}

Repair / Maintenance Of Summer Appliances Window Type / Split Type / Cassatte Type Acs And Allied Services At Kashmir House Under Ge New Delhi- 1 Labour For Checking And Attending Complaints Of Acs, Refrigerators Etc Of Any Capacity, Rect, delhi-Delhi

Military Engineer Services-MES has published Repair / Maintenance Of Summer Appliances Window Type / Split Type / Cassatte Type Acs And Allied Services At Kashmir House Under Ge New Delhi- 1 Labour For Checking And Attending Complaints Of Acs, Refrigerators Etc Of Any Capacity, Rect. Submission Date for this Tender is 31-08-2022. Rough Finishing Tools Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

33380437
Corrigendum : Repair / Maintenance Of Summer Appliances Window Type / Split Type / Cassatte Type Acs And Allied Services At Kashmir House Under Ge New Delhi- 1 Labour For Checking And Attending Complaints Of Acs, Refrigerators Etc Of Any Capacity, Rect
Open Tender
Indian
Delhi
delhi
31-08-2022

Tender Details

Repair / Maintenance Of Summer Appliances Window Type / Split Type / Cassatte Type Acs And Allied Services At Kashmir House Under Ge New Delhi- 1 Labour For Checking And Attending Complaints Of Acs, Refrigerators Etc Of Any Capacity, Rectification Minor Defects And Make The Equipment Functional Complete All As Specified And Directed. ( Any Parts Required Forreplacementshall Be Measured And Paid Separately Under Respective Items ) Notes:- ( A ) The Contractor Should Detail Minimum One Ac Mechanic & One Helper To Attend Complaints In Kashmir House . ( B ) The Complaint Should Be Attended On Same Day With In 3 Hours . ( C ) ) If The Complaint Not Attended / Not Completed On Same Daywith In Three Hours Recovery Will Be Done As Follows:- ( I ) For First Day Rs.1000 / - ( Ii ) For Second Day Rs.1500 / - ( Iii ) For Nextevery Day Rs.2000 / - 2 Servicing Of Window Type Ac 1.5 / 2 Ton Capacity Ofany Make / Model By Taking Out The Ac, Cleaning Of Evaporating Coil, Condensing Coil With Water & Brush To Remove Dust Including Cleaning Of Filter, Greasing Oiling Of Fan Motor And Checkingof Electric Circuit For Smooth Functioning Of Ac 3 All As Per Item No 2 Above But Split Type Ac Of Any Type And 1.5 / 2 Ton Capacity 4 Servicing Of Three Phase Cassette / Tower Type Split Ac 3.5 To 4.0 Ton Capacity Of Any Make / Model With Indoor And Outdoor Unit By Taking Out The Ac, Cleaning Of Evaporating Coil, Condensing Coil With Water & Brush To Remove Dust Including Cleaning Of Filter, Greasing, Oiling Of Fan Motor And Checking Of Electric Circuit For Smooth Functioning Of Ac Complete All As Specified. Note: Unserviceable Spares Parts Required To Be Replaced Shall Be Measured And Paid Separately Under Respective Items. 5 Supply Only Against Repairs Running Capacitor Combination ( 50 Mfd + 6 ) / ( 50+4 ) Mfd 230 Voltfor Ac Upto 4.00 Ton . 6 Supply Only In Replacementrunning Capacitor 6 Mfd 230 Volt 7 Supply Only In Replacementrunning Capacitor 4 Mfd 230 Volt 8 Supply & Charging Gas Refrigerant R-22 / 410 A / Or As Existing To Window Type / Split Type / Cassette / Package Type Ac Up To 4 Ton Capacity Including Removing Of Leakage If Any And Testing Complete All As Specified & Directed By Engineer-In-Charge 9 Supply Onlyin Replacementstarting Relay Suitable For 1.5 / 2 Ton Capacity Ac 10 Supply Onlyin Replacementover Load Protector Suitable For 1.5 Ton Capacity Ac 11 Supply Onlyin Replacement Thermostat Switch Suitable For 1.5 / 2 Ton Capacity Ac 12 Supply Only Against In Repair Item Ofstarting Relay Suitable For 4.0 Ton Capacity Ac Complete All As Specified. 13 Supply Only Against In Repair Item Ofover Load Protector Suitable For 4.0 Ton Capacity Ac Complete All As Specified. 14 Supply Only Against In Repair Item Ofthermostat Switch Suitable For 4.0 Ton Capacity Ac Complete All As Specified. 15 Supply And Fixingin Replacementreciprocating / Rotary Type Compressor Suitable For 1.5 To 2.0Ton Capacity Split Type Ac Of The Same Make And Model As Per Existing Make Of Acs, Refixing Including Brazing Work Etc, Pressuretesting & Establishing Vacuum For Dehydration Complete All As Specified And Directed. 16 Supply And Fixingin Replacementreciprocating / Rotarytype Compressor Suitable For 1.5 To 2 Ton Capacitywindow Type Ac Of Thesame Make And Model As Per Existing Make Of Acs, Refixing Including Brazing Work Etc, Pressuretesting & Establishing Vacuum For Dehydration Complete All As Specified And Directed. 17 Supply And Fixingin Replacementany Type Of Compressor Suitable For Inverter Type 1.5 To 2 Ton Capacitysplitac Of Thesame Make And Model As Per Existing Make Of Acs, Refixing Including Brazing Work Etc, Pressuretesting & Establishing Vacuum For Dehydration Complete All As Specified And Directed. 18 Supply And Fixingin Replacement Ofthree Phase Compressor Suitable For 3.5 To 4.0 Ton Capacity Suitable Of Cassette / Tower Acof The Same Make And Model As Per Existing Make Of Acs Complete All As Specified And Directed. 19 Supply Onlyin Replacement Wiring Kit Suitable For 1.5 / 2 Ton Capacity Ac Complete All As Specified & Directed 20 Supply Only In Replacement Air Filter Synthetic / Nylon As Per Existing Size And Shape Suitable For 1.5 / 2 Ton Capacity Window Type Acs 21 Supply Only In Replacement Air Filter Synthetic / Nylon As Per Existing Size And Shape Suitable For 1.5 / 2 Ton Capacity Split Type Acs 22 Supply Only Against In Repair Item Ofair Filter Synthetic / Nylon Type As Per Existing Size And Shape Suitable For 3.5 / 4.0 Ton Capacity Cassette Type Split AcS Complete All As Specified. 23 Supply Only In Replacement New Fan Motor ( Indoor / Outdoor ) 1 / 4, 1 / 5 Hp Single / Double Shaft As Per Existing Model Suitable For Splittype Acs 1.5 / 2 Ton Complete All As Specified And Directed. 24 Supply Only In Replacementnew Dc Fan Motor ( Indoor / Outdoor ) 1 / 4, 1 / 5 Hp Single / Double Shaftas Per Existing Model Suitable For Splittype Acs 1.5 / 2 Ton Complete All As Specified And Directed. 25 Supply Only Against In Repairoffan Motor Single / Double Shaft As Per Existing Model Suitable For 3.5 / 4.0 Ton AcS Of Any Make / Type Complete As Per Requirement On Site All As Specified. 26 Supply Only Against In Ofnew Dcfan Motor Single / Double Shaft As Per Existing Model Suitable For 3.5 / 4.0 Ton Cassette TypeacS Of Any Make / Type Complete As Per Requirement On Site All As Specified. 27 M & Lfor Rewinding Of Fan Motor Suitable For Acs Up To 4 Ton Capacity With Super Enamelled Copper Winding Wire Of Same Gauge Including Replacement Of Insulating Material, Bushes And Shaft All As Specified & Directed 28 Supply Onlyin Replacement Pvc Insulatedflexible Copper Conductor 3 Core 1100V Grade Of Size 2.5 Sqmm. 29 Supply Onlyin Replacement Pvc Insulatedflexible Copper Conductor 3 Core 1100V Grade Of Size 4.0 Sqmm. 30 Supply Onlyin Replacementcondenser Fan Blade Made Out Ofplastic Suitable For Upto 2 Ton Capacity Window Type Acs. 31 Supply Onlyin Replacementcondenser Fan Blade Made Out Ofplastic Suitable For Upto 2 Ton Capacity Split Type Acs. 32 Supply Only Against In Repairofcondenser Fan Blade Made Out Of Aluminium Suitable For Upto 4.0 Ton Capacity Cassette Type Split AcS Complete All As Specified & Directed. 33 Supply Onlyin Replacement Of Evaporatingair Blower Made Out Ofsuitable For Upto 2 Ton Capacity For Window Type Ac All As Specified And Directed 34 Supply Onlyin Replacement Of Evaporatingair Blower Made Out Of Suitable For Upto 2 Ton Capacity For Split Type Ac All As Specified And Directed 35 Supply Only Against In Repairofindoor Air Blower Made Out Ofsuitable For Upto 4.0 Ton Capacitytype Split AcS Complete All As Specified & Directed. 36 Supply Onlyin Replacement Of Synthetic Rubber Tube Insulation Of Thickness 9 Mm & Internal Diameter - 6.0 Mm ( 1 / 4 ) For Refrigerant Copper Piping Of Split Ac Units. 37 Supply Onlyin Replacement Of Synthetic Rubber Tube Insulation Of Thickness 9 Mm & Internal Diameter - 13.0 Mm ( 1 / 2 ) For Refrigerant Copper Piping Of Split Ac Units. 38 Supply Onlyin Replacement Of Synthetic Rubber Tube Insulation Of Thickness 9 Mm & Internal Diameter - 9 Mm ( 3 / 8 ) For Refrigerant Copper Piping Of Split Ac Units.Make:- Supreme / Gulf-O-Flex / Superlon. 39 Supply Onlyin Replacement Of Synthetic Rubber Tube Insulation Of Thickness 9 Mm & Internal Diameter - 16 Mm ( 5 / 8 ) For Refrigerant Copper Piping Of Split Ac Units.Make:- Supreme / Gulf-O-Flex / Superlon. 40 M & L For Replacement Of Front Grill Suitable For Window Type Acs Upto 2 Ton Capacity Of Any Make As Per Existing Size And Shape. 41 M & L For Replacement Of Reverse Valve System Suitable To 1.5 / 2 Ton Split / Window Ac For Heating Option. ( Gas Charging Shall Be Paid And Measured Under Respective Item ) 42 Supply Onlycopper Tubing Heavy Duty Inner Dia 6 Mm ( 1 / 4 ) For Refrigerant For Acs. Make-Mandev / Mandley / Uniflow 43 Supply Onlycopper Tubing Heavy Duty Inner Dia 13Mm ( 1 / 2 ) For Refrigerant For Acs. 44 Supply Onlycopper Tubing Heavy Duty Inner Dia 9 Mm ( 3 / 8 ) For Refrigerant For Acs. 45 Supply Onlycopper Tubing Heavy Duty Inner Dia 16 Mm ( 5 / 8 ) For Refrigerant For Acs. 46 Supply Onlycondensing Coil Suitable For 1.5 / 2 Ton Splittype Acs As Per Existing Size / Shape And As Per Existing Make. 47 Supply Onlyevaporating Coil Suitable For 1.5 / 2 Ton Splittype Acs As Per Existing Size / Shape And As Per Existing Make. 48 Supply Onlybrass Flare Nut / Connector Heavy Duty Of Size 6 Mm / 9 Mm ( 1 / 4, 1 / 2 ) As Per Existing Make. 49 Repair To Control Processing Board ( Remote Control Kit ) With Hand Set Including Replacement Of Current Transformer, Ics, Diodes, Resistances, Sensors Etc Complete For 1.5 / 2 Ton Split Type Acs Of Any Make & Model. 50 Repair To Control Processing Board ( Remote Control Kit ) Inverter Typewith Hand Set Including Replacement Of Current Transformer, Ics, Diodes, Resistances, Sensors Etc Complete For 3.5 / 4 Ton Split Type Acs Of Any Make & Model. 51 Supply And Fixingin Replacement Split Type Ac 1.5 / 2 Tonindoorunit Kitwithpcb Complete Withsensor Complete With Fixing Plate Suitable To Non Inverter Type Ac Complete All As Specified And Directed. 52 Supply And Fixingin Replacement Split Type Ac 1.5 / 2 Tonindoorpcb Unit Kitcomplete Withsensor Complete With Fixing Plate Suitable To Inverter Typemodel And Make Ac All As Specified And Directed. 53 Supply And Fixingin Replacement Split Type Ac 1.5 / 2 Ton Outdoor Unit Kit Complete With Compressor, Condensor Coil, Condenser Fan With Blade And Sensor Suitable To Non Inverter Typeexisting Model And Make Ac All As Specified And Directed. 54 Supply And Fixingin Replacement Split Type Ac 1.5 / 2 Ton Outdoor Unit Kit Complete With Compressor, Condenser Coil, Condenser Fan With Blade And Sensor Suitable Toinverter Typeexisting Model And Make Ac All As Specified And Directed.Make:- Carrier / Blue Star / Napolean / Totaline. 55 Supply And Fixingin Replacement Window Ac Kit 1.5 / 2 Tonpcbwith Sensorcomplete With Condensing Coil, Fan Motor, Blower And Motor, Compressor And Grill Complete Suitable To Non Inverter Type Existing Model And Make Ac All As Specified And Directed.Make:- Carrier / Napolean / Skoda. 56 Supply Only In Replacementair Direction Changer Louver Motor ( Swing Motor ) Suitable For Split Type Acs As Per Existing Make And Model 57 Supply Only In Replacement Cordless Remote For Inverter Type Acshot & Cool Suitable For 1.5 Ton Ac As Per Sample. 58 Supply Onlyin Replacement Cordless Remote For Acssuitable For 1.5 / 2 Tonsplit / Windowac As Per Sample. 59 Servicing Of Refrigerators Of 165 To 310 Ltrcapacitysingle Door Ofany Make / Model By Cleaning Of Condensing Coil With Wire & Brush To Remove Dust Includingcheckingof Electric Circuit For Smooth Functioning Complete All As Specified And Directed By Engr-In-Charge 60 Supply And Fixingin Replacementnew Compressor Suitable For 165 / 310Ltr Capacity Refrigerator Reciprocating Type Complete All As Specified And Directed. 61 Supply And Fixingof Monkey Menace Protection Device With Pvc Spikes Size As Per Sample All As Specified And Directed 62 Taking Down Ac Of Any Type, Any Capacity And Any Make, Dismantling Of Copper Pipe, Transportation To Work Shop For Carrying Out Necessary Repairwork, Transportation Back To Location Of Installation , Reinstallation / Refixing In Position After Complete Repairs As Required And Making Functional Includingtesting Complete All As Specified And Directed. 63 Supply And Fix Of Drain Pipe Of Any Size Suitable For Split Ac Of Capacity 1.5 / 2 / 3.5 / 4 Tr As Per Sample All As Specified And Directed 64 M&L In Replacement Metalclad Plug & Socket Board Sp&N Enclosure With Single Pole And Earth Metal Plug & Socket Suitable For 20 Amps Mcb Ac, 220 V, 50Hz . 65 M&L In Replacement Modular Acboard Sp&N Enclosure With Single Pole And Earth Metal Plug & Socket Suitable For 20 Amps Mcb Ac, 220 V, 50Hz 66 Supply, Installing, Testing And Commissioning In Replacement Factory Made And Tested Outdoor Type, Platform Mounted, Phase Sequence Corrector Of Capacity 63 A , 3 Phase 4 Wire, 415 Volts, 50 Hz, Platform Mounted. The Phase Sequence Corrector Shall Be Dust And Vermin Proof, Protection Class ( Ip-54 ) And Made Of 2.00 Mm Thick Stainless Steel Sheet 316L Thick & Suitable Frame Work / Support Made Out Of 75 Mm Stainless Steel Flat Channel, Front Opening Type With Aprons For Cable Entry, With Proper Ferrule & Cable Gland, Internal Wiring With Pvc Insulated Multistranded Copper Conductor Frls Cable Of Adequate Size But Not Less Than 1.5 Sqmm Complete. The Scope Of Work Also Comprising Of The Following:-Make:- Havells / Schneider / Abb / L&T / Universal Switch Gear Control. Note- Work Includes Civil Work Like Excavation And Preparation Of Pcc Plinth 67 Phase Sequence Corrector Of Capacity 63 A , 3 Phase 4 Wire, 415 Volts, 50 Hz With Facility To Change Over From Automatic To Manual, Microprocessor Release ( Over Load, Short Circuit, Instantaneous Single Phasing, Phase Reversal ) , Pre Trip Alarm And Individual Fault Indication Led With Fully Rated Neutral With Inbuilt Protection. The Over Load Release Shall Be Adjustable Type, Protection:-Avoid Damages During Phase Sequence Changes Or Reversal.• The Sequence Corrector Will Switch Off, During The Single Phasing Or Imbalance Voltage Occur & Later, Auto-Reset After Restoration.• No Break Downs Of Three Phase System Due To The Change In Sequence.• Bye Pass Selector Switch In Case Of Controller Faulty. 68 The Panel Manufacturer Should Have Following Govt. Approved Certificates: 1. Cpri Certification Degree Of Protection Ip-542. Cpri Certification Short Circuit Withstand Strength Should Be 50Karms For 1.0 Sec With Initial Peak Of 105Ka 3. Cpri Certification Rated Current For Short Circuit Not Less Than 4000A With Rated Insulation Voltage 660V4. Iso 9001 Certified 69 Supply, Install, Commissioning And Testing In Replacement Of Lt Panel Board Outdoor Type Floor Mounted Of Factory Made Powder Coated Made Out Of Outside Body Of 2.00 Mm Thick Stainless Steel Sheet 316L Thick & Suitable Frame Work / Support Made Out Of 75 Mm Stainless Steel Flat Channel, , Locking Arrangement, Front Side And Rear Side Opening Arrangement Of Suitable Size, Incl Mounting Onduly Grouting Or Welded On Floor. Aluminium Bus Bar Tpn Of 600 A For Mccb To All Feeders To Accommodate Following Items:- ( A ) Incoming Mccb 250 Amp 50 Ka 4 Pole, Microprocessor Based Energy Release-01 No Cat No Hmt250nr Hageurs, Equivalent In Legrand / Schneider ( B ) Outgoing Mccb 100 Amp 40 Ka 3Pole, Microprocessor Based Energy Release-04 No Hns100 Nr ( C ) Ryb Indication For Each Incoming & Outgoing Supplies-01 Set ( D ) Voltmeter, Amp Meter, Digital Type With Ct’S &Selector Switch-01 Set ( E ) Termination Of All Cables With Suitable Size Thimble And Gland-1Job ( F ) Termination Of All Cables With Suitable Size Thimble And Gland-1 Job . Make For Ss Enclosure :- Havells / Schneider / Abb / L&T / Universal Switch Gear Control. Note- Work Includes Civil Work Like Excavation And Preparation Of Pcc Plinth 70 Supply, Install, Commissioning And Testing In Replacement Of Lt Panel Board Indoor Type Floor Mounted Of Factory Made Powder Coated Made Out Of Outside Body Of 2.00 Mm Thick Stainless Steel Sheet 316L Thick & Suitable Frame Work / Support Made Out Of 75 Mm Stainless Steel Flat Channel, Locking Arrangement, Front Side And Rear Side Opening Arrangement Of Suitable Size, Incl Mounting Onduly Grouted Or Welded On Floor. Aluminium Bus Bar Tpn Of 600 A For Mccb To All Feeders To Accommodate Following Items:- ( A ) Incoming Mccb 200 Amp 50 Ka 4 Pole, Microprocessor Based Energy Release -01 No.Cat No Hmt250nr Haguer, Equivalent In Legrand / Schneider ( B ) Outgoing Mccb 100 Amp 40 Ka 3Pole -04 No Microprocessor Based Energy Release -01 No.Cat No Hns100nr Hager, Equivalent In Legrand / Schneider ( C ) Changeover On Load For Open Execution 200 Amp ( D ) Ryb Indication For Each Incoming & Outgoing Supplies-01 Set ( E ) Voltmeter, Amp Meter, Digital Type With Ct’S &Selector Switch-01 Set ( F ) Termination Of All Cables With Suitable Size Thimble And Gland-1Job ( G ) Termination Of All Cables With Suitable Size Thimble And Gland-1 Job . Make For Ss Enclosure :- Havells / Schneider / Abb / L&T / Universal Switch Gear Control . Note- Work Includes Civil Work Like Excavation And Preparation Of Pcc Plinth 71 Supply Only In Replacement Voltage Stabilizer Of Capacity 3 To 5 Kva , Copper Wounded Made Of Metallic Steel Body Complete All As Specified And Directed 72 S&F In Replacement Of Plug Top3 Pin, 15 Amps, 230 Volts, 50 Hz Ac Complete All As Specified. 73 M&L For Taking Down Split / Window Ac And Shifting From One Position To Other Within The Premises Complete With Copper Tubing Indoor Plate And Copper Tubing Complete With All Accessories With Making Good The Disturbed Surfaces With Cement Plaster And Pop . Complete All As Specified And As Directed By Engr-In-Charge 74 S&F Sub Main Wiring In Replacement With Two Runs Pvc Insulated Unsheathed Frls Stranded Copper Conductor Cable Of Size4.0 Sqmm Along With One Run Of Pvc Insulated Unsheathed Stranded Copper Conductor Cable Of Size 2.5 Sqmm As Earth Wire Connected To Earth Dollyfixed On Surface Of Wall / Ceiling / In Concealed Pvcconduits Complete Including Cutting Chases And Making Good To Walls At Disturbed Area All As Specified And Directed. Make Of Conduit- Plaza / Kalingamake Of Cable- Rr Kabel / Havells / Polycabnote :- Two Run Of 4.0 Sqmm Copper Conductor Cable, One Run Of 2.5 Sqmm Copper Cable And One Run Of Pvc Conduit Shall Be Measured As One Unit Length 75 All As Per Item No 74 Here-In-Before But Size Of Cable 2 X6sqmmcomplete Along With Cable 1X2.5 Sqmm Frls Type For Continuous Earth Wire And Connected To Common Earth Dolly Complete All As Specified.Make-Rr / Havells / Polycabnote :- Two Run Of4 Sqmm Copper Conductor Cable, One Run Of 2.5 Sqmm Copper Cable And One Run Of Pvc Conduit Shall Be Measured As One Unit Length 76 Supply Only In Replacement Of Factory Made Load Line DbS Double Door Made Out Of Crca Mild Steel Sheet With Insulating Materials Like Polyester Epoxy Coated Surface Mounting 12 Way Tpn 415 Volts, Ip 43 With Suitable Busbar, Neutral Link & Earth Link Suitable For Mccb Tp As Incomer & Mcb Sp / Tp As Out Going Complete All As Specified 77 Supply Only In Replacement Of Factory Made Load Line DbS Double Door Made Out Of Crca Mild Steel Sheet With Insulating Materials Like Polyester Epoxy Coated Surface Mounting 8 Way Tpn 415 Volts, Ip 43 With Suitable Busbar, Neutral Link & Earth Link Suitable For Mccb Tp As Incomer & Mcb Sp / Tp As Out Going Complete All As Specified. 78 Supply Only In Replacement Of Mccb Tp / Tpn125 Amp, 25Ka Thermal Type Complete All As Specified. 79 Supply Only In Replacement Of Mccb Tp / Tpn 160 Amp, 25Ka Thermal Type Complete All As Specified. 80 Supply Only In Replacement Of Mcb Sp 40-63 Amp, 10Ka All As Specified. 81 Supply & Fixed Rigid Non-Metallic 20 Mm External Dia Pvc Conduit Concealed On Surface To Wall / Ceiling For Drain Out Of Water From Split Type And Window Typebut Inclusive Of All Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Up To Outdoor Unit To Ground Floor Level All Directed By Engr-In-Charge. 82 Supply Only In Replacement Flexible Pipe 15 / 20 / 25 Mm Dia White Colour Complete All As Specified And Directed 83 Supply Only In Replacement Of Mcb Spn 20-32 Amp, 10Ka All As Specified. 84 M & L For Making Suitable Hole In The Wall To Fix Window Or Split Ac And Maintain The Surface As Per Existing Note : ( A ) Plastering , Putty , Painting Included In The Quoted Rate . ( B ) Covering The Window By Ply If Necessary Also Included In The Quoted Rate 85 Supply Only In Replacement Wall Stand / Chauki Stand To Fix Outdoor Of Split / Cassette Ac Made Ofmetallic Stell Complete All As Specified And Directed 86 Supply Only In Replacement Fastener Upto 8Mm Size Suitable To Fix Wall Stand / Chauki Stand Complete All As Specified And Directed

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-08-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 78000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR / MAINT OF SUMMER APPLIANCES WINDOW TYPE/SPLIT TYPE/CASSATTE TYPE ACs ANDALLIED SERVICES AT KASHMIR HOUSE UNDER GE NEW DELHI
Sl. No. Item Description
1Labour for checking and attending complaints of ACs,Refrigerators etc of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed.(any parts required forreplacementshall be measured and paid separately under respective items) Notes:- (a)The contractor should detail minimum one AC Mechanic & one helper to attend complaints in Kashmir House . (b)The complaint should be attended on same day with in 3 hours . (c))If the complaint not attended/not completed on same daywith in three hours recovery will be done as follows:- (i) For first day Rs.1000/- (ii)For second day Rs.1500/- (iii)For nextevery day Rs.2000/-
2Servicing of Window type AC 1.5/2 Ton capacity ofany make / model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checkingof electric circuit for smooth functioning of AC
3All as per item No 2 above but Split type AC of any type and 1.5/2 Ton capacity
4Servicing of three phase cassette /tower type split AC 3.5 to 4.0 Ton capacity of any make / model with indoor and outdoor unit by taking out the AC, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified. Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
5Supply only against repairs running capacitor combination(50 mfd + 6 ) / (50+4) mfd 230 Voltfor AC upto 4.00 Ton .
6Supply only in replacementRunning capacitor 6 mfd 230 volt
7Supply only in replacementRunning capacitor 4 mfd 230 volt
8Supply & charging gas refrigerant R-22 /410 A/ or as existing to window type/Split type/Cassette/Package type AC up to 4 Ton capacity including removing of leakage if any and testing complete all as specified & directed by Engineer-in-charge
9Supply onlyin replacementstarting relay suitable for 1.5/2 Ton capacity AC
10Supply onlyin replacementover load protector suitable for 1.5 Ton capacity AC
11Supply onlyin replacement thermostat switch suitable for 1.5/2 Ton capacity AC
12Supply only against in repair item ofstarting relay suitable for 4.0 Ton capacity AC complete all as specified.
13Supply only against in repair item ofover load protector suitable for 4.0 Ton capacity AC complete all as specified.
14Supply only against in repair item ofthermostat switch suitable for 4.0 Ton capacity AC complete all as specified.
15Supply and fixingin replacementreciprocating /Rotary type compressor suitable for 1.5 to 2.0Ton capacity split type AC of the same make and model as per existing make of ACs, refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed.
16Supply and fixingin replacementreciprocating/Rotarytype compressor suitable for 1.5 to 2 Ton capacitywindow type AC of thesame make and model as per existing make of ACs, refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed.
17Supply and fixingin replacementany type of compressor suitable for Inverter type 1.5 to 2 Ton capacitysplitAC of thesame make and model as per existing make of ACs, refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed.
18Supply and fixingin replacement ofthree phase compressor suitable for 3.5 to 4.0 Ton capacity suitable of cassette /tower ACof the same make and model as per existing make of ACs complete all as specified and directed.
19Supply onlyin replacement wiring kit suitable for 1.5/2 Ton capacity AC complete all as specified & directed
20Supply only in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity window type Acs
21Supply only in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity split type Acs
22Supply only against in repair item ofair filter synthetic / nylon type as per existing size and shape suitable for 3.5/4.0 Ton capacity cassette type split AC"s complete all as specified.
23Supply only in replacement new fan motor (indoor/outdoor) 1/4,1/5 HP single/double shaft as per existing model suitable for Splittype ACs 1.5/2 Ton complete all as specified and directed.
24Supply only in replacementnew DC fan motor (indoor/outdoor) 1/4,1/5 HP single/double shaftas per existing model suitable for Splittype ACs 1.5/2 Ton complete all as specified and directed.
25Supply only against in repairoffan motor single/double shaft as per existing model suitable for 3.5/4.0 Ton AC"s of any make/type complete as per requirement on site all as specified.
26Supply only against in ofnew DCfan motor single/double shaft as per existing model suitable for 3.5/4.0 Ton cassette typeAC"s of any make/type complete as per requirement on site all as specified.
27M & Lfor rewinding of fan motor suitable for ACs up to 4 Ton capacity with super enamelled copper winding wire of same gauge including replacement of insulating material, bushes and shaft all as specified & directed
28Supply onlyin replacement PVC insulatedflexible copper conductor 3 core 1100V Grade of size 2.5 sqmm.
29Supply onlyin replacement PVC insulatedflexible copper conductor 3 core 1100V Grade of size 4.0 sqmm.
30Supply onlyin replacementcondenser fan blade made out ofplastic suitable for upto 2 Ton capacity window type Acs.
31Supply onlyin replacementcondenser fan blade made out ofplastic suitable for upto 2 Ton capacity split type Acs.
32Supply only against in repairofcondenser fan blade made out of aluminium suitable for upto 4.0 Ton capacity cassette type split AC"s complete all as specified & directed.
33Supply onlyin replacement of evaporatingair blower made out ofsuitable for upto 2 Ton capacity for window type AC all as specified and directed
34Supply onlyin replacement of evaporatingair blower made out of suitable for upto 2 Ton capacity for split type AC all as specified and directed
35Supply only against in repairofindoor air blower made out ofsuitable for upto 4.0 Ton capacitytype split AC"s complete all as specified & directed.
36Supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split AC units.
37Supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split AC units.
38Supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9 mm ("3/8") for refrigerant copper piping of split AC units.Make:- Supreme/Gulf-o-flex/Superlon.
39Supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16 mm ("5/8") for refrigerant copper piping of split AC units. Make:- Supreme/Gulf-o-flex/Superlon.
40M & L for replacement of front grill suitable for window type ACs upto 2 Ton capacity of any Make as per existing size and shape.
41M & L for replacement of reverse valve system suitable to 1.5/2 Ton split/window AC for heating option.(Gas charging shall be paid and measured under respective item)
42Supply onlycopper tubing heavy duty inner dia 6 mm (1/4") for refrigerant for ACs. Make-Mandev/Mandley/ Uniflow
43Supply onlycopper tubing heavy duty inner dia 13mm (1/2") for refrigerant for ACs.
44Supply onlycopper tubing heavy duty inner dia 9 mm (3/8") for refrigerant for ACs.
45Supply onlycopper tubing heavy duty inner dia 16 mm (5/8") for refrigerant for ACs.
46Supply onlycondensing coil suitable for 1.5/2 Ton splittype ACs as per existing size/shape and as per existing make.
47Supply onlyevaporating coil suitable for 1.5/2 Ton splittype ACs as per existing size/shape and as per existing make.
48Supply onlybrass flare nut/connector heavy duty of size 6 mm/9 mm (1/4", 1/2") as per existing make.
49Repair to control processing board( Remote control kit) with hand set including replacement of current transformer, ICs, diodes, resistances, sensors etc complete for 1.5/2 Ton split type ACs of any make & model.
50Repair to control processing board( Remote control kit) inverter typewith hand set including replacement of current transformer, ICs, diodes, resistances, sensors etc complete for 3.5/4 Ton split type ACs of any make & model.
51Supply and fixingin replacement split type AC 1.5/2 Tonindoorunit kitwithPCB complete withsensor complete with fixing plate suitable to non inverter type AC complete all as specified and directed.
52Supply and fixingin replacement split type AC 1.5/2 TonindoorPCB unit kitcomplete withsensor complete with fixing plate suitable to inverter typemodel and make AC all as specified and directed.
53Supply and fixingin replacement split type AC 1.5/2 Ton outdoor unit kit complete with compressor,condensor coil,condenser fan with blade and sensor suitable to non inverter typeexisting model and make AC all as specified and directed.
54Supply and fixingin replacement split type AC 1.5/2 Ton outdoor unit kit complete with compressor, condenser coil, condenser fan with blade and sensor suitable toinverter typeexisting model and make AC all as specified and directed. Make:- Carrier/Blue star/ Napolean/Totaline.
55Supply and fixingin replacement window AC kit 1.5/2 TonPCBwith sensorcomplete with condensing coil, fan motor, blower and motor, compressor and grill complete suitable to non inverter type existing model and make AC all as specified and directed. Make:- Carrier/Napolean/Skoda.
56Supply only in replacementair direction changer louver motor ( swing motor) suitable for split type ACs as per existing make and model
57Supply only in replacement cordless Remote for inverter type ACsHot & cool suitable for 1.5 Ton AC as per sample.
58Supply onlyin replacement cordless Remote for ACssuitable for 1.5/2 tonsplit/windowAC as per sample.
59Servicing of Refrigerators of 165 to 310 ltrcapacitysingle door ofany make / model by cleaning of condensing coil with wire & brush to remove dust includingcheckingof electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge
60Supply and fixingin replacementnew compressor suitable for 165/310ltr capacity refrigerator reciprocating type complete all as specified and directed.
61Supply and fixingof monkey menace protection device with pvc spikes size as per sample all as specified and directed
62Taking down AC of any type, any capacity and any make, dismantling of copper pipe, transportation to work shop for carrying out necessary repairwork, transportation back to location of installation , reinstallation/refixing in position after complete repairs as required and making functional includingtesting complete all as specified and directed.
63supply and fix of drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 TR as per sample all as specified and directed
64M&L in replacement MetalClad Plug & socket board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz .
65M&L in replacement modular ACboard SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz
66Supply, installing, testing and commissioning in replacement factory made and tested Outdoor type, platform mounted, Phase Sequence Corrector of capacity 63 A , 3 Phase 4 Wire, 415 volts, 50 Hz, platform mounted. The Phase Sequence Corrector shall be dust and vermin proof, protection class (IP-54) and made of 2.00 mm thick Stainless Steel Sheet 316L thick & suitable frame work/ support made out of 75 mm Stainless Steel flat channel, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:- Make:- Havells/ Schneider / ABB/ L&T/Universal Switch Gear Control. Note- Work includes civil work like excavation and preparation of PCC Plinth
67Phase Sequence Corrector of capacity 63 A , 3 Phase 4 Wire, 415 volts, 50 Hz with facility to change over from automatic to manual, microprocessor release (over load, short circuit, instantaneous Single phasing, Phase reversal ), pre trip alarm and individual fault indication LED with fully rated neutral with inbuilt protection. The over load release shall be adjustable type, Protection:-Avoid damages during Phase sequence changes or reversal. • The Sequence Corrector will switch off, during the Single Phasing or Imbalance voltage occur & later, Auto-reset after restoration. • No break downs of Three phase system due to the change in sequence. • Bye Pass Selector switch in case of controller Faulty.
68The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-54 2. CPRI Certification Short Circuit withstand strength should be 50kArms for 1.0 Sec with initial peak of 105kA 3. CPRI Certification Rated current for short circuit not less than 4000A with rated insulation voltage 660V 4. ISO 9001 CERTIFIED
69Supply, install, commissioning and testing in replacement of LT panel board outdoor type floor mounted of factory made powder coated made out of outside body of 2.00 mm thick Stainless Steel Sheet 316L thick & suitable frame work/ support made out of 75 mm Stainless Steel flat channel,, locking arrangement, front side and rear side opening arrangement of suitable size, Incl mounting onduly grouting or welded on floor. Aluminium bus bar TPN of 600 A for MCCB to all feeders to accommodate following items:- (a)Incoming MCCB 250 Amp 50 KA 4 pole, microprocessor based energy release-01 no Cat No HMT250NR Hageurs, Equivalent in Legrand/ Schneider (b) Outgoing MCCB 100 amp 40 KA 3pole,microprocessor based energy release-04 no HNS100 NR (c)RYB indication for each incoming & outgoing supplies-01 set (d)Voltmeter, amp meter, digital type with CT’s &selector switch-01 set (e)Termination of all cables with suitable size thimble and gland-1job (f)Termination of all cables with suitable size thimble and gland-1 job . Make for SS enclosure :- Havells/ Schneider / ABB/ L&T/Universal Switch Gear Control. Note- Work includes civil work like excavation and preparation of PCC Plinth
70Supply, install, commissioning and testing in replacement of LT panel board indoor type floor mounted of factory made powder coated made out of outside body of 2.00 mm thick Stainless Steel Sheet 316L thick & suitable frame work/ support made out of 75 mm Stainless Steel flat channel, locking arrangement, front side and rear side opening arrangement of suitable size, Incl mounting onduly grouted or welded on floor. Aluminium bus bar TPN of 600 A for MCCB to all feeders to accommodate following items:- (a)Incoming MCCB 200 Amp 50 KA 4 pole,microprocessor based energy release -01 no.Cat No HMT250NR Haguer, equivalent in Legrand/ Schneider (b) Outgoing MCCB 100 amp 40 KA 3pole -04 no microprocessor based energy release -01 no.Cat No HNS100NR Hager, equivalent in Legrand/ Schneider(c) Changeover on load for open execution 200 Amp (d)RYB indication for each incoming & outgoing supplies-01 set (e)Voltmeter, amp meter, digital type with CT’s &selector switch-01 set (f)Termination of all cables with suitable size thimble and gland-1job (g)Termination of all cables with suitable size thimble and gland-1 job . Make for SS enclosure :- Havells/ Schneider / ABB/ L&T/Universal Switch Gear Control . Note- Work includes civil work like excavation and preparation of PCC Plinth
71supply only in replacement voltage stabilizer of capacity 3 to 5 KVA ,copper wounded made of metallic steel body complete all as specified and directed
72S&F in replacement of plug top3 pin, 15 Amps, 230 volts, 50 Hz AC complete all as specified.
73M&L for taking down Split/Window AC and shifting from one position to other within the premises Complete with copper tubing indoor plate and copper tubing complete with all accessories with making good the disturbed surfaces with cement plaster and POP . Complete all as specified and as directed by Engr-in-Charge
74S&F sub main wiring in replacement with two runs PVC insulated unsheathed FRLS stranded copper conductor cable of size4.0 Sqmm along with one run of PVC insulated unsheathed stranded copper conductor cable of size 2.5 sqmm as earth wire connected to earth dollyfixed on surface of wall/ceiling/in concealed PVCconduits complete including cutting chases and making good to walls at disturbed area all as specified and directed. Make of Conduit- Plaza/Kalinga Make Of Cable- RR Kabel/Havells/Polycab Note :- Two run of 4.0 sqmm copper conductor cable,one run of 2.5 sqmm copper cable and one run of PVC conduit shall be measured as one unit length
75All as per item No 74 here-in-before but size of cable 2 x6sqmmcomplete along with cable 1x2.5 sqmm FRLS type for continuous earth wire and connected to common earth dolly complete all as specified. Make-RR / Havells/ polycab Note :- Two run of4 sqmm copper conductor cable,one run of 2.5 sqmm copper cable and one run of PVC conduit shall be measured as one unit length
76Supply only in replacement of factory made load line DB"s double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 12 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified
77Supply only in replacement of factory made load line DB"s double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified.
78Supply only in replacement of MCCB TP/TPN125 Amp, 25kA thermal type complete all as specified.
79Supply only in replacement of MCCB TP/TPN 160 Amp, 25kA thermal type complete all as specified.
80Supply only in replacement of MCB SP 40-63 Amp, 10kA all as specified.
81Supply & fixed rigid non-metallic 20 mm external dia PVC conduit concealed on surface to wall / ceiling for drain out of water from split type and window typebut inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks up to outdoor unit to ground floor level all directed by Engr-in-Charge.
82supply only in replacement flexible pipe 15/20/25 mm dia white colour complete all as specified and directed
83Supply only in replacement of MCB SPN 20-32 Amp, 10kA all as specified.
84M & L for making suitable hole in the wall to fix window or split AC and maintain the surface as per existing Note : (a) plastering ,putty ,painting included in the quoted rate .(b) covering the window by ply if necessary also included in the quoted rate
85supply only in replacement wall stand /chauki stand to fix outdoor of split/cassette ac made ofmetallic stell complete all as specified and directed
86Supply only in replacement fastener upto 8mm size suitable to fix wall stand /chauki stand complete all as specified and directed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail