Certain Repair / Replacement Of Lightening Arrestors, Flame Proof Light Fittings, Wiring And Allied Works At Itr And Lcs Area Chandipur And Pepair To Domestic Summer Appliances And Voltage Stabilizers Under Itr Chandipur, chandipur-Odisha

Military Engineer Services-MES has published Certain Repair / Replacement Of Lightening Arrestors, Flame Proof Light Fittings, Wiring And Allied Works At Itr And Lcs Area Chandipur And Pepair To Domestic Summer Appliances And Voltage Stabilizers Under Itr Chandipur. Submission Date for this Tender is 10-09-2022. Electrification Work Tenders in chandipur Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

33354749
Corrigendum : Certain Repair / Replacement Of Lightening Arrestors, Flame Proof Light Fittings, Wiring And Allied Works At Itr And Lcs Area Chandipur And Pepair To Domestic Summer Appliances And Voltage Stabilizers Under Itr Chandipur
Open Tender
Indian
Odisha
chandipur
10-09-2022

Tender Details

Certain Repair / Replacement Of Lightening Arrestors, Flame Proof Light Fittings, Wiring And Allied Works At Itr And Lcs Area Chandipur And Pepair To Domestic Summer Appliances And Voltage Stabilizers Under Itr Chandipur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Aug-2022 Corrigendum No. 01 BOQ 22-08-2022
2 22-Aug-2022 Corrigendum No. 02 Date 25-08-2022
3 24-Aug-2022 Corrigendum No. 03 Date 01-09-2022
4 27-Aug-2022 Corrigendum No. 04 Date 08-09-2022
5 06-Sep-2022 Corrigendum No. 05 Date 10-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 66000.0 /-
Tender Value
INR 33 Lakhs /-

BOQ Items

Name of Work: CERTAIN REPAIR / REPLACEMENT OF LIGHTENING ARRESTORS, FLAME PROOF LIGHT FITTINGS, WIRING AND ALLIED WORKS AT ITR AND LCs AREA CHANDIPUR AND PEPAIR TO DOMESTIC SUMMER APPLIANCES AND VOLTAGE STABILIZERS UNDER ITR CHANDIPUR
Sl. No. Item Description
1NOTE (Applicable for all items) :- The bidders/contractorsare advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE "A" PART-I (INTERNAL ELECTRIFICATION)
2Taking down / Dismantling carefully oldflame proof flood light/well glass fitting ofcapacity 80/250Watt. with connected accessories with making good dusturbed surfaces of truss, walls, floors, etc. to match with existing and all as directed.
3Supply and fixing complete FLP-WP Flood light fitting wall mounted in aluminium alloy LM6 construction of IP66 degree of protection, suitable for 120 watt LED light with lamp, driver etc, light gray epoxy powder coated 1no internal and 2 nos external earthing with SS hardware along with 2 nos 3/4" ET cable entries with suitable double compression brass nickel plated cable gland,type A toughened glass certified by CIMFR,Dhanbad for Gas Group IIC as per IS/IEC-60079&CCOE Nagpur complete all as specified and directed as per Cat no.-SSPL/FL/1251 of make-Shyam or equivalent of Bajaj/Phillips/Sudhir
4Supply and fixing complete Flame proof wellglass cum Flood light fitting Sunflower Type Ceiling and Pole MountedMounted in aluminium alloy LM6 construction of IP66 degree of protection, suitable for 150 watt LED light with lamp, driver etc, light gray epoxy powder coated 1 certified by CIMFR,Dhanbad for Gas Group IIC as per IS/IEC-60079&CCOE Nagpur complete all as specified and directed as per Cat no.-SSPL/WG/1251 of make-Shyam or equivalent ofBajaj/Phillips/Sudhir
5Taking down / dismantling old unserviceable submain wiring of any type / size and capacity.
6M&L for submain wiring with two runs of PVC insulated, unsheathed FRLSH cable with multistranded copper conductor,1100 volt gradeof size 4.0 sqmm, including one run of FRLSH grade 4.0 sqmm PVC insulated, stranded, copper conductor cable as earth wire drawn in and including flameproof ERW stove enamelled steel rigid / flexible conduit of suitable dia with bend, elbow, couplings, GI saddle clips etc and connecting up complete including taking down old unserviceable submain wiring and all as directed . (Note: Two runs of 4.0 sqmm wire and one run 4.0 sqmm FRLSH PVC cable and one run of suitable sizeERW steel conduit shall be measured as one length)
7M&L for submain wiring with two runs of PVC insulated, unsheathed FRLSH cable with multistranded copper conductor,1100 volt gradeof size 2.5 sqmm, including one run of FRLSH grade 2.5 sqmm PVC insulated, stranded, copper conductor cable as earth wire drawn in and including flameproof ERW stove enamelled steel rigid / flexible conduit of suitable dia with bend, elbow, couplings, GI saddle clips etc and connecting up complete including taking down old unserviceable submain wiring and all as directed . (Note: Two runs of 2.5 sqmm wire and one run 2.5 sqmm FRLSH PVC cable and one run of suitable sizeERW steel conduit shall be measured as one length)
8S & F flame proof rotary switches with cable in LM – 6 single pole ON- OFF 10/16 Amps make: - Shyam switch Gear Cat no-SSPL/2C/1010 or equivalent of Sudhir / BALIGA
9S & F flame proof rotary switche including socket and plug combined in LM – 6 cable termination box of capacity 16 A, 250 V, 2 P+earth complete all as specified and directed. Make: - Sudhir switch Gear Cat no-SS/OA/1010-1 or equivalent model of Shyam / Baliga.
10Taking down / dismantling old unserviceable Distribution Boards/Main Switch of any type / size and capacity.
11Supply and fixing flame proof/weatherproof distribution board TPN 8 way size 420 x 420 x 250 mm with provision of incoming MCB TPN 63 Amps- 01 No and out going SP MCB 6 to 32 Amps -12 Nos including taking out old unserviceable DB complete all as specified and directed. Cat Part No SSPL/RCP/109 of Shyaam Make or equivalent in Bajaj/L&T/Legrand
12Taking down flameproof aluminium point wiring of light, FLP power switch/socket etc. complete, includingconnected fitting and fixtures such as junction box,terminal box by unscrewing from board,metalic hose conduit (excluding flameproof luminaires,FLP rotary switches, FLP power switch/socket & plugto be measured seperately) from hangers and removing materials to store and keeping in safe custody for disposal as per credit schedule and making good dusturbed surfaces of walls, floors, etc. to match with existing and all as directed.
13M & L for flame proof point wiring with PVC insulated sheathed heat resistance, FRLSH, single core copper cable Conforming to IS-694 of size 2.5 Sqmm with stranded copper conductor drawing through flame proof ERW steel surface conduit with all fittings and accessories for connecting FLP rotary switches, light fittings & fixtures etc including 2.5 Sqmm heat resistantand fire retardantcopper conductor cable as in continuous earthing for twolight / fan pointscontrolledby one FLP rotary switch.
14Supply and fixing flameproof/weatherproof LED tube light fitting 1x 20 Watt with LED Tube rod complete including taking down old unserviceable fitting all as specified and directed.Cat Part No SSPL/FF/1271 of make -Shyaam or equivalent in Bajaj/Phillips/Sudhir
15Taking down carefully copper/aluminum point wiring (Light fan socket or power)complete including fixture and fittings such as switches, ceiling roses, pendants, regulators socket, light fittings etc removing materials for taking creditand making good disturbed surfaces of wall, floor, etc.
16M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick of size not less than 200 mm x 300 mm and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light controlled by one 5/6 amps, one way switch including all necessarywall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete allas directed and specified.
17M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick of size not less than 200 mm x 300 mm and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 5/6 amps socket outlet on independent board controlled with one, oneway switch including all necessarywall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete allas directed and specified.
18M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick of size not less than 200 mm x 300 mm and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for for one 5/6 amps socket outlet on same board controlled with other switch including all necessarywall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete allas directed and specified.
19M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 2.5 Sqmm (phase & neutral) and one run of 2.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (heavy duty) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 15/16 amps socket outlet on independent board controlled with one, 15/16 amps one way switch including all necessarywall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete allas directed and specified.
20S & FIncluding connection of switch piano, flush button, type single pole one way 5 Amps,
21S & FIncluding connection of switch socket combination 5 Amps 2 in 1 flush type,
22S & FIncluding connection of switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type
23S & Fceiling rose, polycarbonate three terminals.
24S & F Electronic fan regulator, stepped type 120/280V complete all as directed by Engineer-in-Charge.
25Taking down Sub main /Sub circuit wiring of any type and size including conduit / casing capping / batten wiring complete all as directed by Engineer-in-Charge.
26M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 4 Sqmmto be drawn in and including PVC conduit 25 mm dia (medium grade). Note:Three runs of 4 Sqmm copper wire and one run of PVC conduit shall be measured as one unit.
27M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 6 Sqmmto be drawn in and including PVC conduit 25 mm dia (medium grade). Note:Three runs of 6 Sqmm copper wire and one run of PVC conduit shall be measured as one unit.
28M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 2.50 Sqmmto be drawn in and including PVC conduit 20 mm dia (medium grade). Note:Three runs of 2.50 Sqmm copper wire and one run of PVC conduit shall be measured as one unit.
29M&L Submain wiring using six runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 10 Sqmmto be drawn in and including PVC conduit 25 mm dia (medium grade). Note:Six runs of 10 Sqmm copper wire and one run of PVC conduit shall be measured as one unit.
30Supply and fixin repair vertical TPN MCB DB 8 waywith 200 Amps rated busbar, double door type including provision for fixingMCCB 4 pole100 Amps, 25 KA complete includingtaking down old DB and making disturbed surafce good to match the existing surface.
31S & F in repairMCB DB made of sheet steel phosphatised powder coated with bus bar, neutral link, earth bar and din rail, double door type, TPN 4 way 240v, fixed in wall including making good disturbedsurfaces including taking down old unserviceable , complete all as directed by Engineer-in-Charge.
32All as per Sl Item No. 1.30 here-in-before but of SPN 8 way,240Volts double door as in repair.
33All as per Sl Item No. 1.30 here-in-before but of SPN 12 way,240Volts double door as in repair.
34S & F in repair MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 25 kA, 415 Volts, 100 Amps including taking down old unserviceable one.
35All as per Sl Item No. 1.33 above but of capacity 63 Amps, 4 Pole, 18 KA.
36S & F in repair MCB, SPN. 6-32 Amps rating 240, volt, "C" series, 10 kA,
37S & F in repair , MCB, TPN, 240V, 50Hz, 10kA, "C" series, 63 Amps series.
38S & F in repair , MCB, TP, 240V, 50Hz, 10kA, "C" series, 6 to32 Amps series.
39S & F in repair MCB, SP, 6 to 32 Amps, 240 volt, "B" Series, 10 kA, as in repairs.
40Supply and fix in repair LED down light 20 watt with aluminiu housingand provision of cutting and making space of suitable size on existing ceiling of any type complete including taking down old us fitting all as specifiedincluding complete all asdirected.
41M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate),50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. (Note :GI strip upto 7.5 m length shall be deemed to include in the cost of above item.
42All as per Sl Item No 1.40 above but using galvanised earthing lead strip of size 32mm x 6mm complete including taking out old unserviceable earthing matrials all as specified and directed by Engr-in-Charge
43All as per Sl Item No 1.41 above but using copper plate 60cm x 60cm x 3,15mm thick electrode and 20 x 3mm copper strip as earthing lead complete including taking out old unserviceable earthing matrials all as specified and directed by Engr-in-Charge
44M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised iron strip of 25 x 4mmcomplete including taking down old unserviceable strip all as specified and directed
45All as per Sl item No 1.43 above but GI strip 32 x 6mm all complete including taking down old unserviceable strip as specified and directed
46All as per Sl item No 1.43 above but copper strip 20 x 3mm complete including taking down old unserviceable strip all as specified and directed
47Taking out old Aluminium/copper strip from wall/roof top and keeping in safe custody for re-use and taking credit
48M & L for Dismantling PCC and taking out Air termination rodwith GI Pipe complete all as specified and directed
49Fixing only aluminium strip 25x3.15mm obtained from item Sl No. 46 including saddle and fixing screws and porcelein insulatorfor roof conductors and down conductors above ground.
50Fixing only copper strip 20 x 3mm obtained from item Sl No. 46 including saddle and fixing screws and porcelein insulatorfor roof conductors and down conductors above ground.
51Fixing onlysingle pointed air terminal Aluminum rod of 12mm dia and 300mm long.
52Supply and fixing of single pointed air terminal Aluminum rod of 12mm dia and 300mm long.
53S & F aluminium strip 25x3.15mm with saddle and fixing screws for roof conductors and down conductors above ground.
54SCHEDULE "A" PART-II (SUMMER APPLIANCES AND VOLTAGE STABLIZERS)
55Cleaning, servicing including carrying out preventive maintenance of summer appliances viz. indoor and out door unit ofSplit Type AC 2.0 TR using suitable cleaning solution, chemicals, tools and minor spares viz. screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. Cleaning of the condensor, evaporator, fins and cooling coils shall be done using Blower / Vacuum cleaner, cleaning clothes, nylon brushes etc till scales and dirts are removed including cleaning of drain pipe line and replacement of unserviceable spares if any and ensuring its serviceability by keeping the AC in good working condition all asspecified anddirected by Engineer-in-Charge. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as "Supplied only" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge.
56All as per Sl Item No. 2.01 above but Split Type AC 1.5 TRCapacity
57All as per Sl Item No. 2.01 above Window type AC 1.5/2 TR Capacity
58All as per Sl Item 2.01 above but for water cooler of any type, size and capacity as described below. The inner water tank of water cooler should be cleaned using bleaching powder and keeping the inner tank clean from bacteria and formation of scales and ensuring its serviceability all as specified and as directed by Engineer-in-Charge.
59All as per Sl Item 2.01 above but for refrigerator of any type, size and capacity as described below. The inner water tank of water cooler should be cleaned using bleaching powder and keeping the inner tank clean from bacteria and formation of scales and ensuring its serviceability all as specified and as directed by Engineer-in-Charge.
60Supplyonly thermostat for water cooler / refrigerator / deep freezer of any capacity and make.
61Supply only relay for any type of water cooler /refrigerator/deep freezer of any capacity & make.
62Supply only PCB suitable for split type A/C 1.5 TR capacityof any make/ model
63Supplyonly PCB suitable for split type A/C 2 TR of any make.
64Supply only Digital Display Unit suitable for split / window type A/C 1.5/ 2 TR of any make and model.
65Supply only Airsensorsuitable for split / window type A/C 1.5/2.0 TR of any make/ model
66SupplyonlyCoil sensorsuitable for window / split type A/C1.5/ 2 TR of any make/ model
67SupplyonlyRunning capacitor 45+5mfd for Window / Splittype Air conditionerof of any capacity.
68Supplyonly Running capacitor 60+5mfd for Window / Splittype Air conditionerof of any capacity.
69SupplyonlyRunning capacitor 36 mfd forair conditioner of any capacity & water cooler of any capacity
70Supply onlyRunning Capacitor capacitor 50+5 mfd for Air conditioner 2 Ton Capacity
71SupplyonlyCapacitor of 2.50 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model .
72Supplyonlycapacitor of 4.0 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model .
73Supplyonlycapacitorof 6.0 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model.
74Supplyonlyauto swing motor for indoor unit of split A/C of capacity 2/1.5 TR of any make and model to match with existing design conditions.
75Supplyonly Power contactor suitable for Split AC of 3.0 TR capacityof any make and model to match with existing design conditions.
76SupplyonlyBrass angle valveof size 5/8 inch for split AC 1.5/2TR capacity.
77Supplyonly Brass angle valve 1/4 inch for split AC 1.5/2TR capacity.
78Supplyonly Brass angle valve 1/2 inch for split AC 1.5/2TR capacity.
79Supply onlyNitrile Foam Insulation for copper tube of size 5/8 inch suitable for split AC including provision of requisite PVC fasteners.
80Supply onlyNitrile Foam Insulation for copper tube of size 1/4 inch suitable for split AC including provision of requisite PVC fasteners..
81SupplyonlyNitrile Foam Insulation for copper tube of size 1/2 inch suitable for split AC including provision of requisite PVC fasteners..
82SupplyonlyPVC ball valves / float valve for water cooler of any capacity & make
83Supplyonlybrass chromium plated push button tap outer / Inner thread ISI markedsuitable for water cooler of any type of size 15 mm.
84Supplyonly Thermostat for Window AC of capacity 1.5 TR/2.0 TR to match with existing design conditions.
85Supplyonlyrelayof model 1622Y suitable for Window type ACof any capacity and to match with existing design conditions..
86Supplyonly in repairSelector Switch for window type AC and to match with existing design conditions..
87SupplyonlyOver load relayof16 Amps capacity suitable for Window type ACof any capacity and to match with existing design conditions..
88Supplyonly Remote Universal type suitable for all type of split / window AC of any make and model or any capacity and to match with existing design conditions..
89SupplyonlyPVC Drain pipe of size1/2" size suitable for Split type AC of any capacity.
90Supplyonly , mainDrain pipe of indoor unitof size 3/4 ", PVC Flexible type suitable for Split type ACof any capacity.
91SupplyonlyRubber Bush for Fan Motor of out door unit of split type AC and Window type AC of any capacityandany make and model .
92Supplyonly Flairing Nuts of Size 5/8 for out door unit of Split type AC of Any make and model.
93Supplyonly Flairing Nuts of Size 1/2 for out door unit of Split type AC of Any make and model.
94Supplyonly Flairing Nuts of Size 1/4 for out door unit of Split type AC of Any make and model.
95Taking out unserviceable Receprocating type compressor of Window /Split Type AC 1.5 Ton capacity, from site and replacement of compressor withnew oneto match with existing make/Model (R Compressor) and fixingof new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a as per existing design of AC, brazing of discharge andsuction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
96Taking out unserviceable Receprocating type compressor of Window /Split Type AC 2 Ton capacity, from site and replacement of compressor withnew oneto match with existing make/Model (R Compressor) and fixingof new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a as per existing design of AC, brazing of discharge andsuction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
97Taking out unserviceable Rotary type compressor of Window/ Split Type AC 1.5 Ton capacity, from site and replacement of compressor withnew oneto match with existing make/Model (R Compressor) and fixingof new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a as per existing design of AC, brazing of discharge andsuction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
98Taking out unserviceable Rotary type compressor of Window/ Split Type AC 2 Ton capacity, from site and replacement of compressor withnew oneto match with existing make/Model (R Compressor) and fixingof new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a as per existing design of AC, brazing of discharge andsuction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
99M/L for Gas charging with R-22 refrigerant gasforSplit / Windows ACs of any make, model and capacity, Refrigerator and Water coolersof any make, Modelof any capacity in positionor by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging.
100M/L for Gas charging with R-407/R-410/R-410A refrigerant gasforSplit / Windows ACs of any make, model and capacity, Refrigerator and Water coolersof any make, Modelof any capacity in positionor by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging.
101Taking down unserviceable Fan Motorof Window / Split type AC1.5/2.0 TR capacity and of any make and model, removing burnt winding, insulation material, cleaning the surfaces,rewindingthe motor with super enameled copper winding wire of same gauge and size including insulation material and varnishingand re-fixing at site all as directed by Eng-in-Charge.
102Supplyand fixing in repair Blower Fan motor assembly of indoor unit of split AC 1.5/2TR of any make and model and all as directed.
103Taking down unserviceable Condenser fanmotor of water cooler/refrigerator/deep freezer of any capacity, make and model, removing burnt winding, insulation material, cleaning the surfaces,rewindingthe motor with super enameled copper winding wire of same gauge and size including insulation material and varnishingand re-fixing at site all as directed by Eng-in-Charge.
104Supply and fixing in repairCondenser Fan motor ISI markedof window/split Ac of any make and capacityand water cooler of any capacity, make and model and all as directed.
105Supply and fixing in repair,Out door Bracket ISI marked suitable for fixingout door unit of Split type ACs of any make and capacity along with MS clamps, bracings, supports, bolts, nuts & washers, PVC rawl plug etc and making good disturbed surface of wall in CM 1:3 including painting to match with existing surface and all as directed.
106Supplyand fixing in repair Condenser Fan Blademarkedsuitable for 1.5 /2 Ton Split Type Air conditionerof any make and model and all as directed.
107Supply and fixing in repair Fan Blade suitable for Water Cooler of any capacity / Make and model and all as directed.
108Taking down existing split type AC indoor and outdoor units complete of any make / capacity after disconnecting all accessoriesand Refixing at a different location including making necessary fixing arrangements, after carrying out necessary maintenance / servicing including testing on load at site completeall as specified and directed by Engineer - in- charge . Note:-vacuuming / Gas Charging / spares parts etc if required will be measured and paid seperately under revelent Items of schedule of works .
109M/L for carrying out spray painting completeunit of window type AC of anymake, modeland capacity after dismantling, and paintingon sheet metal enclosers interanally andexternally with twocoats of syntheticenamel paint of approved make and shade after preparation of surface and writing the MES/SM Nos, re-assembling and reconnecting the AC unit at its installed location complete all as directed.
110All as per Sl item No. 2.57 above but for outdoor unit of split AC of any capacity make and model.
111Supply and fixing in repair Copper Condenser CoilISI marked suitable for Window type AC of 1.5TRcapacityof any make and model to match with existing design conditions.
112Supply and fixing in repair Copper Condesser CoilISI marked suitable for Window type AC of 2.0 TRcapacityof any make and model to match with existing design conditions.
113Supply and fixing in repair Copper Condesser CoilISI marked suitable for Split type AC of1.5 /2.0TRcapacityof any make and model to match with existing design conditions.
114Supply and fixing in repair Cooling Coilsuitable ISI markedfor Windowtype AC of1.5 TRcapacityof any make and model to match with existing design conditions.
115Supply and fixing in repair CoolingCoilISI marked suitable for Window type AC of2.0TRcapacityof any make and model to match with existing design conditions.
116M &L forSub main wiring inPVC conduit of required size 2 runof6 sqmm PVC insulated copper conductor cable wih onerun of 4 sqmm PVC insulated copper conductor cable as continuity earth wire, including taking down existing old unsv point wiring ,all as speified and directed .
117Supply andfixing in repair 4 Core 4 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for AC / water cooler / Refrigerator / AC / Voltage stabilizer.
118Supply and fixing in repair Electronic Circuit Board Suitable for Out door unit ofSplit type AC 1.5/2.0 TR(Voltas Inverter model ) and all as per Existing make and model , All as specified and directed by Engr - in - Charge
119Supply and Replace compressorfor water cooler40/80 Ltr capacity and assembling and resting the compressor unit complete all as directed by Engineer- in -charge.including taking down, Make : DANFOSS/ LG/ Tecumseh.
120Repair to body of water cooler by providing MS sheet 2mm thick including welding, replacement of wornout nuts & bolts and repair/fabrication of the compressor mounting base as per existing fabrication work including all as directed and specified ( Approx area of MS Sheet 0.75 Sqmtrs) and painted by two coats of synthetic enameled paint of existing cooler over a coat of red oxide primer.
121Supply and fixing in repair Electronic Circuit Board Suitable for Indoor unit ofSplit type AC 1.5/2.0 TR(Voltas Inverter model ) and all as per Existing make and model , All as specified and directed by Engr - in - Charge
122Supply and fixing in repair /replacement of MCB Protected Power unit comprising of suitable capacity SPN MCB, 3 pin Socket and On/Off Motor Starter suitable for controlling AC and includingmaking good to existing disturbed works completete all as directed and specified, and taking down old unserviceable plug socket for offering credit.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail