Supply Of 11Kv Icog Spares Supply Of 11Kv Icog Spares , L&T Make Vacuum Circuit Breaker, Rated Current: 630A, Aux Contact: 6 No + 6 Nc Stc (Bil): 26.3Ka/3S (12Kv/28Kvrms/75Kvp) Tripping Coil: 110V Dc, Closing Coil: 110V Dc Spring Charging Motor: 230V Ac W, chembur-Maharashtra

Rashtriya Chemicals And Fertilizers Limited-RCF has published Supply Of 11Kv Icog Spares Supply Of 11Kv Icog Spares , L&T Make Vacuum Circuit Breaker, Rated Current: 630A, Aux Contact: 6 No + 6 Nc Stc (Bil): 26.3Ka/3S (12Kv/28Kvrms/75Kvp) Tripping Coil: 110V Dc, Closing Coil: 110V Dc Spring Charging Motor: 230V Ac W. Submission Date for this Tender is 08-08-2022. Absorbents Tenders in chembur Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

33305991
Supply Of 11Kv Icog Spares Supply Of 11Kv Icog Spares , L&T Make Vacuum Circuit Breaker, Rated Current: 630A, Aux Contact: 6 No + 6 Nc Stc (Bil): 26.3Ka/3S (12Kv/28Kvrms/75Kvp) Tripping Coil: 110V Dc, Closing Coil: 110V Dc Spring Charging Motor: 230V Ac W
Limitted
Indian
Maharashtra
chembur
08-08-2022

Tender Details

Supply Of 11Kv Icog Spares Supply Of 11Kv Icog Spares , L&T Make Vacuum Circuit Breaker, Rated Current: 630A, Aux Contact: 6 No + 6 Nc Stc (Bil): 26.3Ka/3S (12Kv/28Kvrms/75Kvp) Tripping Coil: 110V Dc, Closing Coil: 110V Dc Spring Charging Motor: 230V Ac Without Cc Superv.(Pin Type), Vcb With D/O Pt, Without Esw I/L Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56. , 2 Core Window Ct Cr-1: 630/1A, Burden: 10Va, Cl: 5P10, Rct(Max) At 75 Deg.= - Ohm, Cr-2: 630/1A, Burden: 10Va, Cl: 1.0, Isf: 10, Rct(Max) At 75 Deg.= - Ohm, Rct(Max) At 75 Deg.= - Ohm, Insulation: Min. E, Material: Cast Resin Bil: 12Kv/28Kv/75Kvp, Freq.: 50 Hz Std: Is 2705, Stc: 26.3Ka/3Sec Window Size: 34(W)X90(H), Secondary Term. On P1 Side Drawing No.: Pr-2371 (D), Model: Type-1 Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56. , Gun Type Pt Pri Volt: 11Kv/R3, Freq: 50 Hz Cr-1: Sec Volt: 110V/R3, Burden: 50 Va, Cl: 1/3P Cr-2: Sec Volt: 110V/3, Burden: 50 Va, Cl: 3P Insulation: Min. E, Mat: Cast Resin, Bil: 12 Kv/28 Kv/75 Kvp Std: Is- 3156, Ovf: 1.2 Cont. & 1.9 For 8 Hrs Drawing: E-4902-10/Rev-F, Model: E- 4902-10 With 3.15Acooper Bussman Fuse Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Abb Make Aux Relay, Model: Pq8nch2j Contacts: 5N/O+2N/C Control Voltage: 110V Dc Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Alstom Make Vaa33 Relay, Aux Supply: 110 - 125V Dc Case Size: 1/2Nh 20T, Contacts: 2 N/O H/R Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Alstom Make Vag11 (U/V) Relay Nominal Voltage: 110V Dc, Contacts: 1 N/O 1 N/C S/R,Case Size: 1/4N V 10T Setting:40% U/V, Flag: Reverse For U/V, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Rishab Make Moving Coil (Ac) Voltmeter Pt Ratio: 11Kv/R3:110V/R3, Accuracy Cl: Class 1 Pt Operated Size: 96 X 96, Range: 0-15 Kv Scale: 240 Degree Scale (Normal), Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56. , L&T Make Dpm Aux Supply: 80-300V Ac Display: Led (96 X 96), Meter Type: 1310 Ammmeter 3P Accuracy Cl: Class 1,Comm. Port: No Port Analog I/P: Nil, Analog O/P: Nil Digital I/P: Nil, Digital O/P: Nil, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T Make Dpm Aux Supply: 80-300V Ac Display: Led (96 X 96), Meter Type: 1320 Voltmeter 3P Accuracy Cl: Class 1,Comm. Port: No Port Analog I/P: Nil, Analog O/P: Nil Digital I/P: Nil, Digital O/P: Nil, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Rishab Make Analog Ammeter Type: Moving Coil (Ac),Size: 96 X 96 Current Input: Direct Reading, Accuracy Class: Class 1, Scale: 240 Degree Scale(Normal),Range: 0-6A Red Pointer: Required, Antiglare Glass: Required, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56. , L&T Make Dpm Aux Supply: 80-300V Ac/Dc Display: Led (96 X 96), Meter Type: 4400 Mfm Basic Accuracy Cl: Class 1,Comm. Port: Rs485 Port Analog I/P: Nil, Analog O/P: Nil Digital I/P: Nil, Digital O/P: Nil, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Rishab Make Analog Ammeter Type: Moving Coil (Ac),Size: 96 X 96 Current Input: Ct Operated,Ct Secondary: 1A Accuracy Class: Class 1, Scale: 240 Degree Scale(Normal),Range: 0-630A, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T-Salzer Make Vss (Std) (Off-Ry-Yb-Br), Door Mounting Size: 48*48, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T-Salzer Make Ass (Std) (Off-R-Y-B), Door Mounting Size: 48*48, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T-Salzer Make Trip-Neutral-Close Switch Rating: E:25 Amp, No. Of Contacts: 1:1No+1Nc(2Pole,3Pos), Sequence Locking: Q:Required,Latching Mechanism: S:Spring Return Mounting: B03:Standard Front Mounting, Ordering Code: 1Qsd00eb03pgbb, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56. , Salzer Make Off-On Selector Switch (240 Vac) 2P, 2Pos, 16A, Mounting: Base, Operate With Door Open Handle Type: Tear Drop, Size: 48*48 Nameplate Engraving:Off-On, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Salzer Make Off-On Selector Switch (110 Vdc) 2P, 2Pos, 16A, Mounting: Base, Operate With Door Open Handle Type: Flag Type, Size: 64*64 Nameplate Engraving:Off-On, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Siemens Make Aux Contactor- 3Th30, 4 No, 110V Dc,, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Omron Make Limit Switch For Vcb/Vcu Position Model: X-10Gm-B, Contact: 1 C/O, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Kaycee Make Limit Switch For Door Model: Kls001x-Oa, Contact: 1No+1Nc, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Kiyosh Make Resistor, Application: Pt Secondary(Damping Resistor), 50 Ohm, 200W, Model: Sri 200, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T Make Exora Series Four Pole - Fp Mcb Rating: 240/415V Ac, 6A, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T Make 6A Control Fuse With Fuse Base- Hc (Upto 63A), Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T Make 16A Control Fuse With Fuse Base- Hc (Upto 63A), Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T Make Neutral Link, 63A, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T (Esbee) Make Flush Head Non-Illuminated Push Button Colour: Black, Dia: 22.5 Mm Dia, Contacts: 1 Nc Legend: Remote Trip P.B Model: Emncfd1, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T-Esbee Make Gen X Cluster Led Type (Lvgp) Indication Lamp,Voltage: 110V Dc, Colour: Yellow, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T-Esbee Make Gen X Cluster Led Type (Lvgp) Indication Lamp,Voltage: 110V Dc, Colour: White, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T-Esbee Make Gen X Cluster Led Type (Lvgp) Indication Lamp,Voltage: 110V Dc, Colour: Red, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T-Esbee Make Gen X Cluster Led Type (Lvgp) Indication Lamp,Voltage: 110V Dc, Colour: Green, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T-Esbee Make Gen X Cluster Led Type (Lvgp) Indication Lamp, Voltage: 110V Dc, Colour: Blue, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , L&T-Esbee Make Gen X Cluster Led Type (Lvgp) Indication Lamp,Voltage: 110V Dc, Colour: Amber, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Anchor Make Batten Type Lamp Holder Rating: 240V Ac, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Vileco Make Panel Space Heater Rating: 240V, 150W, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Apt Make Thermostat, Range: 25-75 Deg Voltage : 230V Ac, 50Hz, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Connectwell Make Stud Type Polyamide Terminals For Main Supply Receiving, Model: Cstsn6u, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Elmex Make Stud Type Terminals For Ct Shorting Insulation Material: Polyamide,Model: Kltdm4, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Elmex Make Screw Type Polyamide Control Terminals Model: Kut2.5, Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Closing Coil Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 , Trip Coil Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453- 56 , Spring Charging Motor Suitable For 11Kv,630A L&T Vcb, Switchboard Drg. No. Myp3453-56 => Limited

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work:SUPPLY OF 11KV ICOG SPARES
Sl. No. Item Description
1L&T MAKE VACUUM CIRCUIT BREAKER, RATED CURRENT: 630A, AUX CONTACT: 6 NO + 6 NC STC (BIL): 26.3kA/3S (12kV/28kVrms/75kVp) TRIPPING COIL: 110V DC, CLOSING COIL: 110V DC SPRING CHARGING MOTOR: 230V AC WITHOUT CC SUPERV.(PIN TYPE), VCB WITH D/O PT, WITHOUT ESW I/L SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56.
22 CORE WINDOW CT CR-1: 630/1A, BURDEN: 10VA, CL: 5P10, Rct(max) AT 75 deg.= - OHM, CR-2: 630/1A, BURDEN: 10VA, CL: 1.0, ISF: 10, Rct(max) AT 75 deg.= - OHM, Rct(max) AT 75 deg.= - OHM, INSULATION: MIN. E, MATERIAL: CAST RESIN BIL: 12kV/28kV/75kVp, FREQ.: 50 Hz STD: IS 2705, STC: 26.3kA/3Sec WINDOW SIZE: 34(W)x90(H), SECONDARY TERM. ON P1 SIDE DRAWING NO.: PR-2371 (D), MODEL: TYPE-1 SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56.
3GUN TYPE PT PRI VOLT: 11KV/R3, FREQ: 50 Hz CR-1: SEC VOLT: 110V/R3, BURDEN: 50 VA, CL: 1/3P CR-2: SEC VOLT: 110V/3, BURDEN: 50 VA, CL: 3P INSULATION: MIN. E, MAT: CAST RESIN, BIL: 12 kV/28 kV/75 kVp STD: IS- 3156, OVF: 1.2 CONT. & 1.9 FOR 8 HRS DRAWING: E-4902-10/REV-F, MODEL: E- 4902-10 WITH 3.15ACOOPER BUSSMAN FUSE SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
4ABB MAKE AUX RELAY, MODEL: PQ8NCH2J CONTACTS: 5N/O+2N/C CONTROL VOLTAGE: 110V DC SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
5ALSTOM MAKE VAA33 RELAY, AUX SUPPLY: 110 - 125V DC CASE SIZE: 1/2NH 20T, CONTACTS: 2 N/O H/R SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
6ALSTOM MAKE VAG11 (U/V) RELAY NOMINAL VOLTAGE: 110V DC, CONTACTS: 1 N/O 1 N/C S/R,CASE SIZE: 1/4N V 10T SETTING:40% U/V, FLAG: REVERSE FOR U/V, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
7RISHAB MAKE MOVING COIL (AC) VOLTMETER PT RATIO: 11kV/R3:110V/R3, ACCURACY CL: CLASS 1 PT OPERATED SIZE: 96 X 96, RANGE: 0-15 KV SCALE: 240 DEGREE SCALE (NORMAL), SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56.
8L&T MAKE DPM AUX SUPPLY: 80-300V AC DISPLAY: LED (96 X 96), METER TYPE: 1310 AMMMETER 3P ACCURACY CL: CLASS 1,COMM. PORT: NO PORT ANALOG I/P: NIL, ANALOG O/P: NIL DIGITAL I/P: NIL, DIGITAL O/P: NIL, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
9L&T MAKE DPM AUX SUPPLY: 80-300V AC DISPLAY: LED (96 X 96), METER TYPE: 1320 VOLTMETER 3P ACCURACY CL: CLASS 1,COMM. PORT: NO PORT ANALOG I/P: NIL, ANALOG O/P: NIL DIGITAL I/P: NIL, DIGITAL O/P: NIL, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
10RISHAB MAKE ANALOG AMMETER TYPE: MOVING COIL (AC),SIZE: 96 X 96 CURRENT INPUT: DIRECT READING, ACCURACY CLASS: CLASS 1, SCALE: 240 DEGREE SCALE(NORMAL),RANGE: 0-6A RED POINTER: REQUIRED, ANTIGLARE GLASS: REQUIRED, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56.
11L&T MAKE DPM AUX SUPPLY: 80-300V AC/DC DISPLAY: LED (96 X 96), METER TYPE: 4400 MFM BASIC ACCURACY CL: CLASS 1,COMM. PORT: RS485 PORT ANALOG I/P: NIL, ANALOG O/P: NIL DIGITAL I/P: NIL, DIGITAL O/P: NIL, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
12RISHAB MAKE ANALOG AMMETER TYPE: MOVING COIL (AC),SIZE: 96 X 96 CURRENT INPUT: CT OPERATED,CT SECONDARY: 1A ACCURACY CLASS: CLASS 1, SCALE: 240 DEGREE SCALE(NORMAL),RANGE: 0-630A, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
13L&T-SALZER MAKE VSS (STD) (OFF-RY-YB-BR), DOOR MOUNTING SIZE: 48*48, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
14L&T-SALZER MAKE ASS (STD) (OFF-R-Y-B), DOOR MOUNTING SIZE: 48*48, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
15L&T-SALZER MAKE TRIP-NEUTRAL-CLOSE SWITCH RATING: E:25 AMP, NO. OF CONTACTS: 1:1NO+1NC(2POLE,3POS), SEQUENCE LOCKING: Q:REQUIRED,LATCHING MECHANISM: S:SPRING RETURN MOUNTING: B03:STANDARD FRONT MOUNTING, ORDERING CODE: 1QSD00EB03PGBB, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56.
16SALZER MAKE OFF-ON SELECTOR SWITCH (240 VAC) 2P, 2POS, 16A, MOUNTING: BASE, OPERATE WITH DOOR OPEN HANDLE TYPE: TEAR DROP, SIZE: 48*48 NAMEPLATE ENGRAVING:OFF-ON, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
17SALZER MAKE OFF-ON SELECTOR SWITCH (110 VDC) 2P, 2POS, 16A, MOUNTING: BASE, OPERATE WITH DOOR OPEN HANDLE TYPE: FLAG TYPE, SIZE: 64*64 NAMEPLATE ENGRAVING:OFF-ON, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
18SIEMENS MAKE AUX CONTACTOR- 3TH30, 4 NO, 110V DC,, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
19OMRON MAKE LIMIT SWITCH FOR VCB/VCU POSITION MODEL: X-10GM-B, CONTACT: 1 C/O, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
20KAYCEE MAKE LIMIT SWITCH FOR DOOR MODEL: KLS001X-OA, CONTACT: 1NO+1NC, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
21KIYOSH MAKE RESISTOR, APPLICATION: PT SECONDARY(DAMPING RESISTOR), 50 OHM, 200W, MODEL: SRI 200, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
22L&T MAKE EXORA SERIES FOUR POLE - FP MCB RATING: 240/415V AC, 6A, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
23L&T MAKE 6A CONTROL FUSE WITH FUSE BASE- HC (UPTO 63A), SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
24L&T MAKE 16A CONTROL FUSE WITH FUSE BASE- HC (UPTO 63A), SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
25L&T MAKE NEUTRAL LINK, 63A, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
26L&T (ESBEE) MAKE FLUSH HEAD NON-ILLUMINATED PUSH BUTTON COLOUR: BLACK, DIA: 22.5 MM DIA, CONTACTS: 1 NC LEGEND: REMOTE TRIP P.B MODEL: EMNCFD1, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
27L&T-ESBEE MAKE GEN X CLUSTER LED TYPE (LVGP) INDICATION LAMP,VOLTAGE: 110V DC, COLOUR: YELLOW, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
28L&T-ESBEE MAKE GEN X CLUSTER LED TYPE (LVGP) INDICATION LAMP,VOLTAGE: 110V DC, COLOUR: WHITE, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
29L&T-ESBEE MAKE GEN X CLUSTER LED TYPE (LVGP) INDICATION LAMP,VOLTAGE: 110V DC, COLOUR: RED, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
30L&T-ESBEE MAKE GEN X CLUSTER LED TYPE (LVGP) INDICATION LAMP,VOLTAGE: 110V DC, COLOUR: GREEN, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
31L&T-ESBEE MAKE GEN X CLUSTER LED TYPE (LVGP) INDICATION LAMP, VOLTAGE: 110V DC, COLOUR: BLUE, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
32L&T-ESBEE MAKE GEN X CLUSTER LED TYPE (LVGP) INDICATION LAMP,VOLTAGE: 110V DC, COLOUR: AMBER, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
33ANCHOR MAKE BATTEN TYPE LAMP HOLDER RATING: 240V AC, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
34VILECO MAKE PANEL SPACE HEATER RATING: 240V, 150W, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
35APT MAKE THERMOSTAT, RANGE: 25-75 DEG VOLTAGE : 230V AC, 50Hz, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
36CONNECTWELL MAKE STUD TYPE POLYAMIDE TERMINALS FOR MAIN SUPPLY RECEIVING, MODEL: CSTSN6U, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
37ELMEX MAKE STUD TYPE TERMINALS FOR CT SHORTING INSULATION MATERIAL: POLYAMIDE,MODEL: KLTDM4, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
38ELMEX MAKE SCREW TYPE POLYAMIDE CONTROL TERMINALS MODEL: KUT2.5, SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
39CLOSING COIL SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
40TRIP COIL SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453- 56
41SPRING CHARGING MOTOR SUITABLE FOR 11KV,630A L&T VCB, SWITCHBOARD DRG. NO. MYP3453-56
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail