Special Repair / Replacement Of Walk In Cooler Against Ber And Certain Rev And Minor Work Under Ge Satwari
Tender Value
46 Lakhs
Estimated cost
Bid Submission
10 Aug 2022
0 days left
EMD
92000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
satwari → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Special Repair / Replacement Of Walk In Cooler Against Ber And Certain Rev And Minor Work Under Ge Satwari
BOQ
| Sl. No. | Item Description |
| 1 | Taking down old u/s Walk-in cold room of any size and specifiecation including freezer room and indoor and Outdoor unit and deposited to MES store yard all as specified and directed. |
| 2 | Supply, installation, testing and commissioning of Walk-in-cold roomof size 12\" (L) X 10\" (B) X 8\" (H)consisting of wall and ceiling panel madeoutofPPGIsheet (Thickness 0.40mm ) inside and Outsidefilledwith60mmthick PUF insulation having PUF density of 40 Kg Per Cubic Meter, with aluminium chaqured plate anti skid flooring on 60 mm thick Cyclopententane Panel (CFC free/ HCFC free) with 60 mm thick cyclopentane doors with size 34 Inches X 78 inches clear opening, flush type swing door, PPGI Inside and PPGI outside Evaporative Unit (With controlers) with SS304 grade stainless steel outer body : Qty 02 Sets (one working and one stanby) with 20000 Btu/h or nearest higher size as per OEM cooling capacity Condensing unit having hermetic reciprocating compressor of emersion Copeland -02 sets with R-22/R-404 Eco friendly refrigerant suitable for AC 415V/ 3 Phase/ 50 Hz for each refrigeration machineto maintain temperature of4 ± 2 degreeCentigradeatan ambient temperature of 45 degree centigrade, Products to be stored: Medicine, Product incomming temprarture: + 35 degree C all as specified and directed.Make : Voltas/Blue Star/ Hitachi / Carrier / Daikin /O-GeneralNote : Unit rate shall also include the following :(i) Copper pipe along with insulation and electrical cable of apropriate size between indoor and outdoor of machine(ii) Any Civil and Structural Works such as foundation works, making opening / closing in the wall / slab, RCC over Floor insulation, service platform or support for condensing units. (iii) The cost of Structural supports for Refrigeration units/ Evaporators and Panels etc. |
| 3 | Supply, installation, testing and commissioning of Walk-in-cold roomof size 8\" (L) X 8\" (B) X 8\" (H)consisting of wall and ceiling panel madeoutofPPGIsheet (Thickness 0.40mm ) inside and Outsidefilledwith60mmthick PUF insulation having PUF density of 40 Kg Per Cubic Meter, with aluminium chaqured plate anti skid flooring on 60 mm thick Cyclopententane Panel (CFC free/ HCFC free) with 60 mm thick cyclopentane doors with size 34 Inches X 78 inches clear opening, flush type swing door, PPGI Inside and PPGI outside Evaporative Unit (With controlers) with SS304 grade stainless steel outer body : Qty 02 Sets (one working and one stanby) with 10000 Btu/h or nearest higher size as per OEM cooling capacity Condensing unit having hermetic reciprocating compressor of emersion Copeland -02 sets with R-22/R-404 Eco friendly refrigerant suitable for AC 415V/ 3 Phase/ 50 Hz for each refrigeration machineto maintain temperature of4 ± 2 degreeCentigradeatan ambient temperature of 45 degree centigrade, Products to be stored: Medicine, Product incomming temprarture: + 35 degree C all as specified and directed.Make : Voltas/Blue Star/ Hitachi / Carrier / Daikin /O-GeneralNote : Unit rate shall also include the following :(i) Copper pipe along with insulation and electrical cable of apropriate size between indoor and outdoor of machine(ii) Any Civil and Structural Works such as foundation works, making opening / closing in the wall / slab, RCC over Floor insulation, service platform or support for condensing units. (iii) The cost of Structural supports for Refrigeration units/ Evaporators and Panels etc. |
| 4 | Supply and fix servo voltage stabiliser for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilised at 415 V with accuracy ±1% and speed of correction 8 Volts per second and of capacity 50 KVA all as specified with fwg specification:Type : unbalanced mains, unbalanced loadEfficiency : More than 98%Winding materaial : Copper EC Grade (99.9% pure)Degree of Protection : IP 30Operating temperature : -20 deg to 50 degNo load losses : Less than 0.4%Make : ITE Gurgaon, Volina, Sinetrac, Vinitec, IECO |
| 5 | Supply, laying and testing cable XLPE PVC insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core all as specified. |
| 6 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of pipes etcnot exc 10 Sqm on plan and not exc1.5m in depth and getting out in soft loose soil all as specified and directed. |
| 7 | Returning filling in, trenches including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified. |
| 8 | Removing excavated surplus materials to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point. |
| 9 | Supply and spreading sand Dry cushioning to cable providing with a layer of sand 8cm deep before laying the cable and 15cm deep after laying and stretching the cable in trenches complete all as specified and as directed by the Engineer-in-Charge. |
| 10 | Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid. |
| 11 | Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5mbelow normal ground level, connected ot galvanised iron strip of size 32 x 6 mm earth lead by means of bolt, nuts, washers of galvanisediron or steel, earth strip protected by and including GI pipe 40mm dia bore (light grade) and connected to main test point as directed including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:1½:3) type A-1 cover slab of size 54 x 54 x 5 cm reinforced with 8mm dia TMT bars @ 150 mm C/C both ways with one handle for lifting, made out of 8mmdia TMT bar embedded in precast cover slab, funnel, wire mesh, 20mm bore GI pipe (medium grade) for watering, charcoal and salt in alternate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No 5 of SSR Part-I and testing complete all as specified and as directed. |
| 12 | Supply and fix triple pole and neutral 4 way DB double door AC 430 Volt incl necessary connection all as specifed and directed. |
| 13 | Supply and fix single pole and neutral 4 way DB double door AC 230 Volt incl necessary connection all as specifed and directed. |
| 14 | Supply, installation, testing & commissioningair cooled split unit air conditioner electric driven AC 230 V, 50 Hz single phase of capacity 1.5 TR, BEE3 Star rated with cooling and intelligent heating facility incl its fixing accessories with fwg specification:Rated cooling capacity: 18000 Btu/Hr, Rated Current cooling : 7.8 Amp, Rated heating capacity: 18000 Btu/Hr, Copressor type: High EER twin Rotary, Anti dust/Anti-bacterial Filter, Dehumidifier, Refrigerant gas: R32, Operation: LCD Remote with self dignosis facility all as specified and directed. Make: Voltas,Model: 183 VH SZS or its equivalent in Hitachi / Carrier / Daikin /O-General.Note: Rate includes powder coated stand (bracket) for fixing of outdoor unit and cutting, chasing of wall/surgace and making goodas per site requirement. |
| 15 | Supply and fix Voltage stabiliser buck boost type, copper wound, wall mounted type for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilised at 230 V with accuracy of ± 2.5 % and of capacity 4.0 KVA incl inbuilt voltmeter with time delay relay all as specified and directed.Make: V-Guard VGX 400 or its equivalent in Blueline, Bluebird, Powerware, Vinitec. |
| 16 | S&F single pole and neutral enclosures with a two pin and earth plug and socket complete with SPNMCB 20 Amp all as specified and directed.Make: Havells Cat No. DHDPUSN020/DHDPUDP020 or its equivalent in Legrand, C&S |
| 17 | S&F sub main wiring with single core cable 4 x 10 sq mmFRLSinsulated unsheathed stranded copper conductor cable 1100 Volts grade in rigid PVC conduit (Concealed)medium grade alongwith 1x10 Sq mm FRLS insulated unheathed stranded copper conductor cable as earth wire connected with main earth dolly including chiseling, cutting & making good to match with the existing surface complete all as specified and directed. |
| 18 | Supply and fix RCOBs four pole 300 mA of cap 32 Amp all as specifed. |
| 19 | Supply and fix RCOBs four pole 300 mA of cap 63 Amp all as specifed. |
| 20 | Supply and fix MCCB 63 Amp 4 pole, 415 v, 50 Hz 25 KAthermal based release all as specifed. |
| 21 | Supply and fix MCCB 125 Amp 4 pole, 415 v, 50 Hz 35 KAthermal based release all as specifed. |
| 22 | Supply & fixing geysers of capacity 25 Ltr vertical storage typeelectric driven AC 230 Volt single phase BEE 5 star rating, rated pressure: 0.8 Mpa, inner tank: ultra-thick super cold rolled steel plates with CFC free thicker PUF insulation and incoloy glass-coated heating element 2000 wattincluding its fixing accessories complete all as specified and directed.Make : Havells Model No Monza DX or its equivalent in Crompton, Venus, Usha, Jaguar |
| 23 | Supply and Fixing sub main wiring with single core cable 2 x 2.5 sq mmFRLS insulated Unsheathed stranded copper conductor cable 1100 Volts grade in rigid PVC conduit (Concealed type)medium grade alongwith 1x 2.5 Sq mmFRLS insulated unheathed copper conductor cable as earth wire connected with main earth dolly including chiseling, cutting & making good to match with the existing surface complete all as specified and directed. |
| 24 | Supply and Fixing Power unit with 20 Amp mini MCB and plug modular type (in 3 module) concealed type all as specified and directed. |
| 25 | Supply and Fixing GI pipe medium grade with complete fittings for 15 mm bore size fixed complete to walls and ceilings or lais in floors all as specified. |
| 26 | Supply and Fixing angle stop valve cast copper alloy chromium plated screwed down, high pressure crutch or butter fly handle screwed both ends for iron pipe of size 15 mm all as specified. |
| 27 | Supply and Fixing PVC Connection15mm size with PTMT nuts of length 600mm for inlet/ outlet water connection to Geyserall as specified directed. |
| 28 | Supply and Fixing Bib taps, cromium plated cast copper alloy with crutch or butterfly handle, chromium plated screwed down screwed for iron pipe or for brass ferrule and fixed of 15 mm dia all as specified directed. |
| 29 | Taking down old U/s Point wiring including switches socket and fitting fixtutres all as pecified and directed |
| 30 | M&L for point wiring with 1.5 sqmm (Nominal Area) FR-LS PVC insulated sheathed multistranded copper conductor, 1100 Volts grade through PVC conduit medium duty (ISI Marked) concealed with accessories such as bends, cross, elbow, tees etc. of suitable sizeincluding MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting Modular type switches, sockets, fan regulators etc modular top cover (ISI marked) including continuous earth wire FR-LS PVC insulated unsheathed 1.5 Sq mm(nominal area) copper conductor multistarnded, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for the following :(a) For one light point/ fan/exhaust/bellpointcontrolled by one switch. |
| 31 | (b) For one three pin socket outlet on same board. |
| 32 | (c) For one 3 pin modular socket outlet 6 amp independent. |
| 33 | M&L for point wiring with 2.5 sqmm (Nominal Area) FR-LS PVC insulated sheathed multi stranded copper conductor, 1100 Volts gradefor 3 Pin socket outlet 15Amps on independent board through MS conduit medium duty (ISI Marked) concealedwith accessories such as elbow, tees,internal & external bend etc. of suitable sizeincluding MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting Modular type switches with modular top cover including continuous earth wire FR-LS PVC insulated 2.5 Sq mm copper multi stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified. |
| 34 | Supply and fix modular switch 6 Amps, 1 module complete |
| 35 | Supply and fix modular switch 16 Amps, 1 modulecomplete |
| 36 | Supply and fix modular socket out 6 Amps, 2 modulecomplete |
| 37 | Supply and fix modular socket out 16 Amps, 2 modulecomplete |
| 38 | Supply and Fixing modular type fan regulator 2 Moduleall as specified and directed. |
| 39 | Supply and Fixing modular bell pushtype one way 6 Amp 1 module all as specified and directed. |
| 40 | Supply and fixing bell Ding Dong AC 230 volts Single Phase all as specified and directed. |
| 41 | Supply and Fixing ceiling rose surface bakelite 65x50 mm three terminals, 240 V grade complete all as specified and as directed. |
| 42 | Supply and fixing lamp holder, Polycarbonate type with back plate suitable for batten fittingsall as specified and as directed. |
| 43 | Supply and Fixing Vertical Distribution Board (TP&N) 4 way double door suitable forMCCB 3/4 pole of cap upto 125 Amp as incomer and out going MCBs SP and should be IP 43 protected with Copper Bus Bars, Neutral Links, Earthing bar all as specified and directed. |
| 44 | Supply and Fixing sheet metal enclosure for MCB\"s DBs single pole & neutral 240V AC with 200 Amp rated neutal bus bar suitable for 8 ways outgoing MCBs with IP - 42 protection completeall as specified & directed. |
| 45 | Supply and Fixing MCB single pole 240V AC 10 KA \"C\" series of cap 6-32 Amp all as specified & directed. |
| 46 | Supply and Fixing MCB single pole & neutral240V AC 10 KA \"C\" series of cap 32 Amp all as specified & directed. |
| 47 | Supply and Fixing MCCB 63 Amp 3 pole 415 V fixed type with breaking capacity 16 KA all as specified & directed. |
| 48 | Supply and fixing LED lightfitting 1 x 20 Watt, 220 V AC decorative box type aluminuium housingwith integreted electronic driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed. |
| 49 | Supply and fixing LED lightfitting 1 x 10 Watt, 220 V AC decorative box type aluminuium housingwith integreted electronic driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed. |
| 50 | Supply, laying and testing cable XLPE PVC insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm x 4 core all as specified & directed. |
| 51 | Supply and laying GI pipe light grade 50 mm dia with all fittings laid in trenches all as specified. |
| 52 | S&F Exhaust fan metalic body AC single phase 230 V of size 300 mm sweep with, blades, and frame and louversall as specifed. |
| 53 | M&L for cutting of wall of any thickness for fixing of Exhaust fanandmakinggood of exsiting surface incl. match with exixting surface by plastering & painting complete. |
| 54 | Supply and fixing ceiling fan complete with blade, down rods and accessories, 230 V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushlessdirect current motor (BLDC) and connected from ceiling rose/ connector with & including suitable size flexible copper conductor PVC insulated sheathed cord, complete. |
| 55 | S&F hook type anchor fastener to hanging of ceiling fan all as specified and directed. |
| 56 | S&F sub main wiring with 2 X 6 sqmmsingle core PVC insulated,unsheathed, stranded copper conductor cable with 1 x 6 Sqmm PVC insulated, unsheathed, stranded copper conductor cable as earth wire in and including rigid PVC conduit 25mm dia or higher, medium grade ISI marked and earth wire connected to common earth point all as specified & directed. |
| 57 | Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5mbelow normal ground level, connected ot galvanised lead wire 4.0 mm thick dia earth lead by means of bolt, nuts, washers protected by and including GI pipe 15mm dia bore (light grade) and connected to main test point as directed including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:1½:3) type A-1 cover slab of size 54 x 54 x 5 cm reinforced with 8mm dia TMT bars @ 150 mm C/C both ways with one handle for lifting, made out of 8mmdia TMT bar embedded in precast cover slab, funnel, wire mesh, 20mm bore GI pipe (medium grade) for watering, charcoal and salt in alternate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No 3 of SSR Part-I and testing complete all as specified and as directed. |
| 58 | Supply, install, testing & commissioning of wall mounted water purifier of fwg specification: RO + UV + UF + TDS controler + UN in Tank + Digital Display, Purification capacity: Not less than 15 ltrs/Hr as per OEM, Tank cap not less than 6.5 Ltr with low wastage of water, Input Voltage: 180-230 Volts AC (50 Hz) all as specified and directed.Make : Kent RO, Aquaguard, Livpure, AO Smith, Havells |
| 59 | Supply and fix SMF battery of cap 12 V, 26 AH or nearest higher size as per OEM including necessary connection with exsting wiring all as specifed. Make : Exide, Amaron, Okaya, Luminous |
AI Tender Summary
Tender Timeline
Jul 27, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 12, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender