Supply And Installation Of Quality Control Equipments At Pwd Regional Labroratory, Ajmer Supply And PARTICULARS 2 Supply and Installation of Mixer machine for GSB & WMMfor Mix Designwith calibration certificate required from NABL accredition agency after installation at site 3 Supply and Installation & Commisioning of Silt & Clay contents Testing Apparatus to meet requirements as per IS- 2386 Part II 1963 complete in all respects with calibration certificate 4 Supply and Installation of Digital Printer for Micro controller based CTM (Capacity 2000 kN) with touch panel display andFlexural assembly 250kNCapacity along with Digital printer (Refer IS 516, IS 14858) with calibration certificate required from NABL accredition agency after installationat site 5 Supply of Standard Weight with The calibration certificate required from NABL accredition agency .Make: Wensar , Metller or EquivalentClass-M1Range - 100kgStandard – OIML R111Material: 304 Stainless SteelShape: Cylindrical with knobFinish: Mirror Polish 6 Supply and Installation of Capping Gypsum, Compressive strength:560kgf/cm2 (56Mpa or 8000 psi) with glass plates. As per Ref IS: 516 7 Supplyof Beam mould 100mmx100mmx500mm size with the calibration certificate required from NABL accredition agency after supply at site 8 Supplyof Beam mould Beam mould 150mmx150mmx700mm size with the calibration certificate required from NABL accredition agency after supply at site 9 Supply of Refrigerator 300 Litre CapacityDouble door branded manufacturer like Whirlpool, Godrej, LG, Samsung, Panasonic, and Videocon. Maintaining thetemperature of freezer (-)15 degree centigrade and freeze cooling capacity maximum of 5 degree centigrade, having differentshelf with 5 year warranty of compressor and 1 year warranty of complete item, with auto cut-off, having all safety protection,with stabilizer of branded manufacturer 10 Supply of Air Conditioner for Cement&Bitumen Testing 11 Supply and Installation ofSolubility Test Apparatuswith the calibration certificate required from NABL accredition agency after installationat site 12 Supply and fixingof Weighing Balance 500 gm with 0.01gm senstivity shall be providedwithNABL approved calibration certificate 13 Supply & fixingof Filter paper no.5 id Method B used of IS 1216,shall be provided with NABL approved calibration certificate 14 Supplyof Toluene / Benzene,for Solubility test shall be provided with NABL approved calibration certificate 15 Supply of Trichloroethylene 500 ML Bottlefor Solubility test shall be provided with NABL approved calibration certificate 16 Supply of Distilled Waterfor Sulubility test 17 Supply of Carben disulfied for Sulubility test 18 Supply of Canon-Manning Viscosity tube(Tube size 12 for obtaining absolute viscosity) with manufacturer certificate. Ref. IS:1206 & IS: 1208 with the calibration certificate required from NABL accredition agency after installationat site 19 Supply of Certified Reference Material for internal calibration certificate required from NABL accredition agency 20 Supply of Digital Room thermometer with humidity indicator 21 Supplyof Humidifier Equipment, due humidifier with Digital display controllerwith The calibration certificate required from NABL accredition agency .Make- HTC, Mextech PPI/Metravi or EquivalentTechnical Specs of Machine:-Temp Range: -50 to +70 deg cel , Resolution: 0.1deg CelHumidity Range: 10% to 99% RH Resolution: 1% 22 Supplyof LPG Hotplate, Stove, Stirrer for Bitumen sample preparation 23 Universal Penetrometer for LL & BT PentrationTheunit is compact with in build timer to control duration of pentration preset in factory to 5 seconds. The instrument is provided levelling screws ref. Standrad IS: 1448(part 60) ASTM D 937, IP 179,BS: 4698,ASTM D217, IP 50 ISO 2137. for empirial estimation of the consistency of lubricating grease and petroleum. Made of brass with a hundred steel tip. the stem of the cone is interchangeable with all types of penetrometers manufactured to close tolerance providing a unfilled cone and ensuring that there is no shoulder between the tip and the body. Weight : 102.5+ 0.05kg Bitumen penetration kitPenetration needle Transfer Dish made of copper Aluminium Sample containers ,Set of Two 24 Repairing &calibration certificate from NABL accerdited agency of Universal Penetrometer For Liquid limit , Plastic Limit& Bitumen Penetration 25 Repairing &calibration certificate from NABL accerdited agency of Compaction Factor Appartus 26 Repairing of weighing balance ,accurecy 1g, capacity 20 kg and calibration certificate from NABL accerdited agency 27 Calibration certificate from NABL accerdited agency of CBR Moulds 28 Repairing & Cailbration certificate from NABL accerdited agency of CBR Digital testing Assembly without Moulds 29 Calibration certificate from NABL accerdited agency of Oven with PID control 24x24x36 for soil &aggergate 30 Repairing & calibration certificate from NABL accerdited agency of Impact Testing Machine for impact test 31 Calibration certificate from NABL accerdited agency of Crushing mould of aggregate 32 Calibration certificate from NABL accerdited agency ofFlakiness indexGauge 33 Calibration certificate from NABL accerdited agency of course sieve &fine sieves (wire brush) (40mm,20mm,10mm,1.18mm,2.26mm,4.75mm,9.50mm,19mm,25mm,600micron,300micron,150micron 34 Calibration certificate from NABL accerdited agency ofPAN 35 Calibration certificate from NABL accerdited agency of CTM of capacity of 200KN for compressive strength testing of cc cube/cc core/mortar cube /bricks 36 Calibration certificate from NABL accerdited agency of Accelerated curing tank cum Normal curing tank for 12moulds of 150mm size. 24-hours cycle from time of mixing.(IS 9013) for Water absorption test (Concrete/Cement/Brick/Paver block/Tiles) 37 Calibration certificate from NABL accerdited agency of Ductility testing machine with digital display & cooling for Ductility test 38 Repair & calibration certificate from NABL accerdited agency of Water bath forDuctility test 39 Calibration certificate from NABL accerdited agency of Ring and Ball apparatus Digital set for Softening point 40 Repair&calibration certificate from NABL accerdited agency of Flash & Fire Point test apparatus (Pensky-Martens Closed Tester) for Flash & Fire Point Test 41 Repair & calibration certificate from NABL accerdited agency of Viscometer apparatus (Kinematic & Absolute Viscosity) 42 Repair & calibration certificate from NABL accerdited agency of Bitumen extraction apparatus (Centrifuge extractor), capacity 1500g Electrically operated forBinder content 43 Calibration certificate from NABL accerdited agency of Asphalt Content tester 44 Calibration certificate from NABL accerdited agency of Pyknometer or digital density meter/ Non-nuclear Asphalt density gauge for density 45 Calibration certificate from NABL accerdited agency of Digital Modified Marshall Apparatus 50kN, single speed, New model for 6” dia sample & 4” dia sample 46 Repair & maintainance of automatic Compactor for bitumen mix &calibration certificate from NABL accerdited agency