| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 metersand lift upto 1.5 m, as directed by Engineer-in-Charge.2.7.1 All kinds of soil |
| 2 | P/L of dry stone soling duly hand packed including all carriages loading unloading complete job before laying of mud mate in trenches and in floors with nallah muck as fillingand ramming of solling in foundation trench with rammers to achive desired compaction of sub-base :incl. all carriages of material involved &head load. |
| 3 | P/L in position cement concrete of specified grade excl. the cast of centering and shuttering: 1:4:8 (1 cement 4: coarse sand 8 graded stone crushed agg.40mm nominal size).Incl. all carriages of material involved. |
| 4 | Providing/laying in position specified grade of Reinforced cement concrete work in plinth, Columns,Suspended Floors etcexcluding cost of centering, shuttering, finishing and reinforcement in (1:1.5 : 3) 1 cement: 1.5 : coarse sand 3: graded stone aggregate 20mm nominal size) incl. all carriages of material involved and Head Load. |
| 5 | Upto Plinth:- |
| 6 | Providing/laying in position specified grade of Reinforced cement concrete work in plinth, Columns,Suspended Floors etcexcluding cost of centering, shuttering, finishing and reinforcement in (1:1.5 : 3) 1 cement: 1.5 : coarse sand 3: graded stone aggregate 20mm nominal size) incl. all carriages of material involved and Head Load. |
| 7 | Suspended Floors/Beams/ In columns etc:- |
| 8 | Providing/laying in position specified grade excluding the cost of centering & shuttering – All work upto plinth level.(M-10 Mix) 1:3:6 (1 Cement: 3 Coarse Sand: 6 graded stone aggregate 20mm nominal size- crushed.) ncl. all carriages of material involved. |
| 9 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete (Thermo-Mechanically Treated bars) including head load & carriage by MT |
| 10 | Brick work with(Common Clay Burnt Up Bricks) in foundation & Plinth incement mortar of mix 1:6 (1 cement: 4 coarse sand)including extra cost above plinth level upto floor V-level. Incl Carriages/Headload of bricks upto site of work complete Job. |
| 11 | Centering and Shuttering, including strutting, propping and removal of form workkitply. Upto Plinth Level, Columns, suspended floors etc including head load & carriage all complete. |
| 12 | Upto Plinth:- |
| 13 | Columns/Suspended Floor:- |
| 14 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 15 | P/L Conduites for electric wiring, Fan Boxes, Light Boxes incl bends all complete including binding conduites with binding wire all complete job: |
| 16 | Fan Boxes: |
| 17 | Light Boxes: |
| 18 | Conduits: |
| 19 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly einforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps andecessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. ( toughnedglass panes as approved by engineer in charge Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 20 | Structural steel work welded in built up sections trusses & framed work including cutting hoisting welding & fixing in position & applying a priming coat of approved steel primer, withtwo or more coates of synthetic enamel approved paint over chajja and eaves boarding. in trusses,Rafters, purlins etc all completeincluding carriage & head load including cost of MS Plate Soffits under Chajja and Eaves Boarding: |
| 21 | Providing and fixing with High rib colour coatedGS sheet roofing including vertical/curved surface including polymer coated J. or L hooks,fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead,0.50 mm thick |
| 22 | Providing ridges or hips of width 60cm overall width plain colour sheets 0.5 mm fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. |
| 23 | 12 -15 mm cement plaster in 1:6 mix incl. all carriages of material involved. including head load & carriage |
| 24 | Providing and laying antiskid vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and hades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete 600x600mm |
| 25 | Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed/Panneled door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles dulyforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. ( Incl cost of Single toughened glass panes/Pannel and silicon sealent ). Note: For uPVC frame, sash and mullion Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate. |
| 26 | Applying 2mm thick white Cement Based Wall Care putty on wall surface for smooth finish (two or more coats) including head load & carriage |
| 27 | Painting walls with two or more coates of cement based water proofing paint(EXCEL) interior as well as exterior. Incl all carraiges and accessories for preparing surface and scaffholding. |
| 28 | Providing and fixing anchor bolts 450 mm long 16-20 mm dia with all nuts washers and gouting of bolts all complete job. |
| 29 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil. |
| 30 | P/F of electric fittings with wire of good quality having heating points 10 nos, fan points 7 nos, lighting points 25 nos and main board/controll panel, switches, pvc conduites of approved brand or as directed at site, including necessary external service line: |
| 31 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete 1\"x1\".5\" |
| 32 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 33 | Sanitary and Plumbing Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. PN-16 pipe , Above 20-25mm OD(SDR-7.4) |
| 34 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC mediumpipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings and assories like tees ,elbows ,collars,cowls ,ptraps,s traps ,door bends etc all complete for all depths as per direction of Engineer-in-charge. 100/75 mm nominal size dia |
| 35 | Providing and fixing of 35 litresgeysers specifications as per IS Standard |
| 36 | Providing and fixing water closet squatting pan (European) as required ) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. |
| 37 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls whereverequired : ,White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 38 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 39 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 40 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 41 | C.P. BRASS FITTINGSProviding and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 42 | Construction of soakage pit 3\" dia and 5\" deep with P.C.Conc linning including earth work in excavation in all kinds of soil, dewaterring of trenches durring execution,incl. all cost and cost of material- complete job. |
| 43 | Constructing of septic tank 8ft x 5 ft x 5 ftouter dimenssions including earth work in excavation in all kinds of soil dewaterring of trenches if required, laying of foundation concrete in 1:2:4 mix in slope on 9\" thick soling ,laying of RCC 9\" foundation concrete incl reienforcement not less than 1.2 qtts/cum brick massonry wall 9\" thick in 1:4 mixincluding 15 mm thick inside plaster in 1:4 cement sand mix with floating coat of neat cement slury, top RCC slab of specific design icl CI cover with frame of heavy duty 2\" x 2\" size, back filling and any sanitary installation-Complete Job. |
| 44 | Providing and layingGranite stone flooring/skirting/dadoo in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 11.66.1 |