Development Of Distribution Infrastructure Kanpur Zone Development Of , kanpur-Uttar Pradesh

Dakshinanchal Vidyut Vitran Nigam Limited-DVVNL has published Development Of Distribution Infrastructure Kanpur Zone Development Of . Submission Date for this Tender is 30-08-2022. Infrastructure Work Tenders in kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33337365
Corrigendum : Development Of Distribution Infrastructure Kanpur Zone Development Of
Open Tender
Indian
Uttar Pradesh
kanpur
30-08-2022

Tender Details

Development Of Distribution Infrastructure Kanpur Zone Development Of

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Aug-2022 Corrigendum_1 Technical Bid 21-08-2022
2 18-Aug-2022 Corrigendum_2_Revised_Form-21 Technical Bid 21-08-2022
3 18-Aug-2022 Corrigendum_2 Technical Bid 21-08-2022
4 20-Aug-2022 Date Extension-VII Date 30-08-2022

Key Value

Document Fees
INR 29500 /-
EMD
INR 50000000.0 /-
Tender Value
INR 699.56 Crore /-

BOQ Items

Name of Work: Development of Distribution Infrastructure at KANPUR Zone ( Electricity Distribution Circle- EDC Etawah, EDC Auraiya, EDC Kannauj, EDC Farrukhabad, EDC Kanpur Nagar and EDC Kanpur Dehat), District - Etawah, Auraiya, Kannauj, Farrukhabad, Kanpur Nagar andKanpur Dehat of UTTAR PRADESHState under the Revamped Reforms-based and Results-linked, Distribution Sector Scheme
Sl. No. Item Description
1SUPPLY OF ITEMS
28.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
39 Meter long STP as per Approved Drawing and Technical specification (SP-33)
411 Meter long STP as per Approved Drawing and Technical specification (SP-55)
513 Meter long STP as per Approved Drawing and Technical specification (SP-72)
6Stone Pad (300x300x75mm)
71 core (Al.) 120mm2 LT Armoured XLPE Cable
81 core (Al.) 95mm2 LT Armoured XLPE Cable
91 core (Al.) 50mm2 LT Armoured XLPE Cable
101 core (Al.) 25mm2 LT Armoured XLPE Cable
1111 kVXLPE Cable 3x185 Sq. mm. (Armoured)
121x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes.
131x25 mm2 Armoured XLPE insulated Al. LT Cable for energising the distribution boxes.
14Armoured Service Cable 2CX4 SQMM For Single phase consumer for upto 2KW
15Armoured Service Cable 2CX6 SQMM For Single phase consumer for above 2 and upto 4 KW
16Armoured Service Cable 4CX10 SQMM For Three phase consumer for upto 10kW
17Armoured Service Cable 4CX16 SQMM For Three phase consumer for upto 25kW
18Aerial Bunched XLPE Cable 3X120 (Ph) + 1X95 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm
19Aerial Bunched XLPE Cable 3X50 (Ph) + 1X35 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm
20Aerial Bunched XLPE Cable 3X95 (Ph) + 1X70 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm
21Aerial Bunched XLPE Cable 1X16 (Ph) + 1X25 ( Bare messenger cum neutral) sqmm
22LT XLPE cable 3.5x150 Sq mm
23LT XLPE cable 3.5x70 Sq mm
24LT XLPE cable 4x16 Sq mm
25L.T. XLPE cable 10 Sq. mm Single Core
26LT XLPE cable 3.5x400 Sq mm
27ACSR Rabbit Conductor
28Aluminium binding wire - 6 SWG
29Jointing sleave -ACSR Rabbit
30Mid Span Joint 120mm2
31ACSR Rabbit Conductor -Jumpering Works
32ACSR Weasel Conductor-Jumpering Works
3311 KV Danger Board with Clamp and Nuts & Bolts
3411 KV Number Plate with Clamp and Nuts & Bolts
3511KV Fuse Set (Drop out) with clamps
3611KV TPMO with fixing clamps
3710 KVA, 11KV/250 V, 1 Ph Transformer (Level-1 Self Protected Aluminium Wound Type)
3816 KVA, 11KV/250 V, 1 Ph Transformer (Level-1 Self Protected Aluminium Wound Type)
3925 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type)
4063 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type)
41100 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type)
42LT Distribution Box withMCCB for protection of 10 KVA T/F and Bus Bar foroutgoing consumer connections with Energy Meter (SMC Type) as per TS. (DRG- no.REC/RDSS/DTR/SS/20 )
43LT Distribution Box withMCCB for protection of 16 KVA T/F and Bus Bar foroutgoing consumer connections with Energy Meter (SMC Type) as per TS.( DRG- no. REC/RDSS/DTR/SS/20 )
44LT Distribution Box withMCCB and AMI metering (Smart Meter compitable with System) equipment & fixing arrangement As per TS . (SMC Type) for 25KVA (DRG- no. REC/RDSS/DTR/SS/24)
45LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/16) equipment & fixing arrangement As per TS . (SMC Type) for 63 KVA (DRG- no. REC/RDSS/DTR/SS/23)
46LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/23) equipment & fixing arrangement As per TS . (SMC Type) for 100KVA (DRG- no. REC/RDSS/DTR/SS/23)
47LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/23) equipment & fixing arrangement as per TS. (SMC Type) for 250KVA (DRG- no. REC/RDSS/DTR/SS/22)
48Copper L-Piece 50x225x10mm
49Copper L-Piece 50x225x12mm
50Al Lug long barrel off size
519 KV LA , 5 KA (Distribution Class)
529 KV LA , 10 KA (Station Class)
53Earthing Coil connected with nutbolt using Charchol and Salt
54GI Flat 50X6 for Earthing
55GI Flat 25X3 for Earthing
56Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc.
57GI Pipe 6" Diameter with clamps
58G.I. Barbed Wire
59G.I. Wire No. 16 SWG for binding
60G.I. Wire 6 SWG
61G.I. Wire 8 SWG
6211 KV Disc Fitting T & C type
6311 KV Polymer Disc Insulators45 KNT&C Type
6411 KV Pin Insulator Polymer Type as per TS
6533 KV Composit Pin Insulator (Polymer Type)
66LT Shackle Insulator
67Insulating Piercing Connector (50-150 sq.mm)
68Insulating Piercing Connector (16-150 sq.mm)
69Dead End clamp (Insulated)
70End Cap for AB cable
71Suspension clamps (Insulated)
72Pole Clamps with with I-Hook & nut & bolts for laying ABC
73SS Strips As per Drg -REC/RDSS/LT-ACC-ABC/01
74Dead End assembly unit as Per Drg-REC/RDSS/LT-ACC-ABC/03
75Suspension assembly unit as Per Drg- REC/RDSS/LT-ACC-ABC/
76D-Straps
77Insulation mastic tape (2inc X 10 feet).
78Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with clamps (40x3 mm) and nut & bolts
79Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with clamps (40x3 mm) and nut & bolts
80Aluminium paint
81Red Oxide Paint
82Smart TVM Meter Compatible with System (AMI) complete Set
83HDPE Pipe, PN-4 PE-80(160 mm dia.) with clamp, etc
84Crimping type heavy duty aluminium lugs suitable for connection XLPE cables
85Helical formed Fitting
86Cable Route Marker
87PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral)
88PG Clamp for Rabbit
89GI Stay Wire 7/10 SWG
90GI Stay Wire 7/8 SWG
91HT Guy Insulator
92LT Guy Insulator
9333 KV Stay Complete (GI Stay Rod 20x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers
94Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
95Turn Buckle
96HT Stay Clamp as per approved drawing-33 KV
97HT Stay Clamp as per approved drawing-11 KV
98LT Stay Clamp as per approved drawing
9911 KV Cross arm holding clamps with bolts & nuts
10011 KV Steel X-arm V type (GI Channel 65X 65 X 6 mm )
10133 KV Cross arm holding clamps with bolts & nuts
10233 KV Steel X-arm V type (GI Channel 100 X 50 X 6 mm )
103Angle for vertical ArmL50x50x6 (Type -A)-900MM
104Angle for vertical ArmL50x50x6 (Type -B)- 900MM
105Top Clamp for Vertical arm L 50X6 (Type -A)- 435 mm
106Top Clamp for Vertical arm L 50X6 (Type -B)- 435 mm
107Bottom Clamp for Vertical arm L 50X6 (Type -A)- 507 mm
108Bottom Clamp for Vertical arm L 50X6 (Type -B)- 507 mm
109Clamp FOR Top Channel with Nut bolt
110Clamps for LT T-off with bolts & nuts
111E- Bracket for 11 KV line
112Eye Bolt
113F- Bracket for 11 KV line
114F- Bracket for 33 KV line
115Guarding angle 65x55x6 mm, 1.6 mtr. With Clamp
116Holding clamps for Top channel, GI Channel & GI Angle with bolts & nuts
117GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M)
118GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps
119GI Channel 100x50x6 mm 2028 mm long (For Fuse Set )
120GI Top channel 125x65x6 mm., 2240 mmlong
121Tee-off Channel 100x50x1300 mm with clamp, Nut & Bolt
122Clamps for Dist. Box (40x6 mm)
123Clamps for T/F (75x8 mm GI flat).
124GI. guarding Angle 75x75x6 mm 3010 mm long with Clamp
125Height raising channel 100x50,2240 mm long
126Back clamp for Height raising channel holding clamps with bolts & nuts
127GI Channel clamp with nuts & bolts
128GI Channel 125x65 mm
129GIangle 75x75x6x2028 mm with clamp &bolt and nut (T/F base)
130GI Channel 75x75x6 mm &bolt and nut (T/F base Support)
13111 KV, 1250 A Outgoing VCB Indoor type with CTR 200/100/5 - 5A 350 MVA (Compatible with existing VCB at 33/11 KV substation)
132Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable
133Heat Shrinkable Jointing Kit indoor for 11 KV 3x185 sq. mm XLPE Cable
134Cable jointing kit straight through (3x185)
135Extra Prefabricated Items Like Clamp , Channel, Angle with Nut bolt
136Satellite Multi-Tap Connector as per TS
137Sign Board as per TS and Approved Drawing
138ERECTION PART
139Conversion of existing Service Cable to New Armoured Service cable with all required accessories like lugs etc. (Complete Work in all respect) and Removing and shifting of Existing Material to client store
140Armoured Service Cable 2CX4 SQMM For Single phase consumer for upto 2KW
141Armoured Service Cable 2CX6 SQMM For Single phase consumer for above 2 and upto 4 KW
142Armoured Service Cable 4CX10 SQMM For Three phase consumer for upto 10kW
143Armoured Service Cable 4CX16 SQMM For Three phase consumer for upto 25kW
144Erection, Testingand commissioning of Replacement ofLT Bare Conductor with AB Cables (Complete Work in all respect)
1458.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
1469 Meter long STP as per Approved Drawing and Technical specification (SP-33)
147Stone Pad (300x300x75mm)
148Aerial Bunched XLPE Cable 3X120 (Ph) + 1X95 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm
149Aerial Bunched XLPE Cable 3X95 (Ph) + 1X70 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm
150Aerial Bunched XLPE Cable 3X50 (Ph) + 1X35 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm
151Pole Clamps with with I-Hook & nut & bolts for laying ABC
152Dead End clamp (Insulated)
153Suspension clamps (Insulated)
154SS Strips As per Drg -REC/RDSS/LT-ACC-ABC/01
155Dead End assembly unit as Per Drg-REC/RDSS/LT-ACC-ABC/03
156Suspension assembly unit as Per Drg- REC/RDSS/LT-ACC-ABC/
157End Cap for AB cable
158Insulating Piercing Connector (16-150 sq.mm)
159PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral)
1601x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes.
161Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with clamps (40x3 mm) and nut & bolts
162Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with clamps (40x3 mm) and nut & bolts
163Earthing Coil connected with nutbolt using Charchol and Salt
164Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
165LT Guy Insulator
166GI Stay Wire 7/10 SWG
167LT Stay Clamp as per approved drawing
168Removing and shifting of Existing Material to client store
169Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing
170Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.39 Cmt (9 Meter - STP ) as per approved Drawing
171Erection, Testingand commissioning of Replacement ofAB Cable (Damage)with AB Cables (Complete Work in all respect)
1728.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
1739 Meter long STP as per Approved Drawing and Technical specification (SP-33)
174Stone Pad (300x300x75mm)
175Aerial Bunched XLPE Cable 3X120 (Ph) + 1X95 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm
176Aerial Bunched XLPE Cable 3X95 (Ph) + 1X70 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm
177Pole Clamps with with I-Hook & nut & bolts for laying ABC
178Dead End clamp (Insulated)
179Suspension clamps (Insulated)
180SS Strips As per Drg -REC/RDSS/LT-ACC-ABC/01
181Dead End assembly unit as Per Drg-REC/RDSS/LT-ACC-ABC/03
182Suspension assembly unit as Per Drg- REC/RDSS/LT-ACC-ABC/
183End Cap for AB cable
184Insulating Piercing Connector (16-150 sq.mm)
185PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral)
1861x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes.
187Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with clamps (40x3 mm) and nut & bolts
188Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with clamps (40x3 mm) and nut & bolts
189Earthing Coil connected with nutbolt using Charchol and Salt
190Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
191LT Guy Insulator
192GI Stay Wire 7/10 SWG
193LT Stay Clamp as per approved drawing
194Removing and shifting of Existing Material to client store
195Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing
196Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.39 Cmt (9 Meter - STP ) as per approved Drawing
197Erection, Testingand commissioning of Replacement of LT Line with XLPE Armoured Cables (Complete Work in all respect)
1988.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
1999 Meter long STP as per Approved Drawing and Technical specification (SP-33)
200Stone Pad (300x300x75mm)
201Angle for vertical ArmL50x50x6 (Type -A)-900MM
202Top Clamp for Vertical arm L 50X6 (Type -A)- 435 mm
203Bottom Clamp for Vertical arm L 50X6 (Type -A)- 507 mm
204Angle for vertical ArmL50x50x6 (Type -B)- 900MM
205Top Clamp for Vertical arm L 50X6 (Type -B)- 435 mm
206Bottom Clamp for Vertical arm L 50X6 (Type -B)- 507 mm
207LT Shackle Insulator
208D-Straps
2091 core (Al.) 120mm2 LT Armoured XLPE Cable
2101 core (Al.) 95mm2 LT Armoured XLPE Cable
2111 core (Al.) 50mm2 LT Armoured XLPE Cable
2121 core (Al.) 25mm2 LT Armoured XLPE Cable
213Mid Span Joint 120mm2
214Insulating Piercing Connector (50-150 sq.mm)
215Insulation mastic tape (2inc X 10 feet).
216Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with clamps (40x3 mm) and nut & bolts
217Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with clamps (40x3 mm) and nut & bolts
218Satellite Multi-Tap Connector as per TS
2191x25 mm2 Armoured XLPE insulated Al. LT Cable for energising the distribution boxes.
220Earthing Coil connected with nutbolt using Charchol and Salt
221Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
222LT Guy Insulator
223GI Stay Wire 7/10 SWG
224LT Stay Clamp as per approved drawing
225Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing
226Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.39 Cmt (9 Meter - STP ) as per approved Drawing
227Removing and shifting of Existing Material to client store
228Survey , Erection, Testingand commissioning of 11 Kv Line (Feeder Spliting Due to over loading) on 8.5 Mtr PCC pole-916 CKM and 11 Mtr STP Pole -222 CKM (Complete Work in all respect)
229Route survey and pole spotting for 11 KV line
2308.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
23111 Meter long STP as per Approved Drawing and Technical specification (SP-55)
232ACSR Rabbit Conductor
233Stone Pad (300x300x75mm)
23411 KV Steel X-arm V type (GI Channel 65X 65 X 6 mm )
23511 KV Cross arm holding clamps with bolts & nuts
236F- Bracket for 11 KV line
237GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M)
238Clamp FOR Top Channel with Nut bolt
239GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps
240E- Bracket for 11 KV line
24111 KV Pin Insulator Polymer Type as per TS
24211 KV Polymer Disc Insulators45 KNT&C Type
24311 KV Disc Fitting T & C type
244PG Clamp for Rabbit
245Aluminium binding wire - 6 SWG
246Jointing sleave -ACSR Rabbit
24711 KV Danger Board with Clamp and Nuts & Bolts
248G.I. Barbed Wire
249Aluminium paint
250Red Oxide Paint
251Earthing Coil connected with nutbolt using Charchol and Salt
252Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
253HT Guy Insulator
254GI Stay Wire 7/10 SWG
255HT Stay Clamp as per approved drawing-11 KV
25611 KV Number Plate with Clamp and Nuts & Bolts
257Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing
258Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing
259Erection, Testingand commissioning of 11 KV VCB with complete Assoceries as apporoved Drawing and Tecchanical Specifiactions (Complete Work in all respect)
26011 KV, 1250 A Outgoing VCB Indoor type with CTR 200/100/5 - 5A 350 MVA (Compatible with existing VCB at 33/11 KV substation)
26111 kVXLPE Cable 3x185 Sq. mm. (Armoured)
262Heat Shrinkable Jointing Kit indoor for 11 KV 3x185 sq. mm XLPE Cable
263Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable
264Smart TVM Meter Compatible with System (AMI) complete Set
265Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc.
266GI Flat 50X6 for Earthing
2678.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
268Stone Pad (300x300x75mm)
269GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M)
270Clamp FOR Top Channel with Nut bolt
271GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps
27211 KV Polymer Disc Insulators45 KNT&C Type
27311 KV Disc Fitting T & C type
274PG Clamp for Rabbit
27511 KV Danger Board with Clamp and Nuts & Bolts
276G.I. Barbed Wire
277Earthing Coil connected with nutbolt using Charchol and Salt
278Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
279HT Guy Insulator
280GI Stay Wire 7/10 SWG
281HT Stay Clamp as per approved drawing-11 KV
282Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing
283Survey , Erection, Testingand commissioning of 11 Kv Line (Feeder Sagrigation) (Complete Work in all respect)
284Route survey and pole spotting for 11 KV line
2858.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
286ACSR Rabbit Conductor
287Stone Pad (300x300x75mm)
28811 KV Steel X-arm V type (GI Channel 65X 65 X 6 mm )
28911 KV Cross arm holding clamps with bolts & nuts
290F- Bracket for 11 KV line
291GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M)
292Clamp FOR Top Channel with Nut bolt
293GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps
294E- Bracket for 11 KV line
29511 KV Pin Insulator Polymer Type as per TS
29611 KV Polymer Disc Insulators45 KNT&C Type
29711 KV Disc Fitting T & C type
298PG Clamp for Rabbit
299Aluminium binding wire - 6 SWG
300Jointing sleave -ACSR Rabbit
30111 KV Danger Board with Clamp and Nuts & Bolts
302G.I. Barbed Wire
303Earthing Coil connected with nutbolt using Charchol and Salt
304Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
305HT Guy Insulator
306GI Stay Wire 7/10 SWG
307HT Stay Clamp as per approved drawing-11 KV
30811 KV Number Plate with Clamp and Nuts & Bolts
309Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing
310Extra Prefabricated Items Like Clamp , Channel, Angle with Nut bolt
311Erection, Testingand commissioning of 11 KV VCB with complete Assoceries as apporoved Drawing and Tecchanical Specifiactions(Feeder Segrigation) (Complete Work in all respect)
31211 KV, 1250 A Outgoing VCB Indoor type with CTR 200/100/5 - 5A 350 MVA (Compatible with existing VCB at 33/11 KV substation)
31311 kVXLPE Cable 3x185 Sq. mm. (Armoured)
314Heat Shrinkable Jointing Kit indoor for 11 KV 3x185 sq. mm XLPE Cable
315Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable
316Smart TVM Meter Compatible with System (AMI) complete Set
317Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc.
318GI Flat 50X6 for Earthing
3198.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
320Stone Pad (300x300x75mm)
321GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M)
322Clamp FOR Top Channel with Nut bolt
323GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps
32411 KV Polymer Disc Insulators45 KNT&C Type
32511 KV Disc Fitting T & C type
326PG Clamp for Rabbit
32711 KV Danger Board with Clamp and Nuts & Bolts
328G.I. Barbed Wire
329Earthing Coil connected with nutbolt using Charchol and Salt
330Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
331HT Guy Insulator
332GI Stay Wire 7/10 SWG
333HT Stay Clamp as per approved drawing-11 KV
334Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing
335Erection, Testingand commissioning of 11 KV NH Crossing (Complete Work in all respect)
33611 kVXLPE Cable 3x185 Sq. mm. (Armoured)
337Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable
338HDPE Pipe, PN-4 PE-80(160 mm dia.) with clamp, etc
339GI Pipe 6" Diameter with clamps
34011 Meter long STP as per Approved Drawing and Technical specification (SP-55)
341GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps
342GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M)
343Clamp FOR Top Channel with Nut bolt
344G.I. Barbed Wire
34511 KV Pin Insulator Polymer Type as per TS
34611 KV Polymer Disc Insulators45 KNT&C Type
34711 KV Disc Fitting T & C type
348PG Clamp for Rabbit
349E- Bracket for 11 KV line
35011 KV Danger Board with Clamp and Nuts & Bolts
351Aluminium paint
352Red Oxide Paint
353Earthing Coil connected with nutbolt using Charchol and Salt
354Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
355HT Guy Insulator
356GI Stay Wire 7/10 SWG
357HT Stay Clamp as per approved drawing-11 KV
358Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing
359Cable laying by Horizontal Directional Drilling Method
360Statutory Clearances including documentation,approval fee and all other charges (for National Highway)
361Statutory Clearances including documentation,approval fee and all other charges (for State Highway)
362Erection, Testingand commissioning of 11 KV Railway Crossing (Complete Work in all respect)
36311 kVXLPE Cable 3x185 Sq. mm. (Armoured)
364Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable
365HDPE Pipe, PN-4 PE-80(160 mm dia.) with clamp, etc
366GI Pipe 6" Diameter with clamps
36711 Meter long STP as per Approved Drawing and Technical specification (SP-55)
368GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps
369GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M)
370Clamp FOR Top Channel with Nut bolt
371G.I. Barbed Wire
37211 KV Pin Insulator Polymer Type as per TS
37311 KV Polymer Disc Insulators45 KNT&C Type
37411 KV Disc Fitting T & C type
375PG Clamp for Rabbit
376E- Bracket for 11 KV line
37711 KV Danger Board with Clamp and Nuts & Bolts
378Aluminium paint
379Red Oxide Paint
380Earthing Coil connected with nutbolt using Charchol and Salt
3819 KV LA , 10 KA (Station Class)
382Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
383HT Guy Insulator
384GI Stay Wire 7/10 SWG
385HT Stay Clamp as per approved drawing-11 KV
386Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing
387Cable laying by Horizontal Directional Drilling Method
388Statutory Clearances including documentation,approval fee,way leave charges and all other charges (For Railway Crossing)
389Erection, Testingand commissioning of 11 kV Line crossing by 33KV Existing Lines on STP 13 Mtr with Cradle Guarding (Complete Work in all respect)
39013 Meter long STP as per Approved Drawing and Technical specification (SP-72)
39133 KV Steel X-arm V type (GI Channel 100 X 50 X 6 mm )
39233 KV Cross arm holding clamps with bolts & nuts
39333 KV Composit Pin Insulator (Polymer Type)
394GI. guarding Angle 75x75x6 mm 3010 mm long with Clamp
395F- Bracket for 33 KV line
396Turn buckle
397G.I. Wire 6 SWG
398G.I. Wire 8 SWG
399G.I. Wire No. 16 SWG for binding
400Eye Bolt
401Helical formed Fitting
40211 KV Danger Board with Clamp and Nuts & Bolts
40311 KV Number Plate with Clamp and Nuts & Bolts
404G.I. Barbed Wire
405Red Oxide Paint
406Aluminium paint
407Aluminium binding wire - 6 SWG
408Earthing Coil connected with nutbolt using Charchol and Salt
409Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc.
41033 KV Stay Complete (GI Stay Rod 20x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers
411HT Guy Insulator
412GI Stay Wire 7/8 SWG
413HT Stay Clamp as per approved drawing-33 KV
414Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.64 Cmt (13 Meter - STP ) as per approved Drawing
415Erection, Testingand commissioning of LT Line crossing by 11 kV Lines on STP 11 Mtr with Cradle Guarding (Complete Work in all respect)
41611 Meter long STP as per Approved Drawing and Technical specification (SP-55)
41711 KV Steel X-arm V type (GI Channel 65X 65 X 6 mm )
41811 KV Cross arm holding clamps with bolts & nuts
41911 KV Pin Insulator Polymer Type as per TS
420F- Bracket for 11 KV line
421Guarding angle 65x55x6 mm, 1.6 mtr. With Clamp
422Turn buckle
423G.I. Wire 6 SWG
424G.I. Wire 8 SWG
425G.I. Wire No. 16 SWG for binding
426Eye Bolt
427Helical formed Fitting
42811 KV Danger Board with Clamp and Nuts & Bolts
42911 KV Number Plate with Clamp and Nuts & Bolts
430G.I. Barbed Wire
431Red Oxide Paint
432Aluminium paint
433Aluminium binding wire - 6 SWG
434Earthing Coil connected with nutbolt using Charchol and Salt
435Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc.
436Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
437HT Guy Insulator
438GI Stay Wire 7/8 SWG
439HT Stay Clamp as per approved drawing-11 KV
440Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing
441Erection, Testingand commissioning of UG Cable 11 KV Line (Complete Work in all respect)
442Radar route survey for route profile of any utility cables,pipes etc. along the route as per TS and scope of work
44311 kVXLPE Cable 3x185 Sq. mm. (Armoured)
444Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable
445Cable jointing kit straight through (3x185)
446GI Pipe 6" Diameter with clamps
447Cable Route Marker
448HDPE Pipe, PN-4 PE-80(160 mm dia.) with clamp, etc
44911 Meter long STP as per Approved Drawing and Technical specification (SP-55)
450GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps
451GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M)
452Clamp FOR Top Channel with Nut bolt
453G.I. Barbed Wire
45411 KV Pin Insulator Polymer Type as per TS
45511 KV Polymer Disc Insulators45 KNT&C Type
45611 KV Disc Fitting T & C type
457PG Clamp for Rabbit
458E- Bracket for 11 KV line
45911 KV Danger Board with Clamp and Nuts & Bolts
460Aluminium paint
461Red Oxide Paint
462Earthing Coil connected with nutbolt using Charchol and Salt
463Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
464HT Guy Insulator
465GI Stay Wire 7/10 SWG
466HT Stay Clamp as per approved drawing-11 KV
467Road Restoration Chages forRoad Crossing
468Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing
469Erection, Testingand commissioningof 11/0.433 KV three phase Transformer sub-station -25 KVA ,63 KVA and 100 KVA (Complete Work in all respect)
47025 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type)
47163 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type)
472100 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type)
4738.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
474Stone Pad (300x300x75mm)
475GI Top channel 125x65x6 mm., 2240 mmlong
476GI Channel 100x50x6 mm 2028 mm long (For Fuse Set )
477GIangle 75x75x6x2028 mm with clamp &bolt and nut (T/F base)
478Holding clamps for Top channel, GI Channel & GI Angle with bolts & nuts
479Tee-off Channel 100x50x1300 mm with clamp, Nut & Bolt
480Clamps for LT T-off with bolts & nuts
48111 KV Polymer Disc Insulators45 KNT&C Type
48211 KV Disc Fitting T & C type
48311 KV Pin Insulator Polymer Type as per TS
48411KV TPMO with fixing clamps
48511KV Fuse Set (Drop out) with clamps
4869 KV LA , 5 KA (Distribution Class)
487LT Distribution Box withMCCB and AMI metering (Smart Meter compitable with System) equipment & fixing arrangement As per TS . (SMC Type) for 25KVA (DRG- no. REC/RDSS/DTR/SS/24)
488LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/16) equipment & fixing arrangement As per TS . (SMC Type) for 63 KVA (DRG- no. REC/RDSS/DTR/SS/23)
489LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/23) equipment & fixing arrangement As per TS . (SMC Type) for 100KVA (DRG- no. REC/RDSS/DTR/SS/23)
490LT XLPE cable 4x16 Sq mm
491LT XLPE cable 3.5x70 Sq mm
492LT XLPE cable 3.5x150 Sq mm
49311 KV Danger Board with Clamp and Nuts & Bolts
494G.I. Barbed Wire
495ACSR Rabbit Conductor -Jumpering Works
496Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
497HT Guy Insulator
498GI Stay Wire 7/10 SWG
499HT Stay Clamp as per approved drawing-11 KV
500Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc.
501GI Flat 25X3 for Earthing
502Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing
503Shifting , Erection, Testingand commissioningof Existing Distribution Transformer-25 KVA ,63 KVA and 100 KVA (Complete Work in all respect)
504Dismentaling of 25 KVA Distribution Transformer along with accessories. Relocate the DT only at new location , Testing ,commissioning and charging and other material shifting to store.
505Dismentaling of 63 KVA Distribution Transformer along with accessories. Relocate the DT only at new location , Testing ,commissioning and charging and other material shifting to store.
506Dismentaling of 100 KVA Distribution Transformer along with accessories. Relocate the DT only at new location , Testing ,commissioning and charging and other material shifting to store.
5078.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
508Stone Pad (300x300x75mm)
509GI Top channel 125x65x6 mm., 2240 mmlong
510GI Channel 100x50x6 mm 2028 mm long (For Fuse Set )
511GIangle 75x75x6x2028 mm with clamp &bolt and nut (T/F base)
512Holding clamps for Top channel, GI Channel & GI Angle with bolts & nuts
513Tee-off Channel 100x50x1300 mm with clamp, Nut & Bolt
514Clamps for LT T-off with bolts & nuts
51511 KV Polymer Disc Insulators45 KNT&C Type
51611 KV Disc Fitting T & C type
51711 KV Pin Insulator Polymer Type as per TS
51811KV TPMO with fixing clamps
51911KV Fuse Set (Drop out) with clamps
5209 KV LA , 5 KA (Distribution Class)
521LT Distribution Box withMCCB and AMI metering (Smart Meter compitable with System) equipment & fixing arrangement As per TS . (SMC Type) for 25KVA (DRG- no. REC/RDSS/DTR/SS/24)
522LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/16) equipment & fixing arrangement As per TS . (SMC Type) for 63 KVA (DRG- no. REC/RDSS/DTR/SS/23)
523LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/23) equipment & fixing arrangement As per TS . (SMC Type) for 100KVA (DRG- no. REC/RDSS/DTR/SS/23)
524LT XLPE cable 4x16 Sq mm
525LT XLPE cable 3.5x70 Sq mm
526LT XLPE cable 3.5x150 Sq mm
52711 KV Danger Board with Clamp and Nuts & Bolts
528G.I. Barbed Wire
529ACSR Rabbit Conductor -Jumpering Works
530Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
531HT Guy Insulator
532GI Stay Wire 7/10 SWG
533HT Stay Clamp as per approved drawing-11 KV
534Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc.
535GI Flat 25X3 for Earthing
536Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing
537Erection, Testingand commissioningof 11/0.250 KV Single phase Transformer sub-station -10 KVA and 16 KVA (Complete Work in all respect)
53810 KVA, 11KV/250 V, 1 Ph Transformer (Level-1 Self Protected Aluminium Wound Type)
53916 KVA, 11KV/250 V, 1 Ph Transformer (Level-1 Self Protected Aluminium Wound Type)
540LT Distribution Box withMCCB for protection of 10 KVA T/F and Bus Bar foroutgoing consumer connections with Energy Meter (SMC Type) as per TS. (DRG- no.REC/RDSS/DTR/SS/20 )
541LT Distribution Box withMCCB for protection of 16 KVA T/F and Bus Bar foroutgoing consumer connections with Energy Meter (SMC Type) as per TS.( DRG- no. REC/RDSS/DTR/SS/20 )
542Clamps for Dist. Box (40x6 mm)
543Clamps for T/F (75x8 mm GI flat).
544ACSR Weasel Conductor-Jumpering Works
54511 KV Pin Insulator Polymer Type as per TS
546Eye Bolt
547L.T. XLPE cable 10 Sq. mm Single Core
548Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc.
549Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
550HT Guy Insulator
551GI Stay Wire 7/10 SWG
552HT Stay Clamp as per approved drawing-11 KV
553Shifting , Erection, Testingand commissioningof Existing Distribution Transformer-10 KVAand 16 KVA(Complete Work in all respect)
554Dismentaling of 10 KVA Distribution Transformer along with accessories. Relocate the DT only at new location , Testing ,comissioning and charging and other material shifting to store.
555Dismentaling of 16 KVA Distribution Transformer along with accessories. Relocate the DT only at new location , Testing ,comissioning and charging and other material shifting to store.
556LT Distribution Box withMCCB for protection of 10 KVA T/F and Bus Bar foroutgoing consumer connections with Energy Meter (SMC Type) as per TS. (DRG- no.REC/RDSS/DTR/SS/20 )
557LT Distribution Box withMCCB for protection of 16 KVA T/F and Bus Bar foroutgoing consumer connections with Energy Meter (SMC Type) as per TS.( DRG- no. REC/RDSS/DTR/SS/20 )
558Clamps for Dist. Box (40x6 mm)
559Clamps for T/F (75x8 mm GI flat).
560ACSR Weasel Conductor-Jumpering Works
56111 KV Pin Insulator Polymer Type as per TS
562Eye Bolt
563L.T. XLPE cable 10 Sq. mm Single Core
564Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc.
565Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
566HT Guy Insulator
567GI Stay Wire 7/10 SWG
568HT Stay Clamp as per approved drawing-11 KV
569Shifting , Erection, Testingand commissioningof Existing Distribution Transformer-250 KVA(Complete Work in all respect)
570Dismentaling of Distribution Transformer along with accessories. Relocate the DT only at new location , Testing ,comissioning and charging and other material shifting to store.
57111 Meter long STP as per Approved Drawing and Technical specification (SP-55)
572GI Channel 100x50x6 mm 2028 mm long (For Fuse Set )
573Holding clamps for Top channel, GI Channel & GI Angle with bolts & nuts
574GI Top channel 125x65x6 mm., 2240 mmlong
575GIangle 75x75x6x2028 mm with clamp &bolt and nut (T/F base)
576GI Channel 75x75x6 mm &bolt and nut (T/F base Support)
57711 KV Polymer Disc Insulators45 KNT&C Type
57811 KV Disc Fitting T & C type
579Tee-off Channel 100x50x1300 mm with clamp, Nut & Bolt
580Clamps for LT T-off with bolts & nuts
58111 KV Pin Insulator Polymer Type as per TS
58211KV TPMO with fixing clamps
58311KV Fuse Set (Drop out) with clamps
584LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/23) equipment & fixing arrangement as per TS. (SMC Type) for 250KVA (DRG- no. REC/RDSS/DTR/SS/22)
585Copper L-Piece 50x225x10mm
586Copper L-Piece 50x225x12mm
587LT XLPE cable 3.5x400 Sq mm
588Al Lug long barrel off size
58911 KV Danger Board with Clamp and Nuts & Bolts
590G.I. Barbed Wire
591Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
592HT Guy Insulator
593GI Stay Wire 7/10 SWG
594HT Stay Clamp as per approved drawing-11 KV
595Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc.
596GI Flat 50X6 for Earthing
597GI Channel 125x65 mm
5989 KV LA , 5 KA (Distribution Class)
599Crimping type heavy duty aluminium lugs suitable for connection XLPE cables
600PG Clamp for Rabbit
601Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing
602DT"s Plinth Foundation
603Erection, Testingand commissioning of New LT Line With AB Cable(Complete Work in all respect)
6048.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
605Stone Pad (300x300x75mm)
606Aerial Bunched XLPE Cable 1X16 (Ph) + 1X25 ( Bare messenger cum neutral) sqmm
607Aerial Bunched XLPE Cable 3X50 (Ph) + 1X35 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm
608Aerial Bunched XLPE Cable 3X95 (Ph) + 1X70 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm
609Pole Clamps with with I-Hook & nut & bolts for laying ABC
610Dead End clamp (Insulated)
611Suspension clamps (Insulated)
612End Cap for AB cable
613PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral)
614Insulating Piercing Connector (16-150 sq.mm)
6151x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes.
616Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with clamps (40x3 mm) and nut & bolts
617Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with clamps (40x3 mm) and nut & bolts
618Earthing Coil connected with nutbolt using Charchol and Salt
619Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
620LT Guy Insulator
621GI Stay Wire 7/10 SWG
622LT Stay Clamp as per approved drawing
623Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing
624Erection, Testingand commissioning of 11KV Line Guarding (Complete Work in all respect)
625Guarding angle 65x55x6 mm, 1.6 mtr. With Clamp
626Height raising channel 100x50,2240 mm long
627Back clamp for Height raising channel holding clamps with bolts & nuts
628G.I. Wire 6 SWG
629G.I. Wire 8 SWG
630Turn Buckle
631Eye Bolt
632G.I. Wire No. 16 SWG for binding
633Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc.
634Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
635HT Guy Insulator
636GI Stay Wire 7/10 SWG
637HT Stay Clamp as per approved drawing-11 KV
638Erection, Testingand commissioning of Tee Of Channel (Complete Work in all respect)
639Tee-off Channel 100x50x1300 mm with clamp, Nut & Bolt
640GI Channel clamp with nuts & bolts
64111 KV Polymer Disc Insulators45 KNT&C Type
64211 KV Disc Fitting T & C type
64311 KV Pin Insulator Polymer Type as per TS
644PG Clamp for Rabbit
645Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09
646HT Guy Insulator
647GI Stay Wire 7/10 SWG
648HT Stay Clamp as per approved drawing-11 KV
649Installation of Sign Board with as per TS and Approved Drawing
650Sign Board as per TS and Approved Drawing
651Control Room Building Extention work (Complete Work in all respect)
652RCC Work of Building with Internal wiring works for Extension of Control room Building (36 Sqmtr) (Complete Works in all respect) as per approved drawing and specification
653Water pump, Toilet works as per approved drawing and specification