Military Engineer Services-MES has published Repair / Maintenance Of Ug Cable And Connected Service Under Age E / M Area At Morar Cantt Underge Gwalior. Submission Date for this Tender is 27-08-2022. Cable Laying Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 06-Aug-2022 | Corrigendum 1 | Terms and Conditions | 22-08-2022 |
2 | 17-Aug-2022 | Corrigendum 2 | Date | 27-08-2022 |
3 | 17-Aug-2022 | Corrigendum 2 | Other | 27-08-2022 |
Sl. No. | Item Description |
1 | Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and as directed. |
2 | Excavation in trenches n exc. 1.5 m wide andexc 1.5m deep and n.exc 3.0 m deep for foundation beyond the first 1.5 m ,etc. or for shafts, wells cesspits, manholes, pier holes, etc. n exc.10 sq m on planand getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge. |
3 | Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed. |
4 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed. |
5 | M&L for sand cushioning in trenches for cable protection including consolidation complete all as directed. |
6 | M&L for laying un-reinforced precast concrete cable cover factory made, class LV, Type 1, flat size 250mmx150mmx40mm complete all as specified and directed by Engineer-in-Charge. |
7 | M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete all asspecified and directed. |
8 | M&L for PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete all asspecified and directed. |
9 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded BT stone aggregate as in bed block for hold fast or coping including necessary form work complete all as specified and directed by Engineer-in-Charge. |
10 | M&L, Steel tublar swaged poles, complete with cast iron base plate, finials taper plug , bolts, nuts & screws as specified type 410 SP-31 (9.00 mtr long). Note : Earth work and PCC shall be measured & paid separately under respective items . |
11 | M&L for fixing of ACSR conductoron existing or new poles all as directed. |
12 | Restringing and stretching of existing sagged LT ACSR conductor of any size on OH electric line of any length on existing poles after disconnection of binding wires (dismantling & taking down) service connection etc and making, binding and service connection complete all as directed. |
13 | M & L for GI Pipe light grade complete with fittings laid in floor/ trenches/ wall as cable protection of 100 mm dia all as specified and directed. |
14 | All as per item No. 13 but size 80 mm dia. |
15 | All as per item No. 13 but size 40 mm dia. |
16 | Supply, laying, jointing and testing, XLPE insulated, armoured,heavy duty, electric LT UG cable with multi stranded aluminium conductor, 1100 Volts grade, of size 3.5 core 400Sqmm |
17 | All as per item No. 16 but 300 Sqmm 3.5 core. |
18 | All as per item No. 16 but 240 Sqmm 3.5 core. |
19 | All as per item No. 16 but 185 Sqmm 3.5 core. |
20 | All as per item No. 16 but 120Sqmm 3.5 core. |
21 | All as per item No. 16 but 95 Sqmm 3.5 core. |
22 | All as per item No. 16 but 70 Sqmm 3.5 core. |
23 | All as per item No. 16 but 50 Sqmm 3.5 core. |
24 | All as per item No. 16 but 35 Sqmm 3.5 core. |
25 | Refixing/ repositioningPCC/ Steel tublarpoles incl erection in true vertical position complete.(Note - Excavation & PCC foundation if reqd will be measured and paid seperately). |
26 | S& F Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 550 volts grade . |
27 | S& F Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers,insulator bolts, washers and nuts, height 50mm dia 65 mm for 550 volte grade. |
28 | M&L for loop type insulator, vitreous porcelain white ,brown or green large size over all dimension 90 X 140mm, clearance of the hole 25.5mm for stay assembly complete all as specified and directed. |
29 | Fixing only of cross arm of any size on existing or new poles complete after drilling, cutting, scrabbing & 2 coat of aluminium painting etc retrieved against above said item complete. |
30 | M & L for cross arms, bracing, supports, clamps and back plated fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms complete all as specified and as directed. |
31 | M&L for stay assembly 16 mm dia rod complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps, excavation and concrete measured separately)all as directed. |
32 | M&L for Earthing of machinery/equipment Installed at power house/substation, using 32 x 6 mm galvanized MS strip and MS galvanized plate of size 600 x 600 x 6 mm ,as earth electrode |
33 | M & L Earthing for poles & other machinery/equipment using 4 mm GI wire as earthing lead and MS galvanized plate of size 60 cm x 60 cm x mm, as earth electrode. |
34 | Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated using 32 x 6 mm galvanized MS strip |
35 | M & L in replacement of MCCBs 400 Amps, 415 volts, 4 pole rupturing capacity 36 KA in existing LT panel including making existing electrical connection as per existing system all as specified and directed. |
36 | M & L in replacement of MCCBs 250 Amps, 415 volts, 4 pole rupturing capacity 36 KA in existing LT panel including making existing electrical connection as per existing system all as specified and directed. |
37 | M & L in replacement of MCCBs 200 Amps, 415 volts, 4 pole rupturing capacity 36 KA in existing LT panel including making existing electrical connection as per existing system all as specified and directed. |
38 | M & L in replacement of MCCBs 160 Amps, 415 volts, 4 pole rupturing capacity 36 KA in existing LT panel including making existing electrical connection as per existing system all as specified and directed. |
39 | M&L Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150 sqmm |
40 | M&L Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185sqmm to 300sqmm |
41 | Supply, laying, jointing and testing, XLPE insulated, Unarmoured,heavy duty, electric LTcableAluminium conductor, 1100 Volts grade, of size 1 core 95Sqmm |
42 | Supply, laying, jointing and testing, XLPE insulated, Unarmoured,heavy duty, electric LTcableAluminium conductor, 1100 Volts grade, of size 1 core 120Sqmm |
43 | M&L LTCable insulation protection sleeveHeat shrink type singalCroe sleeve forLT Cableof size 70 sqmm to 185 sqmm . |
44 | M&L LTCable insulation protection sleeveHeat shrink typesingal Croe sleeve forLT Cableof size 240 sqmm to 300 sqmm . |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy