| 1 | Supply Fitting, fixing & commissioning of following dia bulk eletromagnetic water meterwith the development of the application for monitoring and reporting(in .xlsx format & GUI) the LIVE data of total flow and pressure in each area of the water distribution channel and integrate the application with an existing PHEO application. (Application: The PHEO is having one existing application in the platform of LINUX, PHP, MySQL, JAVA script, HTML, CSH, AJAX, J-Query). All complete as per direction of Engineer in charge. |
| 2 | 150mm dia Full bore type Electro Magnetic Water Flow meter |
| 3 | 200mm dia Full bore type Electro Magnetic Water Flow meter |
| 4 | 250mm dia Full bore type Electro Magnetic Water Flow meter |
| 5 | Supplying, Fitting,Commissioning,Fixing double / single chamber DI PN 16 control valve,hydraulically operated, single diaphragm actuated, globe pattern The valve shall consist of three major components; the body with the seat installed; the cover with the bearing installed and the diaphragm assembly. The diaphragm assembly shall be the only moving part and shall form a sealed chamber in the upper portion of the valve, separating the operating pressure from line pressure. Packing glands, stuffing boxesand there shall be no piston operating the main valve or pilot controls. No fabrication or welding shall be used in the manufacturing process.The control will be achieved by operating of 2 number Solenoid Valves mounted on the main Valve,electronic timer controller,Timer,integral oriface plate assembly,differential control,reverse flow control,restriction orifice.The Connecting tubing on the Main Valve will be SS with SS fitting from reputedmake. The valve shall be working up to 3.0 kg/cm2 operating pressure Body A216 WCBintegrated with PLC pannel for operation (local/remort and web enabled with command and control) make CLA/SINGER/ VAG to control water supplyincluding the cost of valve cutting the pipeline & making good to the damagesincludingcost ofall labours, T&P etc. all completeas per the direction of Engineer-in-charge. |
| 6 | 150mm diaPN16 Flow Control Valve with 2 nos solenoid |
| 7 | 200mm diaPN16 Flow Control Valve with 2 nos solenoid |
| 8 | 250mm diaPN16 Flow Control Valve with 2 nos solenoid |
| 9 | Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately |
| 10 | Supplying all materials, labour, tools & plants for cutting ofmettaledroad for laying of pipeline including conveyance of all material at work, etc. all complete as per specification and direction of the EIC |
| 11 | Supplying all labour, T&P and earth work in excavation in all kinds of soil in pipe trenchs etc including dressing and levelling the bed and depositing the soil within 50M initial lead and 1.5M initial lift, as per the direction of the Engineer-in-charge. |
| 12 | Supplying all materials, labour, and T&P for providing mechanical joints to flange socket as per relevant IS with suitable flanged joints and fitting & fixing of following in pipeas per specifications including testing with cost of all jointing materials, transportation to site etc. all completeas per the specifications and directions of Engineer-in-charge. |
| 13 | 150mm dia MJ Socket |
| 14 | 200mm dia MJ Socket |
| 15 | 250mm dia MJ Socket |
| 16 | Supplying all labour and T&P for providing and laying MS pipe and specials confirming to IS 3589/99 of quality grade FE 410/ GI Pipe (Medium ) confirming to specificationof following nominal dia and including transportation of pipes and fitting to site etc all complete as per the direction of E.I.C. |
| 17 | 168.30mm ODM.S.Pipe 6.3mm thick |
| 18 | 219.10mm ODM.S.Pipe 6.3mm thick |
| 19 | 273.0mm ODM.S.Pipe 6.30mm thick |
| 20 | Supplying M.S.flange of following thick suitable for following dia of M.S./C.I pipes specials,valves with wastage including cost of materials, labour, T & P etc all complete. |
| 21 | 150mm dia M.S. Flange.(12mm thick) |
| 22 | 200mm dia M.S. Flange.(12mm thick) |
| 23 | 250mm dia M.S. Flange.(12mm thick) |
| 24 | Supplying all labour and T&P for cutting of following dia MS pipe of following thick in treanches by gas cutter set of pocket etc all complete |
| 25 | Providing joints by welding with two welding beads/pass, conforming to IS:816-1998 (Single 60° Butt weld) to MS pipes upto 8mm thickand fittings at site by using welding generator including testing of joints, as per specification complete |
| 26 | Supplying all materials, labour and T&P for making flanged joints for C.I. pipes and specials of the following diameter including testing of joints as per specification and direction of E.I.C. |
| 27 | 150mm dia |
| 28 | 200mm dia - |
| 29 | 350mm dia - |
| 30 | Cutting of C.I /DI pipe by eletric arc welding,at site including cost of materials,labour,T & P etc all complete |
| 31 | Supplying all materials, labour T&P for construction of RCCValve chamber of following internal sizes having earth work in excavation in all kinds of soil, 150mm sand filling ,150mm PCC (1:3:6), 200mm thick base, wall & cover slab with RCC 1:1½:3, fixing factory made precast SD20 Frame & cover slab, foot step iron etc all complete. |
| 32 | (0.90m.x0.90mx 1.20mtr )with SFRCcover 600mm dia |
| 33 | Supply of Pressure transducer to be installed at 250 mm dia delivery main with following technical specification i.e Range up to 10 Kg/cm2 , Type -Sensor ,power Supply-24 DC , Out put-4 to 2 mA , Make -E & H/ABB/VEGA with SS 316 grade sensor niddle valve with bypass tube |
| 34 | Supply Fitting, fixing & commissioning of following diaPilot Altitude valvefor purpose to close valve at a maximum water level of ESR& to open to refill the ESR when the water level in the ESR at lowers.Altitude Control Valve should be worked at minimumpressure1kg/cm2 .An altitude control valve controls the level of a tank. The altitude valve will remain open while the tank is not full and it will close when the tanks reaches its maximum level. The opening and closing of the valve will work without external power source (electric, pneumatic, or man power), it will workautomatically,The body, Spool,& cover will be DI ASTM A-536 standard,Spring,steam, Jam Nut ,Cover bolt & cover washer should be SS , DI /SS Diaphragm plate,Nytril/Nylon diaphragm ,Bronze cover bushing,Seat plate & ring .Make - (VAG/SINGER/CLA/BURMAD) |
| 35 | 250mm dia - |
| 36 | Cutting of cement concrete road for repair/laying of water supply line pipe removal of debries by Tractor-trolley including,transportation,all labours, T&P etc. all complete as per the direction of Engineer-in-charge. |
| 37 | Cutting of Asphalt road for repair/laying of water supplypipe line removal of debries by Tractor-trolley including,transportation,all labours, T&P etc. all complete as per the direction of Engineer-in-charge. |
| 38 | Mending with Plain cement concrete (1:2:4) with 12mm size crusher broken hard Granite chips including cost of all labour and materials with all taxes,lead,T & P etc all complete. |
| 39 | HDPE PIPE: Supply and Laying of 40MM(8Kg/cm2)dia HDPE pipe (Make: Supreme/equvalent) in cable trench as per specification and directions of Site Engineer / Engineer-in-Charge. |
| 40 | Supply and Installation of pre-fabricated GRP Joint Box with lid size 600 x 600 x 600 mm for OFC loop and termination as per telecom specification and directions of Site Engineer / Engineer-in-Charge. |
| 41 | OFC: Supply and Laying of 12 core unarmoured Optical fibre cable ( OFC. Fiber glass with F-G 62.5/125micron, 2.6DB/KMF600) to various sites through HDPE pipe /in Air ( pole to pole ), prelaying testing of each cable drum for each fibre and tahing the OTDR traces,submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/Site Engineer. |
| 42 | Supply and Installation of OFC jointing kits as per drawings,specificationsanddirections of Engineer-in-charge/Site Engineer. |
| 43 | Laying HDPE Pipe by HDD method using HDD machine upto 90mm dia including hire charge of HDD machine, operator, POL lubricant etc |
| 44 | Provision for supplytesting & commissioning of chemical feed pump0 to 100m³/Hr in proportion to 4 to 20 mA signal. 100 SPM @ 75 HZ and 67 SPM @ 50 HZ. Motor Frequency Range = 15 to 75 Hz Auto/Manual, Remote, while running or at rest, 5:1 Turn Down Ratio, Over & above there will be provision for manual stroke variation.The Disch piping & fittings starting from the pump flange upto the tank nozzle including VFD 3 Phase input and 415 V 3 Phase output and will have a rating of 3 HP. Inverter will receive a signal of 4 to 20 mA and will vary the RPM of the motor in proportion to the same, thus controlling the pump capacity. Pump will also have the provision for manual stroke adjustment. Connection between theInverter & pump together with the Instrument for generating 4 to 20 mA signal witheletrical installation etc all complete. |
| 45 | 1set=2 nos dosing pump (1 no working + 1 no standby) |
| 46 | Installation charges including all piping arrangement & hire charges of Hydra etc all complete |
| 47 | Supplying of control panel with VFD for running of the above chlorine dosing pump and motor etc all complete as per direction of Engineer-in-Charge. |
| 48 | Supply, of On line Chlorine Analyser with following technical specification |
| 49 | i.e.Single Channel free Chlorine Analyser,Transmitter-Aqua4trans DualChannel,FRC sensor FMNSX5 with 10 feet cable(with manual PH compensetion),Complete system pre mounted on plate with FTCs foe sensors,Power supply110-240VAC,Trans 2\" pipe/wall /Panel mount type,RangeFRC-0-5 ppm,Complete plate mounted system,(The Analyzer must be pre wired on plate,we will provide only power supply & pipe connection system) |
| 50 | Charges for installation, Testing & commissioning ofOn line Chlorine Analyser . |
| 51 | Design, engineering, procurement of materials and bought out components, manufacturing, assembly at shop, inspection, testing and painting at manufacturer’s works, packing, supply, unloading /transportation/ handling/storage at site, assembly at site, installation including touch-up painting, hook-up, pre-commissioning, commissioning, inspection and testing of the complete of the following capacity(Prime Power) DG sets along with AMF Panels, Acoustic enclosure, supply of all erection & commissioning spares, special tools and tackles (as required),instrumentation, allAuxiliaries, Exhaust system& silencer, Fuel Tank, Fuel piping , cable of required size , 4 nos earthingfor DG set, required foundation, good quality(L& T or equivalent) , change over,meetering panel, with CT Meter, all complete etc. with inspection certificate from electrical inspector and as as per site condition & direction of Engineer in charge. |
| 52 | 15KVA single phase DG set Disel operated having automatic feeder panel with display controller which can communicate oil level , engine temperature , voltage ,current , battery ,voltage , frequency hour meter , engine oil temp & should be liquid cooled engine . The controller should be fixed on a separate wall with connecting cable up to 15 mtr |
| 53 | Supply,Installation & Commissioning of SCADA software (Make-Schiender/Simens/Fox) with Graphical processor visualisation Advanced alaram management,historical and Real time trending,Built-in-reporting,Stastical process control,Multithreaded citect VBA and Cicode programming language including supply,installations of Desk top PC, Modem for receiving data, UPS etc all complete. |
| 54 | Supply, Installation, Testing,Programming, Wiring & CommissioningofPLC panel Made out of 2 MM C.R sheet,PLC Pannel with encloser size 800x600x2100mm Duely Powder coated, Wall mounted/floor standing, Front operated, complete with interconnection with copper wire and lugs.(Make-Rittal,BCH,Hoffman)Having Type 2-1P+N 15kA Surge protection device- 1Nos ,32A 15KA MCB - 1 nos, DC powered Transistor/Relay based24DI and 16DO EthernetPLC Module, 35 Micosecond Response time for DI/DO Switch on/off, 8ch Analog input module- 2 Nos having 1ms per channel conversion/sampling time. 4ChAnalog Output module - 2 Nos having 1ms per channel conversation/ stabilisation time. Ambient air tempature upto 55 \"C.10\"\" W touch Panel display having 2 ethernet, Usb host&device 24VDC type- 1 Nos (Make- Siemense ,Schneider-,Allen Bradly).Rated DP Separate DC MCB for Indivisual Modules.. 24dc 1C/O type slim Relay with Led for Digital out put - 16 Nos (make-wago,phoenix contact). 5 Ch Unmanaged Industrial Grade Switch- 1 Nos. (Make- wago,schneider,siemense,Allen Bradley) .4G ethernet TCP/IP-Modbus Industrial Grade GSM Router -1 Nos (make- Robustel,Teltonika). 1.5 mmFuse TB with 0.5A glass fuse with Fuse blown indicator type Terminal Block for Digital Input/analog output- 60. 1.5 mm Terminal block for Digital Output - 40Nos. (Make- wago,Phoenix Contact). 24VDC powered signal isolator for Analog Input - 16 Nos. (Wago,Phoenix), 24 Vdc 6Amp redundent Power supply Unit with input and output DC MCB - 2Nos ( Make- Wago,Phoenix Contact,Siemens,Schneider), Color Coded Terminal Blocks for AC/DC/earth Bus/TB- 50 Nos.(Make- Wago,Phoenix Contact,Connectwell),2/4/6 Amp AC/DC MCB- 6nos All switchgear and controlgear make- Siemens,schneider,ABB,L&T.All completed asper electrical specification and as per direction of EIC. |
| 55 | Type 2-1 P+N 15KVA Surge protection device |
| 56 | Supply, Installation, Programming, Testing& Commissioningof1KVA Online UPS with 08Hr Battery Backup System, Having Double conversion IGBT based online UPS system with builtin Isolation Transformer, Input 150-250VAc 1Phase,50Hz, output: 230 VAC,1Phase,50Hz. Drytype Battery with MS Rack . All completed asper electrical specification and as per direction of EIC. |
| 57 | Supplying all materials,labour,T&P, for fitting of PLC panel as per electrical specification |
| 58 | 1.5 sqmm 8 core armoured cable |
| 59 | 1.5 sqmm 3 core armoured cable |
| 60 | 0.75sqmm 2 core armouredInstrument(Screen cable) |
| 61 | CAT-6 Dlink cable |
| 62 | Cable Gland-25 mm |
| 63 | Cu.logs-1.5/2.5 |
| 64 | Supply, installation of chemical earthing withcrystalline conducting material for Back Fill Compound & installation of Maintenance Free Earthing Electrode with ISI mark G.I. Pipe dia 50mm as Secondary electrode with wall thickness of 2.6mm and the primary earthing electrode will be 25mm x 6mm hot dipped galvanized strip filled with a highly conductive & non-corrosive compound in between the primary earthing & the secondary earthing. A solid G.I. Base plate of 300 x 300 mm seals the unit at the bottom. Ground filling compound will be provided in 25kg per bag - 2nos. Excavation of earth pit refilling, Precast RCC chamber with lid etc. all completeas per the site requirement. |
| 65 | Supply of Level indicator to be installed at ESR with following specificationRange=0 to 8mtrType =Radar Power Supply=24V DCOut Put=4-20mAMake=E&H/ABB/VEGA |
| 66 | 4U wall-mount Rack/Cabinet shelf or self-standing & is great for organizing your DVR-NVR-Server-Network devices. 4U rack has a key lock feature for keeping your device safe in this cabinet. This rack is made with the highest care while making it. Since making its quality, best, 6-way processed powder coating is done for long-lasting, Corrosion and Rustproof. Top and bottom cable entry provides optimal flexibility for cable management. It also has 4 Power sockets surge protector and 1 AC AXIAL cooling Fan attached in it. Rack size: 45 X 55 X 25.5 CM. Weight: 9.20 kg. Colour: Gray. Package Contains 1 Rack, Screws, Nylon Sleeves, 2 Keys. |
| 67 | Gigabit SFP to RJ45 Fiber multi Media Converter | Fiber to Ethernet Converter | 10/100/1000Mbps RJ45 Port to 1000Base-LX Dual-Mode Fiber(Make - Dlink or equivalent) |
| 68 | 24 port fiber optic panel or light interface unit drawout Type |
| 69 | OFC Splicing with pigtails |
| 70 | Configuration of Electro Mechanical Instrument to PLC and Server level with data acquistion at interval of every 5 second including monitoring and command control from remote place |
| 71 | Optical fiber 16-port managed L3 gigabit fiber switch and media coverter for non-blocking throughput switching, high performance and low latency, Gigabit Ethernet SFP and RJ45 ports (Make- Digisol- SG-GS4600FSE or equivalent |
| 72 | Fiber SFP Multi mode transicever 100 base LC type module |
| 73 | SM(OS2) Duplex Patch cord 3mtr LC-SC,PC type |
| 74 | Fiber Pigtail/patchcord 1 mtr |