Maintenance Of Summer Appliance Including Replacement Of Defective Spares And Allied Works And Rep Replcmnt Of Intrnl Wiring Incd Fitting Fixture With Connected Accessories Of Ac Installations Tunir And Out Side Area Under Age Emii Ge Nw Karanja- 1 Serv, karanja-Maharashtra

Military Engineer Services-MES has published Maintenance Of Summer Appliance Including Replacement Of Defective Spares And Allied Works And Rep Replcmnt Of Intrnl Wiring Incd Fitting Fixture With Connected Accessories Of Ac Installations Tunir And Out Side Area Under Age Emii Ge Nw Karanja- 1 Serv. Submission Date for this Tender is 29-09-2022. Coats and Jackets Tenders in karanja Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

33283694
Corrigendum : Maintenance Of Summer Appliance Including Replacement Of Defective Spares And Allied Works And Rep Replcmnt Of Intrnl Wiring Incd Fitting Fixture With Connected Accessories Of Ac Installations Tunir And Out Side Area Under Age Emii Ge Nw Karanja- 1 Serv
Open Tender
Indian
Maharashtra
karanja
29-09-2022

Tender Details

Maintenance Of Summer Appliance Including Replacement Of Defective Spares And Allied Works And Rep Replcmnt Of Intrnl Wiring Incd Fitting Fixture With Connected Accessories Of Ac Installations Tunir And Out Side Area Under Age Emii Ge Nw Karanja- 1 Servicing / Preventive Maintenance Of The Following Equipments Of Different Capacitiesby Carrying Out Regular Maintenance Such Aschecking Of Cooling Coils, Condensers, Electric Motors Of Different Types And Compressors And Other Parts, Cleaning Washing With Suitable Cleaning Agent / Chemical Using Vacuum Cleaner, Replacement Of Rubber Wheels, Bolts & Nuts, Screws Check Nuts, Pvc Sleeves And Thimbles, And Other Parts As Required, Checking All Electrical Parts And Electrical Wiring Etc, Tightening Of Electrical Connections, Greasing Of Electric Motors, Checking Of Gas Pressure And Gas Charging To The Desired Pressure To Ensure Serviceability Regularily Through Out The Contract Period All As Specified And As Directed. 2 ( A ) 1.5 / 2.0 Ton Capacity Window Type Acs 3 ( B ) 1.5 / 2.0Tons Capacity Split Type Acs 4 ( C ) 2.0 / 3.0Tons Capacity Casset Type Acs 5 ( D ) Water Coolers Ofany Capacity 6 ( E ) Refrigerators Capacity 165 To 310 Ltr 7 ( F ) Deep Freezers Up To 400 Ltr 8 ( G ) Ice Making Machine 250 Ltr 9 Taking Out Sealed / Old Burnt Compressor Of Window Type Ac 1.5 Ton Of Approved Make And S&F New Sealed Compressoras Per Reciprocating Type Suitable For 1.5 Ton Capacity Ac And Connecting Up Suction And Discharging Pipe Line With Gas Welding Complete All As Specified And Directed By Engineer-In-Charge. Make: M / S Kirloskar / M / S Carrier / M / S Voltas / M / S Bluestar Or As Approved By Ge. 10 All As Per Item No. 2.00 Butsplit Type Ac 1.5 Toncapacity Complete All As Specified And As Directed 11 All As Per Item No. 2.00 But Split Type Ac 2 Toncapacity Complete All As Specified And As Directed. 12 Taking Down Split Type Ac And Taking Out Rotary Type Sealed Compressor Of Split Type Ac 1.5 Ton Capacity Of Approved Make And S&F New Sealed Rotary Type Compressor Suitable And Discharging Pipe Line With Gas Welding And Refixing The Repaired Ac In Its Original Position Complete All As Specified And Directed By Engineer-In-Charge 13 All As Per Item No. 5.00 But Split Ac 2.0 Ton Capacity Complete All As Specified And As Directed. 14 S & F Inrepairs Copper Cooling Coil Assembly For 1.5 Tonair Conditioner Of Approved Makeincluding Testing And Commissioning Complete All As Directed By Engineer-In-Charge. 15 S & F In Repairs Of Copper Cooling Coil Assembly For 2.0 Ton Air Conditioner Of Approved Make, Commissioning Complete All As Specified And As Directed. 16 S & F Inrepairscondenser Coil Assembly Suitable For 1.5 Tonair Conditioner Including Testing And Commissioning Complete All As Specified And As Directed. 17 S & F Inrepairscondenser Coil Assembly Suitable For 2.0 Tonair Conditioner Including Testing And Commissioning Complete All As Specified And Directed. 18 Supply & Fixing In Replacementof Unserviceable Split Type Air Conditioner Indoor Unit Suitable For 1.5 / 2.0 Ton Invertor Type As Per Existing Make & Sizecomplete With Remote Assy All As Specified & Directed By Engr-In-Charge.Make : Carrier / Hitachi / Voltas / Daikin / Panasonic / Bluestar 19 Note For Item Nos 2.00 To 11.00 :- ( A ) Contractor Will Provide Guarantee For At Least One Year For Replaced Compressor Unit. Compressor Should Be Sealed With Original Manufacturers Packing Having Reputed Make All As Approved By Engineer -In -Charge. ( B ) Gas Charging Will Be Measured And Paid Separately Under Relevant Items As Described. Gas Charging Will Be Measured And Paid Only Once For Entire Contract Period While Initial Charging Of Compressorand Subsequent Leakage / Topping Up Shall Be Made Good By The Contractor At His Own Cost Through Out The Contract Period. 20 S & F In Repairs Running Capacitor 36 Mfd, 3 Pole & 2 Pole Suitable For 1.5 Ton Window / Split Type Air Conditioner. Make M / S Asian / M / S Unistar / M / S Epcos / M / S Electro All As Specified And As Directed. 21 S & F Inrepairsrunning Capacitor 45 Mfd, 3 Pole & 2 Pole Suitable For 2.0 Ton Window / Split Type Air Conditioner. Make M / S Asian / Ms Unistar M / S Epcos / M / S Electro All As Specified And As Directed. 22 S & F Inrepairs Starting Capacitor 100 To 120 Mfd Suitable For 1.5 Ton Window / Split Type Air Conditioner. Make M / S Asian / M / S Unistar / M / S Epcos / M / S Electro All As Specified And As Directed . 23 S & F Inrepairsstarting Capacitor 100 To 150 Mfd Suitable For 2.0 Ton Capacity Window / Split Type Air Conditioners. Make M / S Asian / Ms Unistar M / S Epcos / M / S Electro Complete All As Specified And As Directed. 24 S&F In Repairs Starting Relay Suitable For 1.5 Ton / 2.0 Ton / 3.0 Ton Of Split / Window Type Ac Make M / S Sriram / M / S Renutral All As Specified And As Directed. 25 S & F Inrepairsof Thermostat Switch For Window / Split Type Air Conditioner Of 1.5 / 2.0 / 3.0 Ton Capacity. Make M / S Renutral / M / S Denfoss All As Specified And As Directed. 26 M & L For Gas Charging R-22 In Window Type Ac 1.5 Ton Capacity Of Approved Make And Type Including Pressure Testing, Leakage, Vaccumising, Rectification, Testing And Commissioning Complete All As Specified And As Directed. 27 All As Per Item No 19.00 But 2.0 Ton Capacity Complete All As Specified And As Directed. 28 All As Per Item No 19.00 But Split Type Ac 1.5 / 2.0 / 3.0 Ton Capacity Complete All As Specified And As Directed. 29 Taking Down Window Type / Split Type Air Conditioner Of Any Type / Make / Capacity From Site ( Either In Ground / Any Floor ) , Transporting To Work Site Opening Top And Side Cover, Dismantling All Electrical Controls And Components And Cleaning The Whole Unit With Electric Blower And Spray Cleaning With Water, Descaling With Acid In Both Side Of Cooling Coil And Components, Refixing The Covers And Making Electrical Connections, Installation Of The Machine In Same Location, Testing, Commissioning Complete All As Specified And As As Directed.Note :- Spares Required For Repair Will Be Measured And Paid Seperately Under Relevent Item Of This Schedule. 30 Shifting Of Split Type Air Conditioner Of Any Type And Make, Up To 2 Tr From Existing Location To Other Location And Installingindoor And Outdoor Units As Directed Including Provision Of Necessary Brackets ( L Type ) Clamps, Gi Nuts, Bolts And Washers Etc For Fixing Of Indoor / Outdoor Units Including Topping Up Of Refrigerant Gas And Nitrogen Pressure Test To Find Out Leakage, Commissioning And Testing And Making Good Disturbed Surface Complete All As Specified & Directed.Note : ( I ) Pvc Pipe For Protection , Drain Pipe , Control Cable, Extra Copper Tubing Of Any Sizefor Suction / Discharge Will Be Measured And Paid Separately. ( Ii ) Gas Charging Will Be Measured And Paid Only Once For Entire Contract Period While Initial Charging Of Compressorand Subsequent Leakage / Topping Up Shall Be Made Good By The Contractor At His Own Cost. 31 Shifting Of Window Type Air Conditioner Of Any Type And Make, Up To 2 Tr From Existing Location To Other Location And Installingas Directed, Commissioning And Testing Including Making Opening Of Required Size In Walls Or Existing Windows Of Any Type, Provision Of Necessary Brackets, Clamps, Gi Nuts, Bolts And Washers Etc For Fixing Of Ac, And Making Good Disturbed Surface Of Walls And Windows Complete All As Specified & Directed. Note : ( I ) Pvc Drain Pipe , Control Cable Where Required Will Be Measured And Paid Separately. 32 S & F In Repairselectric Wiring Kit ( Pcb ) Suitable For 1.5 Ton / 2.0 Ton Window Type / Split Type Air Conditioner Of Any Make And Type Complete All As Specified And As Directed.Note: New Pcb Shall Be As Per The Existing One. 33 Supply In Replacement Remote Assembly Cordless As Per Existing Make And Size Window / Split Type AcS As Per Ac Make Complete As Specified. 34 Taking Down Corroded Body Base Tray Etc Of Window / Split Type Acof 1.5 Ton / 2 Ton Capacity And Replacement Of Body Base Tray Etc Made Out Of 18 Swg Mild Steel And Other Portion Of Mild Steel Sheet Of 20 Swg Including Motor Mounting Frame Fix With Nuts And Bolts Of Suitable Size And Painting With One Coat Of Black Enamel Paint And Necessary Insulation Complete All As Specified And As Directed. Note :- Unit Rate Quoted Shall Also Deemed To Include For Reassembling. 35 S & F Inrepairsof Fan Blade Of Motor For Window Type Ac Of Capacity 1.0 Ton / 1.5 Ton / 2.0 Ton Of Make M / S Asian Or Equivalent Complete All As Specified And As Directed. 36 S & F In Repairsblower Fan Motor For 1.0 Ton / 1.5 Ton / 2.0 Ton Capacity Air Conditioners Including Testing, Complete All As Specified And As Directed. Make:Blower Fan Motor Shall Be As Per The Existing One. 37 S & F Inrepairsblower Drum Suitable For Window Type Ac Of Capacity 1.0 Ton / 1.5 Ton / 2.0 Ton Completeall As Specified And As Directed. Note: Blower Drum Shall Be As Per The Existing One. 38 S & F Inrepairsfront Cover Grill Suitable For Window Type Air Conditioner Of Capacity 1.0 Ton / 1.5 Ton / 2.0 Ton, Complete All As Specified And As Directed 39 S & F Inrepairsouter Cover Suitable For Window Type Air Conditioner Of Any Capacity Complete All As Specified And As Directed. 40 S & F Inrepairsblower Motor Capacitor 4 Mfd Suitable For 1.5 Window Type Air Conditioner Complete All As Specified And As Directed. 41 S & F In Repairsblower Motor Capacitor 10 Mfd Suitable For 1.5 Ton Split Type Air Conditioner Complete All As Specified And As Directed. 42 S & F Inrepairsblower Motor Capacitor 15 Mfdsuitable For 2.0 / 3.0 Ton Split Type Air Conditioner Complete All As Specified And As Directed. 43 Supply, Fixing, Clamping And Jointing Copper Tubing Of Standard Size 1 / 2, 5 / 8 For Suction Line And Liquid Discharge Line Of Suitable Size 1 / 4 Duly Insulated With Suitable Insulation Materials Including Making Hole In Any Type Of Wall For Passing Through Pipe Andmaking Good To The Disturbed Surface As In Replacement And Colour Matching As Per Existing Shade, Complete All As Specified And As Directed. 44 Supply And Fixing In Replacement Cable Pvc Insulatedpvc Unsheathed, Multistranded, 1100Volts Grade ( Isi Marked ) 3 Core 2.5 Sq Mm With Flexible Copper Conductor Suitable Forsplit Type Ac And Window Type Ac Complete All As Specified And As Directed. Make:- Havells, Polycab, Plaza. 45 Supply And Fixing Suitable Size Pvc Pipe, Heavy Duty For Drain Out Of Condensing Water Of Split Type Air Conditioner Including Cutting Of Floors Or Making Hole In Wall And Making Good The Disturbed Portion After Laying Pipe Etc To Match The Existing Surface With Original Specifications Complete All As Specified And As Directed. 46 S & F Inrepairssynthetic Air Filter Suitable For Split / Window Type Air Conditioner Any Capacity Complete All As Specified And As Directed 47 Servicing, Cleaning Of Solar Water Heater System By Dismantling Inlet And Outlet Connection, Washing With Suitable Cleaning Agent Castic Soda, Arresting Leakage And Refixing The Same After Replacement Of Bush, Nut, Bolts, Washers, Painting Of Rusted Surfaces If Any Making Serviceable To Desired Satisfaction Level Complete All As Specified & Directed By Engineer-In-Charge. 48 Water Coolerstaking Down Sealed Compressor Of Water Cooler Of Approved Make Of Capacity 40 / 80 Ltrs And Supply And Fixing In Replacement Company Repaired Sealed Unit Caj 3612 Or Ae 4440 Of M / S Kirloskar Or Equivalent And Connecting Up Suction And Discharge Copper Pipe With Gas Welding Pressure Testing Of Leakage Rectification, Vaccumising And Charging The Refrigerant Gas Including Testing & Commissioning Complete All As Specified And As Directed. 49 All As Per Item No 41.00But Capacity 60 / 120 Ltrs Complete All As Specified And As Directed. Make : Bpk Kce 461 Of M / S Kirloskar Or Equivalent In Ps. 50 S & F In Replacement Starting Capacitor 40 / 60 Mfd Complete All As Specified And As Directed. Make - M / S Asian, M / S Unitstar, M / S Tibcon, M / S Telsa 51 S & F Inrepairsstarting Capacitor 80 / 100 Mfdcomplete All As Specified And As Directed. Make – M / S Asian, M / S Unistar, M / S Tibcon, M / S Telsa. 52 S & F Inrepairsof Thermostatic Switch For Water Cooler Complete All As Specified And As Directed. Make – M / S Renutral , M / S Ind-Foss, M / S Annapurna ( Aes ) . 53 S&F Inrepairs Of Condenser Fan Motor 1 / 35 Hp 230 Volt Ac Single Phase Suitable For Water Cooler All As Specified And As Directed.Make – M / S Crompton Greaves, M / S Khetan, M / S Ave, M / Sface Master. 54 All As Per Item No 46.00But 1 / 83 Hp Complete All As Specified And As Directed. 55 S & F Inrepairsrelay For Water Cooler Of Capacity 40 / 80 Litres And 60 / 120 Litres Capacity All As Specified And As Directed. 56 S&F Inrepairsof Fan Blade Suitable For Existing Water Coolerof Any Capacity, Approved Make And Type Complete All As Specified And As Directed. 57 S & F In Repairs Push Cock / Lifting Cock Of 15 Mm Dia Chromium Plated Suitable For Water Cooler Of Capacity 40 / 80 Litres & 60 / 120 Litres Complete All As Specified And As Directed. 58 Detecting The Gas Leakage, Rectifying The Defects, Vacumizing And Charging Fresh Refrigerant Gas And Commissioing And Testing The Water Cooler Of Capacity Upto60 / 120 Litre Capacity , Complete All As Specified And As Directed. 59 S & F Inrepairs Of Water Tray Stainless Steelgrade Ss 304 Of 40 / 80 Ltr Capacity Complete All As Specified And As Directed. 60 All As Per Item No 52.00 But Capacity 60 / 120 Ltrs Complete All As Specified And As Directed. 61 S&F Inrepairsof Rubber Packing And Hinges Of Top Cover Of Water Cooler Of Any Makeand Capacity Complete All As Specified And As Directed. 62 S & F In Repairs15 Mm Dia Isi Marked Float Valvebrass Of Make M / S Prayag / M / S Rojari Or Equivalent, All As Specified And As Directed. 63 S & F Inrepairsover Load Protector For Watercooler Of Any Capacity Complete All As Specified And As Directed. 64 S & F In Replacement Pvc Connecting Pipe With Brass Nuts& Washers At Both Ends Oflength Not Exceeding 60 Cm For Water Connection Of Water Coolers Complete All As Specified And As Directed. 65 S & F Suitable Size Pvc Drain Pipe Flexible Heavy Duty With Necessary Saddles And Fitting For Drain Out Water From Water Cooler Complete All As Specified And As Directed. 66 Refrigeratorstaking Down Sealed Compressor Of 165Ltr / 175 Ltrs Capacityof Refrigerator Of Approved Make And Type And Replacement Of Hermetically Sealed Unit Of Compressor Of Samesize And Type And Capacity , Connecting Sealed Unit And Dischargepipe With Gas Welding And Soldering Rod Complete All Specified And As Directed. 67 All As Per Item No 59.00 But 286 / 300 / 310 Ltr Capacitycomplete All Specified And As Directed. 68 S & F Inrepairs Thermostat Switch For Refrigeratorof Any Capacity, Complete All As Specified And As Directed. 69 S&F Inrepairs Over Load Relay / Protector Suitable For High / Low Speed Refrigerators Of Unit Of Compressor 165 / 230 / 286 / 300 / 310 Ltr Capacityof Refrigerator All As Specified And Directed. Make: -M / S Renutral / M / S Sriram / M / S Kelvinator / M / S Godrej / M / S Kirloskar 70 S&F Lamp 15 Watt Or Any Watt Screw / Pin Type Suitable For Approved Make And Capacity Refrigerator Complete All As Specified And Directed By E In Charge. Make: M / S Godrej / M / S Kelvinator. 71 M&L For Charging Of Refrigeratorrefrigerant Gas R-134A / R-410A Suitable Gas After Vaccumising / Pressure And Leaking Including Flushing The System In The Refrigerator Of Any Make Of 165 Litre Cap All As Specified And As Directed. Note:- Gas Charging For A Particular Machine Will Be Measured And Paid Only Once For Entire Contract Period While First / Initial Charging And Subsequent Leakage / Topping Up Shall Be Made Good By The Contractor At His Own Cost. 72 All As Per Item No 64.00But 230 / 286 / 300 / 310Ltr Capacitycomplete All Specified And As Directed. 73 S & F Inrepairsmagnetic Gasket For Refrigeratorof165 / 175 / 286 / 300 / 310 Litres Capacity All As Specified And As Directed. 74 S & F In Repairs Relay For Refrigeratorof Capacity 165 To 310Litresall As Specified And As Directed. 75 Supply And Fixing In Replacement Of Unservicable Freezer Chamber Existing Make & Size Forupto 165 To 195 Ltr Capacity Refrigerator Direct Cool Complete All As Specified & Directed. 76 Supply And Fixing In Replacement Of Unservicable Freezer Chamber Existing Make & Size For Refrigerator Frost Free Double Door Incl Heater, Blower Etc For 285 To 310 Litres Capacity. 77 M&L In Replacement Of Unservicable Condenser For Refrigerator As Per Existing Make &Any Capacity, Complete All As Specified And Directed. 78 M&L For Disconnecting The Electrical And Refrigerant Connections Of Defective Compressor Unit Ofdeep Freezer Of Capacity Upto 400 Ltrsand Replacing With New Compressor ( Refurbrished By Oem ) , Connectingthe Sealed Unit Both Electrical And Refrigerant Connections Including Charging Refrigerant Gas After Nitrogen Pressure Test To Find Out Leakage As Requiredcomplete All As Specified & Directed. Make Of Compressors : Kirloskar Complan / Tecumseh / Carrier. 79 Supply & Fixing In Replacementof Unservicable Condenser Fan Motor Box Typefor Deep Freezer Of Any Capacity / Size, Complete All As Specified And Directed. Make – M / S Crompton Greaves, M / S Khetan, M / S Ave, M / Sface Master. 80 Aircurtainstaking Down Defective / Unserviceable Air Curtain Of Existing Capacity And Existing Make, Transporting To Company Authorized Outlet, Collecting Company Repaired Air Curtain Of Same Make And Transporting Back To Site, Refixing At Original Posotion Complete Including Testing And Commissioning The Machine Onto The Mounting Plate And Ensure The Safety Than Fix It Tighten With Screw Complete All As Specified And Directed By Engr In Charge. 81 M&L For Replacement Ofwater Purifier Filter Kit Including Repair / Replacement Of Defective Parts Such As Filters, Solenoide Valve, Pump, Switch Complete Of Machine All As Directed By Engr-In-Charge. 82 M& L For Repair Of Voltage Stabilizer Of Capacity 5 Kva Including Replacement Of Burnt Out Transformer And All Accessories Complete All As Directed By Engr-In-Charge 83 Internal Electrification Taking Down Copper / Aluminium Point Wiring ( Light, Fan, Socket Or Power ) Complete, Including Fixture And Fittings Such As Switches, Ceiling Roses, Pendants, Lamp Holders, Regulators, Sockets, Light Fitting Any Type Etc Complete. Removing Materials To Store For Keeping In Safe Custody Or For Taking Credit ( Credit For Above Items Should Be Made As Per Conditions Separately ) And Making Good Disturbed Surfaces Of Walls, Floors, Etc Complete All As Specified And Directed By Eng.-In-Charge 84 Taking Down Mcb With Sheet Metal Enclosure, Main Switch, Db Etc And Making Good Disturbed Surfaces To Match With Existing Surfaces. 85 Taking Down Sub Main Wiring Of Any Size / Capacity Complete All As Specified And Making Good Disturbed Surfaces To Match With The Existing Surfaces 86 M&L For Point Wiring With1100 Volts, Grade 1.5 Sqmm. ( Nominal Area ) , Pvc Insulated But Unsheathed Multistranded Copper Conductor Single Core Frls Cable Drawn Through And Including Non Metallic Medium Duty Rigid Pvcconduit ( Medium Duty ) 20Mm Dia Or Higher Size Complete With All Accessories Such As Socket, Elbow, Junction Box, Bell Mouth, Bend, Reducer Etc Including Pressed Iron / Steel Suction Boxof Thickness1.2Mm For Mounting Of Switches, Sockets, Fan Regulators Etc With 3 Mm Thick Plastic Laminated Sheet As Top Cover, And 1.5 Sqmm. ( Nominal Area ) Single Core Frls, Pvc Insulated 1100 Volts, Grade Multi Stranded Unsheathed Copper Conductor Cable Green Colour As Earth Wire Upto Common Earth And Connected To Earth Dolly Complete All As Specified And Directed By Engr.-In-Charge Of Following. 87 ( A ) One Light / Bell / Exhaust Fan Pointcontrolled By One-One Way Switch. 88 ( B ) One Ceiling Fan Point Controlled By One-One Way Switch Through Regulator. 89 ( C ) One Three Pin 5 Amp Socket On Same Board With Other Switches. 90 ( D ) One Three Pin 5 Amp Socket On Independent Board. 91 All As Per Item No.79 Above But With 2.5 Sqmm. ( Nominal Area ) Wire / Cable For Phase And Neutral For One 3 Pin 15 Amp Socket On Independent Board Including One 1.5 Sqmm Pvc Insulated Unsheathed Multi Stranded Copper Conductor Cable, Frls 1100 Volts Grade As Earth Continuity Conductor Upto Common Earth & Connected To Earth Dolly Complete All As Specified And Directed By Eng.-In-Charge. 92 S&F Switch Piano Flush, Button Type 5 Amp Sp 250 Volt Ac Complete All As Specified & Directed. 93 S&F Switch Piano Flush Button Type 15 Amps Sp 250 Voltac Complete All As Specified & Directed. 94 S&F Socket Outlet Multipurpose 3 Pin 5 Amp And 2 Pin 5 Amps 250 V Ac Complete All As Specified & Directed. 95 S&F Socket Outlet 2-In1, 3 Pin 5 And 15 Amp Flush Type 250V Ac Complete All As Specified & Directed. 96 S&F Ceiling Rose Surface Bakelite 3 Terminals Of Size 65X25mm. Complete . 97 S&F Step Type, Electronic Fan Regulator 120 Watts, 5 Step For Ceiling Fan 1200 / 1400 Mm Sweep 230 Volts Ac. 98 S&F Lamp Holder Pvc / Polycarbonate Type With Led Lamp 9 / 10 Watt Complete All As Specified & Directed. 99 S&F Wall Mounted Led Tube Light Fitting 1X20 / 22 Watts Extruded Aluminiumpolycarbonate Covers Pf 0.9 And Above Operating Voltage 140V-270V Colour Temp 3000 K / 6500K & Lumen Input Output 95 Lumen Per Watt And Connected To Ceiling Rose With Required Length Of Two Core Flexible Copper Cable 23 / 0.0076 Fixed On Wall / Roof Complete All As Specified And Directed. 100 S&F Sheet Metal Enclosures 240 Voltwith Suitable Rated Bus Bar For Double Door 8 Way Ip-43 DbS Mounting Flush On Wall / Concealed And Making Good Distubed Surfaces Incl Taking Out Unserviceable Db Any Capacity. Complete All As Specified And Directed By Engr-In-Charge. Make: Legrand / L&T / Schneider. 101 S&F Sheet Metal Enclosures 240 Voltwith Suitable Rated Bus Bar For Double Door 4 Way Ip-43 DbS Mounting Flush On Wall / Concealed And Making Good Distubed Surfaces Incl Taking Out Unserviceable Db Any Capacity. Complete All As Specified And Directed By Engr-In-Charge. Make: Legrand / L&T / Schneider. 102 Supply And Fixing Wall Mounted Type Sheet Metal Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket Complete With And Including Mcb Spn 20 Amp C Series 10 Ka Mounted On Din Rail Channel And Suitable Plug Complete All As Specified And Directed By Engr-In-Charge Make: Legrand Cat No 5078 14 Or Eqvt In L&T / Simens / Schneider. ( Note : Item Rate Including All Items Ie Base Box, Plug, Socket , Mcb Etc Complete ) 103 S&F Mcb Spn240 Volt 10 Ka40 Amp C Series Conforming To Iscomplete All As Specified & Directed.Make: Legrand / L&T / Schneider. 104 S&F Mcb Single Pole240 Volt, 10 Ka, 40 Amp, C Series Confirming To Is Complete All As Specified And Directed.Make: Legrand / L&T / Schneider. 105 M&L For Sub Main Wiringwith 2 Single Core Pvc Insulated Unsheathed Cable 1100 Volts Grade Heavy Duty Copper Conductor Multistranded Of Size 4 Sqmm ( Nominal Area ) Drawing In And Including 20 Mm Dia Or Higher Medium Dutypvc Concealed Conduit And Conduit Accessories And Fittings. Including One Single Core Green Colour Pvc Insulated Unsheathed Cable Copper Conductor Multistranded Of Size 4 Sq Mm As Earth Wire Upto Common Earth And Connected To Earth Dolly Complete Incl Taking Out Old Unserviceable Submain All As Specified & Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Aug-2022 AMENDMENT TO DATE Date 22-08-2022
2 12-Aug-2022 AMENDMENT IN DATE Date 01-09-2022
3 22-Aug-2022 AMENDMENT OF DATE Date 22-09-2022
4 22-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

NAME OF WORK : MAINTENANCE OF SUMMER APPLIANCE INCLUDING REPLACEMENT OF DEFECTIVE SPARES AND ALLIED WORKS OF SUMMER APPLIANCE AND REPAIR/REPLACEMENT OF INTERNAL WIRING INCLUDING FITTING/FIXTURE WITH CONNECTED ACCESSORIES OF AC INSTALLATIONS TUNIR AND OUT SIDE AREA UNDER AGE E/M-II GE (NW) KARANJA
Sl. No. Item Description
1Servicing / Preventive maintenance of the following equipments of different capacitiesby carrying out regular maintenance such aschecking of cooling coils, condensers, electric motors of different types and compressors and other parts, cleaning washing with suitable cleaning agent/chemical using vacuum cleaner, replacement of rubber wheels, bolts & nuts, screws check nuts, PVC sleeves and thimbles,and other parts as required, checking all electrical parts and electrical wiring etc, tightening of electrical connections, greasing of electric motors, checking of gas pressure and gas charging to the desired pressure to ensure serviceability regularily through out the contract period all as specified and as directed.
2(a) 1.5/2.0 Ton capacity window type Acs
3(b)1.5/2.0tons capacity split type ACs
4(c)2.0/3.0tons capacity Casset type ACs
5(d)Water coolers ofany capacity
6(e)Refrigerators capacity 165 to 310 Ltr
7(f)Deep Freezers up to 400 Ltr
8(g)Ice making machine 250 Ltr
9Taking out sealed/ old burnt compressor of window type AC 1.5 ton of approved make and S&F new sealed compressoras per reciprocating type suitable for 1.5 Ton capacity AC and connecting up suction and discharging pipe line with gas welding complete all as specified and directed by Engineer-in-Charge. Make: M/s Kirloskar /M/s Carrier/M/s Voltas/ M/s Bluestar or as approved by GE.
10All as per item No. 2.00 butsplit type AC 1.5 Toncapacity complete all as specified and as directed
11All as per item No. 2.00 but split type AC 2 Toncapacity complete all as specified and as directed.
12Taking down split type AC and taking out rotary type sealed compressor of split type AC 1.5 ton capacity of approved make and S&F new sealed rotary type compressor suitable and discharging pipe line with gas welding and refixing the repaired AC in its original position complete all as specified and directed by Engineer-in-Charge
13All as per item No. 5.00 but split AC 2.0 ton capacity complete all as specified and as directed.
14S & F inrepairs copper cooling coil assembly for 1.5 tonair conditioner of approved makeincluding testing and commissioning complete all as directed by Engineer-in-Charge.
15S & F in repairs of copper cooling coil assembly for 2.0 ton air conditioner of approved Make, commissioning complete all as specified and as directed.
16S & F inrepairscondenser coil assembly suitable for 1.5 tonair conditioner including testing and commissioning complete all as specified and as directed.
17S & F inrepairscondenser coil assembly suitable for 2.0 tonair conditioner including testing and commissioning complete all as specified and directed.
18Supply & fixing in replacementof Unserviceable split type Air conditioner indoor unit suitable for 1.5/2.0 Ton invertor type as per existing make & sizecomplete with remote assy all as specified & directed by Engr-in-charge.Make : Carrier/Hitachi/Voltas/Daikin/Panasonic/Bluestar
19NOTE FOR ITEM NOS 2.00 TO 11.00 :- (a) Contractor will provide Guarantee for at least one year for replaced compressor unit. Compressor should be sealed with original manufacturers packing having reputed make all as approved by Engineer -In -Charge. (b) Gas charging will be measured and paid separately under relevant items as described. Gas charging will be measured and paid only once for entire contract period while initial charging of compressorand subsequent leakage / topping up shall be made good by the contractor at his own cost through out the contract period.
20S & F in repairs running capacitor 36 mfd, 3 pole & 2 pole suitable for 1.5 ton window / split type air conditioner. Make M/s Asian / M/s Unistar / M/s Epcos / M/s Electro all as specified and as directed.
21S & F inrepairsrunning capacitor 45 mfd, 3 pole & 2 pole suitable for 2.0 ton window / split type air conditioner. Make M/s Asian / Ms Unistar M/s Epcos / M/s Electro all as specified and as directed.
22S & F inrepairs starting capacitor 100 to 120 mfd suitable for 1.5 ton window / split type air conditioner. Make M/s Asian / M/s Unistar / M/s Epcos / M/s Electro all as specified and as directed .
23S & F inrepairsstarting capacitor 100 to 150 mfd suitable for 2.0 ton capacity window / split type air conditioners. Make M/s Asian / Ms Unistar M/s Epcos / M/s Electro complete all as specified and as directed.
24S&F in repairs starting relay suitable for 1.5 Ton / 2.0 Ton / 3.0 Ton of Split / Window type AC make M/s Sriram / M/s Renutral all as specified and as directed.
25S & F inrepairsof thermostat switch for window / Split type Air conditioner of 1.5 / 2.0 / 3.0 Ton capacity. Make M/s Renutral / M/s Denfoss all as specified and as directed.
26M & L for gas charging R-22 in window type AC 1.5 ton capacity of approved make and type including pressure testing, leakage, vaccumising, rectification, testing and commissioning complete all as specified and as directed.
27All as per item No 19.00 but 2.0 ton capacity complete all as specified and as directed.
28All as per item No 19.00 but split type AC 1.5 / 2.0 / 3.0 ton capacity complete all as specified and as directed.
29Taking down window type / split type air conditioner of any type / make / capacity from site (either in ground / any floor), transporting to work site opening top and side cover, dismantling all electrical controls and components and cleaning the whole unit with electric blower and spray cleaning with water, descaling with acid in both side of cooling coil and components, refixing the covers and making electrical connections, installation of the machine in same location, testing, commissioning complete all as specified and as as directed.Note :- Spares required for repair will be measured and paid seperately under relevent item of this schedule.
30Shifting of Split type Air Conditioner of any type and make, up to 2 TR from existing location to other location and installingindoor and outdoor units as directed including provision of necessary brackets (L type) clamps, GI nuts, bolts and washers etc for fixing of indoor / outdoor units including topping up of refrigerant gas and Nitrogen pressure test to find out leakage, commissioning and testing and making good disturbed surface complete all as specified & directed.Note : (i) PVC pipe for protection , drain pipe , control cable, extra copper tubing of any sizefor suction / discharge will be measured and paid separately. (ii) Gas charging will be measured and paid only once for entire contract period while initial charging of compressorand subsequent leakage / topping up shall be made good by the contractor at his own cost.
31Shifting of Window type Air Conditioner of any type and make, up to 2 TR from existing location to other location and installingas directed, commissioning and testing including making opening of required size in walls or existing windows of any type, provision of necessary brackets, clamps, GI nuts, bolts and washers etc for fixing of AC,and making good disturbed surface of walls and windows complete all as specified & directed. Note : (i) PVC drain pipe , control cable where required will be measured and paid separately.
32S & F in repairselectric wiring kit (PCB) suitable for 1.5 ton / 2.0 ton Window type / Split type air conditioner of any make and type complete all as specified and as directed. Note: New PCB shall be as per the existing one.
33Supply in replacement Remote assembly cordless as per existing make and size window/split type AC"s as per AC make complete as specified.
34Taking down corroded body base tray etc of Window / Split type ACof 1.5 Ton / 2 Ton capacity and replacement of body base tray etc made out of 18 SWG mild steel and other portion of mild steel sheet of 20 SWG including motor mounting frame fix with nuts and bolts of suitable size and painting with one coat of black enamel paint and necessary insulation complete all as specified and as directed. Note :- Unit rate quoted shall also deemed to include for reassembling.
35S & F inrepairsof fan blade of motor for window type AC of capacity 1.0 ton / 1.5 ton / 2.0 ton of make M/S Asian or equivalent complete all as specified and as directed.
36S & F in repairsblower fan motor for 1.0 ton / 1.5 ton / 2.0 ton capacity air conditioners including testing, complete all as specified and as directed. Make:Blower fan motor shall be as per the existing one.
37S & F inrepairsblower drum suitable for window type AC of capacity 1.0 ton / 1.5 ton / 2.0 ton completeall as specified and as directed. Note: Blower drum shall be as per the existing one.
38S & F inrepairsfront cover grill suitable for window type air conditioner of capacity 1.0 ton / 1.5 ton / 2.0 ton, complete all as specified and as directed
39S & F inrepairsouter cover suitable for window type air conditioner of any capacity complete all as specified and as directed.
40S & F inrepairsblower motor capacitor 4 mfd suitable for 1.5 window type air conditioner complete all as specified and as directed.
41S & F in repairsblower motor capacitor 10 mfd suitable for 1.5 ton split type air conditioner complete all as specified and as directed.
42S & F inrepairsblower motor capacitor 15 mfdsuitable for 2.0 / 3.0 ton split type air conditioner complete all as specified and as directed.
43Supply, fixing, clamping and jointing copper tubing of standard size 1/2, 5/8 for suction line and liquid discharge line of suitable size 1/4 duly insulated with suitable insulation materials including making hole in any type of wall for passing through pipe andmaking good to the disturbed surface as in replacement and colour matching as per existing shade, complete all as specified and as directed.
44Supply and fixing in replacement cable PVC insulatedPVC unsheathed, multistranded, 1100volts grade (ISI marked) 3 core 2.5 Sq mm with flexible copper conductor suitable forSplit type AC and Window type AC complete all as specified and as directed. Make:- Havells, Polycab, Plaza.
45Supply and fixing suitable size PVC pipe, heavy duty for drain out of condensing water of split type air conditioner including cutting of floors or making hole in wall and making good the disturbed portion after laying pipe etc to match the existing surface with original specifications complete all as specified and as directed.
46S & F inrepairssynthetic air filter suitable for split/window type air conditioner any capacity complete all as specified and as directed
47Servicing,cleaning of Solar water heater system by dismantling inlet and outlet connection, washing with suitable cleaning agent castic soda, arresting leakage and refixing the same after replacement of bush, nut, bolts,washers, painting of rusted surfaces if any making serviceable to desired satisfaction level complete all as specified & directed by Engineer-in-Charge.
48WATER COOLERS Taking down sealed compressor of water cooler of approved make of capacity 40/80 ltrs and supply and fixing in replacement company repaired sealed unit CAJ 3612 or AE 4440 of M/s Kirloskar or equivalent and connecting up suction and discharge copper pipe with gas welding pressure testing of leakage rectification, vaccumising and charging the refrigerant gas including testing & commissioning complete all as specified and as directed.
49All as per item No 41.00but capacity 60/120 ltrs complete all as specified and as directed. Make : BPK KCE 461 of M/s Kirloskar or equivalent in PS.
50S & F in replacement starting capacitor 40/60 mfd complete all as specified and as directed. Make - M/s Asian, M/s Unitstar, M/s Tibcon, M/s Telsa
51S & F inrepairsstarting capacitor 80 /100 mfdcomplete all as specified and as directed. Make – M/s Asian, M/s Unistar, M/s Tibcon, M/s Telsa.
52S & F inrepairsof thermostatic switch for water cooler complete all as specified and as directed. Make – M/s Renutral , M/s Ind-foss, M/s Annapurna(AES).
53S&F inrepairs of condenser fan motor 1 / 35 HP 230 volt AC single phase suitable for water cooler all as specified and as directed. Make – M/s Crompton Greaves, M/s Khetan, M/s AVE, M/sFace master.
54All as per item No 46.00but 1 /83 HP complete all as specified and as directed.
55S & F inrepairsrelay for water cooler of capacity 40/80 litres and 60/120 litres capacity all as specified and as directed.
56S&F inrepairsof fan blade suitable for existing water coolerof any capacity, approved make and type complete all as specified and as directed.
57S & F in repairs push cock/lifting cock of 15 mm dia chromium plated suitable for water cooler of capacity 40/80 litres & 60/120 litres complete all as specified and as directed.
58Detecting the gas leakage, rectifying the defects, vacumizing and charging fresh refrigerant gas and commissioing and testing the water cooler of capacity upto60/120 litre capacity , complete all as specified and as directed.
59S & F inrepairs of water tray stainless steelgrade SS 304 of 40 /80 ltr capacity complete all as specified and as directed.
60All as per item No 52.00 but capacity 60/120 Ltrs complete all as specified and as directed.
61S&F inrepairsof rubber packing and hinges of top cover of water cooler of any makeand capacity complete all as specified and as directed.
62S & F in repairs15 mm dia ISI marked float valveBrass of make M/s Prayag/ M/s Rojari or equivalent, all as specified and as directed.
63S & F inrepairsover load protector for watercooler of any capacity complete all as specified and as directed.
64S & F in replacement PVC connecting pipe with brass nuts& washers at both ends oflength not exceeding 60 cm for water connection of water coolers complete all as specified and as directed.
65S & F suitable size PVC drain pipe flexible heavy duty with necessary saddles and fitting for drain out water from water cooler complete all as specified and as directed.
66REFRIGERATORS Taking down sealed compressor of 165Ltr/175 ltrs capacityof refrigerator of approved make and type and replacement of hermetically sealed unit of compressor of samesize and type and capacity , connecting sealed unit and dischargepipe with gas welding and soldering rod complete all specified and as directed.
67All as per item No 59.00 but 286/300/310 ltr capacitycomplete all specified and as directed.
68S & F inrepairs thermostat switch for refrigeratorof any capacity, complete all as specified and as directed.
69S&F inrepairs over load relay/protector suitable for high / low speed refrigerators of unit of compressor 165 /230 /286 /300 / 310 Ltr capacityof refrigerator all as specified and directed. Make: -M/s Renutral / M/s Sriram / M/s Kelvinator / M/s Godrej / M/s Kirloskar
70S&F lamp 15 watt or any watt screw /pin type suitable for approved make and capacity refrigerator complete all as specified and directed by E in Charge. Make: M/s Godrej / M/s Kelvinator.
71M&L for charging of refrigeratorrefrigerant gas R-134a/ R-410a suitable gas after vaccumising / pressure and leaking including flushing the system in the refrigerator of any make of 165 Litre Cap all as specified and as directed. Note:- Gas charging for a particular machine will be measured and paid only once for entire contract period while first/ initial charging and subsequent leakage / topping up shall be made good by the contractor at his own cost.
72All as per item No 64.00but 230 / 286 / 300 /310Ltr capacitycomplete all specified and as directed.
73S & F inrepairsmagnetic gasket for refrigeratorof165/175/286/300 /310 litres capacity all as specified and as directed.
74S & F in repairs relay for refrigeratorof capacity 165 to 310litresall as specified and as directed.
75Supply and fixing in replacement of unservicable freezer chamber existing make & size forupto 165 to 195 Ltr capacity refrigerator direct cool complete all as specified & directed.
76Supply and fixing in replacement of unservicable freezer chamber existing make & size for refrigerator frost free double door incl heater, blower etc for 285 to 310 litres capacity.
77M&L in replacement of unservicable condenser for refrigerator as per existing make &any capacity, complete all as specified and directed.
78M&L for disconnecting the electrical and refrigerant connections of defective compressor unit ofdeep freezer of capacity upto 400 Ltrsand replacing with new compressor (refurbrished by OEM), connectingthe sealed unit both electrical and refrigerant connections including charging refrigerant gas after nitrogen pressure test to find out leakage as requiredcomplete all as specified & directed. Make of Compressors : Kirloskar Complan/ Tecumseh/Carrier.
79Supply & fixing in replacementof unservicable condenser fan motor box typefor Deep freezer of any capacity/size, complete all as specified and directed. Make – M/s Crompton Greaves, M/s Khetan, M/s AVE, M/sFace master.
80Aircurtains Taking down defective/unserviceable air curtain of existing capacity and existing make, transporting to company authorized outlet, collecting company repaired air curtain of same make and transporting back to site, refixing at original posotion complete including testing and commissioning the machine onto the mounting plate and ensure the safety than fix it tighten with screw complete all as specified and directed by Engr in charge.
81M&L for replacement ofwater purifier filter kit including repair/ replacement of defective parts such as filters, solenoide valve, pump, switch complete of machine all as directed by Engr-in-charge.
82M& L for repair of voltage stabilizer of capacity 5 KVA including replacement of burnt out transformer and all accessories complete all as directed by Engr-in-charge
83INTERNAL ELECTRIFICATION Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, lamp holders, regulators, sockets, light fitting any type etc complete. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Eng.-in-charge
84Taking down MCB with sheet metal enclosure, main switch, DB etc and making good disturbed surfaces to match with existing surfaces.
85Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces
86M&L for Point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multistranded copper conductor single core FRLS cable drawn through and including non metallic medium duty rigid PVCconduit (medium duty)20mm dia or higher size complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including pressed iron/steel suction boxof thickness1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly complete all as specified and directed by Engr.-in-charge of following.
87(a) One light /bell / Exhaust fan pointcontrolled by one-one way switch.
88(b) One ceiling fan Point controlled by one-one way switch through Regulator.
89(c) One three pin 5 Amp socket on same board with other switches.
90(d) One three pin 5 Amp socket on independent board.
91All as per item No.79 above but with 2.5 Sqmm. (nominal area) wire/cable for phase and neutral for one 3 Pin 15 amp socket on independent board including one 1.5 sqmm PVC insulated unsheathed multi stranded copper conductor cable, FRLS 1100 volts grade as earth continuity conductor upto common earth & connected to earth dolly complete all as specified and directed by Eng.-in-charge.
92S&F switch piano flush, button type 5 Amp SP 250 Volt AC complete all as specified & directed.
93S&F switch piano flush button type 15 Amps SP 250 VoltAC complete all as specified & directed.
94S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
95S&F socket outlet 2-in1,3 pin 5 and 15 Amp flush type 250V AC complete all as specified & directed.
96S&F ceiling rose surface bakelite 3 terminals of size 65x25mm. complete .
97S&F step type, electronic fan regulator 120 watts, 5 step for ceiling fan 1200/1400 mm sweep 230 volts AC.
98S&F lamp holder PVC/polycarbonate type with LED lamp 9/10 watt complete all as specified & directed.
99S&F wall mounted LED tube light fitting 1x20/22 watts extruded aluminiumpolycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 3000 K/6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed.
100S&F sheet metal enclosures 240 voltwith suitable rated bus bar for double door 8 way IP-43 DB"s mounting flush on wall/concealed and making good distubed surfaces incl taking out Unserviceable DB any capacity. complete all as specified and directed by Engr-in-charge. Make: Legrand/ L&T/ Schneider.
101S&F sheet metal enclosures 240 voltwith suitable rated bus bar for double door 4 way IP-43 DB"s mounting flush on wall/concealed and making good distubed surfaces incl taking out Unserviceable DB any capacity. complete all as specified and directed by Engr-in-charge. Make: Legrand/ L&T/ Schneider.
102Supply and fixing wall mounted type sheet metal single pole and neutral enclosure with a two pin and earth plug and socket complete with and including MCB SPN 20 Amp "C" series 10 KA mounted on DIN rail channel and suitable plug complete all as specified and directed by Engr-in-charge Make: Legrand Cat No 5078 14 or eqvt in L&T /Simens/ Schneider. (Note : Item rate including all items ie base box, plug, socket , MCB etc complete)
103S&F MCB SPN240 Volt 10 KA40 Amp "C" series conforming to IScomplete all as specified & directed.Make: Legrand/L&T/Schneider.
104S&F MCB single pole240 volt, 10 KA, 40 Amp, "C" series confirming to IS complete all as specified and directed.Make: Legrand/L&T/Schneider.
105M&L for sub main wiringwith 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sqmm (nominal area) drawing in and including 20 mm dia or higher medium dutyPVC concealed conduit and conduit accessories and fittings. Including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 4 Sq mm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail