Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-08-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-08-2022 |
| Sl. No. | Item Description |
| 1 | REPAIR / MAINTENANCES OF LT OVERHEAD LINES, UG CABLE AND CONNECTED WORK INCLUDING POLE PAINTING, PREMONSOON IN THE AOR OF AGE E/M - II OF GE (NW) VASCO |
| 2 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in Soft/loose soil getting out and levelling of bottom surface to required level for laying UG cable / errection of poles complete all as specified and directed by Engineer-in-Charge. |
| 3 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/ disintegrated rock getting out and levelling of bottom surface to required level complete all as specified and directed by Engineer-in-Charge. |
| 4 | All as per item No. 1.02 above but exc. 1.5m in depth and 1.5m in width in soft/disintegrated rock for errection of poles complete all as specified and directed by Engineer-in-Charge. |
| 5 | Excavation in trenches by cutting of road crossing / PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engineer-in-Charge. |
| 6 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick all as specified. |
| 7 | Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supplying & Laying in trenches Clear Sand/m- Sand for cushioningunder ground cable 8 cm below and 15 cm above complete in level complete all as specified and directed by Engineer-in-Charge.Note: Punned thickness only will be measured and paid. |
| 9 | Supplying & Layingprecast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in trenches for protect to under ground cable complete all as specified and directed by Engineer-in-Charge. |
| 10 | Taking down old unserviceable LT UG cable from any description (trenches, walls, ceilings etc) from various locations, Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 10 Sq mm, 2 core, with aluminium conductor, ISI marked as per IS : 7098 (Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified and directed by Engineer-in-Charge.Note :-(a) Excavation, Concrete cable protection cover, pipe, PCC work for road crossing/hard standing and Sand for cushioning will be measured and paid separately.(b) Cost of glands, aluminium cable lugs (eye lid/barrel/bottle neck type/ ring type or any shape) new nut, bolt and washers of required size/ description are deemed to include in this rate. |
| 11 | All as per item No 1.09 here in before but of size 2 core 16 sqmm |
| 12 | All as per item No 1.09 here in before but of size 4 core 16 sqmm |
| 13 | All as per item No 1.09 here in before but of size 4 core 25 sqmm |
| 14 | All as per item No 1.09 here in before but of size 3 1/2 core 35 sqmm |
| 15 | All as per item No 1.09 here in before but of size 3 1/2 core 50 sqmm |
| 16 | All as per item No 1.09 here in before but of size 3 1/2 core 70 sqmm |
| 17 | All as per item No 1.09 here in before but of size 3 1/2 core 95 sqmm |
| 18 | All as per item No 1.09 here in before but of size 3 1/2 core 120 sqmm |
| 19 | All as per item No 1.09 here in before but of size 3 1/2 core 150 sqmm |
| 20 | All as per item No 1.09 here in before but of size 3 1/2 core 185 sqmm |
| 21 | All as per item No 1.09 here in before but of size 3 1/2 core 240 sqmm |
| 22 | S & F in repairs LT heat shrinkable Straight through cable Jointing kit, complete with jointing material and accessories suitable for 2 core XLPE armoured Aluminium conductor cable of size 10 to 16 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 23 | All as per item No 1.21 here in before but of size 3.5 core 185 to 300 sqmm |
| 24 | Material and labour for fault finding of HT/ LT cables off sizes(for LT cables size35 to 150 sqmm X 3.5 core & for HT cables 50 Sq MM to 120 Sq MM 3 Core) and any lengthwith fault detective machine by thumbing method and suitablevoltage and all as permanufactures instructions including providing straight through joint and additional cable ofsame existing size suitable to site requirement complete including excavation work i.e- opening the fault after excavation and filling suitable size joint kit - straight through joint and meggering the cable after jointing and giving clearance for healthy cable and testing on load after completion of the fault repair on joint HT/LT cable all as specified and directed by Engineer-in-Charge. |
| 25 | Supply and fix in repair changeover swithcs on load changeover switches 4 pole 250 Amps in sheet steel enclosure with enclosure, including necessary spreaders / cable lugs / gland / nut, bolt and washers if required complete all as specified and directed by Engineer-in-Charge. |
| 26 | Suplly & Fix including taking down old UNSV Air Circuit Breaker with new air circuit breaker of capacity 4 pole 415 V electrical draw out type of capacity 800 Amps 3 phase 4 wire 415 V electric supply with rated current of over current trip device of 800 Amp rated ultimate breaking / making capacity of 50 KA and rated service breaking / making capacity of 45 KA with thermal magnetic releasecomplete all as specified & directed by Engineer-in-Charge. |
| 27 | Suplly & Fix including taking down old UNSV Air Circuit Breaker with new air circuit breaker of capacity 4 pole 415 V electrical draw out type of capacity 1250 Amps 3 phase 4 wire 415 V electric supply with rated current of over current trip device of 1250 Amp rated ultimate breaking / making capacity of 50 KA and rated service breaking/making capacity of 45 KA with thermal magnetic releasecomplete all as specified & directed by Engineer-in-Charge. |
| 28 | M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for any description incl preparation work is necessary complete all as specified and directed by Engineer-in-Charge. |
| 29 | M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work / mass concrete for coping of poles / using at any description complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply and fix or laying in trenches / on wall / poles / structures as in repairs GItubing light grade of size 100 mm dia for road crossing / for cable protection / fixing of pigmi lights etc, of the following sizes including necessary provision for cable entry if reqd in pigmi lights pole, fixing MS nut, bolt & washers / MS clamps complete as required complete all as specified and directed by Engineer-in-Charge. |
| 31 | All as per item No. 1.29 here in before but of size 80 mm dia |
| 32 | All as per item No. 1.29 here in before but of size 50 mm dia |
| 33 | All as per item No. 1.29 here in before but of size 40 mm dia |
| 34 | Supply and fix in repairs Galvanised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl taking down / dismantling the old items complete in any sub station / installations structure complete all as specified and directed by Engineer-in-Charge. |
| 35 | S & F in repairs Pin type porcelain vitreous, brown of white insulator to suit 1100 Volt working pressure of size 100 mm height, 65mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete all as specified and directed by Engineer-in-Charge. |
| 36 | S & F in repairs Shackle typePorcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 100 mm and dia 115 mm having working pressure 1100 volts grade complete all as directed. |
| 37 | Dismantling of existing old unserviceable ACSR of any size from any description, material and labour for providing new ACSR conductor all as specified and directed incl stringing through existing RCC poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc complete of different sizes complete all as specified and directed by Engineer-in-Charge.Note : Rates for new AAC/Aluminium binding wire for binding purpose are included in the quoted rate. |
| 38 | Taking down old unsv switch air break gang operateddevice 11000 volts & supply & install Switch air break, gang operated triple pole mechanically operated mounted on 15 Nos insulator and steel frame outdoor type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post type insulator copper alloy high pressure assembly with drop out fuses operating rod of 20mm dia GI pipe medium grade for operating from 1.5m above GL, complete conforming to IS-1318 of 1972 rated voltage 11 KV and current rating 200 Amps all as specified. |
| 39 | S & F in repairs Air termination, single pointed, copper rod 12 mm dia and 300 mm long along with base incl dismantling the old complete all as specified and directed by Engineer-in-Charge. |
| 40 | S & F in repairsAir termination, single pointed aluminium rod 12 mm dia and 300 mm long with base incl dismantling the old complete all as specified and directed by Engineer-in-Charge. |
| 41 | S & F in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw in any location incl dismantling old one complete all as specified and directed by Engineer-in-Charge. |
| 42 | S & F in repairs Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors / earth continuity and down conductors above / buried in ground / run on floor / fixed on wall incl taking out old conductor complete all as specified and directed by Engineer-in-Charge. |
| 43 | All as per item No 1.41 here in before but Copper strip 20 x 3.15 mm all as specified. |
| 44 | All as per item No 1.41 here in before but Galvanised iron strip 32 x 6 mm complete all as specified and directed by Engineer-in-Charge. |
| 45 | M & L for taking down and re-fixing in repairs Aluminium strip 25 x 3.15 mm with new saddles and fixing screws etc. for roof conductors / earth continuity and down conductors above / buried in ground/run on floor / fixed on wallcomplete all as specified and directed by Engineer-in-Charge. |
| 46 | All as per item No 1.44 here in before but Copper strip 20 x 3.15 mm complete all as specified and directed by Engineer-in-Charge. |
| 47 | All as per item No 1.44 here in before but Galvanised iron strip 32 x 6 mm complete all as specified and directed byEngineer-in-Charge. |
| 48 | All as per item No 1.44 here in before but copper earth strip 32 x 6 mm complete all as specified and directed by Engineer-in-Charge. |
| 49 | M & L for new RCC poles of 9 metres long having 102 mm x 152 mm at top and 102 mm x 289 mm at bottom, class 11. complete all as specified and directed by Engineer-in-Charge. (Note : Earth work and PCC will be measured and paid separately under relevant item of this schedule) |
| 50 | M & L for Earthing complete with GI earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32 x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed by Engr-in-charge including demolish existing earth pit taking out old materials. |
| 51 | M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thickby mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engineer-in-Charge. |
| 52 | M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engineer-in-Charge. |
| 53 | Supply & Fix in repair Battery Manuel charger Unit of Rating 30 V, 20 A and AC input 230 V, 50 Hz single phase, DC output 34.5 V, 20 A including Dry type sealed maintenance free batteries rating of eachbattery 12 volt 100 AH with analog voltmeters, Ammeters etcall are fitted in suitable MS sheet enclosures hinged front operated type suitable for the operation of existing HT 33/11 KV VCB Outdoor / Indoor Panels. |
| 54 | S & F in repairs HT/LT cable route indicator standard size made out of MS disc size 4\" size with MS Flat iron fixed with two nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by Engineer-in-Charge. |
| 55 | Supply and wrapping of HT insulation tape 25 mm width in 5 mtr roll complete all as specified and directed by Engineer-in-Charge. |
| 56 | S & F in repairs lead acid battery 12 Volt 180 AH for fire detection system complete all as specified and directed by Engineer-in-Charge. |
| 57 | S & F in repairs connecting and commissioning sealed maint free battery 24 volts 80 AH. |
| 58 | M & L for removing vegetation, grass, scrubs and bushes or any small tree branches growing in Sub station yard along with fancing, around the pole, under the HT / LT transmission lines, yards or any description by mannually/mechanically and keep the sub station yard neat and clean complete all as specified and directed by Engineer-in-Charge. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid. |
| 59 | M & L for Cutting and trimming of tree branches of girth upto 150 mm dia and 3 mtr all around of any size obstructing lumination of street light/perimeter lights and touching LT/HT Over head line incl removing trimmed tree branches complete all as specified and directed by Engr-in-charge.Note ; Each cut will be measured and paid |
| 60 | S & F in repairs LT PVC line spacer suitable for existing 3 phase 4 wire OHT system complete all as specified and directed by Engineer-in-Charge. |
| 61 | S & F in repairs LT PVC line spacer suitable for existing single phase 2 wire OHT system complete all as specified and directed by Engineer-in-Charge. |
| 62 | M & L for testing of earthing value as per standard procedure for each pipe / plate / wire / any type of earthing by disconnecting the joint/lead and measuring the earth value by using suitable Tools and plants such as megger, spikes and leads in presence of Engineer-in-Charge and submitting the value to standard format in duplicate incl connecting back the leads by providing new GI nut, bolts and washers of same size complete all as specified and directed by Engineer-in-Charge.Note : The rate inclusive of make good for any damages made during testing except the following |
| 63 | M & L for cleaning the earth pit neatly by removing the vegetation/waste/dusts from the earth pit chamber by opening the chamber cover and marking of identification on the chamber cover by means of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. |
| 64 | M & L in replacement of RCC earth pit chamber cover of 50 mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways and lifting hook complete all as directed. |
| 65 | M & L in replacement of CI earth pit chamber cover of 6 mm thick of existing size, including angle iron frame for mounting of chamber cover and lifting hook complete all as specified and directed by Engineer-in-Charge. |
| 66 | S & F in repairs aluminium cable lugs eye let (Ring)/bottle neck typefor the following size of cable including cutting the existing burnt out/UNSV/damaged lugs from existing cable by taking out loop/looses cable from the position including cutting the damaged portion and preparation work and connecting to any descrption complete all as specified and directed by Engineer-in-Charge :- |
| 67 | (a)16 Sqmm cable |
| 68 | (b)25 Sqmm cable |
| 69 | (c)35 Sqmm cable |
| 70 | (d)50 Sqmm cable |
| 71 | (e)70 Sqmm cable |
| 72 | (f)95 Sqmm cable |
| 73 | (g) 120 Sqmm cable |
| 74 | (h)150 Sqmm cable |
| 75 | (i)185 Sqmm cable |
| 76 | (k)240 Sqmm cable |
| 77 | (l)300 Sqmm Cable |
| 78 | Supply & Fixin repair 25W LEDSmart Integrated Solar Street Light with Built in Mono Crystalline Panel, Lithium Ferro Phospate (LiFeP0 4 ) Battery, MPPT Charge Controller and PIR Sensor with Colour Temperature 6000-6500K. Solar Standalone Streetlight Systemof 2 days backupconsists of Solar LED Luminiare, Solar Panel, Solar maintenance Free Battery and 6 Mtr GI Pole complete all as specified and directed. Note:- Cost of suitable concrete foundation for fixing the street light pole shall be deemed to be include in the quoted rate. |
| 79 | Supply only Street light bracket made out of GI tubing 32 mm dia, light grade bend to shape of approx length 1.5mtr long suitable for security/street light fittings with necessary MS clamps - 02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers etc complete all as specified and directed by Engineer-in-Charge. |
| 80 | S & F in repairs Street light bracket made out of GI tubing 25 mm dia, light grade bend to shape of approx length 1.0 mtr long suitable for security/street light/Pigmi light fittings with necessary fixing arrangements-with one coat of red oxide and two coats of synthetic enamel paint including nut, bolt, washers etc complete all as specified and directed by Engineer-in-Charge. |
| 81 | M & L for preparation of old cement coated surface, cleaning the surface of the RCC pole of total height 9 Mtr/11 Mtr, above the ground level incl coping area (if provides) with 2 coats of ACC exterior Emulsion paint over a coat of cement primer after preparation of surface including 12 cm black paint around the polenumbers/letters in white columns complete all as specified and directed by Engineer-in-Charge. |
| 82 | S&F in repair reflective informatory sign boards box type with LED lighting, single side writing as per IRC 67 made of high intensity grade sheet, fixed over GI sheet 1/1.5 mm thick, supported on angle iron/GI pipes fixed in PCC including welding and painting /with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by Engineer-in-Charge. |
| 83 | Supply only electrical insulation rubber matingISI markedand size 1 m x 2 m x 6 mm thick complete all as specified and directed by Engineer-in-Charge. |
| 84 | Supply onlyelectrical insulation rubber matingISI markedand size 1 m x 2 m x 2 mm thick complete all as specified and directed by Engineer-in-Charge. |
| 85 | Supply only for electrical insulation rubber matingISI markedand size 1 m x 2 m x 2.5 mm thick complete all as specified and directed by Engineer-in-Charge. |
| 86 | Supply only for electrical insulation rubber matingISI markedand size 1 m x 2 m x 3 mm thick complete all as specified and directed by Engineer-in-Charge. |
| 87 | S & F in repair Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed by Engineer-in-Charge. |
| 88 | S & F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engineer-in-Charge. |
| 89 | S & F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by Engineer-in-Charge. |
| 90 | Dismantling broken / damaged pole / Struts / old concrete pole and removing from site as credit to schedule complete all as specified and directed by Engineer-in-Charge. |
| 91 | Taking out old burnt HT cable end joint and providing new HT termination jointing kit 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sq MM complete all as specified and directed by Engineer-in-Charge. |
| 92 | Taking out old burnt HT cable end joint and providing new HT termination jointing kit 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq MM complete all as specified and directed by Engineer-in-Charge. |
| 93 | Re-stretching of ACSR conductor of any size on existing HT/LT poles after loosing the winding wire upto the proper bay and winding after stretching (length of each line of wire shall be measured out horizontal distance between centre of two adjacent poles. |
| 94 | M & L forr new Prestressedconcrete pole, 11 metre long, 152x152mm at top and 152mmx260mm at bottom, class-9, erecting in truly vertical Position including numbering of poles with paint and painting upto 1.5m above ground level in black & white strips complete all as specified.(Earth work and PCC work measured and paid separately) |
| 95 | Taking down of old UNSV /Puncchered LA (Lightning arresters HT and providing new lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 KA for 11000 Volts complete all as specified & directed by Engr-in- Charge. |
| 96 | REPAIR TO JOINERY IN BLDGS AT VARUNAPURI -I, II & III, MAP AREA & MES ESTABLISHMENTS & UWR UNDER AGE B/R – II OF GE (NW) VASCO |
| 97 | Taking down chowkat / frame with shutters exc 1.5 Sqm but n exc 4 Sqm each with shutters (without taking off shutters from the frame) |
| 98 | Taking down shutter of any description n exc 1 sqm each. |
| 99 | Taking down shutter of any description exc 1 sqm and n. exc 2 sqm each. |
| 100 | Taking down chowkat or frames n exc 1.5 sqm eachand re fixing in the same opening (w/o taking of shutters from the frame).Note :The rate should be inclussive ofmaking good after refixing the door by replacing the damaged tiles or plaster. |
| 101 | Taking down chowkat or framesexc 1.5 sqm but n. exc 4 sqm and re fixing in the same opening each (w/o taking of shutters from the frame and removing to store)Note:The rate should be inclussive ofmaking good after refixing the door by replacing the damaged tiles or plaster. |
| 102 | S&F second class H.W factory made kiln seasoned, plain, solid, straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints etc complete. |
| 103 | M & L Mild steel works as in bands, straps, clamps hold fasts and similar small articles conforming to Fe 410-0 or Fe 310-0 |
| 104 | M&L for providing, cement concrete 1:2:4, type B-1 using 20mm graded stone aggregate as in bed blocks for holdfasts, roof kerbs or mud stops, roundedor chamfered on edges etc. including weathering, slightlyroundedor chamfered angles and throating as directed. |
| 105 | Forming jambs, etc. to openings incl cutting toothing and properly bonding into old works also fixing jointing and pointing / plastering to match with the existing work complete in cement mortar 1:4. |
| 106 | S & F Flush shutters, solid core construction, 30 mm thick with block board core and plywood face panels, commercial type on both sides |
| 107 | S&F second class H.W plane framed, factory made pannelled shutter 35mm thick (two pannel) with lock rail and panel of 9mm BWP commercial veneering on both faces, size of stiles and rails as per IX 1003(Part-I) kiln seasoned and chemically pressure treated. |
| 108 | S&F second class H.W 35mm thick glazed and skeleton shutters, (factory made), open rebated and prepared to receive glass guaze etc with sash bars edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc, sizes of members as specified in SSR part-I, section 8, clause 8.20(b) and fitted to chowkats. |
| 109 | S&F Aluminium alloy anodised sliding door bolt 300 mm long with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy. |
| 110 | S&Ffloor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring 150mm. |
| 111 | M&L painting to new wood and wood based surfaces of any description not otherwise described over 10cm width or girth two coats of synthetic enmel paint over a coat of pink primer including preparation of surface. |
| 112 | S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.4 mm and fixed with aluminium wire staples to wooden /steel window / ventilator shutters. |
| 113 | S&F in repairs aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.4 mm and fixed with aluminium wire staples to wooden / steel / aluminum window / ventilator shutters including wooden / aluminium beadings complete all as specified and as directed. |
| 114 | S & F aluminium anodisedbutt hinges 150mm size |
| 115 | S&F aluminium anodised barrel tower bolts of extruded section 150mm long. |
| 116 | S&F extruded aluminium alloy, fabricated type handle, anodised 150mm long |
| 117 | Taking down of aluminium window/ ventilator of any type not exc 1.5 sqm each and fixing in the same opening after repair like or replace like locking handle, rubber, rollerbeading, wire mesh, glassetc all as directed.(Note :Glass and wire mesh only will be paid separately under relevent item) |
| 118 | Taking down of aluminium window/ventilator of any type exc 1.5 sqm each and fixing in the same opening after repair like or replace like locking handle, rubber, rollerbeading , wire mesh, glassetc all as directed.(Note :Glass and wire mesh only will be paid separately under relevent item) |
| 119 | Taking down chowkat / frame with shutters n exc 1.5 Sqm (without taking off shutters from the frame) |
| 120 | Taking down chowkat / frame with shutters exc 1.5 Sqm but n exc 4 Sqm each with shutters (without taking off shutters from the frame) |
| 121 | S&F aluminium powder coated window / ventilators shutter including frame, any type (sliding or openable) with frame, & other similar work etc. fabricated by using the JINDAL / HINDAL CO / CENTURY standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium chanel beading & stainless steelscrews including the cost of rubber gasket / rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. (Note :- Wt of aluminium shall be measured exclusive of all fittings fixtures, hinges, handle, bolts, rubber gasket/rubber beading and locking arrangements.) |
| 122 | S&F aluminium powder coated grill model/design No. DG 104 (10mm thick) of make Deco grill with DL 102 frame complete all as specified and as directed. |
| 123 | M& L for painting Steel old surface of any description, over 10cm in width or girth, not otherwise described (two coat of synthetic enamal paint over a coat of primer including preparation of surface) |
| 124 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads. |
| 125 | All as per item No.28.00 above but from metal frame including punching or drilling out old glazing pins / springs or drilling out old glazing pins / spings clips and providing fixing new ones |
| 126 | S&F sheet glass ordinary quality, 4mm thick and glazing with oil putty/wooden/metal beads in squars n exc 0.5 sqm each. |
| 127 | All as per item No.30.00 above but exc. 0.5 sqm each pane. |
| 128 | All as per item No.30.00 above but with pin headed/figured glass. |
| 129 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, fixed in position as directed. The rate should be inclusive ofmaking good after fixing the door by replacing the damaged tiles or plaster and screw to fix the door. |
| 130 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with head moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rain & bottom rail panelling of plain gap insert for top rail & bottom rail paneling of plain color PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement . The thickness of PVC sheet (panel ) should not be less than 10 mm.all as perper specification & drawing and directed by Engineer In Charge. |
| 131 | All asper item No 34.00 above but wire gauzed i.e. panel will be of wire gauge in lieu of PVC sheet panel.The wire gauze shallbe wrapped on an additional square 8mm M.S. solid tube and this tube shall be welded to M.S. tube. The wire gauze shall be stretched to tighten firmly. |
| 132 | S & F aluminium anodisedbutt hinges 100mm size |
| 133 | S&F aluminium anodised barrel tower bolts of extruded section 100mm long. |
| 134 | S&F extruded aluminium alloy, fabricated type handle, anodised 100mm long |
| 135 | M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint (Ist quality) |
| 136 | Dismantling boarding, any description, fixed in any position with nails. |
| 137 | M&L 18/19 mm thick Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame workin repair. |
| 138 | M&L for PVC kitchen Cabinet (18 mm PVC oneside prelaminated sheets of Rajshri Plastiwood) complete as directed by Engineer in Charge. |
| 139 | M&L for PVC kitchen Cabinet 18 mm PVC both side plain sheets of Rajshri Plastiwood complete as directed by Engineer in Charge. |
| 140 | M&L for PVC kitchen Cabinet 12 mm PVC both side plain sheets of Rajshri Plastiwood) complete as directed by Engineer in Charge. |
| 141 | S&F 30mm wide flaps brass continous (piano) hinges |
| 142 | S&F Hasp & staple, safety type of Aluminium anodised 125mm |
| 143 | S&F curtain rails 19mm dia anodised aluminium alloy with brackets stop rollers etc fixed in repairs. |
| 144 | M & L providing Aluminium (powder coated) snap grid frame work in repair for false ceilingof grid size605 mm x 605 mm complete all as specified and as directed. |
| 145 | M & L 12mm thick mineral fibre perforated board (white) in repair, fixed with screws to aluminium snapgrid false ceiling frame work(Note: Aluminium grid shall be measured separately under relevant item of this Schedule.) |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail