Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #33322343

Routine Day To Day Maintenance Of Miscellaneous Repair Of 07Xnos Hot Water Boiler And 04Xnos Water Supply Installations At Air Force Thoise

Issued by Statutory Bodies & Commissions/Committees · thoise, Jammu And Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Aug 2022
0 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
thoise → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Routine Day To Day Maintenance Of Miscellaneous Repair Of 07Xnos Hot Water Boiler And 04Xnos Water Supply Installations At Air Force Thoise

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 13-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-Aug-2022

BOQ

Name of Work : ROUTINE DAY TO DAY MAINTENANCE OF MISCELLANEOUS REPAIR OF 07XNOs HOT WATER BOILER AND 04XNOs WATER SUPPLY INSTALLATIONAT AIR FORCE STATION THOISE
Sl. No. Item Description
1Servicing of Hot Water Boiler , Disconnecting electric drain out water opening of burner chamber boiler asembly, all accessories and mountingtaking out helical coil of make-Alfa Therm hot generator 100000K Cal/Hrs, cleaning of combustion chamber repairing/replacement of any unserviceable parts as specified in each item complete all as specified and directed by Engr-in-Charge. Note :- The Job shall be carried out after every 2 Month of Boiler runandshall be measured and paid separatly, no of times carried out during entire period ofcontract
2Repair of hot water boiler of capacity 100000 K. cal/Hr including repair/replacement of following parts from Srl item No. 2.01 to 2.13to make it functional as specified and directed by Engr-in-Charge.
3Replacement of complete helical coil assembly.
4Replacement of input ignition transformer 220 Volts of outpot 11 KV to 14 KV.
5Replacement of gasket suitable for hot water boiler.
6Replacement of sequence controller for hot water boiler.
7Replacement of refactory plate as per sample.
8Replacement of differenial pressure Gauge - 0 to 10 Kg/Cm square suitable for hot water boiler.
9Replacement of Photo cell for hot water boiler.
10Supply and Fixing in replacement motorised barrel pump of capacity 1 HP, 2850 RPM , Single phase with rubber hose pipe 15 RM complete with all accessoriescomplete all as specified and directed by enger in charge.Make : Bharat, Kirloskar
11Replacement of un-serviceable gate valveof capacity 50 mm dia suitable for hot/cold waterMake Leader/Surya Parkash ISI marked
12Replacement of un-serviceable gate valve of capacity 40 mm dia suitable for hot/cold waterMake : Leader/Surya Parkash ISI marked.
13Replacement of solenoid valve for hot water boiler.
14Replacement of fuel TPL pipe to burning assembly for hot water boiler.
15Replaement of fuel filter assembly 1/2 Ltr capacity with filter.
16S&F in repair/ Replacment of Burner of Boiler for 1 L K cal make Ecoflame or Equivalent or as per sample complete all as specified and as directed by Engr-in-Charge.
17S&F in repair/ Replacment of Starting Panel ofBoiler for 1 L K cal makeas per sample Rapid Cool complete all as specified and as directed by Engr-in-Charge.
18S&F in repair/replacment of Electronic Buzzer for Hot Water Boiler of 1 L Kcal complete all as specified and as directed by Engr-in-Charge.
19S&F in repair/replacment of MNX 9 Contacter type for Hot Water Boiler of 1 L Kcal complete all as specified and as directed by Engr-in-Charge.
20S&F in repair/replacment of Bimetallic Relay of 3 to 5 Ampfor Hot Water Boiler of 1 L Kcal complete all as specified and as directed by Engr-in-Charge.
21S&F in repair/replacment of Single Phase Preventer for Hot Water Boiler of 1 L Kcal complete all as specified and as directed by Engr-in-Charge.
22S&F in repair/replacment of Control Module for Hot Water Boiler of 1 L Kcal complete all as specified and as directed by Engr-in-Charge.
23Supply and fixing in replacement, testing and commissioning ofcentrifugal pump set of capacity 3 HP, 3 Phase,2880 RPM, Head 22to 33m, size 50x40 mm, discharge 4.50 to 2.50 l/sas specified and directed by Engr-in-Charge.
24Supply and fixing in replacement, testing and commissioning of centrifugal pump set of capacity 5 HP, 3 Phase, 2880 RPM, Head 22to 33m, size 50x40 mm, discharge 4.50 to 2.50 L/sas specified and directed by Engr-in-Charge.
25Taking down old unserviceable cable and Supply and laying of PVC insulated sheathed 6 sqmm, 4 core flat multistrand copper conductor cable complete all as specfified and directed by Engr-in-Charge
26S&F in replacement complete Insulation wrapping for the tank in all boiler with 75 mm thick bounded mineral wool with wire mesh inclding provision of aluminium foil cover complete allas specified and directed by Engr-in-Charge.
27Rewinding ofPump motor of capcity 5 HP with super enamelled copper & wire of same gauge etc using best quality of insulation materials turning polishing of motor shaft by machining, replacement of bearing - 02 Nos including all necessary repair work to make the equipment functional complete all as specified and as directed by Engr-in-Charge.
28Rewinding of pump 3 HP with replacemnt of different unserviceable parts including all necessary repair work to make the equipment fully functional complete all as specified and as directed by Engr-in-Charge.Note :-Spare parts to be replaced for this item will be measured and paid separately.
29S&F in replacement of following Srl item No. 16.01 to 16.06 here-in-after as required for overhauling/repairing the submersible pump set under srl item No 10.00 and 11.00 here-in-before.
30Impeller
31Pump shaft
32Thrust Bearing
33Water seal
34NRV
35Bushing
36Emptying & cleannig of water tank of capacity 10,000 ltr PVC insulated sintex tank using cleaning solution and de-silting as specified and directed by Engr-in-Charge.
37S&F in replacement star delta starter suitablefor 5 HP submersible pump as specified and directed by Engr-in-Charge.
38S&F in replacement star delta starter suitablefor 20 HP submersible pump as specified and directed by Engr-in-Charge.
39S&F in replacement star delta starter suitablefor 3 HP submersible pump as specified and directed by Engr-in-Charge.
40M&LKFlex insulation forgalvanised water tubing and 19 mm thick including jointing& fixing material such as solvent adhesive , tape insulation self adhesive and polyshield coating, including polyglass tape and (Resion + Hardner) two coats as per manufacturer\"s recommendationincluding taking down following size listed at Srl No. 21.01 and 21.02 here-in-after complete all as specified and directed by Eng-in-Charge. Make : KFlex/ superion or equivalent as approved by GE.
4150 mm dia
4240 mm dia
43Taking up or down GI tubing and connections including cleaning & re-fixing and removal offollowing size listed at Srl Item No. 22.01 and 22.02 here-in-after complete all as specified and as directed by Engr-in-Charge :-
4450 mm dia
4540 mm dia
46S&F Steel water tube medium grade galvanised with all fittings including short lengths, laid in trenches/floors/wall with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) following size listed at Srl Item No. 23.01 and 23.02 complete as specified and as directed by Engr-in-Charge.MAKE:- JINDAL / SWASTIC/ TATA / PARKASH
4750 mm dia
4840 mm dia
49Supply, laying & Insulation of pipe line 75 mm thick bounded by mineral wool with wire mesh comletes inclding provision of aluminium foil covercomplete all as specified and directed by Engr-in-Charge.
50Taking down of existing MS Sheet hot water storage 1500 Ltrs tubular tank from the mounting and checking it for any leakages, damages etc and making on site arrangement for repair of tank by welding with suitable size MS plate making it completely leak proof and refixing the same after wraping with insulation at the existing height and dully fixing with fastner, nuts and bolts etc complete all as specified and directed by Engr-in-Charge.
51Supply and laying of PVC insulated sheathed multi starnded copper cunductor submercible pump 20 HP cable 10 sqmm, 4 core mulfistrand copper conductor cable complete all as specfified and directed by Engr-in-Charge
52Repair/Attending break down of Boilertto make completely functional in all respect to with out repalcing spare parts complete all as specified and as directed.Note:- The Item include any type of breakdown and sundry item cost deemed to be include in the quated rate.
53Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 63 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.Make: Schneider cat part No- LV426165 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemens.
54Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.Make: Schneider cat part No- LV426165 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemens.
55M&L for in repair / replacment Change over switch, rating 200 Amps, four poles, 415 Volts, AC, 50 Hz, off load, conforms to IS:13947 (Part-3); IEC:60947-2, side handle, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.Make: Havells cat part No- IHBFFE0200 or equivalent in Indo-Asian/ L&T/ Legrand/ Standard/ ABB/ Controls and switchgears/ Merlin Gerin/ Schneider/ Siemens.
56Note: The work under subject BoQ (Srl item No. 1.00 to 30.00 ) is meant for maint and repair of Boiler in AF Stn Thoise under GE(AF) Thoise. The work shall be executed on ground on required basis but being remote station and extreme weather condition contractor must stand by all the material and Engineer to rectify the breakdown of Boiler. Contractor shall deploy sufficient resources to keep smooth working ofBoiler in the AF station.In addition, any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notifying the complaint, recovery @ Rs 2000/- per day shall be recovered from contractor\"s payment for each breakdown so notified.

AI Tender Summary

OUR REF NO 33322343
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 20-08-2022
Authority
Authority Name Military Engineer Services
Work Description Routine Day To Day Maintenance Of Miscellaneous Repair Of 07Xnos Hot Water Boiler And 04Xnos Water Supply Installations At Air Force Thoise
Basic Detail
Tender No GEAF/T-20/2022-23
Bidding Type Tender
Location
City thoise
State Jammu And Kashmir
Key Dates
Publish Date 13 Aug 2022
Submission Date 20 Aug 2022
Open Date 23 Aug 2022
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 40000
Exemption Not Available
Document List
Tendernotice_1.pdf
67ce4aec-1f13-4561-8a3c-2ea3ef6d1711.html
AppxtotenderDoc20.pdf
BOQ_605732.xls
tenderdoc20.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 20, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 20, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 23, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

67ce4aec-1f13-4561-8a3c-2ea3ef6d1711.html

pdf

AppxtotenderDoc20.pdf

xls

BOQ_605732.xls

pdf

tenderdoc20.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders