Construction Of 15, 000 Gallon Capacity Rcc Ground Level Reservoir Including Providing And Installation Of Pump Motor Set Etc. Including Electrical Accessories Under Dws Sub-Division, Rupaichari During The Year 2022-23.
Tender Overview
Project Description
Construction Of 15, 000 Gallon Capacity Rcc Ground Level Reservoir Including Providing And Installation Of Pump Motor Set Etc. Including Electrical Accessories Under Dws Sub-Division, Rupaichari During The Year 2022-23.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.-All kinds of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil |
| 3 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:i) 1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level: i) 1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishingand reinforcement-i) 1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate 20 mm nominal size) |
| 8 | Centering shuttering including struttings, propping etc. and removal of form work for: |
| 9 | i) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering ply |
| 10 | ii) Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
| 11 | iii) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 12 | iv) Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 13 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. i) Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 14 | Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required. |
| 15 | Proving, fitting fixing of 5000 GPH capacity submersible pump having 76.00 mtr head and motor set suitable for 3 phase 415 voltage Star Delta starting make (DUKE/ KSB/ KALAMA or equivalent) including Installation of submersible pump with motor upto the depth of100 ft by 80 mm dia GI pipe ( conforming to IS : 1239 medium class ) with tailpiece as required welded with 10 mm thick GI flange in/c providing fitting fixing by necessary rubber washer, nuts & bolts, MS safety clamp etc. as per required size and making necessary electrical connection with main switch / starter with motor in/c commissioning & trial run as per direction of the Engineer-in-charge (G.I. pipe of medium class for column assembly will be supplied by the agency at his cost). |
| 16 | Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge. i.35 HP/26 KW Relay range within 20-32 +10% |
| 17 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc. complete as per specification and direction of the Engineer-incharge.i).100 Amps |
| 18 | Providing and fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. |
| 19 | Providing and fitting fixing of moving iron type, Range 0-100/0-200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. |
| 20 | Providing earthing with perforated 40 mm dia G.I. pipe (Medium class) ( 12 mm dia perforation ) , laying of 4 mm dia GI wire from earth electrode to panel, including excavating hole of 600 mm dia and refilling with Salt and Charcoal / coke in alternate layers of 300 mm , as per standard specification and direction of the Engineer-in-charge.i) for 3-phase connection with 4.00 mtr. Long G.I. pipe |
| 21 | Providing and fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inch x 9 feet ), nuts & bolts etc. for irrection of the same by 1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats & plastic paint as per specification and direction of the Engineer-in-charge. |
| 22 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.A) PN - 1.0 |
| 23 | i) 100 mm dia |
| 24 | ii) 150 mm dia |
| 25 | Providing and fixing C.I. non-return valveofapproved quality as per CPWD specification and direction of the Engineer- in - charge.i) 100 mm nominal bore |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender