Provision Of Led Bldg Security Lights In Md Accn Phase Ii Area Provn Exhaust Fan In Key Person Quarter Provn Of Smart Meters In Offcrs Accn Provn Of Geysers In Jco Or Md Accn Under Ge Narangi, narangi-Assam

Military Engineer Services-MES has published Provision Of Led Bldg Security Lights In Md Accn Phase Ii Area Provn Exhaust Fan In Key Person Quarter Provn Of Smart Meters In Offcrs Accn Provn Of Geysers In Jco Or Md Accn Under Ge Narangi. Submission Date for this Tender is 15-08-2022. LED Light Tenders in narangi Assam. Bidders can get complete Tender details and download the document.




Tender Notice

33231168
Corrigendum : Provision Of Led Bldg Security Lights In Md Accn Phase Ii Area Provn Exhaust Fan In Key Person Quarter Provn Of Smart Meters In Offcrs Accn Provn Of Geysers In Jco Or Md Accn Under Ge Narangi
Open Tender
Indian
Assam
narangi
15-08-2022

Tender Details

Provision Of Led Bldg Security Lights In Md Accn Phase Ii Area Provn Exhaust Fan In Key Person Quarter Provn Of Smart Meters In Offcrs Accn Provn Of Geysers In Jco Or Md Accn Under Ge Narangi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-08-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 99700.0 /-
Tender Value
INR 49.85 Lakhs /-

BOQ Items

Name of Work : PROVN OF LED BLDG SECURITY LIGHTS IN MD ACCN PHASE-II AREA, PROVN EXHAUST FAN IN KEY PERSON QUARTER, PROVN OF SMART METERS IN OFFCRS ACCN & PROVN OF GEYSERS IN JCO/ OR MD ACCN UNDER GE NARANGI
Sl. No. Item Description
1SCHEDULE "A" PART-I
2M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLS cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
3M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLS cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC gray conduit of 20mm dia on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan point controlled by two number two way 5 Amp switch complete all as specified and as directed.
4S&F switch piano, flush type single pole one way 5 Amps 230 volt complete all as directed.
5S&F switch piano, flush type single pole two way 5 Amps 230 volt complete all as directed.
6S&F ceiling rose surface bakelite 65x50mm three terminal complete all as directed.
7S&F switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp PVC type complete all as directed. .
8S &F street light fitting of 60 Watt LED made ofpressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protectionand lens embedded PC Cover having top opening seperate driver compartment,should have luminaire efficacy =110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5500,IP66,impact resistance IK 07 ,inbuiltprotection against lightning , over voltage , short circuit and surge/spike protection device upto5 KV complete also tested for 440 Volt for 8 hour Phase to phase without any damageincluding taking down oldlight fittings complete allas specified and as directed. (Make:Havells Cat Part No. ENDURAPEARLNEOSL60WLED757PASYTOPCor equivalent in Philips/Bajaj/Crompton )
9Supply and fixing in repairs street light bracket made of GI pipe 40 mm bore light grade (bend to shape), 2.0 metre longand fixed with and including 2 sets of MS flat iron clamp (clamp shall be 40 X 5mm ), nuts, bolts and washers on pole complete all as specified and directed.
10S&FMCBs, SP 6 to 32 Amps, 10 KA, "C" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :-Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T
11S&F of Exhaust fans AC single phase 230/ 240 V ,50 Hz metallic heavy body of size 300 mm sweep, 1400 RPMwith louver fixing with 4 no hold fastener nut and bolt with washer and connecting with flexiable PVC insulated multistranded copper conductor cable of size 1.5 sqmm including civil work opening on wall and making good surface complete all asspecified and directed. (Make-USHA / Havells/Bajaj /Crompton)
12S&F Smart three phase four wire single source prepaid energy meters BIS 15884 marked in existing meter board/floor panels with pre payment capacity touch keypad based digitial having current range 10-60 Amp 415 Volt accuracy class 1.0 alongwith parallel home unit with inbuilt load control switch containing display split provision for TOD and RTC, inbuilt feature to sense single source registration with respect to grid and dynamic load allocation facility from grid capable to define for tariff slabs, happy hours and holiday definition complete all as specified and directed.Make-L&T/HPL or equivalent Note-Unit rate quoted by the contractor is deemed to be impesive of fees for 05 (Five) years server maintenance. The distance between home unit and meter will be approx 20 to 30 meter.
13Fixing only old serviceable meter with necessary connection to the different location as directed by the Engg-In-Charge complete. (Note: Old Serviceable Meter obtained from item No. 11 here-in-above.)
14M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.)
15M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.)
16M&L for Sub main wiring with 2 runs of 2.5 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 2.5 Sqmm cable and 1 run of 2.5 Sqmm cable along with conduit altogether shall be measured as one unit.)
17S&F of Meter Box, anticorrosive, dust & vermin proof, shock proof, self extingushing property, heat resistant, water proof Ultra Violet Stabilized and pilfer resistant to accommodate 4 Nos three phase pre-paid meter, made out of Thermosetting Plastic ie Glass Reinforced Polyester Steet Moulding Compound (SMC) confirming to IS: 13947 (1992) and IS: 14722:2000 etc. including taking down the old one complete all as specified and as directed.
18Supply and fixing in repairs modular north west outlet tiny trip C-25, 2 pole MCB 240 V 50Hz single phase motor startar current range from 11 Amp to 18 Amp 240V 50 Hz AC including top complete all as specified and directed.
19Supply, fixing and testing of vertical wall mounted Storage type electric water heater of capacity 25 ltrs with BEE 5 star rated, 230 V, maximum power consumption 2 KW, Drypowder Fero Glass coating Technology for inner container with Heavy Duty seamless Incoloy 800 Glass lined heating element, and 2 Nos PVC connecting pipe of whirl technology 15 mm bore 450mm long for hot and cold water supply complete with all accesories and all as specified and directed by the Engr-In-Charge.(Make: Jaquar Model: MET-WHT-V025 / HAVELLS Model: Puro, or equivalent Model in USHA ).
20S & F GI tubing15 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
21Cutting existing steel tubing 15mm dia for addition / insertion of new Tee / Elbows / Socket etc. (Each cut measured) by screwing existing pipe line complete all as specified and as directed.
22S&F of Bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed.
23S&F in repair, 15mm dia stop valves stop cast copper alloy, fancy type, chromium plated with long shank and cup ( concealed type) complete all as specified and as directed.