Dakshinanchal Vidyut Vitran Nigam Limited-DVVNL has published Development Of Distribution Infrastructure Kanpur Zone Development Of . Submission Date for this Tender is 30-08-2022. Infrastructure Work Tenders in kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 05-Aug-2022 | Corrigendum_1 | Technical Bid | 21-08-2022 |
2 | 18-Aug-2022 | Corrigendum_2_Revised_Form-21 | Technical Bid | 21-08-2022 |
3 | 18-Aug-2022 | Corrigendum_2 | Technical Bid | 21-08-2022 |
4 | 20-Aug-2022 | Date Extension-VII | Date | 30-08-2022 |
Sl. No. | Item Description |
1 | SUPPLY OF ITEMS |
2 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
3 | 9 Meter long STP as per Approved Drawing and Technical specification (SP-33) |
4 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
5 | 13 Meter long STP as per Approved Drawing and Technical specification (SP-72) |
6 | Stone Pad (300x300x75mm) |
7 | 1 core (Al.) 120mm2 LT Armoured XLPE Cable |
8 | 1 core (Al.) 95mm2 LT Armoured XLPE Cable |
9 | 1 core (Al.) 50mm2 LT Armoured XLPE Cable |
10 | 1 core (Al.) 25mm2 LT Armoured XLPE Cable |
11 | 11 kVXLPE Cable 3x185 Sq. mm. (Armoured) |
12 | 1x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes. |
13 | 1x25 mm2 Armoured XLPE insulated Al. LT Cable for energising the distribution boxes. |
14 | Armoured Service Cable 2CX4 SQMM For Single phase consumer for upto 2KW |
15 | Armoured Service Cable 2CX6 SQMM For Single phase consumer for above 2 and upto 4 KW |
16 | Armoured Service Cable 4CX10 SQMM For Three phase consumer for upto 10kW |
17 | Armoured Service Cable 4CX16 SQMM For Three phase consumer for upto 25kW |
18 | Aerial Bunched XLPE Cable 3X120 (Ph) + 1X95 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
19 | Aerial Bunched XLPE Cable 3X50 (Ph) + 1X35 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
20 | Aerial Bunched XLPE Cable 3X95 (Ph) + 1X70 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
21 | Aerial Bunched XLPE Cable 1X16 (Ph) + 1X25 ( Bare messenger cum neutral) sqmm |
22 | LT XLPE cable 3.5x150 Sq mm |
23 | LT XLPE cable 3.5x70 Sq mm |
24 | LT XLPE cable 4x16 Sq mm |
25 | L.T. XLPE cable 10 Sq. mm Single Core |
26 | LT XLPE cable 3.5x400 Sq mm |
27 | ACSR Rabbit Conductor |
28 | Aluminium binding wire - 6 SWG |
29 | Jointing sleave -ACSR Rabbit |
30 | Mid Span Joint 120mm2 |
31 | ACSR Rabbit Conductor -Jumpering Works |
32 | ACSR Weasel Conductor-Jumpering Works |
33 | 11 KV Danger Board with Clamp and Nuts & Bolts |
34 | 11 KV Number Plate with Clamp and Nuts & Bolts |
35 | 11KV Fuse Set (Drop out) with clamps |
36 | 11KV TPMO with fixing clamps |
37 | 10 KVA, 11KV/250 V, 1 Ph Transformer (Level-1 Self Protected Aluminium Wound Type) |
38 | 16 KVA, 11KV/250 V, 1 Ph Transformer (Level-1 Self Protected Aluminium Wound Type) |
39 | 25 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type) |
40 | 63 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type) |
41 | 100 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type) |
42 | LT Distribution Box withMCCB for protection of 10 KVA T/F and Bus Bar foroutgoing consumer connections with Energy Meter (SMC Type) as per TS. (DRG- no.REC/RDSS/DTR/SS/20 ) |
43 | LT Distribution Box withMCCB for protection of 16 KVA T/F and Bus Bar foroutgoing consumer connections with Energy Meter (SMC Type) as per TS.( DRG- no. REC/RDSS/DTR/SS/20 ) |
44 | LT Distribution Box withMCCB and AMI metering (Smart Meter compitable with System) equipment & fixing arrangement As per TS . (SMC Type) for 25KVA (DRG- no. REC/RDSS/DTR/SS/24) |
45 | LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/16) equipment & fixing arrangement As per TS . (SMC Type) for 63 KVA (DRG- no. REC/RDSS/DTR/SS/23) |
46 | LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/23) equipment & fixing arrangement As per TS . (SMC Type) for 100KVA (DRG- no. REC/RDSS/DTR/SS/23) |
47 | LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/23) equipment & fixing arrangement as per TS. (SMC Type) for 250KVA (DRG- no. REC/RDSS/DTR/SS/22) |
48 | Copper L-Piece 50x225x10mm |
49 | Copper L-Piece 50x225x12mm |
50 | Al Lug long barrel off size |
51 | 9 KV LA , 5 KA (Distribution Class) |
52 | 9 KV LA , 10 KA (Station Class) |
53 | Earthing Coil connected with nutbolt using Charchol and Salt |
54 | GI Flat 50X6 for Earthing |
55 | GI Flat 25X3 for Earthing |
56 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
57 | GI Pipe 6" Diameter with clamps |
58 | G.I. Barbed Wire |
59 | G.I. Wire No. 16 SWG for binding |
60 | G.I. Wire 6 SWG |
61 | G.I. Wire 8 SWG |
62 | 11 KV Disc Fitting T & C type |
63 | 11 KV Polymer Disc Insulators45 KNT&C Type |
64 | 11 KV Pin Insulator Polymer Type as per TS |
65 | 33 KV Composit Pin Insulator (Polymer Type) |
66 | LT Shackle Insulator |
67 | Insulating Piercing Connector (50-150 sq.mm) |
68 | Insulating Piercing Connector (16-150 sq.mm) |
69 | Dead End clamp (Insulated) |
70 | End Cap for AB cable |
71 | Suspension clamps (Insulated) |
72 | Pole Clamps with with I-Hook & nut & bolts for laying ABC |
73 | SS Strips As per Drg -REC/RDSS/LT-ACC-ABC/01 |
74 | Dead End assembly unit as Per Drg-REC/RDSS/LT-ACC-ABC/03 |
75 | Suspension assembly unit as Per Drg- REC/RDSS/LT-ACC-ABC/ |
76 | D-Straps |
77 | Insulation mastic tape (2inc X 10 feet). |
78 | Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with clamps (40x3 mm) and nut & bolts |
79 | Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with clamps (40x3 mm) and nut & bolts |
80 | Aluminium paint |
81 | Red Oxide Paint |
82 | Smart TVM Meter Compatible with System (AMI) complete Set |
83 | HDPE Pipe, PN-4 PE-80(160 mm dia.) with clamp, etc |
84 | Crimping type heavy duty aluminium lugs suitable for connection XLPE cables |
85 | Helical formed Fitting |
86 | Cable Route Marker |
87 | PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral) |
88 | PG Clamp for Rabbit |
89 | GI Stay Wire 7/10 SWG |
90 | GI Stay Wire 7/8 SWG |
91 | HT Guy Insulator |
92 | LT Guy Insulator |
93 | 33 KV Stay Complete (GI Stay Rod 20x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers |
94 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
95 | Turn Buckle |
96 | HT Stay Clamp as per approved drawing-33 KV |
97 | HT Stay Clamp as per approved drawing-11 KV |
98 | LT Stay Clamp as per approved drawing |
99 | 11 KV Cross arm holding clamps with bolts & nuts |
100 | 11 KV Steel X-arm V type (GI Channel 65X 65 X 6 mm ) |
101 | 33 KV Cross arm holding clamps with bolts & nuts |
102 | 33 KV Steel X-arm V type (GI Channel 100 X 50 X 6 mm ) |
103 | Angle for vertical ArmL50x50x6 (Type -A)-900MM |
104 | Angle for vertical ArmL50x50x6 (Type -B)- 900MM |
105 | Top Clamp for Vertical arm L 50X6 (Type -A)- 435 mm |
106 | Top Clamp for Vertical arm L 50X6 (Type -B)- 435 mm |
107 | Bottom Clamp for Vertical arm L 50X6 (Type -A)- 507 mm |
108 | Bottom Clamp for Vertical arm L 50X6 (Type -B)- 507 mm |
109 | Clamp FOR Top Channel with Nut bolt |
110 | Clamps for LT T-off with bolts & nuts |
111 | E- Bracket for 11 KV line |
112 | Eye Bolt |
113 | F- Bracket for 11 KV line |
114 | F- Bracket for 33 KV line |
115 | Guarding angle 65x55x6 mm, 1.6 mtr. With Clamp |
116 | Holding clamps for Top channel, GI Channel & GI Angle with bolts & nuts |
117 | GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M) |
118 | GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps |
119 | GI Channel 100x50x6 mm 2028 mm long (For Fuse Set ) |
120 | GI Top channel 125x65x6 mm., 2240 mmlong |
121 | Tee-off Channel 100x50x1300 mm with clamp, Nut & Bolt |
122 | Clamps for Dist. Box (40x6 mm) |
123 | Clamps for T/F (75x8 mm GI flat). |
124 | GI. guarding Angle 75x75x6 mm 3010 mm long with Clamp |
125 | Height raising channel 100x50,2240 mm long |
126 | Back clamp for Height raising channel holding clamps with bolts & nuts |
127 | GI Channel clamp with nuts & bolts |
128 | GI Channel 125x65 mm |
129 | GIangle 75x75x6x2028 mm with clamp &bolt and nut (T/F base) |
130 | GI Channel 75x75x6 mm &bolt and nut (T/F base Support) |
131 | 11 KV, 1250 A Outgoing VCB Indoor type with CTR 200/100/5 - 5A 350 MVA (Compatible with existing VCB at 33/11 KV substation) |
132 | Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable |
133 | Heat Shrinkable Jointing Kit indoor for 11 KV 3x185 sq. mm XLPE Cable |
134 | Cable jointing kit straight through (3x185) |
135 | Extra Prefabricated Items Like Clamp , Channel, Angle with Nut bolt |
136 | Satellite Multi-Tap Connector as per TS |
137 | Sign Board as per TS and Approved Drawing |
138 | ERECTION PART |
139 | Conversion of existing Service Cable to New Armoured Service cable with all required accessories like lugs etc. (Complete Work in all respect) and Removing and shifting of Existing Material to client store |
140 | Armoured Service Cable 2CX4 SQMM For Single phase consumer for upto 2KW |
141 | Armoured Service Cable 2CX6 SQMM For Single phase consumer for above 2 and upto 4 KW |
142 | Armoured Service Cable 4CX10 SQMM For Three phase consumer for upto 10kW |
143 | Armoured Service Cable 4CX16 SQMM For Three phase consumer for upto 25kW |
144 | Erection, Testingand commissioning of Replacement ofLT Bare Conductor with AB Cables (Complete Work in all respect) |
145 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
146 | 9 Meter long STP as per Approved Drawing and Technical specification (SP-33) |
147 | Stone Pad (300x300x75mm) |
148 | Aerial Bunched XLPE Cable 3X120 (Ph) + 1X95 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
149 | Aerial Bunched XLPE Cable 3X95 (Ph) + 1X70 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
150 | Aerial Bunched XLPE Cable 3X50 (Ph) + 1X35 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
151 | Pole Clamps with with I-Hook & nut & bolts for laying ABC |
152 | Dead End clamp (Insulated) |
153 | Suspension clamps (Insulated) |
154 | SS Strips As per Drg -REC/RDSS/LT-ACC-ABC/01 |
155 | Dead End assembly unit as Per Drg-REC/RDSS/LT-ACC-ABC/03 |
156 | Suspension assembly unit as Per Drg- REC/RDSS/LT-ACC-ABC/ |
157 | End Cap for AB cable |
158 | Insulating Piercing Connector (16-150 sq.mm) |
159 | PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral) |
160 | 1x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes. |
161 | Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with clamps (40x3 mm) and nut & bolts |
162 | Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with clamps (40x3 mm) and nut & bolts |
163 | Earthing Coil connected with nutbolt using Charchol and Salt |
164 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
165 | LT Guy Insulator |
166 | GI Stay Wire 7/10 SWG |
167 | LT Stay Clamp as per approved drawing |
168 | Removing and shifting of Existing Material to client store |
169 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
170 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.39 Cmt (9 Meter - STP ) as per approved Drawing |
171 | Erection, Testingand commissioning of Replacement ofAB Cable (Damage)with AB Cables (Complete Work in all respect) |
172 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
173 | 9 Meter long STP as per Approved Drawing and Technical specification (SP-33) |
174 | Stone Pad (300x300x75mm) |
175 | Aerial Bunched XLPE Cable 3X120 (Ph) + 1X95 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
176 | Aerial Bunched XLPE Cable 3X95 (Ph) + 1X70 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
177 | Pole Clamps with with I-Hook & nut & bolts for laying ABC |
178 | Dead End clamp (Insulated) |
179 | Suspension clamps (Insulated) |
180 | SS Strips As per Drg -REC/RDSS/LT-ACC-ABC/01 |
181 | Dead End assembly unit as Per Drg-REC/RDSS/LT-ACC-ABC/03 |
182 | Suspension assembly unit as Per Drg- REC/RDSS/LT-ACC-ABC/ |
183 | End Cap for AB cable |
184 | Insulating Piercing Connector (16-150 sq.mm) |
185 | PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral) |
186 | 1x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes. |
187 | Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with clamps (40x3 mm) and nut & bolts |
188 | Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with clamps (40x3 mm) and nut & bolts |
189 | Earthing Coil connected with nutbolt using Charchol and Salt |
190 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
191 | LT Guy Insulator |
192 | GI Stay Wire 7/10 SWG |
193 | LT Stay Clamp as per approved drawing |
194 | Removing and shifting of Existing Material to client store |
195 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
196 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.39 Cmt (9 Meter - STP ) as per approved Drawing |
197 | Erection, Testingand commissioning of Replacement of LT Line with XLPE Armoured Cables (Complete Work in all respect) |
198 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
199 | 9 Meter long STP as per Approved Drawing and Technical specification (SP-33) |
200 | Stone Pad (300x300x75mm) |
201 | Angle for vertical ArmL50x50x6 (Type -A)-900MM |
202 | Top Clamp for Vertical arm L 50X6 (Type -A)- 435 mm |
203 | Bottom Clamp for Vertical arm L 50X6 (Type -A)- 507 mm |
204 | Angle for vertical ArmL50x50x6 (Type -B)- 900MM |
205 | Top Clamp for Vertical arm L 50X6 (Type -B)- 435 mm |
206 | Bottom Clamp for Vertical arm L 50X6 (Type -B)- 507 mm |
207 | LT Shackle Insulator |
208 | D-Straps |
209 | 1 core (Al.) 120mm2 LT Armoured XLPE Cable |
210 | 1 core (Al.) 95mm2 LT Armoured XLPE Cable |
211 | 1 core (Al.) 50mm2 LT Armoured XLPE Cable |
212 | 1 core (Al.) 25mm2 LT Armoured XLPE Cable |
213 | Mid Span Joint 120mm2 |
214 | Insulating Piercing Connector (50-150 sq.mm) |
215 | Insulation mastic tape (2inc X 10 feet). |
216 | Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with clamps (40x3 mm) and nut & bolts |
217 | Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with clamps (40x3 mm) and nut & bolts |
218 | Satellite Multi-Tap Connector as per TS |
219 | 1x25 mm2 Armoured XLPE insulated Al. LT Cable for energising the distribution boxes. |
220 | Earthing Coil connected with nutbolt using Charchol and Salt |
221 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
222 | LT Guy Insulator |
223 | GI Stay Wire 7/10 SWG |
224 | LT Stay Clamp as per approved drawing |
225 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
226 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.39 Cmt (9 Meter - STP ) as per approved Drawing |
227 | Removing and shifting of Existing Material to client store |
228 | Survey , Erection, Testingand commissioning of 11 Kv Line (Feeder Spliting Due to over loading) on 8.5 Mtr PCC pole-916 CKM and 11 Mtr STP Pole -222 CKM (Complete Work in all respect) |
229 | Route survey and pole spotting for 11 KV line |
230 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
231 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
232 | ACSR Rabbit Conductor |
233 | Stone Pad (300x300x75mm) |
234 | 11 KV Steel X-arm V type (GI Channel 65X 65 X 6 mm ) |
235 | 11 KV Cross arm holding clamps with bolts & nuts |
236 | F- Bracket for 11 KV line |
237 | GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M) |
238 | Clamp FOR Top Channel with Nut bolt |
239 | GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps |
240 | E- Bracket for 11 KV line |
241 | 11 KV Pin Insulator Polymer Type as per TS |
242 | 11 KV Polymer Disc Insulators45 KNT&C Type |
243 | 11 KV Disc Fitting T & C type |
244 | PG Clamp for Rabbit |
245 | Aluminium binding wire - 6 SWG |
246 | Jointing sleave -ACSR Rabbit |
247 | 11 KV Danger Board with Clamp and Nuts & Bolts |
248 | G.I. Barbed Wire |
249 | Aluminium paint |
250 | Red Oxide Paint |
251 | Earthing Coil connected with nutbolt using Charchol and Salt |
252 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
253 | HT Guy Insulator |
254 | GI Stay Wire 7/10 SWG |
255 | HT Stay Clamp as per approved drawing-11 KV |
256 | 11 KV Number Plate with Clamp and Nuts & Bolts |
257 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
258 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing |
259 | Erection, Testingand commissioning of 11 KV VCB with complete Assoceries as apporoved Drawing and Tecchanical Specifiactions (Complete Work in all respect) |
260 | 11 KV, 1250 A Outgoing VCB Indoor type with CTR 200/100/5 - 5A 350 MVA (Compatible with existing VCB at 33/11 KV substation) |
261 | 11 kVXLPE Cable 3x185 Sq. mm. (Armoured) |
262 | Heat Shrinkable Jointing Kit indoor for 11 KV 3x185 sq. mm XLPE Cable |
263 | Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable |
264 | Smart TVM Meter Compatible with System (AMI) complete Set |
265 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
266 | GI Flat 50X6 for Earthing |
267 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
268 | Stone Pad (300x300x75mm) |
269 | GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M) |
270 | Clamp FOR Top Channel with Nut bolt |
271 | GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps |
272 | 11 KV Polymer Disc Insulators45 KNT&C Type |
273 | 11 KV Disc Fitting T & C type |
274 | PG Clamp for Rabbit |
275 | 11 KV Danger Board with Clamp and Nuts & Bolts |
276 | G.I. Barbed Wire |
277 | Earthing Coil connected with nutbolt using Charchol and Salt |
278 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
279 | HT Guy Insulator |
280 | GI Stay Wire 7/10 SWG |
281 | HT Stay Clamp as per approved drawing-11 KV |
282 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
283 | Survey , Erection, Testingand commissioning of 11 Kv Line (Feeder Sagrigation) (Complete Work in all respect) |
284 | Route survey and pole spotting for 11 KV line |
285 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
286 | ACSR Rabbit Conductor |
287 | Stone Pad (300x300x75mm) |
288 | 11 KV Steel X-arm V type (GI Channel 65X 65 X 6 mm ) |
289 | 11 KV Cross arm holding clamps with bolts & nuts |
290 | F- Bracket for 11 KV line |
291 | GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M) |
292 | Clamp FOR Top Channel with Nut bolt |
293 | GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps |
294 | E- Bracket for 11 KV line |
295 | 11 KV Pin Insulator Polymer Type as per TS |
296 | 11 KV Polymer Disc Insulators45 KNT&C Type |
297 | 11 KV Disc Fitting T & C type |
298 | PG Clamp for Rabbit |
299 | Aluminium binding wire - 6 SWG |
300 | Jointing sleave -ACSR Rabbit |
301 | 11 KV Danger Board with Clamp and Nuts & Bolts |
302 | G.I. Barbed Wire |
303 | Earthing Coil connected with nutbolt using Charchol and Salt |
304 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
305 | HT Guy Insulator |
306 | GI Stay Wire 7/10 SWG |
307 | HT Stay Clamp as per approved drawing-11 KV |
308 | 11 KV Number Plate with Clamp and Nuts & Bolts |
309 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
310 | Extra Prefabricated Items Like Clamp , Channel, Angle with Nut bolt |
311 | Erection, Testingand commissioning of 11 KV VCB with complete Assoceries as apporoved Drawing and Tecchanical Specifiactions(Feeder Segrigation) (Complete Work in all respect) |
312 | 11 KV, 1250 A Outgoing VCB Indoor type with CTR 200/100/5 - 5A 350 MVA (Compatible with existing VCB at 33/11 KV substation) |
313 | 11 kVXLPE Cable 3x185 Sq. mm. (Armoured) |
314 | Heat Shrinkable Jointing Kit indoor for 11 KV 3x185 sq. mm XLPE Cable |
315 | Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable |
316 | Smart TVM Meter Compatible with System (AMI) complete Set |
317 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
318 | GI Flat 50X6 for Earthing |
319 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
320 | Stone Pad (300x300x75mm) |
321 | GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M) |
322 | Clamp FOR Top Channel with Nut bolt |
323 | GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps |
324 | 11 KV Polymer Disc Insulators45 KNT&C Type |
325 | 11 KV Disc Fitting T & C type |
326 | PG Clamp for Rabbit |
327 | 11 KV Danger Board with Clamp and Nuts & Bolts |
328 | G.I. Barbed Wire |
329 | Earthing Coil connected with nutbolt using Charchol and Salt |
330 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
331 | HT Guy Insulator |
332 | GI Stay Wire 7/10 SWG |
333 | HT Stay Clamp as per approved drawing-11 KV |
334 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
335 | Erection, Testingand commissioning of 11 KV NH Crossing (Complete Work in all respect) |
336 | 11 kVXLPE Cable 3x185 Sq. mm. (Armoured) |
337 | Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable |
338 | HDPE Pipe, PN-4 PE-80(160 mm dia.) with clamp, etc |
339 | GI Pipe 6" Diameter with clamps |
340 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
341 | GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps |
342 | GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M) |
343 | Clamp FOR Top Channel with Nut bolt |
344 | G.I. Barbed Wire |
345 | 11 KV Pin Insulator Polymer Type as per TS |
346 | 11 KV Polymer Disc Insulators45 KNT&C Type |
347 | 11 KV Disc Fitting T & C type |
348 | PG Clamp for Rabbit |
349 | E- Bracket for 11 KV line |
350 | 11 KV Danger Board with Clamp and Nuts & Bolts |
351 | Aluminium paint |
352 | Red Oxide Paint |
353 | Earthing Coil connected with nutbolt using Charchol and Salt |
354 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
355 | HT Guy Insulator |
356 | GI Stay Wire 7/10 SWG |
357 | HT Stay Clamp as per approved drawing-11 KV |
358 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing |
359 | Cable laying by Horizontal Directional Drilling Method |
360 | Statutory Clearances including documentation,approval fee and all other charges (for National Highway) |
361 | Statutory Clearances including documentation,approval fee and all other charges (for State Highway) |
362 | Erection, Testingand commissioning of 11 KV Railway Crossing (Complete Work in all respect) |
363 | 11 kVXLPE Cable 3x185 Sq. mm. (Armoured) |
364 | Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable |
365 | HDPE Pipe, PN-4 PE-80(160 mm dia.) with clamp, etc |
366 | GI Pipe 6" Diameter with clamps |
367 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
368 | GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps |
369 | GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M) |
370 | Clamp FOR Top Channel with Nut bolt |
371 | G.I. Barbed Wire |
372 | 11 KV Pin Insulator Polymer Type as per TS |
373 | 11 KV Polymer Disc Insulators45 KNT&C Type |
374 | 11 KV Disc Fitting T & C type |
375 | PG Clamp for Rabbit |
376 | E- Bracket for 11 KV line |
377 | 11 KV Danger Board with Clamp and Nuts & Bolts |
378 | Aluminium paint |
379 | Red Oxide Paint |
380 | Earthing Coil connected with nutbolt using Charchol and Salt |
381 | 9 KV LA , 10 KA (Station Class) |
382 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
383 | HT Guy Insulator |
384 | GI Stay Wire 7/10 SWG |
385 | HT Stay Clamp as per approved drawing-11 KV |
386 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing |
387 | Cable laying by Horizontal Directional Drilling Method |
388 | Statutory Clearances including documentation,approval fee,way leave charges and all other charges (For Railway Crossing) |
389 | Erection, Testingand commissioning of 11 kV Line crossing by 33KV Existing Lines on STP 13 Mtr with Cradle Guarding (Complete Work in all respect) |
390 | 13 Meter long STP as per Approved Drawing and Technical specification (SP-72) |
391 | 33 KV Steel X-arm V type (GI Channel 100 X 50 X 6 mm ) |
392 | 33 KV Cross arm holding clamps with bolts & nuts |
393 | 33 KV Composit Pin Insulator (Polymer Type) |
394 | GI. guarding Angle 75x75x6 mm 3010 mm long with Clamp |
395 | F- Bracket for 33 KV line |
396 | Turn buckle |
397 | G.I. Wire 6 SWG |
398 | G.I. Wire 8 SWG |
399 | G.I. Wire No. 16 SWG for binding |
400 | Eye Bolt |
401 | Helical formed Fitting |
402 | 11 KV Danger Board with Clamp and Nuts & Bolts |
403 | 11 KV Number Plate with Clamp and Nuts & Bolts |
404 | G.I. Barbed Wire |
405 | Red Oxide Paint |
406 | Aluminium paint |
407 | Aluminium binding wire - 6 SWG |
408 | Earthing Coil connected with nutbolt using Charchol and Salt |
409 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
410 | 33 KV Stay Complete (GI Stay Rod 20x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers |
411 | HT Guy Insulator |
412 | GI Stay Wire 7/8 SWG |
413 | HT Stay Clamp as per approved drawing-33 KV |
414 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.64 Cmt (13 Meter - STP ) as per approved Drawing |
415 | Erection, Testingand commissioning of LT Line crossing by 11 kV Lines on STP 11 Mtr with Cradle Guarding (Complete Work in all respect) |
416 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
417 | 11 KV Steel X-arm V type (GI Channel 65X 65 X 6 mm ) |
418 | 11 KV Cross arm holding clamps with bolts & nuts |
419 | 11 KV Pin Insulator Polymer Type as per TS |
420 | F- Bracket for 11 KV line |
421 | Guarding angle 65x55x6 mm, 1.6 mtr. With Clamp |
422 | Turn buckle |
423 | G.I. Wire 6 SWG |
424 | G.I. Wire 8 SWG |
425 | G.I. Wire No. 16 SWG for binding |
426 | Eye Bolt |
427 | Helical formed Fitting |
428 | 11 KV Danger Board with Clamp and Nuts & Bolts |
429 | 11 KV Number Plate with Clamp and Nuts & Bolts |
430 | G.I. Barbed Wire |
431 | Red Oxide Paint |
432 | Aluminium paint |
433 | Aluminium binding wire - 6 SWG |
434 | Earthing Coil connected with nutbolt using Charchol and Salt |
435 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
436 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
437 | HT Guy Insulator |
438 | GI Stay Wire 7/8 SWG |
439 | HT Stay Clamp as per approved drawing-11 KV |
440 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing |
441 | Erection, Testingand commissioning of UG Cable 11 KV Line (Complete Work in all respect) |
442 | Radar route survey for route profile of any utility cables,pipes etc. along the route as per TS and scope of work |
443 | 11 kVXLPE Cable 3x185 Sq. mm. (Armoured) |
444 | Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable |
445 | Cable jointing kit straight through (3x185) |
446 | GI Pipe 6" Diameter with clamps |
447 | Cable Route Marker |
448 | HDPE Pipe, PN-4 PE-80(160 mm dia.) with clamp, etc |
449 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
450 | GI Angle Iron 65x65x6mm, 2700 mm long bracing with 4 clamps |
451 | GI Top channel 100x50x6 mm., 2240 mmlong (17.70 Kg/M) |
452 | Clamp FOR Top Channel with Nut bolt |
453 | G.I. Barbed Wire |
454 | 11 KV Pin Insulator Polymer Type as per TS |
455 | 11 KV Polymer Disc Insulators45 KNT&C Type |
456 | 11 KV Disc Fitting T & C type |
457 | PG Clamp for Rabbit |
458 | E- Bracket for 11 KV line |
459 | 11 KV Danger Board with Clamp and Nuts & Bolts |
460 | Aluminium paint |
461 | Red Oxide Paint |
462 | Earthing Coil connected with nutbolt using Charchol and Salt |
463 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
464 | HT Guy Insulator |
465 | GI Stay Wire 7/10 SWG |
466 | HT Stay Clamp as per approved drawing-11 KV |
467 | Road Restoration Chages forRoad Crossing |
468 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing |
469 | Erection, Testingand commissioningof 11/0.433 KV three phase Transformer sub-station -25 KVA ,63 KVA and 100 KVA (Complete Work in all respect) |
470 | 25 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type) |
471 | 63 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type) |
472 | 100 KVA , 11/0.433 KV T/F (Level-1 Self Protected Aluminium Wound Type) |
473 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
474 | Stone Pad (300x300x75mm) |
475 | GI Top channel 125x65x6 mm., 2240 mmlong |
476 | GI Channel 100x50x6 mm 2028 mm long (For Fuse Set ) |
477 | GIangle 75x75x6x2028 mm with clamp &bolt and nut (T/F base) |
478 | Holding clamps for Top channel, GI Channel & GI Angle with bolts & nuts |
479 | Tee-off Channel 100x50x1300 mm with clamp, Nut & Bolt |
480 | Clamps for LT T-off with bolts & nuts |
481 | 11 KV Polymer Disc Insulators45 KNT&C Type |
482 | 11 KV Disc Fitting T & C type |
483 | 11 KV Pin Insulator Polymer Type as per TS |
484 | 11KV TPMO with fixing clamps |
485 | 11KV Fuse Set (Drop out) with clamps |
486 | 9 KV LA , 5 KA (Distribution Class) |
487 | LT Distribution Box withMCCB and AMI metering (Smart Meter compitable with System) equipment & fixing arrangement As per TS . (SMC Type) for 25KVA (DRG- no. REC/RDSS/DTR/SS/24) |
488 | LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/16) equipment & fixing arrangement As per TS . (SMC Type) for 63 KVA (DRG- no. REC/RDSS/DTR/SS/23) |
489 | LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/23) equipment & fixing arrangement As per TS . (SMC Type) for 100KVA (DRG- no. REC/RDSS/DTR/SS/23) |
490 | LT XLPE cable 4x16 Sq mm |
491 | LT XLPE cable 3.5x70 Sq mm |
492 | LT XLPE cable 3.5x150 Sq mm |
493 | 11 KV Danger Board with Clamp and Nuts & Bolts |
494 | G.I. Barbed Wire |
495 | ACSR Rabbit Conductor -Jumpering Works |
496 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
497 | HT Guy Insulator |
498 | GI Stay Wire 7/10 SWG |
499 | HT Stay Clamp as per approved drawing-11 KV |
500 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
501 | GI Flat 25X3 for Earthing |
502 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
503 | Shifting , Erection, Testingand commissioningof Existing Distribution Transformer-25 KVA ,63 KVA and 100 KVA (Complete Work in all respect) |
504 | Dismentaling of 25 KVA Distribution Transformer along with accessories. Relocate the DT only at new location , Testing ,commissioning and charging and other material shifting to store. |
505 | Dismentaling of 63 KVA Distribution Transformer along with accessories. Relocate the DT only at new location , Testing ,commissioning and charging and other material shifting to store. |
506 | Dismentaling of 100 KVA Distribution Transformer along with accessories. Relocate the DT only at new location , Testing ,commissioning and charging and other material shifting to store. |
507 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
508 | Stone Pad (300x300x75mm) |
509 | GI Top channel 125x65x6 mm., 2240 mmlong |
510 | GI Channel 100x50x6 mm 2028 mm long (For Fuse Set ) |
511 | GIangle 75x75x6x2028 mm with clamp &bolt and nut (T/F base) |
512 | Holding clamps for Top channel, GI Channel & GI Angle with bolts & nuts |
513 | Tee-off Channel 100x50x1300 mm with clamp, Nut & Bolt |
514 | Clamps for LT T-off with bolts & nuts |
515 | 11 KV Polymer Disc Insulators45 KNT&C Type |
516 | 11 KV Disc Fitting T & C type |
517 | 11 KV Pin Insulator Polymer Type as per TS |
518 | 11KV TPMO with fixing clamps |
519 | 11KV Fuse Set (Drop out) with clamps |
520 | 9 KV LA , 5 KA (Distribution Class) |
521 | LT Distribution Box withMCCB and AMI metering (Smart Meter compitable with System) equipment & fixing arrangement As per TS . (SMC Type) for 25KVA (DRG- no. REC/RDSS/DTR/SS/24) |
522 | LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/16) equipment & fixing arrangement As per TS . (SMC Type) for 63 KVA (DRG- no. REC/RDSS/DTR/SS/23) |
523 | LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/23) equipment & fixing arrangement As per TS . (SMC Type) for 100KVA (DRG- no. REC/RDSS/DTR/SS/23) |
524 | LT XLPE cable 4x16 Sq mm |
525 | LT XLPE cable 3.5x70 Sq mm |
526 | LT XLPE cable 3.5x150 Sq mm |
527 | 11 KV Danger Board with Clamp and Nuts & Bolts |
528 | G.I. Barbed Wire |
529 | ACSR Rabbit Conductor -Jumpering Works |
530 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
531 | HT Guy Insulator |
532 | GI Stay Wire 7/10 SWG |
533 | HT Stay Clamp as per approved drawing-11 KV |
534 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
535 | GI Flat 25X3 for Earthing |
536 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
537 | Erection, Testingand commissioningof 11/0.250 KV Single phase Transformer sub-station -10 KVA and 16 KVA (Complete Work in all respect) |
538 | 10 KVA, 11KV/250 V, 1 Ph Transformer (Level-1 Self Protected Aluminium Wound Type) |
539 | 16 KVA, 11KV/250 V, 1 Ph Transformer (Level-1 Self Protected Aluminium Wound Type) |
540 | LT Distribution Box withMCCB for protection of 10 KVA T/F and Bus Bar foroutgoing consumer connections with Energy Meter (SMC Type) as per TS. (DRG- no.REC/RDSS/DTR/SS/20 ) |
541 | LT Distribution Box withMCCB for protection of 16 KVA T/F and Bus Bar foroutgoing consumer connections with Energy Meter (SMC Type) as per TS.( DRG- no. REC/RDSS/DTR/SS/20 ) |
542 | Clamps for Dist. Box (40x6 mm) |
543 | Clamps for T/F (75x8 mm GI flat). |
544 | ACSR Weasel Conductor-Jumpering Works |
545 | 11 KV Pin Insulator Polymer Type as per TS |
546 | Eye Bolt |
547 | L.T. XLPE cable 10 Sq. mm Single Core |
548 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
549 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
550 | HT Guy Insulator |
551 | GI Stay Wire 7/10 SWG |
552 | HT Stay Clamp as per approved drawing-11 KV |
553 | Shifting , Erection, Testingand commissioningof Existing Distribution Transformer-10 KVAand 16 KVA(Complete Work in all respect) |
554 | Dismentaling of 10 KVA Distribution Transformer along with accessories. Relocate the DT only at new location , Testing ,comissioning and charging and other material shifting to store. |
555 | Dismentaling of 16 KVA Distribution Transformer along with accessories. Relocate the DT only at new location , Testing ,comissioning and charging and other material shifting to store. |
556 | LT Distribution Box withMCCB for protection of 10 KVA T/F and Bus Bar foroutgoing consumer connections with Energy Meter (SMC Type) as per TS. (DRG- no.REC/RDSS/DTR/SS/20 ) |
557 | LT Distribution Box withMCCB for protection of 16 KVA T/F and Bus Bar foroutgoing consumer connections with Energy Meter (SMC Type) as per TS.( DRG- no. REC/RDSS/DTR/SS/20 ) |
558 | Clamps for Dist. Box (40x6 mm) |
559 | Clamps for T/F (75x8 mm GI flat). |
560 | ACSR Weasel Conductor-Jumpering Works |
561 | 11 KV Pin Insulator Polymer Type as per TS |
562 | Eye Bolt |
563 | L.T. XLPE cable 10 Sq. mm Single Core |
564 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
565 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
566 | HT Guy Insulator |
567 | GI Stay Wire 7/10 SWG |
568 | HT Stay Clamp as per approved drawing-11 KV |
569 | Shifting , Erection, Testingand commissioningof Existing Distribution Transformer-250 KVA(Complete Work in all respect) |
570 | Dismentaling of Distribution Transformer along with accessories. Relocate the DT only at new location , Testing ,comissioning and charging and other material shifting to store. |
571 | 11 Meter long STP as per Approved Drawing and Technical specification (SP-55) |
572 | GI Channel 100x50x6 mm 2028 mm long (For Fuse Set ) |
573 | Holding clamps for Top channel, GI Channel & GI Angle with bolts & nuts |
574 | GI Top channel 125x65x6 mm., 2240 mmlong |
575 | GIangle 75x75x6x2028 mm with clamp &bolt and nut (T/F base) |
576 | GI Channel 75x75x6 mm &bolt and nut (T/F base Support) |
577 | 11 KV Polymer Disc Insulators45 KNT&C Type |
578 | 11 KV Disc Fitting T & C type |
579 | Tee-off Channel 100x50x1300 mm with clamp, Nut & Bolt |
580 | Clamps for LT T-off with bolts & nuts |
581 | 11 KV Pin Insulator Polymer Type as per TS |
582 | 11KV TPMO with fixing clamps |
583 | 11KV Fuse Set (Drop out) with clamps |
584 | LT incoming Panel with AMI metering (Smart Meter compitable with System DRG- no. REC/RDSS/DTR/SS/23) equipment & fixing arrangement as per TS. (SMC Type) for 250KVA (DRG- no. REC/RDSS/DTR/SS/22) |
585 | Copper L-Piece 50x225x10mm |
586 | Copper L-Piece 50x225x12mm |
587 | LT XLPE cable 3.5x400 Sq mm |
588 | Al Lug long barrel off size |
589 | 11 KV Danger Board with Clamp and Nuts & Bolts |
590 | G.I. Barbed Wire |
591 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
592 | HT Guy Insulator |
593 | GI Stay Wire 7/10 SWG |
594 | HT Stay Clamp as per approved drawing-11 KV |
595 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
596 | GI Flat 50X6 for Earthing |
597 | GI Channel 125x65 mm |
598 | 9 KV LA , 5 KA (Distribution Class) |
599 | Crimping type heavy duty aluminium lugs suitable for connection XLPE cables |
600 | PG Clamp for Rabbit |
601 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.44 Cmt (11 Meter - STP ) as per approved Drawing |
602 | DT"s Plinth Foundation |
603 | Erection, Testingand commissioning of New LT Line With AB Cable(Complete Work in all respect) |
604 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification |
605 | Stone Pad (300x300x75mm) |
606 | Aerial Bunched XLPE Cable 1X16 (Ph) + 1X25 ( Bare messenger cum neutral) sqmm |
607 | Aerial Bunched XLPE Cable 3X50 (Ph) + 1X35 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
608 | Aerial Bunched XLPE Cable 3X95 (Ph) + 1X70 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm |
609 | Pole Clamps with with I-Hook & nut & bolts for laying ABC |
610 | Dead End clamp (Insulated) |
611 | Suspension clamps (Insulated) |
612 | End Cap for AB cable |
613 | PG Clamps 16 Sq mm .- 50 sq mm (For line to line jumpering of massenger wire & energizing DB Neutral) |
614 | Insulating Piercing Connector (16-150 sq.mm) |
615 | 1x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes. |
616 | Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with clamps (40x3 mm) and nut & bolts |
617 | Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with clamps (40x3 mm) and nut & bolts |
618 | Earthing Coil connected with nutbolt using Charchol and Salt |
619 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
620 | LT Guy Insulator |
621 | GI Stay Wire 7/10 SWG |
622 | LT Stay Clamp as per approved drawing |
623 | Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (1:2:4)-0.268 Cmt (8.5 Meter - PCC pole)as per approved Drawing |
624 | Erection, Testingand commissioning of 11KV Line Guarding (Complete Work in all respect) |
625 | Guarding angle 65x55x6 mm, 1.6 mtr. With Clamp |
626 | Height raising channel 100x50,2240 mm long |
627 | Back clamp for Height raising channel holding clamps with bolts & nuts |
628 | G.I. Wire 6 SWG |
629 | G.I. Wire 8 SWG |
630 | Turn Buckle |
631 | Eye Bolt |
632 | G.I. Wire No. 16 SWG for binding |
633 | Earthing Arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 SWG earthing wire etc. |
634 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
635 | HT Guy Insulator |
636 | GI Stay Wire 7/10 SWG |
637 | HT Stay Clamp as per approved drawing-11 KV |
638 | Erection, Testingand commissioning of Tee Of Channel (Complete Work in all respect) |
639 | Tee-off Channel 100x50x1300 mm with clamp, Nut & Bolt |
640 | GI Channel clamp with nuts & bolts |
641 | 11 KV Polymer Disc Insulators45 KNT&C Type |
642 | 11 KV Disc Fitting T & C type |
643 | 11 KV Pin Insulator Polymer Type as per TS |
644 | PG Clamp for Rabbit |
645 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers Ref- Drg - REC/RDSS/GEN/09 |
646 | HT Guy Insulator |
647 | GI Stay Wire 7/10 SWG |
648 | HT Stay Clamp as per approved drawing-11 KV |
649 | Installation of Sign Board with as per TS and Approved Drawing |
650 | Sign Board as per TS and Approved Drawing |
651 | Control Room Building Extention work (Complete Work in all respect) |
652 | RCC Work of Building with Internal wiring works for Extension of Control room Building (36 Sqmtr) (Complete Works in all respect) as per approved drawing and specification |
653 | Water pump, Toilet works as per approved drawing and specification |