structureandsuitable provision shall be included in tender document.
400For Pumping Stations
401Digod IPS
402Rajpura CPS
403PEEPALDA KALAN-CPS
404BANGROD CPS
405RAMPURIYA CPS
406For 2 HP Pumps (1.92*2)
407GENDOLI KHURD-IPS
408LABAAN-CPS
409KARWAR-CPS
410SARSALA-CPS
411BAJAR-CPS
412KHATKAR-CPS
413For 1 HP Pumps (0.96*3)
414For 2 HP Pumps (1.92*4)
415For 3 HP Pumps (2.88*1)
416For 5 HP Pumps (4.88*3)
417Providing, installation, testing and commissioning of AC submerssible pump sets with inbuilt or individual solar pump controllerwith Maximum power point tracking (MPPT) for optimally use the solar panel and maximize water discharge to deliver maximum water during the day including PVC flat submersible cable from controller to motor pumps.. Solar pumpshall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope . Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit, accidental short circuit and reverse polarity should be provided. A good reliable on/off switchbe provided. The cable shall be ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date. The duty condition of pump set shall be as per scope of work and entire work shall be executed as per technical specification and direction of Engineer in charge.
4181.5 KW (2.0 HP) (3+3)
4190.75 KW (1.0 HP) (3+3)
4201.5 KW (2.0 HP) (4+4)
4212.2 KW (3.0 HP) (1+1)
4223.7 KW (5.0 HP) (3+3)
423Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
42450 mm dia
42565 mm dia
42680mm dia
427Providing, lowering, aligning, fixing in position in pipe line, CIdouble flangedDual plate check valave of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications:Body & Cover of Grey cast iron ofIS:210/ FG200 , Disc / plates - Cast steel ,Disc seal ring of EPDM/ NBR (food grade quality) ,Body seat of SS ,Face to face dimensions as per API: 594 ,Flanges Drilled as per IS:1538.Epoxy (Non-Toxic & suitable for drinking water) applied on body & coverinside and outside . Shaft/Stop Pin of SS- AISI- 304/410 , Hinge SS AISI 316/304 / CS ,SpringSS AISI 316/304 , Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal.Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.as per API: 594 and flanges as per ISS of approved makeof following Class and dia complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
428Class PN 1.0
42980 mm dia
430Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. "B" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
431Pressure gauge-1 to 1.0 kg/sq.cm with isolation vave
432Providing, installation, testing and commissioning of glycerin filledPressure gauge of following ranges with isolation valve and tap offpipe complete in all respect as per technical specification and as perdirection of Engineer.
4330 to 4.0 / 0 to 6.0 / 0 to 10.0 kg/cm²
434Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.
435(I) For Solar/Electrical driven pump sets - 2.5 M X 2.5 M (12Nos.)
436(I) For Solar/Electrical driven pump sets - 2.5 M X 2.5 M (1 Nos.)
437Provision of J2 Types Quarter
438provision of store cum office
439Provision of Inspection bungalow
440Provision of Meeting Hall
441Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 meter.All kinds of soil.
442Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering =All up to plinth leve
4431:4:8 (1Cement :4 Course Sand :8 Graded stone aggregate 40 mm nominal size
444Flyash Brick work with flyash Bricks of class designation 75 in superstructure above plinth level upto floor Three Level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)
445Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix : 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size)
446Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor Three level for :
447Walls (any thickness) including attached pilasters, buttresses plinth and string course.
448Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping, bed plates, anchor blocks, sills, chhajjas lintel, beam etc.
449Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
450Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level.
451Thermo Mechanically treated bars
452Cement mortar 1 : 6 (1 cement : 6 coarse sand)
453Plaster on new surface on walls in cement sand mortar 1:3 including raking of joints etc. complete fine finish:
45425 mm thick.
455Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with "code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping.
456250 mm nominal bore
457Supply & lowering air line of 25mm dia, G.I. pipe "B" class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc.
458Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge.
459Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids
460Size 9 to 12 mm
461Size 3 to 5 mm
462Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids.
463P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant.
464110 mm dia
465160 mm dia
466P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:
467Cuppler
468110 mm dia
469160 mm dia
470Tee
471110 mm dia
472160 mm dia
473Bend 87.5
474110 mm dia
475160 mm dia
476Pipe Clip
477110 mm dia
478Extra for supplying and fixing of 560 mm dia Ductile Iron manhole frame & cover, Hinged Type, Heavy Duty with test load of 400 KN, class D-400 as per BS EN 124, in place of RCC/ SFRC manhole frame & cover (ED/EHD) in manhole.
479Providing and fixing of reinforced Ferro-Cement drain covers designed for "AA" class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc. Standard Size 2100x500mm (150mm thick) for span 1201 to 1500mm
480Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor Three level. Thermo-mechanically Treated bars (Conforming of relevent IS code)
481Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI –92 num DO – 92 num AI –16 num AO – 8 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 30 num Selector Switch - 15 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer – 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 30 num Wiring + TB etc – 1 lot Hardware – 1 lot
482HIM Display, Colour, 12" having Ethernet Port, USB Port ect.
483Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 800 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithOperator Station(PC)including,necessaryprogramming softwareforPLC&SCADAandcomprisingofall required accessories not limited to the following: ProgrammableLogicController(PLC)withDual redundantCPU,PowersupplymoduleforIO& Processorrack(StandardDC),Backup Interface/ExpansionModule(BCM/BEM),Rack (Backplane) 10 slots for IO and Processor – 1 lot DI – 288 num DO – 176 num AI – 32 num AO – 16 num Ethernet Switch – 3 num , MCB 10A DP – 1 num MCB4ADP – 2 num , MCBSP2A – 10 num , MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num , Push Buttons – 30 num Selector Switch – 15 num , Control Relays – 150 num Annunciatorwith24WindowsNOtoNCType , MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter , Control Transformer – 1 num Emergency PB – 1 num , Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 30 num Wiring + TB etc – 1 lot Hardware – 1 lot HMI – 2 num OperatorStationincluding,Corei5processor,8GB DDR-3RAM,500GBHDD,DVDRWDrive,RS-232/485Ports,1ParallelPort,4nos.USBPort,2x EthernetCards,Keyboard,opticalmouse,32""monitor, Latest windows professional ver., etc. – 02 num ProgrammingandtroubleshootingsoftwareforHMI– OWS – 1 lot Colour Printer A4, Lasejet – 1 num
484Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface.
485Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank.
4863KVA
4872KVA
4885KVA
489Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 800 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithOperator Station(PC)including,necessaryprogramming softwareforPLC&SCADAandcomprisingofall required accessories not limited to the following: ProgrammableLogicController(PLC)withDual redundantCPU,PowersupplymoduleforIO& Processorrack(StandardDC),Backup Interface/ExpansionModule(BCM/BEM),Rack (Backplane) 10 slots for IO and Processor – 1 lot DI – 288 num DO – 176 num AI – 32 num AO – 16 num Ethernet Switch – 3 num MCB 10A DP – 1 num , MCB4ADP – 2 num MCBSP2A – 10 num , MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num , Push Buttons – 30 num Selector Switch – 15 num , Control Relays – 150 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter , Control Transformer – 1 num Emergency PB – 1 num , Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num , Control Indication Lamp – 30 num Wiring + TB etc – 1 lot Hardware – 1 lot HMI – 2 num OperatorStationincluding,Corei5processor,8GB DDR-3RAM,500GBHDD,DVDRWDrive,RS-232/485Ports,1ParallelPort,4nos.USBPort,2x EthernetCards,Keyboard,opticalmouse,32""monitor, Latest windows professional ver., etc. – 02 num ProgrammingandtroubleshootingsoftwareforHMI– OWS – 1 lot Colour Printer A4, Lasejet – 1 num
490CentralDataLogger-PCbasedDataAcquisitionSystemwithXR PremiumLicenseSoftwaresuitableforStoring,Logging,Reporting, Printingdata,Validationandcommunicatingwithabove offeredLocalDAS.PCwithspecificationsasunder:PentiumDual Core 2 Processor, 2 GB RAM, 250GBHDD, CD/DVD Combo Drive, 19"TFTMonitor,2serial&1parallelports,Standard WINDOWSOperatingSystem,standardkeyboard,mousewithpad and Color Laser printer.
491Optic Fibre Cable, Armoud, Single Mode , 6 Core, Industrial Application,
492TP-Link Gigabit SFP to RJ45 Fiber Media Converter, Fiber to Ethernet Converter -10/100/1000Mbps RJ45 Port to 1000Base-LX Single-Mode Fiber. One RJ - 45 and two Fiber port (SC type connector), Auto MDI support, AC 240V or DC +5V, Store and Forward Mode, 10Km 1000 Base-T to 1000 Base-LX.
493Supply, Installation, Testing Commissioning of SERVER type: 2U rack server with configuration flexibility;Processor(s): TwoDual Core 64-bit Intel CPUs, 2.4 GHz;Memory: 8 GB RAM;Local Storage: Two hard drives, 1TB each, RAID 1 mirrored;SCSI Controller: Ultra 320 on board and PCI Ultra 320;Operating System: Windows Server 2012, Enterprise Edition or higher;Network adapter: Dual Embedded Gigabit Ethernet NIC & PCI NIC Power Supply: Redundant 750Watt hot-plug power supply; andKeyboard/monitor: Keyboard and monitor inside the rack. Make - HP/DELL/ LENOVA
494SITCof55""FlatScreenHDLEDTVwithremotecontrolandwall mountunit/floorstandcompletewithmakingconnectionsetc.as required Sony/ Samsung/Panasonic)
495SITCofIntelligentEthernetSwitchesproviding24x10/100Fast Ethernetports-and2dualpurposeuplink(provisionforCopper/ FiberGigaconnectivity)with LAN based Software.TheLANbased S/Wsupportsenhancedintegratedsecurity,includingNetwork AdmissionControl(NAC),advancedqualityofservice(QoS), availabilityandscalablemanagementtoenablenewcoverged applications
496ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelarmouredoverallPVCsheathed(ST-1) overallscreenedCorearmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009.
4971 SQMM, 24 Core
498ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009.
4991 SQMM, 1 Pair
500ProvidingandlayingXLPE/PVCinsulated&PVC sheathed armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction.
5014C x 2.5 sq.mm
5024C x 1.5 sq.mm
503Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66
5040-5M
505Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2"NPT(M)/Accuracy:0.15%Protection: IP67
5061/2" M (NPT)
507Providing,installation,testingandcommissioningofDiaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass,Overrangeprotection:125%ofmaximumpressure,Material ofsensorandotherwettedparts:SStype316,Housingmaterial: Die cast aluminum
508Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material ofsensorandotherwettedparts:SStype316,Housing:Diecast aluminum,Switchtype:Microswitch,Repeatability:±1%ofspan, Switch Contacts: 2 NO + 2 NC
509Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum
510Providing,Installation,TestingandCommissioningofpH ANALYSER for WaterApplication :Transmitter : Range:0-14pH, PowerSupply230VAC,Input:OneDigitalSensor,Output:4-20mAHART,IP66Protection/Txprotectioncoverrequired/ SensorRange0-14pH,abletotransmitdigitalsignalto transmitter,calibrationdatacanbetransferredtoTransmitter, process temp: 65 deg cen/ flow through teeMOC SS
5110-14 pH
512Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l
5130.05 -20 mg/l
514Providing,Installation,TestingandCommissioningofTURBIDITY ANALYSER for WaterApplication : Turbidity Measuring range: 0 to 100NTU;Accuracy:+/-2%ofreadingor+/-0.02NTU;Compliance toUSEPA180.1,Withinbuilttransmitterwith4-20mAoutput, Relay contacts & Modbus communication
5150 - 100 NTU
516PRE-WIRED RTU Panel Compact RTU for variable power supply using batteries, rechargeable batteries, solar or 10.8 V DC to 28.8 V DC with integrated UMTS modem; connection to control center via Tele Control Basic, DNP3, IEC60870-5-104 and SINAUT ST 7 protocols, on-board I/O (8 DI, 4 DQ, 4 AI), configuration and diagnostics per web interface, RJ45 port, mobile communications antenna (GSM/UMTS), Mini SIM card, with adapter Micro SIM card also, GPRS (Multi-slot Class 10), 35 mm DIN rail mounting, TCP/IP, DNP 3, Open VPN-Client.
517Programming and Troubleshooting software for RTUs
518Supply, installation, testing and commissioning ofMNRE approved off GridSolar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS fabricated structure 120 micron hot dip galvanized iron , showing arrangement of panel in available space and installation ofPV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in RCC. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structureandsuitable provision shall be included in tender document.
519Earthing Schedule Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. "B" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
520S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.25mm x 3mm GI strip
521ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. (1 Pair * 0.75SQMM)
522Supply of GSM /GPRSbased data transmitter water meter (woltman pulse output ) Model -AE 09-B SIM 2G Battery power -7.4V battery life 3 yr (data once a day) Input Pulse , 4-20ma From pressure RS485 Display-16*2 LCD Encloser-165*120*65 mm ABS Protection-IP65 Operating tempreature -055 C
523Supply,Installation,Testingandcommissioningofcopperwound Transformers33/0.433KV,ThreePhase,50Hz,DYN11,ONAN type , Standard accessories with off load tap changer(+5% to -10% instepsof2.5%),winding/Top---temperatureriseof45°C/40°C firstfilloil,havingpermissibletotallossvaluesnotexceeding7.5% of the maximum total loss values for 11 KV as per energy efficiency level- 2atbasicInsulation levelconferming to ISS2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014. Transformersdescribedasaboveandasperthefollowing continuous rating
524630 KVA
525750 KVA
526Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating
527200KVA
528250KVA
529315KVA
530160KVA
531400 KVA
532SITC of Air Cooled split Air conditioners (wall mounted @ 2.0 ton) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDUto ODU), copper power cable upto 10 Mtr (IDU to ODU), R- 22 Refrigerant suitablefor 400/230V +10% of 50 Hz 1 /3 AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Energy Rating -5 Star.
533Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV Fixed type VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with ABB make Fix Type VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided.
534Supply,Installation,TestingandCommissiongofindoortypefloor mountedmetalclad,33KVIncomerVCBpanelupto630A equippedwithfollowingswitchgearsandaccessoriesdesigned& testedasperlateststandardi.e.IEC62271-200,suitableforSTC 31.5KA/3andIACA-FLRfor31.5kA/1sec.MakeofHTPanel, Vaccum Interrupter and VCB should be of same make. 33KV/110VoltsPTClass0.5accuracyand100VAburdenwith1No. Voltmeter (0-36 KV), analog type, selector switch for voltmeter andprotectionfuses/MCBforHTmeteringupto36KVonincomer, Ammeter,analogtype,selectorswitchesforammeters, MicroprocessorbasednumericalrelaywithO/L,E/FandS/C protection,Setofdualcoredualratio3CTsofsuitableratiowith secondary1A,15 VAburden and accuracy Class – 0.5 for metering and class 5P10 for protection, Multifunction Meter.
535Supply,Installation,TestingandCommissiongofindoortypefloor mountedmetalclad,33KVBusCouplerVCBpanelupto630A equippedwithfollowingswitchgearsandaccessoriesdesigned& testedasperlateststandardi.e.IEC62271-200,suitableforSTC 31.5KA/3 and Internal Arc test A-FLR for full short circuit current for 1sec.duration.MakeofHTPanel,VaccumIntrrupterandVCB should be of same Make. Bus Coupler 1 No 630 Amp. VCB
536Supply,Installation,TestingandCommissiongofindoortypefloor mountedmetalclad,33KVoutgoingVCBpanelupto630A equippedwithfollowingswitchgearsandaccessoriesdesigned& testedasperlateststandardi.e.IEC62271-200,suitableforSTC 31.5KA/3andIACA-FLRfor31.5kA/1sec.MakeofHTPanel, Vaccum Interrupter and VCB should be of same make. 3KV/110VoltsPTClass0.5accuracyand100VAburdenwith1No. Voltmeter (0-36 KV), analog type, selector switch for voltmeter andprotectionfuses/MCBforHTmeteringupto36KV,Ammeter, analog type, selector switches forammeters, Microprocessor based numericalrelaywithO/L,E/FandS/Cprotection,Setofdualcore dualratio3CTsofsuitablerationwithsec1of15VAburdenand accuracyClass–0.5formeteringandclass5P10forprotection, Multifunction Meter
537SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating:
538110VDC
539SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%,50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlasrequired of following rating:
54025 A + 25 A
541Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. "B" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
542Earthing Schedule Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. "B" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
543GI Pipe, Class B, 40mm Dai with thickness of 3.610mm as per IS 1239 for the complete earthing system
544S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.
54550mm x 6mm copper strip
54650mm x 6mm G.I. Strip
54732mm x6mm G.I. Strip
54825mm x 6mm G.I. Strip
549Providing&LayingXLPEinsulatedIS:7098/II/85of approved make H.T.cable for working voltage 33 K.V.Un EarthedwithStrandedCompactedCircularAluminium Conductor,ConductorScreenedwithExtrudedSemi-conductingcompound,XLPEInsulated,Insulation Screenedwithextrudedsemi-conductingcompoundin combinationwithCopperTape,coreslaidup,inner sheathofThermoplastictape,galvanisedflatsteelstrip armouredandoverallExtrudedPVCTypeST-2Outer Sheathedcable direct in ground including excavation of 30cmx150cmsizetrench,25cmlayerofriversand, second Class bricks covering, refilling earth, compaction ofearth,makingnecessaryconnectiontestingetc.as required of size.
5503 core 240.0 Sq.mm
551Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPE insulated33KVcable,withrequiredcomponents,preprationof cable ends, testing etc. as required of following sizes.
552Indoor
5533 core 240/300 /400 Sq.mm
554Outdoor
5553 core 240/300 /400 Sq.mm
556Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge.
557400 SQMM,3.5 core
558300 SQMM,3.5 core
559240 SQMM,3.5 core
56025 SQMM, 3 CORE
56195 SQMM, 3 CORE
562150 SQMM, 3 CORE
56335 SQMM, 3 CORE
56450 SQMM, 3 CORE
56510 SQMM, 3 CORE
56616 SQMM, 3 CORE
567185 SQMM, 3 CORE
568150 SQMM,3.5 core
56970 SQMM, 3 CORE
570120 SQMM, 3 CORE
5714.0 Sq.mm x 3 Core
572Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required.
573Hot Dipped Galvanized
574450mm x 50mm x 2.0mm
575600mm x 50mm x 2.0mm
576Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required.
577Hot Dipped Galvanized
578100mm x 50mm x 1.6mm
579150mm x 50mm x 1.6mm
580300mm x 50mm x 1.6mm
581450mm x 50mm x 2.0mm
582Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR as per latest IS 1562 :2006., 33 KV, 3 mm thick with proof voltage 36 KV / 3 min. and Break Down Voltage 65 KV
583415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalcompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc.
584Incommerfeeder(drowouttype)fortransformer630A/800A,50KA, ACB3pole,AlBusBars,DigitalMultifunctionmetercompatableto SCADA,metering,ProtectionCT"s,IDMT3-O/C&1-E/F,indicating lamps,controlfuse,wiringetc.completeinallrespectofthesize appxo 900(D)X.2400(H)X1000(D)
585Incommer feeder for (drowout type ) transformer 1000A, 50KA, ACB 3pole,AlBusBars,DigitalMultifunctionmetercompatableto SCADA,metering,ProtectionCT"s,IDMT3-O/C&1-E/F,indicating lamps,controlfuse,wiringetc.completeinallrespectofthesize appxo 900(D)X.2400(H)X1000(D)
586Incommerfeederfor(drowouttype)transformer1250A,50KA, ACB3pole,AlBusBars,DigitalMultifunctionmetercompatableto SCADA,metering,ProtectionCT"s,IDMT3-O/C&1-E/F,indicating lamps,controlfuse,wiringetc.completeinallrespectofthesize appxo 900(D)X.2400(H)X1000(D)
587BusCouplerFeeder(drowouttype),1250AACB,50KA,3Pole withoutreleasewithAlBusBars,IndicatingLamps,ControlFusesandwiringetc.completeinallrespect.Size:900(W)x2400(H)x 1000 (D)
588Bus Coupler Feeder (drowout type ), 630/800 A ACB, 50KA, 3 Pole withoutreleasewithAlBusBars,IndicatingLamps,ControlFuses andwiringetc.completeinallrespect.Size:900(W)x2400(H)x 1000 (D)
589BusCouplerFeeder(drowouttype),1000AACB,50KA,3Pole withoutreleasewithAlBusBars,IndicatingLamps,ControlFuses andwiringetc.completeinallrespect.Size:900(W)x2400(H)x 1000 (D)
590250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D)
591400 A MCCB Incomer (Fixed type )with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D)
592630AMCCB(Fixedtype)asoutgoingCT"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)X900(H)X1000(D)
593250AMCCB(Fixedtype)asoutgoingCT"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)600(H)X1000(D)
594MCCB up to 100A(Fixed type ) as outgoing CT"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D)
595400AMCCB(Fixedtype)asoutgoingCT"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)X900(H)X1000(D)
596From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D)
597SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus.
59822KW
59930KW
60037KW
60145KW
60255KW
60375KW
60490KW
605125KW
606433V APFC Panel( 250KVAR) in cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge.
607SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried.
608Local Push Button Station
609SupplyanderectionofOctagonalpoleoffollowing lengthand dimensionas per table-3 withbaseplateon thecementconcretefoundationofM-15/M-20grade (1:1.5:3)withthehelpofanchorboltsofgrade6.8(IS 1367PIII).ThepoleshallbemadeofS-355JOgrade steelsheet,foldedlengthwisetoobtainedOctagonal shape,havingsinglelongitudinalseamweldandhot dippedgalvanisedinternally&externallyinaccordance withIS2629.Thepoleshallhaveaweatherproofflush doorandlockingarrangements.Thecompletework shallbesupervisedandcertifiedbythemanufacturers forsatisfactorysupply,erection,testingand commissioning.
6107 Mtr.
611Supply,ErectionandFixingofhotdippedgalvanised Overhang (60 X 3.25 mm) with cap (250 x 137.9 x 4.05 mm) over the poles
612Single arm overhang
613P/FIP-65/IP-66protectedstreetlightluminarieson bracket / Arm.Fixturemadefrompowdercoated singlepiecepressurediecastaluminumhousingwith heat dissipation fins on housing with high power LEDs . Diffuser/glasscoverforensuringIP-65protectionfor lampandcontrolgearcompartment,systemlumen outputof100lum/watthighpowerLED.Integrated drivershallbehighefficiencyhavingefficiencymore than 85 % and in compliance to IEC standards. System lifeof50000burninghourswith70%ofinitiallumens maintained. Fixture shall be in CE compliance. IP-65 protected LED street light luminaries
614LED street light fixture 80-90 watt
615P&FIP-65protectedintegralfloodlightluminaire suitableforHPSV/Metalhalidelampcomprisingof powdercoateddiecastaluminiumhousing, electrochemicallybrightenedandanodizedstippled aluminium reflector, covered with suitably gasketed heat resistant and toughened glass, porcelain holder, integral controlgearboxhavingcopperballast,capacitor, electronicignitorprewiredwithpvcinsulatedcopper conductoruptoterminalblockincludingmaking connection testing etc.
6161 X 250 Watt
617P&FHighpressuresodiumvapour/Highpressure mercuryvapour/Metalhalide/Halogenlampas required. HPSV tubular lamp normal output.
618250 Watt
619Supply, erection testing and commissioning of high mast lightingsystem(asperCP3-TRT/1996ofILE,UK) consistingoftotallyhotdipgalvanisedbysingledipped method high mast, lantern carriage suitable for up to 12 nosluminaries,mastheadassembly,twonosaviation obstruction neon lights, double drum type self sustaining winch,integralpowertool(winchmotorwithcontrol circuit) hot dipped galvanised heavy duty pipe lightening finial,suitableropesandCCfoundationofM-15grade complete as required. The mast is constructed from mild steelplates(asperBS-EN10025)cutandfoldedto form a polygonal section, telescopic jointed and welding as per BS 5135. The complete work shall be supervised andcertifiedbythemanufacturersforsatisfactory supply,erection,testingandcommissioningofhigh mast.withallaccessories,whichalsoincludsinternal electricalcableandpanelwithfoundation.
62020 Mtr Hm (in 2 section)
621P&FIP-65protectedmultitapballaststreetlight luminaireon bracketsuitableforHPSVLAMP, madeoutfrompowdercoatedsinglepiecediecast aluminiumhousing,electrochemicallybrightenedand anodized POToptics aluminium reflector, heat resistant andtoughenedglasscoverandaccessorieslikemulti tapcopperballast,electronicignitor,capacitor,holder prewireduptoterminalblocketc.asrequiredincluding makingconnectiontestingetc.
6221 X 250/ 150 Watt
623Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer.
624Supply , Installation, Testing and Comissioning of 11 KV, 630 A, 20kA / 3 sec, Out door, Extensible type Ring main unit (RMU) in suitable RCC foundation with 2 no. Load break switch & 1 no. VCB / SF6 circuit breaker with over load, Earth fault, short circuit relay, copper bus bar, earthing switch, mechanical ON / OFF / Earth indication, Voltage presence indicator, Ring core protection CT 2.5 VA, 10P10 as per transformer rating, Shunt trip coil, Anti reflex operating handle, right angle boots etc. OEM Must have BIS certificate and & shall have submitNABL / CPRI / ERDAlab typetest reportsbefore executionas required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
625Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conducting compoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size.
6263 core 120.0 Sq.mm
627Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes .
628Indoor
6293 core 120/150/185 Sq.mm
630Outdoor
6313 core 120/150/185/225 Sq.mm
632S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ControlMCBwithpanelwithallaccessorieswithfollowing rating
6339.3KW
63411KW
63515KW
63618.5KW
637Supply, receving, storing,inspection, handling , assembilng ,installing in correct alligned position, effecting proper connections,testing and commissioning of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories with off load tap changer(+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 450/400 C first fill oil, having permissible totak less values not exceeding 7.5% of the maximum total loss values for 11KVasperenergyefficiencylevel-2atbasicInsulationlevel conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014.
638Transformersdescribedasaboveandasperthefollowing continuous rating
6391250KVA
640Supply , Installation, Testing and Comissioning of Outdoor / Inddor TypeIC-OG 33 KV, 630A, 26.3 KA / 1 Sec. 33KV HT VCB Panel with AL. Bus bar. comprising of 33KV Draw out VCB,630A, 26.3 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (IC-OG). Suitable for Indoor & Outdoor Application (IP 5X).Panel with ABB make VCB, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (600 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible.
641Supply installation testing& Commissioning of star ratedCopper wound distribution Transformer ( All the distribution transformer must bestarratedaspernotificationof(BEE)ministryofpower, GoverenmentofIndia)offollowingrating11/0.433KVDelta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & lossesas defined as perIS1180partI2014.includingstandardaccessorieslike conservator,silicagelbreather,Bucholzrelay,radiator,fins,HT cablebox<cableboxes,Off-LTC(+5%to-10%@2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding , ISI markeddrainvalve,DialtypeTemperaturegauge,firstfillingof transformer oil as per IS :335-1953 , Epoxy based paint,including carryingofpre-commissionTesting&ChargingofTransformer completeinallrespect.NABLaccredeated/CPRI/ERDAlab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricityrule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
64263KVA
643400KVA
644500KVA
645Supply,Installation,TestingandComissioningof11KV,630A, 20kA / 3 sec, Out door,Extensible type Ring main unit (RMU) in suitable RCC foundation with 2 no. Load break switch & 1 no. VCB / SF6circuitbreakerwithoverload,Earthfault,shortcircuitrelay, copperbusbar,earthingswitch,mechanicalON/OFF/Earth indication, Voltage presence indicator, Ring core protection CT 2.5 VA,10P10aspertransformerrating,Shunttripcoil,Antireflexoperatinghandle,rightanglebootsetc.OEMMusthaveBIS certificate and&shall have submitNABL / CPRI / ERDAlab typetest reportsbefore execution as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
646Plate Earthing as per PWD specification for electrical Works as per IS:3043 withcopper Earth plate of size 600mm x 600mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. "B" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
647Plate Earthing as per PWD specification for electrical Works as per IS:3043 withcopper Earth plate of size 300mm x 300mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. "B" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
648G.I. pipe 50 mm dia as per IS:1239FOR EARTHING SYSTEM
649Supply & Laying following size earth stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm makingconnectionetc.asrequired.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
65050mm x 6mm copper strip
65150mm x 6mm G.I. ( Hot Dipped) Strip
65232mm x6mm G.I. ( Hot Dipped) Strip
65325mm x 6mm G.I. ( Hot Dipped) Strip
654Providing & Laying XLPE insulated as per IS:7098/II/85H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E)inexistingRCC/Hume/Stoneware/PVCpipe/open duct/cabletrenchwithfillingofexcavatedearthintrench,on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size as per points (a), (b), (c) mentioned below:-(a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I (b)conductorshallhaveelectrolyticaluminiumconfirmingtoIS 8130, IS 3975-1999for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c)OEMMusthaveISO9001&14001certificationsforquality assuarance&itsowninhouseNABLlabsetupforalltesting facilities forcables .All above as per pre approved by Engineer in charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR .
6553 core 120.0 Sq.mm
656Providing & Laying XLPE insulated as per IS:7098/II/85H.T.cable as per PWD specification for electrical Works for working voltage 33 K.V.(E)inexistingRCC/Hume/Stoneware/PVCpipe/open duct/cabletrenchwithfillingofexcavatedearthintrench,on existing cable trays or on surface etc.including making necessary connection, testing etc.as required of size as per points (a), (b), (c) mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I (b)conductorshallhaveelectrolyticaluminiumconfirmingtoIS 8130, IS 3975-1999for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c)OEMMusthaveISO9001&14001certificationsforquality assuarance&itsowninhouseNABLlabsetupforalltesting facilities forcables .All above as per pre approved by Engineer in charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR .
6573 core 185.0 Sq.mm
658Providing&makingheatshrinkabletypeindoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for11 KV / 33 KV cable with required components, preprationofcableends.Typetestreportshouldbeasper IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streightthrough joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Crosslinking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge includingtesting etc. as required of following sizes. All as per pre approved by Engineer in charge.For additional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR .
65911 KV End Termination Kit Indoor type
6603 core 120/150/185 Sq.mm
66111 KV End Termination Kit Outdoor type
6623 core 120/150/185 Sq.mm
66333 KV End Termination Kit Indoor type
6643 core185/240 Sq.mm
66533 KV End Termination Kit Outdoor type
6663 core185/240 Sq.mm
667Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured/Armouredaluminiumcableof1.1KVgradeasper PWD specification for electrical Worksin existing RCC / Hume / Stoneware/PVCpipe/openduct/cabletrenchwithfillingof excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:-(a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P – I (b)conductorshallhaveelectrolyticaluminiumconfirmingtoIS 8130,IS3975-1999forarmouringofcablesinarmouredcable items,IS5831forsheath,IS10810(Part0to64)fortesting procedures. (c)OEMMusthaveISO9001&14001certificationsforquality assuarance&itsowninhouseNABLlabsetupforalltesting facilitiesforcables.Appropriatetypetestcertificate/OEMtest reportshallbesubmitted.Allaboveasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR.
668Armoured Cable
669400 SQMM,3.5 CORE
670300 SQMM,3.5 CORE
67125 SQMM, 3 CORE
67250 SQMM, 3 CORE
673120 SQMM, 3 CORE
674185 SQMM, 3 CORE
67570 SQMM, 3 CORE
67695 SQMM, 3 CORE
67716 SQMM, 3 CORE
67850 SQMM,3.5 CORE
67910 SQMM, 3 CORE
6804.0 SQMM, 3 CORE
681Supply,Fabricating&installingfollowingsizesofpowdercoatedladder type M.S. cable trays with rungs at span of 250 mm including horizontalandverticalbends,reducerstees,crossmembersand otheraccessoriesasrequiredanddulysuspendedfromthe ceiling/wallwithMSsuspendersincludingbolts&nuts,fastners, supports,paintingsuspendersetc.asrequired.Allasperpre approvedbyEngineerincharge.Foradditionaltechnical parameters of products/ work, refer Annexure "A" attached with this BSR .
682450mm x 50mm x 2.0mm
683600mm x 50mm x 2.0mm
684Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross membersandotheraccessoriesasrequiredanddulysuspended fromtheceilingwithGIsuspendersincludingGIbolts&nuts, fastners,supportsetc.asrequired.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
685100mm x 50mm x 1.6mm
686150mm x 50mm x 1.6mm
687300mm x 50mm x 1.6mm
688450mm x 50mm x 2.0mm
689Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
69011 KV,2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV
691SITC of floor mounted drowout type PMCC (Indoor, Dury, dust proff IP-4xfrontoperatedwith2mmthicksheetmetal compartmentalised)withallaccessibleparts,headshrinkable sleeves, SMC/DMC bus bar supports, padlocking facility on outgoing feeders etc.
692Incommerfeederfortransformer630A/800A,50KA,ACB3pole,Al BusBars,DigitalMultifunctionmetercompatabletoSCADA, metering,ProtectionCT"s,IDMT3O/C&1E/F,indicating lamps,controlfuse,wiringetc.completeinallrespectofthesize appxo 900(D)X.2400(H)X1000(D)
693Bus Coupler Feeder, 630/800 A ACB ,50KA,3 Pole without release with Al Bus Bars, Protection CT"s ,IDMT 3 O/C & 1 E/F,Indicating Lamps,Control Fses and wiring etc.complete in all respect. (Size : 900(W) x 2400 (H) x 1000 (D)
694Incommer feeder for transformer 1600 A,50KA,ACB 3 pole,Al Bus Bars,DigitalMultifunctionmetercompatableto SCADA,metering,ProtectionCT"s,IDMT3O/C&1E/F,indicating lamps,controlfuse,wiringetc.completeinallrespectofthesize appxo 900(D)X.2400(H)X1000(D)
695Bus Coupler Feeder, 1600 A ACB,50KA, 3 Pole without release with AlBusBars,ProtectionCT"s,IDMT3O/C&1E/F,Indicating Lamps,Control Fses and wiring etc.complete in all respect. (Size : 900(W) x 2400 (H) x 1000 (D)
696250AMCCBIncomerwithmeteringCTs,multifuctionmeter compatibletoscada,AmpermeterwithSS,Voltmeterwith SS,Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:900(W)X2400(H)X1000(D)
697MCCB up to 100Aas outing CT"s,Ampermeter with SS,Voltmeter withSS,IndicatingLamps,ControlFuse,wiringetc.completeinall respect. Size:600(W)X2400(H)X1000(D)
698250 A MCCB as outgoing CT"s,Ampermeter with SS,Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinall respect. Size:900(W)X2400(H)X1000(D)
699400AMCCBIncomerwithMeeteringCT"s,multifuctionmeter compatibletoscada,AmpermeterwithSS,Voltmeterwith SS,Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:900(W)X2400(H)X1000(D)
700S & F of Star delta Starter with MCB, Main and Aux Contactor, O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button ,Control MCB with panel with all accessorieswith following rating
7017.5 KW to 9.3KW
702SITC ofDraw out type 3/4 pole IP53, IK 08 door interlock Air Circuit Breaker(ACB)asperPWDspecificationforelectricalWorks, conforming to IS/IEC 60947 P - 2 :2003 in existingLT panel suitable for LT installation 440 V, 50 Hz and havingadjustable over load short-circuit, earth fault and withseparate LED indication for each type of fault ,Password protected relase (trip mechanisum) shall confirm to EMI/ EMC test , LCD/LEDdisplay , Thermal memory , pollution degree 4, trip free mechanisum , suitable for ambient 50 degree and utilization catagary B.In built electrical & mechanical anti pumping fearute , 100% rated neutral . ACB shall have separate indicationforservice,test,isolation&maintenanceposition, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break timenotmorethen25ms.Provisionforelectrical&mechanical interlock between ACBs, Min.electricaloperation 10,000 upto 2000 A rating and 5,000 for2500 A. including making connectionsetc. asrequired.OEMshallhavesubmitNABL/CPRI/ERDA accrediated lab type test certificate before execution & All as per preapprovedbyEngineerincharge.Foradditionaltechnical parameters of products/ work, refer Annexure "A" attached with this BSR .
703Microprocessor based release Draw out type ( Motorised charging type ) 3Pole
704800 A Rating, 50kA
705SupplyandfixingoffollowingaccessoriesforAircircuitbreaker (ACB)compatible with MAin ACB OEM as per PWD specification forelectricalWorks,conformingtoIS/IEC60947P-2:2003 including making connection etc complete in all respect. OEM shall havesubmitNABL/CPRI/ERDAaccrediatedlabtypetest certificate before execution . All as per pre approved by Engineer in charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR .
706Shunt Trip Release
707Under Voltage Release
708Earth Fault Release
709Providing& Fixingof selfhealing IP20MPP type shunt capacitor (banks) as per PWD specification for electrical Works, ISI marked IS:13340-41 / conforming to IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.35 Watt per KVAR. Min over current capacity1.8timesratedcurrent&peakinrushcurrentmin.250 times of rated current,including making connections, testing etc. as required.AllasperpreapprovedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
710Heavy dutyThree phase 480 V, 50 Hzcylindrical capacitor (Bank)
711Providing&FixingofIP54onfrontmicroprocessorbasedthree phase sensingpower factor correction relay , IEC / EN 61000-6-(2&4)having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status,alarmoutputforundercurrent,overcurrent,insufficient compensation, communication interface with RS 485,indication of switchingonunits,auto/manualstatus,andshallhaveoverload protection, no volt release , having multi parameter like KW, KVA, KVAR, VTHD, ITHD,metering facility as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reports.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
71212 to 14 stage
713Providing & Fixing ofISO certified company madeCam operated rotary (Auto/manual) switches on existing panel with 2 way and off positionusinghighgradeengineeringmaterialtointernational standards with cam assemblyinsulation of glass filled polyamide withhightrackingindex.Forreliableandstableelectricaland mechanical endurance double butt contacts with silver bi-metal on coppershouldprovided.contactassemblyisofoperatingtemp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc.as required . All as per pre approved by Engineer in charge.Foradditionaltechnicalparametersofproducts/work,refer Annexure "A" attached with this BSR .
71410 AMP
715Providing& Fixingof440 Volt 3pole capacitor(AC 6B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works,IS/IEC 60947-4-1:2000,insulationvoltage1000V,impulsewithstand voltage 8 KV,Din rail mounting type including making connections, testingetc.asrequired.suitableforfollowingcapacitycapacitor bank. All as per pre approved by Engineer in charge.For additional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR .
716up to 6 KVAR
71710KVAR
71825KVAR
71950KVAR
720SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, displayof electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.
72122KW
72245KW
72355KW
72475KW
72590KW
726110KW
727160KW
728S & F of Star delta Starter with MCB, Main and Aux Contactor, O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button ,Control MCB with panel with all accessorieswith following rating
72915KW
73018.5KW
731433V APFC Panel in cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge.
732433VIndoor LT Switchgear Panel for POST CHLORINATION SYSTEM in cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor PCC panel switches gear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based relays, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge.
733SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried.
734Octagonal MS Polesmade of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seamweldandhotdippedgalvanisedinternally&externallyin accordance with IS 2629. (See Table P -01 for specs.)
7357 Mtr.
736Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
737Single arm overhang
738Providing&FixingofIK07IP66protectedLEDStreetLight Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glasscover(UVstablzationreportsubmittedforUVcover)and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wtwith High Power LEDs is to be usedandpotteddrivermustbepotted&hasauniqueBISR number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 VAC and Auto resettingSafety ,InputFrequency 50Hz±3%PowerFactor>0.95driverEfficiency>85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <1000mA shown in LM79 report. The luminaireshall be BIS certifiedandT.C.certified.LifeExpectancyEqualormorethan 50000burninghrswithMinimum70%lumenmaintened,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min = 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/NameEngraved/Embossingondiecasthousingtoallow traceability/authenticity.FixtureshallbeASPERIS10322 Complianced. OEMMusthaveitsowninhouseNABLlabsetupforalltesting facilities forLED fixtures.(LM79/LM80) Certificate/ reportwith liable warranty of product/accessories from OEM shall be submitted.AllasperpreapprovedbyEngineerincharge.Foradditional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR .
739LED Street Light fixture 100 Watt
740Providing&FixingofthermoplasticPolycarbonatecablejunction boxes with IP66 rating of protection & knock out for cable entry/out of following sizes including clamps for holding the box, including cost of DIN rail for MCB mounting, 10 Sqmm 4 pole connectors for cables terminals,threaded cable glands made of polyamide material etc. completeinallrespect.AllasperpreapprovedbyEngineerin charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR .
741175mm X 150mm X100mm
742Providing & Fixing of Street light bracket made out from following size of " B " class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
74332 mm Dia.
744Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as pertypeofloadandsiterequirement)4KVimpulsewithstand voltage,asperPWDspecificationforelectricalWorkswithISI markedIS8828(1996)/conformingtoIEC60898-12002,IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass3asperIEC,minimumphaseterminationcapacityof 35sq.mm. , conductorline load reversibility, label holding facility , IP 20contactprotectionandfittedwithexistingdistribution board/sheets,min.operation20,000upto32Aratingand10,000 upto63A,5000for80Aratingincludingmakingconnections, testing etc. as required.. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per preapprovedbyEngineerincharge.Foradditionaltechnical parameters of products/ work, refer Annexure "A" attached with this BSR .
745Double pole MCB
7466 A to 32 A rating
747Supply,Installation,TestingandComissioningofISOcertified company made Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete withIndoorunit(IDU),Outdoorunit(ODU),surface/concealed copperRefrigerantpipingwithinsulation(closedcellelastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and50 hz ,1 phaseACsupplycapableofperformingcooling,dehumidification,air circulation of following capacity with Scroll / rotary compressor. Min 5 year OEM warranty both compressor and PCB.NABLaccredeatedasperIS/ISO/IEC17025standards/CPRI/ ERDAlabtestingreportsasperIS1391(Part-2)2018withOEM certificatemustsubmittedtoengineerincharge.Allasperpre approvedbyEngineerincharge.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
748Invertor Type
7491.8/2.0 TR with 5 star rating of BEE (ISEER not less then 4.5 )
750Supply&FixingofFRPVCinsulated&sheathed3coreflexible copperconductorasperPWDspecificationforelectricalWorksconfirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from99.99% purity copper, class 5 stranding in acc. to IEC 60228 forlower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity,insulationPVCtypeA,flameretardantasperIS 10810-53, better amperage rating as per VDE 0298 part 4 including makingconnectionetc.asrequired.OEMMusthaveitsownin house NABL lab setup for all testing facilities for wires. All as per pre approvedbyEngineerincharge,makingconnections.For additional technical parameters of products/ work, referAnnexure "A" attached with this BSR .
7516.0 Sq.mm
752Supplyandinstallationof UL listed,CPRI tested copper bounded steelelectrode of minimum 17.2 mm dia. (as per IEC 62561-2 ) With a minimum coating thickness of 250 micronsandlength of 3 meters, filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends as per point mentioned (a), (b), [c), (d), (e) below :- (a)filledwithanticorrosiveconductivecompoundswiththe permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 35- 40 KA for withstanding 1 second .(b) To ensure the moisture content and electrical conductivity, 25 kg for2000mm&50Kgsfor3000mmofresistanceloweringearth enhancement material shall be used as a backfill compound. The compoundshallbetestedformNABLacredeatedlabforlowresistivity(lessthan0.12Ohm-meter)&highconductivityin nature with carbon as a major contentas per referance of IS 3043-1987,IEEE80-2013(clause14.5d),IEEE837&IER1956with latest amendemnts (c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. (d)Testingofearthresistanceforvalueof5ohmsorlessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e)SelfcertificateforconfirmingabovestandardsfromOEMis mandatory.AllasperpreapprovedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
753Providing&Fixingofcoppertape20mmx3mmonparapetor surface of wall fixed with porcelain or bakelite insulator (SP-35) in vertical/horizontalrunasrequired.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
75420mm x 3mm copper strip
755Mesh earthing as per IS:3043 with copper earth strip of size 20 mm x 3 mm to form a mesh of size 3000 mm x 1000 mm in horizontal formation to create equal sections of 500 mm x 500 mm by means of 10 mm brass bolts, & nuts with spring washer, embodying 1 mtr. Belowthegroundlevel,refillingthepitbyalternativelayersof charcoal & salt up to 500 mm with 20 mm dia, 20mm GI "B" class wateringpipeand12mmGI"B"classpipefortheearthwire including all accessories like nuts, bolts, wire mesh funnel and brick masonaryfinishedchambercoveredwithhingedCIcoverand lockingarrangementofsize300mmx300mmcompleteinall respect.
756Providing & Fixing ofIK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps.Integrateddrivermustbepotted&hasauniqueBISR number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wtwith High Power LEDs is to be used.LEDdriverInputVoltageAC120to270VACwithHigh voltageCutoff@>=300VACandAutoresettingSafety.Input Frequency 50Hz±3%, Power Factor >0.95 ,driverEfficiency >85% , THD(I) <10%, driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of InitialLumensmaintained,colorRenderingIndex>70andCCT 5700K±355K.Drivercurrent<1000mAshowninLM79report. ManufacturesWordMark/NameEngraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced. OEMMusthaveitsowninhouseNABLlabsetupforalltesting facilities forLED fixtures.(LM79/LM80) Certificate/ reportwith liable warranty of product/accessories from OEM shall be submitted. AllasperpreapprovedbyEngineerincharge.Foradditional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR .
757High Power LED Flood Light 100W
758From 3.3 KW to 7.5 KW DOL Starter Feeder with MCB, Main and Aux Contactor, O/L Relay, L/R Selector Switch,3 Indicating lamps, Start-Stop Push Button ,Control MCB(Size : 600 (W) x 400 (H) x 600 (D)
759Design,Manufacture,Supply,Installation,Testingand Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheetcompletewithlatestconfiguration,necessaryprogramming software for PLC & SCADA and comprising of all accessories not limited to the following: DI No.30 DO No.26 AI No.6 AO No.2 MCB 16A DP No.2 MCB 6A DPNo.6 SMPS 100-240VAC/ 4.5A / 24 VDC No.1 Selector Switch (Auto/Manual) & Local / RemoteNo.2 Control RelaysLot1 Annunciatorwith24WindowsNOtoNCType Microprocessor Based, WindowSize 75*42mm, 110VAC, with No.1 Electronic HooterNo.1 Control Transformer 200VANo.1 Emergency STOP Push ButtonNo.1 Panel Cooling Fan & FilterNo.2 Panel Light with Door Switch, 7WNo.1 Control Indication Lamp for 24VDC, 220VACNo.3 Push ButtonNo.3 Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc Lot1 PanelHardware,lugs,terminations,ferrules, name plate Etc. Lot1 UTILITY SOCKET 16A, 3 PINNo.2 HMI Display 10 Inch, ColourNo.1 Isolators Dual Output, 24VDCLot1
760Design,Manufacture,Supply,Installation,Testingand Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheetcompletewithlatestconfiguration,necessaryprogramming software for PLC & SCADA and comprising of all accessories not limited to the following: DI No.102 DO No.98 AI No.22 AO No.16 MCB 16A DP No.2 MCB 6A DPNo.6 SMPS 100-240VAC/ 4.5A / 24 VDC No.1 Selector Switch (Auto/Manual) & Local / RemoteNo.2 Control RelaysLot1 Annunciatorwith24WindowsNOtoNCType Microprocessor Based, WindowSize 75*42mm, 110VAC, with Electronic HooterNo.1 Control Transformer 200VANo.1 Emergency STOP Push ButtonNo.1 Panel Cooling Fan & FilterNo.2 Panel Light with Door Switch, 7WNo.1 Control Indication Lamp for 24VDC, 220VACNo.3 Push ButtonNo.3 Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc Lot1 panelHardware,lugs,terminations,ferrules, name plate Etc. Lot1 UTILITY SOCKET 16A, 3 PINNo.2 HMI Display 12 Inch, ColourNo.1 Isolators Dual Output, 24VDCLot1
761Modular RTU complete with DI, DO, AI and modbus communication ports and power supply 24 VDC or for variable power supply using batteries, rechargeable batteries, solar or 10.8 V DC to 28.8 V DC with integrated modem; connection to control center via Tele Control Basic,DNP3,IEC60870-5-104andCommunicationprotocols,on-board I/Os min. (8 DI, 4 DQ, 2 AI), configuration and diagnostics per webinterface,RJ45port,mobilecommunicationsantenna (GSM/UMTS),MiniSIMcard,withadapterMicroSIMcardalso, GPRS (Multi-slot Class 10), 35 mm DIN rail mounting, TCP/IP, DNP 3, Open VPN-Client. Panel Enclosure for Compact RTU Location, wall/floormountedalongwithwiringandrelatedaccessoriesand arrangement of mounting of RTU, Modem having IP-5X Protection. Panels shall be self-fabricate type only with Canopy.
762SITCofIntelligentManageableEthernetSwitchesproviding24x 10/100/1000FastEthernetports-and2dualpurposeuplink (provisionforCopper/FibreGigaconnectivity)withLANbased Software.TheLANbasedS/Wsupportsenhancedintegrated security,includingNetworkAdmissionControl(NAC),advanced qualityofservice(QoS),availabilityandscalablemanagementto enable new converged applications
7634G/3G GPRS VPNmodemwithEthernetbridge/ router/ serial server (RS232/485) Interface to MCC Room ( Wireless Gateway)
764Providing, installation, testing and commissioning of ONLINE UPS SYSTEM,SinglePhase230V,50Hzwith2hourbackupSMF battery bank as per specification
7651 KVA
7663KVA
767ProvidingandlayingStranded/FlexibleAnnealedeBarecopper conductor,XLPE/PVCinsulatedsuitablylaiduptogetheroverall polystertapedAl(innersheatedGISteelwireMylar/Drainwire) alongwithATCdrainwire,round/steelarmouredoverallPVC sheathed (ST-1) overall screenedCore armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009.
7681 SQMM
76924 CORE
770ProvidingandlayingStranded/FlexibleAnnealedeBarecopper conductor,XLPE/PVCinsulatedsuitablylaiduptogetheroverall polyster taped Al (Mylar tape wrapped) along with ATC Drain wireoverallPVCsheathed(ST-1)overallscreenedPairarmoured instrumentationCablesgenerallyconfirmingtoPAS5308-Part-2-2009.
7711 SQMM
7721 PAIR
773ProvidingandlayingXLPE/PVCinsulated&PVCsheathed armoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavationj of 30 CmX75 Cm size trench 25 Cm thick under layer of sand and Iind class bricks covering
7746C x 1.5 sq.mm
7754C x 1.5 sq.mm
776Providing,Installation,TestingandCommissioningofUltrasonic Level Transmitter : Principle : Timeof Flight/ Sensor MOC PP / PowerSupply:24VDC/Output:4-20mA/Display:Integral displayfor programming andDisplayReading/ IP 66/ Accuracy ±1%
7770-5M
778Providing,Installation,TestingandCommissioningofPressure Transmitter : Range:0-10Bar / Power Supply:24 V DC / Output: 4-20mA withHART / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67
779Providing,installation,testingandcommissioningofDiaphragm TypePressureGaugesDialsize150mmglycerinefilled shatterproofglass,Overrangeprotection:125%ofmaximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminium
780Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material of sensor and other wetted parts: SS type 316, Housing: Die cast aluminium, Switch type: Microswitch, Repeatability: ± 1% of span, Switch Contacts: 2 NO + 2 NC
781Providing,installation,testingandcommissioningofLevelSwitch (Conductivity) Conductivity Probes, Probe insulation: Teflon, Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminium
782Rigid for lengths ofup to 3 Mtr.
783Providing,installation,testingandcommissioningofCapacitance Level Transmitter for tank /sump level Accuracy: ±1.5 % of span, Probe type: Rod, Probe material: SS type 316, Weather Protection Class:IP65ofIS13947PartI,Output:4-20mADC(Isolated), Material of wetted parts: SS 316, Probe insulation material: Teflon, Stilling pipe: SS type 316 with perforations
784Supply,Installation,TestingandCommissioningofOnline MultichannelandMultiparameterTransmitter/ConverterforLiquid Analysis Sensors as per CPCB/SPCB guidelines.
785Dual Channel (2 Sensor Input)
786Four Channel (4 Sensor Input)
787FRC Sensor Range :- 0.05 to 20 mg/l
788Turbidity SensorRange :- 0-4000 FNU
789pH Sensor Range :- 0-14
790FRC Sensor Range :- 0.05 to 20 mg/l
791Supply, Installation, testing and commissioning of SCADA System at MasterControlCentrecompletewithPCserver,monitor, communication modules, printers, 2 Nos. of 60"LED Display of latest resolution and configuration, 4 Nos of 32"" Operator console ( 1 No. of Engineering, 1 No. of operator console, 1 No. of Historical and 1 No. of Web Server) including control desk, chairs, storage racks etc., requiredhardware,softwarecompletewithallaccessoriesandin line with Technical Specification.
792Providing, installation, testing and commissioning of ONLINE UPS SYSTEM,SinglePhase230V,50Hzwith2hourbackupSMF battery bank as per specification
7935KVA
794Plate Earthing as per PWD specification for electrical Works as per IS:3043 withcopper Earth plate of size 300mm x 300mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. "B" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
795Supply & Laying following size earth stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm makingconnectionetc.asrequired.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
79625mm x 3mm G.I. ( Hot Dipped) Strip
797Supply, installation, testing and commissioning ofMNRE approved off GridSolar Panels with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS fabricated structure 120 micron hot dip galvanized iron , showing arrangement of panel in available space and installation ofPV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in RCC. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structureandsuitable provision shall be included in tender document.
798Supply of GSM /GPRSbased data transmitter for Bulk Flowmeter (woltman Pulse Output only ), Battery Powered -7.4V,battery life 3-5 Years,(1 no Data transmit in aday),4-20mA From Pressure RS485 Display-16*2 LCD,Encloser-165*120*65 mm,ABS Protection-IP65,Operating tempreature -55 Deg. C
799O&M Cost for 10 Years 5.25 % of total cost except Internal distribution network and FHTC
800For the 1st Year of O&M after DLP
801For the 2nd Year of O&M after DLP
802For the 3rd Year of O&M after DLP
803For the 4th Year of O&M after DLP
804For the 5th Year of O&M after DLP
805For the 6th Year of O&M after DLP
806For the 7th Year of O&M after DLP
807For the 8th Year of O&M after DLP
808For the 9th Year of O&M after DLP
809For the 10th Year of O&M after DLP
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2022 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail