}

Supply Of Implants , D.H.S. Plate Long / Short Barrel ( 38 / 25 Mm ) With Round, D. C., Combi Hole 1250, 1300, 1350, 1400 Angle; 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18 Holes , D.H.S Screw 22Mm / 16Mm Threading W, sagar-Madhya Pradesh

Government Medical College-GMC has published Supply Of Implants , D.H.S. Plate Long / Short Barrel ( 38 / 25 Mm ) With Round, D. C., Combi Hole 1250, 1300, 1350, 1400 Angle; 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18 Holes , D.H.S Screw 22Mm / 16Mm Threading W. Submission Date for this Tender is 18-08-2022. Bath and Body Tenders in sagar Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33292892
Supply Of Implants , D.H.S. Plate Long / Short Barrel ( 38 / 25 Mm ) With Round, D. C., Combi Hole 1250, 1300, 1350, 1400 Angle; 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18 Holes , D.H.S Screw 22Mm / 16Mm Threading W
Open Tender
Indian
Madhya Pradesh
sagar
18-08-2022

Tender Details

Supply Of Implants , D.H.S. Plate Long / Short Barrel ( 38 / 25 Mm ) With Round, D. C., Combi Hole 1250, 1300, 1350, 1400 Angle; 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18 Holes , D.H.S Screw 22Mm / 16Mm Threading With Compression Screw ( Top-Bolt ) . ( 36 Mm ) 50 To 115 Mm, In 5Mm Increments , Pediatric D.H.S. Set , D.C.S Plate ( 950 ) With Round, D. C., Combi Holes 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20, 22, 24 Holes , Angle Blade Plate ( 950 ) With Round, D. C., Combi Holes, Blade Size 50, 55, 60, 65, 70 & 75 Mm And 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18 Holes , Trochanteric Stabilisation Plate To Be Used With Dhs , Distal Femur Locking Compression Plate ( Right & Left ) Anatomical Pre-Shaped & Contoured With Self-Tapping Locking Head Screws; With Round Locking Holes For Metaphyseal Portion Of Plate & Combiholes For Shaft Of Plate. , Medial & Lateral Proximal Tibial Buttress Plate ( T- & L- Shape ) - As Per Ao Specifications. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Proximal Medial & Lateral Tibial Plate 3.5 Mm ( Right & Left ) Anatomically Pre Shaped And Low Profile. Two Different Plate Design For Left And Right Side With Indication On Side Of Plate. Plate Should Have 2 Mm Holes Forproximal Fixation With K-Wire And Sutures For Meniscal Repair. Holes Should Accept 3.5 Mm Locking Head Or 3.5 Mm Standard Cortical Screws From 4 To 20Holes With Increment Of 2 Holes. , Proximal Medial / Lateral Tibial Locking Plate For 4.5 Mm Screws Anatomically Pre Shaped And Low Profile Design, Two Different Plate Design For Left And Right With Indication On Plate. Round Metaphyseal Locking Holes And Combi Holes In Shaft Portion For Locking And Standard Screws. Different Angulation In Proximal Part Of The Plate To Avoid Primary And Secondary Loss Of Reduction. Should Be Compatible For Less Invasive Technique Holes Should Accept 5 Mm Locking Head Or 6.5 Mm Standard Cancellousl Screwsfrom 5 To 13Holes , Hockey Plate For Tibia ( Right & Left ) 5, 7, 9, 11, 13, 15, 17 Holes , Contoured Medial / Antero-Lateral Plate For Lower End Tibia 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Distal Medial Tibial Locking Plates 2.7 / 3.5 Mm. Anatomically Pre-Shaped And Low Profile And Specific For Right And Left Side With Indication Of Side On Plate, Compatible With Less Invasive Fixation. Rounded Edgesscrew Heads Should Be Received Into Distal Section Of Plate To Allow Multiple Locking Head Screw Placement Of 2.7 / 3.5 Mm To Provide Adequate Fixation Of Metaphyseal Portion Of Tibia, And Size 4 To 14 Holes With Increment Of 2 Holes. , Anterolateral Distal Tibial Locking Plate 3.5 Mm. Anatomically Pre Shaped And Low Profile And Specific For Right And Left Side With Indication Of Side On Plate. Plate Should Have Head Holes To Accept 3.5 Mm Locking Head Or Standard Cortical Or 4 Mm Standard Cancellous Screw. Head Should Be Received Into The Plate. Size From 5 To 21 Holes With Increment Of 2 Holes , Cobra Head Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Cobra Head Locking Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Hook Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Hook Locking Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Proximal Humerus Locking Plate ( Philos Plate ) . Anatomically Pre-Countoured Plates, Should Have Precisely Fitting Sleeves For Precision Placement Ofscrews, Should Accept 3.5 Mm Locking Head Screws. The Screws Provided Should Be Available From 26 To 60 Mm Length. The Head Of The Plate Should Have Holes For Securing Tuberosities To The Plate With Sutures. Should Have Low Profile Of The Screws Heads To Prevent Tissue Irritation 3, 4, 5, 6, 7, 8, 9, 10, 12 Holes , ( A ) Anatomically Pre-Countoured Plates For Distal Medial Humerus For Anatomical Fit With Left & Right Version. Should Have Precisely Fitting Sleeves For Precision Placement Of Screws. Should Accept Self-Tapping Locking Head Screws. The Shaft Portions Of The Plate Should Have Combi Holes. Should Have Low Profile Of The Screws Heads To Prevent Tissue Irritation. 3, 5, 7, 9 & 14 Holes , ( B ) Dorso-Lateral Plates With & Without Lateral Support With Right & Left Versions. Anatomically Pre-Countoured Plates, The Shaft Portions Of The Plate Should Have Combi Holes. Should Have Low Profile Of The Screws Heads To Prevent Tissue Irritation.3, 5, 7, 9 & 14 Holes , Calcaneal Plate. , Calcaneal Locking Plates. , Anatomical Olecranon Locking Plate Of All Sizes. , Clavicle Locking Plate- Antero-Superior Type, Anterior Type , Clavicle Hook Plate. , Elise Plate / Contoured Plate For Distal End Radius. 3, 4, 5, 6, 7, 8, 9, 10 Holes , Locking Elise Plate / Contoured Locking Plate For Distal End Radius. 3, 4, 5, 6, 7, 8, 9, 10 Holes , Variable Angle Locking , H-Plate. 3, 4, 5, 6, 7, 8, 9, 10 Holes , Y- Plate. 3, 4, 5, 6, 7, 8, 9, 10 Holes , D.C.P. Small. 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , D.C.P. Narrow. 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , D.C.P. Broad. 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , L.C.D.C.P Small. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , L.C.D.C.P. Narrow. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , L.C.D.C.P. Broad. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , L.C.P Small. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , L.C.P. Narrow. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , L.C.P. Broad. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Semitubular Plates 4.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , Semitubular Plates 3.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , 1 / 3 Rd Tubular Plates 4.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , 1 / 3 Rd Tubular Plates 3.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , Quarter-Tubular Plates 2.7 Mm. 3, 4, 5, 6, 7, 8 Holes , Straight Mini Plates 2.0 Mm & 1.5 Mm With Screws. , Reconstuction Plates 3.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , Reconstuction Locking Plates 3.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , Reconstuction Plates 4.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , Reconstuction Locking Plates 4.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , Cortical Screw 4.5 Mm ( Tpi- 20 ) . 14, 16, 18 …60 Mm, In 2 Mm Increments. , Cortical Screw 3.5 Mm ( Tpi- 20 ) . 8, 10, 12 …60 Mm, In 2 Mm Increments. , Cortical Screw 2.7 Mm ( Tpi- 20 ) . 6, 8, 10 …30 Mm, In 2 Mm Increments. , Locking Cortical Screw 5.0 Mm. 14, 16, 18 …60 Mm, In 2 Mm Increments. , Locking Cortical Screw 3.5 Mm. 8, 10, 12 …60 Mm, In 2 Mm Increments. , Fully Threaded Cannulated Cancellous Screws 4Mm. 25, 30 ….115 Mm, In 5 Mm Increment , 16 Mm Threaded Cannulated Cancellous Screws 4 Mm. 25, 30 ….115 Mm, In 5 Mm Increment. , 32 Mm Threaded Cannulated Cancellous Screws 4 Mm 25, 30…….115 Mm, In 5 Mm Increment. , Fully Threaded Solid Cancellous Screws 4 Mm 25, 30…….115 Mm, In 5 Mm Increment , 16 Mm Threaded Solid Cancellous Screws 4 Mm 25, 30, …….115 Mm, In 5 Mm Increment , 32 Mm Threaded Solid Cancellous Screws 4 Mm 25, 30, …….115 Mm, In 5 Mm Increment , Fully Threaded Cannulated Cancellous Screws 6.5 Mm 25, 30, …….115 Mm, In 5 Mm Increment , 16 Mm Threaded Cannulated Cancellous Screws 6.5 Mm 25, 30, …….115 Mm, In 5 Mm Increment , 32 Mm Threaded Cannulated Cancellous Screws 6.5 Mm 25, 30, …….115 Mm, In 5 Mm Increment , Fully Threaded Solid Cancellous Screws 6.5 Mm ( 20 Tpi ) 25, 30, …….115 Mm, In 5 Mm Increment , 16 Mm Threaded Solid Cancellous Screws 6.5 Mm ( 20 Tpi ) 25, 30, …….115 Mm, In 5 Mm Increment , 32 Mm Threaded Solid Cancellous Screws 6.5 Mm ( 20 Tpi ) 25, 30, …….115 Mm, In 5 Mm Increment , Fully Threaded Locking Cannulated Cancellous Screws 6.5 Mm 25, 30, …….115 Mm, In 5 Mm Increment , 16 Mm Threaded Locking Cannulated Cancellous Screws 6.5 Mm 25, 30, …….115 Mm, In 5 Mm Increment , 32 Mm Threaded Locking Cannulated Cancellous Screws 6.5 Mm 25, 30, …….115 Mm, In 5 Mm Increment , Fully Threaded Locking Solid Cancellous Screws 6.5 Mm 25, 30, …….115 Mm, In 5 Mm Increment , 16 Mm Threaded Locking Solid Cancellous Screws 6.5 Mm 25, 30, …….115 Mm, In 5 Mm Increment , 32 Mm Threaded Locking Solid Cancellous Screws 6.5 Mm 25, 30, …….115 Mm, In 5 Mm Increment , Washer Round, 13 Mm, 10 Mm, 7.0 Mm, 4.5 Mm. , Spiked Washer, 13.5 Mm, 8.0 Mm, 3.2 Mm. , Malleolar Screw, 4.5 Mm 15, 20, 25, ………100 Mm , Herbert’S Screw , Interlocking Femur Nail ( As Per Ao Specifications ) With Compatible Locking Bolts Of Diameter 8, 9, 10, 11, 12 Mm With Lengths From 340 To 440Mm. , Interlocking Solid Femur Nail ( As Per Ao Specifications ) With Compatible Locking Bolts Of Diameter 8, 9, 10, 11, 12 Mm With Lengths From 340 To 440Mm. , Recon Nail ( Right & Left ) ( As Per Ao Specifications ) With Compatible Locking Bolts Of Diameter 8, 9, 10, 11, 12 Mm With Lengths From 340 To 440Mm. , Proximal Femur Nail ( P. F. N. ) ( As Per Ao Specifications ) With Compatible Locking Bolts Of Diameter 8, 9, 10, 11, 12 Mm With Lengths From 340 To 440Mm. , Trochanteric Entry Femur Nails With Compatible Locking Bolts Of Diameter 8, 9, 10, 11, 12 Mm With Lengths From 340 To 440Mm. , Supracondylar Nail ( As Per Ao Specifications ) With Compatible Locking Bolts Of Diameter 10, 11, 12 Mm With Lengths M150, 200, 250, 300 Mm . , Interlocking Tibia Nail ( As Per Ao Specifications ) With Compatible Locking Bolts Of Diameter 8, 9, 10, 11 Mm With Lengths From 280 To 380 Mm. , Interlocking Distal Tibia Nail ( As Per Ao Specifications ) With Compatible Locking Bolts Of Diameter 8, 9, 10, 11 Mm With Lengths From 280 To 380 Mm. , Interlocking High / Upper Bent Tibia Nail ( As Per Ao Specifications ) With Compatible Locking Bolts Of Diameter 8, 9, 10, 11 Mm With Lengths From 280 To 380 Mm. , Interlocking Solid Tibia Nail ( As Per Ao Specifications ) With Compatible Locking Bolts Of Diameter 8, 9, 10, 11 Mm With Lengths From 280 To 380 Mm. , Expert Tibial Nail ( As Per Ao Specifications ) With Compatible Locking Bolts Of Diameter 8, 9, 10, 11 Mm With Lengths From 280 To 380 Mm. , Interlocking Humerus Nail ( As Per Ao Specifications ) With Compatible Locking Bolts Of Diameter 6, 7, 8 Mm With Lengths From 200 To 300 Mm. , Interlocking Bolts2.9 Mm12 To 30 Mm , Interlocking Bolts3.9 Mm 14 To 48 Mm , Interlocking Bolts4.9 Mm 16 To 120 Mm , Proximal Bolt Recon ( As Per Ao Specifications ) Of Diameter 6.4Mm With Lengths From 60 To 110 Mm. , Proximal Bolt Recon Cannulated ( As Per Ao Specifications ) Of Diameter 6.4Mm With Lengths From 60 To 110 Mm. , Proximal Bolt P.F.N. Cannulated 6.4 Mm60 To 110 Mm , Proximal Bolt P.F.N. Cannulated8.0 Mm60 To 120 Mm , Kuntscher’S Nail Of 7, 8, 9, 10, 11, 12 Mm Diameter , V-Nail , Square Nail For Ulna Of2, 2.5, 3, 3.5 Mm Diameter , Square Nail For Radius Of2, 2.5, 3, 3.5 Mm Diameter , Rush Nail Of 2, 2.5, 3, 3.5 Mm Diameter , Ender’S Nail Of 2, 2.5, 3.0, 3.5, 4, 4.5 Mm Diameter. , Titanium Elastic Nailing System ( Tens ) Of All Sizes. , Non Fenestrated Bipolar Prosthesis Of Sizes 37, 39, …………….51, 53 Mm , Fenestrated Bipolar Prosthesisof Sizes 37, 39, …………….51, 53 Mm , Bipolar Prosthesis With Modular Stem And Head. , Thompson Endo-Prosthesis Of Sizes 37, 39, 41, 43, 45, 47, 49, 51, 53 Mm. , Long / Shortstem Austin Moore Prosthesis Of Sizes 37, 39, 41, 43, 45, 47, 49, 51, 53 Mm. , Bone Cement ( Price Tobe Quoted Separately For The Following 4 Items ) :- Cement Gun Should Be Provide By The Dealer As Loan Instruments Without Extra Charges During Total Hip Replacement Surgeries. Cost Of Disposable Nozzle To Be Provided Separately . , 1. High Viscosity Poly Methyl Meth-Acrylate 40Gms With Working Time Of 5-6 Min. , 2. Medium To Low Viscosity Poly Methyl Meth-Acrylate 40Gms. , 3. High Viscosity Poly Methyl Meth-Acrylate 40Gms With Working Time Of 5-6 Min With Gentamycin. , 4. Medium To Low Viscosity Poly Methyl Meth-Acrylate 40Gms With Gentamycin. , Cement Stopperof Size 7, 8, 9……To………….16Mm , Calcium Sulphate Bone Substitutes , Cemented Totalhip Replacement :-*Stem Should Be As Per Standard Charnley’S Design With Metal Of Sufficent Strength To Withstand Life-Time Use In The Patients. Different Sizes And Offsets To Be Quoted.*Cup Of Polyethylene High Density High Molecular Weight Highly Crosslinked With Anti-Oxidative Manufacturing & Storing Process ( To Increases The Shelf Life ) With Different Offsets. *Cup Sizes : - 38 To 60 Mm Outer Diameter. *Modularity For Neck Length And Head Sizes 22, 28, 32 And 36 Mm. *Acetabular Component Should Be Metal Backed As Well As All Poly. Metal Back Should Have Modularity To Use Polyethylene As Well As Ceramic. All Polyethylene Liner As Well As Cups Should Be Made Of Highly Cross-Linked Highmolecular Weight Polyethylene With Measures To Prevent Oxidation . The Metal Used For Stem Should Be Of High Tensile Strength And Fatigue Strength Like Cobalt-Chrome. , Uncemented T.H.R :-*The Stem Of The Femoral Component Should Have Double Taper Geometry With Plasma Hydroxy-Appetite Coating With At Least Thickness Of The Coating Of 100 To 200 Microns Or Porous Coated With Sufficient Pore Size And Thickness Of Porous Coating To Have Optimal Bony Ingrowth. The Stem Should Accept Metal ( Cobalt- Chrome ) As Well As Ceramic Head ( Alumina With Zirconia ) *Cup Of Polyethylene High Density High Molecular Weight Highly Crosslinked With Anti-Oxidative Manufacturing & Storing Process ( Toincreases The Shelf Life ) With Different Offsets. Preferably The Cup Should Have Longer Posterior Wall With Flange For Cement Pressurization. Metal Back Cup With Plasma Hydroxy-Appetite Coating With Design To Lock Into The Host Bone To Provide Primary Fixation With Provision For Screw Fixation. Should Accept Liners Made Up Of Highly Cross-Linked High Molecular Weight Poly-Ethylene & Delta Ceramic ( Alumina With Zirconia ) .*The Femoral Head Should Be Made Up Of Cobalt-Chrome Or Delta-Ceramic And Should Have Different Neck Length.*Metal Screws For Fixation Of Metal Cup.*The Prices Should Be Quoted Separately For Stems, Cups Liners Of Polyethylene And Ceramic As Per Specifications Mentioned Above And As Well As For Metal & Ceramic Heads Of Different Sizes As Per Specifications Quoted Above. , Revision T.H.R:-*Revision Stem, Modular Straight Cylindrical And Double Tapered, Porous & Hydroxy-Appetite Coated Of Different Lengths. The Diameter And Length Of The Stem Should Be Variable With A Provision To Address Curve Of The Femur With Long Stem. *Revision Cups To Be Provided With Large Diameter Of Upto 65 Mm With Augments For Bone Loss In The Form Of Cages And Metal Rings, As Well As, Wedges. All These To Be Quoted Separately. , Total Knee Replacement :- All Polyethylene & Metal Back. Mobile Bearing & Fixed Bearing Knees Highly Polished Tibial Tray To Prevent Back Wear In Fixed Bearing Knee. Pateller Component Should To Be Quoted Separately Cruciate-Retaining / Cruciate-Scarificing Designs. For Revision, Constraint Designs With Intramedullary Extension . Designs For Achieving High Flexion. All Components Should Be Separately Quoted. Note:- Company Should Be Us-Fda / Ce / Gmp Certified.. Should Provide A Technician Intraoperatively Wherever Applicable. Should Provide Suitable Size Cutting Saw With Drills ( Pneumatic / Electric ) , Wherever Applicable. Should Provide All The Complementary Instrumentation And Trials Given / Provided By The Manufacturing Company For The Application Of Implant During Operation. Catalogue / List Of These Instrumentation And Trials Should Be Included In Tender Quotations. Only Those Joint Designs To Be Sent Which Have Had A Proven Field Record Of Longevity As Substantiated By Published Literature, The Tenderer Should Provide The Required Documents , Regular Shoulder Prosthesis & Reverse Shoulder Prosthesis ( Prices To Be Quoted Separately ) Of Size 35 Mm, 39 Mm , Total Elbow Prosthesis, Regular And Custom Made. , Radial Head Prosthesis Of Following Sizes :-16 Mm X 4 Mm X 6 Mm, 18 Mm X 4 Mm X 6 Mm, 18 Mm X 5 Mm X 6 Mm, 20 Mm X 5 Mm X 8 Mm , Continuous Loop Endobutton One Size Titanium Buttonwith Multiple Pre-Measured Loop Sizes Of 15, 20, 25, 30, 35, 40Mm Lengths. Preloaded With Polyester Braid Suture ( #5 Leading Suture & #2 Flipping Suture ) , Low- Profile Cancellous Screws Titanium 6.5 Mm Of Sizes 25, 30, 35, 40 Mm. , Spiked And Suture Washers Of 14 And 18 Mm. , Tibial Post Fixation Screw Titanium Made Of Dia 6.5 Mm And 30 Mm Length , Shaver Blades ( Ss Alloy / Platinum Tip ) :-Single Cutting:Razor Sharp Toothed Inner Blade No Teeth On Outerwindow 4Mm, 4.5 Mm 5Mm 5.5Mmstraight And Angleddouble Cutting:The Narrow Gap Between Inner And Outer Cutting Surfaces 4Mm, 4.5 Mm 5Mm 5.5Mm Straight And Angled , Resector: 4Mm, 4.5 Mm 5Mm 5.5Mm Straight And Angled , Burr Barrel Burrs 4Mm, 4.5 Mm 5Mm 5.5Mm6 Flute And 12 Flute Round Burrs4mm, 4.5 Mm 5Mm 5.5Mm6 Flute And 12 Flute , Spiked Ligament Staple Titanium Made. , Cannulated Cross Pin Titanium Made. , Cannulated Interference Screws- Roundhead Titanium / Bio Absorbable. Standard 4.5Mm Hex For Easier Insertion And Removal In Diameters 8Mm, 9Mm, 10Mm And 11Mm In Lengths 20Mm, 25Mm, 30Mm And 35Mm. , Cannulated Interference Screws- Fully Threaded Titanium / Bio Absorbable In Diameters 8Mm, 9Mm, 10Mm And 11Mm , In Lengths 20Mm, 25Mm, 30Mm And 35Mm , Braided Composite Suture ( I.E. Bio Fiber / Fiber Wire ) Multi-Strand, Long Chain Ultra-High Molecular Weight Polyethylene ( Uhmwpe ) Core With A Braided Jacket Of Polyester And Uhmwpe. Tapered , Cutting , Reverse Cutting And Diamond End , 3 / 8 Circle And 1 / 2 Circle. White; White / Blue; White / Green Colours. Usp Size 2 / Ep Size 5. Length 38 Inches / 90 Cms. , Braided Polyester Suture ( I.E. Ethibond ) , 2-0 And 5-0 With 4 Strands Braided, Sterile, Surgical Suture Composed Of Poly ( Ethylene Terephthalate ) . Prepared From Fibers Of High Molecular Weight, Long-Chain, Linear Polyesters Having Recurrent Aromatic Rings As An Integral Component. Coated With Polybutilate Or Poly { Oxy-1, 4 Butanediyloxy ( 1, 6-Dioxo-1, 6 Hexanediyl ) , 5Mm Synthetic, Braided, Non-Absorbable Suture ( I.E. Mersilene Tape ) , Titanium Interference Screws For Acl Repair. Sizes 8 Mm, 9 Mm, 10 Mm, 11 Mm, 12 Mm. , Titanium Endo-Button. , Titanium Endo-Disc. , A.O. Open / Closed Clamps, 2.5, 3.5, 4.5 Mm. , Cylindrical / Universal Clamps, 2.5, 3.5, 4.5 Mm , Rod To Rod Clamp. , Transverse Clamp. , Cortical Schanz Pin 2.5, 3.0, 3.5, 4, 4.5 Mm. , Cancellous Schanz Pin 5, 6 Mm. , Tubular Rod. , Connecting Rod Of 4, 5, 8, 10, 11 Mm Diameter. 4”, 6”, 8”, 10”, 12”, 14”, 16”, 18”. , A.O. Type External Fixator R / U. , Finger Distractor. , Radius Ulna Distractor. , Rail Road Fixator For Femur / Tibia. , Illizarov’S Ring Fixator. Half Ring Of 80, 100, 120, 140, 160, 180, 200, 220, 240 Mm. , Italian Femoral Arches 900, 1200. 80, 100, 120, 140, 160, 180, 200, 220, 240 Mm. , Multiple Fixation Clamps. , Schanz Pin Fixation Bolts. , Oblique Supports. , Threaded Rods 8 Mm Diameter. 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450 Mm. , Telescopic Rods. 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 Mm. , Male & Female Post, 2, 3, 4, 5 Hole Set , Male & Female Hinges, 1 Hole Set. , Connection Plates, 5, 6, 7, 8 Holes. , Twisted Plates, 5, 6, 7, 8 Holes. , Illizarov’S Wires Bayonet Type. 1.5, 1.8, 2.0 Mm. , Illizarov’S Wires Olive Type. 1.5, 1.8, 2.0 Mm. , Connecting Bolt. , Connecting Nut 10 Mm. , Wire Fixation Bolts Cannulated. , Wire Fixation Bolts Slotted. , Jess External Fixator Set. , Pelvic C Clamp. , Nails For Pelvic C Clamp. , Steinman Pin Of 3, 3.5, 4, 4.5, 5 Mm. , Denham Pin Of 3, 3.5, 4, 4.5, 5 Mm. , Kirschner Wire Double Ended Trocar Tip / Threaded Tip. Diameter 1, 1.2, 1.5, 1.8 2, 2.5, 3 Mm. Length 6”, 9”, 12”. , S.S. Wire Reel Of16 To 28Gauze. , Knowel’S Pin. , A.M. Pin. , Gigli Saw Wire. , Titanium Pedicle Screw Connecting Rod Set ( Mri- Compatible ) . , Titanium Cage ( Mri- Compatible ) 10Mm, 13Mm, 16 Mm, 19 Mm. , Titanium Staple ( Mri- Compatible ) . , Titanium Transverse Connector ( Mri- Compatible ) . , Titanium Mono-Axial Screws ( Mri- Compatible ) 5.3 Mm30 Mm, 35 Mm, 40 Mm, 45 Mm. , 6.0 Mm 30 Mm, 35 Mm, 40 Mm, 45 Mm. , Titanium Poly- Axial Screws ( Mri- Compatible ) , 5.3 Mm 30 Mm, 35 Mm, 40 Mm, 45 Mm. , 6.0 Mm 30 Mm, 35 Mm, 40 Mm, 45 Mm. , Hartsheel Implants For Spine ( Mri- Compatible ) . , Cervical Plates ( Mri- Compatible ) . , Harrington Rod System ( Mri- Compatible ) . , Mono Axial Locking Screw 4.5 Mm, 5.5 Mm, 6.5 Mm Diameter 30-50 Mm With 5 Mm Of Increament. , Mono Axial Locking Screw 6.5 Mm Diameter ( Iliac Screw ) , 60 – 75 Mm With 5 Mm Of Increament , Cross Link ( Inter Connector ) 5 Mm , Cervical H-Plate Ordinary Hole 4 Hole, 20 – 35 Mm With 2.5 Mm Of Increament , Cervical H-Plate Ordinary Hole6 Hole, 35 – 55 Mm With 2.5 Mm Of Increament , Cervical H-Plate Ordinary Hole8 Hole, 47.5 – 65 Mm With 2.5 Mm Of Increament , Cervical Spine Locking Plate 5 Hole, 25, 29, 33 Mm , Cervical Spine Locking Plate 8 Hole, 37, 41, 45 Mm , Drummonds Wire Without Button , Drummonds Wire With Button , Sublaminar Wire 12” , Sublaminar Wire 18” , Disposable Pulse Lavage Tubings. , Titanium 1.5 Mm 20 Hole Continous , Titanium 1.5 Mm 2 Hole With Gap , Titanium 1.5 Mm 3 Hole With Gap , Titanium 1.5 Mm 4 Hole With Gap , Titanium 1.5 Mm 6 Hole With Gap , Titanium 1.5 Mm 8 Hole Continuous , Titanium 1.5 Mm L Plate Left , Titanium 1.5 Mm L Plate Right , Titanium 1.5 Mm Orbital Plate 4 Hole With Gap , Titanium 1.5 Mm Orbital Plate 6 Hole With Gap , Titanium 1.5 Mm T Plate , Titanium 1.5 Mm Xplate , Titanium 1.5 Mm Yplate , Titanium 2 Mm 16 Hole Continuous , Titanium 2Mm 2 Holewith Gap , Titanium 2Mm 3 Holewith Gap , Titanium 2Mm 4 Holewith Gap , Titanium 2Mm 4 Holecontinuous , Titanium 2Mm 6 Holewith Gap , Titanium 2Mm 6 Hole Continuous , Titanium 2Mm 8 Holecontinuous , Titanium 2Mm L Plate Left , Titanium 2Mm L Plate Right , Titanium 2Mm Orbital Plate 4 Hole With Gap , Titanium Leg Screw 14 Mm , Titanium Wiremesh 2”X2” , Titaniumwiremesh 4”X4” , Titanium Wire Mesh 6”X2” , Titanium Wire Mesh8”X2” , Titanium Rconstruction Plate With Condyle Left Long Ramus ( 24 Hole ) , Titanium Rconstruction Plate With Condyle Left Short Ramus ( 20 Hole ) , Titanium Rconstruction Plate With Condyle Rightlong Ramus ( 24 Hole ) , Titanium Rconstruction Plate With Condyle Right Short Ramus ( 20 Hole ) , Titanium Rconstruction Plate Withoutcondyle Left Long Ramus ( 24 Hole ) , Titanium Rconstruction Plate Withoutcondyleleft Short Ramus ( 20Hole , Titanium Rconstruction Plate Withoutcondyleright Long Ramus ( 24Hole , Titanium Rconstruction Plate Withoutcondyleright Short Ramus ( 20Hole , Titanium Screw 1.5 Mm X 10Mm , Titanium Screw 1.5 Mm X 12Mm , Titanium Screw 1.5 Mm X 4Mm , Titanium Screw 1.5 Mm X 6Mm , Titanium Screw 1.5 Mm X 8Mm , Titanium Screw2 Mm X 10Mm , Titanium Screw 2 Mm X 12Mm , Titanium Screw2 Mm X 14Mm , Titanium Screw 2 Mm X 4Mm , Titanium Screw 2Mm X 6Mm , Titanium Screw 2 Mm X 8Mm , Titanium Screw 2.5 Mm X 10Mm , Titanium Screw 2.5 Mm X 12Mm , Titanium Screw 2.5 Mm X 14Mm , Titanium Screw 2.5 Mm X 4Mm , Titanium Screw 2.5 Mm X 6Mm , Titanium Screw 2.5 Mm X 8Mm , Titanium 2 Mm Orbital Plate 6 Hole With Gap , Titanium 2Mm Tplate , Titanium 2Mm Xplate , Titanium 2Mm Y Plate , Titanium 2.5 Mm 16 Hole Continues , Titanium 2.5 Mm 2 Hole With Gap , Titanium 2.5 Mm 3 Hole With Gap , Titanium 2.5 Mm 4 Hole With Gap , Titanium 2.5 Mm 6 Hole With Gap , Titanium 2.5 Mm 8 Hole With Gap , Titanium 2.5 Mm L Plate Left , Titanium 2.5 Mm L Plate Right , Titanium 2.5 Mm Orbital Plate 4 Hole With Gap , Titanium 2.5 Mm Orbital Plate 6 Hole With Gap , Titanium Chin Plates 10 Mm , Titanium Chin Plates 8 Mm , Titanium Emergency Screw 1.7Mmx4 Mm , Titanium Emergency Screw 1.7Mmx6 Mm , Titanium Emergency Screw 1.7Mmx8 Mm , Titanium Emergency Screw 2.2 Mmx10 Mm , Titanium Emergency Screw 2.2 Mmx4 Mm , Titanium Emergency Screw 2.2 Mmx6 Mm , Titanium Emergency Screw 2.2 Mmx8 Mm , Titanium Emergency Screw 2.2 Mmx10 Mm , Titanium Emergency Screw 2.7 Mmx6 Mm , Titanium Emergency Screw 2.7 Mmx8 Mm , Titanium Intermaxillary Fixation Screws 2 Mm X 10 Mm , Titanium Intermaxillary Fixation Screws 2 Mm X 8 Mm , Titanium Lag Screws 12 Mm , Titaninium Implant Pleting System Along With Hand Piece , Micromotor, Function Box , Foot Control , Pleting System , Mendible Distractor System Complete , Complete Tempromendibulerjoint Replacement System Along With Templetes , Archbar

Key Value

Document Fees
INR 2000 /-
EMD
INR 50000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Supply of Implant
Sl. No. Item Description
1D.H.S. Plate Long/short Barrel (38/25 mm)with Round, D. C., combi Hole 1250, 1300, 1350, 1400 Angle; 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18 holes
2D.H.S Screw 22mm /16mm threading with Compression Screw (Top-Bolt). (36 mm) 50 to 115 mm, in 5mm increments
3Pediatric D.H.S. Set
4D.C.S Plate (950) with Round, D. C., combi Holes 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20, 22, 24 holes
5Angle Blade Plate (950) with Round, D. C., combi Holes, Blade size 50, 55, 60, 65, 70 & 75 mm and 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18 holes
6Trochanteric Stabilisation Plate to be used with DHS
7Distal Femur Locking Compression Plate (Right & Left) Anatomical pre-shaped & Contoured with self-tapping Locking Head Screws; with Round Locking Holes for metaphyseal portion of plate & Combiholes for shaft of plate.
8Medial & Lateral Proximal Tibial Buttress Plate (T- & L- shape)- as per AO specifications. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes
9Proximal Medial & Lateral Tibial Plate 3.5 mm(Right & Left) Anatomically pre shaped and low profile. Two different plate design for left and right side with indication on side of plate. Plate should have 2 mm holes forProximal Fixation with k-wire and sutures for meniscal repair. Holes should accept 3.5 mm locking head or 3.5 mm Standard Cortical Screws from 4 to 20holes with increment of 2 holes.
10Proximal Medial/ Lateral Tibial Locking Plate for 4.5 mm screws Anatomically pre shaped and low profile design, two different plate design for left and right with indication on plate. Round metaphyseal locking holes and combi holes in shaft portion for locking and standard screws. Different angulation in proximal part of the plate to avoid primary and secondary loss of reduction. Should be compatible for less invasive technique Holes should accept 5 mm locking head or 6.5 mm standard cancellousl screwsfrom 5 to 13holes
11Hockey Plate For Tibia (Right & Left) 5, 7, 9, 11, 13, 15, 17 Holes
12Contoured Medial/ Antero-lateral Plate for Lower end Tibia 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes
13Distal Medial Tibial Locking Plates 2.7/ 3.5 mm. Anatomically pre-shaped and low profile and specific for right and left side with Indication of side on plate, compatible with less invasive fixation. Rounded edgesscrew heads should be received into Distal section of plate to allow multiple locking head screw placement of 2.7/ 3.5 mm to provide adequate fixation of metaphyseal portion of tibia, and size 4 to 14 holes with increment of 2 holes.
14Anterolateral Distal Tibial Locking Plate 3.5 mm. Anatomically pre shaped and low profile and specific for right and left side with indication of side on plate. Plate should have head holes to accept 3.5 mm Locking head or standard cortical or 4 mm standard cancellous screw. Head should be received into the plate. Size from 5 to 21 holes with increment of 2 holes
15Cobra Head Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes
16Cobra Head Locking Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes
17Hook Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes
18Hook Locking Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes
19Proximal Humerus Locking Plate (PHILOS Plate). Anatomically pre-countoured plates, Should have precisely fitting sleeves for precision placement ofscrews, Should accept 3.5 mm Locking Head Screws. The Screws provided should be available from 26 to 60 mm length. The head of the plate should have holes for securing tuberosities to the plate with sutures. Should have low profile of the screws heads to prevent tissue irritation 3, 4, 5, 6, 7, 8, 9, 10, 12 Holes
20(A) Anatomically pre-countoured plates for Distal Medial Humerus for anatomical fit with left & right version. Should have precisely fitting sleeves for precision placement of screws. Should accept self-tapping Locking Head Screws. The shaft portions of the plate should have Combi holes. Should have low profile of the screws heads to prevent tissue irritation. 3, 5, 7, 9 & 14 Holes
21(B) Dorso-lateral Plates with & without Lateral support with right & left versions. Anatomically pre-countoured plates, The shaft portions of the plate should have Combi holes. Should have low profile of the screws heads to prevent tissue irritation.3, 5, 7, 9 & 14 Holes
22Calcaneal Plate.
23Calcaneal Locking Plates.
24Anatomical Olecranon locking plate of all sizes.
25Clavicle Locking Plate- Antero-superior type, Anterior type
26Clavicle Hook Plate.
27Elise Plate/ Contoured Plate for Distal End Radius. 3, 4, 5, 6, 7, 8, 9, 10 Holes
28Locking Elise Plate/ Contoured Locking Plate for Distal End Radius. 3, 4, 5, 6, 7, 8, 9, 10 Holes
29Variable angle Locking
30H-Plate. 3, 4, 5, 6, 7, 8, 9, 10 Holes
31Y- Plate. 3, 4, 5, 6, 7, 8, 9, 10 Holes
32D.C.P. Small. 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes
33D.C.P. Narrow. 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes
34D.C.P. Broad. 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes
35L.C.D.C.P Small. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes
36L.C.D.C.P. Narrow. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes
37L.C.D.C.P. Broad. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes
38L.C.P Small. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes
39L.C.P. Narrow. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes
40L.C.P. Broad. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes
41Semitubular Plates 4.5mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes
42Semitubular Plates 3.5mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes
431/3 rd Tubular Plates 4.5mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes
441/3 rd Tubular Plates 3.5mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes
45Quarter-Tubular Plates 2.7 mm. 3, 4, 5, 6, 7, 8 Holes
46Straight Mini Plates 2.0 mm & 1.5 mm with screws.
47Reconstuction Plates 3.5mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes
48Reconstuction Locking Plates 3.5mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes
49Reconstuction Plates 4.5mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes
50Reconstuction Locking Plates 4.5mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes
51Cortical Screw 4.5 mm (TPI- 20). 14, 16, 18 …60 mm, in 2 mm increments.
52Cortical Screw 3.5 mm (TPI- 20). 8, 10, 12 …60 mm, in 2 mm increments.
53Cortical Screw 2.7 mm (TPI- 20). 6, 8, 10 …30 mm, in 2 mm increments.
54Locking Cortical Screw 5.0 mm. 14, 16, 18 …60 mm, in 2 mm increments.
55Locking Cortical Screw 3.5 mm. 8, 10, 12 …60 mm, in 2 mm increments.
56Fully threaded Cannulated Cancellous Screws 4mm. 25, 30 ….115 mm, in 5 mm increment
5716 mm threaded Cannulated Cancellous Screws 4 mm. 25, 30 ….115 mm, in 5 mm increment.
5832 mm threaded Cannulated Cancellous screws 4 mm 25, 30…….115 mm, in 5 mm increment.
59Fully threaded Solid Cancellous Screws 4 mm 25, 30…….115 mm, in 5 mm increment
6016 mm threaded Solid Cancellous Screws 4 mm 25, 30,…….115 mm, in 5 mm increment
6132 mm threaded Solid Cancellous screws 4 mm 25, 30,…….115 mm, in 5 mm increment
62Fully threaded Cannulated Cancellous Screws 6.5 mm 25, 30,…….115 mm, in 5 mm increment
6316 mm threaded Cannulated Cancellous Screws 6.5 mm 25, 30,…….115 mm, in 5 mm increment
6432 mm threaded Cannulated Cancellous screws 6.5 mm 25, 30,…….115 mm, in 5 mm increment
65Fully threaded Solid Cancellous Screws 6.5 mm (20 TPI) 25, 30,…….115 mm, in 5 mm increment
6616 mm threaded Solid Cancellous Screws 6.5 mm (20 TPI) 25, 30,…….115 mm, in 5 mm increment
6732 mm threaded Solid Cancellous screws 6.5 mm (20 TPI) 25, 30,…….115 mm, in 5 mm increment
68Fully threaded Locking Cannulated Cancellous Screws 6.5 mm 25, 30,…….115 mm, in 5 mm increment
6916 mm threaded Locking Cannulated Cancellous Screws 6.5 mm 25, 30,…….115 mm, in 5 mm increment
7032 mm threaded Locking Cannulated Cancellous screws 6.5 mm 25, 30,…….115 mm, in 5 mm increment
71Fully threaded Locking Solid Cancellous Screws 6.5 mm 25, 30,…….115 mm, in 5 mm increment
7216 mm threaded Locking Solid Cancellous Screws 6.5 mm 25, 30,…….115 mm, in 5 mm increment
7332 mm threaded Locking Solid Cancellous screws 6.5 mm 25, 30,…….115 mm, in 5 mm increment
74Washer Round, 13 mm, 10 mm, 7.0 mm, 4.5 mm.
75Spiked Washer, 13.5 mm, 8.0 mm, 3.2 mm.
76Malleolar Screw,4.5 mm 15, 20, 25,………100 mm
77Herbert’s screw
78Interlocking Femur Nail (As per AO specifications) with Compatible Locking Bolts of Diameter 8,9,10,11,12 mm with lengths from 340 to 440mm.
79Interlocking Solid Femur Nail (As per AO specifications) with Compatible Locking Bolts of Diameter 8,9,10,11,12 mm with lengths from 340 to 440mm.
80Recon Nail (Right & Left) (As per AO specifications) with Compatible Locking Bolts of Diameter 8,9,10,11,12 mm with lengths from 340 to 440mm.
81Proximal Femur Nail (P. F. N.) (As per AO specifications) with Compatible Locking Bolts of Diameter 8,9,10,11,12 mm with lengths from 340 to 440mm.
82Trochanteric Entry Femur Nails with Compatible Locking Bolts of Diameter 8,9,10,11,12 mm with lengths from 340 to 440mm.
83Supracondylar Nail (As per AO specifications) with Compatible Locking Bolts of Diameter 10,11,12 mm with lengths m150,200,250,300 mm .
84Interlocking Tibia Nail (As per AO specifications) with Compatible Locking Bolts of Diameter 8,9,10,11 mm with lengths from 280 to 380 mm.
85Interlocking Distal Tibia Nail (As per AO specifications) with Compatible Locking Bolts of Diameter 8,9,10,11 mm with lengths from 280 to 380 mm.
86Interlocking High/Upper Bent Tibia Nail (As per AO specifications) with Compatible Locking Bolts of Diameter 8,9,10,11 mm with lengths from 280 to 380 mm.
87Interlocking Solid Tibia Nail (As per AO specifications) with Compatible Locking Bolts of Diameter 8,9,10,11 mm with lengths from 280 to 380 mm.
88Expert Tibial Nail (As per AO specifications) with Compatible Locking Bolts of Diameter 8,9,10,11 mm with lengths from 280 to 380 mm.
89Interlocking Humerus Nail (As per AO specifications) with Compatible Locking Bolts of Diameter 6,7, 8 mm with lengths from 200 to 300 mm.
90Interlocking Bolts2.9 mm12 to 30 mm
91Interlocking Bolts3.9 mm 14 to 48 mm
92Interlocking Bolts4.9 mm 16 to 120 mm
93Proximal Bolt RECON (As per AO specifications) of Diameter 6.4mm with lengths from 60 to 110 mm.
94Proximal Bolt RECON Cannulated (As per AO specifications) of Diameter 6.4mm with lengths from 60 to 110 mm.
95Proximal Bolt P.F.N. Cannulated 6.4 mm60 to 110 mm
96Proximal Bolt P.F.N. Cannulated8.0 mm60 to 120 mm
97Kuntscher’s Nail of 7, 8, 9, 10, 11, 12 mm diameter
98V-Nail
99Square Nail for Ulna of2, 2.5, 3, 3.5 mm diameter
100Square Nail for Radius of2, 2.5, 3, 3.5 mm diameter
101Rush Nail of 2, 2.5, 3, 3.5 mm diameter
102Ender’s Nail of 2,2.5,3.0,3.5, 4, 4.5 mm diameter.
103Titanium Elastic Nailing System (TENS) of all sizes.
104Non fenestrated bipolar prosthesis of sizes 37, 39,…………….51, 53 mm
105Fenestrated bipolar prosthesisof sizes 37, 39,…………….51, 53 mm
106Bipolar Prosthesis with modular stem and head.
107Thompson Endo-Prosthesis of sizes 37, 39, 41, 43, 45, 47, 49, 51, 53 mm.
108Long/shortstem Austin moore prosthesis of sizes 37, 39, 41, 43, 45, 47, 49, 51, 53 mm.
109Bone cement (Price tobe quoted separately for the following 4 items) :- Cement Gun should be provide by the dealer as loan instruments without extra charges during Total Hip Replacement surgeries. Cost of Disposable Nozzle to be provided separately .
1101.     High viscosity Poly Methyl Meth-Acrylate 40gms with working time of 5-6 min.
1112.     Medium to low viscosity Poly Methyl Meth-Acrylate 40gms.
1123.     High viscosity Poly Methyl Meth-Acrylate 40gms with working time of 5-6 min with Gentamycin.
1134.     Medium to low viscosity Poly Methyl Meth-Acrylate 40gms with Gentamycin.
114Cement stopperof size 7,8,9……to………….16mm
115Calcium sulphate bone substitutes
116Cemented TotalHip Replacement :-*Stem should be as per Standard Charnley’s Design with metal of sufficent strength to withstand life-time use in the patients. Different sizes and offsets to be quoted.*Cup of Polyethylene High Density High Molecular Weight Highly Crosslinked with anti-oxidative manufacturing & storing process (to increases the shelf life) with different offsets. *Cup Sizes : - 38 to 60 mm Outer Diameter. *Modularity for neck length and head sizes 22, 28, 32 and 36 mm. *Acetabular component should be metal backed as well as all poly. Metal back should have modularity to use polyethylene as well as Ceramic. All Polyethylene liner as well as cups should be made of highly Cross-linked HighMolecular Weight polyethylene with measures to prevent Oxidation . The metal used for stem should be of high tensile strength and fatigue strength like Cobalt-Chrome.
117Uncemented T.H.R :-*The stem of the Femoral Component should have Double Taper Geometry with Plasma Hydroxy-Appetite coating with at least thickness of the coating of 100 to 200 microns or Porous coated with sufficient pore size and thickness of porous coating to have optimal bony ingrowth. The stem should accept metal (Cobalt- Chrome) as well as Ceramic Head (Alumina with Zirconia)*Cup of Polyethylene High Density High Molecular Weight Highly Crosslinked with anti-oxidative manufacturing & storing process (toincreases the shelf life) with different offsets. Preferably the cup should have longer posterior wall with flange for cement pressurization. Metal Back cup with Plasma Hydroxy-Appetite coating with design to lock into the host bone to provide primary fixation with provision for screw fixation. Should accept liners made up of Highly Cross-Linked High Molecular Weight Poly-Ethylene & Delta Ceramic (Alumina with Zirconia).*The Femoral Head should be made up of Cobalt-Chrome or Delta-Ceramic and should have different Neck length.*Metal screws for fixation of metal cup.*The Prices should be quoted separately for stems, cups liners of polyethylene and ceramic as per specifications mentioned above and as well as for metal & ceramic heads of different sizes as per specifications quoted above.
118Revision T.H.R:-*Revision stem, Modular Straight Cylindrical And Double Tapered, Porous & Hydroxy-Appetite coated of different lengths. The diameter and length of the stem should be variable with a provision to address curve of the femur with long stem. *Revision cups to be provided with large diameter of upto 65 mm with augments for bone loss in the form of cages and metal rings, as well as, wedges. All these to be quoted separately.
119Total Knee Replacement :- All polyethylene & metal back. Mobile bearing & fixed bearing Knees Highly polished tibial tray to prevent back wear in Fixed bearing knee. Pateller component should to be quoted separately Cruciate-Retaining/ Cruciate-Scarificing Designs. For revision, Constraint designs with Intramedullary extension . Designs for achieving high flexion. All components should be separately quoted. Note:- Company should be US-FDA /CE/ GMP certified.. Should provide a technician intraoperatively wherever applicable. Should provide suitable size cutting saw with drills (pneumatic/electric) , wherever applicable.\ Should provide all the complementary instrumentation and trials given/provided by the manufacturing company for the application of implant during operation. Catalogue/ list of these instrumentation and trials should be included in tender quotations. Only those Joint designs to be sent which have had a proven field record of longevity as substantiated by published literature, the tenderer should provide the required documents
120Regular Shoulder prosthesis & Reverse Shoulder Prosthesis (Prices to be quoted separately) of size 35 mm, 39 mm
121Total elbow prosthesis, Regular and custom made.
122Radial head prosthesis of following sizes :-16 mm x 4 mm x 6 mm, 18 mm x 4 mm x 6 mm, 18 mm x 5 mm x 6 mm, 20 mm x 5 mm x 8 mm
123Continuous loop endobutton One size titanium buttonwith multiple pre-measured loop sizes of 15, 20, 25, 30, 35, 40mm lengths. Preloaded with polyester braid suture (#5 leading suture & #2 flipping suture)
124Low- Profile Cancellous Screws Titanium 6.5 mm of sizes 25, 30, 35, 40 mm.
125Spiked and suture Washers of 14 and 18 mm.
126Tibial Post Fixation Screw Titanium made of Dia 6.5 mm and 30 mm length
127Shaver Blades (SS alloy / platinum tip):-Single cutting:Razor sharp toothed inner blade No teeth on outerwindow 4mm, 4.5 mm 5mm 5.5mmStraight and angledDouble Cutting:The narrow gap between inner and outer cutting surfaces 4mm, 4.5 mm 5mm 5.5mm Straight and angled
128Resector: 4mm, 4.5 mm 5mm 5.5mm Straight and angled
129Burr Barrel burrs 4mm, 4.5 mm 5mm 5.5mm6 flute and 12 flute Round Burrs4mm, 4.5 mm 5mm 5.5mm6 flute and 12 flute
130Spiked Ligament Staple Titanium made.
131Cannulated Cross Pin Titanium made.
132Cannulated Interference Screws- Roundhead  Titanium/Bio absorbable. Standard 4.5mm hex for easier insertion and removal in diameters 8mm, 9mm, 10mm and 11mm in lengths 20mm, 25mm, 30mm and 35mm.
133Cannulated Interference Screws- Fully Threaded Titanium/Bio absorbable in diameters 8mm, 9mm, 10mm and 11mm , in lengths 20mm, 25mm, 30mm and 35mm
134Braided Composite suture (i.e. Bio Fiber/fiber wire) multi-strand,long chain ultra-high molecular weight polyethylene (UHMWPE) core with a braided jacket of polyester and UHMWPE. Tapered ,cutting ,reverse cutting and diamond end ,3/8 circle and 1/2 circle. white; white/blue; white/green colours. USP size 2/ EP size 5. length 38 inches/90 cms.
135Braided polyester suture( i.e. Ethibond ), 2-0 and 5-0 with 4 strands braided, sterile, surgical suture composed of Poly (ethylene terephthalate). prepared from fibers of high molecular weight, long-chain, linear polyesters having recurrent aromatic rings as an integral component. coated with polybutilate or poly {oxy-1, 4 butanediyloxy (1, 6-dioxo-1, 6 hexanediyl)
1365mm  synthetic, braided, non-absorbable suture (i.e. Mersilene tape)
137Titanium Interference screws for ACL repair. Sizes 8 mm, 9 mm, 10 mm, 11 mm, 12 mm.
138Titanium Endo-Button.
139Titanium Endo-Disc.
140A.O. Open / closed Clamps, 2.5, 3.5, 4.5 mm.
141Cylindrical/ Universal Clamps, 2.5, 3.5, 4.5 mm
142Rod to Rod Clamp.
143Transverse Clamp.
144Cortical Schanz Pin 2.5,3.0,3.5,4,4.5 mm.
145Cancellous Schanz Pin 5,6 mm.
146Tubular Rod.
147Connecting Rod of 4, 5, 8, 10, 11 mm diameter. 4”, 6”, 8”, 10”, 12”, 14”, 16”, 18”.
148A.O. Type External Fixator R/U.
149Finger Distractor.
150Radius Ulna Distractor.
151Rail Road Fixator for Femur / Tibia.
152Illizarov’s Ring Fixator. Half Ring of 80, 100, 120, 140, 160, 180, 200, 220, 240 mm.
153Italian Femoral Arches 900, 1200. 80, 100, 120, 140, 160, 180, 200, 220, 240 mm.
154Multiple Fixation Clamps.
155Schanz Pin Fixation Bolts.
156Oblique Supports.
157Threaded Rods 8 mm diameter. 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450 mm.
158Telescopic Rods. 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 mm.
159Male & Female Post, 2, 3, 4, 5 hole set
160Male & Female Hinges, 1 hole set.
161Connection Plates, 5, 6, 7, 8 holes.
162Twisted Plates, 5, 6, 7, 8 holes.
163Illizarov’s Wires Bayonet Type. 1.5, 1.8, 2.0 mm.
164Illizarov’s Wires Olive Type. 1.5, 1.8, 2.0 mm.
165Connecting Bolt.
166Connecting Nut 10 mm.
167Wire Fixation Bolts Cannulated.
168Wire Fixation Bolts Slotted.
169JESS External fixator set.
170Pelvic C Clamp.
171Nails for Pelvic C Clamp.
172Steinman Pin of 3, 3.5, 4, 4.5, 5 mm.
173Denham Pin of 3, 3.5, 4, 4.5, 5 mm.
174Kirschner Wire double ended Trocar Tip/ Threaded Tip. Diameter 1,1.2, 1.5,1.8 2, 2.5, 3 mm. Length 6”, 9”, 12”.
175S.S. Wire Reel of16 to 28Gauze.
176Knowel’s Pin.
177A.M. Pin.
178Gigli Saw Wire.
179Titanium Pedicle Screw connecting Rod Set (MRI- compatible).
180Titanium Cage (MRI- compatible) 10mm, 13mm, 16 mm, 19 mm.
181Titanium Staple (MRI- compatible).
182Titanium Transverse Connector (MRI- compatible).
183Titanium Mono-Axial Screws (MRI- compatible) 5.3 mm30 mm, 35 mm, 40 mm, 45 mm.
1846.0 mm 30 mm, 35 mm, 40 mm, 45 mm.
185Titanium Poly- Axial Screws (MRI- compatible)
1865.3 mm 30 mm, 35 mm, 40 mm, 45 mm.
1876.0 mm 30 mm, 35 mm, 40 mm, 45 mm.
188Hartsheel Implants for Spine (MRI- compatible).
189Cervical Plates (MRI- compatible).
190Harrington Rod System (MRI- compatible).
191Mono axial locking screw 4.5 mm, 5.5 mm, 6.5 mm diameter 30-50 mm with 5 mm of increament.
192Mono axial locking screw 6.5 mm diameter (Iliac screw) , 60 – 75 mm with 5 mm of increament
193Cross link (Inter connector) 5 mm
194Cervical H-plate ordinary hole 4 hole, 20 – 35 mm with 2.5 mm of increament
195Cervical H-plate ordinary hole6 hole, 35 – 55 mm with 2.5 mm of increament
196Cervical H-plate ordinary hole8 hole, 47.5 – 65 mm with 2.5 mm of increament
197Cervical spine locking plate 5 hole, 25, 29, 33 mm
198Cervical spine locking plate 8 hole, 37, 41, 45 mm
199Drummonds wire without button
200Drummonds wire with button
201Sublaminar wire 12”
202Sublaminar wire 18”
203Disposable Pulse Lavage Tubings.
204Titanium 1.5 mm 20 Hole continous
205Titanium 1.5 mm 2 hole with gap
206Titanium 1.5 mm 3 hole with gap
207Titanium 1.5 mm 4 hole with gap
208Titanium 1.5 mm 6 hole with gap
209Titanium 1.5 mm 8 hole continuous
210Titanium 1.5 mm L Plate Left
211Titanium 1.5 mm L Plate Right
212Titanium 1.5 mm Orbital plate 4 hole with gap
213Titanium 1.5 mm Orbital plate 6 hole with gap
214Titanium 1.5 mm T Plate
215Titanium 1.5 mm XPlate
216Titanium 1.5 mm YPlate
217Titanium 2 mm 16 hole continuous
218Titanium 2mm 2 holewith gap
219Titanium 2mm 3 holewith gap
220Titanium 2mm 4 holewith gap
221Titanium 2mm 4 holecontinuous
222Titanium 2mm 6 holewith gap
223Titanium 2mm 6 hole continuous
224Titanium 2mm 8 holecontinuous
225Titanium 2mm L plate left
226Titanium 2mm L plate right
227Titanium 2mm orbital plate 4 hole with gap
228Titanium leg screw 14 mm
229Titanium wiremesh 2”x2”
230Titaniumwiremesh 4”x4”
231Titanium wire mesh 6”x2”
232Titanium wire mesh8”x2”
233Titanium Rconstruction plate with condyle left long ramus (24 hole )
234Titanium Rconstruction plate with condyle left short ramus (20 hole )
235Titanium Rconstruction plate with condyle rightlong ramus (24 hole )
236Titanium Rconstruction plate with condyle right short ramus (20 hole )
237Titanium Rconstruction plate withoutcondyle left long ramus(24 hole )
238Titanium Rconstruction plate withoutcondyleleft short ramus(20hole
239Titanium Rconstruction plate withoutcondyleright long ramus(24hole
240Titanium Rconstruction plate withoutcondyleright short ramus (20hole
241Titanium Screw 1.5 mm x 10mm
242Titanium Screw 1.5 mm x 12mm
243Titanium Screw 1.5 mm x 4mm
244Titanium Screw 1.5 mm x 6mm
245Titanium Screw 1.5 mm x 8mm
246Titanium Screw2 mm x 10mm
247Titanium Screw 2 mm x 12mm
248Titanium Screw2 mm x 14mm
249Titanium Screw 2 mm x 4mm
250Titanium Screw 2mm x 6mm
251Titanium Screw 2 mm x 8mm
252Titanium Screw 2.5 mm x 10mm
253Titanium Screw 2.5 mm x 12mm
254Titanium Screw 2.5 mm x 14mm
255Titanium Screw 2.5 mm x 4mm
256Titanium Screw 2.5 mm x 6mm
257Titanium Screw 2.5 mm x 8mm
258Titanium 2 mm orbital plate 6 hole with gap
259Titanium 2mm Tplate
260Titanium 2mm xplate
261Titanium 2mm Y plate
262Titanium 2.5 mm 16 hole continues
263Titanium 2.5 mm 2 hole with gap
264Titanium 2.5 mm 3 hole with gap
265Titanium 2.5 mm 4 hole with gap
266Titanium 2.5 mm 6 hole with gap
267Titanium 2.5 mm 8 hole with gap
268Titanium 2.5 mm L plate left
269Titanium 2.5 mm L plate Right
270Titanium 2.5 mm orbital plate 4 Hole with gap
271Titanium 2.5 mm orbital plate 6 Hole with gap
272Titanium chin plates 10 mm
273Titanium chin plates 8 mm
274Titanium emergency screw 1.7mmX4 mm
275Titanium emergency screw 1.7mmX6 mm
276Titanium emergency screw 1.7mmX8 mm
277Titanium emergency screw 2.2 mmX10 mm
278Titanium emergency screw 2.2 mmX4 mm
279Titanium emergency screw 2.2 mmX6 mm
280Titanium emergency screw 2.2 mmX8 mm
281Titanium emergency screw 2.2 mmX10 mm
282Titanium emergency screw 2.7 mmX6 mm
283Titanium emergency screw 2.7 mmX8 mm
284Titanium intermaxillary fixation screws 2 mm X 10 mm
285Titanium intermaxillary fixation screws 2 mm X 8 mm
286Titanium Lag Screws 12 mm
287Titaninium implant Pleting system along with hand piece , micromotor,function box ,foot control ,pleting system
288Mendible distractor system complete
289Complete tempromendibulerjoint replacement system along with templetes
290Archbar
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail