| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 2 | Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 3 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 4 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB /Isolator) |
| 5 | 6 way, double door |
| 6 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 7 | Single pole |
| 8 | Single pole and neutral |
| 9 | Supplying, Installation, Testing and commissioning of LED luminiaire aesthetically designed LED flat panel for surface mounting which provides soft-light and glare free symmetrical illumination including connection, interconnection etc completed as required. |
| 10 | Supplying, Installation, Testing and commissioning of 300mm dia sweep exhaust fan of approved make Heavy duty or any other equivalent make with 1400 RPM speed along withall other accessories i.e. louvers etc., and fixing the fan on the existing wall including connection etc as required. |
| 11 | Supply of LED street light fitting of 45 watts, AC 240 volts of make of Pressure die cast Al. housing or its equivalent of make HPL/Philipscomplete with all accessories etc |
| 12 | Earthing with G.I. earth pipe 4.5 mtr. long 40 mm dia including accessories ,and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal /cokeand salt etc as required. |
| 13 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 14 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required. |
| 15 | Supplying and fixing of light class GI pipe of 50 mm dia (nominal) 3 m length along the pole for protection of underground cable as reqd. |
| 16 | Supplying of PVC insulated and PVC sheathed cable of 1.1KV grade Aluminum armoured underground cable confirming to ISI 1554 part I with up to date amendments of the following size at the site of work. |
| 17 | 2 x 16 sq. mm |
| 18 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as reqd. Up to 35 sq. mm (clamped with 1mm thick saddle) |
| 19 | Laying of one no. PC insulated and PVC sheathed/ XLPE power cable of 1.1 KV Grade of following size in the existing RCC/ Hume/ Metal pipe as reqd. Up to 35 sq.mm |
| 20 | Laying of one PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning protective covering and refilling the trench etc. as reqd. Up to 35 sq.mm |
| 21 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 22 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. a. 2 X 16 sq. mm (22mm) |
| 23 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. A. 5/6 Amp Switch |