Bids Are Invited For Visual Inspection As Per Item Descreption. , Rebound Hammer Testing As Per Item Descreption. Non Destructive Testing As Per Item Descreption. , Ultrasonic Pulse Velocity Test As Per Item Descreption. , Carbonation Test As Per I, delhi-Delhi

Indian Army-IA has published Bids Are Invited For Visual Inspection As Per Item Descreption. , Rebound Hammer Testing As Per Item Descreption. Non Destructive Testing As Per Item Descreption. , Ultrasonic Pulse Velocity Test As Per Item Descreption. , Carbonation Test As Per I. Submission Date for this Tender is 09-08-2022. Industrial Ultrasonic Testing Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

33335347
Bids Are Invited For Visual Inspection As Per Item Descreption. , Rebound Hammer Testing As Per Item Descreption. Non Destructive Testing As Per Item Descreption. , Ultrasonic Pulse Velocity Test As Per Item Descreption. , Carbonation Test As Per I
Open Tender
Indian
Delhi
delhi
09-08-2022

Tender Details

Bids Are Invited For Visual Inspection As Per Item Descreption. , Rebound Hammer Testing As Per Item Descreption. Non Destructive Testing As Per Item Descreption. , Ultrasonic Pulse Velocity Test As Per Item Descreption. , Carbonation Test As Per Item Descreption. , Core Test As Per Item Descreption. , Concrete Electrical Resistivity Test As Per Item Descreption. , Ph Value Test As Per Item Descreption. , Chemical Analysis As Per Item Descreption. , Slab Load Test As Per Item Descreption. , Structural Design And Drawings As Per Item Descreption. , Preparation Of Boq For Repair And Retrofitting With Material Specifications And Quantity Breakup. , Vetting Of Repair And Retrofitting Scheme From Any Govt Engg College

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Sl. No. Item TitleItem Description
1Visual inspectionas per item descreption.Structural assessment, Non destructive testing and repair and retrofitting designfor residential building No P-13 and P-15 Servant Quarters at RR Hospital.There are two Identical blocks G plus 3 RCC framed structure The consultant carry out the following inspection at the site and shall be submittedd the documents Visual inspection, for surface damages, delamination, spalling, local weaknesses, etc and their damage classification.Thevisualinspectionshallcoverall the residential units and all the structural components, Visualinspection would be documented inthe formof worksheets, photographic records, and distress over drawings, sketches etc All the observations shall be be tabulated duly giving reasons for observed damage and remedial measures for each type of distress and damage in conjection with NDT results
2Rebound Hammer Testing as per item descreption. NonDestructiveTesting as per item descreption.Rebound Hammer For determining the estimated compressive strength of concrete and uniformity of concrete in terms of surface hardness as per IS 13311 Part 2 1992. NonDestructiveTestingNon DestructiveEvaluationofthestructuralelementsby various tests at required locations and structural assessment based on these parameters
3UltrasonicPulseVelocityTest as per item descreption.UltrasonicPulseVelocityTestforascertainingthequalityofconcrete,soundnessand density of concrete, uniformity of concrete in terms of density as per IS 13311 Part 1 1992, ASTM C597 83, BS 6809 1981 and BS 1881 Part 203 and BS EN 13791.
4CarbonationTest as per item descreption.CarbonationTest Measurementofcarbonationdepthbyphenolphthaleinspraytestat selected location onRCC membersof thestructures coveredunder thestudy tosee the depth of carbonation as per BS EN 14630 2006, 13295 2004. Ratio of carbonation depth to cover depth is also measured to check the intensity of carbonation attack on steel bar.
5Core Test as per item descreption.Core Test Extracting the concrete core samples at select locations from RCC members of the structure covered under study and evaluating the properties fck value, grade of concrete inthelaboratoryfromthecoresamplesselectedasperIS456 2000, IS5161959,IS 1199 2002withoutencounteringanysteelreinforcementofRCCmembersatspecified locations with portable power driven core cutting equipment
6Concrete electrical resistivity test as per item descreption.Concrete electrical resistivity test Conducting electrical resistivity test for estimation of likelihood of corosion based on electrical resisitivity values.
7PHvaluetest as per item descreption.PHvaluetestTodrawsamplesofconcreteandpHValuetesttocheckalkanityof concrete as per relevant IS 456 2000, BS 8110.
8Chemical analysis as per item descreption.Chemical analysis To draw samples of concrete and carry out chemical analysis of the samples including measurement of Chloride Content
9Slab Load Test as per item descreption.Slab Load TestLoad carrying capacity analysis and deflection measurement of any kind of slab of building as perIS 4562000
10Structural design and drawings as per item descreption.Structural design and drawings of the various components required to be strengthened reconctructed in the buildings , along with methdology of execution of repairs and retrofitting works.
11Preparation of BOQ for repair and retrofitting with material specifications and quantity breakup.Preparation of BOQ for repair and retrofitting with material specifications and quantity breakup.
12Vettingofrepair and retrofitting schemefromany Govt Engg College.Vettingofrepair and retrofitting schemefromany Govt Engg College
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail