Welcome Maint To Omqs Smqs Repair To External And Internal Plastering Guniting Works Etc And Certain Internal Em Work At Af Stn Rajokri And Periodical Services External Internal Plastering Repair To Flooring Tilling Joineries Brick Works Aluminium Wo , gurgaon-Haryana

Military Engineer Services-MES has published Welcome Maint To Omqs Smqs Repair To External And Internal Plastering Guniting Works Etc And Certain Internal Em Work At Af Stn Rajokri And Periodical Services External Internal Plastering Repair To Flooring Tilling Joineries Brick Works Aluminium Wo . Submission Date for this Tender is 27-08-2022. Civil Work Tenders in gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

33301644
Corrigendum : Welcome Maint To Omqs Smqs Repair To External And Internal Plastering Guniting Works Etc And Certain Internal Em Work At Af Stn Rajokri And Periodical Services External Internal Plastering Repair To Flooring Tilling Joineries Brick Works Aluminium Wo
Open Tender
Indian
Haryana
gurgaon
27-08-2022

Tender Details

Welcome Maint To Omqs Smqs Repair To External And Internal Plastering Guniting Works Etc And Certain Internal Em Work At Af Stn Rajokri And Periodical Services External Internal Plastering Repair To Flooring Tilling Joineries Brick Works Aluminium Wo

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-08-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 88000.0 /-
Tender Value
INR 44 Lakhs /-

BOQ Items

Name of Work : WELCOME MAINT TO OMQs SMQs REPAIR TO EXTERNAL AND INTERNAL PLASTERING GUNITING WORKS ETC AND CERTAIN INTERNAL EM WORK AT AF STN RAJOKRI AND PERIODICAL SERVICES EXTERNAL INTERNAL PLASTERING REPAIR TO FLOORING TILLING JOINERIES BRICK WORKS ALUMINIUM WORKS SANITARY FITTINGS CERTAIN B&R WORKS AND REPAIRS TO DG SETS TRANSFORMERS LT PANELS VCB RMU AND CERTAIN INTERNAL EM WORKS ETC AT DPDO GURGAON UNDER AGE EM AF RAJOKRI OF GE AF GURGAON
Sl. No. Item Description
1Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
2M&L for screed bed or bedding layer of mortar 15mm thick in cement mortar (1:6)for bedding of tilescomplete all as specified.
3M&L for 10 mm thick rendering in cement mortar (1:4) on vertical surfaces for backing of tiles complete all as specifed.
4M&L for joint free Non- skid ceramic coloured tiles 7 to 8mm thick (Square/ rectangular) area of each tile exceeding 0.11 but n.exc 0.18 Sqm, in floors/shirtingetc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
5M&L joint free Glazed ceramic coloured/ printed tiles in vertical surface of size 350x 250 x 6-7mm/450x 300 x 6-7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match on walls as in dado/ skirting etc complete all as specified.
6Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified.
7M&L for 25 mm thick PCC 1 :2 :4type B-0 (using 12.50 mm graded stone aggregate) as in floor complete all as specified.
8M&L for ColouredVitrifiedCeramic tiles 9-10 mm thick (Square/rectangular) oflight Shade , polished, area of each tilenot exceeding 0.36 sqm, fixed in floor/skirting etc overset and jointed in neatcement slurry and pointed in coloured cement to match with coloured tiles complete all as specified.
9Dismanting of stone slab and tiles laid bedded and pointed in any mortar of any size description or thickness in floor, appron etc.
10M&L for 18-20 mm thick Granite tiles machine cut , bedded and jointed with grey cements slurry and pointed with white or colour cement with admixture of pigment to match the shade of granite stone including grinding & polishing slab over screed bed or bedding layer of mortar 15 mm thick in cement mortar (1 : 4)laid complete all as specified.
11M & L for 18-20 mm thick Granite tiles machine cut, in skirting/dado laid over cement mortar and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 10 mm thick rendering in cement mortar (1:4) on vertical surfaces for backing of tiles complete all as specified.
12M&L for guniting work to RCC work in column, flooring, side walls, beam, slab, etc by removing loose concrete cover etc, cleaning of surface with wire brush and applying epoxy paint to rusted reinforcement and S&F welded wire mesh fabric or wire net less than 95 X 95X 3 mm adhesive, plaster grade for concrete admixture 1 part of cement and 3.5 part of sand and average thickness 40 mm and making the surface even including 15mm thick plastering in CM 1:4 on brick or concrete surfaces including finishing the surfaces even and smooth, without using extra cement plumb and making surface true to geometry in line and including necessary form work to be carried at upto Doublestorey building Note.- Where ever reinforcement required will be measured and paid seperatly etc complete all as specified.
13M&L for mild steel TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified.
14M&L for preparation of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing scrapping down smoke spot moulds moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two coat of oil bound distemper on walls complete all as specified.
15All as per item No.14 here-in-before but on surfaces of ceiling.
16M & L for providing 1-2mm thick wall care putty on wall before applying oil bound distemper and making the surface uniform all as specified.
17M&L for preparation of old painted surfaces of wood & wood based of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified.
18M&L for preparation of old painted surfaces of steelof any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified.
19Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys ,scrubbing down with water etc complete all as specified.
20M&L for 15mm thick plastering in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement) complete all as specified.
21M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of cement primer on walls. complete all as specified.
22M&L for rendering 15 mm thick in cement mortar (1:6) onbrick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified.
23M&L for preparation ofnewly plastered or unplastered/undecorated surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified.
24M&L rendering 10mm thick in cement mortar1(1:3) as in ceilings finished even and smooth (without using extra cement) complete all as specified.
25M&L for preparation ofnewly plastered or unplastered/undecorated surface of Ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified
26Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres complete all as specified.
27S&F for rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylinderical verticalwith closed top) hoisted and fixed in position all as per SSR Part I complete all as specified.
28Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 500 liters but not exceeding 1000 litres complete all as specified.
29S&F for rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylinderical verticalwith closed top) hoisted and fixed in position all as per SSR Part I complete all as specified.
30S&F fixed in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore and fixed, minimum weight of float valve 210 gms complete all as specified.
31Taking up or down15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
32Taking up or down20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
33S&F for medium grade galvanized steel tubing with all fittings & fixed complete to walls & ceiling or laid in floors 15 mm dia bore pipe (including in short length) complete all as specified.
34S&F for medium grade galvanized steel tubing with all fittings & fixed complete to walls & ceiling or laid in floors 20 mm dia bore pipe (including in short length) complete all as specified.
35S&F as in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified.
36S&F in repair 4mm thick sheet glassordinary quality and glazing with oil putty or wooden beads complete all as specified.
37S&F in repair fancy typeAngle stop cock with flange, 15 mm nominal bore, brass, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified.
38S&F in repair white vitreous China wash down water closet pan (pedestal pattern), and trap(excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc.complete all as specified.
39S&F in repair of plastic water closet sheet covers white closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device complete all as specified.
40S&F in repair vitreous china wash hand basin (flat back) of size 550x400mmincluding one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector,including cutting for and pinning in ends of brackets completeall as specified.
41S&F in repair pillar taps, cast copper alloy, with capstan heads, fancytype chromium plated, screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified.
42S&F in repair bib taps, long body,brass, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule orto GI socket complete all as specified.
43S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two brass nuts & rubber washers complete all as specified.
44S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic actiontype with inlet ball valve and float, handle with & including bracket andPVC flush pipe 32 mm borecomplete all as specified.
45S&F in repair PVC (SWR) floor trap plain with gratinghaving dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified.
46S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore complete all as specified and as directed.
47S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110 mm bore complete all as specified and as directed.
48S&F in repair PVC (SWR) bends any radius 110mm bore complete all as specified and as directed.
49S&F in repair PVC (SWR) bends any radius 75mm bore complete all as specified and as directed.
50S&F in repair PVC (SWR) junction single, (single T) equal or unequal 75 mm bore complete all as specified and as directed.
51S&F in repair PVC (SWR) junction single, (single T) equal or unequal 110mm bore complete all as specified and as directed.
52S&F in repair 110mm dia PVC (SWR) pipe and single socketed in any length with rubber ring joint fixed to wall complete all as specified and as directed.
53S&F as in repairPVC looking mirrorof selected quality of size 600 mm x450 mm on 4 mm thickwith framefixedscrew and cup- washers complete all as specified.
54S&F in repairtubular towel rail 20mm dia type brass chrormium plated 600mm long between flanges complete all as specified and as directed
55S&F in repair chromium plated shower roses 125 mm size with or without swivel joints of standard size including fixing to 15mm steel pipe or union complete all as specified.
56S&F in repair 25 mm outer dia medium weight pipe made out of stainless steel 304 grade, includingdecorative ornamental knobs at both ends and one set of ornamental decorative Stainless steel clamps tofixed towalls complete all as specified.
57S&Fin repair Corner glass shelf (with bracket) , fancy type with stainless steel railing fixed to wall with rawl plugs and chromium plated screws complete all as specified and directed.
58Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody for reuse or taking in schedule of credit and making good disturbed surfaces of walls, floors etc all as specified as directed.
59Dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store for reuse or taking in schedule of credit (Accessories or components to be provided free for replacement by department)
60Taking down unserviceable sub main wiring of any type/size including wires, conduits/battens etc complete all as specified and directed by Engr-in-Charge.
61Taking down unserviceable MCBDB"s/AC"s boxto deposit in store for keeping in safe custody for reuse or taking in schedule of credit of any size/rating complete all as specified and directed by Engr-in-charge.
62M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawn through in and including concealedPVC conduit size of not less than 20mm concecled in wall / surface including provn of pressed steel terminal boxof suitable size with 3mm thick plastic laminated sheet cover / modular white cover plate with frame as required module & modular metal flush box as required module for mounting switch, socket and fan regulator along with earth wire of PVC insulated, unseathed,1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and making good, disturb surface as it is, all asspecified and directed for the following. Note :- Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green
63One light pointcontrolled by one,one wayswitch.
64One ceiling fan/exhaust fan/Air ciculator /bell point controlled by one way switch.
65One light point controlled by 2, 2 way switch.
66Socket 3 pin 5 Amps on the same board, complete all as specified.
67Socket 3 pin 5 Amps on independent board , complete all as specified and directed.
68M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 2.5 sqmm drawn through in and including concealedPVC conduit size of not less than 25mm concecled in wall / surface including provn of pressed steel terminal boxof suitable size with 3mm thick plastic laminated sheet cover / modular white cover plate with frame as required module & modular metal flush box as required module for mounting switch, socket and fan regulator along with earth wire of PVC insulated, unseathed,1100 V grade cable multi stranded copper conductor of size 2.5 sqmm and making good, disturb surface as it is, all asspecified and directed for the following. Note :- Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green
69M&L in replacement for sub main wiring with two single core 2.5sqmm stranded copperconductor PVC insulated and unsheathed cable ISI marked in 25 mm dia, medium grade, PVC conduit concealed in wall for sub main connection including1.5 Sqmm PVC insulated unsheathedcopper conductor ISI marked as earth wire complete all as specified and directed by Engr-in-charge.
70All as per item No 69 herein before but submain wiring with 2x4Sqmm and 1x2.5Sqmm Complete all as specefied and directed.
71All as per item No 69 herein before but submain wiring with 2x6Sqmm and 1x4Sqmm Complete all as specefied and directed.
72All as per item No 69 herein before but submain wiring with 2x10Sqmm and 1x6Sqmm Complete all as specefied and directed.
73S&Ffor switch socket outlet 5 Amps, 5 pin flush type, 240 volts. with polycarbonate body. complete all as specified and directed..
74S&Ffor switch socket out let, 6 pin 5/15 Amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body.complete all as specified and directed.
75S&Ffor switch piano flush type single pole one way 5 Amps 240 volts with polycarbonate body complete all as specified and directed..
76S&F for switch piano flush type singlepole two way 15 Amps 240 volts with polycarbonate body complete all as specified and directed..
77S&F for bell push flush type single pole one way 5 Amps 240 volts with polycarbonate body complete all as specified and as directed.
78S&F for bell electric heavy duty Ding Dong type 230 volts single pole complete and all as specified. complete all as specified and as directed
79S&F For ceiling fan regulator stepped electronic type 300 watt rating, 230 volts with polycarbonate bodyall as directed.
80S&F Modular switch 1 way 6A, 1 module all as specified and directed
81S&F Modular switch 1 way 16A, 1 module all as specified and directed
82S&F Modular switch 2 way 6A, 1 module all as specified and directed
83S&F for modular socket outlet6A 2/3pin combined 2 module complete all as specified and directed..
84S&F for modular socket 6A /16A 2/3pin combined 2 module complete all as specified and directed.
85S&F Modular fan step regulator, 120W 2 module all as specified and directed
86M&L for ceiling rose 3phase/PVC polycarbonate isolated body complete all as specified and directed
87S&F modular bell push 6A, 1 module complete all as specified and directed
88S&F sheet metal enclosure single pole and neutral two pin and earth plug and socket complete with one double pole MCB SP 20 Amps for geyser complete all as specified and as directed.
89S&F in replaceent of MCB DB sheet enclosure single pole and neutral 240V with 200 Amp suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricatedAcrylic double door complete confirming to IP 43with enclosure blank plates for unusedway suitable for 8 way complete all as specified and directed .
90All as per item No 89 above but 4 way, complete all as specified and directed.
91All as per item No 89 above but 12 way, complete all as specified and directed.
92S&F in replaceent of MCB DB sheet enclosure Triplepole and neutral 415V with 200 Amp suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricatedAcrylic double door complete confirming to IP 43with enclosure blank plates for unusedway suitable for 4 way complete all as specified and directed.
93S&F MCB, single pole & neutral, 240 Volts40 to 63 Amps,10KA B series complete all as specified and directed .
94S&F MCB, single pole, 240 Volts (05 to 32) Amps,10KA, B series complete all as specified and directed .
95Supply and fixLED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completeall as specified and as directed .
96Supply and fixLED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size completeall as specified and as directed .
97S & F Lamp holder insulated body with back plate for batten fittings.with polycarbonate body complete all as specified and as directed.
98M&L for earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI wire 4 mm Dia as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified includingprovision 20 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation andearth work & connecting the earthing to an earthing test point complete all as specified & directed .
99NOTE: (i) The concrete pit shall be PCC 1:3:6 type C-140 mm thick pre cast cover slab of RCC(1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cost iron cover shown in the electrical plate No.3 of MES SSR Part -1 (ii) item includes the cost of 7.5 m GI pipe for protection of GI wire.(iii) PCC pits extra cost of addtional length of watering pipe,bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length Galvisedwire 4 mm dia.
100S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 6sqmm galvanised iron or steel wire complete all as specified and directed
101S&F MCCB, three pole & neutral, 415 Volts63-100 Amps,25KA complete all as specified and directed .Make:- Havells Or equvalant in Hager/ Legrand
102S&F LED security light fitting 35/36 Watt, having uniformty ratio 0.25 , high pressure die cast aluminium housing , heat resistant toughened glass frame , IP-65 protection complete with lamp & connected items and connection with suitable cable from celing rose to light fitting and fixing on GI pipe bracket made out of suitable dia GI pipe medium grade 1.2 m long bend to shape and fixed on wall with flat iron clamps nut, bolts washers etc specified and directed
103Supply and fix in repair capacitor 2.5 mfd,400 volt ,50 hz complete all as specified and as directed.Make : Tibcon
104Supply and fix in repair capacitor 4 mfd,400 volt ,50 hz complete all as specified and as directed Make : Tibcon
105Supply and fix in replacement steel body Exaust fan of 300 mmsize with louver complete all as specified & directed by Engr-in-Charge
106S&F in replacement of heating element 2000 watt capacity triangular typecomplete all as specified and as directed .
107S&F in replacement of heating element 1500 watt capacity triangular typecomplete all as specified and as directed .
108S&F in replacement of heating element 1500 watt capacity circular typecomplete all as specified and as directed .
109M&L for rewinding of following fans with same gauge of super enameled copper wire complete varnishing ,baking ,connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with nots /bolts/washer /split pin and blade screw s etc testing ,complete all as specified and directed.NOTE: (i) Spare parts like bearing,capacitor,bushes if requiredwill be measured and paid separately. (ii) The rates shall be deemed to include dismantling of fan and reassembling after repair /replacement of worn out parts
110Ceiling fan 1200 mm sweep
111Exhaustfans 450 mm sweep
112Exaust Fan 300 mm Sweep
113Supply and fix in repairball bearing suitable for the following fans : Make :-NBC/SKF/Tata
114Ceiling fan 1200 mm sweep
115Exhaustfan 450 mm sweep
116Exaust Fan 300 mm Sweep
117M&L in replacement for sub main wiring with two single core 2.5Sqmm multi stranded copperconductor PVC insulated and unsheathed cable ISI marked drawn throughin and including 25 mm dia, medium grade,steel conduit concealed in wall for sub main connection including1.5 Sqmm PVC insulated unsheathedcopper conductor ISI marked as earth wire complete all as specified and directed by Engr-in-charge.
118S&F in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed. Make : CromptonCat Part No.LCTLRN-36-CDL or equivalent in Wipro,Philips.
119S&F in replacement of Casing capping double lock type supper qualitysize 20 mm width ISI marked with fixing accessoriescomplete all as specified and directed.
120S&F in replacement of rigid non metalic PVC medium grade conduit of20 mm bore including boxes, tees,bend and fixing accessories such as copper,lock nut, saddles,pipe huck etc complete all as specified and directed by Engineer in Charge.
121S&F in replacement of PVC gang box suitable for one switch and socket 5 Amps complete with screw and necessary arrangement complete all as specified and directed.
122All as per item No 114but suitable for one switch and socket 15 Amps
123Complete removal of existing treatment from external surfaces of walls, parapets, fins/ facia, chajjas by wire brushing and washing, rubbing down and stopping of surfaces and levelling/ edging the disturbed places/ edges using necessary filling compound ofcement based putty to obtain smooth regular/ even finish surface using sand paper and applyingtwo coat of Weather Exterior Emulsion paint complete all as specified and as directed.
124M&L Bees-wax polishing on surfaces of any description, width or girth including cleaning and preparing the surface complete all as specified and as directed.
125M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior emulsion paint over a coat of primer complete all as specified and directed.
126M&L for 75 mm thick cement concrete (1:4:8) type D-2 with using 40 mm graded stone aggregates) asin sub base of flooing etc complete all as specified.
127M&L for 40mm thick cement concrete type B-, 1:2:4 (20mm graded aggregate) as in flooring finished even and smooth without using extra cement complete all as specified
128Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified.
129M&L brick work with sub class ‘B’ bricks old size straight or curved on plan exc 6.0 m mean radius built in cement mortar 1:6 complete all as specified.
130Dismantling of existing water tanks of steel/PVC/AC of capacity5000 litres & S&Frotational moulded polyethylene water storage tanks 5000 ltrs capacity (cylinderical verticalwith closed top) hoisted and fixed in position complete all as specified.
131Taking downchowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed.
132All as per item No. 124 here-in-before butexc 1.5 Sqm and not exc 4 Sqm each complete all as specified.
133Taking down shutter of any description exc 1 Sqmand n exc 2 Sqm and removing from site complete all as specified.
134S&F factory made 35mm thickflush shutters , solid core construction with block board core and plywood face pannel commercial type on both faces complete all as specified.
135S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified and as directed.
136S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified.
137S&F 150 mm size extruded aluminium alloy handles fabricatedtype anodised and fixed complete all as specified.
138Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
139S&F sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads complete all as specified.
140S&F forPressed steel frames 105X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified.
141M&L preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
142S&Fvitreous china bowl urinal flat back of size 465 x 355x 265 mm, white including grating and union for discharge pipe,includingwaste pipe and including fixing plugs beading urinal against wall in CM 1:2, securing urinal to plugs with brass screws 60 mm long, pointing around urinal in white cement specified.
143S&F in repair door seals made of aluminium strip powder coated 20 mm wide and provided rubber/ cotton mat lining fixed with screws to door shutters up to 1 mtr width opening complete all as specified.
144S & F in repair drapery rod 25 mm dia high strength aluminium rod with powder coated paint of thickness 40/60 microne of wood finish and one set of ornamental decoative finish woodenclamps all accessories complete all as specified.
145Taking down of aluminium frame/doors/windows from site dismantling aluminium structure such as glass, rubber beading aluminium clips complete all as specified.
146S&F powder coated Anodised aluminium frame for partition, doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
147S&Fpowder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door,100 mm longhinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified.
148S&Fpowder coated Anodised aluminium window and ventilator shutters side hung type without sash bar, aluminium sections weighing 0.55 kg/m including necessary joining, cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as hinges type B-21 100 mm long - 2 Nos, suitable size handle -1 No & tower bolt 100 mm -1 No complete all as specified.
149M&L for 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square complete all as specified.
150S&F 9 mm thick prelaminated both side particle board exterior grade in bottom panel of Aluminium door including rubber gasket, aluminium glazing clips complete all as specified.
151S&F fabricatedanodized aluminium grill of size 75x100mm, using 5 mm dia bars fixed to frames using U/V section runners complete all as specified.
152S&F in repair Mortice lock, vertical type of brass 100 mm 4 Levers with duplicate keys complete all as specified.
153S&F in repair aluminium (Die cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified.
154S&F in repair 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified.
155S&F 100 mm Hasp and staple, safety type,brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified.
156S&FContinuous (piano) hinges, mild steel, bright finish or electrogalvanised 40 mm Width of flaps (when open) in mm.
157S&F as in repair aluminium anodised tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified.
158Dismantling ceiling board (fiber, pulp insulation etc) or insulation boards/slabs etc including grid work/wooden or aluminium frame works, cover fillet etc complete all as specified.
159M&L for clip in type armed strong metallic powder coated 0.5mm thick ceiling with GI framework made of standard Tee, angle or any other section as in grid type ceiling framework as approved by GE.Ceiling shall be hanged to roof trusses / purlin rafters with the help of GI wire not less than 4mm dia at an interval n exc 1m , the size of the metallic powder coated ceiling tiles 600mm x 600mm complete all as specified.
160S&F in repair 610 mm long PVC waste pipe flexible type 25 mm dia suitable for couplings 32 mm & 40 mm dia complete all as specified.
161M&L for Carry out "B" check from authorised rep or service engineer from the manufacturer of DG set of 200 KVA,capacityMake : Cummins (including the cost of the following sparesall as per OEM instructions and directed) :- (a) S & F in repair lubrication oil filter (b) S & F in repair by pass filter (c) Checking of hydraulic governer (d) Checking and toping up of coolant (e) S & F in repair fuel filter (f) S & F in repair air cleaner element . (g) Cleaning radiator complete set
162S&F Solenoied switch sutaible for 200 KVA DG Set complete All as specified & directed by engr-in-charge
163S&F of Ring gear of Flywheel suitable for DG set up to 200 KVA complete All as specified & directed by engr-in-charge
164Supply and fixing in replacement of AVR S/F VARIABLE SPEED DCDGsuitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage suitable for DG set of 200 KVA complete all as specified and directed by Engineer -in-charge.
165M&L for disconnected and opening of self starter assemlly 12/24 volt for repair from DG set up to 200 KVA & repair unserveceable part of self starter suitable size as required on sitecomplete all as specified and directed. Note :- Rate are deemed tobe include all worn out part including gear & winding complete all as specified
166Supply only the following items of DG Set of various capacity :-
167Battery terminal, lug, bolts type suitable for heavy duty battery.
168Battery leads for copper conductor multiwired 70 Sqmm Single Core.
169M&L for Dismantling existing U/S battery charger & S/F of SMPS type battery charger suitable for 12 V DC with auto cut off from trickle to boost alongwith AC lead to charge the battery when DG Set is not in use complete all as specified & directed by Engineer Incharge.
170S&F V belt for fan pulley (set of 2 Nos) for DG set upto 200 KVA DG Set complete all as specified.
171S&F V belt for alternator and water pump assembly for DG set upto 200 KVA complete all as specified.
172S&F Fuel hose pipe from fuel filter to fuel pump for DG set upto 200 KVA, complete all as specified.
173S&F Fuel pipe from fuel tank to fuel filterfor DG set upto 200 KVA, complete all as specified.
174Material & labour for carrying out complete overhauling / servicing of DG set (200 KVA) panel / AMF panel / control panel,including checking and rewiring faulty electrical circuit using 1.5 sqmm FRLS copper conductor, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation, complete all as directed.
175Supply and fixing of "under/over voltage relay, 3 phase, 415 volts", for DG sets of capacity upto 200 KVA complete all as specified and directed by engineer-in-charge.
176Supply and fixing in replacement of Lead acid maintenance free Battry12 Volts 180AH of existing type & size suitable for DG Sets . Make : EXIDE/Amoron including initial charging.
177Technicianfor attendingofanybreakdown of standby supply in any location ,whenever required round the clock ,rectify the fault and restore the standby supply within three hour after receipt of complaint of any nature i.e. Engine, alternator,control panel,AMF panel, display board etc . Note -(i) The cost ofreplaced spare parts will be paid and measured seperatly.(ii)If complaint is not attended by contractorwith in five hour the penality of Rs 500 / per hourto be imposed and amount of penality will be deducted from RAR. (iii) Thecost of transportation (to and fro) for all kind ofnecessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specifythe telephone no who willreceive the complaint round the clock.
178Material & labour for opening / taking out of injector of DG set of any type/make and capacity200 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the allignment, making properfuel connection, testing for smooth opreatio complete all as directed.
179S&F in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set connection testing complete all as specified and directed.
180Material & labour for complete overhauling,servicing of turbo charger, opening /taking out of turbo charger of DG set of 200KVA capacity ,disconnection of air supplyconnection pipe etc, including replacement of turbo charger repair kit, calibration/ testing of turbo charger system complete and re-assembling the same ,fitted with DG set properly in original position, checking the allignment, making proper all connection, testing for smooth opreation from authorised rep or service engineer from the manufacturer complete all as directed.
181M&L for capacity 200 KVA DG set complete descaling of cooling system by radiwash with two times circulation of radiwash by means of running of engine & cleaning of fan blades, crankcase breather, radiator and its fins by means of high pressure air or water complete all as specified and directed.
182M&L for Dehydration including filtration and cleaning of Transformer oil by dehydrating machine incl testing of sample before and after dehydration and filtration and replacement of silica gel all as specified and directed NOTE:- Contractor hasto arrange the dehydration machine and testing kit withoutany extra cost to the dept. Test report to be submitted after completion of job. (Transformer 415 KVA)
183Supply & Filling /pouring of up to the appropriate level Transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and as directed :- NOTE:-Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site
184M&L for Comprehensive maintenance of transformer by isolating ,disconnecting of input/output ,supply cable, opening of top of transformer, detecting of fault ,u/s component, cleaning of serviceable parts/ component ,includingreplacement of worn out spare parts, finding of oil leakage& sealing it by oil seal or gas welding etc if any all as specified and directed. (Transformer 415 KVA)
185Taking out VCB trolley from HT control panel 11 KV 3 phase 800 Amp , Breaking capacity 20kA (Make :- crompton greaves) and cleaning the trolley with CRCremoving all dust , carbon etc greasing the mechanical parts gears ,lever charging male female contacts and spring holders all as specified and as directed.
186Material and labour for sevicing of VCB panel & calibration ofnumerical relay as per existing load for earth fault , over current and short circuit ,including setting the relay on required electric load and testing on earth fault and short circuit and over load with the help of relay testing kit complete in all respect all as specified and as directed.
187M&L for Comprehensive maintenance of RMU by isolating ,disconnecting of input/output ,supply cable, opening of RMU, detecting of fault ,u/s component, cleaning of serviceable parts/ component ,includingreplacement of worn out spare parts, finding of fault if any complete all as specified and directed.
188S&F in transformer breathers sillica gel (orange) for effective breathing & to protect transformer oil from moisture Complete all as specified & directed by Engr-in-Charge
189Technician for attendingofanybreakdown of HT/LT supply due to fault in VCB or transformer, whenever required round the clock ,rectify the fault and restore the standby supply within four- fiveHrs after receipt of complaint of any nature. Note -(i) The cost ofreplaced spare parts will be paid and measured seperatly. (ii)If complaint is not attended by contractorwith in five hour the penality of Rs 500 / per hourto be imposed and amount of penality will be deducted from RAR. (iii) Thecost of transportation (to and fro) for all kind ofnecessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specifythe telephone no who willreceive the complaint round the clock.
190M&L for Comprehensive maintenance of Main LT panel & cubical type indoor automatic capacitor panel by isolating ,disconnecting of input/output ,supply cable, detecting of fault ,u/s component in panel ,cleaning of serviceable parts/ component ,includingreplacement of worn out switches LED indicator, spare parts, Welding of Panel door & replacement of Door lock, replacement of old wiring with 2.5 sqmm to 6 sqmm etc, if required all as specified and directed.
191Supply and fixing LED surface light (Square) SSk-SDS-30 W-N, size 300X300X40 mm input power 30watt Lumens> 2400, housing pressure die-cast aluminium Make: Syska or Equivalent model in Bajaj /Havells /Cromptons
192Supply and fixing in existing position LED , Post top fittings powder coated aluminium, IP 65 protection cat part no- PGR0201009, cataloguereference PCGLP01400, 40 Watt , CCT 5700 k , HSN code 9405 Make: Polycab or equivalent make in Bajaj/Havelles/CGLocation: in/out gate
193Supply and fixing in existing position LED , Post top fittings powder coated aluminium, IP 65 protection cat part no- PGR0201007, cataloguereference PCGLP01250, 25 Watt , CCT 5700 k , HSN code 9405 Make: Polycab or equivalent make in Bajaj/Havelles/CG Location: Front Boundary wall
194Supply and fixing in existing position LED FLAT flood light powder coated aluminium, IP 65 protection cat part no- SSK-BLS-F-150W, Wattage-150 ,input voltage AC 90-300V ingress protection IP 65 , power factor> 0.9 ,housing pressure die cast aluminium Make: Syska or Equivalent model in Bajaj/Havells/Cromptons Location: Front side of bldgs
195Supply and fixing in existing position LED street lights-SLF-CF seriescat part no- SSK-SLF-CF-120W, Wattage-120WIP 65 protction . Make: Syska or Equivalent model in Bajaj/Havells/Cromptons Location: Backside of bldgs
196Supply & fixing LED deep down light (round)series cat part no- SSk-DLC-6"- 20 W, wattage-20 watt. Make: Syska or Equivalent model in Bajaj/Havells/Cromptons. Location: Main entry porch
197Supply & fixing surface mounted LED bulk head luminaire with ABs body & polycarbonate diffuser product code 0101316, wattage 10 watt HSNcode 9405 . Make: Polycab or Equivalent model inBajaj /Havells/ Cromptons Location: Both side passage & main bldgs
198S&Fbracket made of GI-pipe light grade fitting 1.2 m in length and fixed on wall including necessary MS clamps nuts, bolts etc complete, all fixing materials included in the unit rate.
199Supply and fixing in existing position LED T-5Battencat part no- SSK-T5-SQ2201-AL input power-22W, size 22X36X1260(L)mm, IP-20 aluminium housing, Lumens>1900 . Make: Syska or equivalent in Philips /Wipro /CG Location: VIP Bed Rooms
200Supply and fixing in existing position LED T-5Battencat part no- SSK-T5-SQ1201,input power-12W, size 22X36X600 L)mm, IP-20 aluminium housing, Lumens>1200 .Make: Syska or equivalent in Philips/Wipro/CG Location: VIP Guest RoomToilet
201Supply and fixing in existing position LED surface light(Square)cat part no- SSK-SDS-18W-Ninput power-18W, size 225X225X40 L)mm, IP-20 pressure diecast aluminium housing, Lumens>1440 . Make: Syska or equivalent or equivalent in Philips/Wipro/CG Location: VIP Guest RoomToilet
202Supply and fixing in existing position LED surface light(Square)cat part no- SSK-SDS-12W-Ninput power-12W, size 172X172X40 L)mm, IP-20 pressure diecast aluminium housing, Lumens>900 . Make: Syska or equivalent or equivalent in Philips/Wipro/CG Location: VIP Guest Room balcony
203Supply and fixingLED Backlite panel (2x2) cat part no- SSK-TVP-6060-36 W , size 600X600X50 (H) mm, Lumens>3700, IP-20, sheet aluminium housing complete with all fixing arrrangements/materials required at site including making good of distrubed surface for matching with distrubedexisting surface inculding POP/Puttyand white wash as per direction by Engr-in-Charge. Make: Syska or equivalent in Philips/Wipro/CGLocation: Director office F/F
204Supply and fixing in existing position LED surface light(Square)cat part no- SSK-SDS-30W-Ninput power-30W, size3002X300X40 L)mm, IP-20 pressure diecast aluminium housing, Lumens>900, Make: Syska or equivalent in Philips/Wipro/CG Location: VIP Guest Room balcony Note: All the distrubed surface shall be made as good as existing including all materials required at site: i.e POP/Putty/White wash /Distemper and no extra amount will be paid on this account.
205Supply and fixing in LED T-8 batten fitting Cat part no SSK-TL-22W-F, input power 22 w, size 26.5X1200mm, input Volatage AC 90 to 300V , Lumens>2200, Extruded aluminium housing.
206Supply and fixing LED surface light Square type Cat part No-SSK-SDS-22W-N, size 225X40MM Lumens>2400, Preesure die cast aluminium.
207S&F in replacement ofsocket outlet 2in1, 6 pin 15/5 Amps flush type
208S&F in replacement of switch piano, flush type, 15 amps, single pole, one way
209S&F inreplacement of sheet metal enclosure with socket plug top and MCB single pole and neutralwith two pin and earth plug with one SP MCB 20 Amp 240 volt complete all as directed.
210S&F in replacement of MCB SPN32Amps, 10 KA,240V, 50Hz, "B" Series complete all as specified and as directed.