Bids Are Invited For Mgps Total Quantity : 1------1 5x2 D type bulk cylinder wall type oxygen manifold fabricated from high pressure non arsenical, `phosphorous, deoxidized degreased seamless round 16mm OD copper pipe having 15 SWG thicknesses conformin

Issued by Statutory Bodies & Commissions/Committees · Nandurbar, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
15 Aug 2022
0 days left
EMD
25000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nandurbar → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Bids Are Invited For Mgps Total Quantity : 1------1 5x2 D type bulk cylinder wall type oxygen manifold fabricated from high pressure non arsenical, `phosphorous, deoxidized degreased seamless round 16mm OD copper pipe having 15 SWG thicknesses conforming to BS:6017:1981 material and manufacturer as per BS:EN :1057:1996. The cylinders should be connected through extruded brass conforming BS 249 and hard soldered slip on tee at every 250mm space. The third side of the tee should have male thread for connecting each cylinder using pig tail pipes. Each male connection of the tee should be connected with high pressure non return valve with spring loaded seat arrangement. The entire manifold top frame should be supported by 50mm x 50mm x 6mm thick steel angle with suitable distance piece at the back so that when the manifold top frame is installed it is 50mm away form the surface of the wall. The cylinders should be connected to the manifold through high pressure coiled half hard copper tail pipe with extruded brass end connections. One end connection of the tail pipe should be suitable for cylinder valve and the other end suitable for top frame NRV connection. The Tail pipe should be half hard seamless 3/8” OD and ¼” bore copper pipe. There should be Indigineous 2 Oxygen Fully Automatic Changeover Control Panel of 2000 lpm It should fully comply and meet with the requirements of the NFPA-99/ISO/HTM. It should be CE marked . and all the regulators should be adiabatic certified. The Manifold Control System should supply any type of medical gas from both left & right hand manifold banks. It should be capable to supply a flow of over 1800 L/min. to a 400 kPa (4 bar) distribution system. Either the left or right hand manifold bank should be designated Duty and the Control Panel should be micro processor controlled and automatically changeover to supply the distribution system from the Standby bank when the pressure in the Duty bank falls to a pre-determined level. Indigineous 3 Surface mounted Oxygen gas Outlet (Front loading BS Type) It should fully complies and meets with the requirements of the NFPA-99 It should be CE marked . Terminal units should have gas indexing geometry to BS 5682:1998. Terminal unit front fascia should be made of metal. Gas specific components comprising the terminal unit second fix should be manufactured from diecast zinc alloy or similar hard wearing metal. Indigineous 4 Oxygen BPC flow meter with humidifier It should be Back Pressure compensated with Durable polycarbonate flow tube with cover. Flow meter should have twin graduated scale which should provide precision control permanent scale graduations. Flow meter should be placed in the vertical position. The flow meters should be of 0-15 LPM range for oxygen and with inlet pressure 50-60psi. Indigineous SPECIFICATION 5 Vacuum System - 3 HP Duplex base mounted vacuum pump each (or more) Medical Vacuum Plant 3 Phase 50 Hz (Package Unit) Fully Compliant to one of the Standards HTM02-01/ NFPA/ DIN standards. The plant should Comprise of base/floor mounted Duplex 5 HP vacuum pumps and one no’s. of 1000 liters capacity vertical vacuum receiver tanks. The Medical Vacuum Plant should be fully tested and a test certificate should be provided showing the results of the tests, including the free-air flow rate obtained at an inlet vacuum of 450 mmHg. Testing in component form is not acceptable. All Vacuum pumps must be air-cooled, oil lubricated type suitable for both continuous and frequent start/stop operation at nominal inlet vacuum levels of between 475 mmHg Indigineous 6 SITC of Vaccum Pump 3 Hp duplex system with receiver Capacity 250 Ltrs and bacteria filters as per HTM standard incl electrical system Indigineous 7 Surface mounted Vacuum Outlet (Front loading BS Type) It should fully complies and meets with the requirements of the NFPA-99 It should be CE marked . Terminal units should have gas indexing geometry to BS 5682:1998. Terminal unit front fascia should be made of metal. Gas specific components comprising the terminal unit second fix should be manufactured from diecast zinc alloy or similar hard wearing metal. Indigineous 8 Ward Vacuum unit with 600 ml jars Vacuum Regulator and a 600ml polycarbonate collection jar with lid and plastic mounting bracket. Indigineous 9 High pressure anti static tubing for Vacuum (yellow) Indigineous 10 Copper Pipes (Medical Grade): Oxygen distribution pipeline shall be suitably designed for connection of hospital wards with Jumbo Cylinder manifold/ Liquid Dura system / PSA Oxygen plant with parallel connection and separate isolation valve. Each hospital ward shall have individual isolation valve from header. The piped distribution system should use copper pipes manufactured from phosphorous de-oxidised non-arsenical copper to BS EN 1412:1996 grade CW024A (Cu-DHP), manufactured to metric outside diameters and having mechanical properties in accordance with BS EN 13348:2008 in either R250 (half hard) or R290 (hard). Degreasing of pipe should be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS EN 13348:2008. As per NHS C11 section 05 the copper tube should have BS kite mark and certificate number (mandatory). Indigineous 10.1 12mm OD medical grade copper pipe Indigineous 10.2 15mm OD medical grade copper pipe Indigineous 10.3 22mm OD medical grade copper pipe Indigineous 10.4 28mm OD medical grade copper pipe Indigineous 11 Isolation valves suitable for Medical Oxygen gas, Brass body Indigineous 11.1 15mm Isolation valve Indigineous 11.2 22mm Isolation valve Indigineous 11.3 28mm Isolation valve Indigineous 12 Gas Alarm panel - It should fully comply and meet the requirements of the NFPA99. It should be capable of monitoring up to 6 gas services by means of pressure sensors that detect deviations from the normal operating limits.. The cover, back box and bezel should be of polyester powder. A single tamperproof fastener should be used to gain access to the hinged door. It should have each gas service displayed by colored LED’s to show ‘Normal’ (green), ‘Low’ and ‘High’ pressure (red) conditions. Medical vacuum systems should be displayed in the ‘Normal’ (green) and ‘Low’ vacuum (red) conditions. Failure indicators should be displayed by flashing lights and normal indications should be steady. Each LED block indicator should be a plug-in component with individual long life LED’s connected in parallel in two banks to provide duplex circuits. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided. Indigineous 12.1 Area alarm panel for 2 gas service. Indigineous

AI Tender Summary

OUR REF NO 33406974
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 15-08-2022
Authority
Authority Name Public Health And Family Welfare
Work Description Bids Are Invited For Mgps Total Quantity : 1------1 5x2 D type bulk cylinder wall type oxygen manifold fabricated from high pressure non arsenical, `phosphorous, deoxidized degreased seamless round 16mm OD copper pipe having 15 SWG thicknesses conforming to BS:6017:1981 material and manufacturer as per BS:EN :1057:1996. The cylinders should be connected through extruded brass conforming BS 249 and hard soldered slip on tee at every 250mm space. The third side of the tee should have male thread for connecting each cylinder using pig tail pipes. Each male connection of the tee should be connected with high pressure non return valve with spring loaded seat arrangement. The entire manifold top frame should be supported by 50mm x 50mm x 6mm thick steel angle with suitable distance piece at the back so that when the manifold top frame is installed it is 50mm away form the surface of the wall. The cylinders should be connected to the manifold through high pressure coiled half hard copper tail pipe with extruded brass end connections. One end connection of the tail pipe should be suitable for cylinder valve and the other end suitable for top frame NRV connection. The Tail pipe should be half hard seamless 3/8” OD and ¼” bore copper pipe. There should be Indigineous 2 Oxygen Fully Automatic Changeover Control Panel of 2000 lpm It should fully comply and meet with the requirements of the NFPA-99/ISO/HTM. It should be CE marked . and all the regulators should be adiabatic certified. The Manifold Control System should supply any type of medical gas from both left & right hand manifold banks. It should be capable to supply a flow of over 1800 L/min. to a 400 kPa (4 bar) distribution system. Either the left or right hand manifold bank should be designated Duty and the Control Panel should be micro processor controlled and automatically changeover to supply the distribution system from the Standby bank when the pressure in the Duty bank falls to a pre-determined level. Indigineous 3 Surface mounted Oxygen gas Outlet (Front loading BS Type) It should fully complies and meets with the requirements of the NFPA-99 It should be CE marked . Terminal units should have gas indexing geometry to BS 5682:1998. Terminal unit front fascia should be made of metal. Gas specific components comprising the terminal unit second fix should be manufactured from diecast zinc alloy or similar hard wearing metal. Indigineous 4 Oxygen BPC flow meter with humidifier It should be Back Pressure compensated with Durable polycarbonate flow tube with cover. Flow meter should have twin graduated scale which should provide precision control permanent scale graduations. Flow meter should be placed in the vertical position. The flow meters should be of 0-15 LPM range for oxygen and with inlet pressure 50-60psi. Indigineous SPECIFICATION 5 Vacuum System - 3 HP Duplex base mounted vacuum pump each (or more) Medical Vacuum Plant 3 Phase 50 Hz (Package Unit) Fully Compliant to one of the Standards HTM02-01/ NFPA/ DIN standards. The plant should Comprise of base/floor mounted Duplex 5 HP vacuum pumps and one no’s. of 1000 liters capacity vertical vacuum receiver tanks. The Medical Vacuum Plant should be fully tested and a test certificate should be provided showing the results of the tests, including the free-air flow rate obtained at an inlet vacuum of 450 mmHg. Testing in component form is not acceptable. All Vacuum pumps must be air-cooled, oil lubricated type suitable for both continuous and frequent start/stop operation at nominal inlet vacuum levels of between 475 mmHg Indigineous 6 SITC of Vaccum Pump 3 Hp duplex system with receiver Capacity 250 Ltrs and bacteria filters as per HTM standard incl electrical system Indigineous 7 Surface mounted Vacuum Outlet (Front loading BS Type) It should fully complies and meets with the requirements of the NFPA-99 It should be CE marked . Terminal units should have gas indexing geometry to BS 5682:1998. Terminal unit front fascia should be made of metal. Gas specific components comprising the terminal unit second fix should be manufactured from diecast zinc alloy or similar hard wearing metal. Indigineous 8 Ward Vacuum unit with 600 ml jars Vacuum Regulator and a 600ml polycarbonate collection jar with lid and plastic mounting bracket. Indigineous 9 High pressure anti static tubing for Vacuum (yellow) Indigineous 10 Copper Pipes (Medical Grade): Oxygen distribution pipeline shall be suitably designed for connection of hospital wards with Jumbo Cylinder manifold/ Liquid Dura system / PSA Oxygen plant with parallel connection and separate isolation valve. Each hospital ward shall have individual isolation valve from header. The piped distribution system should use copper pipes manufactured from phosphorous de-oxidised non-arsenical copper to BS EN 1412:1996 grade CW024A (Cu-DHP), manufactured to metric outside diameters and having mechanical properties in accordance with BS EN 13348:2008 in either R250 (half hard) or R290 (hard). Degreasing of pipe should be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS EN 13348:2008. As per NHS C11 section 05 the copper tube should have BS kite mark and certificate number (mandatory). Indigineous 10.1 12mm OD medical grade copper pipe Indigineous 10.2 15mm OD medical grade copper pipe Indigineous 10.3 22mm OD medical grade copper pipe Indigineous 10.4 28mm OD medical grade copper pipe Indigineous 11 Isolation valves suitable for Medical Oxygen gas, Brass body Indigineous 11.1 15mm Isolation valve Indigineous 11.2 22mm Isolation valve Indigineous 11.3 28mm Isolation valve Indigineous 12 Gas Alarm panel - It should fully comply and meet the requirements of the NFPA99. It should be capable of monitoring up to 6 gas services by means of pressure sensors that detect deviations from the normal operating limits.. The cover, back box and bezel should be of polyester powder. A single tamperproof fastener should be used to gain access to the hinged door. It should have each gas service displayed by colored LED’s to show ‘Normal’ (green), ‘Low’ and ‘High’ pressure (red) conditions. Medical vacuum systems should be displayed in the ‘Normal’ (green) and ‘Low’ vacuum (red) conditions. Failure indicators should be displayed by flashing lights and normal indications should be steady. Each LED block indicator should be a plug-in component with individual long life LED’s connected in parallel in two banks to provide duplex circuits. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided. Indigineous 12.1 Area alarm panel for 2 gas service. Indigineous
Basic Detail
Tender No GEM/2022/B/2411951
Bidding Type Tender
Location
City Nandurbar
State Maharashtra
Key Dates
Publish Date 04 Aug 2022
Submission Date 15 Aug 2022
Open Date 15 Aug 2022
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 25000
Exemption Not Available
Document List
3654616_Boq_3.xlsx
f92dbf3e-dc6c-4906-9333-553e4818da51.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 04, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 15, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 15, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xlsx

3654616_Boq_3.xlsx

pdf

f92dbf3e-dc6c-4906-9333-553e4818da51.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders