| 1 | Picking up and removing old bituminous layer or sand sealing coat from old black topped surface and cleaning the exposed surface by scraping and stacking the material as directed.(a) By manual means :.From 50 mm to 100 mm thick. |
| 2 | Cleaning and removing conservancy garbage mixed withrubbish & other filthy materials from the road side flank,drain and compound including cutting, loading, unloading to and from truck or cart by Mathor labour & removing thesame to any distance. |
| 3 | Providing and applying tack coat with Cationic Bitumen Emulsion of approved grade conforming to IS: 8887-1978 on the prepared surface cleaned with Hydraulic broom, moistening the surface including cost and carriage of emulsion, hire charges of machinery and labour, cost of fuel and lubricants all complete as per Clause 503 of Specifications for Road & Bridge Works of MoRT&H (5th revision).(i) On Bituminous Surface(Using Bitumen Emulsion at the rate of 0.20 to 0.30 kg per sqm.) |
| 4 | Providing and Laying Bituminous Macadam with Mobile Hot Mix Plant (Light Duty) using approved crushed aggregates of specified grading as per table 500.4 premixed withh Bituminous binder, transported to site laid over a previously prepared surface at specified laying temprature by means of approved and sutaible arrangements to the required grade,...................................B. For grading II (19 mm nominal size, 50-75 mm thick) |
| 5 | Providing, laying and rolling of Open - graded premix surfacing of 20 mm thickness composed of 13.2 mm (@ 0.018 m³ per m²) and 11.2 mm (@ 0.009 m³ per m²) size stone aggregates, including thoroughly cleaning of the surface, screening, cleaning and pre-heating stone chips and fully pre-coating the same either using viscosity grade paving bitumen or cut-back or emulsion, carrying the mixture by any suitable arrangements, laying the mixture uniformly over the surface, including line, grade and level to serve as wearing course on a previously prepared base, including mixing in Mobile Hot Mix Plant (Light Duty) and thoroughly rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades including the cost and carriage of stone chips and matrix, heating the matrix, preheating the aggregates to required temperature and includingthe hire charges of Mobile Hot Mix Plant (Light Duty)and other machinery, pay of operators, cost of fuel and lubricants etc. complete to be followed by seal coat of either Type A or Type B as per Technical Specification Clause 508 for Rural Roads of MORD |
| 6 | Providing and laying Mastic Asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-29 using approved coarse aggregate, fine aggregrate,filler material and bitumen, prepared by using mastic cooker including cost and carraige of all ingredients, cost of heating aggregates and binder, mixing in specified proportions conforming to approved job mix formula and laid to required level and slope after cleaning the surface, compacting, sealing the construction joints and surface finishing conforming to specification including providing antiskid surface with bitumen pre-coated fine-grained hard stone chipping of 13.2mm nominal size at the rate of 0.005cum per 10 sqm and at an approximate spacing of 10 cm center to center in both directions, pressed into surface when the temparature of surfaces not less than 100° C, protruding 1mm to 4mm over mastic surface, including the hire charges of all tools and plants and machinery, pay of operators, cost of fuel and lubricants and all other incidental charges and quality control all complete as per clause 516 of specification for road & bridge works of MoRT&H (5th revision)(i) 25 mm thickness |
| 7 | Relaying disturbed kerb stone on new lime concrete (18 : 36 : 100) bedup to 75 mm thick. |
| 8 | Relaying disturbed channel stone on new lime concrete (18 : 36 : 100)bed up to 75 mm thick. |
| 9 | Road Marking with Hot Applied ThermoplasticCompound with Reflectorising Glass Beads onBituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes complete as per Clause803 of Specifications for Road & Bridge Works ofMoRT&H (5th Revision). |
| 10 | Painting the vertical end faces of posts, wheel guards or railing or parapet with alternate bands of different colours as directed by the Engineer-in-charge with approved synthetic enamel paint. Two Coats |
| 11 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)25 mm to 30 mm shuttering without staging in foundation |
| 12 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.For works in foundation and upto roof of ground floor/upto 4 mJSW/SHYAM/JSPL |
| 13 | Plaster (to wall, floor, ceiling etc) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging where necessary (G.F.)[excluding cost of chipping over concrete surface]15mm thick 4:1. |
| 14 | Neat cement punning about 1.5mm thick in wall dado, window sills, floor, drain etc. |
| 15 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.Pakur VarietyIn Ground Floor |
| 16 | Brick work with 1st class bricks in cement mortar (1:4)(a) In foundation and plinth |
| 17 | Supplying fitting and fixing on wall a white Marble Plaque of size 900mm x 750mm x 18mm with engraved letters….. as perdirection of the Engineer-in-Charge. (The rate is inclusive of cost of reinforcement, concrete, shuttering, nuts & bolts, washer etc. complete.) |
| 18 | Supplying, fitting and fixing in position reinforced cement polymer concrete manhole /gully pit cover with matching frame.As per I.S-12592(M.D)(i) 35 MT load bearing capacity round manhole cover provided with two lifter hooks fitted with matching frame of sizeCover: 700 mm X 100 mmFrame: 910 mm X 185 mmopening: 560mmWeight: 245 kg (approx) |
| 19 | GST @ 12%on sum of item no 1 to 18( i.e on Amount Rs 7312818.72) |
| 20 | Cess @ 1% on sum of item no 1 to 19 ( i.e on Amount Rs 8190356.97) |