Procurement Erection And Commissioning Of Ph Transmitters, Conductivity Transmitters With Sensors In Dm Plant , Dual Channel Analyzer, Ph / Conductivity With Two Sensors, Ph Sensormodel::Fm1104, 240Vac:Output Signal:2X4-20Ma:Or Its Equivalentph / Cond
Tender Overview
Project Description
Procurement Erection And Commissioning Of Ph Transmitters, Conductivity Transmitters With Sensors In Dm Plant , Dual Channel Analyzer, Ph / Conductivity With Two Sensors, Ph Sensormodel::Fm1104, 240Vac:Output Signal:2X4-20Ma:Or Its Equivalentph / Conductivity Dual Channel Analyzer With Two Ph Sensors As A Set: Ph And Conductivity Preferably Selectable To Any Channel Via Software: Accuracy And Repeatability:+ / -1%Fsdand Plus / Minus3% Range: ( 0-14 ) Ph: Ma Accuracy:+ / - 0.1 Ma:, 240 V Ac Supply, Monitor Enclousre:Ip65:Ambient Temperature:55Degc: Output Signal: 2X4-20 Ma Galvanically Isolated: Local Indication: Lcd: Dimensions: Bezel 144X144x150 ( D ) , Cutout:138X138 Mm: Sample Flow Rate: ( 5-8 ) Lphcalibration Type : 2-Point, Analyzer Should Be Universal And Suitable For Any Type Of Ph Sensors, Warranty Should Be Minimum Three Years.Sensor Details: Equivalent Model And Should Be Compatible To Insert In Housing Of Hamilton Liq-Glass Pg Sensor With Following Details: Ph Range ( 0-14 ) :Pt 100: Maximum Temp 80 Deg: Maximum Pressure 2 Bar: Electrical Connection :As7 Connection Head :Process Connection:Pg13.5 Threads: Sensor Length 120Mm, Dia:12Mm, Cable And Sensor Preferably Detachable Type. Cable Length :5 Mtrsnote: Both Channels Should Be Configured To Ph Onlynote: Including Erection Commissioning Work., Dualchannel Analyzer, Conductivity / Ph With Two Sensors:K Is Equal To 0.01, 240V Ac :Ooutput Signal:2X4-20Maconductivity / Ph Dual Channel Analyzer With Two Sensors : Conductivity And Ph Preferably Selectable To Any Channel Via Software: Accuracy And Repeatability:Plus / Minus1 Percent Fsd And Plus / Minus 3Percent Range: ( 0.01-200 ) Micros / Cm And ( 0.1-2 ) Ms / Cm And ( 1-20 ) Ms / Cm: Ma Accuracy: Plus / Minus 0.1 Ma: Type And No Of Contacts:2 Relay Contacts Inbuilt, 240 V Ac, Monitor Enclousre:Ip65:Ambaint Temperature:55Degc:Temprature Compensation: Automatic Throughout Operating Range Provided By Pt-100: Output Signal: 2X4-20 Ma Galvanically Isolated: Local Indication: Lcd: Dimensions: Bezel 144X144x150 ( D ) , Cutout:138X138 Mm: Sample Flow Rate: ( 5-8 ) Lphcalibration Type:Electric, 2 Points And 1Point.Analyzer Selectable To Any K ( 0.01, 0.1, 1 ) Value Via Software.Warranty Should Be Minimum Three Years.Sensor Details: Polymetron 8310 Or Its Equivalent With Following Details: K Is Equal To 0.01 :Pt 100 Temperature Response Lessthan30 Seconds: Maximum Temp 125 Deg: Maximum Pressure 10 Bar: Sample Connection :3 / 4 Inch Npt: Cable And Sensor Preferably Detachable Type. Cable Length :5 Mtrsnote: Both Channels Should Be Configured To Conductivity Onlynote: Including Erection Commissioning Work
BOQ
| Sl. No. | Item Name |
| 1 | DUAL CHANNEL ANALYZER,PH/CONDUCTIVITY WITH TWO SENSORS, PH SENSORMODEL::FM1104,240VAC:OUTPUT SIGNAL:2X4-20MA:OR ITS EQUIVALENTpH/ Conductivity Dual channel Analyzer with two pH sensors as a set: pH and Conductivity preferably Selectable to any channel via Software: Accuracy and repeatability:+/-1%FSDand plus/minus3% Range:(0-14) pH: mA accuracy:+/- 0.1 mA:,240 V AC supply, Monitor Enclousre:IP65:Ambient temperature:55degC: Output signal: 2X4-20 mA Galvanically isolated: Local indication: LCD: Dimensions: BEZEL 144X144X150(D),Cutout:138X138 MM: Sample flow rate:(5-8)LPHCalibration Type : 2-point, Analyzer should be universal and suitable for any type of Ph sensors, Warranty should be minimum Three Years.Sensor Details: Equivalent model and should be Compatible to insert in housing of HAMILTON Liq-Glass PG sensor with following details: Ph range(0-14) :PT 100: Maximum temp 80 deg: Maximum Pressure 2 bar: Electrical Connection :AS7 connection head :Process Connection:PG13.5 threads: Sensor Length 120mm,Dia:12mm, Cable and sensor preferably detachable type. Cable Length :5 MtrsNote: Both channels should be configured to pH onlyNote: Including Erection Commissioning work. |
| 2 | DUALCHANNEL ANALYZER,CONDUCTIVITY/PH WITH TWO SENSORS:K is equal to 0.01,240V AC :OOUTPUT SIGNAL:2X4-20MAConductivity/pH Dual channel Analyzer with two sensors : Conductivity and pH preferably Selectable to any channel via Software: Accuracy and repeatability:plus/minus1 percent FSD and plus/minus 3percent Range:(0.01-200) MicroS/cm and(0.1-2) mS/cm and(1-20)mS/cm: mA accuracy: plus/minus 0.1 mA: Type and No of contacts:2 Relay contacts inbuilt, 240 V AC, Monitor Enclousre:IP65:Ambaint temperature:55degC:Temprature Compensation: Automatic throughout operating range provided by PT-100: Output signal: 2X4-20 mA Galvanically isolated: Local indication: LCD: Dimensions: BEZEL 144X144X150(D),Cutout:138X138 MM: Sample flow rate:(5-8)LPHCalibration Type:Electric, 2 points and 1point.Analyzer Selectable to any K (0.01, 0.1, 1) value via software.Warranty should be minimum Three Years.Sensor Details: Polymetron 8310 or its equivalent with following details: k is equal to 0.01 :PT 100 temperature response lessthan30 seconds: Maximum temp 125 deg: Maximum Pressure 10 bar: Sample Connection :3/4 inch NPT: Cable and sensor preferably detachable type. Cable Length :5 MtrsNote: Both channels should be configured to Conductivity onlyNote: Including Erection Commissioning work |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Completed