| 1 | Supplying of one number PVC insulated and PVC sheathed / XLPE power cable (LT aluminium cable, armoured, underground) of 1.1 KV grade of following size as required. (Havells /KEI / Finolex / Polycab)1) 3 ½ x 300 sq. mm. |
| 2 | Supplying of one number PVC insulated and PVC sheathed / XLPE power cable (LT aluminium cable, armoured, underground)of 1.1 KV grade of following size as required.(Havells /KEI / Finolex / Polycab) 1) 3 ½ x 120 sq. mm. |
| 3 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 1) Above 185 sq. mm. and upto 400 sq. mm. [3 ½ x 300 sq. mm.] |
| 4 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including xcavation, sand cushioning, protective covering and refilling the trench etc as required.1)Above 185 sq. mm. and upto 400 sq. mm. [3 ½ x 300 sq. mm.] |
| 5 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including xcavation, sand cushioning, protective covering and refilling the trench etc as required.1)Above 95 sq. mm. and upto 185 sq. mm. [3 ½ x 120 sq. mm.] |
| 6 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.1)Above 185 sq. mm. and upto 400 sq. mm. [3 ½ x 300 sq. mm.] |
| 7 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.1)Above 95 sq. mm. and upto 185 sq. mm. [3 ½ x 120 sq. mm.] |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. 1)Above 185 sq. mm. and upto 400 sq. mm. [3 ½ x 300 sq. mm.] |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.1)Above 95 sq. mm. and upto 185 sq. mm. [3 ½ x 120 sq. mm.] |
| 10 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 1)Above 185 sq. mm. and upto 400 sq. mm. [3 ½ x 300 sq. mm.] |
| 11 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 1)Above 95 sq. mm. and upto 185 sq. mm. [3 ½ x 120 sq. mm.] |
| 12 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 1) 3 ½ x 300 sq. mm. (70 mm) |
| 13 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.1) 3 ½ x 120 sq. mm. (45 mm) |
| 14 | Supplying and laying of following size of G.I. pipe of medium class for crossing the road (without excavating the road - i.e. by making hole using bogie, beneath the road) as required. 1) 80 mm. dia |
| 15 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 16 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 17 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |